mirror of
https://github.com/fadden/6502bench.git
synced 2024-11-29 10:50:28 +00:00
f51b583d3b
The scripts for tutorial #4 were suffering from bit rot. Did some word-smithing on the tutorials.
867 lines
47 KiB
HTML
867 lines
47 KiB
HTML
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
|
<html xmlns="http://www.w3.org/1999/xhtml">
|
|
|
|
<head>
|
|
<meta content="text/html; charset=utf-8" http-equiv="Content-Type" />
|
|
<meta name="viewport" content="width=device-width, initial-scale=1" />
|
|
<link href="main.css" rel="stylesheet" type="text/css" />
|
|
<title>Tutorials - 6502bench SourceGen</title>
|
|
</head>
|
|
|
|
<body>
|
|
<div id="content">
|
|
<h1>6502bench SourceGen: Tutorials</h1>
|
|
<p><a href="index.html">Back to index</a></p>
|
|
|
|
<p>The tutorials introduce SourceGen and cover some of the basic
|
|
features. They skim lightly over some important concepts, like the
|
|
difference between numeric and symbolic references, so reading the
|
|
manual is recommended.</p>
|
|
|
|
<ul>
|
|
<li><a href="#basic-features">#1: Basic Features</a></li>
|
|
<li><a href="#advanced-features">#2: Advanced Features</a></li>
|
|
<li><a href="#address-tables">#3: Address Table Formatting</a></li>
|
|
<li><a href="#extension-scripts">#4: Extension Scripts</a></li>
|
|
<li><a href="#visualizations">#5: Visualizations</a></li>
|
|
</ul>
|
|
|
|
|
|
<h2><a name="basic-features">Tutorial #1: Basic Features</a></h2>
|
|
|
|
<p>Start by launching SourceGen. The initial screen has a large
|
|
center area with some buttons, and some mostly-empty windows on the sides.
|
|
The buttons are shortcuts for items in the File menu.</p>
|
|
|
|
|
|
<h3>Create the project</h3>
|
|
|
|
<p>Click "Start new project".</p>
|
|
|
|
<p>The New Project window has three parts. The top-left window has a
|
|
tree of known platforms, arranged by manufacturer. The top-right window
|
|
provides some details on whichever platform is selected. The bottom
|
|
window will have some information about the data file, once we choose one.</p>
|
|
<p>Scroll down in the list, and select "Generic 6502". Then click
|
|
"Select File...", navigate to the SourceGen installation directory,
|
|
open the "Examples" folder, then open the "Tutorial" folder. Select the
|
|
file named "Tutorial1", and click "Open".</p>
|
|
<p>The filename now appears in the bottom window, along with an indication
|
|
of the file's size.</p>
|
|
<p>Click "OK" to create the project.</p>
|
|
|
|
|
|
<h3>Getting Around</h3>
|
|
|
|
<p>The first thing we'll do is save the project. Some features create or
|
|
load files from the directory where the project lives, so we want to
|
|
establish that.</p>
|
|
<p>Select File > Save, which will bring up a standard save-file dialog.
|
|
Make sure you're in still in the Examples/Tutorial folder. The default
|
|
project file name is "Tutorial1.dis65", which is what we want, so just
|
|
click "Save".</p>
|
|
|
|
<p>The display is divided into rows, one per line of disassembled code
|
|
or data. This is a standard Windows "list view", so you can select a row
|
|
by left-clicking anywhere in it. Use Ctrl+Click to toggle the selection
|
|
on individual lines, and Shift+Click to select a range of lines. You can
|
|
move the selection around with the up/down arrow keys and PgUp/PgDn. Scroll
|
|
the window with the mouse wheel or by dragging the scroll bar.</p>
|
|
|
|
<p>Each row is divided into nine columns. You can adjust the column
|
|
widths by clicking and dragging the column dividers in the header. The
|
|
columns on the right side of the screen are similar to what you'd find
|
|
in assembly source code: label, opcode, operand, comment. The columns
|
|
on the left are what you'd find in a disassembly (file offset, address,
|
|
raw bytes), plus some information about processor status flags and line
|
|
attributes that may or may not be useful to you. If you find any of
|
|
these distracting, collapse the column.</p>
|
|
|
|
<p>Click on the fourth line down, which has address 1002. The line has
|
|
a label, "L1002", and is performing an indexed load from L1017. Both
|
|
of these labels were automatically generated, and are named for the
|
|
address at which they appear. When you clicked on the line, a few
|
|
things happened:</p>
|
|
<ul>
|
|
<li>The line was highlighted in the system selection color (usually
|
|
blue).</li>
|
|
<li>Address 1017 and label L1017 were highlighted. When you select
|
|
a line with an operand that targets an in-file address, the target
|
|
address is highlighted.</li>
|
|
<li>An entry appeared in the References window. This tells you that the
|
|
only reference to L1002 is a branch from address $100B.</li>
|
|
<li>The Info window filled with a bunch of text that describes the
|
|
line format and some details about the LDA instruction.</li>
|
|
</ul>
|
|
|
|
<p>Click some other lines, such as address $100B and $1014. Note how the
|
|
highlights and contents of other windows change.</p>
|
|
<p>Click on L1002 again, then double-click on the opcode ("LDA"). The
|
|
selection jumps to L1017. When an operand references an in-file address,
|
|
double-clicking on the opcode will take you to it. (Double-clicking on
|
|
the operand itself opens a format editor; more on that later.)</p>
|
|
<p>With line L1017 selected, double-click on the line that appears in the
|
|
References window. Note the selection jumps to L1002. You can immediately
|
|
jump to any reference.</p>
|
|
<p>At the top of the Symbols window on the right side of the screen is a
|
|
row of buttons. Make sure "Auto" and "Addr" are selected. You should see
|
|
three labels in the window (L1002, L1014, L1017). Double-click on "L1014"
|
|
in the Symbols list. The selection jumps to the appropriate line.</p>
|
|
|
|
<p>Select Navigate > Find. Type "hello", and hit Enter. The selection will
|
|
move to address $100E, which is a string that says "hello!". You can use
|
|
Navigate > Find Next to try to find the next occurrence (there isn't one). You
|
|
can search for any text that appears in the rightmost columns (label, opcode,
|
|
operand, comment).</p>
|
|
<p>Select Navigate > Go To. You can enter a label, address, or file offset.
|
|
Enter "100b" to set the selection to the line at address $100B.</p>
|
|
|
|
<p>Near the top-left of the SourceGen window is a set of toolbar icons.
|
|
Click the curly left-pointing arrow, and watch the selection move. Click
|
|
it again. Then click the curly right-arrow a couple of times. Whenever
|
|
you jump around in the file by using the Go To feature, or by double-clicking
|
|
on opcodes or lines in the side windows, the locations are added to a
|
|
navigation history. The arrows let you move forward and backward
|
|
through it.</p>
|
|
|
|
|
|
<h3>Editing</h3>
|
|
|
|
<p>Click the very first line of the file, which is a comment that says
|
|
something like "6502bench SourceGen vX.Y.Z". There are three ways to
|
|
open the comment editor:</p>
|
|
<ol>
|
|
<li>Select Actions > Edit Long Comment from the menu bar.</li>
|
|
<li>Right click, and select Edit Long Comment from the
|
|
pop-up menu. (This menu is exactly the same as the Actions menu.)</li>
|
|
<li>Double-click the comment</li>
|
|
</ol>
|
|
<p>Most things in the code list will respond to a double-click.
|
|
Double-clicking on addresses, flags, labels, operands, and comments will
|
|
open editors for those things. Double-clicking on a value in the "bytes"
|
|
column will open a floating hex dump viewer. This is usually the most
|
|
convenient way to edit something: point and click.</p>
|
|
<p>Double-click the comment to open the editor. Type some words into the
|
|
upper window, and note that a formatted version appears in the bottom
|
|
window. Experiment with the maximum line width and "render in box"
|
|
settings to see what they do. You can hit Enter to create line breaks,
|
|
or let SourceGen wrap lines for you. When you're done, click "OK". (Or
|
|
hit Ctrl+Enter.)</p>
|
|
<p>When the dialog closes, you'll see your new comment in place at the
|
|
top of the file. If you typed enough words, your comment will span
|
|
multiple lines. You can select the comment by selecting any line in it.</p>
|
|
|
|
<p>Click on the comment, then shift-click on L1014. Right-click, and look
|
|
at the menu. Nearly all of the menu items are disabled. Most edit features
|
|
are only enabled when a single instance of a relevant item is selected, so
|
|
for example Edit Long Comment won't be enabled if you have an instruction
|
|
selected.</p>
|
|
|
|
<p>Let's add a note. Click on $100E (the line with "hello!"), then
|
|
select Actions > Edit Note. Type a few words, pick a color, and click "OK"
|
|
(or hit Ctrl+Enter). Your note appears in the code, and also in the
|
|
window on the bottom left. Notes are like long comments, with three key
|
|
differences:</p>
|
|
<ol>
|
|
<li>You can't pick their line width, but you can pick their color.</li>
|
|
<li>They don't appear in generated assembly sources, making them
|
|
useful for leaving notes to yourself as you work.</li>
|
|
<li>They're listed in the Notes window. Double-clicking them jumps
|
|
the selection to the note, making them useful as bookmarks.</li>
|
|
</ol>
|
|
|
|
<p>It's time to do something with the code. If you look at what the code
|
|
does you'll see that it's copying several dozen bytes from $1017
|
|
to $2000, then jumping to $2000. It appears to be relocating the next
|
|
part of the code before
|
|
executing it. We want to let the disassembler know what's going on, so
|
|
select the line at address $1017 and then
|
|
Actions > Set Address. (Or double-click the "1017" in the Addr column.)
|
|
In the Set Address dialog, type "2000", and hit Enter.)</p>
|
|
|
|
<p>Note the way the code list has changed. When you changed the address,
|
|
the "JMP $2000" at L1014 found a home inside the bounds of the file, so
|
|
the code tracer was able to find the instructions there.</p>
|
|
<p>From the menu, select Edit > Undo. Notice how everything reverts to
|
|
the way it was. Now, select Edit > Redo. You can undo any change you
|
|
make to the project. (The undo history is <strong>not</strong> saved in
|
|
the project file, though, so when you exit the program the history is
|
|
lost.)</p>
|
|
<p>Notice that, while the address column has changed, the offset column
|
|
has not. File offsets never change, which is why they're shown here and
|
|
in the References and Notes windows. (They can, however, be distracting,
|
|
so you'll be forgiven if you reduce the offset column width to zero.)</p>
|
|
<p>On the line at address $2000, select Actions > Edit Label, or
|
|
double-click on the label "L2000". Change the label to "MAIN", and hit
|
|
Enter. The label changes on that line, and on the two lines that refer
|
|
to address $2000. (If you're not sure which lines refer to address $2000,
|
|
select line $2000 and look at the References window.)</p>
|
|
<p>On that same line, select Actions > Edit Comment. Type a short
|
|
comment, and hit Enter. Your comment appears in the "comment" column.</p>
|
|
|
|
|
|
<h3>Editing Instruction Operands</h3>
|
|
|
|
<p>Select the line with address $2003 ("CMP #$04"), then
|
|
Actions > Edit Operand. This allows you to pick how you want the
|
|
operand to look. It's currently set to "Default", which for an 8-bit
|
|
immediate argument means it's shown as a hexadecimal value. Click
|
|
"Binary", then "OK". It now appears as a binary value.</p>
|
|
|
|
<p>The operand in the LDA instruction at line $2000 refers to an address
|
|
($3000) that isn't part of the file. We want to create an equate directive to
|
|
give it a name. With the line at $2000 selected, use Actions > Edit Operand,
|
|
or double-click on "$3000". Select the "Symbol" radio button, then type
|
|
"INPUT" in the text box. Click "OK".</p>
|
|
<p>Disappointed? The instruction is unchanged. The problem is that we
|
|
updated the operand to reference a symbol that doesn't exist. This fact
|
|
is noted in a message that appeared at the bottom of the screen. Open the
|
|
operand editor again, but this time click on "Create Project Symbol" at
|
|
the bottom left. Enter "INPUT" in the Label field, and click "OK", then
|
|
click "OK" in the operand editor.</p>
|
|
<p>That's better. The instruction looks the way we wanted it to, and the
|
|
message at the bottom of the window disappeared. If you scroll up to the
|
|
top of the project, you'll see that there's now a ".EQ" line for
|
|
the symbol.</p>
|
|
<p>Operands that refer to in-file locations behave similarly. Select the
|
|
line two down, at address $2005, and Actions > Edit Operand. Enter the
|
|
symbol "IS_OK". (Note you don't actually have to click Symbol first -- if
|
|
you just start typing as soon as the dialog opens, it'll select Symbol
|
|
for you automatically.) Click "OK".</p>
|
|
<p>As before, nothing appears to have happened, but if you were watching
|
|
carefully you would have noticed that the label at $2009 ("L2009") has
|
|
disappeared. This happened because the code at $2005 used to have a
|
|
<i>numeric</i> reference to $2009, and SourceGen automatically created a
|
|
label. However, you changed the code at $2005 to have a <i>symbolic</i>
|
|
reference to a symbol called "IS_OK", and there were no other numeric
|
|
references to $2009, so the auto-label was no longer
|
|
needed. Because IS_OK doesn't exist, the operand at $2005 is just formatted
|
|
as a hexadecimal value. (There's also now a message at the bottom of the
|
|
window telling us this.)</p>
|
|
<p>Let's fix this. Select the line at address $2009, then
|
|
Actions > Edit Label. Enter "IS_OK", and hit Enter. (NOTE: labels are
|
|
case-sensitive, so it needs to match the operand at $2005 exactly.) You'll
|
|
see the new label appear, and the operand at line $2005 will use it.</p>
|
|
|
|
<!--<p>There's an easier way. Select Edit > Undo twice, to get back to the
|
|
state where line $2005 says "BCC L2009", and line $2009 has the label
|
|
L2009. Now double-click on the "BCC" opcode (not operand) at address
|
|
$2005. This moves the selection to $2009. Double-click on the label field,
|
|
and enter "IS_OK". Hit "OK".</p>
|
|
<p>You should now see that both the operand at $2005 and the label at
|
|
$2009 have changed to IS_OK, accomplishing what we wanted to do in a
|
|
single step. The key difference is that we haven't explicitly set a
|
|
format for the BCC operand -- we just defined a label, and SourceGen
|
|
used it automatically.</p>-->
|
|
|
|
<p>There's another way to set a label that is simpler and more convenient.
|
|
Select Edit > Undo twice, to get back to the state where line $2005
|
|
says "BCC L2009", and line $2009 has the label L2009.
|
|
Double-click on the operand on line $2005 ("L2009") to open the operand
|
|
editor, then in the bottom left panel click "Create Label". Type "IS_OK",
|
|
then click "OK". Make sure the operand format is still set to Default,
|
|
then click "OK".</p>
|
|
<p>This puts the label IS_OK at line $2009, and we can see the BCC
|
|
instruction has it as well. We were able to leave the BCC instruction
|
|
set to Default format because the numeric reference to $2009 was
|
|
automatically resolved to the IS_OK label. You could do the same thing
|
|
by editing the label on line $2009 directly as we did earlier, but
|
|
in many cases -- particularly when the operand's target address is far
|
|
off screen -- it's more convenient to work through the operand editor.</p>
|
|
|
|
<h3>Unique vs. Non-Unique Labels</h3>
|
|
|
|
<p>Most assemblers have a notion of "local" labels, which go out of
|
|
scope when a non-local (global) label is encountered. The actual
|
|
definition of "local" is assembler-specific, but SourceGen allows you
|
|
to create labels that serve the same purpose.</p>
|
|
<p>By default, newly-created labels have global scope and must be
|
|
unique. You can change these attributes when you edit the label. Up near the
|
|
top of the file, at address $1002, double-click on the label ("L1002").
|
|
Change the label to "LOOP" and click the "non-unique local" button.
|
|
Click OK.</p>
|
|
<p>The label at line $1002 (and the operand on line $100B) should now
|
|
be "@LOOP". By default, '@' is used to indicate non-unique labels,
|
|
though you can change it to a different character in the application
|
|
settings.</p>
|
|
<p>At address $2019, double-click to edit the label ("L2019"). If
|
|
you type "MAIN" or "IS_OK" with Global selected you'll get an error,
|
|
but if you type "@LOOP" it will be accepted. Note the "non-unique local"
|
|
button is selected automatically if you start a label with '@' (or
|
|
whatever character you have configured). Click OK.</p>
|
|
<p>You now have two lines with the same label. The assembly source
|
|
generator may "promote" them to globals or rename them if your chosen
|
|
assembler requires it.</p>
|
|
|
|
<h3>Editing Data Operands</h3>
|
|
|
|
<p>There's some string and numeric data down at the bottom of the file. The
|
|
final string appears to be multiple strings stuck together. (You may need
|
|
to increase the width of the Operand column to see the whole thing.) Notice
|
|
that the opcode for the very last line is '+', which means it's a
|
|
continuation of the previous line. Long data items can span multiple
|
|
lines, split every 64 characters (including delimiters), but they are
|
|
still single items: selecting any part selects the whole.</p>
|
|
<p>Select the last line in the file, then Actions > Edit Operand. You'll
|
|
notice that this dialog is much different from the one you got when editing
|
|
the operand of an instruction. At the top it will say "65 bytes
|
|
selected". You can format this as a single 65-byte string, as 65 individual
|
|
items, or various things in between. For now, select "Single bytes", and
|
|
then on the right, select "ASCII (low or high) character". Click "OK".</p>
|
|
<p>Each character is now on its own line. The selection still spans the
|
|
same set of addresses.</p>
|
|
<p>Select address $203D on its own, then Actions > Edit Label. Set the
|
|
label to "STR1". Move up a bit and select address $2030, then scroll to
|
|
the bottom and shift-click address $2070. Select Actions > Edit Operand.
|
|
At the top it should now say, "65 bytes selected in 2 groups".
|
|
There are two groups because the presence of a label split the data into
|
|
two separate regions. From the "Character encoding" pop-up down in the
|
|
"String" section, make sure "Low or High ASCII" encoding is selected,
|
|
then select the "mixed character and non-character" string type and
|
|
click "OK".</p>
|
|
<p>We now have two ".STR" lines, one for "string zero ", and one with the
|
|
STR1 label and the rest of the string data. This is okay, but it's not
|
|
really what we want. The code at $200B appears to be loading a 16-bit
|
|
address from data at $2025, so we want to use that if we can.</p>
|
|
<p>Select Edit > Undo three times. You should be back to the state where
|
|
there's a single ".STR" line at the bottom of the file, split across two
|
|
lines with a '+'.</p>
|
|
<p>Select the line at $2026. This is currently formatted as a string,
|
|
but that appears to be incorrect, so let's format it as individual bytes
|
|
instead. There's an easy way to do that: use Actions > Toggle Single-Byte
|
|
Format (or hit Ctrl+B).</p>
|
|
<p>The data starting at $2025 appears to be 16-bit addresses that point
|
|
into the table of strings, so let's format them appropriately.</p>
|
|
<p>Double-click the operand column on line $2025 ("$30") to open
|
|
the operand data format editor. Because you only have one byte selected,
|
|
most of the options are disabled. This won't do what we want, so
|
|
click "Cancel".</p>
|
|
<p>Select the line at $2025, then shift-click the line at $202E. Right-click
|
|
and select Edit Operand. If you selected the correct set of bytes,
|
|
the top line in the dialog should now say, "10 bytes selected". Because
|
|
10 is a multiple of two, the 16-bit formats are enabled. It's not a multiple
|
|
of 3 or 4, so the 24-bit and 32-bit options are not enabled. Click the
|
|
"16-bit words, little-endian" radio button, then over to the right, click
|
|
the "Address" radio button. Click "OK".</p>
|
|
<p>We just told SourceGen that those 10 bytes are actually five 16-bit numeric
|
|
references. SourceGen determined that the addresses are contained in the
|
|
file, and created labels for each of them. Labels only work if they're
|
|
on their own line, so the long string was automatically split into five
|
|
separate ".STR" statements.</p>
|
|
|
|
<p>Use File > Save (or hit Ctrl+S) to save your work.</p>
|
|
|
|
|
|
<h3>Generating Assembly Code</h3>
|
|
|
|
<p>You can generate assembly source code from the disassembled data.
|
|
Select File > Assembler (or hit Ctrl+Shift+A) to open the source generation
|
|
and assembly dialog.</p>
|
|
<p>Pick your favorite assembler from the drop list at the top right,
|
|
then click "Generate". An assembly source file will be generated in the
|
|
directory where your project files lives, named after a combination of the
|
|
project name and the assembler name. A preview of the assembled code
|
|
appears in the top window. (It's a "preview" because it has line numbers
|
|
added and is cut off after a certain limit.)</p>
|
|
|
|
<p>If you have a cross-assembler installed and configured, you can run
|
|
it by clicking "Run Assembler". The output from the assembler will appear
|
|
in the lower window, along with an indication of whether the assembled
|
|
file matches the original. (Barring bugs in SourceGen or the assembler,
|
|
it should always match exactly.)</p>
|
|
|
|
<p>Click "Close" to close the window.</p>
|
|
|
|
|
|
<h3>End of Part One</h3>
|
|
|
|
<p>At this point you know enough to work with a SourceGen project. Continue
|
|
on to the next tutorial to learn more.</p>
|
|
|
|
<hr/>
|
|
|
|
|
|
<h2><a name="advanced-features">Tutorial #2: Advanced Features</a></h2>
|
|
|
|
<p>This tutorial will walk you through some of the fancier things SourceGen
|
|
can do. We assume you've already finished the Basic Features tutorial.</p>
|
|
|
|
|
|
<p>Start a new project. Select "Generic 6502". For the data file, navigate
|
|
to the Examples directory, then from the Tutorial directory
|
|
select "Tutorial2".</p>
|
|
<p>The first thing you'll notice is that we immediately ran into a BRK,
|
|
which is a pretty reliable sign that we're not in a code section. The
|
|
generic profile puts a code entry point hint on the first byte, but that's
|
|
wrong here. This particular file begins with <code>00 20</code>, which
|
|
could be a load address (some C64 binaries look like this). So let's start
|
|
with that assumption.</p>
|
|
<p>Click on the first line of code at address $1000, and select
|
|
Actions > Remove Hints. The $20 got absorbed into a string. The string
|
|
is making it hard to manipulate the next few bytes, so let's fix that by
|
|
selecting Edit > Toggle Data Scan (Ctrl+D). This turns off the feature
|
|
that looks for strings and .FILL regions, so now each uncategorized byte is
|
|
on its own line.</p>
|
|
<p>You could select the first two lines and use Actions > Edit Operand
|
|
to format them as a 16-bit little-endian hex value, but there's a shortcut:
|
|
select only the first line of code, then Actions > Format As Word (Ctrl+W). It
|
|
automatically grabbed the following byte and combined them. Since we believe
|
|
$2000 is the load address for everything that follows, click on the line
|
|
with address $1002, select Actions > Set Address, and enter "2000". With
|
|
that line still selected, use Actions > Hint As Code Entry Point
|
|
(Ctrl+H then Ctrl+C) to identify it as code.</p>
|
|
<p>That looks better, but it's branching off the bottom of the screen
|
|
(unless you have a really tall screen or small fonts) because of all the
|
|
intervening data. Use Edit > Toggle Data Scan to turn the string
|
|
finder back on.</p>
|
|
|
|
<p>There are four strings starting at address $2004, each of which is
|
|
followed by $00. These look like null-terminated strings, so let's make
|
|
it official. But first, let's do it wrong. Click on the line with
|
|
address $2004 to select it. Hold the shift key down, then double-click
|
|
on the operand field of the line with address $2031 (i.e. double-click on
|
|
the words "last string").</p>
|
|
<p>The Edit Data Operand dialog opens, but the null-terminated strings
|
|
option is not available. This is because we didn't include the null byte
|
|
on the last string. To be recognized as one of the "special" string types,
|
|
every selected string must match the expected pattern.</p>
|
|
<p>Cancel out of the dialog. Hold the shift key down, and double-click
|
|
on the operand on line $203c (<code>$00</code>).
|
|
You should see "Null-terminated strings (4)" as an available
|
|
option now (make sure the Character Encoding pop-up is set to
|
|
"Low or High ASCII"). Click on that, then click "OK". The strings are now
|
|
shown as .ZSTR operands.</p>
|
|
|
|
<p>It's wise to save your work periodically. Use File > Save to create
|
|
a project file for Tutorial2.</p>
|
|
|
|
<h4>Pointers and Parts</h4>
|
|
|
|
<p>Let's move on to the code at $203d. It starts by storing a couple of
|
|
values into direct page address $02/03. This appears to be setting up a
|
|
pointer to $2063, which is a data area inside the file. So let's make it
|
|
official.</p>
|
|
<p>Select the line at address $2063, and use Actions > Edit Label to
|
|
give it the label "XDATA?". The question mark on the end is there to
|
|
remind us that we're not entirely sure what this is. Now edit the
|
|
operand on line $203d, and set it to the symbol "XDATA", with the part
|
|
"low". The question mark isn't really part of the label, so you don't
|
|
need to type it here. Edit the operand on line $2041,
|
|
and set it to "XDATA" with the part "high". (The symbol text box
|
|
gets focus immediately, so you can start typing the symbol name as soon
|
|
as the dialog opens; you don't need to click around first.) If all
|
|
went well, the operands should now read <code>LDA #<XDATA?</code>
|
|
and <code>LDA #>XDATA?</code>.</p>
|
|
<p>Let's give the pointer a name. Select line $203d, and use
|
|
Actions > Create Local Variable Table to create an empty table.
|
|
Click "New Symbol" on the right side. Leave the Address button selected.
|
|
Set the Label field to "PTR1", the Value field to $02, and the width
|
|
to 2 (it's a 2-byte pointer). Click "OK" to create the entry, and then
|
|
"OK" to update the table.</p>
|
|
<p>There's now a ".var" statement (similar to a .equ) above line $203d,
|
|
and the stores to $02/$03 have changed to "PTR1" and "PTR1+1".</p>
|
|
<p>Double-click on the JSR on line $2045 to jump to L209A. This just
|
|
loads a value from $3000 into the accumulator and returns, so not much
|
|
to see here. Hit the back-arrow in the toolbar to jump back to the JSR.</p>
|
|
<p>The next bit of code masks the accumulator so it holds a value between
|
|
0 and 3, then doubles it and uses it as an index into PTR1. We know PTR1
|
|
points to XDATA, which looks like it has some 16-bit addresses. The
|
|
values loaded are stored in two more zero-page locations, $04-05.</p>
|
|
<p>Let's make these a pointer as well. Double-click the operand on
|
|
line $204e ("$04"), and click "Create Local Variable". Set the Label
|
|
to "PTR2" and the width to 2. Click "OK" to create the symbol, then
|
|
"OK" to close the operand editor, which should still be set to Default --
|
|
we didn't actually edit the operand, we just used the operand edit
|
|
dialog as a convenient way to create a local variable table entry. All
|
|
accesses to $04/$05 now use PTR2, and there's a new entry in the local
|
|
variable table we created earlier.</p>
|
|
|
|
<p>The next bit of code copies bytes from PTR2 to $0400, stopping when it
|
|
hits a zero byte. Looks like this is copying null-terminated strings.
|
|
This confirms our idea that XDATA holds 16-bit addresses, so let's
|
|
format it. Select lines $2063 to $2066, and Actions > Edit Operand.
|
|
It should say "8 bytes selected" at the top. Select "16-bit words,
|
|
little-endian", and then from the Display As box, select "Address".
|
|
Click "OK". XDATA should now be four <code>.dd2</code> 16-bit addresses.
|
|
If you scroll up, you'll see that the .ZSTR strings near the top now have
|
|
labels that match the operands in XDATA.</p>
|
|
<p>Now that we know what XDATA holds, let's rename it. Change the label
|
|
to STRADDR. The symbol parts in the operands at $203d and $2041 update
|
|
automatically.</p>
|
|
|
|
<p>Let's pause briefly to look at the cycle-count feature. Use
|
|
Edit > Settings to open the app settings panel, then select the
|
|
Asm Config tab. Click the "Show cycle counts" checkbox, then click "OK".</p>
|
|
<p>Every line with an instruction now has a cycle count on it. The cycle
|
|
counts are adjusted for everything SourceGen can figure out. For example,
|
|
the BEQ on line $205a shows "2+" cycles, meaning that it takes at least two
|
|
cycles but might take more. That's because conditional branches take an
|
|
extra cycle if the branch is taken. The BNE on line $2061" shows 3 cycles,
|
|
because we know that the branch is always taken. (If you want to see why,
|
|
look at the value of the 'Z' flag in the "flags" column. Lower-case 'z'
|
|
means the zero-flag is clear. You can see it got set on the
|
|
<code>ORA #$80</code> line.)</p>
|
|
<p>The cycle-count comments are included in assembled output as well. If
|
|
you add an end-of-line comment, it appears after the cycle count.</p>
|
|
<p>Hit Ctrl+S to save your project. Make that a habit.</p>
|
|
|
|
<h4>Inline Data</h4>
|
|
|
|
<p>Consider the code at address $206B. It's a JSR followed by some
|
|
ASCII text, then a $00 byte, and then what might be code. Double-click
|
|
on the JSR opcode to jump to $20AB to see the function. It pulls the
|
|
call address off the stack, and uses it as a pointer. When it encounters
|
|
a zero byte, it breaks out of the loop, pushes the adjusted pointer
|
|
value back onto the stack, and returns.</p>
|
|
<p>This is an example of "inline data", where a function uses the return
|
|
address to get a pointer to data. The return address is adjusted to
|
|
point past the inline data before returning (technically, it points at
|
|
the very last byte of the inline data, because RTS jumps to address + 1).</p>
|
|
<p>To format the data, we first need to tell SourceGen that there's data
|
|
in line with the code. Select the line at address $206E, then
|
|
shift-click the line at address $2077. Use Actions > Hint as Inline Data.</p>
|
|
<p>The data turns to single-byte values, and we now see the code
|
|
continuing at address $2078. We can format the data as string by
|
|
using Actions > Edit Operand, setting the Character Encoding to "Low or
|
|
High ASCII", and choosing "null-terminated strings".</p>
|
|
|
|
<p>That's pretty straightforward, but this could quickly become tedious if
|
|
there were a lot of these. SourceGen allows you to define scripts to
|
|
automate common formatting tasks. This is covered in a later tutorial.</p>
|
|
|
|
<h4>Odds & Ends</h4>
|
|
|
|
<p>The rest of the code isn't really intended to do anything useful. It
|
|
just exists to illustrate some odd situations.</p>
|
|
<p>Look at the code starting at $2078. It ends with a BRK at $2081, which
|
|
as noted earlier is a bad sign. If you look two lines above the BRK,
|
|
you'll see that it's loading the accumulator with zero, then doing a BNE,
|
|
which should never be taken (note the cycle count for the BNE is 2). The
|
|
trick is in the two lines before that, which use self-modifying code to
|
|
change the LDA immediate operand from $00 to $ff. The BNE is actually
|
|
a branch-always.</p>
|
|
<p>We can fix this by correcting the status flags. Select line $207F,
|
|
and then Actions > Override Status Flags. This lets us specify what
|
|
the flags should be before the instruction is executed. For each flag,
|
|
we can override the default behavior and specify that the flag is
|
|
clear (0), set (1), or indeterminate (could be 0 or 1). In this case,
|
|
we know that the self-modified code will be loading a non-zero value, so
|
|
in the "Z" column click on the button in the "Zero" row. Click "OK". The
|
|
BNE is now an always-taken branch, and the code list rearranges itself
|
|
appropriately (and the cycle count is now 3).</p>
|
|
|
|
<p>Continuing on, the code at $2086 touches a few consecutive locations. Edit
|
|
the label on line $2081, setting it to "STUFF". Notice how the references
|
|
to $2081 through $2084 have changed from auto-generated labels to
|
|
references to STUFF. For some projects this may be undesirable. Use
|
|
Edit > Project Properties, then in the Analysis Parameters box
|
|
un-check "Seek nearby targets", and click "OK". You'll notice that the
|
|
references to $2081 and later have switched back to auto labels. If
|
|
you scroll up, you'll see that the references to PTR1+1 and PTR2+1 were
|
|
not affected, because local variables use explicit widths rather
|
|
than the "nearby" logic.</p>
|
|
<p>The nearby-target behavior is generally desirable, because it lets you
|
|
avoid explicitly labeling every part of a multi-byte data item. For now,
|
|
use Edit > Undo to switch it back on.</p>
|
|
|
|
<p>The code at $2092 looks a bit strange. <code>LDX</code>, then a
|
|
<code>BIT</code> with a weird symbol, then another <code>LDX</code>. If
|
|
you look at the "bytes" column, you'll notice that the three-byte
|
|
<code>BIT</code> instruction has only one byte on its line. The
|
|
trick here is that the <code>LDX #$01</code> is embedded inside the
|
|
<code>BIT</code> instruction. When the code runs through here, X is set
|
|
to $00, then the <code>BIT</code> instruction sets some flags, then the
|
|
<code>STA</code> runs. Several lines down there's a <code>BNE</code>
|
|
to $2095, which is in the middle of the <code>BIT</code> instruction.
|
|
It loads X with $01, then also continues to the <code>STA</code>.</p>
|
|
<p>Embedded instructions are unusual but not unheard-of. (This trick is
|
|
used extensively in Microsoft BASICs, such as Applesoft.) When you see the
|
|
extra symbol in the opcode field, you need to look closely at what's going
|
|
on.</p>
|
|
|
|
<hr/>
|
|
|
|
|
|
<h2><a name="address-tables">Tutorial #3: Address Table Formatting</a></h2>
|
|
|
|
<p><i>This tutorial covers one specific feature.</i></p>
|
|
|
|
<p>Start a new project. Select the Apple //e platform, click Select File
|
|
and navigate to the Examples directory. In A2-Amper-fdraw, select
|
|
<code>AMPERFDRAW#061d60</code>. Click "OK" to create the project.</p>
|
|
<p>Not a lot to see here -- just half a dozen lines of loads and stores.
|
|
This particular program interfaces with Applesoft BASIC, so we can make it
|
|
a bit more meaningful by loading an additional platform
|
|
symbol file. Select Edit > Project Properties, then the Symbol Files
|
|
tab. Click Add Symbol Files from Runtime. The file browser starts in
|
|
the RuntimeData directory. Open the "Apple" folder, then select
|
|
<code>Applesoft.sym65</code>, and click "Open". Click "OK" to close
|
|
the project properties window.</p>
|
|
<p>The <code>STA</code> instructions now reference <code>BAS_AMPERV</code>,
|
|
which is noted as a code vector. We can see the code setting up a jump
|
|
(opcode $4c) to $1d70. As it happens, the start address of the code
|
|
is $1d60 -- the last four digits of the filename -- so let's make that
|
|
change. Double-click the initial .ORG statement, and change it from
|
|
$2000 to $1d60. We can now see that $1d70 starts right after this
|
|
initial chunk of code.</p>
|
|
|
|
<p>Select the line with address $1d70, then Actions > Hint As Code
|
|
Entry Point.
|
|
More code appears, but not much -- if you scroll down you'll see that most
|
|
of the file is still data. The code at $1d70 searches through a table at
|
|
$1d88 for a match with the contents of the accumulator. If it finds a match,
|
|
it loads bytes from tables at $1da6 and $1d97, pushes them on the stack,
|
|
and the JMPs away. This code is pushing a return address onto the stack.
|
|
When the code at <code>BAS_CHRGET</code> returns, it'll return to that
|
|
address. Because of a quirk of the 6502 architecture, the address pushed
|
|
must be the desired address minus one.</p>
|
|
<p>The first byte in the first address table at $1d97 (which has the auto-label
|
|
L1D97) is $b4. The first byte in the second table is $1d. So the first
|
|
address we want is $1db4 + 1 = $1db5.</p>
|
|
<p>Select the line at $1db5, and use Actions > Hint As Code Entry Point.
|
|
More code appears, but again it's only a few lines. Let's dress this one
|
|
up a bit. Set a label on the code at $1db5 called "FUNC". At $1d97, edit
|
|
the data item (double-click on "$b4"), click "Single bytes", then type "FUNC"
|
|
(note the text field gets focus immediately, and the radio button
|
|
automatically switches to "symbolic reference" when you start typing).
|
|
Click "OK". The operand at $1d97 should now say <code><FUNC-1</code>.
|
|
Repeat the process at $1da6, this time clicking the "High" part radio button
|
|
below the symbol entry text box,
|
|
to make the operand there say <code>>FUNC</code>. (If it says
|
|
<code><FUNC-152</code>, you forgot to select the High part.)</p>
|
|
|
|
<p>We've now changed the first entry in the table to symbolic references.
|
|
You could repeat these steps for the remaining items, but there's a faster
|
|
way. Click on the line at address $1d97, then shift-click the line at
|
|
address $1da9 (which should be <code>.FILL 12,$1e</code>). Select
|
|
Actions > Format Address Table.</p>
|
|
<p>Contrary to first impressions, this imposing dialog does not allow you
|
|
to launch objects into orbit. There are a variety of common ways to
|
|
structure an address table, all of which are handled here. You can
|
|
configure the various parameters and see the effects as you make
|
|
each change.</p>
|
|
<p>The message at the top should indicate that there are 30 bytes
|
|
selected. In Address Characteristics, click the "Parts are split across
|
|
sub-tables" checkbox and the "adjusted for RTS/RTL"
|
|
checkbox. As soon as you do, the first line of the Generated Addresses
|
|
list should show the symbol "FUNC". The rest of the addresses will look like
|
|
<code>(+) T1DD0</code>. The "(+)" means that a label was not found at
|
|
that location, so a label will be generated automatically.</p>
|
|
<p>Down near the bottom, check the "add code entry hint if needed" checkbox.
|
|
Because we saw the table contents being pushed onto the stack for RTS,
|
|
we know that they're all code entry points.</p>
|
|
<p>Click "OK". The table of address bytes at $1d97 should now all be
|
|
references to symbols -- 15 low parts followed by 15 high parts. If you
|
|
scroll down, you should see nothing but instructions until you get to the
|
|
last dozen bytes at the end of the file. (If this isn't the case, use
|
|
Edit > Undo, then work through the steps again.)</p>
|
|
<p>The formatter did the same steps you went through earlier -- set a
|
|
label, apply the label to the low and high bytes in the table, add a
|
|
code entry point hint -- but did several of them at once.</p>
|
|
|
|
<p>We don't want to save this project, so select File > Close. When
|
|
SourceGen asks for confirmation, click Discard & Continue.</p>
|
|
|
|
<hr/>
|
|
|
|
|
|
<h2><a name="extension-scripts">Tutorial #4: Extension Scripts</a></h2>
|
|
|
|
<p><i>This tutorial covers one specific feature.</i></p>
|
|
|
|
<p>Some repetitive formatting tasks can be handled with automatic scripts.
|
|
This is especially useful for inline data, which can confuse the code
|
|
analyzer.</p>
|
|
<p>An earlier tutorial demonstrated how to manually mark bytes as
|
|
inline data. We're going to do it a faster way. For this tutorial,
|
|
start a new project with "Generic 6502", and in the SourceGen
|
|
Examples/Tutorial directory select "Tutorial4".</p>
|
|
<p>We'll need to load scripts from the project directory, so we have to
|
|
save the project. File > Save, use the default name ("Tutorial4.dis65").</p>
|
|
|
|
<p>Take a look at the disassembly listing. The file starts with a JSR
|
|
followed by a string that begins with a small number. This appears to be
|
|
a string with a leading length byte. We want to load a script that
|
|
can handle that, so use Edit > Project Properties, select the
|
|
Extension Scripts tab, and click "Add Scripts from Project". The file
|
|
browser opens in the project directory. Select the file
|
|
"InlineL1String.cs", click Open, then OK.</p>
|
|
<p>Nothing happened. If you look at the script with an editor (and you
|
|
know some C#), you'll see that it's looking for a JSR to a function called
|
|
"PrintInlineL1String". So let's give it one.</p>
|
|
<p>Double-click the JSR operand ("L1026"), click "Create Label", and
|
|
enter "PrintInlineL1String". Remember that labels are case-sensitive;
|
|
you must enter it exactly as shown. Hit "OK" to accept the label, and "OK"
|
|
to close the operand editor. If all went well, address $1003 should now be
|
|
an L1 string "How long?", and adress $100D should be another JSR.</p>
|
|
|
|
<p>The next JSR appears to be followed by a null-terminated string, so
|
|
we'll need something that handles that. Go back into Project Properties
|
|
and add the script "InlineNullTermString.cs".</p>
|
|
<p>This script is slightly different, in that it handles any JSR to a label
|
|
that starts with "PrintInlineNullString". So let's give it a couple of
|
|
those.</p>
|
|
<p>Double-click the operand on line $100D ("L1027"), click Create Label,
|
|
and set the label to "PrintInlineNullStringOne". Hit "OK" twice. That
|
|
formatted the first one and got us to the next JSR. Repeat the process
|
|
on line $1019 ("L1028"), setting the label to "PrintInlineNullStringTwo".</p>
|
|
|
|
<p>The entire project is now nicely formatted. In a real project the
|
|
"Print Inline" locations would be actual print functions, not just RTS
|
|
instructions. There would likely be multiple JSRs to the print function,
|
|
so labeling a single function entry point could format dozens of inline
|
|
strings and clean up the disassembly automatically. The reason for
|
|
allowing wildcard names is that some functions may have multiple
|
|
entry points or chain through different locations.</p>
|
|
|
|
<p>Extension scripts can make your life much easier, but they do require
|
|
some programming experience. See the
|
|
<a href="advanced.html#extension-scripts">manual</a> for more details.</p>
|
|
|
|
<hr/>
|
|
|
|
|
|
<h2><a name="visualizations">Tutorial #5: Visualizations</a></h2>
|
|
|
|
<p><i>This tutorial covers one specific feature.</i></p>
|
|
|
|
<p>Many programs contain a significant amount of graphical data. This is
|
|
especially true for games, where the space used for bitmaps is often
|
|
larger than the space required for the code. When disassembling a program
|
|
it can be very helpful to be able to see the contents of the data
|
|
regions in graphical form.</p>
|
|
|
|
<p>Start a new project with "Generic 6502", and in the SourceGen Tutorial
|
|
directory select "Tutorial5". We'll need to load an extension script from
|
|
the project directory, so immediately save the project, using the
|
|
default name ("Tutorial5.dis65").</p>
|
|
<p>Normally a project will give you some sort of hint as to the data
|
|
format, e.g. the graphics might be a platform-specific sprite. For
|
|
non-standard formats you can glean dimensions from the drawing code. For
|
|
the purposes of this tutorial we're just using a simple monochrome bitmap
|
|
format, with 8 pixels per byte, and we'll know that our images are for
|
|
a Tic-Tac-Toe game. The 'X' and the 'O' are 8x8, the game board is 40x40.
|
|
The bitmaps are sprites with transparency, so pixels are either solid
|
|
or transparent.</p>
|
|
<p>The first thing we need to do is load an extension script that can
|
|
decode this format. The RuntimeData directory has a few, but for this
|
|
tutorial we're using a custom one. Select Edit > Project Properties,
|
|
select the Extension Scripts tab, and click "Add Scripts from Project".
|
|
Double-click on "VisTutorial5.cs", then click "OK".</p>
|
|
|
|
<p>The address of the three bitmaps are helpfully identified by the
|
|
load instructions at the top of the file. Select the list at
|
|
address $100A, then Actions > Create/Edit Visualization Set. In
|
|
the window that opens, click "New Bitmap".</p>
|
|
<p>We're going to ignore most of what's going on and just focus on the
|
|
list of parameters at the bottom. The file offset indicates where in
|
|
the file the bitmap starts; note this is an offset, not an address
|
|
(that way, if you change the address, your visualizations don't break).
|
|
This is followed by the bitmap's width in bytes, and the bitmap's height.
|
|
Because we have 8 pixels per byte, we're currently showing a 1x1 image.
|
|
We'll come back to row stride.</p>
|
|
<p>We happen to know (by playing the game and/or reading the fictitious
|
|
drawing code) that the image is 8x8, so change the value in the height
|
|
field to 8. As soon as you do, the preview window shows a big blue 'X'.
|
|
(The 'X' is 7x7; the last row/column of pixels are transparent so adjacent
|
|
images don't blend into each other.)</p>
|
|
<p>Let's try doing it wrong. Add a 0 to make the height 80. You can see
|
|
some additional bitmap data. Add another 0 to make it 800. Now you get
|
|
a big red X, and the "Height" parameter is shown in red. That's because
|
|
the maximum value for the height is 512, as shown by "[1,512]" on the
|
|
right.</p>
|
|
<p>Change it back to 8, and hit "OK". Hit "OK" in the Edit Visualization
|
|
Set window as well. You should now see the blue 'X' in the code listing
|
|
above line $100A.</p>
|
|
|
|
<p>Repeat the process at line $1012: select the line, create a visualization
|
|
set, create a new bitmap, set the height to 8, click "OK" twice.</p>
|
|
|
|
<p>Repeat the process at line $101A, but this time the image is 40x40
|
|
rather than 8x8. Set the width to 5, and the height to 40. This makes
|
|
a mess.</p>
|
|
<p>In this case, the bitmap data is 5 bytes wide, but the data is stored
|
|
as 8 bytes per row. This is known as the "stride" or "pitch" of the row.
|
|
To tell the visualizer to skip the last 3 bytes on each row, set the
|
|
"Row stride (bytes)" field to 8. Now we have a proper Tic-Tac-Toe grid.
|
|
Note that it fills the preview window just as the 'X' and 'O' did, even
|
|
though it's 5x as large. The preview window scales everything up. Hit
|
|
"OK" twice to create the visualization.</p>
|
|
<p>Let's format the bitmap data. Select line $101A, then shift-click the
|
|
last line in the file ($1159). Actions > Edit Operand. Select
|
|
"densely-packed bytes", and click "OK". This is perhaps a little too
|
|
dense. Open the operand editor again, but this time select the
|
|
densely-packed bytes sub-option "...with a limit", and set the limit
|
|
to 8 bytes per line. Instead of one very dense statement spread across
|
|
a few lines, you get one line of code per row of bitmap. If you prefer
|
|
to see individual bytes, you can use Edit > Settings, select the
|
|
Display Format tab, and check "use comma-separated format for bulk data".
|
|
This can make it a bit easier to read.</p>
|
|
|
|
<h4>Animations</h4>
|
|
|
|
<p>Some graphics represent individual frames in an animated sequence.
|
|
You can convert those as well. Double-click on the blue 'X' to open
|
|
the visualization set editor, then click "New Bitmap Animation". This
|
|
opens the Bitmap Animation Editor.</p>
|
|
<p>Let's try it with our Tic-Tac-Toe board pieces. From the list on the
|
|
left, select the blue 'X' and click "Add", then click the 'O' and click
|
|
"Add". Below the list, set the frame delay to 500. Near the bottom,
|
|
click "Start / Stop. This causes the animation to play in a loop. You
|
|
can use the controls to add and remove items, change their order, and change
|
|
the animation speed. You can add the grid to the animation set, but the
|
|
preview scales the bitmaps up to full size, so it may not look the way
|
|
you expect.</p>
|
|
<p>Hit "OK" to save the animation, then "OK" to update the visualization set.
|
|
The code list now shows two entries in the line: the first is the 'X'
|
|
bitmap, the second is the animation, which is shown as the initial frame
|
|
with a blue triangle superimposed. (If you go back into the editor and
|
|
reverse the order of the frames, the list will show the 'O' instead.)
|
|
You can have as many bitmaps and animations on a line as you want.</p>
|
|
<p>If you have a lot of bitmaps it can be helpful to give them meaningful
|
|
names, so that they're easy to identify and sort together in the list.
|
|
The "tag" field at the top of the editor windows lets you give things
|
|
names. Tags must be unique.</p>
|
|
|
|
<h4>Other Notes</h4>
|
|
|
|
<p>The visualization editor is intended to be very dynamic, showing the
|
|
results of parameter changes immediately. This can be helpful if you're
|
|
not exactly sure what the size or format of a bitmap is. Just keep
|
|
tweaking values until it looks right.</p>
|
|
|
|
<p>Visualization generators are defined by extension scripts. If you're
|
|
disassembling a program with a totally custom way of storing graphics,
|
|
you can write a totally custom visualizer and distribute it with the
|
|
project. Because the file offset is a parameter, you're not limited to
|
|
placing visualizations at the start of the graphic data -- you can put
|
|
them on any code or data line.</p>
|
|
|
|
<p>Visualizations have no effect on assembly source code generation,
|
|
but they do appear in code exported to HTML. Bitmaps are converted to GIF
|
|
images, and animations become animated GIFs.</p>
|
|
|
|
<hr/>
|
|
|
|
|
|
<h2>End of Tutorials</h2>
|
|
|
|
<p>That's it for the tutorials. Significantly more detail on
|
|
all aspects of SourceGen can be found in the manual.</p>
|
|
<p>While you can do some fancy things, nothing you do will alter the
|
|
data file. The assembled output will always match the original. So
|
|
don't be afraid to play around.</p>
|
|
<p>If you want to work on something large over a long period, save your
|
|
progress by putting the .dis65 project into a source code control system
|
|
like git. Project files are stored in a text format that, while not meant
|
|
to be human-readable, should yield reasonable diffs.</p>
|
|
|
|
</div>
|
|
|
|
<div id="footer">
|
|
<p><a href="index.html">Back to index</a></p>
|
|
</div>
|
|
</body>
|
|
<!-- Copyright 2018 faddenSoft -->
|
|
</html>
|