added calibration BASIC program
This commit is contained in:
parent
f1c346c3a9
commit
49ec8d22d8
@ -19,7 +19,7 @@ Calibration
|
||||
|
||||
This BASIC program is helpful in calibrating the RetroConnector Joystick Interface board. Type this in at the BASIC prompt on your Apple II:
|
||||
|
||||
10 print pdl(0) " " pdl(1) " " peek(-16287) " " peek(-16286)
|
||||
10 print pdl(0) " " pdl(1)
|
||||
20 goto 10
|
||||
|
||||
Then type *RUN* and hit enter.
|
||||
@ -28,3 +28,9 @@ While the resulting numbers scroll down the screen, use a small screwdriver to a
|
||||
|
||||
Most Apple II programs allow for a certain "dead zone" in the middle of the joystick values, so it's not necessary to be precisely 127 at center.
|
||||
|
||||
To test buttons along with joystick calibration, the above program can be adjusted so:
|
||||
|
||||
10 print pdl(0) " " pdl(1) " " peek(-16287) " " peek(-16286)
|
||||
20 goto 10
|
||||
|
||||
The last two values are button 1 and 2. When pressed, they should be *above* 127, when released, *below* 127.
|