1
0
mirror of https://github.com/TomHarte/CLK.git synced 2024-11-23 03:32:32 +00:00
CLK/Components/6522/6522.hpp

145 lines
4.2 KiB
C++
Raw Normal View History

2016-07-10 12:05:05 +00:00
//
// 6522.hpp
// Clock Signal
//
// Created by Thomas Harte on 06/06/2016.
// Copyright 2016 Thomas Harte. All rights reserved.
//
#ifndef _522_hpp
#define _522_hpp
#include <cstdint>
#include "Implementation/6522Storage.hpp"
2017-07-27 12:05:14 +00:00
#include "../../ClockReceiver/ClockReceiver.hpp"
2023-05-10 21:02:18 +00:00
namespace MOS::MOS6522 {
enum Port {
A = 0,
B = 1
};
enum Line {
One = 0,
Two = 1
};
/*!
Provides the mechanism for just-int-time communication from a 6522; the normal use case is to compose a
6522 and a subclass of PortHandler in order to reproduce a 6522 and its original bus wiring.
*/
class PortHandler {
public:
/// Requests the current input value of @c port from the port handler.
2021-07-18 15:29:26 +00:00
uint8_t get_port_input([[maybe_unused]] Port port) {
return 0xff;
}
/// Sets the current output value of @c port and provides @c direction_mask, indicating which pins are marked as output.
2021-07-18 15:29:26 +00:00
void set_port_output([[maybe_unused]] Port port, [[maybe_unused]] uint8_t value, [[maybe_unused]] uint8_t direction_mask) {}
/// Sets the current logical output level for line @c line on port @c port.
2021-07-18 15:29:26 +00:00
void set_control_line_output([[maybe_unused]] Port port, [[maybe_unused]] Line line, [[maybe_unused]] bool value) {}
/// Sets the current logical value of the interrupt line.
2021-07-18 15:29:26 +00:00
void set_interrupt_status([[maybe_unused]] bool status) {}
/// Provides a measure of time elapsed between other calls.
2021-07-18 15:29:26 +00:00
void run_for([[maybe_unused]] HalfCycles duration) {}
/// Receives passed-on flush() calls from the 6522.
2021-07-18 15:29:26 +00:00
void flush() {}
};
/*!
Provided as an optional alternative base to @c PortHandler for port handlers; via the delegate pattern adds
a virtual level of indirection for receiving changes to the interrupt line.
*/
class IRQDelegatePortHandler: public PortHandler {
public:
class Delegate {
public:
/// Indicates that the interrupt status has changed for the IRQDelegatePortHandler provided.
virtual void mos6522_did_change_interrupt_status(void *irq_delegate) = 0;
};
/// Sets the delegate that will receive notification of changes in the interrupt line.
void set_interrupt_delegate(Delegate *delegate);
/// Overrides PortHandler::set_interrupt_status, notifying the delegate if one is set.
void set_interrupt_status(bool new_status);
private:
Delegate *delegate_ = nullptr;
};
/*!
Implements a template for emulation of the MOS 6522 Versatile Interface Adaptor ('VIA').
The VIA provides:
* two timers, each of which may trigger interrupts and one of which may repeat;
* two digial input/output ports; and
* a serial-to-parallel shifter.
Consumers should derive their own curiously-recurring-template-pattern subclass,
implementing bus communications as required.
*/
template <class BusHandlerT> class MOS6522: public MOS6522Storage {
public:
MOS6522(BusHandlerT &bus_handler) noexcept : bus_handler_(bus_handler) {}
MOS6522(const MOS6522 &) = delete;
/*! Sets a register value. */
void write(int address, uint8_t value);
/*! Gets a register value. */
uint8_t read(int address);
/*! @returns the bus handler. */
BusHandlerT &bus_handler();
/// Sets the input value of line @c line on port @c port.
void set_control_line_input(Port port, Line line, bool value);
/// Runs for a specified number of half cycles.
void run_for(const HalfCycles half_cycles);
/// Runs for a specified number of cycles.
void run_for(const Cycles cycles);
/// @returns @c true if the IRQ line is currently active; @c false otherwise.
2020-05-10 01:22:51 +00:00
bool get_interrupt_line() const;
/// Updates the port handler to the current time and then requests that it flush.
void flush();
private:
void do_phase1();
void do_phase2();
2019-05-08 18:54:40 +00:00
void shift_in();
void shift_out();
BusHandlerT &bus_handler_;
HalfCycles time_since_bus_handler_call_;
void access(int address);
uint8_t get_port_input(Port port, uint8_t output_mask, uint8_t output, uint8_t timer_mask);
inline void reevaluate_interrupts();
/// Sets the current intended output value for the port and line;
/// if this affects the visible output, it will be passed to the handler.
void set_control_line_output(Port port, Line line, LineState value);
void evaluate_cb2_output();
void evaluate_port_b_output();
};
}
2019-03-02 23:07:05 +00:00
#include "Implementation/6522Implementation.hpp"
#endif /* _522_hpp */