mirror of
https://github.com/TomHarte/CLK.git
synced 2025-04-05 04:37:41 +00:00
Copies in notes for required test functions.
This commit is contained in:
parent
dd963d6161
commit
a5f0761a43
@ -125,4 +125,107 @@ class MOS6522Tests: XCTestCase {
|
||||
XCTAssert($0.value(forRegister: 0) == 0x8a, "Data direction register should mix input and output; got \($0.value(forRegister: 0))")
|
||||
}
|
||||
}
|
||||
|
||||
func testShiftDisabled() {
|
||||
/*
|
||||
Mode 0 disables the Shift Register. In this mode the microprocessor can
|
||||
write or read the SR and the SR will shift on each CB1 positive edge
|
||||
shifting in the value on CB2. In this mode the SR Interrupt Flag is
|
||||
disabled (held to a logic 0).
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftInUnderT2() {
|
||||
/*
|
||||
In mode 1, the shifting rate is controlled by the low order 8 bits of T2
|
||||
(Figure 22). Shift pulses are generated on the CB1 pin to control shifting
|
||||
in external devices. The time between transitions of this output clock is a
|
||||
function of the system clock period and the contents of the low order T2
|
||||
latch (N).
|
||||
|
||||
The shifting operation is triggered by the read or write of the SR if the
|
||||
SR flag is set in the IFR. Otherwise the first shift will occur at the next
|
||||
time-out of T2 after a read or write of the SR. Data is shifted first into
|
||||
the low order bit of SR and is then shifted into the next higher order bit
|
||||
of the shift register on the negative-going edge of each clock pulse. The
|
||||
input data should change before the positive-going edge of the CB1 clock
|
||||
pulse. This data is shifted into shift register during the 02 clock cycle
|
||||
following the positive-going edge of the CB1 clock pulse. After 8 CB1 clock
|
||||
pulses, the shift register interrupt flag will set and IRQ will go low.
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftInUnderPhase2() {
|
||||
/*
|
||||
In mode 2, the shift rate is a direct function of the system clock
|
||||
frequency (Figure 23). CB1 becomes an output which generates shift pulses
|
||||
for controlling external devices. Timer 2 operates as an independent
|
||||
interval timer and has no effect on SR. The shifting operation is triggered
|
||||
by reading or writing the Shift Register. Data is shifted, first into bit 0
|
||||
and is then shifted into the next higher order bit of the shift register on
|
||||
the trailing edge of each 02 clock pulse. After 8 clock pulses, the shift
|
||||
register interrupt flag will be set, and the output clock pulses on CB1
|
||||
will stop.
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftInUnderCB1() {
|
||||
/*
|
||||
In mode 3, external pin CB1 becomes an input (Figure 24). This allows an
|
||||
external device to load the shift register at its own pace. The shift
|
||||
register counter will interrupt the processor each time 8 bits have been
|
||||
shifted in. However the shift register counter does not stop the shifting
|
||||
operation; it acts simply as a pulse counter. Reading or writing the Shift
|
||||
Register resets the Interrupt Flag and initializes the SR counter to count
|
||||
another 8 pulses.
|
||||
|
||||
Note that the data is shifted during the first system clock cycle
|
||||
following the positive-going edge of the CB1 shift pulse. For this reason,
|
||||
data must be held stable during the first full cycle following CB1 going
|
||||
high.
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftOutUnderT2FreeRunning() {
|
||||
/*
|
||||
Mode 4 is very similar to mode 5 in which the shifting rate is set by T2.
|
||||
However, in mode 4 the SR Counter does not stop the shifting operation
|
||||
(Figure 25). Since the Shift Register bit 7 (SR7) is recirculated back into
|
||||
bit 0, the 8 bits loaded into the Shift Register will be clocked onto CB2
|
||||
repetitively. In this mode the Shift Register Counter is disabled.
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftOutUnderT2() {
|
||||
/*
|
||||
In mode 5, the shift rate is controlled by T2 (as in mode 4). The shifting
|
||||
operation is triggered by the read or write of the SR if the SR flag is set
|
||||
in the IFR (Figure 26). Otherwise the first shift will occur at the next
|
||||
time-out of T2 after a read or write of the SR. However, with each read or
|
||||
write of the shift register the SR Counter is reset and 8 bits are shifted
|
||||
onto CB2. At the same time, 8 shift pulses are generated on CB1 to control
|
||||
shifting in external devices. After the 8 shift pulses, the shifting is
|
||||
disabled, the SR Interrupt Flag is set and CB2 remains at the last data
|
||||
level.
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftOutUnderPhase2() {
|
||||
/*
|
||||
In mode 6, the shift rate is controlled by the 02 system clock (Figure 27).
|
||||
*/
|
||||
}
|
||||
|
||||
func testShiftOutUnderCB1() {
|
||||
/*
|
||||
In mode 7, shifting is controlled by pulses applied to the CB1 pin by an
|
||||
external device (Figure 28). The SR counter sets the SR Interrupt Flag each
|
||||
time it counts 8 pulses but it does not disable the shifting function. Each
|
||||
time the microprocessor, writes or reads the shift register, the SR
|
||||
Interrupt Flag is reset and the SR counter is initialized to begin counting
|
||||
the next 8 shift pulses on pin CB1. After 8 shift pulses, the Interrupt
|
||||
Flag is set. The microprocessor can then load the shift register with the
|
||||
next byte of data.
|
||||
*/
|
||||
}
|
||||
}
|
||||
|