Andy McFadden
b65f75437d Make local variable prefix configurable for display
It's kind of handy to have variable labels tagged.  This makes it
configurable.  The quick-set for Merlin sets it to "]", all others
leave it blank.
2019-08-31 15:00:45 -07:00
Andy McFadden
7bbe5692bd Add C64 encodings to instruction and data operand editors
Both dialogs got a couple extra radio buttons for selection of
single character operands.  The data operand editor got a combo box
that lets you specify how it scans for viable strings.

Various string scanning methods were made more generic.  This got a
little strange with auto-detection of low/high ASCII, but that was
mostly a matter of keeping the previous code around as a special
case.

Made C64 Screen Code DCI strings a thing that works.
2019-08-15 17:53:12 -07:00
Andy McFadden
beb1024550 Define and use "delimiter sets"
A delimiter definition is four strings (prefix, open, close, suffix)
that are concatenated with the character or string data to form an
operand.  A delimiter set is a collection of delimiter definitions,
with separate entries for each character encoding.

This is a convenient way to configure Formatter objects, import and
export data from the app settings file, and manage the UI needed to
allow the user to customize how things look.

The full set of options didn't fit on the first app settings tab, so
there's now a separate tab just for specifying character and string
delimiters.  (This might be overkill, but there are various plausible
scenarios that make use of it.)

The delimiters for on-screen display of strings can now be
configured.
2019-08-14 16:10:04 -07:00
Andy McFadden
068b3a44c7 Remove "high" versions of string pseudo-ops
High ASCII and other encodings will be noted in the operand field,
not the opcode, so we no longer need these.

This removes the six input fields from the Pseudo-Op tab of app
settings.  Values were stored as a serialized class in settings,
which generally works correctly as far as forward/backward
compatibility goes, so no worries there.

This also adds four "delimiter pattern" fields to the Code View tab,
allowing the user to customize how encoded strings are marked up
for the code list.  The values aren't actually used yet.

Also, fixed an issue where changes to text fields on the Pseudo-Op
tab weren't raising the dirty flag.
2019-08-11 16:44:22 -07:00
Andy McFadden
c64f72d147 Move WPF code from SourceGenWPF to SourceGen 2019-07-20 13:28:37 -07:00
Andy McFadden
e3906e021b Move WinForms code to SourceGenWF 2019-07-20 13:02:54 -07:00
Andy McFadden
97a372a884 Add selectable auto-label styles
SourceGen creates "auto" labels when it finds a reference to an
address that doesn't have a label associated with it.  The label for
address $1234 would be "L1234".  This change allows the project to
specify alternative label naming conventions, annotating them with
information from the cross-reference data.  For example, a subroutine
entry point (i.e. the target of a JSR) would be "S_1234".  (The
underscore was added to avoid confusion when an annotation letter
is the same as a hex digit.)

Also, tweaked the way the preferred clipboard line format is stored
in the settings file (was an integer, now an enumeration string).
2019-04-15 15:14:04 -07:00
Andy McFadden
96ee33ae8c Optionally add spaces in the "bytes" column
Affects the display list and copy/paste text.  Makes the column
three spaces wider, but makes it easier to read.
2018-10-21 21:08:48 -07:00
Andy McFadden
4f9af30455 Progress toward new assembler configuration
Rather than have each assembler get its own app config string for
the cross-assembler executable, we now have a collection of per-
assembler config items, of which the executable path name is one
member.  The Asm Config tab has an auto-generated pop-up to select
the assembler.

The per-assembler settings block is serialized with the rather
unpleasant JSON-in-JSON approach, but nobody should have to look
at it.

This also adds assembler-specific column widths to the settings
dialog, though they aren't actually used yet.
2018-10-20 20:35:32 -07:00
Andy McFadden
78906dcf58 Record main window location as well as size
If the main window was maximized before, maximize it when we
restart.

Changed the preferences to record the width of the right panels,
rather than the splitter distance, which is actually the width of
the middle of the screen.

Seems to work correctly on my non-uniform multi-monitor setup.  I
added a check to confirm that the middle of the title bar falls in
the working area of the screen that WinForms thinks we're in, so it
shouldn't be possible to "lose" a window off the edge by dragging
it or by changing screen resolutions.
2018-10-01 15:04:23 -07:00
Andy McFadden
2c6212404d Initial file commit 2018-09-28 10:05:11 -07:00