1
0
mirror of https://github.com/fadden/6502bench.git synced 2024-12-12 05:31:04 +00:00
6502bench/SourceGen/RuntimeData
Andy McFadden 309cc88a54 Improve split-address table formatter
Don't enable OK unless at least one address is valid.
Don't apply code hints unless asked.
Rename a couple of things for clarity.
Add documentation to manual.

(issue #10)
2018-10-06 21:15:59 -07:00
..
Apple Fix some comments 2018-10-01 15:24:27 -07:00
Atari Initial file commit 2018-09-28 10:05:11 -07:00
Help Improve split-address table formatter 2018-10-06 21:15:59 -07:00
Nintendo Initial file commit 2018-09-28 10:05:11 -07:00
TestData Initial file commit 2018-09-28 10:05:11 -07:00
AboutImage.png Initial file commit 2018-09-28 10:05:11 -07:00
ExtensionScripts.md Initial file commit 2018-09-28 10:05:11 -07:00
LegalStuff.txt Initial file commit 2018-09-28 10:05:11 -07:00
Logo.png Initial file commit 2018-09-28 10:05:11 -07:00
README.md Initial file commit 2018-09-28 10:05:11 -07:00
RuntimeData.csproj Initial file commit 2018-09-28 10:05:11 -07:00
SystemDefs.json Add first-word-is-load-addr parameter to system definitions 2018-10-05 15:39:44 -07:00

Runtime Data

Symbol files and analyzer scripts are split into directories by platform manufacturer.

The Visual Studio project (RuntimeData.csproj) exists so you can edit scripts with IntelliSense and error highlighting. Everything here is distributed as source, not in compiled form; all compilation occurs at run time.

SystemDefs.json

This file defines the systems available in the "new project" screen. The following fields are mandatory:

  • Name - Short name that identifies the system.
  • GroupName - Short string used to group common items together in the UI.
  • CPU - Type of CPU used. The string must be part of the known set (see CpuDef.cs)
  • Speed - Clock rate, in MHz, of the CPU on the system. When multiple speeds are possible, use the most common, favoring NTSC over PAL.
  • SymbolFiles - List of platform symbol file identifiers (see below).
  • ExtensionScripts - List of extension script file identifiers (see below).
  • Parameters - List of optional parameters (see below).

The currently-supported parameters are:

  • load-address= - Specify the initial load address. The default is 0x1000.
  • entry-flags= - Specify the processor status flag values to use at entry points. This is intended for use on the 65802/65816, and may be one of "emulation", "native-short", and "native-long". The default is "emulation".
  • undocumented-opcodes={true|false} - Enable or disable undocumented opcodes. They are disabled by default.

All of these things can be changed after the project has begun, but it's nice to have them configured in advance.

SymbolFiles and ExtensionScripts use file identifiers, which look like "RT:Apple/ProDOS8.sym65". The "RT:" means that the file lives in the RuntimeData directory, and the rest is a partial pathname. Files that live in the same directory as the project file are prefixed with "PROJ:". All symbol files and extension scripts must live in the RuntimeData directory or project file directory, or they will not be loaded.

All "RT:" identifier paths are relative to the RuntimeData directory. The Group Name is not automatically added.

Platform Symbol Files (.sym65)

These contain lists of symbols, each of which has a label and a value. If two symbols have the same value, the older one is discarded.

Blank lines, and lines that begin with a semicolon (';'), are ignored.

Lines that begin with an asterisk are command lines. Two commands are currently defined:

  • *SYNOPSIS - a short summary of the file contents.
  • *TAG - a tag string to apply to all following symbols.

Tags can be used by extension scripts to identify a subset of symbols. The symbols are still part of the global set; the tag just provides a way to extract a subset. Tags should be comprised of non-whitespace ASCII characters. Tags are global, so use a long descriptive string. If *TAG is not followed by a string, the tag is cleared.

All other lines are expected to have the form:

symbol {=|@} value [;comment]

Symbols must be at least two characters long, begin with a letter or underscore, and consist entirely of alphanumeric ASCII characters (A-Z, a-z, 0-9) and the underscore. Different assemblers have different limitations on symbols, but all reasonable assemblers will accept these.

Use '@' for address values, and '=' for constants. The only real difference is that address values will be applied automatically to operands that reference addresses outside the scope of the file.

The value is a number in decimal, hexadecimal (with a leading '$'), or binary (with a leading '%'). The numeric base will be saved and used when formatting the symbol in the generated output, so use whichever form is most appropriate. Values are unsigned 24-bit numbers.

The comment is optional. If present, it will be saved and used as the end-of-line comment on the equate directive if the symbol is used.

Extension Scripts

See "ExtensionScripts.md".