mirror of
https://github.com/KarolS/millfork.git
synced 2024-12-26 12:29:26 +00:00
199 lines
6.2 KiB
Markdown
199 lines
6.2 KiB
Markdown
[< back to index](../index.md)
|
|
|
|
# Using 8080/LR35902/Z80 assembly within Millfork programs
|
|
|
|
There are two ways to include raw assembly code in your Millfork programs:
|
|
|
|
* inline assembly code blocks
|
|
|
|
* whole assembly functions
|
|
|
|
## Assembly syntax
|
|
|
|
By default, Millfork uses Zilog syntax for Z80 and LR35902 assembly and Intel syntax for Intel 8080/8085 assembly.
|
|
This can be overridden per file by a pragma directive or by several other means.
|
|
Using both kinds of syntax in one file is not supported.
|
|
|
|
Indexing via the IX/IY register uses the following syntax: `IX(1)`
|
|
|
|
LR35902 instructions that load/store the accumulator indirectly via HL and then increment/decrement HL are written
|
|
`LD A,(HLI)`, `LD, A,(HLD)`, `LD (HLI),A` and `LD (HLD),A`
|
|
|
|
LR35902 instructions for faster access to the $FFxx addresses use the `LDH` mnemonic: `LDH A,(4)`, `LDH (C),A` etc.
|
|
|
|
Only instructions available on the current CPU architecture are available.
|
|
Intel syntax does not support instructions that are unavailable on the 8080.
|
|
Undocumented Z80 instructions are not supported, except for `SLL`.
|
|
|
|
Labels have to be followed by a colon and they can optionally be on a separate line.
|
|
Indentation is not important:
|
|
|
|
// Zilog syntax
|
|
first: INC a
|
|
second:
|
|
INC b
|
|
INC c
|
|
|
|
// Intel syntax
|
|
first: INR a
|
|
second:
|
|
INR b
|
|
INR c
|
|
|
|
|
|
Label names have to start with a letter and can contain digits, underscores and letters.
|
|
This means than they cannot start with a period like in many other assemblers.
|
|
Similarly, anonymous labels designated with `+` or `-` are also not supported.
|
|
|
|
Assembly can refer to variables and constants defined in Millfork,
|
|
but you need to be careful with using absolute vs immediate addressing:
|
|
|
|
const byte fiveConstant = 5
|
|
byte fiveVariable = 5
|
|
|
|
byte ten() {
|
|
byte result
|
|
asm {
|
|
// Zilog syntax
|
|
LD A, (fiveVariable) // not LD A,fiveVariable
|
|
ADD A,fiveConstant
|
|
LD (result), A
|
|
|
|
// Intel syntax
|
|
LDA fiveVariable // not MVI A,fiveVariable
|
|
ADD fiveConstant
|
|
STA result
|
|
}
|
|
return result
|
|
}
|
|
|
|
Any assembly opcode can be prefixed with `?`, which allows the optimizer change it or elide it if needed.
|
|
Opcodes without that prefix will be always compiled as written.
|
|
|
|
The '!' prefix marks the statement as volatile, which means it will be a subject to certain, but not all optimizations,
|
|
in order to preserve its semantics.
|
|
|
|
You can insert macros into assembly, by prefixing them with `+` and using the same syntax as in Millfork:
|
|
|
|
macro void run(byte x) {
|
|
output = x
|
|
}
|
|
|
|
byte output @$c000
|
|
|
|
void main () {
|
|
byte a
|
|
a = 7
|
|
asm {
|
|
+ run(a)
|
|
}
|
|
}
|
|
|
|
You can insert raw bytes into your assembly using the array syntax:
|
|
|
|
[ $00, $00 ]
|
|
"this is a string to print" bbc
|
|
["this is a string to print but this time it's zero-terminated so it will actually work" bbc, 0]
|
|
[for x,0,until,8 [x]]
|
|
|
|
## Assembly functions
|
|
|
|
Assembly functions can be declared as `macro` or not.
|
|
|
|
A macro assembly function is inserted into the calling function like an inline assembly block,
|
|
and therefore usually it shouldn't end with `RET`, `RETI` or `RETN`.
|
|
|
|
A non-macro assembly function should end with `RET`, `JP`, `RETI` or `RETN` (Zilog) / `RET` or `JMP` (Intel) as appropriate,
|
|
or it should be an external function.
|
|
|
|
For both macro and non-macro assembly functions,
|
|
the return type can be any valid return type, like for Millfork functions.
|
|
If the size of the return type is one byte,
|
|
then the result is passed via the A register.
|
|
If the size of the return type is two bytes,
|
|
then the result is passed via the HL register pair.
|
|
|
|
### Assembly function parameters
|
|
|
|
An assembly function can have parameters.
|
|
They differ from what is used by Millfork functions.
|
|
|
|
Macro assembly functions can have the following parameter types:
|
|
|
|
* reference parameters: `byte ref paramname`: every occurrence of the parameter will be replaced with the variable given as an argument
|
|
|
|
* constant parameters: `byte const paramname`: every occurrence of the parameter will be replaced with the constant value given as an argument
|
|
|
|
For example, if you have:
|
|
|
|
// Zilog syntax
|
|
macro asm void increase(byte ref v, byte const inc) {
|
|
LD A,(v)
|
|
ADD A,inc
|
|
LDA (v),A
|
|
}
|
|
|
|
// Intel syntax
|
|
macro asm void increase(byte ref v, byte const inc) {
|
|
LDA v
|
|
ADD inc
|
|
STA v
|
|
}
|
|
|
|
and call `increase(score, 10)`, the entire call will compile into:
|
|
|
|
// Zilog syntax
|
|
LD A,(score)
|
|
ADD A,10
|
|
LD (score),A
|
|
|
|
// Intel syntax
|
|
LDA score
|
|
ADD 10
|
|
STA score
|
|
|
|
Non-macro functions can only have their parameters passed via registers:
|
|
|
|
* `byte a`, `byte b`, etc.: a single byte passed via the given CPU register
|
|
|
|
* `word hl`, `word bc`, `word de`: a 2-byte word byte passed via given 16-bit register
|
|
|
|
**Work in progress**:
|
|
Currently, only few parameter signatures are supported for non-macro assembly functions:
|
|
|
|
* `()`
|
|
|
|
* `(byte a)`, `(byte b)`, `(byte c)`, `(byte d)`, `(byte e)`, `(byte h)`, `(byte l)` ("byte" may be any other 2-byte type)
|
|
|
|
* `(word hl)`, `(word bc)`, `(word de)` ("word" may be any other 2-byte type)
|
|
|
|
More parameters or parameters passed via other registers do not work yet.
|
|
|
|
Macro assembly functions cannot have any parameter passed via registers.
|
|
|
|
## Safe assembly
|
|
|
|
Since assembly gives the programmer unlimited access to all machine features,
|
|
certain assumptions about the code may be broken.
|
|
In order to make assembly cooperate with the rest of the Millfork code,
|
|
it should abide to the following rules:
|
|
|
|
* don't change the IX register
|
|
|
|
* don't change the IY register if the target platform doesn't allow it
|
|
(for example: ZX Spectrum in interrupt mode 1)
|
|
|
|
* don't jump between functions if either of functions has stack variables
|
|
|
|
* don't do `RET`, `RETI` or `RETN` if the function has stack variables
|
|
|
|
* don't jump or call things that are not functions or labels
|
|
|
|
* don't store data in locations other than variables or arrays
|
|
|
|
* don't change the stack pointer
|
|
|
|
* end non-inline assembly functions with `RET`, `JP`, `RETI` or `RETN` (Zilog) / `RET` or `JMP` (Intel) as appropriate
|
|
|
|
The above list is not exhaustive.
|