If an address map entry wraps around the end of a bank, add a note
to the message log. This is Error level, since some assemblers
will refuse to handle it.
It's too easy to hit Escape after making a bunch of changes, so
now we ask for confirmation.
(Might make sense to make this strictly an Esc guard, and not
pester the user if they actually hit the Cancel button or close
box. I'm not convinced though; Esc+Enter isn't terrible.)
Some style guides say you should only put one space between
sentences, but I and many others still put two. The line-folding
code was only eating one of them when they straddled the end of the
line, which looked a little funny because the following line was
indented by one space.
This tweaks the code to eat both spaces. Regression test updated.
Also, nudge some UI elements so they line up.
Jumps to the first offset associated with the change at the top of
the Undo stack. We generally jump to the code/data offset, not the
specific line affected. It's possible to do better (and we do, for
Notes), but probably not worthwhile.
As noted in issue #52, the side panels can't be resized once the
ListView gets focus. The root of the problem is a workaround for a
selection problem that involves catching the Item Container
Generator's Status Changed event, and setting an item's focus. It
appears that changing the size of the ListView causes the
StatusChanged event to fire, which cause the handler to grab the
focus, which causes the splitters to stop moving after one step.
This change adds a workaround that prevents the original workaround
from doing anything while a splitter is in the process of being
dragged. It doesn't solve all problems -- you can't move the
splitters more than one step with the keyboard -- but it allows them
to be dragged around with the mouse.
There's got to be a better way to deal with this.
Copied the extension script tutorial files out of the Scripts
directory and into the Tutorial directory. This makes more sense,
and makes it possible to expand the script sample without altering
the tutorial.
Reverted the Scripts sample to be an actual sample, rather than a
tutorial.
Renumbered the last two tutorials and added them to the ToC. This
gives them actual numbers rather than treating them as add-ons to
the advanced tutorial.
Moved the source files for the tutorial binaries into a subdirectory
to reduce clutter.
This does mean we have two separate copies of the inline string
sample plugins, but that's an artifact of our attempts at security.
The code that found a nearby data target for an instruction operand
was searching backward but not forward. We now take one step
forward, so that "LDA TABLE-1,Y" fills in automatically.
This altered 2008-address-changes, which had just this situation.
It didn't alter 2010-target-adjustment, but the existing tests were
insufficient and have been improved.
The fix for Shift+F3 required briefly switching the code list view
to single-select mode. Unfortunately, while in that mode the
control throws an exception if you touch SelectedItems (plural)
rather than SelectedItem (singular), and in an unusual case the
selection-changed event handler was doing just that.
If a local variable table gets buried, it won't appear in the code
list, so most things ignore it. Unfortunately, the code that adds
new entries and edits tables was finding them, which was causing
variable definitions to appear to fall into a black hole.
This is addressed in two ways. First, we now add a message to the
log when a hidden table is noticed. Second, the code that finds
the nearest prior table now keeps track of hidden vs. not hidden.
If a non-hidden table is available, that is returned. If the only
option is a hidden table, we will return that, because the callers
have already assumed that a table exists by virtue of its presence
in the LvTable list.
Project symbol address values are now limited to positive 24-bit
integers, just as they are for platform symbols. Constants may
still be 32-bit values.
While disassembling some code I found that I wanted the ROM entry
points, but the zero page usage was significantly different and the
ROM labels were distracting. Splitting the symbol file in two was
a possibility, but I'm afraid this will lead to a very large
collection of very small files, and we'll lose any sense of relation
between the ROM entry points and the ZP addresses used to pass
arguments.
Platform symbols have the lowest priority when resolving by address,
but using that to hide the unwanted labels requires creating project
symbols or local variables for things that you might not know what
they do yet. It's possible to hide a platform symbol by adding
another symbol with the same label and an invalid value.
This change formalizes and extends the "hiding" of platform symbols
to full erasure, so that they don't clutter up the symbol table.
This also tightens up the platform symbol parser to only accept
values in the range 0 <= value <= 0x00ffffff (24-bit positive
integers).
An "F8-ROM-nozp" symbol file is now part of the standard set. A
project can include that to erase the zero-page definitions.
(I'm not entirely convinced this is the right approach, so I'm not
doing this treatment on other symbol files... consider this an
experiment. Another approach would be some sort of conditional
inclusion, or perhaps erase-by-tag, but that requires some UI work
in the app to define what you want included or excluded.)
- Allow user to "unnecessarily" set an address override. This is
a handy thing to do when dealing with code that does a lot of
relocations.
- Moved "save needed" text to the end of the title string.
- Updated F8-ROM syms.
- Added ProDOS 8 error code constants
If we detect a problem that requires intervention during loading,
e.g. we find unknown elements because we're loading a file created
by a newer version, default to read-only mode.
Read only mode (1) refuses to apply changes, (2) refuses to add
changes to the undo/redo list, and (3) disables Save/SaveAs. The
mode is indicated in the title bar.
Also, flipped the order of items in the title bar so that "6502bench
SourceGen" comes last. This allows you to read the project name in
short window title snippets. (Visual Studio, Notepad, and others
do it this way as well.)
While adding a message log entry for failing alignment directives,
I noticed that the assembler source generator's test for valid
alignment was allowing some bad alignment values through.
I'm holding off on reporting the message to the log because not all
format changes cause a data-reanalysis, which means the log entry
doesn't always appear and disappear when it should. If we decide
this is an important message we can add a scan for "softer" errors.
In the assembler output, add a blank line between the constants
and addresses in the long list of equates.
The earlier change that corrected the BIT instruction caused test
2009-branches-and-banks to fail, because it was relying on the idea
that BIT made the carry flag indeterminate. Changing a BCC to a
BVS restored the desired behavior.
Not a huge improvement, but things are slightly more organized, and
there's a splash of color in the form of a border around the text
describing the format of code and data lines.
Added an "IsConstant" property to Symbol.
Sometimes code relocates a few bits of itself but not others. We
don't currently have a way to say, "go back to where we would have
been". As a cheap alternative, we now show the "load address", i.e.
where we'd be if there were no address map entries after the first.
The "affected flags" constants were incorrect for BIT, BRK, COP,
RTI, XCE, and the undocmented instructions ANE, DCP, and SAX. The
constants are used for the changed-flag summary shown in the info
window and the instruction chart.
Of greater import: the status flag updater for BIT was incorrectly
marking N/V/C as indeterminate instead of N/V/Z. The undocmented
instructions ANE, DCP, and SAX were also incorrect.
The cycle counts shown in line comments are computed correctly, but
the counts shown in the info window and instruction chart were
displaying the full set of modifiers, ignoring the CPU type. That's
okay for the info window, which spells the modifiers out, though
it'd be better if the bits were explicitly marked as being applicable
to the current CPU or a different one.
Mark the "info" window as read-only.
When the project closes, clear the contents of the Symbols and
Notes windows.
Clarify some Apple II I/O definitions.
This adds a window that displays all of the instructions for a
given CPU in a summary grid. Undocumented instructions are
included, but shown in grey italics.
Also, tweaked AppSettings to not mark itself as dirty if a "set"
operation doesn't actually change anything.
Implemented show/hide mechanic, using a button on the right side of
the status bar to show status and to trigger un-hide.
Also, show I/O direction in project symbols editor list.
This converts the "problem list viewer" tool to a grid that appears
below the code list view when non-empty. Not all messages are
problems, so it's being renamed to "message list".
Created a Navigate menu, and put the menu items for Find and Go To
in it. Added menu items for nav-forward and nav-backward, which
until now were only available as toolbar buttons.
This began with a change to support "BRK <operand>" in cc65. The
assembler only supports this for 65816 projects, so we detect that
and enable it when available.
While fiddling with some test code an assertion fired. This
revealed a minor issue in the code analyzer: when overwriting inline
data with instructions, we weren't resetting the format descriptor.
The code that exercises it, which requires two-byte BRKs and an
inline BRK handler in an extension script, has been added to test
2022-extension-scripts.
The new regression test revealed a flaw in the 64tass code
generator's character encoding scanner that caused it to hang.
Fixed.
Sometimes there's a bunch of junk in the binary that isn't used for
anything. Often it's there to make things line up at the start of
a page boundary.
This adds a ".junk" directive that tells the disassembler that it
can safely disregard the contents of a region. If the region ends
on a power-of-two boundary, an alignment value can be specified.
The assembly source generators will output an alignment directive
when possible, a .fill directive when appropriate, and a .dense
directive when all else fails. Because we're required to regenerate
the original data file, it's not always possible to avoid generating
a hex dump.
Sort of silly to have every handler immediately pull the operand out
of the file data. (This is arguably less efficient, since we now
have to serialize the argument across the AppDomain boundary, but