1
0
mirror of https://github.com/TomHarte/CLK.git synced 2024-11-04 15:05:36 +00:00
CLK/OSBindings/Mac/Clock SignalTests/6532Tests.swift

155 lines
4.7 KiB
Swift
Raw Normal View History

//
// 6532Tests.swift
// Clock Signal
//
// Created by Thomas Harte on 19/06/2016.
// Copyright © 2016 Thomas Harte. All rights reserved.
//
import XCTest
import Foundation
class MOS6532Tests: XCTestCase {
2016-09-16 02:12:12 +00:00
fileprivate func with6532(_ action: (MOS6532Bridge) -> ()) {
let bridge = MOS6532Bridge()
action(bridge)
}
// MARK: Timer tests
func testOneTickTimer() {
with6532 {
// set a count of 128 at single-clock intervals
$0.setValue(128, forRegister:0x14)
// run for one clock and the count should now be 127
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 1)
XCTAssert($0.value(forRegister: 4) == 127, "A single tick should decrease the counter once")
// run for a further 200 clock counts; timer should reach -73 = 183
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 200)
XCTAssert($0.value(forRegister: 4) == 183, "Timer should underflow and keep counting")
}
}
// TODO: the tests below makes the assumption that divider phase is flexible; verify
func testEightTickTimer() {
with6532 {
// set a count of 28 at eight-clock intervals
$0.setValue(28, forRegister:0x15)
// run for seven clock and the count should still be 28
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 7)
XCTAssert($0.value(forRegister: 4) == 28, "The timer should remain unchanged for seven clocks")
// run for a further clock and the count should now be 27
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 1)
XCTAssert($0.value(forRegister: 4) == 27, "The timer should have decremented once after 8 cycles")
// run for a further 7 + 27*8 + 5 = 228 clock counts; timer should reach -5 = 0xfb
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 228)
XCTAssert($0.value(forRegister: 4) == 0xfb, "Timer should underflow and start counting at single-clock pace")
// timer should now resume dividing by eight
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 7)
XCTAssert($0.value(forRegister: 4) == 0xfb, "Timer should remain unchanged for seven cycles")
// timer should now resume dividing by eight
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 1)
XCTAssert($0.value(forRegister: 4) == 0xfa, "Timer should decrement after eighth cycle")
}
}
func testTimerInterrupt() {
with6532 {
// set a count of 1 at single-clock intervals
$0.setValue(1, forRegister:0x1c)
// run for one clock and the count should now be zero
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 1)
// interrupt shouldn't be signalled yet, bit should not be set
XCTAssert(!$0.irqLine, "IRQ line should not be set")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x00, "Counter interrupt should not be set")
// run for one more clock
2016-09-16 02:12:12 +00:00
$0.run(forCycles: 1)
// the interrupt line and bit should now be set
XCTAssert($0.irqLine, "IRQ line should be set")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x80, "Counter interrupt should be set")
// writing again to the timer should clear both
$0.setValue(1, forRegister:0x1c)
XCTAssert(!$0.irqLine, "IRQ line should be clear")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x00, "Counter interrupt should not be set")
}
}
// MARK: PA7 interrupt tests
func testPA7InterruptDisabled() {
with6532 {
// disable edge detection
$0.setValue(0, forRegister:4)
// set output mode for port a
$0.setValue(0xff, forRegister:1)
// toggle bit 7 of port a in both directions
$0.setValue(0x80, forRegister:0)
$0.setValue(0x00, forRegister:0)
$0.setValue(0x80, forRegister:0)
// confirm that the interrupt flag is set but the line is not
XCTAssert(!$0.irqLine, "IRQ line should not be set")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x40, "Timer interrupt bit should be set")
// reading the status register should have reset the interrupt flag
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x00, "Timer interrupt bit should be reset")
}
}
func testPA7LeadingEdge() {
with6532 {
// seed port a is high; ensure interrupt bit is clear
$0.setValue(0x00, forRegister:0)
2016-09-16 02:12:12 +00:00
$0.value(forRegister: 5)
// enable leading edge detection
$0.setValue(0, forRegister:7)
// set output mode for port a
$0.setValue(0xff, forRegister:1)
// toggle bit 7 of port a in a leading direction
$0.setValue(0x80, forRegister:0)
// confirm that both the interrupt flag are the line are set
XCTAssert($0.irqLine, "IRQ line should be set")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x40, "Timer interrupt bit should be set")
}
}
func testPA7TrailingEdge() {
with6532 {
// seed port a is high; ensure interrupt bit is clear
$0.setValue(0x80, forRegister:0)
2016-09-16 02:12:12 +00:00
$0.value(forRegister: 5)
// enable trailing edge detection
$0.setValue(0, forRegister:6)
// set output mode for port a
$0.setValue(0xff, forRegister:1)
// toggle bit 7 of port a in a rising direction
$0.setValue(0x00, forRegister:0)
// confirm that both the interrupt flag are the line are set
XCTAssert($0.irqLine, "IRQ line should be set")
2016-09-16 02:12:12 +00:00
XCTAssert($0.value(forRegister: 5) == 0x40, "Timer interrupt bit should be set")
}
}
}