Project symbol address values are now limited to positive 24-bit
integers, just as they are for platform symbols. Constants may
still be 32-bit values.
While disassembling some code I found that I wanted the ROM entry
points, but the zero page usage was significantly different and the
ROM labels were distracting. Splitting the symbol file in two was
a possibility, but I'm afraid this will lead to a very large
collection of very small files, and we'll lose any sense of relation
between the ROM entry points and the ZP addresses used to pass
arguments.
Platform symbols have the lowest priority when resolving by address,
but using that to hide the unwanted labels requires creating project
symbols or local variables for things that you might not know what
they do yet. It's possible to hide a platform symbol by adding
another symbol with the same label and an invalid value.
This change formalizes and extends the "hiding" of platform symbols
to full erasure, so that they don't clutter up the symbol table.
This also tightens up the platform symbol parser to only accept
values in the range 0 <= value <= 0x00ffffff (24-bit positive
integers).
An "F8-ROM-nozp" symbol file is now part of the standard set. A
project can include that to erase the zero-page definitions.
(I'm not entirely convinced this is the right approach, so I'm not
doing this treatment on other symbol files... consider this an
experiment. Another approach would be some sort of conditional
inclusion, or perhaps erase-by-tag, but that requires some UI work
in the app to define what you want included or excluded.)
If we detect a problem that requires intervention during loading,
e.g. we find unknown elements because we're loading a file created
by a newer version, default to read-only mode.
Read only mode (1) refuses to apply changes, (2) refuses to add
changes to the undo/redo list, and (3) disables Save/SaveAs. The
mode is indicated in the title bar.
Also, flipped the order of items in the title bar so that "6502bench
SourceGen" comes last. This allows you to read the project name in
short window title snippets. (Visual Studio, Notepad, and others
do it this way as well.)
Sometimes code relocates a few bits of itself but not others. We
don't currently have a way to say, "go back to where we would have
been". As a cheap alternative, we now show the "load address", i.e.
where we'd be if there were no address map entries after the first.
The "affected flags" constants were incorrect for BIT, BRK, COP,
RTI, XCE, and the undocmented instructions ANE, DCP, and SAX. The
constants are used for the changed-flag summary shown in the info
window and the instruction chart.
Of greater import: the status flag updater for BIT was incorrectly
marking N/V/C as indeterminate instead of N/V/Z. The undocmented
instructions ANE, DCP, and SAX were also incorrect.
The cycle counts shown in line comments are computed correctly, but
the counts shown in the info window and instruction chart were
displaying the full set of modifiers, ignoring the CPU type. That's
okay for the info window, which spells the modifiers out, though
it'd be better if the bits were explicitly marked as being applicable
to the current CPU or a different one.
Mark the "info" window as read-only.
When the project closes, clear the contents of the Symbols and
Notes windows.
Clarify some Apple II I/O definitions.
This adds a window that displays all of the instructions for a
given CPU in a summary grid. Undocumented instructions are
included, but shown in grey italics.
Also, tweaked AppSettings to not mark itself as dirty if a "set"
operation doesn't actually change anything.
Implemented show/hide mechanic, using a button on the right side of
the status bar to show status and to trigger un-hide.
Also, show I/O direction in project symbols editor list.
Created a Navigate menu, and put the menu items for Find and Go To
in it. Added menu items for nav-forward and nav-backward, which
until now were only available as toolbar buttons.
Sometimes there's a bunch of junk in the binary that isn't used for
anything. Often it's there to make things line up at the start of
a page boundary.
This adds a ".junk" directive that tells the disassembler that it
can safely disregard the contents of a region. If the region ends
on a power-of-two boundary, an alignment value can be specified.
The assembly source generators will output an alignment directive
when possible, a .fill directive when appropriate, and a .dense
directive when all else fails. Because we're required to regenerate
the original data file, it's not always possible to avoid generating
a hex dump.
We were failing to update properly when a label changed if the label
was one that a plugin cared about. The problem is that a label
add/remove operation skips the code analysis, and a label edit skips
everything but the display update. Plugins only run during the code
analysis pass, so changes weren't being reflected in the display
list until something caused it to refresh.
The solution is to ask the plugin if the label being changed is one
that it cares about. This allows the plugin to use the same
wildcard-match logic that it uses elsewhere.
For efficiency, and to reduce clutter in plugins that don't care
about symbols, a new interface class has been created to handle the
"here are the symbols" call and the "do you care about this label"
call.
The program in Examples/Scripts has been updated to show a very
simple single-call plugin and a slightly more complex multi-call
plugin.
Most of SourceGen uses standard WPF controls, which get their default
style from the system theme. The main disassembly list uses a
custom style, and always looks like the Windows default theme.
Some people greatly prefer white text on a black background, so we
now provide a way to get that. This also requires muting the colors
used for Notes, since those were chosen to contrast with black text.
This does not affect anything other than the ListView used for
code, because everything else can be set through the Windows
"personalization" interface. We might want to change the way the
Notes window looks though, to avoid having glowing bookmarks on
the side.
The last two tabs in the Edit App Settings dialog have "quick set"
buttons configure all fields for a particular assembler, or reset
them to default values. The previous UI was a little annoying,
because you had to pick something from the combo box and then hit
"set" to push the change. It was also confusing, because if you
came back later the combo box was just set to the first entry, not
the thing you picked last.
Now, picking an entry from the combo box immediately updates all
fields. The combo box selection is set to reflect the actual
contents (so if you set everything just right, the combo box will
change to a specific assembler). If nothing matches, a special
entry labeled "Custom" is selected.
Also, rearranged the tutorial sections in the manual so the
address table formatting comes last, and appears in the local TOC.
The Find box now has forward/backward radio buttons. Find Next
searches forward, and Find Previous searches backward, regardless
of the direction of the initial search.
The standard key sequence for "find previous" is Shift+F3. The WPF
ListView has some weird logic that does something like: if you hit
a key, and the selection changes, and the shift key was held down,
then you must have meant to select a range. So Shift+F3 often (but
not always) selects a range. I think this might be fixable if I can
figure out how ListView keeps track of the current keyboard
navigation position (which is not the same as the selection). For
now I'm working around the problem by using Ctrl+F3 to search.
Yay WPF.
Early data sheets listed BRK as one byte, but RTI after a BRK skips
the following byte, effectively making BRK a 2-byte instruction.
Sometimes, such as when diassembling Apple /// SOS code, it's handy
to treat it that way explicitly.
This change makes two-byte BRKs optional, controlled by a checkbox
in the project settings. In the system definitions it defaults to
true for Apple ///, false for all others.
ACME doesn't allow BRK to have an arg, and cc65 only allows it for
65816 code (?), so it's emitted as a hex blob for those assemblers.
Anyone wishing to target those assemblers should stick to 1-byte mode.
Extension scripts have to switch between formatting one byte of
inline data and formatting an instruction with a one-byte operand.
A helper function has been added to the plugin Util class.
To get some regression test coverage, 2022-extension-scripts has
been configured to use two-byte BRK.
Also, added/corrected some SOS constants.
See also issue #44.
The "add platform symbol file" and "add extension script" buttons
create a file dialog with the initial directory set to the
RuntimeData directory inside the SourceGen installation directory.
This is great if you're trying to add a file from the platform
definitions, but annoying if you're trying to add it from the
project directory.
It's really convenient to not have to hunt around though, so now
there are two buttons: one for platform, one for project. The
latter is disabled if the project is new and hasn't been saved yet.
Extension scripts (a/k/a "plugins") can now apply any data format
supported by FormatDescriptor to inline data. In particular, it can
now handle variable-length inline strings. The code analyzer
verifies the string structure (e.g. null-terminated strings have
exactly one null byte, at the very end).
Added PluginException to carry an exception back to the plugin code,
for occasions when they're doing something so wrong that we just
want to smack them.
Added test 2022-extension-scripts to exercise the feature.
Handle situation where a symbol wraps around a bank. Updated
2021-external-symbols for that, and to test the behavior when file
data and an external symbol overlap.
The bank-wrap test turned up a bug in Merlin 32. A workaround has
been added.
Updated documentation to explain widths.
Change + save + undo + change was being treated as non-dirty.
Added link to "export" feature to documentation TOC.
Added keyboard shortcut for high part in data operand editor.
Corrected various things in the tutorial.
HTML output should have had double quotes around internal anchors.
(Chrome and Edge didn't complain, but the w3c validator wasn't
happy.)
Made the text areas in the load-time problem report dialogs
scrollable.
Updated the manual.
The analyzer sometimes runs into things that don't seem right, like
hidden labels or references to non-existent symbols, but has no way
to report them. This adds a problem viewer.
I'm not quite ready to turn this into a real feature, so for now it's
a free-floating window accessed from the debug menu.
Also, updated some documentation.
Most assemblers end local label scope when a global label is
encountered. cc65 takes this one step further by ending local label
scope when constants or variables are defined. So, if we have a
variable table with a nonzero number of entries, we want to create
a fake global label at that point to end the scope.
Merlin 32 won't let you write " LDA #',' ". For some reason the
comma causes an error. IGenerator now has a "tweak operand format"
interface that lets us fix that.
Split "edit local variable table" into "create" and "edit prior".
The motivation is to allow the user to make changes to the most
recently defined table without having to go search for it. Having
table creation be an explicit action, rather than something that
just happens if you edit a table that isn't there, feels reasonable.
Show table offset in LV table edit dialog, so if you really want
to go find it there's a (clumsy) way to do so.
Increased the maximum width of a variable from 4 to 8. (This is
entirely arbitrary.)
We weren't escaping '<', '>', and '&', which caused browsers to get
very confused. Browsers seem to prefer <PRE> to <CODE> for long
blocks of text, so switch to that.
Also, added support for putting long labels on their own lines in
the HTML output.
Also, fixed some unescaped angle brackets in the manual.
Also, tweaked the edit instruction operand a bit more.
It's possible to define multiple project symbols with the same
address. The way to resolve the ambiguity is to explicitly
reference the desired symbol from the operand. This was the
default behavior of the "create project symbol" shortcut in the
previous version.
It's rarely necessary, and it can get ugly if you rename a project
symbol, because we don't refactor operands in that case.
Also, removed "include symbol table" from export dialog. You can
exclude the table by removing it from the template, which right
now you'd need to do anyway to get rid of the H2 header and other
framing. To make this work correctly as an option we'd need to
parse the "div" in the template file and strip the whole section,
or split the template into multiple parts that get included as
needed. Not worth doing the work until we're sure it matters.
Updated the manual, and changed tutorial #2 to use local variables
for pointers.
If the symbol text box isn't empty, use the string as the initial
value for the Label when creating a new project property.
Fixed a crash when editing a project property.
Implemented local variable editing. Operands that have a local
variable reference, or are eligible to have one, can now be edited
directly from the instruction operand edit dialog.
Also, updated the code list double-click handler so that, if you
double-click on the opcode of an instruction that uses a local
variable reference, the selection and view will jump to the place
where that variable was defined.
Also, tweaked the way the References window refers to references
to an address that didn't use a symbol at that address. Updated
the explanation in the manual, which was a bit confusing.
Also, fixed some odds and ends in the manual.
Also, fixed a nasty infinite recursion bug (issue #47).
The code that checked to see if a data target was inside a data
operand wasn't going all the way back to the start of the file.
It was also failing to stop when it should, wasting time.
The anattrib validation method has code that avoids a false-positive
on certain complex embedded instruction arrangements. This was also
preventing it from seeing a transition from a data area to the
middle of an instruction (caused by issue #45).
Previously, we used the default character encoding from the project
properties to determine how strings and character constants in the
entire source file should be encoded. Now we switch between
encodings as needed. The default character encoding is no longer
relevant.
High ASCII is now an actual encoding, rather than acting like ASCII
that sometimes doesn't work. Because we can do high ASCII character
operands with "| $80", we don't output a .enc to switch from ASCII
to high ASCII unless we need to generate a string. (If we're
already in high ASCII mode, the "| $80" isn't required but won't
hurt anything.)
We now do a scan up front to see if ASCII or high ASCII is needed,
and only output the .cdefs for the encodings that are actually used.
The only gap in the matrix is high ASCII DCI strings -- the ".shift"
pseudo-op rejects text if the string doesn't start with the high
bit clear.
I didn't think it made sense, but I found something that used it,
so apparently it's a thing. This updates the operand editor to
let you choose PETSCII+DCI, and updates the assemblers to handle
it correctly (really just 64tass, since the others either don't
have a DCI directive or don't deal with PETSCII at all).
Changed the char-encoding sample from "bad dcI" to "pet dcI", and
updated the documentation.
The documentation for 64tass says you're required to pass "--ascii"
when the source file is ASCII (as opposed to PETSCII). We were
ignoring this, but it turns out that everything works a bit better
if we don't.
So we now pass "--ascii" on the command line, and add a two-line
character encoding definition to every file that is generated with
ASCII as the default encoding. The sg_petscii and sg_screen
encodings go away, as PETSCII is now the default, and we can use the
built-in "screen" encoding.
The plugin objects are MarshalByRefObject stubs, which means they
don't actually implement the interfaces we're checking for. There's
some additional overhead to do the interface check. We can avoid
it by doing the interface queries during initialization, and just
checking some bit flags later on.
Also, in the extension script info window, show a list of
implemented interfaces.
During a discussion with the cc65 developers, I became convinced that
generating "MVN $01,$02" is wrong, and "MVN #$01,#$02" is correct.
64tass, cc65, and Merlin 32 all accept this syntax; only ACME does
not. Operands without a leading '#' should be treated as 24-bit
values, and have the bank byte extracted.
This change updates the on-screen display and assembled output to
include the '#'. The ACME generator uses a Quirk to suppress the
hash mark. (It doesn't currently accept values larger than 8 bits,
so there's no ambiguity.)
There's no easy way to make non-zero-bank 65816 code work, so I'm
punting and just generating a whole-file hex dump for those. This
renders tests 2007 and 2009 useless, so I'm hesitant to claim that
ACME support is fully functional.