mirror of
https://github.com/TomHarte/CLK.git
synced 2024-12-11 15:49:38 +00:00
540 lines
14 KiB
C++
540 lines
14 KiB
C++
//
|
|
// Z80.hpp
|
|
// Clock Signal
|
|
//
|
|
// Created by Thomas Harte on 14/05/2017.
|
|
// Copyright 2017 Thomas Harte. All rights reserved.
|
|
//
|
|
|
|
#pragma once
|
|
|
|
#include <algorithm>
|
|
#include <cassert>
|
|
#include <vector>
|
|
#include <cstdint>
|
|
|
|
#include "../../Numeric/RegisterSizes.hpp"
|
|
#include "../../ClockReceiver/ClockReceiver.hpp"
|
|
#include "../../ClockReceiver/ForceInline.hpp"
|
|
|
|
namespace CPU::Z80 {
|
|
|
|
/*
|
|
The list of registers that can be accessed via @c value_of(Register) and @c set_value_of(Register).
|
|
*/
|
|
enum class Register {
|
|
ProgramCounter,
|
|
StackPointer,
|
|
|
|
A, Flags, AF,
|
|
B, C, BC,
|
|
D, E, DE,
|
|
H, L, HL,
|
|
|
|
ADash, FlagsDash, AFDash,
|
|
BDash, CDash, BCDash,
|
|
DDash, EDash, DEDash,
|
|
HDash, LDash, HLDash,
|
|
|
|
IXh, IXl, IX,
|
|
IYh, IYl, IY,
|
|
R, I, Refresh,
|
|
|
|
IFF1, IFF2, IM,
|
|
|
|
MemPtr
|
|
};
|
|
|
|
/*
|
|
Flags as defined on the Z80; can be used to decode the result of getting or setting @c Flags.
|
|
*/
|
|
enum Flag: uint8_t {
|
|
Sign = 0x80,
|
|
Zero = 0x40,
|
|
Bit5 = 0x20,
|
|
HalfCarry = 0x10,
|
|
Bit3 = 0x08,
|
|
Parity = 0x04,
|
|
Overflow = 0x04,
|
|
Subtract = 0x02,
|
|
Carry = 0x01
|
|
};
|
|
|
|
/*!
|
|
Subclasses will be given the task of performing partial machine cycles, allowing them to provide whatever interface they like
|
|
between a Z80 and the rest of the system. @c PartialMachineCycle defines the information they will be handed for each unit
|
|
of execution.
|
|
*/
|
|
struct PartialMachineCycle {
|
|
enum Operation {
|
|
/// The final half cycle of the opcode fetch part of an M1 cycle.
|
|
ReadOpcode = 0,
|
|
/// The 1.5 cycles of a read cycle.
|
|
Read,
|
|
/// The 1.5 cycles of a write cycle.
|
|
Write,
|
|
/// The 1.5 cycles of an input cycle.
|
|
Input,
|
|
/// The 1.5 cycles of an output cycle.
|
|
Output,
|
|
/// The 1.5 cycles of an interrupt acknowledgment.
|
|
Interrupt,
|
|
|
|
/// The two-cycle refresh part of an M1 cycle.
|
|
Refresh,
|
|
/// A period with no changes in bus signalling.
|
|
Internal,
|
|
/// A bus acknowledgement cycle.
|
|
BusAcknowledge,
|
|
|
|
/// A wait state within an M1 cycle.
|
|
ReadOpcodeWait,
|
|
/// A wait state within a read cycle.
|
|
ReadWait,
|
|
/// A wait state within a write cycle.
|
|
WriteWait,
|
|
/// A wait state within an input cycle.
|
|
InputWait,
|
|
/// A wait state within an output cycle.
|
|
OutputWait,
|
|
/// A wait state within an interrupt acknowledge cycle.
|
|
InterruptWait,
|
|
|
|
/// The first 1.5 cycles of an M1 bus cycle, up to the sampling of WAIT.
|
|
ReadOpcodeStart,
|
|
/// The first 1.5 cycles of a read cycle, up to the sampling of WAIT.
|
|
ReadStart,
|
|
/// The first 1.5 cycles of a write cycle, up to the sampling of WAIT.
|
|
WriteStart,
|
|
/// The first 1.5 samples of an input bus cycle, up to the sampling of WAIT.
|
|
InputStart,
|
|
/// The first 1.5 samples of an output bus cycle, up to the sampling of WAIT.
|
|
OutputStart,
|
|
/// The first portion of an interrupt acknowledgement — 2.5 or 3.5 cycles, depending on interrupt mode.
|
|
InterruptStart,
|
|
};
|
|
/// The operation being carried out by the Z80. See the various getters below for better classification.
|
|
const Operation operation = Operation::Internal;
|
|
/// The length of this operation.
|
|
const HalfCycles length;
|
|
/// The current value of the address bus.
|
|
const uint16_t *const address = nullptr;
|
|
/// If the Z80 is outputting to the data bus, a pointer to that value. Otherwise, a pointer to the location where the current data bus value should be placed.
|
|
uint8_t *const value = nullptr;
|
|
/// @c true if this operation is occurring only because of an external request; @c false otherwise.
|
|
const bool was_requested = false;
|
|
|
|
/*!
|
|
@returns @c true if the processor believes that the bus handler should actually do something with
|
|
the content of this PartialMachineCycle; @c false otherwise.
|
|
*/
|
|
forceinline bool expects_action() const {
|
|
return operation <= Operation::Interrupt;
|
|
}
|
|
/*!
|
|
@returns @c true if this partial machine cycle completes one of the documented full machine cycles;
|
|
@c false otherwise.
|
|
*/
|
|
forceinline bool is_terminal() const {
|
|
return operation <= Operation::BusAcknowledge;
|
|
}
|
|
/*!
|
|
@returns @c true if this partial machine cycle is a wait cycle; @c false otherwise.
|
|
*/
|
|
forceinline bool is_wait() const {
|
|
return operation >= Operation::ReadOpcodeWait && operation <= Operation::InterruptWait;
|
|
}
|
|
/*!
|
|
@returns @c true if this partial machine cycle is a memory access; @c false otherwise.
|
|
*/
|
|
forceinline bool is_memory_access() const {
|
|
return operation <= Operation::Write;
|
|
}
|
|
|
|
enum Line {
|
|
CLK = 1 << 0,
|
|
|
|
MREQ = 1 << 1,
|
|
IOREQ = 1 << 2,
|
|
|
|
RD = 1 << 3,
|
|
WR = 1 << 4,
|
|
RFSH = 1 << 5,
|
|
|
|
M1 = 1 << 6,
|
|
|
|
BUSACK = 1 << 7,
|
|
};
|
|
|
|
/// @returns A C-style array of the bus state at the beginning of each half cycle in this
|
|
/// partial machine cycle. Each element is a combination of bit masks from the Line enum;
|
|
/// bit set means line active, bit clear means line inactive. For the CLK line set means high.
|
|
///
|
|
/// @discussion This discrete sampling is prone to aliasing errors. Beware.
|
|
const uint8_t *bus_state() const {
|
|
switch(operation) {
|
|
|
|
//
|
|
// M1 cycle
|
|
//
|
|
|
|
case Operation::ReadOpcodeStart: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK | Line::M1,
|
|
Line::M1 | Line::MREQ | Line::RD,
|
|
Line::CLK | Line::M1 | Line::MREQ | Line::RD,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::ReadOpcode:
|
|
case Operation::ReadOpcodeWait: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::M1 | Line::MREQ | Line::RD,
|
|
Line::CLK | Line::M1 | Line::MREQ | Line::RD,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::Refresh: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK | Line::RFSH | Line::MREQ,
|
|
Line::RFSH,
|
|
Line::CLK | Line::RFSH | Line::MREQ,
|
|
Line::RFSH | Line::MREQ,
|
|
Line::CLK | Line::RFSH,
|
|
Line::RFSH,
|
|
Line::CLK | Line::RFSH,
|
|
Line::RFSH,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// Read cycle.
|
|
//
|
|
|
|
case Operation::ReadStart: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK,
|
|
Line::RD | Line::MREQ,
|
|
Line::CLK | Line::RD | Line::MREQ,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::ReadWait: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::MREQ | Line::RD,
|
|
Line::CLK | Line::MREQ | Line::RD,
|
|
Line::MREQ | Line::RD,
|
|
Line::CLK | Line::MREQ | Line::RD,
|
|
Line::MREQ | Line::RD,
|
|
Line::CLK | Line::MREQ | Line::RD,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::Read: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::MREQ | Line::RD,
|
|
Line::CLK | Line::MREQ | Line::RD,
|
|
0,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// Write cycle.
|
|
//
|
|
|
|
case Operation::WriteStart: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK,
|
|
Line::MREQ,
|
|
Line::CLK | Line::MREQ,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::WriteWait: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::MREQ,
|
|
Line::CLK | Line::MREQ,
|
|
Line::MREQ,
|
|
Line::CLK | Line::MREQ,
|
|
Line::MREQ,
|
|
Line::CLK | Line::MREQ,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::Write: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::MREQ | Line::WR,
|
|
Line::CLK | Line::MREQ | Line::WR,
|
|
0,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// Input cycle.
|
|
//
|
|
|
|
case Operation::InputStart: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK,
|
|
0,
|
|
Line::CLK | Line::IOREQ | Line::RD,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::InputWait: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::IOREQ | Line::RD,
|
|
Line::CLK | Line::IOREQ | Line::RD,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::Input: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::IOREQ | Line::RD,
|
|
Line::CLK | Line::IOREQ | Line::RD,
|
|
0,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// Output cycle.
|
|
//
|
|
|
|
case Operation::OutputStart: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK,
|
|
0,
|
|
Line::CLK | Line::IOREQ | Line::WR,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::OutputWait: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::IOREQ | Line::WR,
|
|
Line::CLK | Line::IOREQ | Line::WR,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
case Operation::Output: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::IOREQ | Line::WR,
|
|
Line::CLK | Line::IOREQ | Line::WR,
|
|
0,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// TODO: Interrupt acknowledge.
|
|
//
|
|
|
|
//
|
|
// Bus acknowldge.
|
|
//
|
|
|
|
case Operation::BusAcknowledge: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK | Line::BUSACK,
|
|
Line::BUSACK,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
//
|
|
// Internal.
|
|
//
|
|
|
|
case Operation::Internal: {
|
|
static constexpr uint8_t states[] = {
|
|
Line::CLK, 0,
|
|
Line::CLK, 0,
|
|
Line::CLK, 0,
|
|
Line::CLK, 0,
|
|
Line::CLK, 0,
|
|
};
|
|
return states;
|
|
}
|
|
|
|
default: break;
|
|
}
|
|
|
|
return nullptr;
|
|
}
|
|
|
|
PartialMachineCycle(const PartialMachineCycle &rhs) noexcept;
|
|
PartialMachineCycle(Operation operation, HalfCycles length, uint16_t *address, uint8_t *value, bool was_requested) noexcept;
|
|
PartialMachineCycle() noexcept;
|
|
};
|
|
|
|
/*!
|
|
A class providing empty implementations of the methods a Z80 uses to access the bus. To wire the Z80 to a bus,
|
|
machines should subclass BusHandler and then declare a realisation of the Z80 template, supplying their bus
|
|
handler.
|
|
*/
|
|
class BusHandler {
|
|
public:
|
|
/*!
|
|
Announces that the Z80 has performed the partial machine cycle defined by @c cycle.
|
|
|
|
@returns The number of additional HalfCycles that passed in objective time while this Z80 operation was ongoing.
|
|
On an archetypal machine this will be HalfCycles(0) but some architectures may choose not to clock the Z80
|
|
during some periods or may impose wait states so predictably that it's more efficient just to add them
|
|
via this mechanism.
|
|
*/
|
|
HalfCycles perform_machine_cycle([[maybe_unused]] const PartialMachineCycle &cycle) {
|
|
return HalfCycles(0);
|
|
}
|
|
};
|
|
|
|
#include "Implementation/Z80Storage.hpp"
|
|
|
|
/*!
|
|
A base class from which the Z80 descends; separated for implementation reasons only.
|
|
*/
|
|
class ProcessorBase: public ProcessorStorage {
|
|
public:
|
|
/*!
|
|
Gets the value of a register.
|
|
|
|
@see set_value_of
|
|
|
|
@param r The register to set.
|
|
@returns The value of the register. 8-bit registers will be returned as unsigned.
|
|
*/
|
|
uint16_t value_of(Register r) const;
|
|
|
|
/*!
|
|
Sets the value of a register.
|
|
|
|
@see value_of
|
|
|
|
@param r The register to set.
|
|
@param value The value to set. If the register is only 8 bit, the value will be truncated.
|
|
*/
|
|
void set_value_of(Register r, uint16_t value);
|
|
|
|
/*!
|
|
Gets the value of the HALT output line.
|
|
*/
|
|
inline bool get_halt_line() const;
|
|
|
|
/*!
|
|
Sets the logical value of the interrupt line.
|
|
|
|
@param offset If called while within perform_machine_cycle this may be a value indicating
|
|
how many cycles before now the line changed state. The value may not be longer than the
|
|
current machine cycle. If called at any other time, this must be zero.
|
|
*/
|
|
inline void set_interrupt_line(bool value, HalfCycles offset = 0);
|
|
|
|
/*!
|
|
Gets the value of the interrupt line.
|
|
*/
|
|
inline bool get_interrupt_line() const;
|
|
|
|
/*!
|
|
Sets the logical value of the non-maskable interrupt line.
|
|
|
|
@param offset See discussion in set_interrupt_line.
|
|
*/
|
|
inline void set_non_maskable_interrupt_line(bool value, HalfCycles offset = 0);
|
|
|
|
/*!
|
|
Gets the value of the non-maskable interrupt line.
|
|
*/
|
|
inline bool get_non_maskable_interrupt_line() const;
|
|
|
|
/*!
|
|
Sets the logical value of the reset line.
|
|
*/
|
|
inline void set_reset_line(bool value);
|
|
|
|
/*!
|
|
Gets whether the Z80 would reset at the next opportunity.
|
|
|
|
@returns @c true if the line is logically active; @c false otherwise.
|
|
*/
|
|
bool get_is_resetting() const;
|
|
|
|
/*!
|
|
This emulation automatically sets itself up in power-on state at creation, which has the effect of triggering a
|
|
reset at the first opportunity. Use @c reset_power_on to disable that behaviour.
|
|
*/
|
|
void reset_power_on();
|
|
|
|
/*!
|
|
@returns @c true if the Z80 is currently beginning to fetch a new instruction; @c false otherwise.
|
|
|
|
This is not a speedy operation.
|
|
*/
|
|
bool is_starting_new_instruction() const;
|
|
};
|
|
|
|
/*!
|
|
@abstact Template providing emulation of a Z80 processor.
|
|
|
|
@discussion Users should provide as the first template parameter a subclass of CPU::Z80::BusHandler; the Z80
|
|
will announce its activity via the bus handler, which is responsible for marrying it to a bus. Users
|
|
can also nominate whether the processor includes support for the bus request and/or wait lines. Declining to
|
|
support either can produce a minor runtime performance improvement.
|
|
*/
|
|
template <class T, bool uses_bus_request, bool uses_wait_line> class Processor: public ProcessorBase {
|
|
public:
|
|
Processor(T &bus_handler);
|
|
|
|
/*!
|
|
Runs the Z80 for a supplied number of cycles.
|
|
|
|
@discussion Subclasses must implement @c perform_machine_cycle(const PartialMachineCycle &cycle) .
|
|
|
|
If it is a read operation then @c value will be seeded with the value 0xff.
|
|
|
|
@param cycles The number of cycles to run for.
|
|
*/
|
|
void run_for(const HalfCycles cycles);
|
|
|
|
/*!
|
|
Sets the logical value of the bus request line, having asserted that this Z80 supports the bus request line.
|
|
*/
|
|
void set_bus_request_line(bool value);
|
|
|
|
/*!
|
|
Gets the logical value of the bus request line.
|
|
*/
|
|
bool get_bus_request_line() const;
|
|
|
|
/*!
|
|
Sets the logical value of the wait line, having asserted that this Z80 supports the wait line.
|
|
*/
|
|
void set_wait_line(bool value);
|
|
|
|
/*!
|
|
Gets the logical value of the bus request line.
|
|
*/
|
|
bool get_wait_line() const;
|
|
|
|
private:
|
|
T &bus_handler_;
|
|
|
|
void assemble_page(InstructionPage &target, InstructionTable &table, bool add_offsets);
|
|
void copy_program(const MicroOp *source, std::vector<MicroOp> &destination);
|
|
};
|
|
|
|
#include "Implementation/Z80Implementation.hpp"
|
|
|
|
}
|