1
0
mirror of https://github.com/TomHarte/CLK.git synced 2024-11-19 08:31:11 +00:00
Commit Graph

204 Commits

Author SHA1 Message Date
Raphaël Zumer
71ac26944d Correct typos in Z80.hpp 2019-04-19 17:44:52 -04:00
Thomas Harte
0b771ce61a Removes all instances of the copyright symbol. 2018-05-13 15:19:52 -04:00
Thomas Harte
23c47e21de Proceeds the ColecoVision to booting. 2018-02-24 18:14:38 -05:00
Thomas Harte
6e1d69581c Eliminates a variety of end-of-line spaces. 2017-11-07 22:54:22 -05:00
Thomas Harte
b034d4e6f8 Refactors the Z80 to separate out interface and implementation.
Following the pattern just established by the 6502, puts all implementation specifics beyond the visibility of a human reading Z80.hpp and in subfolders so as to promote the idea that they shouldn't go out of their way.
2017-09-01 20:50:24 -04:00
Thomas Harte
57bfec285f Makes it optional whether the Z80 supports the wait line. If the wait line isn't in use, runtime costs are decreased because the optional wait cycles need not be iterated over. 2017-08-26 23:08:57 -04:00
Thomas Harte
fa19e2d9c2 Removes some detritus. 2017-08-24 22:00:21 -04:00
Thomas Harte
95d360251d Makes all of PartialMachineCycle const, with the exception of the target of *value, since that's intended to be writeable by recipients. 2017-08-24 21:32:33 -04:00
Thomas Harte
7af3de010e Suspected my mode 1 interrupt timing might be off. Reminded myself of the sources. Persuaded myself that it wasn't. Added appropriate comments. 2017-08-23 22:25:31 -04:00
Thomas Harte
e1aded0d95 Allows Z80 users to opt out of support for the bus request line. Which both now do. 2017-08-21 20:43:12 -04:00
Thomas Harte
6315c22b80 Removed repeated checking of bus_request_line_. It's now checked only after each outward perform_machine_cycle. 2017-08-20 12:39:45 -04:00
Thomas Harte
039811ce6a Switched the Z80 to being something a machine has, not something a machine is. 2017-08-02 22:09:59 -04:00
Thomas Harte
4abd62e62b Standardises on const [Half]Cycles as the thing called and returned, rather than const [Half]Cycles & as it's explicitly defined to be only one int in size, so using a reference is overly weighty. 2017-07-27 22:05:29 -04:00
Thomas Harte
8848ebbd4f Formalised set_interrupt_line's optional parameter as being a count of HalfCycles; corrected PartialMachineCycle.is_wait and effected the proper timing for counter reset on a ZX81. 2017-07-27 21:10:14 -04:00
Thomas Harte
37950143fc Attempted to nudge wait timing onto half-cycle boundaries, which expands the number of partial machine cycles the Z80 can post but pleasingly also regularises them. Switched the AllRAMProcessor to reporting half cycles by default and corrected all Z80 tests. 2017-07-27 20:17:13 -04:00
Thomas Harte
60e374dca3 Merge branch 'master' into Memptr 2017-07-27 07:54:25 -04:00
Thomas Harte
8361756dc4 Switched definitively to the works-for-now approach of requiring an explicit opt-in where somebody wants to clock a whole-cycle receiver from a half-cycle clock. 2017-07-27 07:40:02 -04:00
Thomas Harte
81a3899381 Adjusted the Z80 formally to communicate in terms of half cycles rather than whole. 2017-07-26 19:42:00 -04:00
Thomas Harte
9257a3f6d7 Added test for 16-bit arithmetic, and fixed implementation. 2017-07-26 19:04:52 -04:00
Thomas Harte
6ec4e4e3d7 Merge branch 'master' into Memptr 2017-07-25 23:01:34 -04:00
Thomas Harte
966b5e6372 Adapted the Z80's perform_machine_cycle to return Cycles. 2017-07-25 22:25:44 -04:00
Thomas Harte
75d67ee770 Relocated ClockReceiver.hpp as it's a dependency for parts of the static analyser, and therefore needs to be distinct from the actual emulation parts. 2017-07-25 20:20:55 -04:00
Thomas Harte
a1e9a54765 Eliminated redundant uses of ClockReceiver and sought to ensure that proper run_fors are inherited all the way down. 2017-07-25 20:09:13 -04:00
Thomas Harte
b82bef95f3 Decided to follow through on Cycles and HalfCycles as complete integer-alikes. Which means giving them the interesting range of operators. Also killed the implicit conversion to int as likely to lead to type confusion. 2017-07-24 20:10:05 -04:00
Thomas Harte
ec3aa06caf Removed dangling reference. 2017-07-23 22:16:00 -04:00
Thomas Harte
ba088e5545 Adapted the Z80 into a clock receiver, which also vends Cycles rather than a raw int within its PartialMachineCycle struct. The objective is to update it to vend HalfCycles within its struct, but I think I need to do some work on cycle/half-cycle arithmetic first. 2017-07-23 22:15:04 -04:00
Thomas Harte
20a6bcc676 Added tests for the various LD (nn), rr instructions and corrected implementation to pass. 2017-07-22 11:39:13 -04:00
Thomas Harte
eaf313b0f6 Added a test on LD A, (DE) and LD A, (BC), and adjusted implementation to pass. 2017-07-22 11:20:21 -04:00
Thomas Harte
d51b66c204 Expanded test to hit all 65536 possibilities (and not to allocate a fresh Z80 test machine each time, as that's unnecessary and slow), and fixed implementation to pass test. 2017-07-21 23:01:35 -04:00
Thomas Harte
540a03f75c Exposed the memptr register. 2017-07-21 22:31:42 -04:00
Thomas Harte
9b72c445a7 Fixed indexing type. 2017-07-21 21:19:46 -04:00
Thomas Harte
aec4fd066b I think I've definitively decided against this model of timing. 2017-06-22 21:32:14 -04:00
Thomas Harte
95a6b0f85c Introduced an NMI/wait interrupt timing test, and adjusted the Z80 to conform to information posted by Wilf Rigter. 2017-06-22 21:09:26 -04:00
Thomas Harte
b7c978e078 Added getters for most of the input lines, and attempted to round out the ZX81's wait logic. 2017-06-22 20:11:19 -04:00
Thomas Harte
f0398a6db8 Added wait state hooks to the interrupt programs, and added an is_wait query on PartialMachineCycle. 2017-06-22 20:07:47 -04:00
Thomas Harte
7eeac3b586 Switched R back to incrementing after the refresh cycle. It had snuck to before by virtue of subdivision of the M1 cycle. Which shortened the ZX80 line time, breaking synchronisation. 2017-06-21 21:11:00 -04:00
Thomas Harte
0e0ce379b4 Renamed MachineCycle to PartialMachineCycle given that it mostly no longer intends to describe an entire machine cycle. 2017-06-21 20:38:08 -04:00
Thomas Harte
36e8a11505 Sought to simplify the way partial machine cycles are communicated, for ease of machine implementation. Also implemented the wait line. 2017-06-21 20:32:08 -04:00
Thomas Harte
45f442ea63 Corrected interrupt mode 2: was both failing properly to load the vector address, and failing to read from it. 2017-06-21 19:08:48 -04:00
Thomas Harte
db743c90d8 Had neglected to count refresh time in my interrupt programs. Corrected. Mode 0 timing test succeeds again. Only Mode 2 is now at fault. 2017-06-21 18:58:44 -04:00
Thomas Harte
10cc94f581 Attempted to fix interrupt response timing; ensured initial interrupt mode is one that won't jump beyond the interrupt response program table's length, and that the conditionals other than CALL definitely have no alternative program attached. 2017-06-21 18:47:00 -04:00
Thomas Harte
108da64562 Fixed LD H, (HL) and LD L, (HL) by ensuring that whatever the subclass does goes to a temporary place before updating the address. Corrected the LD (IX+d), n machine cycle test for my new best-guess timing. This should leave only interrupt timing as currently amiss. 2017-06-20 22:25:00 -04:00
Thomas Harte
f85b46286e Resolved the timing disparity between LD (HL),n and LD (IX+d), n, hopefully having come up with a convincing theory of timing for the latter. 2017-06-20 22:20:58 -04:00
Thomas Harte
184b371649 Attempted to get to 'proper' timing for LD (IX+d),n, albeit that proper is a guess. 2017-06-20 21:48:50 -04:00
Thomas Harte
b0375bb037 Fixed the three LD rr, (nn) operations. Back down to four FUSE failures. 2017-06-20 21:32:23 -04:00
Thomas Harte
48942848e7 Fixed (Ix+d) read timing. I've put an extra wait cycle into the read, so no need to extend the refresh. 2017-06-20 21:15:56 -04:00
Thomas Harte
27ac342928 Corrected conditional call timing, and its test. 2017-06-20 20:57:23 -04:00
Thomas Harte
25aba16ef8 Quickly checking the FUSE tests, corrected a handful of instances where PC should be modified but isn't, correcting around 800 new failures. 2017-06-19 22:20:23 -04:00
Thomas Harte
a0d0f383c8 Corrected unconditional CALL timing. Conditional's going to require more work because once the wait state is put into the right place, it breaks the assumption under which the Z80 handles conditions — that they're either do something or else do nothing. So that can wait a day. 2017-06-19 22:07:36 -04:00
Thomas Harte
cc8f316941 Resolved read-modify-write (IX+d) timing, and therefore RLC (IX+d). 2017-06-19 20:51:28 -04:00