/* * mos6502.dis.c * * Disassembly of the mos6502 machine code into an assembly notation. */ #include #include "mos6502.h" #include "mos6502.dis.h" #include "mos6502.enums.h" static vm_8bit jump_table[MOS6502_MEMSIZE]; static char *instruction_strings[] = { "ADC", "AND", "ASL", "BCC", "BCS", "BEQ", "BIT", "BMI", "BNE", "BPL", "BRK", "BVC", "BVS", "CLC", "CLD", "CLI", "CLV", "CMP", "CPX", "CPY", "DEC", "DEX", "DEY", "EOR", "INC", "INX", "INY", "JMP", "JSR", "LDA", "LDX", "LDY", "LSR", "NOP", "ORA", "PHA", "PHP", "PLA", "PLP", "ROL", "ROR", "RTI", "RTS", "SBC", "SEC", "SED", "SEI", "STA", "STX", "STY", "TAX", "TAY", "TSX", "TXA", "TXS", "TYA", }; /* * Given a stream, address mode and 16-bit value, print the value out in * the form that is expected given the address mode. The value is not * necessarily going to truly be 16-bit; most address modes use one * 8-bit operand. But we can contain all possible values with the 16-bit * type. */ void mos6502_dis_operand(FILE *stream, int address, int addr_mode, vm_16bit value) { int rel_address; switch (addr_mode) { case ACC: break; case ABS: fprintf(stream, "$%04X", value); break; case ABX: fprintf(stream, "$%04X,X", value); break; case ABY: fprintf(stream, "$%04X,Y", value); break; case IMM: fprintf(stream, "#$%02X", value); break; case IMP: break; case IND: if (jump_table[value]) { mos6502_dis_label(stream, value); } else { fprintf(stream, "($%04X)", value); } break; case IDX: fprintf(stream, "($%02X,X)", value); break; case IDY: fprintf(stream, "($%02X),Y", value); break; case REL: rel_address = address + value; if (value > 127) { rel_address -= 256; } mos6502_dis_label(stream, rel_address); break; case ZPG: fprintf(stream, "$%02X", value); break; case ZPX: fprintf(stream, "$%02X,X", value); break; case ZPY: fprintf(stream, "$%02X,Y", value); break; } } /* * This function will write to the stream the instruction that the given * opcode maps to. */ void mos6502_dis_instruction(FILE *stream, int inst_code) { // Arguably this could or should be done as fputs(), which is // presumably a simpler output method. But, since we use fprintf() // in other places, I think we should continue to do so. Further, we // use a simple format string (%s) to avoid the linter's complaints // about potential security issues. fprintf(stream, "%s", instruction_strings[inst_code]); } /* * This function returns the number of bytes that the given opcode is * expecting to work with. For instance, if the opcode is in absolute * address mode, then we will need to read the next two bytes in the * stream to compose a full 16-bit address to work with. If our opcode * is in immediate mode, then we only need to read one byte. Many * opcodes will read no bytes at all from the stream (in which we return * zero). */ int mos6502_dis_expected_bytes(int addr_mode) { switch (addr_mode) { // These are 16-bit operands, because they work with absolute // addresses in memory. case ABS: case ABY: case ABX: case IND: return 2; // These are the 8-bit operand address modes. case IMM: case IDX: case IDY: case REL: case ZPG: case ZPX: case ZPY: return 1; // These two address modes have implied arguments; ACC is // the accumulator, and IMP basically means it operates on // some specific (presumably obvious) thing and no operand // is necessary. case ACC: case IMP: return 0; } // I don't know how we got here, outside of foul magicks and cruel // trickery. Let's fearfully return zero! return 0; } /* * Scan the segment (with a given address) and write the opcode at that * point to the given file stream. This function will also write an * operand to the file stream if one is warranted. We return the number * of bytes consumed by scanning past the opcode and/or operand. */ int mos6502_dis_opcode(FILE *stream, vm_segment *segment, int address) { vm_8bit opcode; vm_16bit operand; int addr_mode; int inst_code; int expected; // The next byte is assumed to be the opcode we work with. opcode = vm_segment_get(segment, address); // And given that opcode, we need to see how many bytes large our // operand will be. addr_mode = mos6502_addr_mode(opcode); expected = mos6502_dis_expected_bytes(addr_mode); // The specific instruction we mean to execute inst_code = mos6502_instruction(opcode); // The operand itself defaults to zero... in cases where this // doesn't change, the instruction related to the opcode will // probably not even use it. operand = 0; // And we need to skip ahead of the opcode. address++; switch (expected) { case 2: // If we have a two-byte operand, then the first byte is the // MSB and our operand will need to shift it 8 positions to // the left before it can be OR'd. operand |= vm_segment_get(segment, address) << 8; address++; // Note we fall through here to the next case... case 1: // If it's a one-byte operand, then this byte should occupy // the LSB space which simply requires we OR the byte // directly in. If this is part of a two-byte operand, then // the same logic still applies. operand |= vm_segment_get(segment, address); address++; // And, in any other case (e.g. 0), we are done; we don't // read anything, and we leave the operand as it is. default: break; } // If the stream is NULL, we're doing some kind of lookahead. // Furthermore, if this is an instruction that would switch control // to a different spot in the program, then let's label this in the // jump table. if (stream == NULL && mos6502_would_jump(inst_code)) { mos6502_dis_jump_label(operand, address, addr_mode); } // It's totally possible that we are not expected to print out the // contents of our inspection of the opcode. (For example, we may // just want to set the jump table in a lookahead operation.) if (stream) { // Hey! We might have a label at this position in the code. If // so, let's print out the label. if (jump_table[address]) { // This will print out just the label itself. mos6502_dis_label(stream, address); // But to actually define the label, we need a colon to // complete the notation. (We don't _need_ a newline, but it // looks nicer to my arbitrary sensibilities. Don't @ me!) fprintf(stream, ":\n"); } // Let's print out to the stream what we have so far. First, we // indent by four spaces. fprintf(stream, " "); // Print out the instruction code that our opcode represents. mos6502_dis_instruction(stream, inst_code); if (expected) { // Let's "tab" over; each instruction code is 3 characters, so let's // move over 5 spaces (4 spaces indent + 1, just to keep everything // aligned by 4-character boundaries). fprintf(stream, " "); // Print out the operand given the proper address mode. mos6502_dis_operand(stream, address, addr_mode, operand); } // And let's terminate the line. fprintf(stream, "\n"); } // The expected number of bytes here is for the operand, but we need // to add one for the opcode to return the true number that this // opcode sequence would consume. return expected + 1; } void mos6502_dis_scan(FILE *stream, vm_segment *segment, int pos, int end) { while (pos < end) { pos += mos6502_dis_opcode(stream, segment, pos); } } void mos6502_dis_jump_label(vm_16bit operand, int address, int addr_mode) { int jump_loc = operand; if (addr_mode == REL) { jump_loc = address + operand; if (operand > 127) { jump_loc -= 256; } } jump_table[jump_loc] = 1; } inline void mos6502_dis_label(FILE *stream, int address) { fprintf(stream, "ADDR_%d", address); } inline void mos6502_dis_jump_unlabel(int address) { jump_table[address] = 0; } inline bool mos6502_dis_is_jump_label(int address) { return jump_table[address] == 1; }