Benoît Thébaudeau f34731c1a9 cc2538: spi: Do not call SPI_WAITFOREORx() at end of init
If the SSI has never been used and spi_init() is called, then the SSI receive
FIFO is empty and remains so, so calling SPI_WAITFOREORx() at the end of
spi_init() waits endlessly for SSI_SR.RNE to be set. Hence, this call must be
removed in order to avoid a deadlock.

Signed-off-by: Benoît Thébaudeau <benoit.thebaudeau@advansee.com>
2013-11-15 15:56:40 +01:00
..