Added "show undocumented opcodes" checkbox, so you can choose
whether or not to see them at all. (Issue #60)
Added formatter call for the instruction mnemonics so they get
capitalized when the app is configured for upper-case opcodes.
(Issue #59)
Fix a bug where the instruction chart and ASCII chart were writing
their modes to the same setting, stomping each other.
Also, pluralized a button in the file concatenator.
We now generate GIF images for visualizations and add inline
references to them in the HTML output.
Images are scaled using the HTML img properties. This works well
on some browsers, but others insist on "smooth" scaling that blurs
out the pixels. This may require a workaround.
An extra blank line is now added above visualizations. This helps
keep the image and data visually grouped.
The Apple II bitmap test project was updated to have a visualization
set with multiple images at the top of the file.
(1) Added an option to limit the number of bytes per line. This is
handy for things like bitmaps, where you might want to put (say) 3
or 8 bytes per line to reflect the structure.
(2) Added an application setting that determines whether the screen
listing shows Merlin/ACME dense hex (20edfd) or 64tass/cc65 hex bytes
($20,$ed,$fd). Made the setting part of the assembler-driven display
definitions. Updated 64tass+cc65 to use ".byte" as their dense hex
pseudo-op, and to use the updated formatter code. No changes to
regression test output.
(Changes were requested in issue #42.)
Also, added a resize gripper to the bottom-right corner of the main
window. (These seem to have generally fallen out of favor, but I
like having it there.)
The label localizer is now always on. The regression tests turned
it off by default, but that's no longer allowed, so the generated
output has changed for many of them. The tests themselves were not
altered.
Added serialization of non-unique labels to project files.
The address labels are stored without the non-unique tag, because we
can get that from the file offset. (If we stored it, we'd need to
extract the value and verify that it matches the offset.) Operand
weak references are symbolic, and so do include the tag string.
We weren't validating symbol labels before. Now we are.
This also adds a "NonU" filter to the Symbols window so the labels
can be shown or hidden as desired.
Also, added source for a first pass at a regression test.
Continue development of non-unique labels. The actual labels are
still unique, because we append a uniquifier tag, which gets added
and removed behind the scenes. We're currently using the six-digit
hex file offset because this is only used for internal address
symbols.
The label editor and most of the formatters have been updated. We
can't yet assemble code that includes non-unique labels, but older
stuff hasn't been broken.
This removes the "disable label localization" property, since that's
fundamentally incompatible with what we're doing, and adds a non-
unique label prefix setting so you can put '@' or ':' in front of
your should-be-local labels.
Also, fixed a field name typo.
This adds a window that displays all of the instructions for a
given CPU in a summary grid. Undocumented instructions are
included, but shown in grey italics.
Also, tweaked AppSettings to not mark itself as dirty if a "set"
operation doesn't actually change anything.
Implemented show/hide mechanic, using a button on the right side of
the status bar to show status and to trigger un-hide.
Also, show I/O direction in project symbols editor list.
Most of SourceGen uses standard WPF controls, which get their default
style from the system theme. The main disassembly list uses a
custom style, and always looks like the Windows default theme.
Some people greatly prefer white text on a black background, so we
now provide a way to get that. This also requires muting the colors
used for Notes, since those were chosen to contrast with black text.
This does not affect anything other than the ListView used for
code, because everything else can be set through the Windows
"personalization" interface. We might want to change the way the
Notes window looks though, to avoid having glowing bookmarks on
the side.
It felt a little weird tying it to the asm generation setting,
so now it's just another checkbox in the export options.
Implemented the feature for plain text output. Did some rearranging
in the code. Fixed suppression of Notes in text and CSV.
Also, removed "include symbol table" from export dialog. You can
exclude the table by removing it from the template, which right
now you'd need to do anyway to get rid of the H2 header and other
framing. To make this work correctly as an option we'd need to
parse the "div" in the template file and strip the whole section,
or split the template into multiple parts that get included as
needed. Not worth doing the work until we're sure it matters.
This feature "exports" the source code in the same format it appears
in on screen. The five columns on the left are optional, the four
on the right can be resized. Exported text can span the entire file
or just the current selection. Output can be plain text or CSV.
(I still haven't figured out a good use for CSV.)
The old copy-to-clipboard function is now implemented via the export
mechanism.
This adds a new clipboard mode that includes all columns. Potentially
useful for filing bug reports against SourceGen.
Both dialogs got a couple extra radio buttons for selection of
single character operands. The data operand editor got a combo box
that lets you specify how it scans for viable strings.
Various string scanning methods were made more generic. This got a
little strange with auto-detection of low/high ASCII, but that was
mostly a matter of keeping the previous code around as a special
case.
Made C64 Screen Code DCI strings a thing that works.
A delimiter definition is four strings (prefix, open, close, suffix)
that are concatenated with the character or string data to form an
operand. A delimiter set is a collection of delimiter definitions,
with separate entries for each character encoding.
This is a convenient way to configure Formatter objects, import and
export data from the app settings file, and manage the UI needed to
allow the user to customize how things look.
The full set of options didn't fit on the first app settings tab, so
there's now a separate tab just for specifying character and string
delimiters. (This might be overkill, but there are various plausible
scenarios that make use of it.)
The delimiters for on-screen display of strings can now be
configured.
High ASCII and other encodings will be noted in the operand field,
not the opcode, so we no longer need these.
This removes the six input fields from the Pseudo-Op tab of app
settings. Values were stored as a serialized class in settings,
which generally works correctly as far as forward/backward
compatibility goes, so no worries there.
This also adds four "delimiter pattern" fields to the Code View tab,
allowing the user to customize how encoded strings are marked up
for the code list. The values aren't actually used yet.
Also, fixed an issue where changes to text fields on the Pseudo-Op
tab weren't raising the dirty flag.
SourceGen creates "auto" labels when it finds a reference to an
address that doesn't have a label associated with it. The label for
address $1234 would be "L1234". This change allows the project to
specify alternative label naming conventions, annotating them with
information from the cross-reference data. For example, a subroutine
entry point (i.e. the target of a JSR) would be "S_1234". (The
underscore was added to avoid confusion when an annotation letter
is the same as a hex digit.)
Also, tweaked the way the preferred clipboard line format is stored
in the settings file (was an integer, now an enumeration string).
Rather than have each assembler get its own app config string for
the cross-assembler executable, we now have a collection of per-
assembler config items, of which the executable path name is one
member. The Asm Config tab has an auto-generated pop-up to select
the assembler.
The per-assembler settings block is serialized with the rather
unpleasant JSON-in-JSON approach, but nobody should have to look
at it.
This also adds assembler-specific column widths to the settings
dialog, though they aren't actually used yet.
If the main window was maximized before, maximize it when we
restart.
Changed the preferences to record the width of the right panels,
rather than the splitter distance, which is actually the width of
the middle of the screen.
Seems to work correctly on my non-uniform multi-monitor setup. I
added a check to confirm that the middle of the title bar falls in
the working area of the screen that WinForms thinks we're in, so it
shouldn't be possible to "lose" a window off the edge by dragging
it or by changing screen resolutions.