The analyzer sometimes runs into things that don't seem right, like
hidden labels or references to non-existent symbols, but has no way
to report them. This adds a problem viewer.
I'm not quite ready to turn this into a real feature, so for now it's
a free-floating window accessed from the debug menu.
Also, updated some documentation.
Split "edit local variable table" into "create" and "edit prior".
The motivation is to allow the user to make changes to the most
recently defined table without having to go search for it. Having
table creation be an explicit action, rather than something that
just happens if you edit a table that isn't there, feels reasonable.
Show table offset in LV table edit dialog, so if you really want
to go find it there's a (clumsy) way to do so.
Increased the maximum width of a variable from 4 to 8. (This is
entirely arbitrary.)
Also, removed "include symbol table" from export dialog. You can
exclude the table by removing it from the template, which right
now you'd need to do anyway to get rid of the H2 header and other
framing. To make this work correctly as an option we'd need to
parse the "div" in the template file and strip the whole section,
or split the template into multiple parts that get included as
needed. Not worth doing the work until we're sure it matters.
Updated the manual, and changed tutorial #2 to use local variables
for pointers.
If the symbol text box isn't empty, use the string as the initial
value for the Label when creating a new project property.
Fixed a crash when editing a project property.
Implemented local variable editing. Operands that have a local
variable reference, or are eligible to have one, can now be edited
directly from the instruction operand edit dialog.
Also, updated the code list double-click handler so that, if you
double-click on the opcode of an instruction that uses a local
variable reference, the selection and view will jump to the place
where that variable was defined.
Also, tweaked the way the References window refers to references
to an address that didn't use a symbol at that address. Updated
the explanation in the manual, which was a bit confusing.
Also, fixed some odds and ends in the manual.
Also, fixed a nasty infinite recursion bug (issue #47).
SourceGen creates "auto" labels when it finds a reference to an
address that doesn't have a label associated with it. The label for
address $1234 would be "L1234". This change allows the project to
specify alternative label naming conventions, annotating them with
information from the cross-reference data. For example, a subroutine
entry point (i.e. the target of a JSR) would be "S_1234". (The
underscore was added to avoid confusion when an annotation letter
is the same as a hex digit.)
Also, tweaked the way the preferred clipboard line format is stored
in the settings file (was an integer, now an enumeration string).
In the cross-reference table we now indicate whether the reference
source is doing a read, write, read-modify-write, branch, subroutine
call, is just referencing the address, or is part of the data.
We were using \u23e9, BLACK RIGHT-POINTING DOUBLE TRIANGLE, but
neither Win7 SP1 nor Linux was able to display the glyph. It also
gets all puffy in web browsers. We now use \u25bc, BLACK
DOWN-POINTING TRIANGLE, which seems to work everywhere. It also
feels more appropriate, because it appears next to the "containing"
opcode, with the embedded instruction appearing on the following
line.
Once upon a time, symbol files and extension scripts could only be
defined in the RuntimeData directory, so having the documentation
there made sense. Since both of these things can now be defined in
project directories, the documentation belongs in the manual.
(issue #27)
The instruction operand editor and data operand editor are very
different, but there's no need to impose that distinction on the
user. They want to edit the operand either way. We now provide a
single "edit operand" menu item, and open the appropriate dialog
based on what they have selected.
This uses Ctrl+O as the keyboard shortcut, stealing it from
File > Open.
(issue #11)
Two changes:
(1) Code and data hints are now only applied to the first byte on
each selected line. This allows you to slap a code hint on a
string without lighting up the whole string. Inline-data hints
and hint removal work as before.
(2) Added a menu item (with Ctrl+D as shortcut) to toggle the state
of the uncategorized data analyzer. This makes it easy to turn
off the feature that put the code into a string in the first
place.
Don't enable OK unless at least one address is valid.
Don't apply code hints unless asked.
Rename a couple of things for clarity.
Add documentation to manual.
(issue #10)