DaynaPort: Ignore commands with a bogus control value (#433)
All traffic from the DaynaPort will have a control value of 0xc0 or 0x80, so any commands that don't should be ignored. This helps the Mac Plus which will try to READ(6) from the DaynaPort device if it's attached at boot and then try to interpret the ethernet packet as hard drive data and crash. See issue akuker#419
This commit is contained in:
parent
f7ec0de834
commit
f2b5d86fa0
@ -506,6 +506,14 @@ void SCSIDaynaPort::Read6(SASIDEV *controller)
|
||||
record |= ctrl->cmd[3];
|
||||
ctrl->blocks=1;
|
||||
|
||||
// If any commands have a bogus control value, they were probably not
|
||||
// generated by the DaynaPort driver so ignore them
|
||||
if (ctrl->cmd[5] != 0xc0 && ctrl->cmd[5] != 0x80) {
|
||||
LOGTRACE("%s Control value %d, (%04X), returning invalid CDB", __PRETTY_FUNCTION__, ctrl->cmd[5], ctrl->cmd[5]);
|
||||
controller->Error(ERROR_CODES::sense_key::ILLEGAL_REQUEST, ERROR_CODES::asc::INVALID_FIELD_IN_CDB);
|
||||
return;
|
||||
}
|
||||
|
||||
LOGTRACE("%s READ(6) command record=%d blocks=%d", __PRETTY_FUNCTION__, (unsigned int)record, (int)ctrl->blocks);
|
||||
|
||||
ctrl->length = Read(ctrl->cmd, ctrl->buffer, record);
|
||||
|