1
0
mirror of https://github.com/TomHarte/CLK.git synced 2024-11-03 08:05:40 +00:00
Commit Graph

2200 Commits

Author SHA1 Message Date
Thomas Harte
7898f643ac Added bus request/acknowledge logic. 2017-06-03 19:09:47 -04:00
Thomas Harte
7bd45d308a Error was simply failure of the interrupt-mode setter. Fixed. 2017-06-03 18:58:13 -04:00
Thomas Harte
b3da16911f Tweaked timing of mode 0, per contradictory information. Wrote a failing test of mode 2. 2017-06-03 18:42:54 -04:00
Thomas Harte
e52892f75b Added a test of interrupt mode 1. 2017-06-03 18:16:13 -04:00
Thomas Harte
8c41a0f0ed Added a test to confirm interrupts are disabled, and a response to the interrupt cycle within the all-RAM machine. 2017-06-03 17:53:44 -04:00
Thomas Harte
3e9212aaff Plumbed through to allow interrupt tests, wrote an NMI test, corrected the error revealed. 2017-06-03 17:41:45 -04:00
Thomas Harte
a2ec902773 Made an attempt at implementing all three modes of IRQ. 2017-06-03 17:07:05 -04:00
Thomas Harte
1c0130fd02 Cleaned up with a macro, and decided to make absolutely sure that DecodeOperation is functioning as intended by removing the MoveToNextProgram from fetch-decode-execute. 2017-06-03 12:19:25 -04:00
Thomas Harte
3e3d6f97f4 Edged towards being able to implement interrupt mode 0: created a special-case micro-op for incrementing the PC, and formalised that DecodeOperation is a terminal operation. 2017-06-03 12:16:21 -04:00
Thomas Harte
9c3bda0111 Attempted to round out NMI handling. 2017-06-03 11:30:12 -04:00
Thomas Harte
d14902700a Minor syntax and wiring fixes. 2017-06-01 22:33:05 -04:00
Thomas Harte
c95c32a9fe Implemented the reset line program and disabled fictitious automatic power-on reset for the Z80 test machine. 2017-06-01 22:31:04 -04:00
Thomas Harte
35e045d7a7 Made a first attempt at the correct segue into the three main kinds of interrupt, though the programs aren't written yet. So undefined behaviour would abound were an interrupt to occur. But it lets me figure out what effect the check has on performance. I hope little. 2017-06-01 22:16:22 -04:00
Thomas Harte
084e1f3d51 Added a latching of interrupt status before each bus operation, and reset and power-on inputs. 2017-06-01 21:40:08 -04:00
Thomas Harte
5b43cefb85 Started filling an appropriate mask variable with the interrupt request status right now. Which is step one towards implementing interrupts. 2017-06-01 20:34:52 -04:00
Thomas Harte
aab637c9e7 Made check_address_for_trap inlineable. 2017-06-01 18:28:34 -04:00
Thomas Harte
7d9b197383 Pulled the .get() call for fetch-decode-execute out of the main loop. 2017-06-01 18:28:04 -04:00
Thomas Harte
c9dd267ec1 Sketched an interface for signalling interrupts and pulled out some of the repetition in flag setting from ADD/ADC/SUB/SBC/CP. 2017-05-31 22:51:32 -04:00
Thomas Harte
a5254989f8 Rewired the Z80 not to use the program queue, as it's not proven a useful abstraction in practice and doing so yields an immediate 22% speed increase. 2017-05-31 20:15:56 -04:00
Thomas Harte
494ce073b5 Tests having been fixed by instating proper Z80 cycle counting, removed caveman logging. 2017-05-31 19:58:57 -04:00
Thomas Harte
b99e4210ba Eliminated pointless abstraction; I ended up going indirect on instruction pages rather than scheduling methods. 2017-05-31 19:57:03 -04:00
Thomas Harte
d3b74cbc91 Set proper initial value for number_of_cycles_. 2017-05-31 19:55:51 -04:00
Thomas Harte
5ff73faf48 Ensured Zexall can pass. 2017-05-31 19:55:06 -04:00
Thomas Harte
2f7f11e2e5 Added diagnosis props. 2017-05-31 06:54:25 -04:00
Thomas Harte
5119997122 Made an attempt, flawed so far, to find a neat way for processor subclasses to offer bus management as an inline function. 2017-05-30 22:41:23 -04:00
Thomas Harte
b5c1773d59 Eliminated another conditional. Albeit a very predictable one. 2017-05-30 22:15:43 -04:00
Thomas Harte
dfb5057342 Moved repetition group conditions explicitly into the switch statement. 2017-05-30 22:12:10 -04:00
Thomas Harte
7bddd294c9 Resolved an unpredictable conditional and temporarily disabled the Zexalltest as part of the default suite, since it takes so long to run. 2017-05-30 21:03:02 -04:00
Thomas Harte
01f7394f7f Corrected 6502 scheduling when flushing the pipeline. 2017-05-30 20:58:07 -04:00
Thomas Harte
5aa8b03349 Attempted to regularise the 6502 with the Z80 as to scheduling. I think that at least one bug remains. 2017-05-30 20:36:53 -04:00
Thomas Harte
b5ad910b81 Merge branch 'Z80' into StraightPointer 2017-05-30 19:25:38 -04:00
Thomas Harte
da65bae86e Switched to supplying the bus operation by reference, go guarantee that it isn't null. 2017-05-30 19:24:58 -04:00
Thomas Harte
a0189a6fe1 Switched to following the current program via address. 2017-05-30 18:49:40 -04:00
Thomas Harte
244b5ba3c2 Added a proper termination condition for Zexall and, for now, a Mhz counter. 2017-05-30 18:32:38 -04:00
Thomas Harte
960de7bd7b Marginally reduced test machine costs based on usage. 2017-05-30 11:59:07 -04:00
Thomas Harte
c6185baa99 Fixed R incrementation and attempted to make the status flags cheaper to write to. 2017-05-29 22:23:19 -04:00
Thomas Harte
4d4695032c Discovered that Zexall is just really slow. Disabled the address sanitiser, and started working towards a verifiable end. 2017-05-29 21:46:00 -04:00
Thomas Harte
9d29cefe75 Evicted manual memory management. 2017-05-29 21:44:33 -04:00
Thomas Harte
35f535b9a3 Noodled around with initial state. 2017-05-29 19:25:08 -04:00
Thomas Harte
6d22f6fcd5 Having decided the bus operation error on 10 is probably in the test cases, decided to allow myself to skip that one comparison. Back to zero failing cases, and with no more useful information to derive from the FUSE test set for the time being. 2017-05-29 17:17:17 -04:00
Thomas Harte
8bfaa487ce Improved logging of bus operations and corrected placement of the OUT step in that repetition group; was otherwise outputting the wrong side of the B adjustment and therefore to the wrong port (if interpreted as 16 bit). 2017-05-29 17:13:24 -04:00
Thomas Harte
0d067d2f01 Adjusted OTI/etc timing; 23 failures outstanding. 2017-05-29 16:54:45 -04:00
Thomas Harte
d66755fd1e Corrected INI/D[r] timing. Down to 45 failures. 2017-05-29 16:50:52 -04:00
Thomas Harte
267b2add9a Adjusted for where FUSE nominally places timestamps. Down to 92 failures. 2017-05-29 16:44:07 -04:00
Thomas Harte
d290e3d99e Corrected simple logging error. Which mysteriously moves me all the way up to 117 failures (!) 2017-05-29 16:35:00 -04:00
Thomas Harte
a6a4c5a936 Made an attempt to introduce checking of bus activity against the FUSE tests. Appears to suggest 54 new failures. 2017-05-29 15:57:27 -04:00
Thomas Harte
8a8f0cef20 With all intentional opcode entry points now covered, commuted XX into NOP to give proper meaning to otherwise undefined codes. 2017-05-29 12:25:10 -04:00
Thomas Harte
91dc0d5f4a Adjusted HALT to issue never-ending M1 fetches on the next instruction. 2017-05-29 12:20:33 -04:00
Thomas Harte
ed7b07c8b1 Made an attempt to implement HALT as an operation that merely leaves the PC in place, adding the Z80's output line. Included that flag in FUSE tests. Discovered that it does not think that HALT acts that way. Which is probably correct. 2017-05-29 11:54:27 -04:00
Thomas Harte
3f880fa769 Fixed [FD/DD][74/75], which always store H or L, never IXh, IXl, IYh or IYl. 2017-05-29 11:44:26 -04:00