Oh actually the remaining test case did pass, I just had the wrong

completion PC

Streamline test harness a bit
This commit is contained in:
kris 2019-08-20 21:45:37 +01:00
parent 803632c15a
commit 7d5a29cbaa

View File

@ -2,10 +2,14 @@ import unittest
import sys
import py65.devices.mpu65c02
class KlausDormannTests(unittest.TestCase):
"""Runs Klaus Dormann's 6502-based test suites"""
def klausTestCase(self, filename, load_addr, pc, success_addr, should_trace=None):
MPU = py65.devices.mpu65c02.MPU
def klausTestCase(self, filename, load_addr, pc, completion_criteria,
should_trace=None):
mpu = self._make_mpu()
mpu.pc = pc
@ -18,20 +22,50 @@ class KlausDormannTests(unittest.TestCase):
while True:
old_pc = mpu.pc
mpu.step(trace=should_trace(mpu.pc))
if mpu.pc == old_pc:
if completion_criteria(mpu, old_pc):
break
assert mpu.pc == success_addr, "%s 0xb=%02x 0xc=%02x 0xd=%02x 0xf=%02x" % (
mpu, mpu.memory[0xb], mpu.memory[0xc], mpu.memory[0xd], mpu.memory[0xf])
return mpu
def make_completion_criteria(self, success_addr):
def completion_criteria(mpu, old_pc):
return mpu.pc == old_pc or mpu.pc == success_addr
return completion_criteria
def test6502FunctionalTest(self):
self.klausTestCase("devices/6502_functional_test.bin", 0x0, 0x400, 0x3399)
success_addr = 0x3399
completion_criteria = self.make_completion_criteria(success_addr)
# XXX fails
def Xtest65C02ExtendedOpcodesTest(self):
tracer = lambda pc: (0x1484 <= pc <= 0x16cc)
self.klausTestCase("devices/65C02_extended_opcodes_test_modified.bin"
"", 0xa, 0x400, 0x24a8) #, tracer)
mpu = self.klausTestCase(
"devices/6502_functional_test.bin", 0x0, 0x400,
completion_criteria
)
assert mpu.pc == success_addr, (
"%s 0xb=%02x 0xc=%02x 0xd=%02x 0xf=%02x" % (
mpu, mpu.memory[0xb], mpu.memory[0xc], mpu.memory[0xd],
mpu.memory[0xf])
)
def test65C02ExtendedOpcodesTest(self):
success_addr = 0x1570
completion_criteria = self.make_completion_criteria(success_addr)
# Modified version of 65C02_extended_opcodes_test that defines
# rkwl_wdc_op = 0 (don't test BBR/BBS instructions, which we do not
# implement) and many of the NOP tests for undefined opcodes which are
# not yet implemented here.
mpu = self.klausTestCase(
"devices/65C02_extended_opcodes_test_modified.bin", 0xa, 0x400,
completion_criteria
)
assert mpu.pc == success_addr, (
"%s 0xb=%02x 0xc=%02x 0xd=%02x 0xf=%02x" % (
mpu, mpu.memory[0xb], mpu.memory[0xc], mpu.memory[0xd],
mpu.memory[0xf])
)
# Test Helpers
@ -39,17 +73,15 @@ class KlausDormannTests(unittest.TestCase):
memory[start_address:start_address + len(bytes)] = bytes
def _make_mpu(self, *args, **kargs):
klass = self._get_target_class()
mpu = klass(*args, **kargs)
mpu = self.MPU(*args, **kargs)
if 'memory' not in kargs:
mpu.memory = 0x10000 * [0xAA]
return mpu
def _get_target_class(self):
return py65.devices.mpu65c02.MPU
def test_suite():
return unittest.findTestCases(sys.modules[__name__])
if __name__ == '__main__':
unittest.main(defaultTest='test_suite')