mirror of
https://github.com/fadden/6502bench.git
synced 2024-11-30 01:50:10 +00:00
Make hint application less annoying
Two changes: (1) Code and data hints are now only applied to the first byte on each selected line. This allows you to slap a code hint on a string without lighting up the whole string. Inline-data hints and hint removal work as before. (2) Added a menu item (with Ctrl+D as shortcut) to toggle the state of the uncategorized data analyzer. This makes it easy to turn off the feature that put the code into a string in the first place.
This commit is contained in:
parent
93c76e219f
commit
9be99a7cac
12
SourceGen/AppForms/ProjectView.Designer.cs
generated
12
SourceGen/AppForms/ProjectView.Designer.cs
generated
@ -175,6 +175,7 @@ namespace SourceGen.AppForms
|
||||
this.symbolNameColumnHeader = ((System.Windows.Forms.ColumnHeader)(new System.Windows.Forms.ColumnHeader()));
|
||||
this.infoGroupBox = new System.Windows.Forms.GroupBox();
|
||||
this.infoTextBox = new System.Windows.Forms.TextBox();
|
||||
this.toggleDataScanToolStripMenuItem = new System.Windows.Forms.ToolStripMenuItem();
|
||||
this.mainMenuStrip.SuspendLayout();
|
||||
this.mainStatusStrip.SuspendLayout();
|
||||
this.mainToolStrip.SuspendLayout();
|
||||
@ -342,11 +343,13 @@ namespace SourceGen.AppForms
|
||||
this.toolStripMenuItem3,
|
||||
this.editHeaderCommentToolStripMenuItem,
|
||||
this.projectPropertiesToolStripMenuItem,
|
||||
this.toggleDataScanToolStripMenuItem,
|
||||
this.toolStripMenuItem7,
|
||||
this.settingsToolStripMenuItem});
|
||||
this.editToolStripMenuItem.Name = "editToolStripMenuItem";
|
||||
this.editToolStripMenuItem.Size = new System.Drawing.Size(39, 20);
|
||||
this.editToolStripMenuItem.Text = "Edit";
|
||||
this.editToolStripMenuItem.DropDownOpening += new System.EventHandler(this.editToolStripMenuItem_DropDownOpening);
|
||||
//
|
||||
// undoToolStripMenuItem
|
||||
//
|
||||
@ -1446,6 +1449,14 @@ namespace SourceGen.AppForms
|
||||
this.infoTextBox.Size = new System.Drawing.Size(177, 120);
|
||||
this.infoTextBox.TabIndex = 0;
|
||||
//
|
||||
// toggleDataScanToolStripMenuItem
|
||||
//
|
||||
this.toggleDataScanToolStripMenuItem.Name = "toggleDataScanToolStripMenuItem";
|
||||
this.toggleDataScanToolStripMenuItem.ShortcutKeys = ((System.Windows.Forms.Keys)((System.Windows.Forms.Keys.Control | System.Windows.Forms.Keys.D)));
|
||||
this.toggleDataScanToolStripMenuItem.Size = new System.Drawing.Size(207, 22);
|
||||
this.toggleDataScanToolStripMenuItem.Text = "Toggle Data Scan";
|
||||
this.toggleDataScanToolStripMenuItem.Click += new System.EventHandler(this.toggleDataScanToolStripMenuItem_Click);
|
||||
//
|
||||
// ProjectView
|
||||
//
|
||||
this.AutoScaleDimensions = new System.Drawing.SizeF(6F, 13F);
|
||||
@ -1631,6 +1642,7 @@ namespace SourceGen.AppForms
|
||||
private System.Windows.Forms.ToolStripMenuItem editProjectSymbolToolStripMenuItem;
|
||||
private System.Windows.Forms.ToolStripMenuItem deleteNoteCommentToolStripMenuItem;
|
||||
private System.Windows.Forms.ToolStripMenuItem formatSplitAddressTableToolStripMenuItem;
|
||||
private System.Windows.Forms.ToolStripMenuItem toggleDataScanToolStripMenuItem;
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -602,6 +602,7 @@ namespace SourceGen.AppForms {
|
||||
gotoToolStripMenuItem.Enabled = true;
|
||||
editHeaderCommentToolStripMenuItem.Enabled = true;
|
||||
projectPropertiesToolStripMenuItem.Enabled = true;
|
||||
toggleDataScanToolStripMenuItem.Enabled = true;
|
||||
|
||||
showUndoRedoHistoryToolStripMenuItem.Enabled = true;
|
||||
showAnalysisTimersToolStripMenuItem.Enabled = true;
|
||||
@ -633,6 +634,7 @@ namespace SourceGen.AppForms {
|
||||
gotoToolStripMenuItem.Enabled = false;
|
||||
editHeaderCommentToolStripMenuItem.Enabled = false;
|
||||
projectPropertiesToolStripMenuItem.Enabled = false;
|
||||
toggleDataScanToolStripMenuItem.Enabled = false;
|
||||
|
||||
showUndoRedoHistoryToolStripMenuItem.Enabled = false;
|
||||
showAnalysisTimersToolStripMenuItem.Enabled = false;
|
||||
@ -1896,6 +1898,16 @@ namespace SourceGen.AppForms {
|
||||
}
|
||||
}
|
||||
|
||||
// Edit > Toggle Data Scan
|
||||
private void toggleDataScanToolStripMenuItem_Click(object sender, EventArgs e) {
|
||||
ProjectProperties oldProps = mProject.ProjectProps;
|
||||
ProjectProperties newProps = new ProjectProperties(oldProps);
|
||||
newProps.AnalysisParams.AnalyzeUncategorizedData =
|
||||
!newProps.AnalysisParams.AnalyzeUncategorizedData;
|
||||
UndoableChange uc = UndoableChange.CreateProjectPropertiesChange(oldProps, newProps);
|
||||
ApplyUndoableChanges(new ChangeSet(uc));
|
||||
}
|
||||
|
||||
// Edit > Settings...
|
||||
private void settingsToolStripMenuItem_Click(object sender, EventArgs e) {
|
||||
ShowAppSettings(EditAppSettings.Tab.Unknown);
|
||||
@ -2473,6 +2485,13 @@ namespace SourceGen.AppForms {
|
||||
return -1;
|
||||
}
|
||||
|
||||
|
||||
private void editToolStripMenuItem_DropDownOpening(object sender, EventArgs e) {
|
||||
// Set the checkmark on Toggle Data Scan.
|
||||
toggleDataScanToolStripMenuItem.Checked = (mProject != null) &&
|
||||
mProject.ProjectProps.AnalysisParams.AnalyzeUncategorizedData;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Handles an "opening" event for the codeListView's ContextMenuStrip.
|
||||
///
|
||||
@ -2951,19 +2970,33 @@ namespace SourceGen.AppForms {
|
||||
}
|
||||
|
||||
private void MarkAsCode_Click(Object sender, EventArgs e) {
|
||||
MarkAsType(CodeAnalysis.TypeHint.Code);
|
||||
MarkAsType(CodeAnalysis.TypeHint.Code, true);
|
||||
}
|
||||
private void MarkAsData_Click(Object sender, EventArgs e) {
|
||||
MarkAsType(CodeAnalysis.TypeHint.Data);
|
||||
MarkAsType(CodeAnalysis.TypeHint.Data, true);
|
||||
}
|
||||
private void MarkAsInlineData_Click(Object sender, EventArgs e) {
|
||||
MarkAsType(CodeAnalysis.TypeHint.InlineData);
|
||||
MarkAsType(CodeAnalysis.TypeHint.InlineData, false);
|
||||
}
|
||||
private void MarkAsNoHint_Click(Object sender, EventArgs e) {
|
||||
MarkAsType(CodeAnalysis.TypeHint.NoHint);
|
||||
MarkAsType(CodeAnalysis.TypeHint.NoHint, false);
|
||||
}
|
||||
private void MarkAsType(CodeAnalysis.TypeHint hint) {
|
||||
RangeSet sel = OffsetSetFromSelected();
|
||||
private void MarkAsType(CodeAnalysis.TypeHint hint, bool firstByteOnly) {
|
||||
RangeSet sel;
|
||||
|
||||
if (firstByteOnly) {
|
||||
sel = new RangeSet();
|
||||
foreach (int index in codeListView.SelectedIndices) {
|
||||
int offset = mDisplayList[index].FileOffset;
|
||||
if (offset >= 0) {
|
||||
// Not interested in the header stuff for hinting.
|
||||
sel.Add(offset);
|
||||
}
|
||||
}
|
||||
} else {
|
||||
sel = OffsetSetFromSelected();
|
||||
}
|
||||
|
||||
TypedRangeSet newSet = new TypedRangeSet();
|
||||
TypedRangeSet undoSet = new TypedRangeSet();
|
||||
|
||||
|
@ -16,7 +16,7 @@ and 65816 code. The official web site is
|
||||
<a href="https://6502bench.com/">https://6502bench.com/</a>.</p>
|
||||
|
||||
<p>If you want to dive right in, try the
|
||||
<a href="tutorials.html">Tutorial</a>.</p>
|
||||
<a href="tutorials.html">Tutorials</a>.</p>
|
||||
|
||||
<h2>Contents</h2>
|
||||
<ul>
|
||||
@ -56,6 +56,7 @@ and 65816 code. The official web site is
|
||||
<li><a href="mainwin.html#hints">Adding and Removing Hints</a></li>
|
||||
<li><a href="mainwin.html#split-address">Format Split-Address Table</a></li>
|
||||
<li><a href="mainwin.html#toggle-format">Quick Format Toggle</a></li>
|
||||
<li><a href="mainwin.html#toggle-data">Toggle Data Scan</a></li>
|
||||
<li><a href="mainwin.html#clipboard">Copying to Clipboard</a></li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
@ -241,7 +241,7 @@ L1009 CLC
|
||||
</pre>
|
||||
|
||||
<p>Be careful that you only add hints to the instruction opcode. If
|
||||
you selected the full range of bytes from $1003 to $1008, you would
|
||||
you applied hints to the full range of bytes from $1003 to $1008, you would
|
||||
end up with this:</p>
|
||||
<pre>
|
||||
.ORG $1000
|
||||
@ -257,7 +257,9 @@ L1009 CLC
|
||||
The problem is that the bytes in the middle of the instruction have
|
||||
been marked as entry points, and SourceGen is treating them as
|
||||
embedded instructions. $EF and $12 aren't valid 6502 opcodes, so
|
||||
they're being ignored, but $10 is BPL and $30 is BMI.</p>
|
||||
they're being ignored, but $10 is BPL and $30 is BMI. Because hinting
|
||||
multiple consecutive bytes is rarely useful, SourceGen only applies code
|
||||
hints to the first byte in a selected line.</p>
|
||||
|
||||
<p><b>Data hints</b> tell the analyzer when it should stop. For example,
|
||||
suppose address $ff00 is known to always be nonzero, and the code uses
|
||||
@ -276,6 +278,8 @@ the BNE that sets Z=0, so the code tracer will know it's a branch-always
|
||||
and do the right thing.) It's only necessary to place a hint on the
|
||||
very first (opcode) byte. Placing a data hint in the middle of what
|
||||
SourceGen believes to be instruction will have no effect.</p>
|
||||
<p>As with code hints, only the first byte in each selected line will
|
||||
be hinted.</p>
|
||||
|
||||
<p><b>Inline data hints</b> identify bytes as being part of the
|
||||
instruction stream, but not instructions. A simple example of this
|
||||
@ -289,7 +293,8 @@ is the ProDOS 8 call interface on the Apple II, which looks like this:</p>
|
||||
|
||||
<p>The three bytes following the <code>JSR $bf00</code> should be hinted
|
||||
as inline data, so that the code analyzer skips them and continues the
|
||||
analysis at the <code>BCS</code>.</p>
|
||||
analysis at the <code>BCS</code>. Because you need to hint *every* byte
|
||||
of inline data, all bytes in a selected line will receive hints.</p>
|
||||
<p>If code branches into a region that is marked as inline data, the
|
||||
branch will be ignored.</p>
|
||||
|
||||
|
@ -281,20 +281,26 @@ Ctrl+- / Ctrl+Shift+-, as keyboard shortcuts.)</p>
|
||||
|
||||
<h3><a name="hints">Adding and Removing Hints</a></h3>
|
||||
|
||||
<p>To add code entry or data hints, select the offsets with the instruction
|
||||
opcodes, and then use the "Hint as Code Entry Point" or "Hint as Data"
|
||||
menu item. Remember to avoid hinting additional bytes, especially with
|
||||
code entry points, as that can lead to unwanted embedded instructions.</p>
|
||||
<p>For inline data, select all of the data that the code analyzer should
|
||||
skip, and use the "Hint as Inline Data" menu item.</p>
|
||||
<p>To add code entry or data hints, select the desired offsets and
|
||||
use Actions > Hint As Code Entry Point or Hint As Data. Because code
|
||||
hints mean "the code analyzer should start here", and data hints mean
|
||||
"the code analyzer should stop here", there is rarely any reason to hint
|
||||
multiple consecutive bytes. For this reason, only the first byte on each
|
||||
selected line will be hinted.</p>
|
||||
<p>For inline data, you need to hint every byte, so every byte in every
|
||||
selected line is hinted when you select Hint As Inline Data. Similarly,
|
||||
the Remove Hints menu item will remove hints from every byte.</p>
|
||||
|
||||
<p>If you're having a hard time selecting just the right bytes because
|
||||
the instructions are caught up in a multi-byte data item, such as an
|
||||
auto-detected ASCII string, you can use the "Toggle Single-Byte Format"
|
||||
menu item to "flatten" the item. Apply the hint, then toggle the bytes
|
||||
back to default format. You can also disable uncategorized data analysis
|
||||
entirely from the
|
||||
<a href="settings.html#project-properties">project properties</a> editor.
|
||||
auto-detected ASCII string, you can disable uncategorized data analysis
|
||||
(the thing that creates the .STR and .FILL ops for you). You can do this
|
||||
from the
|
||||
<a href="settings.html#project-properties">project properties</a> editor,
|
||||
or simply by hitting Ctrl+D. Hit that, apply the hint, then hit it
|
||||
again to re-enable the string & fill analyzer.</p>
|
||||
<p>Another approach is to can use the "Toggle Single-Byte Format"
|
||||
menu item to "flatten" the item.</p>
|
||||
|
||||
|
||||
<h3><a name="split-address">Format Split-Address Table</a></h3>
|
||||
@ -392,6 +398,18 @@ selecting "Default".</p>
|
||||
string, but you want to see it as bytes or set a label in the middle.</p>
|
||||
|
||||
|
||||
<h3><a name="toggle-data">Toggle Data Scan</a></h3>
|
||||
|
||||
<p>This menu item is in the Edit menu, and acts as a shortcut to opening
|
||||
the Project Properties editor, and clicking on the "Analyze Uncategorized
|
||||
Data" checkbox. When enabled, SourceGen will look for ASCII strings and
|
||||
regions of identical bytes, and generate .STR and .FILL directives. When
|
||||
disabled, uncategorized data is presented as one byte per line, which can
|
||||
be handy if you're trying to get at a bit in the middle of a string.</p>
|
||||
<p>As with all other project properties changes, this is an undoable
|
||||
event.</p>
|
||||
|
||||
|
||||
<h3><a name="clipboard">Copying to Clipboard</a></h3>
|
||||
|
||||
<p>When you use Edit > Copy, all lines selected in the code list are
|
||||
|
Loading…
Reference in New Issue