1
0
mirror of https://github.com/fadden/6502bench.git synced 2024-12-12 05:31:04 +00:00
Commit Graph

24 Commits

Author SHA1 Message Date
Andy McFadden
13dca8b78c More tweaks to def sym editing
If you edit an existing symbol, the "is the label unique" test will
always false-positive match itself, so we have to explicitly handle
that case.  Dialogs like Edit Instruction Operand make things a bit
more complicated because they don't flush results to the symbol
table immediately, which means the symbol we pass into the Edit Def
Symbol dialog to edit isn't necessarily the one we need to exclude
from the label uniqueness test.

The dialog was using the initial value as both "original" and
"initial", which caused some issues.  We now pass both values in.

Also, removed some dead code identified by VS.
2022-03-02 08:13:46 -08:00
Andy McFadden
b60dc4fee4 Add W65C02S support, part 1
We were claiming W65C02S, but it turns out that CPU has the Rockwell
extensions and the STP/WAI instructions.  We need to change existing
references to be "WDC 65C02", and add a new CPU definition for the
actual W65C02S chip.

This adds the new CPU definition, the instruction definitions for
the Rockwell extensions, and updates the selectors in project properties
and the instruction chart tool.

This change shouldn't affect any existing projects.  Still more to do
before W65C02 works though, mostly because the Rockwell instructions
introduced a new two-argument address mode that has to be handled in
various places.
2020-10-10 15:46:34 -07:00
Andy McFadden
1e7a6620e0 Make project properties window resizable
Useful for the project symbols tab.  The size is retained for the
current session, but resets when the program exits.
2020-07-24 17:14:15 -07:00
Andy McFadden
0929077fda Data Bank Register management, part 4
Implemented "smart" PLB handling.  If we see PHK/PLB, or 8-bit
LDA imm/PHA/PLB, we create a data bank change item.  The feature
can be disabled with a project property.
2020-07-09 19:42:31 -07:00
Andy McFadden
d58b747571 Use relocation data to format instruction operands
This was a relatively lightweight change to confirm the usefulness
of relocation data.  The results were very positive.

The relatively superficial integration of the data into the data
analysis process causes some problems, e.g. the cross-reference table
entries show an offset because the code analyzer's computed operand
offset doesn't match the value of the label.  The feature should be
considered experimental

The feature can be enabled or disabled with a project property.  The
results were sufficiently useful and non-annoying to make the setting
enabled by default.
2020-07-03 17:58:41 -07:00
Andy McFadden
89413d11e4 Add file concatenation tool
Select a list of files and save it.  File lengths and CRCs are
shown for reference.
2019-12-28 17:22:19 -08:00
Andy McFadden
0b0944e0fc Add F6 as a shortcut for the Project Symbols editor
Goes directly to the second tab of Edit Project Properties.  This is
not represented in the menu system.
2019-12-13 13:05:29 -08:00
Andy McFadden
5dd7576529 Label rework, part 2
Continue development of non-unique labels.  The actual labels are
still unique, because we append a uniquifier tag, which gets added
and removed behind the scenes.  We're currently using the six-digit
hex file offset because this is only used for internal address
symbols.

The label editor and most of the formatters have been updated.  We
can't yet assemble code that includes non-unique labels, but older
stuff hasn't been broken.

This removes the "disable label localization" property, since that's
fundamentally incompatible with what we're doing, and adds a non-
unique label prefix setting so you can put '@' or ':' in front of
your should-be-local labels.

Also, fixed a field name typo.
2019-11-12 17:44:51 -08:00
Andy McFadden
4d079c8d14 Label rework, part 1
This adds the concept of label annotations.  The primary driver of
the feature is the desire to note that sometimes you know what a
thing is, but sometimes you're just taking an educated guess.
Instead of writing "high_score_maybe", you can now write "high_score?",
which is more compact and consistent.  The annotations are stripped
off when generating source code, making them similar to Notes.

I also created a "Generated" annotation for the labels that are
synthesized by the address table formatter, but don't modify the
label for them, because there's not much need to remind the user
that "T1234" was generated by algorithm.

This also lays some of the groundwork for non-unique labels.
2019-11-08 21:02:15 -08:00
Andy McFadden
6a8d6950e5 Add change discard confirmation to project properties editor
It's too easy to hit Escape after making a bunch of changes, so
now we ask for confirmation.

(Might make sense to make this strictly an Esc guard, and not
pester the user if they actually hit the Cancel button or close
box.  I'm not convinced though; Esc+Enter isn't terrible.)
2019-11-04 17:41:33 -08:00
Andy McFadden
630f7f0f87 Improve the "info" panel
Not a huge improvement, but things are slightly more organized, and
there's a splash of color in the form of a border around the text
describing the format of code and data lines.

Added an "IsConstant" property to Symbol.
2019-10-22 21:27:49 -07:00
Andy McFadden
a4f1de1238 Add message list, part 2 (of 2)
Implemented show/hide mechanic, using a button on the right side of
the status bar to show status and to trigger un-hide.

Also, show I/O direction in project symbols editor list.
2019-10-20 18:02:23 -07:00
Andy McFadden
dfd5bcab1b Optionally treat BRKs as two-byte instructions
Early data sheets listed BRK as one byte, but RTI after a BRK skips
the following byte, effectively making BRK a 2-byte instruction.
Sometimes, such as when diassembling Apple /// SOS code, it's handy
to treat it that way explicitly.

This change makes two-byte BRKs optional, controlled by a checkbox
in the project settings.  In the system definitions it defaults to
true for Apple ///, false for all others.

ACME doesn't allow BRK to have an arg, and cc65 only allows it for
65816 code (?), so it's emitted as a hex blob for those assemblers.
Anyone wishing to target those assemblers should stick to 1-byte mode.

Extension scripts have to switch between formatting one byte of
inline data and formatting an instruction with a one-byte operand.
A helper function has been added to the plugin Util class.

To get some regression test coverage, 2022-extension-scripts has
been configured to use two-byte BRK.

Also, added/corrected some SOS constants.

See also issue #44.
2019-10-09 14:55:56 -07:00
Andy McFadden
b8e11215fa Add separate button for adding symbols+scripts from project
The "add platform symbol file" and "add extension script" buttons
create a file dialog with the initial directory set to the
RuntimeData directory inside the SourceGen installation directory.
This is great if you're trying to add a file from the platform
definitions, but annoying if you're trying to add it from the
project directory.

It's really convenient to not have to hunt around though, so now
there are two buttons: one for platform, one for project.  The
latter is disabled if the project is new and hasn't been saved yet.
2019-10-09 13:24:09 -07:00
Andy McFadden
14150af004 Allow explicit widths in project/platform symbols, part 2
Added a Width column to the list in the project symbol editor.

Changed the local variable table editor and the project symbol editor
to use DataGrid instead of ListView.  This gets us easy sorting on
arbitrary columns.  The previous code was reloading the display list
after every change; now we just add/edit/remove individual items,
which helps keep the list position and selection stable.
2019-10-01 19:11:54 -07:00
Andy McFadden
2a41d70e04 Allow explicit widths in project/platform symbols, part 1
The ability to give explicit widths to local variables worked out
pretty well, so we're going to try adding the same thing to project
and platform symbols.

The first step is to allow widths to be specified in platform files,
and set with the project symbol editor.  The DefSymbol editor is
also used for local variables, so a bit of dancing is required.
For platform/project symbols the width is optional, and is totally
ignored for constants.  (For variables, constants are used for the
StackRel args, so the width is meaningful and required.)

We also now show the symbol's type (address or constant) and width
in the listing.  This gets really distracting when overused, so we
only show it when the width is explicitly set.  The default width
is 1, which most things will be, so users can make an aesthetic
choice there.  (The place where widths make very little sense is when
the symbol represents a code entry point, rather than a data item.)

The maximum width of a local variable is now 256, but it's not
allowed to overlap with other variables or run of the end of the
direct page.  The maximum width of a platform/project symbol is
65536, with bank-wrap behavior TBD.

The local variable table editor now refers to stack-relative
constants as such, rather than simply "constant", to make it clear
that it's not just defining an 8-bit constant.

Widths have been added to a handful of Apple II platform defs.
2019-10-01 16:00:08 -07:00
Andy McFadden
6bc491885a Minor UI tweaks
Typing a long comment in the project symbol editor caused the
window to expand, which wasn't intended.  Use the mono font in
the comment editor.  Set the focus to the OK button after creating
or editing a project property.  Show constant vs. address in the
info panel when an EQU directive is selected.
2019-09-18 18:11:48 -07:00
Andy McFadden
e8ae534879 Instruction operand editor rework, part 2
Implemented local variable editing.  Operands that have a local
variable reference, or are eligible to have one, can now be edited
directly from the instruction operand edit dialog.

Also, updated the code list double-click handler so that, if you
double-click on the opcode of an instruction that uses a local
variable reference, the selection and view will jump to the place
where that variable was defined.

Also, tweaked the way the References window refers to references
to an address that didn't use a symbol at that address.  Updated
the explanation in the manual, which was a bit confusing.

Also, fixed some odds and ends in the manual.

Also, fixed a nasty infinite recursion bug (issue #47).
2019-09-07 20:56:43 -07:00
Andy McFadden
431ad94d95 Make "smart" PLP handling optional
We try to be clever with PHP/PLP, but sometimes we get it wrong.  If
we get it wrong a lot, we want to turn it off.  Now we can.
2019-09-02 15:57:59 -07:00
Andy McFadden
0eeb36f59a Add LocalVariableTable list to project
This involved adding a list to the DisasmProject, creating a new
UndoableChange type, and writing the project file serialization
code.  While doing the latter I realized that the new Width field
was redundant with the FormatDescriptor Length field, and removed it.

I added a placeholder line type, but we're not yet showing the
table in the display list.  (To edit the tables you just have to
know where they are.)
2019-08-26 16:58:53 -07:00
Andy McFadden
1cc9d2bd70 Update editors to work with local variables
The table editor is now editing the table, and the DefSymbol editor
now asks for the Width data when editing a local var.

This also moves EditDefSymbol closer to proper WPF style, with
bound properties for the input fields.

No changes yet to serialization or analysis.
2019-08-25 17:25:15 -07:00
Andy McFadden
7bbe5692bd Add C64 encodings to instruction and data operand editors
Both dialogs got a couple extra radio buttons for selection of
single character operands.  The data operand editor got a combo box
that lets you specify how it scans for viable strings.

Various string scanning methods were made more generic.  This got a
little strange with auto-detection of low/high ASCII, but that was
mostly a matter of keeping the previous code around as a special
case.

Made C64 Screen Code DCI strings a thing that works.
2019-08-15 17:53:12 -07:00
Andy McFadden
d5b53a0795 Add combo box for default text scan mode
It's not quite the same as the character encoding -- sometimes we
want a mix of things -- so it gets its own enum.  The value is
saved to the project file, but not actually used yet.

Also, moved some combo box strings into XAML resources.
2019-08-12 18:01:29 -07:00
Andy McFadden
c64f72d147 Move WPF code from SourceGenWPF to SourceGen 2019-07-20 13:28:37 -07:00