1
0
mirror of https://github.com/fadden/6502bench.git synced 2024-12-11 13:50:13 +00:00
Commit Graph

31 Commits

Author SHA1 Message Date
Andy McFadden
34ba47e71d Add W65C02S support, part 3
Modified the asm source generators and on-screen display to show the
DP arg for BBR/BBS as hex.  The instructions are otherwise treated
as relative branches, e.g. the DP arg doesn't get factored into the
cross-reference table.

ACME/cc65 put the bit number in the mnemonic, 64tass wants it to be
in the first argument, and Merlin32 wants nothing to do with any of
this because it's incompatible with the 65816.

Added an "all ops" test for W65C02.
2020-10-11 14:35:17 -07:00
Andy McFadden
b60dc4fee4 Add W65C02S support, part 1
We were claiming W65C02S, but it turns out that CPU has the Rockwell
extensions and the STP/WAI instructions.  We need to change existing
references to be "WDC 65C02", and add a new CPU definition for the
actual W65C02S chip.

This adds the new CPU definition, the instruction definitions for
the Rockwell extensions, and updates the selectors in project properties
and the instruction chart tool.

This change shouldn't affect any existing projects.  Still more to do
before W65C02 works though, mostly because the Rockwell instructions
introduced a new two-argument address mode that has to be handled in
various places.
2020-10-10 15:46:34 -07:00
Andy McFadden
cb6ceafd73 Make operand wrap length configurable
Long operands, such as strings and bulk data, can span multiple lines.
SourceGen wraps them at 64 characters, which is fine for assembly
output but occasionally annoying on screen: if the operand column is
wide enough to show the entire value, the comment column is pushed
pretty far to the right.

This change makes the width configurable, as 32/48/64 characters,
with a pop-up in app settings.

The assemblers are all wired to 64 characters, though we could make
this configurable as well with an assembler-specific setting.

Some things have moved around a bit in app settings.  The Asm Config
tab now comes last.  Having it sandwiched in the middle of tabs that
altered the on-screen display didn't make much sense.  The Display
Format is now explicitly for opcodes and operands, and is split into
two columns.  The left column is managed by the "quick set" feature,
the right column is independent.
2020-07-19 18:39:27 -07:00
Andy McFadden
86ead987d5 Tweak OMF converter
Changed bank-start comments to notes, added a summary to the top-of-file
comment.

Also, fixed a bug where the app settings dialog wasn't identifying
display settings as a preset for 64tass and cc65.
2020-06-30 11:48:11 -07:00
Andy McFadden
b43fd07688 Split 2002x-operand-formats test
My original goal was to add a sign-extended decimal format, but that
turned out to be awkward.  It works for data items and instructions
with immediate operands (e.g. "LDA #-1"), but is either wrong or
useless for address operands, since most assemblers treat integers
as 32-bit values.  (LDA -1 is not LDA $FFFF, it's LDA $FFFFFFFF,
which is not useful unless your asm is doing an implicit mod.)

There's also a bit of variability in how assemblers treat negative
values, so I'm shelving the idea for now.  I'm keeping the updated
tests, which are now split into 6502 / 65816 parts.

Also, updated the formatter to output all decimal values as unsigned.
Most assemblers were fine with negative values, but 64tass .dword
insists on positive.  Rather than make the opcode conditional on the
value's range, we now just always output unsigned decimal, which
all current assemblers accept.
2020-06-08 17:47:26 -07:00
Andy McFadden
8209753cbc Fix hex format string initialization
For some reason FormatHexValue was creating format strings on
demand.  In a recent change, FormatAdjustment started using them.
So if the first 4-digit hex value printed by the program was a
large adjustment, you could end up with a default-formatted adjustment
pretending to be hex.

Now we just create the 4 format strings in the Formatter constructor.
2020-02-11 16:38:51 -08:00
Andy McFadden
5548469ba1 Show large adjustments in hex
We emit address adjustments like "LDA thing+1", which are usually
small values.  Sometimes they're large, e.g. "LDA thing-61440",
which is harder to understand than "LDA thing-$F000".  So now we
show small adjustments in decimal, and large adjustments in hex.

The current definition of "small" is abs(adjust) < 256.
2020-01-02 13:09:18 -08:00
Andy McFadden
1373ffd8e3 Add file slicer tool
The tool allows you to cut a piece out of a file by specifying an
offset and a length.  A pair of hex dumps helps you verify that the
positions are correct.

Also, minor cleanups elsewhere.
2019-12-29 17:59:35 -08:00
Andy McFadden
071adb8e95 Two changes to "dense hex" bulk data formatting
(1) Added an option to limit the number of bytes per line.  This is
handy for things like bitmaps, where you might want to put (say) 3
or 8 bytes per line to reflect the structure.

(2) Added an application setting that determines whether the screen
listing shows Merlin/ACME dense hex (20edfd) or 64tass/cc65 hex bytes
($20,$ed,$fd).  Made the setting part of the assembler-driven display
definitions.  Updated 64tass+cc65 to use ".byte" as their dense hex
pseudo-op, and to use the updated formatter code.  No changes to
regression test output.

(Changes were requested in issue #42.)

Also, added a resize gripper to the bottom-right corner of the main
window.  (These seem to have generally fallen out of favor, but I
like having it there.)
2019-12-10 17:41:00 -08:00
Andy McFadden
5dd7576529 Label rework, part 2
Continue development of non-unique labels.  The actual labels are
still unique, because we append a uniquifier tag, which gets added
and removed behind the scenes.  We're currently using the six-digit
hex file offset because this is only used for internal address
symbols.

The label editor and most of the formatters have been updated.  We
can't yet assemble code that includes non-unique labels, but older
stuff hasn't been broken.

This removes the "disable label localization" property, since that's
fundamentally incompatible with what we're doing, and adds a non-
unique label prefix setting so you can put '@' or ':' in front of
your should-be-local labels.

Also, fixed a field name typo.
2019-11-12 17:44:51 -08:00
Andy McFadden
4d079c8d14 Label rework, part 1
This adds the concept of label annotations.  The primary driver of
the feature is the desire to note that sometimes you know what a
thing is, but sometimes you're just taking an educated guess.
Instead of writing "high_score_maybe", you can now write "high_score?",
which is more compact and consistent.  The annotations are stripped
off when generating source code, making them similar to Notes.

I also created a "Generated" annotation for the labels that are
synthesized by the address table formatter, but don't modify the
label for them, because there's not much need to remind the user
that "T1234" was generated by algorithm.

This also lays some of the groundwork for non-unique labels.
2019-11-08 21:02:15 -08:00
Andy McFadden
dfd5bcab1b Optionally treat BRKs as two-byte instructions
Early data sheets listed BRK as one byte, but RTI after a BRK skips
the following byte, effectively making BRK a 2-byte instruction.
Sometimes, such as when diassembling Apple /// SOS code, it's handy
to treat it that way explicitly.

This change makes two-byte BRKs optional, controlled by a checkbox
in the project settings.  In the system definitions it defaults to
true for Apple ///, false for all others.

ACME doesn't allow BRK to have an arg, and cc65 only allows it for
65816 code (?), so it's emitted as a hex blob for those assemblers.
Anyone wishing to target those assemblers should stick to 1-byte mode.

Extension scripts have to switch between formatting one byte of
inline data and formatting an instruction with a one-byte operand.
A helper function has been added to the plugin Util class.

To get some regression test coverage, 2022-extension-scripts has
been configured to use two-byte BRK.

Also, added/corrected some SOS constants.

See also issue #44.
2019-10-09 14:55:56 -07:00
Andy McFadden
6a2532588b Local variables mostly work
Variables are now handled properly end-to-end, except for label
uniquification.  So cc65 and ACME can't yet handle a file that
redefines a local variable.

This required a bunch of plumbing, but I think it came out okay.
2019-08-30 18:39:29 -07:00
Andy McFadden
268ad18067 Add C64 character conversions to hex dump viewer
The conversion mode enum was replaced, so we will lose the previous
combo box setting after an upgrade.
2019-08-16 15:45:42 -07:00
Andy McFadden
81029afae5 Generate C64 encodings in 64tass output
The 64tass generator now uses the "default text encoding" project
property to determine how readable text should be encoded.  For
example, if the property is set to PETSCII, an ASCII-to-PETSCII
encoding table is generated at the top of the output file.
2019-08-16 14:46:17 -07:00
Andy McFadden
7bbe5692bd Add C64 encodings to instruction and data operand editors
Both dialogs got a couple extra radio buttons for selection of
single character operands.  The data operand editor got a combo box
that lets you specify how it scans for viable strings.

Various string scanning methods were made more generic.  This got a
little strange with auto-detection of low/high ASCII, but that was
mostly a matter of keeping the previous code around as a special
case.

Made C64 Screen Code DCI strings a thing that works.
2019-08-15 17:53:12 -07:00
Andy McFadden
8fd469b81f Correctly handle delimiters in character operands
We weren't checking to see if character operands matched their
delimiters, so bad code like "LDA #'''" was being generated.

There wasn't a test for this in 2006-operand-formats, so the test
has been updated with single and double quotes in low and high ASCII.
2019-08-14 17:31:15 -07:00
Andy McFadden
beb1024550 Define and use "delimiter sets"
A delimiter definition is four strings (prefix, open, close, suffix)
that are concatenated with the character or string data to form an
operand.  A delimiter set is a collection of delimiter definitions,
with separate entries for each character encoding.

This is a convenient way to configure Formatter objects, import and
export data from the app settings file, and manage the UI needed to
allow the user to customize how things look.

The full set of options didn't fit on the first app settings tab, so
there's now a separate tab just for specifying character and string
delimiters.  (This might be overkill, but there are various plausible
scenarios that make use of it.)

The delimiters for on-screen display of strings can now be
configured.
2019-08-14 16:10:04 -07:00
Andy McFadden
5889f45737 Replace on-screen string operand formatting
The previous functions just grabbed 62 characters and slapped quotes
on the ends, but that doesn't work if we want to show strings with
embedded control characters.  This change replaces the simple
formatter with the one used to generate assembly source code.  This
increases the cost of refreshing the display list, so a cache will
need to be added in a future change.

Converters for C64 PETSCII and C64 Screen Code have been defined.
The results of changing the auto-scan encoding can now be viewed.

The string operand formatter was using a single delimiter, but for
the on-screen version we want open-quote and close-quote, and might
want to identify some encodings with a prefix.  The formatter now
takes a class that defines the various parts.  (It might be worth
replacing the delimiter patterns recently added for single-character
operands with this, so we don't have two mechanisms for very nearly
the same thing.)

While working on this change I remembered why there were two kinds
of "reverse" in the old Merlin 32 string operand generator: what you
want for assembly code is different from what you want on screen.
The ReverseMode enum has been resurrected.
2019-08-13 17:52:58 -07:00
Andy McFadden
9a6d8d2e28 Minor cleanup
Remove left/right arrow PNGs.  Remove duplicate copies of icon.
Tweak some comments.  Set application icon.  Adjust padding on
group boxes in first tab of app settings.
2019-08-12 14:13:27 -07:00
Andy McFadden
f33cd7d8a6 Replace character operand output method
The previous code output a character in single-quotes if it was
standard ASCII, double-quotes if high ASCII, or hex if it was neither
of those.  If a flag was set, high ASCII would also be output as
hex.

The new system takes the character value and an encoding identifier.
The identifier selects the character converter and delimiter
pattern, and puts the two together to generate the operand.

While doing this I realized that I could trivially support high
ASCII character arguments in all assemblers by setting the delimiter
pattern to "'#' | $80".

In FormatDescriptor, I had previously renamed the "Ascii" sub-type
"LowAscii" so it wouldn't be confused, but I dislike filling the
project file with "LowAscii" when "Ascii" is more accurate and less
confusing.  So I switched it back, and we now check the project
file version number when deciding what to do with an ASCII item.
The CharEncoding tests/converters were also renamed.

Moved the default delimiter patterns to the string table.

Widened the delimiter pattern input fields slightly.  Added a read-
only TextBox with assorted non-typewriter quotes and things so
people have something to copy text from.
2019-08-11 22:11:00 -07:00
Andy McFadden
1ad9caa783 First pass at ACME support
I managed to work around most of the quirks, but there's still an
issue with 65816 code.

Also, enabled word wrapping in the AsmGen text boxes.
2019-08-03 20:54:07 -07:00
Andy McFadden
98914e9f80 Treat BRK as a 1-byte instruction
The 65816 definition makes it a two-byte instruction, like COP.  On
the 6502 it acted like a two-byte instruction, but in practice very
few assemblers treat it that way.  Very few humans, for that matter.
So it's now treated as a single byte instruction, with the following
byte encoded as a data value.
2019-08-02 17:21:50 -07:00
Andy McFadden
0d75282756 Minor tweaks 2019-07-13 11:29:05 -07:00
Andy McFadden
0041584d2e Rework NavStack
Instead of traversing a single dual-element stack, use separate
stacks for forward and backward.

Record whether the jump was from a Note, so we select the right
set of lines when we return to it.

If nothing is selected, push the current top position on, instead
of doing nothing at all.

Correctly handle the case where somebody is trying to jump to the
current position.
2019-06-22 11:36:08 -07:00
Andy McFadden
a88c746419 Work around cc65 single-pass behavior
The cc65 assembler runs in a single pass, which means forward
address references default to 16 bits.  For zero-page references
we have to add an explicit width disambiguator.  (This is an
unusual situation that only occurs if you have a zero-page .ORG
in the file after code that references it.)

With this change, 2014-label-dp passes, and no other regression
tests were affected.

(issue #40)
2018-11-02 15:32:54 -07:00
Andy McFadden
da91f86043 Get 64tass expressions working
We now insert parenthesis as needed.  This can cause problems in
some situations, so we always prefix parenthetical expressions with
"0+", which looks goofy and is unnecessary for immediate operands.
But it does generate working source code.

Renamed the "simple" expression mode to "common", as it's not
particularly simple but is what you'd expect most assemblers to do.
(OTOH, life has been full of surprises.)

(issue #16)
2018-10-24 14:57:09 -07:00
Andy McFadden
61914c8f79 Progress toward 64tass expression support
Gave cc65 its own expression generator, as the precedence table seems
atypical if not unique.  Configured 64tass to use the "simple"
expression mode.

Added some operations on a 32-bit constant to 2007-labels-and-symbols
to exercise the current worst-case expression (shift + AND + add).
Tweaked the Merlin expression generator to handle it.

(issue #16)
2018-10-24 13:17:03 -07:00
Andy McFadden
f7e5cf2f45 Progress toward 64tass support
Most tests pass, but 2007-labels-and-symbols fails because the
expressions recognized by 64tass don't match up with either of the
other assemblers.

This is currently using a workaround for the local label syntax.
64tass uses '_' as the prefix, which is unfortunate since SourceGen
explicitly allowed underscores in labels.  (So does 64tass for that
matter, but it treats labels specially when the '_' comes first.)
We will need to rename any non-local user labels that start with '_'.

(issue #16)
2018-10-23 20:08:01 -07:00
Andy McFadden
96ee33ae8c Optionally add spaces in the "bytes" column
Affects the display list and copy/paste text.  Makes the column
three spaces wider, but makes it easier to read.
2018-10-21 21:08:48 -07:00
Andy McFadden
2c6212404d Initial file commit 2018-09-28 10:05:11 -07:00