# Using 6502 assembly within Millfork programs
|
|
|
|
There are two ways to include raw assembly code in your Millfork programs:
|
|
|
|
* inline assembly code blocks
|
|
|
|
* whole assembly functions
|
|
|
|
## Assembly syntax
|
|
|
|
Millfork inline assembly uses the same three-letter opcodes as most other 6502 assemblers.
|
|
Indexing syntax is also the same. Only instructions available on the current CPU architecture are available.
|
|
|
|
**Work in progress**:
|
|
Currently, `RMBx`/`SMBx`/`BBRx`/`BBSx` and some extra 65CE02/HuC6280/65816 instructions are not supported yet.
|
|
|
|
Undocumented instructions are supported using various opcodes.
|
|
|
|
Labels have to be followed by a colon and they can optionally be on a separate line.
|
|
Indentation is not important:
|
|
|
|
first: INC x
|
|
second:
|
|
INC y
|
|
INC z
|
|
|
|
|
|
Label names have to start with a letter and can contain digits, underscores and letters.
|
|
This means than they cannot start with a period like in many other assemblers.
|
|
Similarly, anonymous labels designated with `+` or `-` are also not supported.
|
|
|
|
Assembly can refer to variables and constants defined in Millfork,
|
|
but you need to be careful with using absolute vs immediate addressing:
|
|
|
|
const byte fiveConstant = 5
|
|
byte fiveVariable = 5
|
|
|
|
byte ten() {
|
|
byte result
|
|
asm {
|
|
LDA #fiveConstant
|
|
CLC
|
|
ADC fiveVariable
|
|
STA result
|
|
}
|
|
return result
|
|
}
|
|
|
|
Any assembly opcode can be prefixed with `?`, which allows the optimizer change it or elide it if needed.
|
|
Opcodes without that prefix will be always compiled as written.
|
|
|
|
The '!' prefix marks the statement as volatile, which means it will be a subject to certain, but not all optimizations,
|
|
in order to preserve its semantics.
|
|
|
|
You can insert macros into assembly, by prefixing them with `+` and using the same syntax as in Millfork:
|
|
|
|
macro void run(byte x) {
|
|
output = x
|
|
}
|
|
|
|
byte output @$c000
|
|
|
|
void main () {
|
|
byte a
|
|
a = 7
|
|
asm {
|
|
+ run(a)
|
|
}
|
|
}
|
|
|
|
You can insert raw bytes into your assembly using the array syntax:
|
|
|
|
[ $EA, $EA ]
|
|
"this is a string to print" apple2
|
|
["this is a string to print but this time it's zero-terminated so it will actually work" apple2, 0]
|
|
[for x,0,until,8 [x]]
|
|
|
|
## Assembly functions
|
|
|
|
Assembly functions can be declared as `macro` or not.
|
|
|
|
A macro assembly function is inserted into the calling function like an inline assembly block,
|
|
and therefore usually it shouldn't end with `RTS` or `RTI`.
|
|
|
|
A non-macro assembly function should end with `RTS`, `JMP` or `RTI` as appropriate,
|
|
or it should be an external function.
|
|
|
|
For both macro and non-macro assembly functions,
|
|
the return type can be any valid return type, like for Millfork functions.
|
|
If the size of the return type is one byte,
|
|
then the result is passed via the accumulator.
|
|
If the size of the return type is two bytes,
|
|
then the low byte of the result is passed via the accumulator
|
|
and the high byte of the result is passed via the X register.
|
|
|
|
|
|
### Assembly function parameters
|
|
|
|
An assembly function can have parameters.
|
|
They differ from what is used by Millfork functions.
|
|
|
|
Macro assembly functions can have the following parameter types:
|
|
|
|
* reference parameters: `byte ref paramname`: every occurrence of the parameter will be replaced with the variable given as an argument
|
|
|
|
* constant parameters: `byte const paramname`: every occurrence of the parameter will be replaced with the constant value given as an argument
|
|
|
|
For example, if you have:
|
|
|
|
macro asm void increase(byte ref v, byte const inc) {
|
|
LDA v
|
|
CLC
|
|
ADC #inc
|
|
STA v
|
|
}
|
|
|
|
and call `increase(score, 10)`, the entire call will compile into:
|
|
|
|
LDA score
|
|
CLC
|
|
ADC #10
|
|
STA score
|
|
|
|
Non-macro functions can only have their parameters passed via registers:
|
|
|
|
* `byte a`, `byte x`, `byte y`: a single byte passed via the given CPU register; any 1-byte type can be used
|
|
|
|
* `word xa`, `word ax`, `word ay`, `word ya`, `word xy`, `word yx`: a 2-byte word byte passed via given two CPU registers,
|
|
with the high byte passed through the first register and the low byte passed through the second register; any 2-byte type can be used
|
|
|
|
For example, this piece of code:
|
|
|
|
asm void f(word ax) @F_ADDR extern
|
|
|
|
f(5)
|
|
|
|
will compile to
|
|
|
|
LDA #5
|
|
LDX #0
|
|
JSR F_ADDR
|
|
|
|
**Work in progress**:
|
|
Only the following combinations of register parameters work reliably:
|
|
|
|
* zero or one register parameters
|
|
|
|
* two register parameters where at least one of them is an 8-bit parameter passed via A
|
|
|
|
Other combinations are guaranteed to work only with constant arguments.
|
|
|
|
Macro assembly functions can have maximum one parameter passed via a register.
|
|
|
|
### External functions
|
|
|
|
An external function should be declared with a defined memory address
|
|
and the `extern` keyword instead of the body:
|
|
|
|
asm void putchar(byte a) @$FFD2 extern
|
|
|
|
## Safe assembly
|
|
|
|
Since assembly gives the programmer unlimited access to all machine features,
|
|
certain assumptions about the code may be broken.
|
|
In order to make assembly cooperate with the rest of the Millfork code,
|
|
it should abide to the following rules:
|
|
|
|
* don't leave the D flag set
|
|
|
|
* don't jump between functions if either of functions has stack variables
|
|
|
|
* don't do `RTS` or `RTI` if the function has stack variables
|
|
|
|
* don't jump or call things that are not functions or labels
|
|
|
|
* don't store data in locations other than variables or arrays
|
|
|
|
* don't change the stack pointer
|
|
|
|
* end non-inline assembly functions with `RTS`, `JMP` or `RTI` as appropriate
|
|
|
|
* on NMOS 6502:
|
|
|
|
* don't use `XAA`, `LXA`, `AHX`, `SHX`, `SHY`, `LAS` and `TAS` instructions
|
|
|
|
* on 65816:
|
|
|
|
* keep the direct page register set to $0000
|
|
|
|
* keep the M and X flags set to 1 (8-bit registers by default, native mode)
|
|
|
|
* if running in the native mode, be careful with the stack pointer (you should keep it between $000100 and $0001FF)
|
|
|
|
* do not change the data page register (keep an eye at the `PLD`, `MVN`, `MVP` instructions)
|
|
|
|
* explicitly use 16-bit immediate operands when appropriate; the assembler doesn't track flags and assumes 8-bit immediates by default (TODO: actually implement the 16-bit inline assembly correctly)
|
|
|
|
* use far jumps unless you're sure that the called function returns with an `RTS`
|
|
|
|
* on 65CE02:
|
|
|
|
* keep the `B` register set to $00
|
|
|
|
* don't change the `E` flag
|
|
|
|
* on HuC6280
|
|
|
|
* don't use the `SET` instruction
|
|
|
|
The above list is not exhaustive.
|