ca65 Users Guide <author><url url="mailto:uz@cc65.org" name="Ullrich von Bassewitz">,<newline> <url url="mailto:greg.king5@verizon.net" name="Greg King"> <abstract> ca65 is a powerful macro assembler for the 6502, 65C02, and 65816 CPUs. It is used as a companion assembler for the cc65 crosscompiler, but it may also be used as a standalone product. </abstract> <!-- Table of contents --> <toc> <!-- Begin the document --> <sect>Overview<p> ca65 is a replacement for the ra65 assembler that was part of the cc65 C compiler, originally developed by John R. Dunning. I had some problems with ra65 and the copyright does not permit some things which I wanted to be possible, so I decided to write a completely new assembler/linker/archiver suite for the cc65 compiler. ca65 is part of this suite. Some parts of the assembler (code generation and some routines for symbol table handling) are taken from an older crossassembler named a816 written by me a long time ago. <sect1>Design criteria<p> Here's a list of the design criteria, that I considered important for the development: <itemize> <item> The assembler must support macros. Macros are not essential, but they make some things easier, especially when you use the assembler in the backend of a compiler. <item> The assembler must support the newer 65C02 and 65816 CPUs. I have been thinking about a 65816 backend for the C compiler, and even my old a816 assembler had support for these CPUs, so this wasn't really a problem. <item> The assembler must produce relocatable code. This is necessary for the compiler support, and it is more convenient. <item> Conditional assembly must be supported. This is a must for bigger projects written in assembler (like Elite128). <item> The assembler must support segments, and it must support more than three segments (this is the count, most other assemblers support). Having more than one code segments helps developing code for systems with a divided ROM area (like the C64). <item> The linker must be able to resolve arbitrary expressions. It should be able to get things like <tscreen><verb> .import S1, S2 .export Special Special = 2*S1 + S2/7 </verb></tscreen> right. <item> True lexical nesting for symbols. This is very convenient for larger assembly projects. <item> "Cheap" local symbols without lexical nesting for those quick, late night hacks. <item> I liked the idea of "options" as Anre Fachats .o65 format has it, so I introduced the concept into the object file format use by the new cc65 binutils. <item> The assembler will be a one pass assembler. There was no real need for this decision, but I've written several multipass assemblers, and it started to get boring. A one pass assembler needs much more elaborated data structures, and because of that it's much more fun:-) <item> Non-GPLed code that may be used in any project without restrictions or fear of "GPL infecting" other code. </itemize> <p> <sect>Usage<p> <sect1>Command line option overview<p> The assembler accepts the following options: <tscreen><verb> --------------------------------------------------------------------------- Usage: ca65 [options] file Short options: -D name[=value] Define a symbol -I dir Set an include directory search path -U Mark unresolved symbols as import -V Print the assembler version -W n Set warning level n -d Debug mode -g Add debug info to object file -h Help (this text) -i Ignore case of symbols -l name Create a listing file if assembly was ok -mm model Set the memory model -o name Name the output file -s Enable smart mode -t sys Set the target system -v Increase verbosity Long options: --auto-import Mark unresolved symbols as import --bin-include-dir dir Set a search path for binary includes --cpu type Set cpu type --create-dep name Create a make dependency file --create-full-dep name Create a full make dependency file --debug Debug mode --debug-info Add debug info to object file --feature name Set an emulation feature --help Help (this text) --ignore-case Ignore case of symbols --include-dir dir Set an include directory search path --large-alignment Don't warn about large alignments --listing name Create a listing file if assembly was ok --list-bytes n Maximum number of bytes per listing line --memory-model model Set the memory model --pagelength n Set the page length for the listing --relax-checks Disables some error checks --smart Enable smart mode --target sys Set the target system --verbose Increase verbosity --version Print the assembler version --warnings-as-errors Treat warnings as errors --------------------------------------------------------------------------- </verb></tscreen> <sect1>Command line options in detail<p> Here is a description of all the command line options: <descrip> <label id="option--bin-include-dir"> <tag><tt>--bin-include-dir dir</tt></tag> Name a directory which is searched for binary include files. The option may be used more than once to specify more than one directory to search. The current directory is always searched first before considering any additional directories. See also the section about <ref id="search-paths" name="search paths">. <label id="option--cpu"> <tag><tt>--cpu type</tt></tag> Set the default for the CPU type. The option takes a parameter, which may be one of 6502, 6502X, 6502DTV, 65SC02, 65C02, 65816, sweet16, HuC6280, 4510 <label id="option-create-dep"> <tag><tt>--create-dep name</tt></tag> Tells the assembler to generate a file containing the dependency list for the assembled module in makefile syntax. The output is written to a file with the given name. The output does not include files passed via debug information to the assembler. <label id="option-create-full-dep"> <tag><tt>--create-full-dep name</tt></tag> Tells the assembler to generate a file containing the dependency list for the assembled module in makefile syntax. The output is written to a file with the given name. The output does include files passed via debug information to the assembler. <tag><tt>-d, --debug</tt></tag> Enables debug mode, something that should not be needed for mere mortals:-) <label id="option--feature"> <tag><tt>--feature name</tt></tag> Enable an emulation feature. This is identical as using <tt/.FEATURE/ in the source with two exceptions: Feature names must be lower case, and each feature must be specified by using a separate <tt/--feature/ option, comma separated lists are not allowed. See the discussion of the <tt><ref id=".FEATURE" name=".FEATURE"></tt> command for a list of emulation features. <label id="option-g"> <tag><tt>-g, --debug-info</tt></tag> When this option (or the equivalent control command <tt/.DEBUGINFO/) is used, the assembler will add a section to the object file that contains all symbols (including local ones) together with the symbol values and source file positions. The linker will put these additional symbols into the VICE label file, so even local symbols can be seen in the VICE monitor. <label id="option-h"> <tag><tt>-h, --help</tt></tag> Print the short option summary shown above. <label id="option-i"> <tag><tt>-i, --ignore-case</tt></tag> This option makes the assembler case insensitive on identifiers and labels. This option will override the default, but may itself be overridden by the <tt><ref id=".CASE" name=".CASE"></tt> control command. <label id="option-l"> <tag><tt>-l name, --listing name</tt></tag> Generate an assembler listing with the given name. A listing file will never be generated in case of assembly errors. <label id="option--large-alignment"> <tag><tt>--large-alignment</tt></tag> Disable warnings about a large combined alignment. See the discussion of the <tt><ref id=".ALIGN" name=".ALIGN"></tt> directive for further information. <label id="option--list-bytes"> <tag><tt>--list-bytes n</tt></tag> Set the maximum number of bytes printed in the listing for one line of input. See the <tt><ref id=".LISTBYTES" name=".LISTBYTES"></tt> directive for more information. The value zero can be used to encode an unlimited number of printed bytes. <label id="option-mm"> <tag><tt>-mm model, --memory-model model</tt></tag> Define the default memory model. Possible model specifiers are near, far and huge. <label id="option-o"> <tag><tt>-o name</tt></tag> The default output name is the name of the input file with the extension replaced by ".o". If you don't like that, you may give another name with the -o option. The output file will be placed in the same directory as the source file, or, if -o is given, the full path in this name is used. <label id="option--pagelength"> <tag><tt>--pagelength n</tt></tag> sets the length of a listing page in lines. See the <tt><ref id=".PAGELENGTH" name=".PAGELENGTH"></tt> directive for more information. <label id="option--relax-checks"> <tag><tt>--relax-checks</tt></tag> Disables some error checks done by the assembler. This will allow code that is an error in most cases and flagged as such by the assembler, but can be valid in special situations. Disabled checks are: <itemize> <item>Address vs. fragment size: a byte sized load from an non-zeropage address is truncated instead of producing an error. <item>Indirect jump on page boundary: <tt>jmp (label)</tt> on a label that resides on a page boundary (<tt>$xxFF</tt>) fetches the second byte from the wrong address on 6502 CPUs, now allowed instead of producing an error. </itemize> <label id="option-s"> <tag><tt>-s, --smart-mode</tt></tag> In smart mode (enabled by -s or the <tt><ref id=".SMART" name=".SMART"></tt> pseudo instruction) the assembler will track usage of the <tt/REP/ and <tt/SEP/ instructions in 65816 mode and update the operand sizes accordingly. If the operand of such an instruction cannot be evaluated by the assembler (for example, because the operand is an imported symbol), a warning is issued. Beware: Since the assembler cannot trace the execution flow this may lead to false results in some cases. If in doubt, use the .ixx and .axx instructions to tell the assembler about the current settings. Smart mode is off by default. <label id="option-t"> <tag><tt>-t sys, --target sys</tt></tag> Set the target system. This will enable translation of character strings and character constants into the character set of the target platform. The default for the target system is "none", which means that no translation will take place. The assembler supports the same target systems as the compiler, see there for a list. Depending on the target, the default CPU type is also set. This can be overridden by using the <tt/<ref id="option--cpu" name="--cpu">/ option. <label id="option-v"> <tag><tt>-v, --verbose</tt></tag> Increase the assembler verbosity. Usually only needed for debugging purposes. You may use this option more than one time for even more verbose output. <label id="option-D"> <tag><tt>-D</tt></tag> This option allows you to define symbols on the command line. Without a value, the symbol is defined with the value zero. When giving a value, you may use the '$' prefix for hexadecimal symbols. Please note that for some operating systems, '$' has a special meaning, so you may have to quote the expression. <label id="option-I"> <tag><tt>-I dir, --include-dir dir</tt></tag> Name a directory which is searched for include files. The option may be used more than once to specify more than one directory to search. The current directory is always searched first before considering any additional directories. See also the section about <ref id="search-paths" name="search paths">. <label id="option-U"> <tag><tt>-U, --auto-import</tt></tag> Mark symbols that are not defined in the sources as imported symbols. This should be used with care since it delays error messages about typos and such until the linker is run. The compiler uses the equivalent of this switch (<tt><ref id=".AUTOIMPORT" name=".AUTOIMPORT"></tt>) to enable auto imported symbols for the runtime library. However, the compiler is supposed to generate code that runs through the assembler without problems, something which is not always true for assembler programmers. <label id="option-V"> <tag><tt>-V, --version</tt></tag> Print the version number of the assembler. If you send any suggestions or bugfixes, please include the version number. <label id="option-W"> <tag><tt>-Wn</tt></tag> Set the warning level for the assembler. Using -W2 the assembler will even warn about such things like unused imported symbols. The default warning level is 1, and it would probably be silly to set it to something lower. <label id="option--warnings-as-errors"> <tag><tt>--warnings-as-errors</tt></tag> An error will be generated if any warnings were produced. </descrip> <p> <sect>Search paths<label id="search-paths"><p> Normal include files are searched in the following places: <enum> <item>The current file's directory. <item>Any directory added with the <tt/<ref id="option-I" name="-I">/ option on the command line. <item>The value of the environment variable <tt/CA65_INC/ if it is defined. <item>A subdirectory named <tt/asminc/ of the directory defined in the environment variable <tt/CC65_HOME/, if it is defined. <item>An optionally compiled-in directory. </enum> Binary include files are searched in the following places: <enum> <item>The current file's directory. <item>Any directory added with the <tt/<ref id="option--bin-include-dir" name="--bin-include-dir">/ option on the command line. </enum> <sect>Input format<p> <sect1>Assembler syntax<p> The assembler accepts the standard 6502/65816 assembler syntax. One line may contain a label (which is identified by a colon), and, in addition to the label, an assembler mnemonic, a macro, or a control command (see section <ref id="control-commands" name="Control Commands"> for supported control commands). Alternatively, the line may contain a symbol definition using the '=' token. Everything after a semicolon is handled as a comment (that is, it is ignored). Here are some examples for valid input lines: <tscreen><verb> Label: ; A label and a comment lda #$20 ; A 6502 instruction plus comment L1: ldx #$20 ; Same with label L2: .byte "Hello world" ; Label plus control command mymac $20 ; Macro expansion MySym = 3*L1 ; Symbol definition MaSym = Label ; Another symbol </verb></tscreen> The assembler accepts <itemize> <item>all valid 6502 mnemonics when in 6502 mode (the default or after the <tt><ref id=".P02" name=".P02"></tt> command was given). <item>all valid 6502 mnemonics plus a set of illegal instructions when in <ref id="6502X-mode" name="6502X mode">. <item>all valid 6502DTV mnemonics when in 6502DTV mode (after the <tt><ref id=".PDTV" name=".PDTV"></tt> command was given). <item>all valid 65SC02 mnemonics when in 65SC02 mode (after the <tt><ref id=".PSC02" name=".PSC02"></tt> command was given). <item>all valid 65C02 mnemonics when in 65C02 mode (after the <tt><ref id=".PC02" name=".PC02"></tt> command was given). <item>all valid 65816 mnemonics when in 65816 mode (after the <tt><ref id=".P816" name=".P816"></tt> command was given). <item>all valid 4510 mnemonics when in 4510 mode (after the <tt><ref id=".P4510" name=".P4510"></tt> command was given). </itemize> On 6502-derived platforms the <tt/BRK/ instruction has an optional signature byte. If omitted, the assembler will only produce only 1 byte. <tscreen><verb> brk ; 1-byte: $00 brk $34 ; 2-bytes: $00 $34 brk #$34 ; 2-bytes: $00 $34 </verb></tscreen> <sect1>65816 mode<p> In 65816 mode, several aliases are accepted, in addition to the official mnemonics: <itemize> <item><tt>CPA</tt> is an alias for <tt>CMP</tt> <item><tt>DEA</tt> is an alias for <tt>DEC A</tt> <item><tt>INA</tt> is an alias for <tt>INC A</tt> <item><tt>SWA</tt> is an alias for <tt>XBA</tt> <item><tt>TAD</tt> is an alias for <tt>TCD</tt> <item><tt>TAS</tt> is an alias for <tt>TCS</tt> <item><tt>TDA</tt> is an alias for <tt>TDC</tt> <item><tt>TSA</tt> is an alias for <tt>TSC</tt> </itemize> The <tt/MVN/ and <tt/MVP/ instructions accept two different argument forms. Either two bank bytes may be given with a <tt/#/ prefix, or two far addresses whose high byte will be used. <tscreen><verb> mvn #^src, #^dst ; bank of src to bank of dst mvn src, dst ; bank of src to bank of dst mvp #$12, #$78 ; bank $12 to $78 mvp $123456, $789ABC ; bank $12 to $78 </verb></tscreen> <sect1>6502X mode<label id="6502X-mode"><p> 6502X mode is an extension to the normal 6502 mode. In this mode, several mnemonics for illegal instructions of the NMOS 6502 CPUs are accepted. Since these instructions are illegal, there are no official mnemonics for them. The unofficial ones are taken from <url url="http://www.oxyron.de/html/opcodes02.html">. Please note that only the ones marked as "stable" are supported. The following table uses information from the mentioned web page, for more information, see there. <itemize> <item><tt>ALR: A:=(A and #{imm})/2;</tt> <item><tt>ANC: A:=A and #{imm};</tt> Generates opcode $0B. <item><tt>ARR: A:=(A and #{imm})/2;</tt> <item><tt>AXS: X:=A and X-#{imm};</tt> <item><tt>DCP: {adr}:={adr}-1; A-{adr};</tt> <item><tt>ISC: {adr}:={adr}+1; A:=A-{adr};</tt> <item><tt>LAS: A,X,S:={adr} and S;</tt> <item><tt>LAX: A,X:={adr};</tt> <item><tt>RLA: {adr}:={adr}rol; A:=A and {adr};</tt> <item><tt>RRA: {adr}:={adr}ror; A:=A adc {adr};</tt> <item><tt>SAX: {adr}:=A and X;</tt> <item><tt>SLO: {adr}:={adr}*2; A:=A or {adr};</tt> <item><tt>SRE: {adr}:={adr}/2; A:=A xor {adr};</tt> </itemize> <sect1>4510 mode<p> The 4510 is a microcontroller that is the core of the Commodore C65 aka C64DX. It contains among other functions a slightly modified 65CE02/4502 CPU, to allow address mapping for 20 bits of address space (1 megabyte addressable area). As compared to the description of the CPU in the <url url="http://www.zimmers.net/anonftp/pub/cbm/c65/c65manualupdated.txt.gz" name="C65 System Specification"> <url url="https://raw.githubusercontent.com/MEGA65/c65-specifications/master/c65manualupdated.txt" name="(updated version)"> uses these changes: <itemize> <item><tt>LDA (d,SP),Y</tt> may also be written as <tt>LDA (d,S),Y</tt> (matching the 65816 notataion). <item>All branch instruction allow now 16 bit offsets. To use a 16 bit branch you have to prefix these with an "L" (e.g. "<tt>LBNE</tt>" instead of "<tt>BNE</tt>"). This might change at a later implementation of the assembler. </itemize> For more information about the Commodore C65/C64DX and the 4510 CPU, see <url url="http://www.zimmers.net/anonftp/pub/cbm/c65/"> and <url url="https://en.wikipedia.org/wiki/Commodore_65" name="Wikipedia">. <sect1>sweet16 mode<label id="sweet16-mode"><p> SWEET 16 is an interpreter for a pseudo 16 bit CPU written by Steve Wozniak for the Apple ][ machines. It is available in the Apple ][ ROM. ca65 can generate code for this pseudo CPU when switched into sweet16 mode. The following is special in sweet16 mode: <itemize> <item>The '@' character denotes indirect addressing and is no longer available for cheap local labels. If you need cheap local labels, you will have to switch to another lead character using the <tt/<ref id=".LOCALCHAR" name=".LOCALCHAR">/ command. <item>Registers are specified using <tt/R0/ .. <tt/R15/. In sweet16 mode, these identifiers are reserved words. </itemize> Please note that the assembler does neither supply the interpreter needed for SWEET 16 code, nor the zero page locations needed for the SWEET 16 registers, nor does it call the interpreter. All this must be done by your program. Apple ][ programmers do probably know how to use sweet16 mode. For more information about SWEET 16, see <url url="http://www.6502.org/source/interpreters/sweet16.htm">. <sect1>Number format<p> For literal values, the assembler accepts the widely used number formats: A preceding '$' or a trailing 'h' denotes a hex value, a preceding '%' denotes a binary value, and a bare number is interpreted as a decimal. There are currently no octal values and no floats. <sect1>Conditional assembly<p> Please note that when using the conditional directives (<tt/.IF/ and friends), the input must consist of valid assembler tokens, even in <tt/.IF/ branches that are not assembled. The reason for this behaviour is that the assembler must still be able to detect the ending tokens (like <tt/.ENDIF/), so conversion of the input stream into tokens still takes place. As a consequence conditional assembly directives may <bf/not/ be used to prevent normal text (used as a comment or similar) from being assembled. <p> <sect>Expressions<p> <sect1>Expression evaluation<p> All expressions are evaluated with (at least) 32 bit precision. An expression may contain constant values and any combination of internal and external symbols. Expressions that cannot be evaluated at assembly time are stored inside the object file for evaluation by the linker. Expressions referencing imported symbols must always be evaluated by the linker. <sect1>Size of an expression result<p> Sometimes, the assembler must know about the size of the value that is the result of an expression. This is usually the case, if a decision has to be made, to generate a zero page or an absolute memory references. In this case, the assembler has to make some assumptions about the result of an expression: <itemize> <item> If the result of an expression is constant, the actual value is checked to see if it's a byte sized expression or not. <item> If the expression is explicitly casted to a byte sized expression by one of the '>', '<' or '^' operators, it is a byte expression. <item> If this is not the case, and the expression contains a symbol, explicitly declared as zero page symbol (by one of the .importzp or .exportzp instructions), then the whole expression is assumed to be byte sized. <item> If the expression contains symbols that are not defined, and these symbols are local symbols, the enclosing scopes are searched for a symbol with the same name. If one exists and this symbol is defined, its attributes are used to determine the result size. <item> In all other cases the expression is assumed to be word sized. </itemize> Note: If the assembler is not able to evaluate the expression at assembly time, the linker will evaluate it and check for range errors as soon as the result is known. <sect1>Boolean expressions<p> In the context of a boolean expression, any non zero value is evaluated as true, any other value to false. The result of a boolean expression is 1 if it's true, and zero if it's false. There are boolean operators with extreme low precedence with version 2.x (where x > 0). The <tt/.AND/ and <tt/.OR/ operators are shortcut operators. That is, if the result of the expression is already known, after evaluating the left hand side, the right hand side is not evaluated. <sect1>Constant expressions<p> Sometimes an expression must evaluate to a constant without looking at any further input. One such example is the <tt/<ref id=".IF" name=".IF">/ command that decides if parts of the code are assembled or not. An expression used in the <tt/.IF/ command cannot reference a symbol defined later, because the decision about the <tt/.IF/ must be made at the point when it is read. If the expression used in such a context contains only constant numerical values, there is no problem. When unresolvable symbols are involved it may get harder for the assembler to determine if the expression is actually constant, and it is even possible to create expressions that aren't recognized as constant. Simplifying the expressions will often help. In cases where the result of the expression is not needed immediately, the assembler will delay evaluation until all input is read, at which point all symbols are known. So using arbitrary complex constant expressions is no problem in most cases. <sect1>Available operators<label id="operators"><p> <table> <tabular ca="clc"> <bf/Operator/| <bf/Description/| <bf/Precedence/@<hline> | Built-in string functions| 0@ ~|~|~@ | Built-in pseudo-variables| 1@ | Built-in pseudo-functions| 1@ +| Unary positive| 1@ -| Unary negative| 1@ ˜<newline> .BITNOT| Unary bitwise not| 1@ <<newline> .LOBYTE| Unary low-byte operator| 1@ ><newline> .HIBYTE| Unary high-byte operator| 1@ ^<newline> .BANKBYTE| Unary bank-byte operator| 1@ ~|~|~@ *| Multiplication| 2@ /| Division| 2@ .MOD| Modulo operator| 2@ &<newline> .BITAND| Bitwise and| 2@ ^<newline> .BITXOR| Binary bitwise xor| 2@ <<<newline> .SHL| Shift-left operator| 2@ >><newline> .SHR| Shift-right operator| 2@ ~|~|~@ +| Binary addition| 3@ -| Binary subtraction| 3@ |<newline> .BITOR| Bitwise or| 3@ ~|~|~@ = | Compare operator (equal)| 4@ <>| Compare operator (not equal)| 4@ <| Compare operator (less)| 4@ >| Compare operator (greater)| 4@ <=| Compare operator (less or equal)| 4@ >=| Compare operator (greater or equal)| 4@ ~|~|~@ &&<newline> .AND| Boolean and| 5@ .XOR| Boolean xor| 5@ ~|~|~@ ||<newline> .OR| Boolean or| 6@ ~|~|~@ !<newline> .NOT| Boolean not| 7 </tabular> <caption>Available operators, sorted by precedence </table> To force a specific order of evaluation, parentheses may be used, as usual. <sect>Symbols and labels<p> A symbol or label is an identifier that starts with a letter and is followed by letters and digits. Depending on some features enabled (see <tt><ref id="at_in_identifiers" name="at_in_identifiers"></tt>, <tt><ref id="dollar_in_identifiers" name="dollar_in_identifiers"></tt> and <tt><ref id="leading_dot_in_identifiers" name="leading_dot_in_identifiers"></tt>) other characters may be present. Use of identifiers consisting of a single character will not work in all cases, because some of these identifiers are reserved keywords (for example "A" is not a valid identifier for a label, because it is the keyword for the accumulator). The assembler allows you to use symbols instead of naked values to make the source more readable. There are a lot of different ways to define and use symbols and labels, giving a lot of flexibility. <sect1>Numeric constants<p> Numeric constants are defined using the equal sign or the label assignment operator. After doing <tscreen><verb> two = 2 </verb></tscreen> may use the symbol "two" in every place where a number is expected, and it is evaluated to the value 2 in this context. The label assignment operator is almost identical, but causes the symbol to be marked as a label, so it may be handled differently in a debugger: <tscreen><verb> io := $d000 </verb></tscreen> The right side can of course be an expression: <tscreen><verb> four = two * two </verb></tscreen> <label id="variables"> <sect1>Numeric variables<p> Within macros and other control structures (<tt><ref id=".REPEAT" name=".REPEAT"></tt>, ...) it is sometimes useful to have some sort of variable. This can be achieved by the <tt>.SET</tt> operator. It creates a symbol that may get assigned a different value later: <tscreen><verb> four .set 4 lda #four ; Loads 4 into A four .set 3 lda #four ; Loads 3 into A </verb></tscreen> Since the value of the symbol can change later, it must be possible to evaluate it when used (no delayed evaluation as with normal symbols). So the expression used as the value must be constant. Following is an example for a macro that generates a different label each time it is used. It uses the <tt><ref id=".SPRINTF" name=".SPRINTF"></tt> function and a numeric variable named <tt>lcount</tt>. <tscreen><verb> .lcount .set 0 ; Initialize the counter .macro genlab .ident (.sprintf ("L%04X", lcount)): lcount .set lcount + 1 .endmacro </verb></tscreen> <sect1>Standard labels<p> A label is defined by writing the name of the label at the start of the line (before any instruction mnemonic, macro or pseudo directive), followed by a colon. This will declare a symbol with the given name and the value of the current program counter. <sect1>Local labels and symbols<p> Using the <tt><ref id=".PROC" name=".PROC"></tt> directive, it is possible to create regions of code where the names of labels and symbols are local to this region. They are not known outside of this region and cannot be accessed from there. Such regions may be nested like PROCEDUREs in Pascal. See the description of the <tt><ref id=".PROC" name=".PROC"></tt> directive for more information. <sect1>Cheap local labels<p> Cheap local labels are defined like standard labels, but the name of the label must begin with a special symbol (usually '@', but this can be changed by the <tt><ref id=".LOCALCHAR" name=".LOCALCHAR"></tt> directive). Cheap local labels are visible only between two non cheap labels. As soon as a standard symbol is encountered (this may also be a local symbol if inside a region defined with the <tt><ref id=".PROC" name=".PROC"></tt> directive), the cheap local symbol goes out of scope. You may use cheap local labels as an easy way to reuse common label names like "Loop". Here is an example: <tscreen><verb> Clear: lda #$00 ; Global label ldy #$20 @Loop: sta Mem,y ; Local label dey bne @Loop ; Ok rts Sub: ... ; New global label bne @Loop ; ERROR: Unknown identifier! </verb></tscreen> <sect1>Unnamed labels<p> If you really want to write messy code, there are also unnamed labels. These labels do not have a name (you guessed that already, didn't you?). A colon is used to mark the absence of the name. Unnamed labels may be accessed by using the colon plus several minus or plus characters as a label designator. Using the '-' characters will create a back reference (use the n'th label backwards), using '+' will create a forward reference (use the n'th label in forward direction). An example will help to understand this: <tscreen><verb> : lda (ptr1),y ; #1 cmp (ptr2),y bne :+ ; -> #2 tax beq :+++ ; -> #4 iny bne :- ; -> #1 inc ptr1+1 inc ptr2+1 bne :- ; -> #1 : bcs :+ ; #2 -> #3 ldx #$FF rts : ldx #$01 ; #3 : rts ; #4 </verb></tscreen> As you can see from the example, unnamed labels will make even short sections of code hard to understand, because you have to count labels to find branch targets (this is the reason why I for my part do prefer the "cheap" local labels). Nevertheless, unnamed labels are convenient in some situations, so it's your decision. <em/Note:/ <ref id="scopes" name="Scopes"> organize named symbols, not unnamed ones, so scopes don't have an effect on unnamed labels. <sect1>Using macros to define labels and constants<p> While there are drawbacks with this approach, it may be handy in a few rare situations. Using <tt><ref id=".DEFINE" name=".DEFINE"></tt>, it is possible to define symbols or constants that may be used elsewhere. One of the advantages is that you can use it to define string constants (this is not possible with the other symbol types). Please note: <tt/.DEFINE/ style macros do token replacements on a low level, so the names do not adhere to scoping, diagnostics may be misleading, there are no symbols to look up in the map file, and there is no debug info. Especially the first problem in the list can lead to very nasty programming errors. Because of these problems, the general advice is, <bf/NOT/ do use <tt/.DEFINE/ if you don't have to. Example: <tscreen><verb> .DEFINE two 2 .DEFINE version "SOS V2.3" four = two * two ; Ok .byte version ; Ok .PROC ; Start local scope two = 3 ; Will give "2 = 3" - invalid! .ENDPROC </verb></tscreen> <sect1>Symbols and <tt>.DEBUGINFO</tt><p> If <tt><ref id=".DEBUGINFO" name=".DEBUGINFO"></tt> is enabled (or <ref id="option-g" name="-g"> is given on the command line), global, local and cheap local labels are written to the object file and will be available in the symbol file via the linker. Unnamed labels are not written to the object file, because they don't have a name which would allow to access them. <sect>Scopes<label id="scopes"><p> ca65 implements several sorts of scopes for symbols. <sect1>Global scope<p> All (non cheap local) symbols that are declared outside of any nested scopes are in global scope. <sect1>Cheap locals<p> A special scope is the scope for cheap local symbols. It lasts from one non local symbol to the next one, without any provisions made by the programmer. All other scopes differ in usage but use the same concept internally. <sect1>Generic nested scopes<p> A nested scoped for generic use is started with <tt/<ref id=".SCOPE" name=".SCOPE">/ and closed with <tt/<ref id=".ENDSCOPE" name=".ENDSCOPE">/. The scope can have a name, in which case it is accessible from the outside by using <ref id="scopesyntax" name="explicit scopes">. If the scope does not have a name, all symbols created within the scope are local to the scope, and aren't accessible from the outside. A nested scope can access symbols from the local or from enclosing scopes by name without using explicit scope names. In some cases there may be ambiguities, for example if there is a reference to a local symbol that is not yet defined, but a symbol with the same name exists in outer scopes: <tscreen><verb> .scope outer foo = 2 .scope inner lda #foo foo = 3 .endscope .endscope </verb></tscreen> In the example above, the <tt/lda/ instruction will load the value 3 into the accumulator, because <tt/foo/ is redefined in the scope. However: <tscreen><verb> .scope outer foo = $1234 .scope inner lda foo,x foo = $12 .endscope .endscope </verb></tscreen> Here, <tt/lda/ will still load from <tt/$12,x/, but since it is unknown to the assembler that <tt/foo/ is a zeropage symbol when translating the instruction, absolute mode is used instead. In fact, the assembler will not use absolute mode by default, but it will search through the enclosing scopes for a symbol with the given name. If one is found, the address size of this symbol is used. This may lead to errors: <tscreen><verb> .scope outer foo = $12 .scope inner lda foo,x foo = $1234 .endscope .endscope </verb></tscreen> In this case, when the assembler sees the symbol <tt/foo/ in the <tt/lda/ instruction, it will search for an already defined symbol <tt/foo/. It will find <tt/foo/ in scope <tt/outer/, and a close look reveals that it is a zeropage symbol. So the assembler will use zeropage addressing mode. If <tt/foo/ is redefined later in scope <tt/inner/, the assembler tries to change the address in the <tt/lda/ instruction already translated, but since the new value needs absolute addressing mode, this fails, and an error message "Range error" is output. Of course the most simple solution for the problem is to move the definition of <tt/foo/ in scope <tt/inner/ upwards, so it precedes its use. There may be rare cases when this cannot be done. In these cases, you can use one of the address size override operators: <tscreen><verb> .scope outer foo = $12 .scope inner lda a:foo,x foo = $1234 .endscope .endscope </verb></tscreen> This will cause the <tt/lda/ instruction to be translated using absolute addressing mode, which means changing the symbol reference later does not cause any errors. <sect1>Nested procedures<p> A nested procedure is created by use of <tt/<ref id=".PROC" name=".PROC">/. It differs from a <tt/<ref id=".SCOPE" name=".SCOPE">/ in that it must have a name, and a it will introduce a symbol with this name in the enclosing scope. So <tscreen><verb> .proc foo ... .endproc </verb></tscreen> is actually the same as <tscreen><verb> foo: .scope foo ... .endscope </verb></tscreen> This is the reason why a procedure must have a name. If you want a scope without a name, use <tt/<ref id=".SCOPE" name=".SCOPE">/. <em/Note:/ As you can see from the example above, scopes and symbols live in different namespaces. There can be a symbol named <tt/foo/ and a scope named <tt/foo/ without any conflicts (but see the section titled <ref id="scopesearch" name=""Scope search order"">). <sect1>Structs, unions and enums<p> Structs, unions and enums are explained in a <ref id="structs" name="separate section">, I do only cover them here, because if they are declared with a name, they open a nested scope, similar to <tt/<ref id=".SCOPE" name=".SCOPE">/. However, when no name is specified, the behaviour is different: In this case, no new scope will be opened, symbols declared within a struct, union, or enum declaration will then be added to the enclosing scope instead. <sect1>Explicit scope specification<label id="scopesyntax"><p> Accessing symbols from other scopes is possible by using an explicit scope specification, provided that the scope where the symbol lives in has a name. The namespace token (<tt/::/) is used to access other scopes: <tscreen><verb> .scope foo bar: .word 0 .endscope ... lda foo::bar ; Access foo in scope bar </verb></tscreen> The only way to deny access to a scope from the outside is to declare a scope without a name (using the <tt/<ref id=".SCOPE" name=".SCOPE">/ command). A special syntax is used to specify the global scope: If a symbol or scope is preceded by the namespace token, the global scope is searched: <tscreen><verb> bar = 3 .scope foo bar = 2 lda #::bar ; Access the global bar (which is 3) .endscope </verb></tscreen> <sect1>Scope search order<label id="scopesearch"><p> The assembler searches for a scope in a similar way as for a symbol. First, it looks in the current scope, and then it walks up the enclosing scopes until the scope is found. However, one important thing to note when using explicit scope syntax is, that a symbol may be accessed before it is defined, but a scope may <bf/not/ be used without a preceding definition. This means that in the following example: <tscreen><verb> .scope foo bar = 3 .endscope .scope outer lda #foo::bar ; Will load 3, not 2! .scope foo bar = 2 .endscope .endscope </verb></tscreen> the reference to the scope <tt/foo/ will use the global scope, and not the local one, because the local one is not visible at the point where it is referenced. Things get more complex if a complete chain of scopes is specified: <tscreen><verb> .scope foo .scope outer .scope inner bar = 1 .endscope .endscope .scope another .scope nested lda #outer::inner::bar ; 1 .endscope .endscope .endscope .scope outer .scope inner bar = 2 .endscope .endscope </verb></tscreen> When <tt/outer::inner::bar/ is referenced in the <tt/lda/ instruction, the assembler will first search in the local scope for a scope named <tt/outer/. Since none is found, the enclosing scope (<tt/another/) is checked. There is still no scope named <tt/outer/, so scope <tt/foo/ is checked, and finally scope <tt/outer/ is found. Within this scope, <tt/inner/ is searched, and in this scope, the assembler looks for a symbol named <tt/bar/. Please note that once the anchor scope is found, all following scopes (<tt/inner/ in this case) are expected to be found exactly in this scope. The assembler will search the scope tree only for the first scope (if it is not anchored in the root scope). Starting from there on, there is no flexibility, so if the scope named <tt/outer/ found by the assembler does not contain a scope named <tt/inner/, this would be an error, even if such a pair does exist (one level up in global scope). Ambiguities that may be introduced by this search algorithm may be removed by anchoring the scope specification in the global scope. In the example above, if you want to access the "other" symbol <tt/bar/, you would have to write: <tscreen><verb> .scope foo .scope outer .scope inner bar = 1 .endscope .endscope .scope another .scope nested lda #::outer::inner::bar ; 2 .endscope .endscope .endscope .scope outer .scope inner bar = 2 .endscope .endscope </verb></tscreen> <sect>Address sizes and memory models<label id="address-sizes"><p> <sect1>Address sizes<p> ca65 assigns each segment and each symbol an address size. This is true, even if the symbol is not used as an address. You may also think of a value range of the symbol instead of an address size. Possible address sizes are: <itemize> <item>Zeropage or direct (8 bits) <item>Absolute (16 bits) <item>Far (24 bits) <item>Long (32 bits) </itemize> Since the assembler uses default address sizes for the segments and symbols, it is usually not necessary to override the default behaviour. In cases, where it is necessary, the following keywords may be used to specify address sizes: <itemize> <item>DIRECT, ZEROPAGE or ZP for zeropage addressing (8 bits). <item>ABSOLUTE, ABS or NEAR for absolute addressing (16 bits). <item>FAR for far addressing (24 bits). <item>LONG or DWORD for long addressing (32 bits). </itemize> <sect1>Address sizes of segments<p> The assembler assigns an address size to each segment. Since the representation of a label within this segment is "segment start + offset", labels will inherit the address size of the segment they are declared in. The address size of a segment may be changed, by using an optional address size modifier. See the <tt/<ref id=".SEGMENT" name="segment directive">/ for an explanation on how this is done. <sect1>Address sizes of symbols<p> The address size of a symbol can be specified with a prefix: <itemize> <item>z: zeropage addressing (8 bits). <item>a: absolute addressing (16 bits). <item>f: far addressing (24 bits). </itemize> The zeropage addressing override can be used to ensure the use of optimal zeropage instructions, or correct cases where the size isn't yet known due to the single-pass assembly model. The larger addressing overrides can be used to promote a smaller address to absolute or far addressing, instead of being automatically fit into a smaller addressing type. <sect1>Memory models<p> The default address size of a segment depends on the memory model used. Since labels inherit the address size from the segment they are declared in, changing the memory model is an easy way to change the address size of many symbols at once. <sect>Pseudo variables<label id="pseudo-variables"><p> Pseudo variables are readable in all cases, and in some special cases also writable. <sect1><tt>*</tt><p> Reading this pseudo variable will return the program counter at the start of the current input line. Assignment to this variable is possible when <tt/<ref id=".FEATURE" name=".FEATURE pc_assignment">/ is used. Note: You should not use assignments to <tt/*/, use <tt/<ref id=".ORG" name=".ORG">/ instead. <sect1><tt>.ASIZE</tt><label id=".ASIZE"><p> Reading this pseudo variable will return the current size of the Accumulator in bits. For the 65816 instruction set .ASIZE will return either 8 or 16, depending on the current size of the operand in immediate accu addressing mode. For all other CPU instruction sets, .ASIZE will always return 8. Example: <tscreen><verb> ; Reverse Subtract with Accumulator ; A = memory - A .macro rsb param .if .asize = 8 eor #$ff .else eor #$ffff .endif sec adc param .endmacro </verb></tscreen> See also: <tt><ref id=".ISIZE" name=".ISIZE"></tt> <sect1><tt>.CPU</tt><label id=".CPU"><p> Reading this pseudo variable will give a constant integer value that tells which CPU is currently enabled. It can also tell which instruction set the CPU is able to translate. The value read from the pseudo variable should be further examined by using one of the constants defined by the "cpu" macro package (see <tt/<ref id=".MACPACK" name=".MACPACK">/). It may be used to replace the .IFPxx pseudo instructions or to construct even more complex expressions. Example: <tscreen><verb> .macpack cpu .if (.cpu .bitand CPU_ISET_65816) phx phy .else txa pha tya pha .endif </verb></tscreen> <sect1><tt>.ISIZE</tt><label id=".ISIZE"><p> Reading this pseudo variable will return the current size of the Index register in bits. For the 65816 instruction set .ISIZE will return either 8 or 16, depending on the current size of the operand in immediate index addressing mode. For all other CPU instruction sets, .ISIZE will always return 8. See also: <tt><ref id=".ASIZE" name=".ASIZE"></tt> <sect1><tt>.PARAMCOUNT</tt><label id=".PARAMCOUNT"><p> This builtin pseudo variable is only available in macros. It is replaced by the actual number of parameters that were given in the macro invocation. Example: <tscreen><verb> .macro foo arg1, arg2, arg3 .if .paramcount <> 3 .error "Too few parameters for macro foo" .endif ... .endmacro </verb></tscreen> See section <ref id="macros" name="Macros">. <sect1><tt>.TIME</tt><label id=".TIME"><p> Reading this pseudo variable will give a constant integer value that represents the current time in POSIX standard (as seconds since the Epoch). It may be used to encode the time of translation somewhere in the created code. Example: <tscreen><verb> .dword .time ; Place time here </verb></tscreen> <sect1><tt>.VERSION</tt><label id=".VERSION"><p> Reading this pseudo variable will give the assembler version according to the following formula: <tt>(VER_MAJOR * 0x100) + VER_MINOR</tt> The upper 8 bits are the major-, the lower 8 bits are the minor version. Example: For example, version 47.11 of the assembler would have this macro defined as <tt/0x2f0b/. Note: until 2.19 this pseudo variable was defined as <tt>(VER_MAJOR * 0x100) + VER_MINOR * 0x10</tt> - which resulted in broken values starting at version 2.16 of the assembler. For this reason the value of this pseudo variable is considered purely informal - you should not use it to check for a specific assembler version and use different code according to the detected version - please update your code to work with the recent version of the assembler instead (There is very little reason to not use the most recent version - and even less to support older versions in your code). <sect>Pseudo functions<label id="pseudo-functions"><p> Pseudo functions expect their arguments in parentheses, and they have a result, either a string or an expression value. <sect1><tt>.ADDRSIZE</tt><label id=".ADDRSIZE"><p> The <tt/.ADDRSIZE/ function is used to return the internal address size associated with a symbol. This can be helpful in macros when knowing the address size of a symbol can help with custom instructions. Example: <tscreen><verb> .macro myLDA foo .if .ADDRSIZE(foo) = 1 ;do custom command based on zeropage addressing: .byte 0A5h, foo .elseif .ADDRSIZE(foo) = 2 ;do custom command based on absolute addressing: .byte 0ADh .word foo .elseif .ADDRSIZE(foo) = 0 ; no address size defined for this symbol: .out .sprintf("Error, address size unknown for symbol %s", .string(foo)) .endif .endmacro </verb></tscreen> <sect1><tt>.BANK</tt><label id=".BANK"><p> The <tt/.BANK/ function is used to support systems with banked memory. The argument is an expression with exactly one segment reference -- usually a label. The function result is the value of the <tt/bank/ attribute assigned to the run memory area of the segment. Please see the linker documentation for more information about memory areas and their attributes. The value of <tt/.BANK/ can be used to switch memory so that a memory bank containing specific data is available. The <tt/bank/ attribute is a 32-bit integer, and so is the result of the <tt/.BANK/ function. You will have to use <tt><ref id=".LOBYTE" name=".LOBYTE"></tt> or similar functions to address just part of it. Please note that <tt/.BANK/ always will get evaluated in the link stage, so an expression containing <tt/.BANK/ never can be used where a constant, known result is expected (for example, with <tt/.RES/). Example: <tscreen><verb> .segment "BANK1" .proc banked_func_1 ... .endproc .segment "BANK2" .proc banked_func_2 ... .endproc .proc bank_table .addr banked_func_1 .byte <.BANK (banked_func_1) .addr banked_func_2 .byte <.BANK (banked_func_2) .endproc </verb></tscreen> <sect1><tt>.BANKBYTE</tt><label id=".BANKBYTE"><p> The function returns the bank byte (that is, bits 16-23) of its argument. It works identical to the '^' operator. See: <tt><ref id=".HIBYTE" name=".HIBYTE"></tt>, <tt><ref id=".LOBYTE" name=".LOBYTE"></tt> <sect1><tt>.BLANK</tt><label id=".BLANK"><p> Builtin function. The function evaluates its argument in parentheses and yields "false" if the argument is non blank (there is an argument), and "true" if there is no argument. The token list that makes up the function argument may optionally be enclosed in curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right parenthesis). The curly braces are not considered part of the list, a list just consisting of curly braces is considered to be empty. As an example, the <tt/.IFBLANK/ statement may be replaced by <tscreen><verb> .if .blank({arg}) </verb></tscreen> <sect1><tt>.CONCAT</tt><label id=".CONCAT"><p> Builtin string function. The function allows to concatenate a list of string constants separated by commas. The result is a string constant that is the concatenation of all arguments. This function is most useful in macros and when used together with the <tt/.STRING/ builtin function. The function may be used in any case where a string constant is expected. Example: <tscreen><verb> .include .concat ("myheader", ".", "inc") </verb></tscreen> This is the same as the command <tscreen><verb> .include "myheader.inc" </verb></tscreen> <sect1><tt>.CONST</tt><label id=".CONST"><p> Builtin function. The function evaluates its argument in parentheses and yields "true" if the argument is a constant expression (that is, an expression that yields a constant value at assembly time) and "false" otherwise. As an example, the .IFCONST statement may be replaced by <tscreen><verb> .if .const(a + 3) </verb></tscreen> <sect1><tt>.DEF, .DEFINED</tt><label id=".DEFINED"><p> Builtin function. The function expects an identifier as argument in parentheses. The argument is evaluated, and the function yields "true" if the identifier is a symbol that already is defined somewhere in the source file up to the current position. Otherwise, the function yields false. As an example, the <tt><ref id=".IFDEF" name=".IFDEF"></tt> statement may be replaced by <tscreen><verb> .if .defined(a) </verb></tscreen> <sect1><tt>.DEFINEDMACRO</tt><label id=".DEFINEDMACRO"><p> Builtin function. The function expects an identifier as argument in parentheses. The argument is evaluated, and the function yields "true" if the identifier already has been defined as the name of a macro. Otherwise, the function yields false. Example: <tscreen><verb> .macro add foo clc adc foo .endmacro .if .definedmacro(add) add #$01 .else clc adc #$01 .endif </verb></tscreen> <sect1><tt>.HIBYTE</tt><label id=".HIBYTE"><p> The function returns the high byte (that is, bits 8-15) of its argument. It works identical to the '>' operator. See: <tt><ref id=".LOBYTE" name=".LOBYTE"></tt>, <tt><ref id=".BANKBYTE" name=".BANKBYTE"></tt> <sect1><tt>.HIWORD</tt><label id=".HIWORD"><p> The function returns the high word (that is, bits 16-31) of its argument. See: <tt><ref id=".LOWORD" name=".LOWORD"></tt> <sect1><tt>.IDENT</tt><label id=".IDENT"><p> The function expects a string as its argument, and converts this argument into an identifier. If the string starts with the current <tt/<ref id=".LOCALCHAR" name=".LOCALCHAR">/, it will be converted into a cheap local identifier, otherwise it will be converted into a normal identifier. Example: <tscreen><verb> .macro makelabel arg1, arg2 .ident (.concat (arg1, arg2)): .endmacro makelabel "foo", "bar" .word foobar ; Valid label </verb></tscreen> <sect1><tt>.ISMNEM, .ISMNEMONIC</tt><label id=".ISMNEMONIC"><p> Builtin function. The function expects an identifier as argument in parentheses. The argument is evaluated, and the function yields "true" if the identifier is defined as an instruction mnemonic that is recognized by the assembler. Example: <tscreen><verb> .if .not .ismnemonic(ina) .macro ina clc adc #$01 .endmacro .endif </verb></tscreen> <sect1><tt>.LEFT</tt><label id=".LEFT"><p> Builtin function. Extracts the left part of a given token list. Syntax: <tscreen><verb> .LEFT (<int expr>, <token list>) </verb></tscreen> The first integer expression gives the number of tokens to extract from the token list. The second argument is the token list itself. The token list may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). Example: To check in a macro if the given argument has a '#' as first token (immediate addressing mode), use something like this: <tscreen><verb> .macro ldax arg ... .if (.match (.left (1, {arg}), #)) ; ldax called with immediate operand ... .endif ... .endmacro </verb></tscreen> See also the <tt><ref id=".MID" name=".MID"></tt> and <tt><ref id=".RIGHT" name=".RIGHT"></tt> builtin functions. <sect1><tt>.LOBYTE</tt><label id=".LOBYTE"><p> The function returns the low byte (that is, bits 0-7) of its argument. It works identical to the '<' operator. See: <tt><ref id=".HIBYTE" name=".HIBYTE"></tt>, <tt><ref id=".BANKBYTE" name=".BANKBYTE"></tt> <sect1><tt>.LOWORD</tt><label id=".LOWORD"><p> The function returns the low word (that is, bits 0-15) of its argument. See: <tt><ref id=".HIWORD" name=".HIWORD"></tt> <sect1><tt>.MATCH</tt><label id=".MATCH"><p> Builtin function. Matches two token lists against each other. This is most useful within macros, since macros are not stored as strings, but as lists of tokens. The syntax is <tscreen><verb> .MATCH(<token list #1>, <token list #2>) </verb></tscreen> Both token list may contain arbitrary tokens with the exception of the terminator token (comma resp. right parenthesis) and <itemize> <item>end-of-line <item>end-of-file </itemize> The token lists may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). Often a macro parameter is used for any of the token lists. Please note that the function does only compare tokens, not token attributes. So any number is equal to any other number, regardless of the actual value. The same is true for strings. If you need to compare tokens <em/and/ token attributes, use the <tt><ref id=".XMATCH" name=".XMATCH"></tt> function. Example: Assume the macro <tt/ASR/, that will shift right the accumulator by one, while honoring the sign bit. The builtin processor instructions will allow an optional "A" for accu addressing for instructions like <tt/ROL/ and <tt/ROR/. We will use the <tt><ref id=".MATCH" name=".MATCH"></tt> function to check for this and print and error for invalid calls. <tscreen><verb> .macro asr arg .if (.not .blank(arg)) .and (.not .match ({arg}, a)) .error "Syntax error" .endif cmp #$80 ; Bit 7 into carry lsr a ; Shift carry into bit 7 .endmacro </verb></tscreen> The macro will only accept no arguments, or one argument that must be the reserved keyword "A". See: <tt><ref id=".XMATCH" name=".XMATCH"></tt> <sect1><tt>.MAX</tt><label id=".MAX"><p> Builtin function. The result is the larger of two values. The syntax is <tscreen><verb> .MAX (<value #1>, <value #2>) </verb></tscreen> Example: <tscreen><verb> ; Reserve space for the larger of two data blocks savearea: .res .max (.sizeof (foo), .sizeof (bar)) </verb></tscreen> See: <tt><ref id=".MIN" name=".MIN"></tt> <sect1><tt>.MID</tt><label id=".MID"><p> Builtin function. Takes a starting index, a count and a token list as arguments. Will return part of the token list. Syntax: <tscreen><verb> .MID (<int expr>, <int expr>, <token list>) </verb></tscreen> The first integer expression gives the starting token in the list (the first token has index 0). The second integer expression gives the number of tokens to extract from the token list. The third argument is the token list itself. The token list may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). Example: To check in a macro if the given argument has a '<tt/#/' as first token (immediate addressing mode), use something like this: <tscreen><verb> .macro ldax arg ... .if (.match (.mid (0, 1, {arg}), #)) ; ldax called with immediate operand ... .endif ... .endmacro </verb></tscreen> See also the <tt><ref id=".LEFT" name=".LEFT"></tt> and <tt><ref id=".RIGHT" name=".RIGHT"></tt> builtin functions. <sect1><tt>.MIN</tt><label id=".MIN"><p> Builtin function. The result is the smaller of two values. The syntax is <tscreen><verb> .MIN (<value #1>, <value #2>) </verb></tscreen> Example: <tscreen><verb> ; Reserve space for some data, but 256 bytes maximum savearea: .res .min (.sizeof (foo), 256) </verb></tscreen> See: <tt><ref id=".MAX" name=".MAX"></tt> <sect1><tt>.REF, .REFERENCED</tt><label id=".REFERENCED"><p> Builtin function. The function expects an identifier as argument in parentheses. The argument is evaluated, and the function yields "true" if the identifier is a symbol that has already been referenced somewhere in the source file up to the current position. Otherwise the function yields false. As an example, the <tt><ref id=".IFREF" name=".IFREF"></tt> statement may be replaced by <tscreen><verb> .if .referenced(a) </verb></tscreen> See: <tt><ref id=".DEFINED" name=".DEFINED"></tt> <sect1><tt>.RIGHT</tt><label id=".RIGHT"><p> Builtin function. Extracts the right part of a given token list. Syntax: <tscreen><verb> .RIGHT (<int expr>, <token list>) </verb></tscreen> The first integer expression gives the number of tokens to extract from the token list. The second argument is the token list itself. The token list may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). See also the <tt><ref id=".LEFT" name=".LEFT"></tt> and <tt><ref id=".MID" name=".MID"></tt> builtin functions. <sect1><tt>.SIZEOF</tt><label id=".SIZEOF"><p> <tt/.SIZEOF()/ is a pseudo function that returns the size of its argument. The argument can be a struct/union, a struct member, a scope/procedure, or a label. In the case of a procedure or label, its size is defined by the amount of data placed in the segment where the label is relative to. If a line of code switches segments (for example, in a macro), data placed in other segments does not count for the size. Please note that a symbol or scope must exist before it can be used together with <tt/.SIZEOF()/ (that may get relaxed later, but always will be true for scopes). A scope has preference over a symbol with the same name; so, if the last part of a name represents both a scope and a symbol, then the scope is chosen over the symbol. After the following code: <tscreen><verb> .struct Point ; Struct size = 4 xcoord .word ycoord .word .endstruct P: .tag Point ; Declare a point @P: .tag Point ; Declare another point .code .proc Code nop .proc Inner nop .endproc nop .endproc .proc Data .data ; Segment switch!!! .res 4 .endproc </verb></tscreen> <descrip> <tag><tt/.sizeof(Point)/</tag> will have the value 4, because this is the size of struct <tt/Point/. <tag><tt/.sizeof(Point::xcoord)/</tag> will have the value 2, because this is the size of the member <tt/xcoord/ in struct <tt/Point/. <tag><tt/.sizeof(P)/</tag> will have the value 4, this is the size of the data declared on the same source line as the label <tt/P/, which is in the same segment that <tt/P/ is relative to. <tag><tt/.sizeof(@P)/</tag> will have the value 4, see above. The example demonstrates that <tt/.SIZEOF/ does also work for cheap local symbols. <tag><tt/.sizeof(Code)/</tag> will have the value 3, since this is amount of data emitted into the code segment, the segment that was active when <tt/Code/ was entered. Note that this value includes the amount of data emitted in child scopes (in this case <tt/Code::Inner/). <tag><tt/.sizeof(Code::Inner)/</tag> will have the value 1 as expected. <tag><tt/.sizeof(Data)/</tag> will have the value 0. Data is emitted within the scope <tt/Data/, but since the segment is switched after entry, this data is emitted into another segment. </descrip> <sect1><tt>.SPRINTF</tt><label id=".SPRINTF"><p> Builtin function. It expects a format string as first argument. The number and type of the following arguments depend on the format string. The format string is similar to the one of the C <tt/printf/ function. Missing things are: Length modifiers, variable width. The result of the function is a string. Example: <tscreen><verb> num = 3 ; Generate an identifier: .ident (.sprintf ("%s%03d", "label", num)): </verb></tscreen> <sect1><tt>.STRAT</tt><label id=".STRAT"><p> Builtin function. The function accepts a string and an index as arguments and returns the value of the character at the given position as an integer value. The index is zero based. Example: <tscreen><verb> .macro M Arg ; Check if the argument string starts with '#' .if (.strat (Arg, 0) = '#') ... .endif .endmacro </verb></tscreen> <sect1><tt>.STRING</tt><label id=".STRING"><p> Builtin function. The function accepts an argument in parentheses and converts this argument into a string constant. The argument may be an identifier, or a constant numeric value. Since you can use a string in the first place, the use of the function may not be obvious. However, it is useful in macros, or more complex setups. Example: <tscreen><verb> ; Emulate other assemblers: .macro section name .segment .string(name) .endmacro </verb></tscreen> <sect1><tt>.STRLEN</tt><label id=".STRLEN"><p> Builtin function. The function accepts a string argument in parentheses and evaluates to the length of the string. Example: The following macro encodes a string as a pascal style string with a leading length byte. <tscreen><verb> .macro PString Arg .byte .strlen(Arg), Arg .endmacro </verb></tscreen> <sect1><tt>.TCOUNT</tt><label id=".TCOUNT"><p> Builtin function. The function accepts a token list in parentheses. The function result is the number of tokens given as argument. The token list may optionally be enclosed into curly braces which are not considered part of the list and not counted. Enclosement in curly braces allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). Example: The <tt/ldax/ macro accepts the '#' token to denote immediate addressing (as with the normal 6502 instructions). To translate it into two separate 8 bit load instructions, the '#' token has to get stripped from the argument: <tscreen><verb> .macro ldax arg .if (.match (.mid (0, 1, {arg}), #)) ; ldax called with immediate operand lda #<(.right (.tcount ({arg})-1, {arg})) ldx #>(.right (.tcount ({arg})-1, {arg})) .else ... .endif .endmacro </verb></tscreen> <sect1><tt>.XMATCH</tt><label id=".XMATCH"><p> Builtin function. Matches two token lists against each other. This is most useful within macros, since macros are not stored as strings, but as lists of tokens. The syntax is <tscreen><verb> .XMATCH(<token list #1>, <token list #2>) </verb></tscreen> Both token list may contain arbitrary tokens with the exception of the terminator token (comma resp. right parenthesis) and <itemize> <item>end-of-line <item>end-of-file </itemize> The token lists may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the list (the closing right paren in the given case). Often a macro parameter is used for any of the token lists. The function compares tokens <em/and/ token values. If you need a function that just compares the type of tokens, have a look at the <tt><ref id=".MATCH" name=".MATCH"></tt> function. See: <tt><ref id=".MATCH" name=".MATCH"></tt> <sect>Control commands<label id="control-commands"><p> Here's a list of all control commands and a description, what they do: <sect1><tt>.A16</tt><label id=".A16"><p> Valid only in 65816 mode. Assume the accumulator is 16 bit. Note: This command will not emit any code, it will tell the assembler to create 16 bit operands for immediate accumulator addressing mode. See also: <tt><ref id=".SMART" name=".SMART"></tt> <sect1><tt>.A8</tt><label id=".A8"><p> Valid only in 65816 mode. Assume the accumulator is 8 bit. Note: This command will not emit any code, it will tell the assembler to create 8 bit operands for immediate accu addressing mode. See also: <tt><ref id=".SMART" name=".SMART"></tt> <sect1><tt>.ADDR</tt><label id=".ADDR"><p> Define word sized data. In 6502 mode, this is an alias for <tt/.WORD/ and may be used for better readability if the data words are address values. In 65816 mode, the address is forced to be 16 bit wide to fit into the current segment. See also <tt><ref id=".FARADDR" name=".FARADDR"></tt>. The command must be followed by a sequence of (not necessarily constant) expressions. Example: <tscreen><verb> .addr $0D00, $AF13, _Clear </verb></tscreen> See: <tt><ref id=".FARADDR" name=".FARADDR"></tt>, <tt><ref id=".WORD" name=".WORD"></tt> <sect1><tt>.ALIGN</tt><label id=".ALIGN"><p> Align data to a given boundary. The command expects a constant integer argument in the range 1 ... 65536, plus an optional second argument in byte range. If there is a second argument, it is used as fill value, otherwise the value defined in the linker configuration file is used (the default for this value is zero). <tt/.ALIGN/ will insert fill bytes, and the number of fill bytes depend of the final address of the segment. <tt/.ALIGN/ cannot insert a variable number of bytes, since that would break address calculations within the module. So each <tt/.ALIGN/ expects the segment to be aligned to a multiple of the alignment, because that allows the number of fill bytes to be calculated in advance by the assembler. You are therefore required to specify a matching alignment for the segment in the linker config. The linker will output a warning if the alignment of the segment is less than what is necessary to have a correct alignment in the object file. Example: <tscreen><verb> .align 256 </verb></tscreen> Some unexpected behaviour might occur if there are multiple <tt/.ALIGN/ commands with different arguments. To allow the assembler to calculate the number of fill bytes in advance, the alignment of the segment must be a multiple of each of the alignment factors. This may result in unexpectedly large alignments for the segment within the module. Example: <tscreen><verb> .align 15 .byte 15 .align 18 .byte 18 </verb></tscreen> For the assembler to be able to align correctly, the segment must be aligned to the least common multiple of 15 and 18 which is 90. The assembler will calculate this automatically and will mark the segment with this value. Unfortunately, the combined alignment may get rather large without the user knowing about it, wasting space in the final executable. If we add another alignment to the example above <tscreen><verb> .align 15 .byte 15 .align 18 .byte 18 .align 251 .byte 0 </verb></tscreen> the assembler will force a segment alignment to the least common multiple of 15, 18 and 251 - which is 22590. To protect the user against errors, when the combined alignment is larger than the explicitly requested alignments, the assembler will issue a warning if it also exceeds 256. The command line option <tt><ref id="option--large-alignment" name="--large-alignment"></tt> will disable this warning. Please note that with only alignments that are a power of two, a warning will never occur, because the least common multiple of powers to the same base is always simply the larger one. <sect1><tt>.ASCIIZ</tt><label id=".ASCIIZ"><p> Define a string with a trailing zero. Example: <tscreen><verb> Msg: .asciiz "Hello world" </verb></tscreen> This will put the string "Hello world" followed by a binary zero into the current segment. There may be more strings separated by commas, but the binary zero is only appended once (after the last one). Strings will be translated using the current character mapping definition. See: <tt><ref id=".BYTE" name=".BYTE"></tt>,<tt><ref id=".CHARMAP" name=".CHARMAP"></tt>, <tt><ref id=".LITERAL" name=".LITERAL"></tt> <sect1><tt>.ASSERT</tt><label id=".ASSERT"><p> Add an assertion. The command is followed by an expression, an action specifier, and an optional message that is output in case the assertion fails. If no message was given, the string "Assertion failed" is used. The action specifier may be one of <tt/warning/, <tt/error/, <tt/ldwarning/ or <tt/lderror/. In the former two cases, the assertion is evaluated by the assembler if possible, and in any case, it's also passed to the linker in the object file (if one is generated). The linker will then evaluate the expression when segment placement has been done. Example: <tscreen><verb> .assert * = $8000, error, "Code not at $8000" </verb></tscreen> The example assertion will check that the current location is at $8000, when the output file is written, and abort with an error if this is not the case. More complex expressions are possible. The action specifier <tt/warning/ outputs a warning, while the <tt/error/ specifier outputs an error message. In the latter case, generation of the output file is suppressed in both the assembler and linker. <sect1><tt>.AUTOIMPORT</tt><label id=".AUTOIMPORT"><p> Is followed by a plus or a minus character. When switched on (using a +), undefined symbols are automatically marked as import instead of giving errors. When switched off (which is the default so this does not make much sense), this does not happen and an error message is displayed. The state of the autoimport flag is evaluated when the complete source was translated, before outputting actual code, so it is <em/not/ possible to switch this feature on or off for separate sections of code. The last setting is used for all symbols. You should probably not use this switch because it delays error messages about undefined symbols until the link stage. The cc65 compiler (which is supposed to produce correct assembler code in all circumstances, something which is not true for most assembler programmers) will insert this command to avoid importing each and every routine from the runtime library. Example: <tscreen><verb> .autoimport + ; Switch on auto import </verb></tscreen> <sect1><tt>.BANKBYTES</tt><label id=".BANKBYTES"><p> Define byte sized data by extracting only the bank byte (that is, bits 16-23) from each expression. This is equivalent to <tt><ref id=".BYTE" name=".BYTE"></tt> with the operator '^' prepended to each expression in its list. Example: <tscreen><verb> .define MyTable TableItem0, TableItem1, TableItem2, TableItem3 TableLookupLo: .lobytes MyTable TableLookupHi: .hibytes MyTable TableLookupBank: .bankbytes MyTable </verb></tscreen> which is equivalent to <tscreen><verb> TableLookupLo: .byte <TableItem0, <TableItem1, <TableItem2, <TableItem3 TableLookupHi: .byte >TableItem0, >TableItem1, >TableItem2, >TableItem3 TableLookupBank: .byte ^TableItem0, ^TableItem1, ^TableItem2, ^TableItem3 </verb></tscreen> See also: <tt><ref id=".BYTE" name=".BYTE"></tt>, <tt><ref id=".HIBYTES" name=".HIBYTES"></tt>, <tt><ref id=".LOBYTES" name=".LOBYTES"></tt> <sect1><tt>.BSS</tt><label id=".BSS"><p> Switch to the BSS segment. The name of the BSS segment is always "BSS", so this is a shortcut for <tscreen><verb> .segment "BSS" </verb></tscreen> See also the <tt><ref id=".SEGMENT" name=".SEGMENT"></tt> command. <sect1><tt>.BYT, .BYTE</tt><label id=".BYTE"><p> Define byte sized data. Must be followed by a sequence of (byte ranged) expressions or strings. Strings will be translated using the current character mapping definition. Example: <tscreen><verb> .byte "Hello " .byt "world", $0D, $00 </verb></tscreen> See: <tt><ref id=".ASCIIZ" name=".ASCIIZ"></tt>,<tt><ref id=".CHARMAP" name=".CHARMAP"></tt> <tt><ref id=".LITERAL" name=".LITERAL"></tt> <sect1><tt>.CASE</tt><label id=".CASE"><p> Switch on or off case sensitivity on identifiers. The default is off (that is, identifiers are case sensitive), but may be changed by the -i switch on the command line. The command can be followed by a '+' or '-' character to switch the option on or off respectively. Example: <tscreen><verb> .case - ; Identifiers are not case sensitive </verb></tscreen> <sect1><tt>.CHARMAP</tt><label id=".CHARMAP"><p> Apply a custom mapping for characters for the commands <tt><ref id=".ASCIIZ" name=".ASCIIZ"></tt> and <tt><ref id=".BYTE" name=".BYTE"></tt>. The command is followed by two numbers. The first one is the index of the source character (range 0..255); the second one is the mapping (range 0..255). The mapping applies to all character and string constants <em/when/ they generate output; and, overrides a mapping table specified with the <tt><ref id="option-t" name="-t"></tt> command line switch. Example: <tscreen><verb> .charmap $41, $61 ; Map 'A' to 'a' </verb></tscreen> <sect1><tt>.CODE</tt><label id=".CODE"><p> Switch to the CODE segment. The name of the CODE segment is always "CODE", so this is a shortcut for <tscreen><verb> .segment "CODE" </verb></tscreen> See also the <tt><ref id=".SEGMENT" name=".SEGMENT"></tt> command. <sect1><tt>.CONDES</tt><label id=".CONDES"><p> Export a symbol and mark it in a special way. The linker is able to build tables of all such symbols. This may be used to automatically create a list of functions needed to initialize linked library modules. Note: The linker has a feature to build a table of marked routines, but it is your code that must call these routines, so just declaring a symbol with <tt/.CONDES/ does nothing by itself. All symbols are exported as an absolute (16 bit) symbol. You don't need to use an additional <tt><ref id=".EXPORT" name=".EXPORT"></tt> statement, this is implied by <tt/.CONDES/. <tt/.CONDES/ is followed by the type, which may be <tt/constructor/, <tt/destructor/ or a numeric value between 0 and 6 (where 0 is the same as specifying <tt/constructor/ and 1 is equal to specifying <tt/destructor/). The <tt><ref id=".CONSTRUCTOR" name=".CONSTRUCTOR"></tt>, <tt><ref id=".DESTRUCTOR" name=".DESTRUCTOR"></tt> and <tt><ref id=".INTERRUPTOR" name=".INTERRUPTOR"></tt> commands are actually shortcuts for <tt/.CONDES/ with a type of <tt/constructor/ resp. <tt/destructor/ or <tt/interruptor/. After the type, an optional priority may be specified. Higher numeric values mean higher priority. If no priority is given, the default priority of 7 is used. Be careful when assigning priorities to your own module constructors so they won't interfere with the ones in the cc65 library. Example: <tscreen><verb> .condes ModuleInit, constructor .condes ModInit, 0, 16 </verb></tscreen> See the <tt><ref id=".CONSTRUCTOR" name=".CONSTRUCTOR"></tt>, <tt><ref id=".DESTRUCTOR" name=".DESTRUCTOR"></tt> and <tt><ref id=".INTERRUPTOR" name=".INTERRUPTOR"></tt> commands and the separate section <ref id="condes" name="Module constructors/destructors"> explaining the feature in more detail. <sect1><tt>.CONSTRUCTOR</tt><label id=".CONSTRUCTOR"><p> Export a symbol and mark it as a module constructor. This may be used together with the linker to build a table of constructor subroutines that are called by the startup code. Note: The linker has a feature to build a table of marked routines, but it is your code that must call these routines, so just declaring a symbol as constructor does nothing by itself. A constructor is always exported as an absolute (16 bit) symbol. You don't need to use an additional <tt/.export/ statement, this is implied by <tt/.constructor/. It may have an optional priority that is separated by a comma. Higher numeric values mean a higher priority. If no priority is given, the default priority of 7 is used. Be careful when assigning priorities to your own module constructors so they won't interfere with the ones in the cc65 library. Example: <tscreen><verb> .constructor ModuleInit .constructor ModInit, 16 </verb></tscreen> See the <tt><ref id=".CONDES" name=".CONDES"></tt> and <tt><ref id=".DESTRUCTOR" name=".DESTRUCTOR"></tt> commands and the separate section <ref id="condes" name="Module constructors/destructors"> explaining the feature in more detail. <sect1><tt>.DATA</tt><label id=".DATA"><p> Switch to the DATA segment. The name of the DATA segment is always "DATA", so this is a shortcut for <tscreen><verb> .segment "DATA" </verb></tscreen> See also the <tt><ref id=".SEGMENT" name=".SEGMENT"></tt> command. <sect1><tt>.DBYT</tt><label id=".DBYT"><p> Define word sized data with the hi and lo bytes swapped (use <tt/.WORD/ to create word sized data in native 65XX format). Must be followed by a sequence of (word ranged) expressions. Example: <tscreen><verb> .dbyt $1234, $4512 </verb></tscreen> This will emit the bytes <tscreen><verb> $12 $34 $45 $12 </verb></tscreen> into the current segment in that order. <sect1><tt>.DEBUGINFO</tt><label id=".DEBUGINFO"><p> Switch on or off debug info generation. The default is off (that is, the object file will not contain debug infos), but may be changed by the -g switch on the command line. The command can be followed by a '+' or '-' character to switch the option on or off respectively. Example: <tscreen><verb> .debuginfo + ; Generate debug info </verb></tscreen> <sect1><tt>.DEFINE</tt><label id=".DEFINE"><p> Start a define style macro definition. The command is followed by an identifier (the macro name) and optionally by a list of formal arguments in parentheses. Please note that <tt/.DEFINE/ shares most disadvantages with its C counterpart, so the general advice is, <bf/NOT/ do use <tt/.DEFINE/ if you don't have to. See also the <tt><ref id=".UNDEFINE" name=".UNDEFINE"></tt> command and section <ref id="macros" name="Macros">. <sect1><tt>.DELMAC, .DELMACRO</tt><label id=".DELMACRO"><p> Delete a classic macro (defined with <tt><ref id=".MACRO" name=".MACRO"></tt>) . The command is followed by the name of an existing macro. Its definition will be deleted together with the name. If necessary, another macro with this name may be defined later. See: <tt><ref id=".ENDMACRO" name=".ENDMACRO"></tt>, <tt><ref id=".EXITMACRO" name=".EXITMACRO"></tt>, <tt><ref id=".MACRO" name=".MACRO"></tt> See also section <ref id="macros" name="Macros">. <sect1><tt>.DESTRUCTOR</tt><label id=".DESTRUCTOR"><p> Export a symbol and mark it as a module destructor. This may be used together with the linker to build a table of destructor subroutines that are called by the startup code. Note: The linker has a feature to build a table of marked routines, but it is your code that must call these routines, so just declaring a symbol as constructor does nothing by itself. A destructor is always exported as an absolute (16 bit) symbol. You don't need to use an additional <tt/.export/ statement, this is implied by <tt/.destructor/. It may have an optional priority that is separated by a comma. Higher numerical values mean a higher priority. If no priority is given, the default priority of 7 is used. Be careful when assigning priorities to your own module destructors so they won't interfere with the ones in the cc65 library. Example: <tscreen><verb> .destructor ModuleDone .destructor ModDone, 16 </verb></tscreen> See the <tt><ref id=".CONDES" name=".CONDES"></tt> and <tt><ref id=".CONSTRUCTOR" name=".CONSTRUCTOR"></tt> commands and the separate section <ref id="condes" name="Module constructors/destructors"> explaining the feature in more detail. <sect1><tt>.DWORD</tt><label id=".DWORD"><p> Define dword sized data (4 bytes) Must be followed by a sequence of expressions. Example: <tscreen><verb> .dword $12344512, $12FA489 </verb></tscreen> <sect1><tt>.ELSE</tt><label id=".ELSE"><p> Conditional assembly: Reverse the current condition. <sect1><tt>.ELSEIF</tt><label id=".ELSEIF"><p> Conditional assembly: Reverse current condition and test a new one. <sect1><tt>.END</tt><label id=".END"><p> Forced end of assembly. Assembly stops at this point, even if the command is read from an include file. <sect1><tt>.ENDENUM</tt><label id=".ENDENUM"><p> End a <tt><ref id=".ENUM" name=".ENUM"></tt> declaration. <sect1><tt>.ENDIF</tt><label id=".ENDIF"><p> Conditional assembly: Close a <tt><ref id=".IF" name=".IF..."></tt> or <tt><ref id=".ELSE" name=".ELSE"></tt> branch. <sect1><tt>.ENDMAC, .ENDMACRO</tt><label id=".ENDMACRO"><p> Marks the end of a macro definition. Note, <tt>.ENDMACRO</tt> should be on its own line to successfully end the macro definition. It is possible to use <tt><ref id=".DEFINE" name=".DEFINE"></tt> to create a symbol that references <tt>.ENDMACRO</tt> without ending the macro definition. Example: <tscreen><verb> .macro new_mac .define startmac .macro .define endmac .endmacro .endmacro </verb></tscreen> See: <tt><ref id=".DELMACRO" name=".DELMACRO"></tt>, <tt><ref id=".EXITMACRO" name=".EXITMACRO"></tt>, <tt><ref id=".MACRO" name=".MACRO"></tt> See also section <ref id="macros" name="Macros">. <sect1><tt>.ENDPROC</tt><label id=".ENDPROC"><p> End of the local lexical level (see <tt><ref id=".PROC" name=".PROC"></tt>). <sect1><tt>.ENDREP, .ENDREPEAT</tt><label id=".ENDREPEAT"><p> End a <tt><ref id=".REPEAT" name=".REPEAT"></tt> block. <sect1><tt>.ENDSCOPE</tt><label id=".ENDSCOPE"><p> End of the local lexical level (see <tt/<ref id=".SCOPE" name=".SCOPE">/). <sect1><tt>.ENDSTRUCT</tt><label id=".ENDSTRUCT"><p> Ends a struct definition. See the <tt/<ref id=".STRUCT" name=".STRUCT">/ command and the separate section named <ref id="structs" name=""Structs and unions"">. <sect1><tt>.ENDUNION</tt><label id=".ENDUNION"><p> Ends a union definition. See the <tt/<ref id=".UNION" name=".UNION">/ command and the separate section named <ref id="structs" name=""Structs and unions"">. <sect1><tt>.ENUM</tt><label id=".ENUM"><p> Start an enumeration. This directive is very similar to the C <tt/enum/ keyword. If a name is given, a new scope is created for the enumeration, otherwise the enumeration members are placed in the enclosing scope. In the enumeration body, symbols are declared. The first symbol has a value of zero, and each following symbol will get the value of the preceding, plus one. That behaviour may be overridden by an explicit assignment. Two symbols may have the same value. Example: <tscreen><verb> .enum errorcodes no_error file_error parse_error .endenum </verb></tscreen> The above example will create a new scope named <tt/errorcodes/ with three symbols in it that get the values 0, 1, and 2 respectively. Another way to write that would have been: <tscreen><verb> .scope errorcodes no_error = 0 file_error = 1 parse_error = 2 .endscope </verb></tscreen> Please note that explicit scoping must be used to access the identifiers: <tscreen><verb> .word errorcodes::no_error </verb></tscreen> A more complex example: <tscreen><verb> .enum EUNKNOWN = -1 EOK EFILE EBUSY EAGAIN EWOULDBLOCK = EAGAIN .endenum </verb></tscreen> In that example, the enumeration does not have a name, which means that the members will be visible in the enclosing scope, and can be used in that scope without explicit scoping. The first member (<tt/EUNKNOWN/) has the value -1. The values for the following members are incremented by one; so, <tt/EOK/ would be zero, and so on. <tt/EWOULDBLOCK/ is an alias for <tt/EAGAIN/; so, it has an override for the value, using an already defined symbol. <sect1><tt>.ERROR</tt><label id=".ERROR"><p> Force an assembly error. The assembler will output an error message preceded by "User error". Assembly is continued but no object file will generated. This command may be used to check for initial conditions that must be set before assembling a source file. Example: <tscreen><verb> .if foo = 1 ... .elseif bar = 1 ... .else .error "Must define foo or bar!" .endif </verb></tscreen> See also: <tt><ref id=".FATAL" name=".FATAL"></tt>, <tt><ref id=".OUT" name=".OUT"></tt>, <tt><ref id=".WARNING" name=".WARNING"></tt> <sect1><tt>.EXITMAC, .EXITMACRO</tt><label id=".EXITMACRO"><p> Abort a macro expansion immediately. This command is often useful in recursive macros. See: <tt><ref id=".DELMACRO" name=".DELMACRO"></tt>, <tt><ref id=".ENDMACRO" name=".ENDMACRO"></tt>, <tt><ref id=".MACRO" name=".MACRO"></tt> See also section <ref id="macros" name="Macros">. <sect1><tt>.EXPORT</tt><label id=".EXPORT"><p> Make symbols accessible from other modules. Must be followed by a comma separated list of symbols to export, with each one optionally followed by an address specification and (also optional) an assignment. Using an additional assignment in the export statement allows to define and export a symbol in one statement. The default is to export the symbol with the address size it actually has. The assembler will issue a warning, if the symbol is exported with an address size smaller than the actual address size. Examples: <tscreen><verb> .export foo .export bar: far .export foobar: far = foo * bar .export baz := foobar, zap: far = baz - bar </verb></tscreen> As with constant definitions, using <tt/:=/ instead of <tt/=/ marks the symbols as a label. See: <tt><ref id=".EXPORTZP" name=".EXPORTZP"></tt> <sect1><tt>.EXPORTZP</tt><label id=".EXPORTZP"><p> Make symbols accessible from other modules. Must be followed by a comma separated list of symbols to export. The exported symbols are explicitly marked as zero page symbols. An assignment may be included in the <tt/.EXPORTZP/ statement. This allows to define and export a symbol in one statement. Examples: <tscreen><verb> .exportzp foo, bar .exportzp baz := $02 </verb></tscreen> See: <tt><ref id=".EXPORT" name=".EXPORT"></tt> <sect1><tt>.FARADDR</tt><label id=".FARADDR"><p> Define far (24 bit) address data. The command must be followed by a sequence of (not necessarily constant) expressions. Example: <tscreen><verb> .faraddr DrawCircle, DrawRectangle, DrawHexagon </verb></tscreen> See: <tt><ref id=".ADDR" name=".ADDR"></tt> <sect1><tt>.FATAL</tt><label id=".FATAL"><p> Force an assembly error and terminate assembly. The assembler will output an error message preceded by "User error" and will terminate assembly immediately. This command may be used to check for initial conditions that must be set before assembling a source file. Example: <tscreen><verb> .if foo = 1 ... .elseif bar = 1 ... .else .fatal "Must define foo or bar!" .endif </verb></tscreen> See also: <tt><ref id=".ERROR" name=".ERROR"></tt>, <tt><ref id=".OUT" name=".OUT"></tt>, <tt><ref id=".WARNING" name=".WARNING"></tt> <sect1><tt>.FEATURE</tt><label id=".FEATURE"><p> This directive may be used to enable one or more compatibility features of the assembler. While the use of <tt/.FEATURE/ should be avoided when possible, it may be useful when porting sources written for other assemblers. After the feature name an optional '+' or '-' may specify whether to enable or disable the feature (enable if omitted). Multiple features may be enabled, separated by commas. Examples: <tscreen><verb> ; enable c_comments .feature c_comments .feature c_comments + ; enable force_range, disable underline_in_numbers, enable labels_without_colons .feature force_range, underline_in_numbers -, labels_without_colons + .feature force_range +, underline_in_numbers off, labels_without_colons on </verb></tscreen> The following features are available: <descrip> <tag><tt>at_in_identifiers</tt><label id="at_in_identifiers"></tag> Accept the at character ('@') as a valid character in identifiers. The at character is not allowed to start an identifier, even with this feature enabled. <tag><tt>bracket_as_indirect</tt><label id="bracket_as_indirect"></tag> Use <tt>[]</tt> instead of <tt>()</tt> for the indirect addressing modes. Example: <tscreen><verb> lda [$82] lda [$82,x] lda [$82],y jmp [$fffe] jmp [table,x] </verb></tscreen> <em/Note:/ This should not be used in 65186 mode because it conflicts with the 65816 instruction syntax for far addressing. See the section covering <tt/<ref id="address-sizes" name="address sizes">/ for more information. <tag><tt>c_comments</tt><label id="c_comments"></tag> Allow C like comments using <tt>/*</tt> and <tt>*/</tt> as left and right comment terminators. Note that C comments may not be nested. There's also a pitfall when using C like comments: All statements must be terminated by "end-of-line". Using C like comments, it is possible to hide the newline, which results in error messages. See the following non working example: <tscreen><verb> lda #$00 /* This comment hides the newline */ sta $82 </verb></tscreen> <tag><tt>dollar_in_identifiers</tt><label id="dollar_in_identifiers"></tag> Accept the dollar sign ('$') as a valid character in identifiers. The dollar character is not allowed to start an identifier, even with this feature enabled. <tag><tt>dollar_is_pc</tt><label id="dollar_is_pc"></tag> The dollar sign may be used as an alias for the star ('*'), which gives the value of the current PC in expressions. Note: Assignment to the pseudo variable is not allowed. <tag><tt>force_range</tt><label id="force_range"></tag> Force expressions into their valid range for immediate addressing and storage operators like <tt><ref id=".BYTE" name=".BYTE"></tt> and <tt><ref id=".WORD" name=".WORD"></tt>. Be very careful with this one, since it will completely disable error checks. <tag><tt>labels_without_colons</tt><label id="labels_without_colons"></tag> Allow labels without a trailing colon. These labels are only accepted, if they start at the beginning of a line (no leading white space). <tag><tt>leading_dot_in_identifiers</tt><label id="leading_dot_in_identifiers"></tag> Accept the dot ('.') as the first character of an identifier. This may be used for example to create macro names that start with a dot emulating control directives of other assemblers. Note however, that none of the reserved keywords built into the assembler, that starts with a dot, may be overridden. When using this feature, you may also get into trouble if later versions of the assembler define new keywords starting with a dot. <tag><tt>line_continuations</tt><label id="line_continuations"></tag> Switch on or off line continuations using the backslash character before a newline. The option is off by default. Note: Line continuations do not work in a comment. A backslash at the end of a comment is treated as part of the comment and does not trigger line continuation. Example: <tscreen><verb> .feature line_continuations + ; Allow line continuations lda \ #$20 ; This is legal now </verb></tscreen> For backward compatibility reasons, the <tt>.LINECONT +</tt> control command is also supported and enables the same feature. <tag><tt>long_jsr_jmp_rts</tt><label id="long_jsr_jmp_rts"></tag> Affects 65816 mode only. Allows <tt>jsr</tt> and <tt>jmp</tt> to produce long jumps if the target address has been previously declared in a <tt>far</tt> segment, or imported as <tt>far</tt>. Otherwise <tt>jsl</tt> and <tt>jml</tt> must be used instead. Also allows <tt><ref id=".SMART" name=".SMART"></tt> to convert <tt>rts</tt> to a long return <tt>rtl</tt> when the enclosing scope or memory model indicates returning from a <tt>far</tt> procedure. This permits compatibility with the old behavior of this assembler, or other assemblers which similarly allowed <tt>jsr</tt> and <tt>jmp</tt> to be used this way. <tag><tt>loose_char_term</tt><label id="loose_char_term"></tag> Accept single quotes as well as double quotes as terminators for char constants. <tag><tt>loose_string_term</tt><label id="loose_string_term"></tag> Accept single quotes as well as double quotes as terminators for string constants. <tag><tt>missing_char_term</tt><label id="missing_char_term"></tag> Accept single quoted character constants where the terminating quote is missing. <tscreen><verb> lda #'a </verb></tscreen> <em/Note:/ This does not work in conjunction with <tt/.FEATURE loose_string_term/, since in this case the input would be ambiguous. <tag><tt>org_per_seg</tt><label id="org_per_seg"></tag> This feature makes relocatable/absolute mode local to the current segment. Using <tt><ref id=".ORG" name=".ORG"></tt> when <tt/org_per_seg/ is in effect will only enable absolute mode for the current segment. Dito for <tt><ref id=".RELOC" name=".RELOC"></tt>. <tag><tt>pc_assignment</tt><label id="pc_assignment"></tag> Allow assignments to the PC symbol ('*' or '$' if <tt/dollar_is_pc/ is enabled). Such an assignment is handled identical to the <tt><ref id=".ORG" name=".ORG"></tt> command (which is usually not needed, so just removing the lines with the assignments may also be an option when porting code written for older assemblers). <tag><tt>string_escapes</tt><label id="string_escapes"></tag> Allow C-style backslash escapes within string constants to embed special characters. The following escapes are accepted: <itemize> <item><tt>\\</tt> backslash (<tt>$5C</tt>) <item><tt>\'</tt> single quote (<tt>$27</tt>) <item><tt>\"</tt> double quote (<tt>$22</tt>) <item><tt>\t</tt> tab (<tt>$09</tt>) <item><tt>\r</tt> carriage return (<tt>$0D</tt>) <item><tt>\n</tt> newline (<tt>$0A</tt>) <item><tt>\xNN</tt> (<tt>$NN</tt>) </itemize> Note that string escapes are converted to platform-specific characters in the same way that other characters are converted. <tag><tt>ubiquitous_idents</tt><label id="ubiquitous_idents"></tag> Allow the use of instructions names as names for macros and symbols. This makes it possible to "overload" instructions by defining a macro with the same name. This does also make it possible to introduce hard to find errors in your code, so be careful! <tag><tt>underline_in_numbers</tt><label id="underline_in_numbers"></tag> Allow underlines within numeric constants. These may be used for grouping the digits of numbers for easier reading. Example: <tscreen><verb> .feature underline_in_numbers .word %1100001110100101 .word %1100_0011_1010_0101 ; Identical but easier to read </verb></tscreen> </descrip> It is also possible to specify features on the command line using the <tt><ref id="option--feature" name="--feature"></tt> command line option. This is useful when translating sources written for older assemblers, when you don't want to change the source code. As an example, to translate sources written for Andre Fachats xa65 assembler, the features <verb> labels_without_colons, pc_assignment, loose_char_term </verb> may be helpful. They do not make ca65 completely compatible, so you may not be able to translate the sources without changes, even when enabling these features. However, I have found several sources that translate without problems when enabling these features on the command line. <sect1><tt>.FILEOPT, .FOPT</tt><label id=".FOPT"><p> Insert an option string into the object file. There are two forms of this command, one specifies the option by a keyword, the second specifies it as a number. Since usage of the second one needs knowledge of the internal encoding, its use is not recommended and I will only describe the first form here. The command is followed by one of the keywords <tscreen><verb> author comment compiler </verb></tscreen> a comma and a string. The option is written into the object file together with the string value. This is currently unidirectional and there is no way to actually use these options once they are in the object file. Examples: <tscreen><verb> .fileopt comment, "Code stolen from my brother" .fileopt compiler, "BASIC 2.0" .fopt author, "J. R. User" </verb></tscreen> <sect1><tt>.FORCEIMPORT</tt><label id=".FORCEIMPORT"><p> Import an absolute symbol from another module. The command is followed by a comma separated list of symbols to import. The command is similar to <tt> <ref id=".IMPORT" name=".IMPORT"></tt>, but the import reference is always written to the generated object file, even if the symbol is never referenced (<tt><ref id=".IMPORT" name=".IMPORT"></tt> will not generate import references for unused symbols). Example: <tscreen><verb> .forceimport needthisone, needthistoo </verb></tscreen> See: <tt><ref id=".IMPORT" name=".IMPORT"></tt> <sect1><tt>.GLOBAL</tt><label id=".GLOBAL"><p> Declare symbols as global. Must be followed by a comma separated list of symbols to declare. Symbols from the list, that are defined somewhere in the source, are exported, all others are imported. Additional <tt><ref id=".IMPORT" name=".IMPORT"></tt> or <tt><ref id=".EXPORT" name=".EXPORT"></tt> commands for the same symbol are allowed. Example: <tscreen><verb> .global foo, bar </verb></tscreen> <sect1><tt>.GLOBALZP</tt><label id=".GLOBALZP"><p> Declare symbols as global. Must be followed by a comma separated list of symbols to declare. Symbols from the list, that are defined somewhere in the source, are exported, all others are imported. Additional <tt><ref id=".IMPORTZP" name=".IMPORTZP"></tt> or <tt><ref id=".EXPORTZP" name=".EXPORTZP"></tt> commands for the same symbol are allowed. The symbols in the list are explicitly marked as zero page symbols. Example: <tscreen><verb> .globalzp foo, bar </verb></tscreen> <sect1><tt>.HIBYTES</tt><label id=".HIBYTES"><p> Define byte sized data by extracting only the high byte (that is, bits 8-15) from each expression. This is equivalent to <tt><ref id=".BYTE" name=".BYTE"></tt> with the operator '>' prepended to each expression in its list. Example: <tscreen><verb> .lobytes $1234, $2345, $3456, $4567 .hibytes $fedc, $edcb, $dcba, $cba9 </verb></tscreen> which is equivalent to <tscreen><verb> .byte $34, $45, $56, $67 .byte $fe, $ed, $dc, $cb </verb></tscreen> Example: <tscreen><verb> .define MyTable TableItem0, TableItem1, TableItem2, TableItem3 TableLookupLo: .lobytes MyTable TableLookupHi: .hibytes MyTable </verb></tscreen> which is equivalent to <tscreen><verb> TableLookupLo: .byte <TableItem0, <TableItem1, <TableItem2, <TableItem3 TableLookupHi: .byte >TableItem0, >TableItem1, >TableItem2, >TableItem3 </verb></tscreen> See also: <tt><ref id=".BYTE" name=".BYTE"></tt>, <tt><ref id=".LOBYTES" name=".LOBYTES"></tt>, <tt><ref id=".BANKBYTES" name=".BANKBYTES"></tt> <sect1><tt>.I16</tt><label id=".I16"><p> Valid only in 65816 mode. Assume the index registers are 16 bit. Note: This command will not emit any code, it will tell the assembler to create 16 bit operands for immediate operands. See also the <tt><ref id=".I8" name=".I8"></tt> and <tt><ref id=".SMART" name=".SMART"></tt> commands. <sect1><tt>.I8</tt><label id=".I8"><p> Valid only in 65816 mode. Assume the index registers are 8 bit. Note: This command will not emit any code, it will tell the assembler to create 8 bit operands for immediate operands. See also the <tt><ref id=".I16" name=".I16"></tt> and <tt><ref id=".SMART" name=".SMART"></tt> commands. <sect1><tt>.IF</tt><label id=".IF"><p> Conditional assembly: Evaluate an expression and switch assembler output on or off depending on the expression. The expression must be a constant expression, that is, all operands must be defined. A expression value of zero evaluates to FALSE, any other value evaluates to TRUE. <sect1><tt>.IFBLANK</tt><label id=".IFBLANK"><p> Conditional assembly: Check if there are any remaining tokens in this line, and evaluate to FALSE if this is the case, and to TRUE otherwise. If the condition is not true, further lines are not assembled until an <tt><ref id=".ELSE" name=".ELSE"></tt>, <tt><ref id=".ELSEIF" name=".ELSEIF"></tt> or <tt><ref id=".ENDIF" name=".ENDIF"></tt> directive. This command is often used to check if a macro parameter was given. Since an empty macro parameter will evaluate to nothing, the condition will evaluate to TRUE if an empty parameter was given. Example: <tscreen><verb> .macro arg1, arg2 .ifblank arg2 lda #arg1 .else lda #arg2 .endif .endmacro </verb></tscreen> See also: <tt><ref id=".BLANK" name=".BLANK"></tt> <sect1><tt>.IFCONST</tt><label id=".IFCONST"><p> Conditional assembly: Evaluate an expression and switch assembler output on or off depending on the constness of the expression. A const expression evaluates to to TRUE, a non const expression (one containing an imported or currently undefined symbol) evaluates to FALSE. See also: <tt><ref id=".CONST" name=".CONST"></tt> <sect1><tt>.IFDEF</tt><label id=".IFDEF"><p> Conditional assembly: Check if a symbol is defined. Must be followed by a symbol name. The condition is true if the given symbol is already defined, and false otherwise. See also: <tt><ref id=".DEFINED" name=".DEFINED"></tt> <sect1><tt>.IFNBLANK</tt><label id=".IFNBLANK"><p> Conditional assembly: Check if there are any remaining tokens in this line, and evaluate to TRUE if this is the case, and to FALSE otherwise. If the condition is not true, further lines are not assembled until an <tt><ref id=".ELSE" name=".ELSE"></tt>, <tt><ref id=".ELSEIF" name=".ELSEIF"></tt> or <tt><ref id=".ENDIF" name=".ENDIF"></tt> directive. This command is often used to check if a macro parameter was given. Since an empty macro parameter will evaluate to nothing, the condition will evaluate to FALSE if an empty parameter was given. Example: <tscreen><verb> .macro arg1, arg2 lda #arg1 .ifnblank arg2 lda #arg2 .endif .endmacro </verb></tscreen> See also: <tt><ref id=".BLANK" name=".BLANK"></tt> <sect1><tt>.IFNDEF</tt><label id=".IFNDEF"><p> Conditional assembly: Check if a symbol is defined. Must be followed by a symbol name. The condition is true if the given symbol is not defined, and false otherwise. See also: <tt><ref id=".DEFINED" name=".DEFINED"></tt> <sect1><tt>.IFNREF</tt><label id=".IFNREF"><p> Conditional assembly: Check if a symbol is referenced. Must be followed by a symbol name. The condition is true if the given symbol was not referenced before, and false otherwise. See also: <tt><ref id=".REFERENCED" name=".REFERENCED"></tt> <sect1><tt>.IFP02</tt><label id=".IFP02"><p> Conditional assembly: Check if the assembler is currently in 6502 mode (see <tt><ref id=".P02" name=".P02"></tt> command). <sect1><tt>.IFP4510</tt><label id=".IFP4510"><p> Conditional assembly: Check if the assembler is currently in 4510 mode (see <tt><ref id=".P4510" name=".P4510"></tt> command). <sect1><tt>.IFP816</tt><label id=".IFP816"><p> Conditional assembly: Check if the assembler is currently in 65816 mode (see <tt><ref id=".P816" name=".P816"></tt> command). <sect1><tt>.IFPC02</tt><label id=".IFPC02"><p> Conditional assembly: Check if the assembler is currently in 65C02 mode (see <tt><ref id=".PC02" name=".PC02"></tt> command). <sect1><tt>.IFPDTV</tt><label id=".IFPDTV"><p> Conditional assembly: Check if the assembler is currently in 6502DTV mode (see <tt><ref id=".PDTV" name=".PDTV"></tt> command). <sect1><tt>.IFPSC02</tt><label id=".IFPSC02"><p> Conditional assembly: Check if the assembler is currently in 65SC02 mode (see <tt><ref id=".PSC02" name=".PSC02"></tt> command). <sect1><tt>.IFREF</tt><label id=".IFREF"><p> Conditional assembly: Check if a symbol is referenced. Must be followed by a symbol name. The condition is true if the given symbol was referenced before, and false otherwise. This command may be used to build subroutine libraries in include files (you may use separate object modules for this purpose too). Example: <tscreen><verb> .ifref ToHex ; If someone used this subroutine ToHex: tay ; Define subroutine lda HexTab,y rts .endif </verb></tscreen> See also: <tt><ref id=".REFERENCED" name=".REFERENCED"></tt>, and <tt><ref id=".REFERTO" name=".REFERTO"></tt> <sect1><tt>.IMPORT</tt><label id=".IMPORT"><p> Import a symbol from another module. The command is followed by a comma separated list of symbols to import, with each one optionally followed by an address specification. Example: <tscreen><verb> .import foo .import bar: zeropage </verb></tscreen> See: <tt><ref id=".IMPORTZP" name=".IMPORTZP"></tt> <sect1><tt>.IMPORTZP</tt><label id=".IMPORTZP"><p> Import a symbol from another module. The command is followed by a comma separated list of symbols to import. The symbols are explicitly imported as zero page symbols (that is, symbols with values in byte range). Example: <tscreen><verb> .importzp foo, bar </verb></tscreen> See: <tt><ref id=".IMPORT" name=".IMPORT"></tt> <sect1><tt>.INCBIN</tt><label id=".INCBIN"><p> Include a file as binary data. The command expects a string argument that is the name of a file to include literally in the current segment. In addition to that, a start offset and a size value may be specified, separated by commas. If no size is specified, all of the file from the start offset to end-of-file is used. If no start position is specified either, zero is assumed (which means that the whole file is inserted). Example: <tscreen><verb> ; Include whole file .incbin "sprites.dat" ; Include file starting at offset 256 .incbin "music.dat", $100 ; Read 100 bytes starting at offset 200 .incbin "graphics.dat", 200, 100 </verb></tscreen> <sect1><tt>.INCLUDE</tt><label id=".INCLUDE"><p> Include another file. Include files may be nested up to a depth of 16. Example: <tscreen><verb> .include "subs.inc" </verb></tscreen> <sect1><tt>.INTERRUPTOR</tt><label id=".INTERRUPTOR"><p> Export a symbol and mark it as an interruptor. This may be used together with the linker to build a table of interruptor subroutines that are called in an interrupt. Note: The linker has a feature to build a table of marked routines, but it is your code that must call these routines, so just declaring a symbol as interruptor does nothing by itself. An interruptor is always exported as an absolute (16 bit) symbol. You don't need to use an additional <tt/.export/ statement, this is implied by <tt/.interruptor/. It may have an optional priority that is separated by a comma. Higher numeric values mean a higher priority. If no priority is given, the default priority of 7 is used. Be careful when assigning priorities to your own module constructors so they won't interfere with the ones in the cc65 library. Example: <tscreen><verb> .interruptor IrqHandler .interruptor Handler, 16 </verb></tscreen> See the <tt><ref id=".CONDES" name=".CONDES"></tt> command and the separate section <ref id="condes" name="Module constructors/destructors"> explaining the feature in more detail. <sect1><tt>.LIST</tt><label id=".LIST"><p> Enable output to the listing. The command can be followed by a boolean switch ("on", "off", "+" or "-") and will enable or disable listing output. The option has no effect if the listing is not enabled by the command line switch -l. If -l is used, an internal counter is set to 1. Lines are output to the listing file, if the counter is greater than zero, and suppressed if the counter is zero. Each use of <tt/.LIST/ will increment or decrement the counter. Example: <tscreen><verb> .list on ; Enable listing output </verb></tscreen> <sect1><tt>.LISTBYTES</tt><label id=".LISTBYTES"><p> Set, how many bytes are shown in the listing for one source line. The default is 12, so the listing will show only the first 12 bytes for any source line that generates more than 12 bytes of code or data. The directive needs an argument, which is either "unlimited", or an integer constant in the range 4..255. Examples: <tscreen><verb> .listbytes unlimited ; List all bytes .listbytes 12 ; List the first 12 bytes .incbin "data.bin" ; Include large binary file </verb></tscreen> <sect1><tt>.LITERAL</tt><label id=".LITERAL"><p> Define byte sized data. Must be followed by a sequence of (byte ranged) expressions or strings. Strings will disregard the current character mapping definition and will be interpreted literally. Example: <tscreen><verb> .literal "Hello " .literal "world", $0D, $00 </verb></tscreen> See: <tt><ref id=".ASCIIZ" name=".ASCIIZ"></tt>,<tt><ref id=".BYTE" name=".BYTE"></tt> <sect1><tt>.LOBYTES</tt><label id=".LOBYTES"><p> Define byte sized data by extracting only the low byte (that is, bits 0-7) from each expression. This is equivalent to <tt><ref id=".BYTE" name=".BYTE"></tt> with the operator '<' prepended to each expression in its list. Example: <tscreen><verb> .lobytes $1234, $2345, $3456, $4567 .hibytes $fedc, $edcb, $dcba, $cba9 </verb></tscreen> which is equivalent to <tscreen><verb> .byte $34, $45, $56, $67 .byte $fe, $ed, $dc, $cb </verb></tscreen> Example: <tscreen><verb> .define MyTable TableItem0, TableItem1, TableItem2, TableItem3 TableLookupLo: .lobytes MyTable TableLookupHi: .hibytes MyTable </verb></tscreen> which is equivalent to <tscreen><verb> TableLookupLo: .byte <TableItem0, <TableItem1, <TableItem2, <TableItem3 TableLookupHi: .byte >TableItem0, >TableItem1, >TableItem2, >TableItem3 </verb></tscreen> See also: <tt><ref id=".BYTE" name=".BYTE"></tt>, <tt><ref id=".HIBYTES" name=".HIBYTES"></tt>, <tt><ref id=".BANKBYTES" name=".BANKBYTES"></tt> <sect1><tt>.LOCAL</tt><label id=".LOCAL"><p> This command may only be used inside a macro definition. It declares a list of identifiers as local to the macro expansion. A problem when using macros are labels: Since they don't change their name, you get a "duplicate symbol" error if the macro is expanded the second time. Labels declared with <tt><ref id=".LOCAL" name=".LOCAL"></tt> have their name mapped to an internal unique name (<tt/___ABCD__/) with each macro invocation. Some other assemblers start a new lexical block inside a macro expansion. This has some drawbacks however, since that will not allow <em/any/ symbol to be visible outside a macro, a feature that is sometimes useful. The <tt><ref id=".LOCAL" name=".LOCAL"></tt> command is in my eyes a better way to address the problem. You get an error when using <tt><ref id=".LOCAL" name=".LOCAL"></tt> outside a macro. <sect1><tt>.LOCALCHAR</tt><label id=".LOCALCHAR"><p> Defines the character that start "cheap" local labels. You may use one of '@' and '?' as start character. The default is '@'. Cheap local labels are labels that are visible only between two non cheap labels. This way you can reuse identifiers like "<tt/loop/" without using explicit lexical nesting. Example: <tscreen><verb> .localchar '?' Clear: lda #$00 ; Global label ?Loop: sta Mem,y ; Local label dey bne ?Loop ; Ok rts Sub: ... ; New global label bne ?Loop ; ERROR: Unknown identifier! </verb></tscreen> <sect1><tt>.MACPACK</tt><label id=".MACPACK"><p> Insert a predefined macro package. The command is followed by an identifier specifying the macro package to insert. Available macro packages are: <tscreen><verb> atari Defines the scrcode macro. cbm Defines the scrcode macro. cpu Defines constants for the .CPU variable. generic Defines generic macros like add, sub, and blt. longbranch Defines conditional long-jump macros. </verb></tscreen> Including a macro package twice, or including a macro package that redefines already existing macros will lead to an error. Example: <tscreen><verb> .macpack longbranch ; Include macro package cmp #$20 ; Set condition codes jne Label ; Jump long on condition </verb></tscreen> Macro packages are explained in more detail in section <ref id="macropackages" name="Macro packages">. <sect1><tt>.MAC, .MACRO</tt><label id=".MACRO"><p> Start a classic macro definition. The command is followed by an identifier (the macro name) and optionally by a comma separated list of identifiers that are macro parameters. A macro definition is terminated by <tt><ref id=".ENDMACRO" name=".ENDMACRO"></tt>. Example: <tscreen><verb> .macro ldax arg ; Define macro ldax lda arg ldx arg+1 </verb></tscreen> See: <tt><ref id=".DELMACRO" name=".DELMACRO"></tt>, <tt><ref id=".ENDMACRO" name=".ENDMACRO"></tt>, <tt><ref id=".EXITMACRO" name=".EXITMACRO"></tt> See also section <ref id="macros" name="Macros">. <sect1><tt>.ORG</tt><label id=".ORG"><p> Start a section of absolute code. The command is followed by a constant expression that gives the new PC counter location for which the code is assembled. Use <tt><ref id=".RELOC" name=".RELOC"></tt> to switch back to relocatable code. By default, absolute/relocatable mode is global (valid even when switching segments). Using <tt>.FEATURE <ref id="org_per_seg" name="org_per_seg"></tt> it can be made segment local. Please note that you <em/do not need/ <tt/.ORG/ in most cases. Placing code at a specific address is the job of the linker, not the assembler, so there is usually no reason to assemble code to a specific address. Example: <tscreen><verb> .org $7FF ; Emit code starting at $7FF </verb></tscreen> <sect1><tt>.OUT</tt><label id=".OUT"><p> Output a string to the console without producing an error. This command is similar to <tt/.ERROR/, however, it does not force an assembler error that prevents the creation of an object file. Example: <tscreen><verb> .out "This code was written by the codebuster(tm)" </verb></tscreen> See also: <tt><ref id=".ERROR" name=".ERROR"></tt>, <tt><ref id=".FATAL" name=".FATAL"></tt>, <tt><ref id=".WARNING" name=".WARNING"></tt> <sect1><tt>.P02</tt><label id=".P02"><p> Enable the 6502 instruction set, disable 65SC02, 65C02 and 65816 instructions. This is the default if not overridden by the <tt><ref id="option--cpu" name="--cpu"></tt> command line option. See: <tt><ref id=".PC02" name=".PC02"></tt>, <tt><ref id=".PSC02" name=".PSC02"></tt>, <tt><ref id=".P816" name=".P816"></tt> and <tt><ref id=".P4510" name=".P4510"></tt> <sect1><tt>.P4510</tt><label id=".P4510"><p> Enable the 4510 instruction set. This is a superset of the 65C02 and 6502 instruction sets. See: <tt><ref id=".P02" name=".P02"></tt>, <tt><ref id=".PSC02" name=".PSC02"></tt>, <tt><ref id=".PC02" name=".PC02"></tt> and <tt><ref id=".P816" name=".P816"></tt> <sect1><tt>.P816</tt><label id=".P816"><p> Enable the 65816 instruction set. This is a superset of the 65SC02 and 6502 instruction sets. See: <tt><ref id=".P02" name=".P02"></tt>, <tt><ref id=".PSC02" name=".PSC02"></tt>, <tt><ref id=".PC02" name=".PC02"></tt> and <tt><ref id=".P4510" name=".P4510"></tt> <sect1><tt>.PAGELEN, .PAGELENGTH</tt><label id=".PAGELENGTH"><p> Set the page length for the listing. Must be followed by an integer constant. The value may be "unlimited", or in the range 32 to 127. The statement has no effect if no listing is generated. The default value is -1 (unlimited) but may be overridden by the <tt/--pagelength/ command line option. Beware: Since ca65 is a one pass assembler, the listing is generated after assembly is complete, you cannot use multiple line lengths with one source. Instead, the value set with the last <tt/.PAGELENGTH/ is used. Examples: <tscreen><verb> .pagelength 66 ; Use 66 lines per listing page .pagelength unlimited ; Unlimited page length </verb></tscreen> <sect1><tt>.PC02</tt><label id=".PC02"><p> Enable the 65C02 instructions set. This instruction set includes all 6502 and 65SC02 instructions. See: <tt><ref id=".P02" name=".P02"></tt>, <tt><ref id=".PSC02" name=".PSC02"></tt>, <tt><ref id=".P816" name=".P816"></tt> and <tt><ref id=".P4510" name=".P4510"></tt> <sect1><tt>.PDTV</tt><label id=".PDTV"><p> Enable the 6502DTV instruction set. This is a superset of the 6502 instruction set. See: <tt><ref id=".P02" name=".P02"></tt> <sect1><tt>.POPCHARMAP</tt><label id=".POPCHARMAP"><p> Pop the last character mapping from the stack, and activate it. This command will switch back to the character mapping that was last pushed onto the character mapping stack using the <tt><ref id=".PUSHCHARMAP" name=".PUSHCHARMAP"></tt> command, and remove this entry from the stack. The assembler will print an error message if the mappting stack is empty when this command is issued. See: <tt><ref id=".CHARMAP" name=".CHARMAP"></tt>, <tt><ref id=".PUSHCHARMAP" name=".PUSHCHARMAP"></tt> <sect1><tt>.POPCPU</tt><label id=".POPCPU"><p> Pop the last CPU setting from the stack, and activate it. This command will switch back to the CPU that was last pushed onto the CPU stack using the <tt><ref id=".PUSHCPU" name=".PUSHCPU"></tt> command, and remove this entry from the stack. The assembler will print an error message if the CPU stack is empty when this command is issued. See: <tt><ref id=".CPU" name=".CPU"></tt>, <tt><ref id=".PUSHCPU" name=".PUSHCPU"></tt>, <tt><ref id=".SETCPU" name=".SETCPU"></tt> <sect1><tt>.POPSEG</tt><label id=".POPSEG"><p> Pop the last pushed segment from the stack, and set it. This command will switch back to the segment that was last pushed onto the segment stack using the <tt><ref id=".PUSHSEG" name=".PUSHSEG"></tt> command, and remove this entry from the stack. The assembler will print an error message if the segment stack is empty when this command is issued. See: <tt><ref id=".PUSHSEG" name=".PUSHSEG"></tt> <sect1><tt>.PROC</tt><label id=".PROC"><p> Start a nested lexical level with the given name and adds a symbol with this name to the enclosing scope. All new symbols from now on are in the local lexical level and are accessible from outside only via <ref id="scopesyntax" name="explicit scope specification">. Symbols defined outside this local level may be accessed as long as their names are not used for new symbols inside the level. Symbols names in other lexical levels do not clash, so you may use the same names for identifiers. The lexical level ends when the <tt><ref id=".ENDPROC" name=".ENDPROC"></tt> command is read. Lexical levels may be nested up to a depth of 16 (this is an artificial limit to protect against errors in the source). Note: Macro names are always in the global level and in a separate name space. There is no special reason for this, it's just that I've never had any need for local macro definitions. Example: <tscreen><verb> .proc Clear ; Define Clear subroutine, start new level lda #$00 L1: sta Mem,y ; L1 is local and does not cause a ; duplicate symbol error if used in other ; places dey bne L1 ; Reference local symbol rts .endproc ; Leave lexical level </verb></tscreen> See: <tt/<ref id=".ENDPROC" name=".ENDPROC">/ and <tt/<ref id=".SCOPE" name=".SCOPE">/ <sect1><tt>.PSC02</tt><label id=".PSC02"><p> Enable the 65SC02 instructions set. This instruction set includes all 6502 instructions. See: <tt><ref id=".P02" name=".P02"></tt>, <tt><ref id=".PC02" name=".PC02"></tt>, <tt><ref id=".P816" name=".P816"></tt> and <tt><ref id=".P4510" name=".P4510"></tt> <sect1><tt>.PUSHCHARMAP</tt><label id=".PUSHCHARMAP"><p> Push the currently active character mapping onto a stack. The stack has a size of 16 entries. <tt/.PUSHCHARMAP/ allows together with <tt><ref id=".POPCHARMAP" name=".POPCHARMAP"></tt> to switch to another character mapping and to restore the old character mapping later, without knowledge of the current mapping. The assembler will print an error message if the character mapping stack is already full, when this command is issued. See: <tt><ref id=".CHARMAP" name=".CHARMAP"></tt>, <tt><ref id=".POPCHARMAP" name=".POPCHARMAP"></tt> <sect1><tt>.PUSHCPU</tt><label id=".PUSHCPU"><p> Push the currently active CPU onto a stack. The stack has a size of 8 entries. <tt/.PUSHCPU/ allows together with <tt><ref id=".POPCPU" name=".POPCPU"></tt> to switch to another CPU and to restore the old CPU later, without knowledge of the current CPU setting. The assembler will print an error message if the CPU stack is already full, when this command is issued. See: <tt><ref id=".CPU" name=".CPU"></tt>, <tt><ref id=".POPCPU" name=".POPCPU"></tt>, <tt><ref id=".SETCPU" name=".SETCPU"></tt> <sect1><tt>.PUSHSEG</tt><label id=".PUSHSEG"><p> Push the currently active segment onto a stack. The entries on the stack include the name of the segment and the segment type. The stack has a size of 16 entries. <tt/.PUSHSEG/ allows together with <tt><ref id=".POPSEG" name=".POPSEG"></tt> to switch to another segment and to restore the old segment later, without even knowing the name and type of the current segment. The assembler will print an error message if the segment stack is already full, when this command is issued. See: <tt><ref id=".POPSEG" name=".POPSEG"></tt> <sect1><tt>.REFERTO, .REFTO</tt><label id=".REFERTO"><p> Mark a symbol as referenced. It is useful in combination with the <tt><ref id=".IFREF" name=".IFREF"></tt> command. A subroutine with two entry points can be created. When the first entry point is called, it sets some default value as an argument, and falls through into the second entry point. <tt>.REFERTO</tt> helps to ensure that the second part is included into binary when only the first entry point is actually used from the code. Example: <tscreen><verb> .ifref NegateValue ; If this subroutine is used NegateValue: ; Define it lda #0 sec sbc Value .ifref ResetValue ; If the ResetValue is also used jmp SetValue ; Jump over it .else .refto SetValue ; Ensure that SetValue will be included .endif .endif .ifref ResetValue ; If this subroutine is used ResetValue: ; Define it lda #0 ; Set a default value .refto SetValue ; Ensure that SetValue will be included .endif .ifref SetValue ; If this or previous subroutine is used SetValue: sta Value rts .endif </verb></tscreen> <sect1><tt>.RELOC</tt><label id=".RELOC"><p> Switch back to relocatable mode. See the <tt><ref id=".ORG" name=".ORG"></tt> command. <sect1><tt>.REPEAT</tt><label id=".REPEAT"><p> Repeat all commands between <tt/.REPEAT/ and <tt><ref id=".ENDREPEAT" name=".ENDREPEAT"></tt> constant number of times. The command is followed by a constant expression that tells how many times the commands in the body should get repeated. Optionally, a comma and an identifier may be specified. If this identifier is found in the body of the repeat statement, it is replaced by the current repeat count (starting with zero for the first time the body is repeated). <tt/.REPEAT/ statements may be nested. If you use the same repeat count identifier for a nested <tt/.REPEAT/ statement, the one from the inner level will be used, not the one from the outer level. Example: The following macro will emit a string that is "encrypted" in that all characters of the string are XORed by the value $55. <tscreen><verb> .macro Crypt Arg .repeat .strlen(Arg), I .byte .strat(Arg, I) ^ $55 .endrep .endmacro </verb></tscreen> See: <tt><ref id=".ENDREPEAT" name=".ENDREPEAT"></tt> <sect1><tt>.RES</tt><label id=".RES"><p> Reserve storage. The command is followed by one or two constant expressions. The first one is mandatory and defines, how many bytes of storage should be defined. The second, optional expression must by a constant byte value that will be used as value of the data. If there is no fill value given, the linker will use the value defined in the linker configuration file (default: zero). Example: <tscreen><verb> ; Reserve 12 bytes of memory with value $AA .res 12, $AA </verb></tscreen> <sect1><tt>.RODATA</tt><label id=".RODATA"><p> Switch to the RODATA segment. The name of the RODATA segment is always "RODATA", so this is a shortcut for <tscreen><verb> .segment "RODATA" </verb></tscreen> The RODATA segment is a segment that is used by the compiler for readonly data like string constants. See also the <tt><ref id=".SEGMENT" name=".SEGMENT"></tt> command. <sect1><tt>.SCOPE</tt><label id=".SCOPE"><p> Start a nested lexical level with the given name. All new symbols from now on are in the local lexical level and are accessible from outside only via <ref id="scopesyntax" name="explicit scope specification">. Symbols defined outside this local level may be accessed as long as their names are not used for new symbols inside the level. Symbols names in other lexical levels do not clash, so you may use the same names for identifiers. The lexical level ends when the <tt><ref id=".ENDSCOPE" name=".ENDSCOPE"></tt> command is read. Lexical levels may be nested up to a depth of 16 (this is an artificial limit to protect against errors in the source). Note: Macro names are always in the global level and in a separate name space. There is no special reason for this, it's just that I've never had any need for local macro definitions. Example: <tscreen><verb> .scope Error ; Start new scope named Error None = 0 ; No error File = 1 ; File error Parse = 2 ; Parse error .endscope ; Close lexical level ... lda #Error::File ; Use symbol from scope Error </verb></tscreen> See: <tt/<ref id=".ENDSCOPE" name=".ENDSCOPE">/ and <tt/<ref id=".PROC" name=".PROC">/ <sect1><tt>.SEGMENT</tt><label id=".SEGMENT"><p> Switch to another segment. Code and data is always emitted into a segment, that is, a named section of data. The default segment is "CODE". There may be up to 254 different segments per object file (and up to 65534 per executable). There are shortcut commands for the most common segments ("ZEROPAGE", "CODE", "RODATA", "DATA", and "BSS"). The command is followed by a string containing the segment name (there are some constraints for the name - as a rule of thumb use only those segment names that would also be valid identifiers). There may also be an optional address size separated by a colon. See the section covering <tt/<ref id="address-sizes" name="address sizes">/ for more information. The default address size for a segment depends on the memory model specified on the command line. The default is "absolute", which means that you don't have to use an address size modifier in most cases. "absolute" means that the is a segment with 16 bit (absolute) addressing. That is, the segment will reside somewhere in core memory outside the zero page. "zeropage" (8 bit) means that the segment will be placed in the zero page and direct (short) addressing is possible for data in this segment. Beware: Only labels in a segment with the zeropage attribute are marked as reachable by short addressing. The '*' (PC counter) operator will work as in other segments and will create absolute variable values. Please note that a segment cannot have two different address sizes. A segment specified as zeropage cannot be declared as being absolute later. Examples: <tscreen><verb> .segment "ROM2" ; Switch to ROM2 segment .segment "ZP2": zeropage ; New direct segment .segment "ZP2" ; Ok, will use last attribute .segment "ZP2": absolute ; Error, redecl mismatch </verb></tscreen> See: <tt><ref id=".BSS" name=".BSS"></tt>, <tt><ref id=".CODE" name=".CODE"></tt>, <tt><ref id=".DATA" name=".DATA"></tt>, <tt><ref id=".RODATA" name=".RODATA"></tt>, and <tt><ref id=".ZEROPAGE" name=".ZEROPAGE"></tt> <sect1><tt>.SET</tt><label id=".SET"><p> <tt/.SET/ is used to assign a value to a variable. See <ref id="variables" name="Numeric variables"> for a full description. <sect1><tt>.SETCPU</tt><label id=".SETCPU"><p> Switch the CPU instruction set. The command is followed by a string that specifies the CPU. Possible values are those that can also be supplied to the <tt><ref id="option--cpu" name="--cpu"></tt> command line option, namely: 6502, 6502X, 6502DTV, 65SC02, 65C02, 65816, 4510 and HuC6280. See: <tt><ref id=".CPU" name=".CPU"></tt>, <tt><ref id=".IFP02" name=".IFP02"></tt>, <tt><ref id=".IFPDTV" name=".IFPDTV"></tt>, <tt><ref id=".IFP816" name=".IFP816"></tt>, <tt><ref id=".IFPC02" name=".IFPC02"></tt>, <tt><ref id=".IFPSC02" name=".IFPSC02"></tt>, <tt><ref id=".P02" name=".P02"></tt>, <tt><ref id=".P816" name=".P816"></tt>, <tt><ref id=".P4510" name=".P4510"></tt>, <tt><ref id=".PC02" name=".PC02"></tt>, <tt><ref id=".PSC02" name=".PSC02"></tt> <sect1><tt>.SMART</tt><label id=".SMART"><p> Switch on or off smart mode. The command can be followed by a '+' or '-' character to switch the option on or off respectively. The default is off (that is, the assembler doesn't try to be smart), but this default may be changed by the -s switch on the command line. In smart mode the assembler will do the following: <itemize> <item>Track usage of the <tt/REP/ and <tt/SEP/ instructions in 65816 mode and update the operand sizes accordingly. If the operand of such an instruction cannot be evaluated by the assembler (for example, because the operand is an imported symbol), a warning is issued. Beware: Since the assembler cannot trace the execution flow this may lead to false results in some cases. If in doubt, use the <tt/.Inn/ and <tt/.Ann/ instructions to tell the assembler about the current settings. <item>In 65816 mode, if the <tt><ref id="long_jsr_jmp_rts" name="long_jsr_jmp_rts"></tt> feature is enabled, smart mode will replace a <tt/RTS/ instruction by <tt/RTL/ if it is used within a procedure declared as <tt/far/, or if the procedure has no explicit address specification, but it is <tt/far/ because of the memory model used. </itemize> Example: <tscreen><verb> .smart ; Be smart .smart - ; Stop being smart </verb></tscreen> See: <tt><ref id=".A16" name=".A16"></tt>, <tt><ref id=".A8" name=".A8"></tt>, <tt><ref id=".I16" name=".I16"></tt>, <tt><ref id=".I8" name=".I8"></tt> <sect1><tt>.STRUCT</tt><label id=".STRUCT"><p> Starts a struct definition. Structs are covered in a separate section named <ref id="structs" name=""Structs and unions"">. See also: <tt><ref id=".ENDSTRUCT" name=".ENDSTRUCT"></tt>, <tt><ref id=".ENDUNION" name=".ENDUNION"></tt>, <tt><ref id=".UNION" name=".UNION"></tt> <sect1><tt>.TAG</tt><label id=".TAG"><p> Allocate space for a struct or union. This is equivalent to <tt><ref id=".RES" name=".RES"></tt> with the <tt><ref id=".SIZEOF" name=".SIZEOF"></tt> of a struct. Example: <tscreen><verb> .struct Point xcoord .word ycoord .word .endstruct .bss .tag Point ; Allocate 4 bytes </verb></tscreen> See: <ref id="structs" name=""Structs and unions""> <sect1><tt>.UNDEF, .UNDEFINE</tt><label id=".UNDEFINE"><p> Delete a define style macro definition. The command is followed by an identifier which specifies the name of the macro to delete. Macro replacement is switched of when reading the token following the command (otherwise the macro name would be replaced by its replacement list). See also the <tt><ref id=".DEFINE" name=".DEFINE"></tt> command and section <ref id="macros" name="Macros">. <sect1><tt>.UNION</tt><label id=".UNION"><p> Starts a union definition. Unions are covered in a separate section named <ref id="structs" name=""Structs and unions"">. See also: <tt><ref id=".ENDSTRUCT" name=".ENDSTRUCT"></tt>, <tt><ref id=".ENDUNION" name=".ENDUNION"></tt>, <tt><ref id=".STRUCT" name=".STRUCT"></tt> <sect1><tt>.WARNING</tt><label id=".WARNING"><p> Force an assembly warning. The assembler will output a warning message preceded by "User warning". This warning will always be output, even if other warnings are disabled with the <tt><ref id="option-W" name="-W0"></tt> command line option. This command may be used to output possible problems when assembling the source file. Example: <tscreen><verb> .macro jne target .local L1 .ifndef target .warning "Forward jump in jne, cannot optimize!" beq L1 jmp target L1: .else ... .endif .endmacro </verb></tscreen> See also: <tt><ref id=".ERROR" name=".ERROR"></tt>, <tt><ref id=".FATAL" name=".FATAL"></tt>, <tt><ref id=".OUT" name=".OUT"></tt> <sect1><tt>.WORD</tt><label id=".WORD"><p> Define word sized data. Must be followed by a sequence of (word ranged, but not necessarily constant) expressions. Example: <tscreen><verb> .word $0D00, $AF13, _Clear </verb></tscreen> <sect1><tt>.ZEROPAGE</tt><label id=".ZEROPAGE"><p> Switch to the ZEROPAGE segment and mark it as direct (zeropage) segment. The name of the ZEROPAGE segment is always "ZEROPAGE", so this is a shortcut for <tscreen><verb> .segment "ZEROPAGE": zeropage </verb></tscreen> Because of the "zeropage" attribute, labels declared in this segment are addressed using direct addressing mode if possible. You <em/must/ instruct the linker to place this segment somewhere in the address range 0..$FF otherwise you will get errors. See: <tt><ref id=".SEGMENT" name=".SEGMENT"></tt> <sect>Macros<label id="macros"><p> <sect1>Introduction<p> Macros may be thought of as "parametrized super instructions". Macros are sequences of tokens that have a name. If that name is used in the source file, the macro is "expanded", that is, it is replaced by the tokens that were specified when the macro was defined. <sect1>Macros without parameters<p> In its simplest form, a macro does not have parameters. Here's an example: <tscreen><verb> .macro asr ; Arithmetic shift right cmp #$80 ; Put bit 7 into carry ror ; Rotate right with carry .endmacro </verb></tscreen> The macro above consists of two real instructions, that are inserted into the code, whenever the macro is expanded. Macro expansion is simply done by using the name, like this: <tscreen><verb> lda $2010 asr sta $2010 </verb></tscreen> <sect1>Parametrized macros<p> When using macro parameters, macros can be even more useful: <tscreen><verb> .macro inc16 addr clc lda addr adc #<$0001 sta addr lda addr+1 adc #>$0001 sta addr+1 .endmacro </verb></tscreen> When calling the macro, you may give a parameter, and each occurrence of the name "addr" in the macro definition will be replaced by the given parameter. So <tscreen><verb> inc16 $1000 </verb></tscreen> will be expanded to <tscreen><verb> clc lda $1000 adc #<$0001 sta $1000 lda $1000+1 adc #>$0001 sta $1000+1 </verb></tscreen> A macro may have more than one parameter, in this case, the parameters are separated by commas. You are free to give less parameters than the macro actually takes in the definition. You may also leave intermediate parameters empty. Empty parameters are replaced by empty space (that is, they are removed when the macro is expanded). If you have a look at our macro definition above, you will see, that replacing the "addr" parameter by nothing will lead to wrong code in most lines. The names "a", "x" and "y" should be avoided for macro parameters, as these will usually conflict with the 6502 registers. For writing macros with a variable parameter list, control commands are available: <tt><ref id=".IFBLANK" name=".IFBLANK"></tt> tests the rest of the line and returns true, if there are any tokens on the remainder of the line. Since empty parameters are replaced by nothing, this may be used to test if a given parameter is empty. <tt><ref id=".IFNBLANK" name=".IFNBLANK"></tt> tests the opposite. Look at this example: <tscreen><verb> .macro ldaxy i, j, k .ifnblank i lda #i .endif .ifnblank j ldx #j .endif .ifnblank k ldy #k .endif .endmacro </verb></tscreen> That macro may be called as follows: <tscreen><verb> ldaxy 1, 2, 3 ; Load all three registers ldaxy 1, , 3 ; Load only a and y ldaxy , , 3 ; Load y only </verb></tscreen> There's another helper command for determining which macro parameters are valid: <tt><ref id=".PARAMCOUNT" name=".PARAMCOUNT"></tt>. That command is replaced by the parameter count given, <em/including/ explicitly empty parameters: <tscreen><verb> ldaxy 1 ; .PARAMCOUNT = 1 ldaxy 1,,3 ; .PARAMCOUNT = 3 ldaxy 1,2 ; .PARAMCOUNT = 2 ldaxy 1, ; .PARAMCOUNT = 2 ldaxy 1,2,3 ; .PARAMCOUNT = 3 </verb></tscreen> Macro parameters may optionally be enclosed into curly braces. This allows the inclusion of tokens that would otherwise terminate the parameter (the comma in case of a macro parameter). <tscreen><verb> .macro foo arg1, arg2 ... .endmacro foo ($00,x) ; Two parameters passed foo {($00,x)} ; One parameter passed </verb></tscreen> In the first case, the macro is called with two parameters: '<tt/($00/' and '<tt/x)/'. The comma is not passed to the macro, because it is part of the calling sequence, not the parameters. In the second case, '<tt/($00,x)/' is passed to the macro; this time, including the comma. <sect1>Detecting parameter types<p> Sometimes it is nice to write a macro that acts differently depending on the type of the argument supplied. An example would be a macro that loads a 16 bit value from either an immediate operand, or from memory. The <tt/<ref id=".MATCH" name=".MATCH">/ and <tt/<ref id=".XMATCH" name=".XMATCH">/ functions will allow you to do exactly this: <tscreen><verb> .macro ldax arg .if (.match (.left (1, {arg}), #)) ; immediate mode lda #<(.right (.tcount ({arg})-1, {arg})) ldx #>(.right (.tcount ({arg})-1, {arg})) .else ; assume absolute or zero page lda arg ldx 1+(arg) .endif .endmacro </verb></tscreen> Using the <tt/<ref id=".MATCH" name=".MATCH">/ function, the macro is able to check if its argument begins with a hash mark. If so, two immediate loads are emitted, Otherwise a load from an absolute zero page memory location is assumed. Please note how the curly braces are used to enclose parameters to pseudo functions handling token lists. This is necessary, because the token lists may include commas or parens, which would be treated by the assembler as end-of-list. The macro can be used as <tscreen><verb> foo: .word $5678 ... ldax #$1234 ; X=$12, A=$34 ... ldax foo ; X=$56, A=$78 </verb></tscreen> <sect1>Recursive macros<p> Macros may be used recursively: <tscreen><verb> .macro push r1, r2, r3 lda r1 pha .ifnblank r2 push r2, r3 .endif .endmacro </verb></tscreen> There's also a special macro command to help with writing recursive macros: <tt><ref id=".EXITMACRO" name=".EXITMACRO"></tt>. That command will stop macro expansion immediately: <tscreen><verb> .macro push r1, r2, r3, r4, r5, r6, r7 .ifblank r1 ; First parameter is empty .exitmacro .else lda r1 pha .endif push r2, r3, r4, r5, r6, r7 .endmacro </verb></tscreen> When expanding that macro, the expansion will push all given parameters until an empty one is encountered. The macro may be called like this: <tscreen><verb> push $20, $21, $32 ; Push 3 ZP locations push $21 ; Push one ZP location </verb></tscreen> <sect1>Local symbols inside macros<p> Now, with recursive macros, <tt><ref id=".IFBLANK" name=".IFBLANK"></tt> and <tt><ref id=".PARAMCOUNT" name=".PARAMCOUNT"></tt>, what else do you need? Have a look at the inc16 macro above. Here is it again: <tscreen><verb> .macro inc16 addr clc lda addr adc #<$0001 sta addr lda addr+1 adc #>$0001 sta addr+1 .endmacro </verb></tscreen> If you have a closer look at the code, you will notice, that it could be written more efficiently, like this: <tscreen><verb> .macro inc16 addr inc addr bne Skip inc addr+1 Skip: .endmacro </verb></tscreen> But imagine what happens, if you use this macro twice? Since the label "Skip" has the same name both times, you get a "duplicate symbol" error. Without a way to circumvent this problem, macros are not as useful, as they could be. One possible solution is the command <tt><ref id=".LOCAL" name=".LOCAL"></tt>. It declares one or more symbols as local to the macro expansion. The names of local variables are replaced by a unique name in each separate macro expansion. So we can solve the problem above by using <tt/.LOCAL/: <tscreen><verb> .macro inc16 addr .local Skip ; Make Skip a local symbol inc addr bne Skip inc addr+1 Skip: ; Not visible outside .endmacro </verb></tscreen> Another solution is of course to start a new lexical block inside the macro that hides any labels: <tscreen><verb> .macro inc16 addr .proc inc addr bne Skip inc addr+1 Skip: .endproc .endmacro </verb></tscreen> <sect1>C style macros<p> Starting with version 2.5 of the assembler, there is a second macro type available: C style macros using the <tt/.DEFINE/ directive. These macros are similar to the classic macro type described above, but behaviour is sometimes different: <itemize> <item> Macros defined with <tt><ref id=".DEFINE" name=".DEFINE"></tt> may not span more than a line. You may use line continuation (see <tt><ref id="line_continuations" name="line_continuations"></tt>) to spread the definition over more than one line for increased readability, but the macro itself may not contain an end-of-line token. <item> Macros defined with <tt><ref id=".DEFINE" name=".DEFINE"></tt> share the name space with classic macros, but they are detected and replaced at the scanner level. While classic macros may be used in every place, where a mnemonic or other directive is allowed, <tt><ref id=".DEFINE" name=".DEFINE"></tt> style macros are allowed anywhere in a line. So they are more versatile in some situations. <item> <tt><ref id=".DEFINE" name=".DEFINE"></tt> style macros may take parameters. While classic macros may have empty parameters, this is not true for <tt><ref id=".DEFINE" name=".DEFINE"></tt> style macros. For this macro type, the number of actual parameters must match exactly the number of formal parameters. To make this possible, formal parameters are enclosed in parentheses when defining the macro. If there are no parameters, the empty parentheses may be omitted. <item> Since <tt><ref id=".DEFINE" name=".DEFINE"></tt> style macros may not contain end-of-line tokens, there are things that cannot be done. They may not contain several processor instructions for example. So, while some things may be done with both macro types, each type has special usages. The types complement each other. <item> Parentheses work differently from C macros. The common practice of wrapping C macros in parentheses may cause unintended problems here, such as accidentally implying an indirect addressing mode. While the definition of a macro requires parentheses around its argument list, when invoked they should not be included. </itemize> Let's look at a few examples to make the advantages and disadvantages clear. To emulate assemblers that use "<tt/EQU/" instead of "<tt/=/" you may use the following <tt/.DEFINE/: <tscreen><verb> .define EQU = foo EQU $1234 ; This is accepted now </verb></tscreen> You may use the directive to define string constants used elsewhere: <tscreen><verb> ; Define the version number .define VERSION "12.3a" ; ... and use it .asciiz VERSION </verb></tscreen> Macros with parameters may also be useful: <tscreen><verb> .define DEBUG(message) .out message DEBUG "Assembling include file #3" </verb></tscreen> Note that, while formal parameters have to be placed in parentheses, the actual argument used when invoking the macro should not be. The invoked arguments are separated by commas only; if parentheses are used by accident, they will become part of the replaced token. If you wish to have an expression follow the macro invocation, the last parameter can be enclosed in curly braces {} to indicate the end of that argument. Examples: <tscreen><verb> .define COMBINE(ta,tb,tc) ta+tb*10+tc*100 .word COMBINE 5,6,7 ; 5+6*10+7*100 = 765 .word COMBINE(5,6,7) ; (5+6*10+7)*100 = 7200 ; incorrect use of parentheses .word COMBINE 5,6,7+1 ; 5+6*10+7+1*100 = 172 .word COMBINE 5,6,{7}+1 ; 5+6*10+7*100+1 = 766 ; {} encloses the argument .word COMBINE 5,6-2,7 ; 5+6-2*10+7*100 = 691 .word COMBINE 5,(6-2),7 ; 5+(6-2)*10+7*100 = 745 .word COMBINE 5,6,7+COMBINE 0,1,2 ; 5+6*10+7+0+1*10+2*100*100 = 20082 .word COMBINE 5,6,{7}+COMBINE 0,1,2 ; 5+6*10+7*100+0+1*10+2*100 = 975 </verb></tscreen> With C macros it is common to enclose the results in parentheses to prevent unintended interactions with the text of the arguments, but additional care must be taken in this assembly context where parentheses may alter the meaning of a statement. In particular, indirect addressing modes may be accidentally implied: <tscreen><verb> .define DUO(ta,tb) (ta+(tb*10)) lda DUO(5,4), Y ; LDA (indirect), Y lda 0+DUO(5,4), Y ; LDA absolute indexed, Y </verb></tscreen> <sect1>Characters in macros<p> When using the <ref id="option-t" name="-t"> option, characters are translated into the target character set of the specific machine. However, this happens as late as possible. This means that strings are translated if they are part of a <tt><ref id=".BYTE" name=".BYTE"></tt> or <tt><ref id=".ASCIIZ" name=".ASCIIZ"></tt> command. Characters are translated as soon as they are used as part of an expression. This behaviour is very intuitive outside of macros but may be confusing when doing more complex macros. If you compare characters against numeric values, be sure to take the translation into account. <sect1>Deleting macros<p> Macros can be deleted. This will not work if the macro that should be deleted is currently expanded as in the following non-working example: <tscreen><verb> .macro notworking .delmacro notworking .endmacro notworking ; Will not work </verb></tscreen> The commands to delete classic and define style macros differ. Classic macros can be deleted by use of <tt><ref id=".DELMACRO" name=".DELMACRO"></tt>, while for <tt><ref id=".DEFINE" name=".DEFINE"></tt> style macros, <tt><ref id=".UNDEFINE" name=".UNDEFINE"></tt> must be used. Example: <tscreen><verb> .define value 1 .macro mac .byte 2 .endmacro .byte value ; Emit one byte with value 1 mac ; Emit another byte with value 2 .undefine value .delmacro mac .byte value ; Error: Unknown identifier mac ; Error: Missing ":" </verb></tscreen> A separate command for <tt>.DEFINE</tt> style macros was necessary, because the name of such a macro is replaced by its replacement list on a very low level. To get the actual name, macro replacement has to be switched off when reading the argument to <tt>.UNDEFINE</tt>. This does also mean that the argument to <tt>.UNDEFINE</tt> is not allowed to come from another <tt>.DEFINE</tt>. All this is not necessary for classic macros, so having two different commands increases flexibility. <sect>Macro packages<label id="macropackages"><p> Using the <tt><ref id=".MACPACK" name=".MACPACK"></tt> directive, predefined macro packages may be included with just one command. Available macro packages are: <sect1><tt>.MACPACK generic</tt><p> This macro package defines macros that are useful in almost any program. Currently defined macros are: <tscreen><verb> .macro add Arg ; add without carry clc adc Arg .endmacro .macro sub Arg ; subtract without borrow sec sbc Arg .endmacro .macro bge Arg ; branch on greater-than or equal bcs Arg .endmacro .macro blt Arg ; branch on less-than bcc Arg .endmacro .macro bgt Arg ; branch on greater-than .local L beq L bcs Arg L: .endmacro .macro ble Arg ; branch on less-than or equal beq Arg bcc Arg .endmacro .macro bnz Arg ; branch on not zero bne Arg .endmacro .macro bze Arg ; branch on zero beq Arg .endmacro </verb></tscreen> <sect1><tt>.MACPACK longbranch</tt><p> This macro package defines long conditional jumps. They are named like the short counterpart but with the 'b' replaced by a 'j'. Here is a sample definition for the "<tt/jeq/" macro, the other macros are built using the same scheme: <tscreen><verb> .macro jeq Target .if .def(Target) .and ((*+2)-(Target) <= 127) beq Target .else bne *+5 jmp Target .endif .endmacro </verb></tscreen> All macros expand to a short branch, if the label is already defined (back jump) and is reachable with a short jump. Otherwise the macro expands to a conditional branch with the branch condition inverted, followed by an absolute jump to the actual branch target. The package defines the following macros: <tscreen><verb> jeq, jne, jmi, jpl, jcs, jcc, jvs, jvc </verb></tscreen> <sect1><tt>.MACPACK apple2</tt><p> This macro package defines a macro named <tt/scrcode/. It takes a string as argument and places this string into memory translated into screen codes. <sect1><tt>.MACPACK atari</tt><p> This macro package defines a macro named <tt/scrcode/. It takes a string as argument and places this string into memory translated into screen codes. <sect1><tt>.MACPACK cbm</tt><p> This macro package defines a macro named <tt/scrcode/. It takes a string as argument and places this string into memory translated into screen codes. <sect1><tt>.MACPACK cpu</tt><p> This macro package does not define any macros but constants used to examine the value read from the <tt/<ref id=".CPU" name=".CPU">/ pseudo variable. For each supported CPU a constant similar to <tscreen><verb> CPU_6502 CPU_65SC02 CPU_65C02 CPU_65816 CPU_SWEET16 CPU_HUC6280 CPU_4510 CPU_6502DTV </verb></tscreen> is defined. These constants may be used to determine the exact type of the currently enabled CPU. In addition to that, for each CPU instruction set, another constant is defined: <tscreen><verb> CPU_ISET_6502 CPU_ISET_65SC02 CPU_ISET_65C02 CPU_ISET_65816 CPU_ISET_SWEET16 CPU_ISET_HUC6280 CPU_ISET_4510 CPU_ISET_6502DTV </verb></tscreen> The value read from the <tt/<ref id=".CPU" name=".CPU">/ pseudo variable may be checked with <tt/<ref id="operators" name=".BITAND">/ to determine if the currently enabled CPU supports a specific instruction set. For example the 65C02 supports all instructions of the 65SC02 CPU, so it has the <tt/CPU_ISET_65SC02/ bit set in addition to its native <tt/CPU_ISET_65C02/ bit. Using <tscreen><verb> .if (.cpu .bitand CPU_ISET_65SC02) lda (sp) .else ldy #$00 lda (sp),y .endif </verb></tscreen> it is possible to determine if the <tscreen><verb> lda (sp) </verb></tscreen> instruction is supported, which is the case for the 65SC02, 65C02 and 65816 CPUs (the latter two are upwards compatible to the 65SC02). <sect1><tt>.MACPACK module</tt><p> This macro package defines a macro named <tt/module_header/. It takes an identifier as argument and is used to define the header of a module both in the dynamic and static variant. <sect>Predefined constants<label id="predefined-constants"><p> For better orthogonality, the assembler defines similar symbols as the compiler, depending on the target system selected: <itemize> <item><tt/__APPLE2__/ - Target system is <tt/apple2/ or <tt/apple2enh/ <item><tt/__APPLE2ENH__/ - Target system is <tt/apple2enh/ <item><tt/__ATARI2600__/ - Target system is <tt/atari2600/ <item><tt/__ATARI5200__/ - Target system is <tt/atari5200/ <item><tt/__ATARI7800__/ - Target system is <tt/atari7800/ <item><tt/__ATARI__/ - Target system is <tt/atari/ or <tt/atarixl/ <item><tt/__ATARIXL__/ - Target system is <tt/atarixl/ <item><tt/__ATMOS__/ - Target system is <tt/atmos/ <item><tt/__BBC__/ - Target system is <tt/bbc/ <item><tt/__C128__/ - Target system is <tt/c128/ <item><tt/__C16__/ - Target system is <tt/c16/ or <tt/plus4/ <item><tt/__C64__/ - Target system is <tt/c64/ <item><tt/__CBM__/ - Target is a Commodore or Commodore-alike system <item><tt/__CBM510__/ - Target system is <tt/cbm510/ <item><tt/__CBM610__/ - Target system is <tt/cbm610/ <item><tt/__CX16__/ - Target system is <tt/cx16/ <item><tt/__GEOS__/ - Target is a GEOS system <item><tt/__GEOS_APPLE__/ - Target system is <tt/geos-apple/ <item><tt/__GEOS_CBM__/ - Target system is <tt/geos-cbm/ <item><tt/__LUNIX__/ - Target system is <tt/lunix/ <item><tt/__LYNX__/ - Target system is <tt/lynx/ <item><tt/__NES__/ - Target system is <tt/nes/ <item><tt/__OSIC1P__/ - Target system is <tt/osic1p/ <item><tt/__PET__/ - Target system is <tt/pet/ <item><tt/__PLUS4__/ - Target system is <tt/plus4/ <item><tt/__SIM6502__/ - Target system is <tt/sim6502/ <item><tt/__SIM65C02__/ - Target system is <tt/sim65c02/ <item><tt/__SUPERVISION__/ - Target system is <tt/supervision/ <item><tt/__SYM1__/ - Target system is <tt/sym1/ <item><tt/__VIC20__/ - Target system is <tt/vic20/ </itemize> <sect>Structs and unions<label id="structs"><p> <sect1>Structs and unions Overview<p> Structs and unions are special forms of <ref id="scopes" name="scopes">. They are, to some degree, comparable to their C counterparts. Both have a list of members. Each member allocates storage, and optionally may have a name. Each named member has a constant value equal to the storage offset from the beginning of the structure. In the case of a union, all members are placed at the same offset, typically 0. Each named member also has a storage size which can be accessed with the <tt><ref id=".SIZEOF" name=".SIZEOF"></tt> operator. The struct or union itself also has a <tt/.SIZEOF/ indicating its total storage size. <sect1>Declaration<p> Here is an example for a very simple struct with two members and a total size of 4 bytes: <tscreen><verb> .struct Point xcoord .word ycoord .word .endstruct </verb></tscreen> A union shares the total space between all its members; its size is the same as that of the largest member. The offset of all members relative to the union is zero. <tscreen><verb> .union Entry index .word ptr .addr .endunion </verb></tscreen> A struct or union may not necessarily have a name. If it is anonymous, no local scope is opened; the identifiers used to name the members are placed into the current scope instead. Storage allocators may contain a multiplier. A struct may also contain members and definitions of local structs/unions. Example: <tscreen><verb> .struct Circle .struct Point .word 2 ; Allocate two words .endstruct Radius .word .endstruct </verb></tscreen> In this example the size of the Circle struct is 6 (three words). <sect1>The storage allocator keywords<p> <descrip> <tag/.BYTE, .RES/ Allocates multiples of 1 byte. <tt/.RES/ requires an operand. <tag/.DBYT, .WORD, .ADDR/ Allocates multiples of 2 bytes. <tag/.FARADDR/ Allocates multiples of 3 bytes. <tag/.DWORD/ Allocates multiples of 4 bytes. <tag/.TAG/ Allocates a previously defined struct. <tag/.STRUCT, .UNION/ Begins a nested .struct or .union definition, and allocates it. Note that its member offset values will begin at 0, unless this nested structure is anonymous, in which case they will instead become members of the enclosing scope. </descrip> <sect1>The <tt/.ORG/ keyword<p> The <tt/.ORG/ keyword changes the offset value that is assigned to subsequent member names. It's useful when using a struct to define the names of the registers in an I/O chip. Example: <tscreen><verb> ; 6551 .struct ACIA ; Asynchronous Communications Interface Adapter .org $031C DATA .byte STATUS .byte CMD .byte ; Command register CTRL .byte ; Control register .endstruct lda ACIA::DATA ; Get an RS-232 character </verb></tscreen> <sect1>The <tt/.TAG/ keyword<p> By using the <ref id=".TAG" name=".TAG"> keyword, it is possible to reserve space for an already defined struct or union within another struct: <tscreen><verb> .struct Point xcoord .word ycoord .word .endstruct .struct Circle Origin .tag Point Radius .byte .endstruct </verb></tscreen> Actual space for a struct or union may be allocated by using the <ref id=".TAG" name=".TAG"> directive. <tscreen><verb> C: .tag Circle </verb></tscreen> Members are just offsets from the start of the struct or union. To access a field of a struct, the member offset must be added to the address of the struct variable itself: <tscreen><verb> lda C + Circle::Radius ; Load circle radius lda C + Circle::Origin + Point::ycoord ; Load circle origin.ycoord </verb></tscreen> Nested structures or unions are treated differently depending on whether they are anonymous. If named, a new structure definition is created within the enclosing scope, with its offsets beginning at 0. If anonymous, the members of the new structure are added to the enclosing scope instead, with offsets continuing through that scope. Example: <tscreen><verb> .struct Object id .byte ; Object::id = 0 target .struct Point ; Object::target = 1 xcoord .word ; Object::Point::xcoord = 0 ycoord .word ; Object::Point::ycoord = 2 .endstruct cost .struct ; Object::cost = 5 price .word ; Object::price = 5 tax .word ; Object::tax = 7 .endstruct .struct radius .word ; Object::radius = 9 .endstruct .endstruct O: .tag Object lda O + Object::target + Object::Point::ycoord ; Named struct lda O + Object::tax ; Anonymous lda O + Object::radius ; Anonymous ; Be careful not to use a named nested structure without also adding the ; offset to the nested structure itself. lda O + Object::Point::ycoord ; Incorrect! lda O + Object::target + Object::Point::ycoord ; Correct </verb></tscreen> In this example, the first nested structure is named "Point", and its member offsets begin at 0. On the other hand, the two anonymous structures simply continue to add members to the enclosing "Object" structure. Note that an anonymous structure does not need a member name, since all of its members become part of the enclosing structure. The "cost" member in the example is redundantly the same offset as its first member "price". <sect1>Limitations<p> Structs and unions currently are implemented as nested symbol tables (in fact, they were a by-product of the improved scoping rules). Currently, the assembler has no idea of types. That means that the <ref id=".TAG" name=".TAG"> keyword only will allocate space. You won't be able to initialize variables declared with <ref id=".TAG" name=".TAG">; and, adding an embedded structure to another structure with <ref id=".TAG" name=".TAG"> will not make that added structure accessible by using the '::' operator. <sect>Module constructors/destructors<label id="condes"><p> <em>Note:</em> This section applies mostly to C programs, so the explanation below uses examples from the C libraries. However, the feature may also be useful for assembler programs. <sect1>Module constructors/destructors Overview<p> Using the <tt><ref id=".CONSTRUCTOR" name=".CONSTRUCTOR"></tt>, <tt><ref id=".DESTRUCTOR" name=".DESTRUCTOR"></tt> and <tt><ref id=".INTERRUPTOR" name=".INTERRUPTOR"></tt> keywords it is possible to export functions in a special way. The linker is able to generate tables with all functions of a specific type. Such a table will <em>only</em> include symbols from object files that are linked into a specific executable. This may be used to add initialization and cleanup code for library modules, or a table of interrupt handler functions. The C heap functions are an example where module initialization code is used. All heap functions (<tt>malloc</tt>, <tt>free</tt>, ...) work with a few variables that contain the start and the end of the heap, pointers to the free list and so on. Since the end of the heap depends on the size and start of the stack, it must be initialized at runtime. However, initializing these variables for programs that do not use the heap are a waste of time and memory. So the central module defines a function that contains initialization code and exports this function using the <tt/.CONSTRUCTOR/ statement. If (and only if) this module is added to an executable by the linker, the initialization function will be placed into the table of constructors by the linker. The C startup code will call all constructors before <tt/main/ and all destructors after <tt/main/, so without any further work, the heap initialization code is called once the module is linked in. While it would be possible to add explicit calls to initialization functions in the startup code, the new approach has several advantages: <enum> <item> If a module is not included, the initialization code is not linked in and not called. So you don't pay for things you don't need. <item> Adding another library that needs initialization does not mean that the startup code has to be changed. Before we had module constructors and destructors, the startup code for all systems had to be adjusted to call the new initialization code. <item> The feature saves memory: Each additional initialization function needs just two bytes in the table (a pointer to the function). </enum> <sect1>Calling order<p> The symbols are sorted in increasing priority order by the linker when using one of the builtin linker configurations, so the functions with lower priorities come first and are followed by those with higher priorities. The C library runtime subroutine that walks over the function tables calls the functions starting from the top of the table - which means that functions with a high priority are called first. So when using the C runtime, functions are called with high priority functions first, followed by low priority functions. <sect1>Pitfalls<p> When using these special symbols, please take care of the following: <itemize> <item> The linker will only generate function tables, it will not generate code to call these functions. If you're using the feature in some other than the existing C environments, you have to write code to call all functions in a linker generated table yourself. See the <tt/condes/ and <tt/callirq/ modules in the C runtime for an example on how to do this. <item> The linker will only add addresses of functions that are in modules linked to the executable. This means that you have to be careful where to place the condes functions. If initialization or an irq handler is needed for a group of functions, be sure to place the function into a module that is linked in regardless of which function is called by the user. <item> The linker will generate the tables only when requested to do so by the <tt/FEATURE CONDES/ statement in the linker config file. Each table has to be requested separately. <item> Constructors and destructors may have priorities. These priorities determine the order of the functions in the table. If your initialization or cleanup code does depend on other initialization or cleanup code, you have to choose the priority for the functions accordingly. <item> Besides the <tt><ref id=".CONSTRUCTOR" name=".CONSTRUCTOR"></tt>, <tt><ref id=".DESTRUCTOR" name=".DESTRUCTOR"></tt> and <tt><ref id=".INTERRUPTOR" name=".INTERRUPTOR"></tt> statements, there is also a more generic command: <tt><ref id=".CONDES" name=".CONDES"></tt>. This allows to specify an additional type. Predefined types are 0 (constructor), 1 (destructor) and 2 (interruptor). The linker generates a separate table for each type on request. </itemize> <sect>Porting sources from other assemblers<p> Sometimes it is necessary to port code written for older assemblers to ca65. In some cases, this can be done without any changes to the source code by using the emulation features of ca65 (see <tt><ref id=".FEATURE" name=".FEATURE"></tt>). In other cases, it is necessary to make changes to the source code. Probably the biggest difference is the handling of the <tt><ref id=".ORG" name=".ORG"></tt> directive. ca65 generates relocatable code, and placement is done by the linker. Most other assemblers generate absolute code, placement is done within the assembler and there is no external linker. In general it is not a good idea to write new code using the emulation features of the assembler, but there may be situations where even this rule is not valid. <sect1>TASS<p> You need to use some of the ca65 emulation features to simulate the behaviour of such simple assemblers. <enum> <item>Prepare your sourcecode like this: <tscreen><verb> ; if you want TASS style labels without colons .feature labels_without_colons ; if you want TASS style character constants ; ("a" instead of the default 'a') .feature loose_char_term .word *+2 ; the cbm load address [yourcode here] </verb></tscreen> notice that the two emulation features are mostly useful for porting sources originally written in/for TASS, they are not needed for the actual "simple assembler operation" and are not recommended if you are writing new code from scratch. <item>Replace all program counter assignments (which are not possible in ca65 by default, and the respective emulation feature works different from what you'd expect) by another way to skip to memory locations, for example the <tt><ref id=".RES" name=".RES"></tt> directive. <tscreen><verb> ; *=$2000 .res $2000-* ; reserve memory up to $2000 </verb></tscreen> Please note that other than the original TASS, ca65 can never move the program counter backwards - think of it as if you are assembling to disk with TASS. <item>Conditional assembly (<tt/.ifeq//<tt/.endif//<tt/.goto/ etc.) must be rewritten to match ca65 syntax. Most importantly notice that due to the lack of <tt/.goto/, everything involving loops must be replaced by <tt><ref id=".REPEAT" name=".REPEAT"></tt>. <item>To assemble code to a different address than it is executed at, use the <tt><ref id=".ORG" name=".ORG"></tt> directive instead of <tt/.offs/-constructs. <tscreen><verb> .org $1800 [floppy code here] .reloc ; back to normal </verb></tscreen> <item>Then assemble like this: <tscreen><verb> cl65 --start-addr 0x0ffe -t none myprog.s -o myprog.prg </verb></tscreen> Note that you need to use the actual start address minus two, since two bytes are used for the cbm load address. </enum> <sect>Copyright<p> ca65 (and all cc65 binutils) are (C) Copyright 1998-2003 Ullrich von Bassewitz. For usage of the binaries and/or sources the following conditions do apply: This software is provided 'as-is', without any expressed or implied warranty. In no event will the authors be held liable for any damages arising from the use of this software. Permission is granted to anyone to use this software for any purpose, including commercial applications, and to alter it and redistribute it freely, subject to the following restrictions: <enum> <item> The origin of this software must not be misrepresented; you must not claim that you wrote the original software. If you use this software in a product, an acknowledgment in the product documentation would be appreciated but is not required. <item> Altered source versions must be plainly marked as such, and must not be misrepresented as being the original software. <item> This notice may not be removed or altered from any source distribution. </enum> </article>