diff --git a/CHANGES.md b/CHANGES.md new file mode 100644 index 0000000..9dcdd88 --- /dev/null +++ b/CHANGES.md @@ -0,0 +1,13 @@ +# 1.3.2 + +Move External LED connector closer to edge to clear cable plugged in to J1. + +Change footprint of D3/D4 to "Diode_SMD:D_SOD-123". + +Increase width of 12V and 5V traces. + +Move SD Card 3.3v trace to bottom. + +Slightly move screw terminal offset to avoid clipped silkscreen warning. + +# Older changes not recorded diff --git a/kicad/bluescsi_iigs_internal.kicad_pcb b/kicad/bluescsi_iigs_internal.kicad_pcb index 749bfe8..7377bee 100644 --- a/kicad/bluescsi_iigs_internal.kicad_pcb +++ b/kicad/bluescsi_iigs_internal.kicad_pcb @@ -29,6 +29,19 @@ ) (setup + (stackup + (layer "F.SilkS" (type "Top Silk Screen")) + (layer "F.Paste" (type "Top Solder Paste")) + (layer "F.Mask" (type "Top Solder Mask") (thickness 0.01)) + (layer "F.Cu" (type "copper") (thickness 0.035)) + (layer "dielectric 1" (type "core") (thickness 1.51) (material "FR4") (epsilon_r 4.5) (loss_tangent 0.02)) + (layer "B.Cu" (type "copper") (thickness 0.035)) + (layer "B.Mask" (type "Bottom Solder Mask") (thickness 0.01)) + (layer "B.Paste" (type "Bottom Solder Paste")) + (layer "B.SilkS" (type "Bottom Silk Screen")) + (copper_finish "None") + (dielectric_constraints no) + ) (pad_to_mask_clearance 0) (pcbplotparams (layerselection 0x0001cfc_ffffffff) @@ -126,7 +139,7 @@ (at 152.4 50.8) (descr "Through hole headers for BluePill module. No SWD breakout. Fancy silkscreen.") (tags "module BlluePill Blue Pill header SWD breakout") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000605fe9fd") (attr through_hole) @@ -306,7 +319,7 @@ (tedit 5A02FC95) (tstamp 00000000-0000-0000-0000-000060601a98) (at 183.896 61.595 90) (descr "Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006062fc1a") (attr smd) @@ -374,7 +387,7 @@ (at 177.927 89.408 180) (descr "Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator") (tags "resistor handsolder") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060634bdc") (attr smd) @@ -416,11 +429,11 @@ (at 184.531 84.836 -90) (descr "LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator") (tags "LED handsolder") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060632077") (attr smd) - (fp_text reference "D1" (at 0 1.651 90) (layer "F.SilkS") + (fp_text reference "D1" (at 0 2.032) (layer "F.SilkS") (effects (font (size 1 1) (thickness 0.15))) (tstamp 2454fd1b-3484-4838-8b7e-d26357238fe1) ) @@ -455,98 +468,100 @@ ) ) - (footprint "Diode_SMD:D_SOD-323_HandSoldering" (layer "F.Cu") - (tedit 58641869) (tstamp 00000000-0000-0000-0000-0000608620eb) - (at 138.43 97.155 180) - (descr "SOD-323") - (tags "SOD-323") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (footprint "Diode_SMD:D_SOD-123" (layer "F.Cu") + (tedit 58645DC7) (tstamp 00000000-0000-0000-0000-0000608620eb) + (at 139.7 97.155 180) + (descr "SOD-123") + (tags "SOD-123") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006086ef1b") (attr smd) - (fp_text reference "D4" (at -3.302 -0.127) (layer "F.SilkS") + (fp_text reference "D4" (at -3.302 0.127 180) (layer "F.SilkS") (effects (font (size 1 1) (thickness 0.15))) - (tstamp 9193c41e-d425-447d-b95c-6986d66ea01c) + (tstamp 14d6d401-a404-4c2f-a8da-d54e532483d5) ) - (fp_text value "1N4001" (at 0.1 1.9) (layer "F.Fab") + (fp_text value "1N5319" (at 0 2.1 180) (layer "F.Fab") (effects (font (size 1 1) (thickness 0.15))) - (tstamp 27d56953-c620-4d5b-9c1c-e48bc3d9684a) + (tstamp 58b71f6a-7870-440f-ba6c-8a5a5a6ec42c) ) - (fp_text user "${REFERENCE}" (at 0 -1.85) (layer "F.Fab") + (fp_text user "${REFERENCE}" (at 0 -2 180) (layer "F.Fab") (effects (font (size 1 1) (thickness 0.15))) - (tstamp bd9595a1-04f3-4fda-8f1b-e65ad874edd3) + (tstamp 2a40d7ce-d85e-418d-a4ed-5e864513b349) ) - (fp_line (start -1.9 0.85) (end 1.25 0.85) (layer "F.SilkS") (width 0.12) (tstamp 6fd4442e-30b3-428b-9306-61418a63d311)) - (fp_line (start -1.9 -0.85) (end 1.25 -0.85) (layer "F.SilkS") (width 0.12) (tstamp 8d0c1d66-35ef-4a53-a28f-436a11b54f42)) - (fp_line (start -1.9 -0.85) (end -1.9 0.85) (layer "F.SilkS") (width 0.12) (tstamp be645d0f-8568-47a0-a152-e3ddd33563eb)) - (fp_line (start -2 0.95) (end 2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp 29e058a7-50a3-43e5-81c3-bfee53da08be)) - (fp_line (start -2 -0.95) (end -2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp 3fd54105-4b7e-4004-9801-76ec66108a22)) - (fp_line (start 2 -0.95) (end 2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp 5cf2db29-f7ab-499a-9907-cdeba64bf0f3)) - (fp_line (start -2 -0.95) (end 2 -0.95) (layer "F.CrtYd") (width 0.05) (tstamp feb26ecb-9193-46ea-a41b-d09305bf0a3e)) - (fp_line (start -0.9 0.7) (end -0.9 -0.7) (layer "F.Fab") (width 0.1) (tstamp 0ce8d3ab-2662-4158-8a2a-18b782908fc5)) - (fp_line (start 0.9 -0.7) (end 0.9 0.7) (layer "F.Fab") (width 0.1) (tstamp 0e8f7fc0-2ef2-4b90-9c15-8a3a601ee459)) - (fp_line (start -0.3 -0.35) (end -0.3 0.35) (layer "F.Fab") (width 0.1) (tstamp 29195ea4-8218-44a1-b4bf-466bee0082e4)) - (fp_line (start -0.9 -0.7) (end 0.9 -0.7) (layer "F.Fab") (width 0.1) (tstamp 382ca670-6ae8-4de6-90f9-f241d1337171)) - (fp_line (start 0.9 0.7) (end -0.9 0.7) (layer "F.Fab") (width 0.1) (tstamp b0906e10-2fbc-4309-a8b4-6fc4cd1a5490)) - (fp_line (start 0.2 0.35) (end -0.3 0) (layer "F.Fab") (width 0.1) (tstamp c9667181-b3c7-4b01-b8b4-baa29a9aea63)) - (fp_line (start -0.3 0) (end 0.2 -0.35) (layer "F.Fab") (width 0.1) (tstamp cff34251-839c-4da9-a0ad-85d0fc4e32af)) - (fp_line (start -0.3 0) (end -0.5 0) (layer "F.Fab") (width 0.1) (tstamp d0fb0864-e79b-4bdc-8e8e-eed0cabe6d56)) - (fp_line (start 0.2 -0.35) (end 0.2 0.35) (layer "F.Fab") (width 0.1) (tstamp d5b800ca-1ab6-4b66-b5f7-2dda5658b504)) - (fp_line (start 0.2 0) (end 0.45 0) (layer "F.Fab") (width 0.1) (tstamp ebd06df3-d52b-4cff-99a2-a771df6d3733)) - (pad "1" smd rect locked (at -1.25 0 180) (size 1 1) (layers "F.Cu" "F.Paste" "F.Mask") - (net 13 "GND") (pinfunction "K") (pintype "passive") (tstamp 8c0807a7-765b-4fa5-baaa-e09a2b610e6b)) - (pad "2" smd rect locked (at 1.25 0 180) (size 1 1) (layers "F.Cu" "F.Paste" "F.Mask") - (net 46 "Net-(D4-Pad2)") (pinfunction "A") (pintype "passive") (tstamp 309b3bff-19c8-41ec-a84d-63399c649f46)) - (model "${KISYS3DMOD}/Diode_SMD.3dshapes/D_SOD-323.wrl" + (fp_line (start -2.25 -1) (end -2.25 1) (layer "F.SilkS") (width 0.12) (tstamp 00e7ec8c-e7bb-4716-b317-547f58ec5b1f)) + (fp_line (start -2.25 1) (end 1.65 1) (layer "F.SilkS") (width 0.12) (tstamp 227d236b-c8a0-4eff-96fe-36ff47a0f8e3)) + (fp_line (start -2.25 -1) (end 1.65 -1) (layer "F.SilkS") (width 0.12) (tstamp 5be6c0d7-901a-4e27-a927-45a2078858ab)) + (fp_line (start 2.35 1.15) (end -2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp 3fca4193-2b64-49c2-94f4-3d23efe235a9)) + (fp_line (start 2.35 -1.15) (end 2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp 86510ac8-7135-4dc2-b245-73b56f0c9371)) + (fp_line (start -2.35 -1.15) (end -2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp c03e62c1-05c2-4b1e-9966-090335bf09ba)) + (fp_line (start -2.35 -1.15) (end 2.35 -1.15) (layer "F.CrtYd") (width 0.05) (tstamp e66c6e4e-52ed-4336-be58-8a481d21c694)) + (fp_line (start -0.75 0) (end -0.35 0) (layer "F.Fab") (width 0.1) (tstamp 0386a8c0-7a33-40ad-8ea1-145d161c50a1)) + (fp_line (start 0.25 -0.4) (end 0.25 0.4) (layer "F.Fab") (width 0.1) (tstamp 2ed120dc-814f-48c2-8306-066a8fc8c11b)) + (fp_line (start -1.4 0.9) (end -1.4 -0.9) (layer "F.Fab") (width 0.1) (tstamp 3cc40abc-9324-4b0c-bbc4-c9383a5d7f62)) + (fp_line (start 1.4 0.9) (end -1.4 0.9) (layer "F.Fab") (width 0.1) (tstamp 42589805-d870-4e5e-a7a4-a45895232563)) + (fp_line (start -0.35 0) (end -0.35 0.55) (layer "F.Fab") (width 0.1) (tstamp 459089f5-4d3d-4635-8532-cb9674f35982)) + (fp_line (start -0.35 0) (end -0.35 -0.55) (layer "F.Fab") (width 0.1) (tstamp 90a3d2cd-5a4e-43d1-9ff6-1d9d1a26289c)) + (fp_line (start 0.25 0) (end 0.75 0) (layer "F.Fab") (width 0.1) (tstamp a8beef13-022d-47d7-8643-4c5f8bd3fea1)) + (fp_line (start -1.4 -0.9) (end 1.4 -0.9) (layer "F.Fab") (width 0.1) (tstamp afc4068f-c9a3-48c4-8a7c-725fc5a9970c)) + (fp_line (start -0.35 0) (end 0.25 -0.4) (layer "F.Fab") (width 0.1) (tstamp bef239bc-d8ba-45c6-be92-c1d9bbf2a643)) + (fp_line (start 1.4 -0.9) (end 1.4 0.9) (layer "F.Fab") (width 0.1) (tstamp eaaea3ad-1ab3-4594-894e-63ea792629a9)) + (fp_line (start 0.25 0.4) (end -0.35 0) (layer "F.Fab") (width 0.1) (tstamp ed76ed4a-9e46-4378-8f3a-4fa997271d60)) + (pad "1" smd rect (at -1.65 0 180) (size 0.9 1.2) (layers "F.Cu" "F.Paste" "F.Mask") + (net 13 "GND") (pinfunction "K") (pintype "passive") (tstamp 2ecef960-da4c-42cf-a72e-4a7cf3691990)) + (pad "2" smd rect (at 1.65 0 180) (size 0.9 1.2) (layers "F.Cu" "F.Paste" "F.Mask") + (net 46 "Net-(D4-Pad2)") (pinfunction "A") (pintype "passive") (tstamp 2157c2e1-a5cc-4885-bc22-fdf9da595931)) + (model "${KICAD6_3DMODEL_DIR}/Diode_SMD.3dshapes/D_SOD-123.wrl" (offset (xyz 0 0 0)) (scale (xyz 1 1 1)) (rotate (xyz 0 0 0)) ) ) - (footprint "Diode_SMD:D_SOD-323_HandSoldering" (layer "F.Cu") - (tedit 58641869) (tstamp 00000000-0000-0000-0000-0000608638b7) + (footprint "Diode_SMD:D_SOD-123" (layer "F.Cu") + (tedit 58645DC7) (tstamp 00000000-0000-0000-0000-0000608638b7) (at 140.716 100.33 180) - (descr "SOD-323") - (tags "SOD-323") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (descr "SOD-123") + (tags "SOD-123") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006086e55b") (attr smd) - (fp_text reference "D3" (at -3.302 0.254) (layer "F.SilkS") + (fp_text reference "D3" (at -3.302 0 180) (layer "F.SilkS") (effects (font (size 1 1) (thickness 0.15))) - (tstamp 935f462d-8b1e-4005-9f1e-17f537ab1756) + (tstamp 48f2c4d4-a567-441b-b093-907f4fd625ab) ) - (fp_text value "1N4001" (at 0.1 1.9) (layer "F.Fab") + (fp_text value "1N5319" (at 0 2.1 180) (layer "F.Fab") (effects (font (size 1 1) (thickness 0.15))) - (tstamp 0325ec43-0390-4ae2-b055-b1ec6ce17b1c) + (tstamp d05848d9-b703-4f33-927a-33e1dbd422f2) ) - (fp_text user "${REFERENCE}" (at 0 -1.85) (layer "F.Fab") + (fp_text user "${REFERENCE}" (at 0 -2 180) (layer "F.Fab") (effects (font (size 1 1) (thickness 0.15))) - (tstamp 240c10af-51b5-420e-a6f4-a2c8f5db1db5) + (tstamp 4493977a-c5ba-41d3-aae3-c78a888a1e07) ) - (fp_line (start -1.9 -0.85) (end -1.9 0.85) (layer "F.SilkS") (width 0.12) (tstamp 2d697cf0-e02e-4ed1-a048-a704dab0ee43)) - (fp_line (start -1.9 0.85) (end 1.25 0.85) (layer "F.SilkS") (width 0.12) (tstamp 576c6616-e95d-4f1e-8ead-dea30fcdc8c2)) - (fp_line (start -1.9 -0.85) (end 1.25 -0.85) (layer "F.SilkS") (width 0.12) (tstamp 7b044939-8c4d-444f-b9e0-a15fcdeb5a86)) - (fp_line (start 2 -0.95) (end 2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp 262f1ea9-0133-4b43-be36-456207ea857c)) - (fp_line (start -2 -0.95) (end -2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp 89e83c2e-e90a-4a50-b278-880bac0cfb49)) - (fp_line (start -2 0.95) (end 2 0.95) (layer "F.CrtYd") (width 0.05) (tstamp a5e521b9-814e-4853-a5ac-f158785c6269)) - (fp_line (start -2 -0.95) (end 2 -0.95) (layer "F.CrtYd") (width 0.05) (tstamp c1c799a0-3c93-493a-9ad7-8a0561bc69ee)) - (fp_line (start -0.3 0) (end -0.5 0) (layer "F.Fab") (width 0.1) (tstamp 22999e73-da32-43a5-9163-4b3a41614f25)) - (fp_line (start 0.2 0.35) (end -0.3 0) (layer "F.Fab") (width 0.1) (tstamp 40b14a16-fb82-4b9d-89dd-55cd98abb5cc)) - (fp_line (start 0.9 -0.7) (end 0.9 0.7) (layer "F.Fab") (width 0.1) (tstamp 5edcefbe-9766-42c8-9529-28d0ec865573)) - (fp_line (start 0.2 -0.35) (end 0.2 0.35) (layer "F.Fab") (width 0.1) (tstamp 658dad07-97fd-466c-8b49-21892ac96ea4)) - (fp_line (start -0.3 0) (end 0.2 -0.35) (layer "F.Fab") (width 0.1) (tstamp 6e68f0cd-800e-4167-9553-71fc59da1eeb)) - (fp_line (start -0.9 -0.7) (end 0.9 -0.7) (layer "F.Fab") (width 0.1) (tstamp 721d1be9-236e-470b-ba69-f1cc6c43faf9)) - (fp_line (start -0.9 0.7) (end -0.9 -0.7) (layer "F.Fab") (width 0.1) (tstamp 81a15393-727e-448b-a777-b18773023d89)) - (fp_line (start -0.3 -0.35) (end -0.3 0.35) (layer "F.Fab") (width 0.1) (tstamp a4f86a46-3bc8-4daa-9125-a63f297eb114)) - (fp_line (start 0.2 0) (end 0.45 0) (layer "F.Fab") (width 0.1) (tstamp c09938fd-06b9-4771-9f63-2311626243b3)) - (fp_line (start 0.9 0.7) (end -0.9 0.7) (layer "F.Fab") (width 0.1) (tstamp ec5c2062-3a41-4636-8803-069e60a1641a)) - (pad "1" smd rect locked (at -1.25 0 180) (size 1 1) (layers "F.Cu" "F.Paste" "F.Mask") - (net 12 "+5V") (pinfunction "K") (pintype "passive") (tstamp 592f25e6-a01b-47fd-8172-3da01117d00a)) - (pad "2" smd rect locked (at 1.25 0 180) (size 1 1) (layers "F.Cu" "F.Paste" "F.Mask") - (net 51 "/REG_OUT") (pinfunction "A") (pintype "passive") (tstamp 503dbd88-3e6b-48cc-a2ea-a6e28b52a1f7)) - (model "${KISYS3DMOD}/Diode_SMD.3dshapes/D_SOD-323.wrl" + (fp_line (start -2.25 -1) (end 1.65 -1) (layer "F.SilkS") (width 0.12) (tstamp 400ae9a8-defa-4428-993d-d331f4c802a6)) + (fp_line (start -2.25 -1) (end -2.25 1) (layer "F.SilkS") (width 0.12) (tstamp 6ff2874f-e693-46ee-9e7b-44354f6e5884)) + (fp_line (start -2.25 1) (end 1.65 1) (layer "F.SilkS") (width 0.12) (tstamp 7763ef0b-f541-4d0b-a22e-baccd8a596e4)) + (fp_line (start -2.35 -1.15) (end 2.35 -1.15) (layer "F.CrtYd") (width 0.05) (tstamp 2b12877d-582c-4c5d-9e81-fa9198027b46)) + (fp_line (start 2.35 -1.15) (end 2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp 349eabd2-9157-4e6f-84c8-33beed084473)) + (fp_line (start 2.35 1.15) (end -2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp 90a74f5e-7380-4ff0-bb5e-d9d5841f174b)) + (fp_line (start -2.35 -1.15) (end -2.35 1.15) (layer "F.CrtYd") (width 0.05) (tstamp bd8354e6-6367-4dcd-aa20-50a90c915d71)) + (fp_line (start 0.25 0) (end 0.75 0) (layer "F.Fab") (width 0.1) (tstamp 233a4b12-75f8-4e6b-bef8-914a0a26e0cb)) + (fp_line (start -1.4 0.9) (end -1.4 -0.9) (layer "F.Fab") (width 0.1) (tstamp 27eec292-db7f-4d26-82a8-8d97acc6ba2b)) + (fp_line (start 1.4 -0.9) (end 1.4 0.9) (layer "F.Fab") (width 0.1) (tstamp 319a09d2-d88d-4f15-9d48-0f9d02f51cda)) + (fp_line (start -0.35 0) (end -0.35 -0.55) (layer "F.Fab") (width 0.1) (tstamp 3e60af89-5f8f-4d22-8823-3189b72e486e)) + (fp_line (start 0.25 0.4) (end -0.35 0) (layer "F.Fab") (width 0.1) (tstamp 77e5169f-0ea3-4de8-adfb-6176e496a736)) + (fp_line (start -1.4 -0.9) (end 1.4 -0.9) (layer "F.Fab") (width 0.1) (tstamp 918528f9-3820-428a-a8cd-9221af4c06a3)) + (fp_line (start -0.35 0) (end 0.25 -0.4) (layer "F.Fab") (width 0.1) (tstamp 9e7b24eb-f1b1-49fc-8e4a-221a18c1e299)) + (fp_line (start 1.4 0.9) (end -1.4 0.9) (layer "F.Fab") (width 0.1) (tstamp bbdc68c7-50a5-452a-887e-b80055ad1157)) + (fp_line (start -0.75 0) (end -0.35 0) (layer "F.Fab") (width 0.1) (tstamp df93d791-8a79-437a-b5ea-e96d471e8093)) + (fp_line (start 0.25 -0.4) (end 0.25 0.4) (layer "F.Fab") (width 0.1) (tstamp ef9ab9de-65de-453b-92d1-8911d65e0733)) + (fp_line (start -0.35 0) (end -0.35 0.55) (layer "F.Fab") (width 0.1) (tstamp fe9155f7-7886-4354-aff3-85fd3939a5be)) + (pad "1" smd rect (at -1.65 0 180) (size 0.9 1.2) (layers "F.Cu" "F.Paste" "F.Mask") + (net 12 "+5V") (pinfunction "K") (pintype "passive") (tstamp 38e40ecc-0b74-4360-b05d-5535ecf737f5)) + (pad "2" smd rect (at 1.65 0 180) (size 0.9 1.2) (layers "F.Cu" "F.Paste" "F.Mask") + (net 51 "/REG_OUT") (pinfunction "A") (pintype "passive") (tstamp cd6bb9a6-42c6-4a03-bda5-c16581b40e6d)) + (model "${KICAD6_3DMODEL_DIR}/Diode_SMD.3dshapes/D_SOD-123.wrl" (offset (xyz 0 0 0)) (scale (xyz 1 1 1)) (rotate (xyz 0 0 0)) @@ -558,7 +573,7 @@ (at 175.133 66.548) (descr "SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open, labeled with numbers") (tags "solder jumper open") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000608b8dee") (attr exclude_from_pos_files) @@ -599,7 +614,7 @@ (at 175.133 61.722) (descr "SMD Solder Jumper, 1x1.5mm Pads, 0.3mm gap, open, labeled with numbers") (tags "solder jumper open") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000608b8175") (attr exclude_from_pos_files) @@ -640,7 +655,7 @@ (at 177.927 85.725) (descr "Resistor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 72, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator") (tags "resistor handsolder") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000606332e3") (attr smd) @@ -648,7 +663,7 @@ (effects (font (size 1 1) (thickness 0.15))) (tstamp ea6fde00-59dc-4a79-a647-7e38199fae0e) ) - (fp_text value "470" (at 0 1.65) (layer "F.Fab") + (fp_text value "110" (at 0 1.65) (layer "F.Fab") (effects (font (size 1 1) (thickness 0.15))) (tstamp f73b5500-6337-4860-a114-6e307f65ec9f) ) @@ -682,7 +697,7 @@ (at 132.08 54.61) (descr "Through hole straight pin header, 2x13, 2.54mm pitch, double rows") (tags "Through hole pin header THT 2x13 2.54mm double row") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060601454") (attr through_hole) @@ -779,7 +794,7 @@ (at 142.24 54.61) (descr "Through hole straight pin header, 2x13, 2.54mm pitch, double rows") (tags "Through hole pin header THT 2x13 2.54mm double row") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006060317b") (attr through_hole) @@ -876,7 +891,7 @@ (at 134.112 95.885) (descr "Through hole straight pin header, 1x02, 2.54mm pitch, single row") (tags "Through hole pin header THT 1x02 2.54mm single row") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060864be9") (attr through_hole) @@ -920,14 +935,14 @@ (footprint "Connector_PinHeader_2.54mm:PinHeader_1x02_P2.54mm_Vertical" (layer "F.Cu") (tedit 59FED5CC) (tstamp 00000000-0000-0000-0000-0000609deea3) - (at 129.54 91.313 180) + (at 127.889 91.313 180) (descr "Through hole straight pin header, 1x02, 2.54mm pitch, single row") (tags "Through hole pin header THT 1x02 2.54mm single row") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060aa760e") (attr through_hole) - (fp_text reference "J5" (at 2.032 2.286 270) (layer "F.SilkS") + (fp_text reference "J5" (at 1.778 -1.905 270) (layer "F.SilkS") (effects (font (size 1 1) (thickness 0.15))) (tstamp 911bdcbe-493f-4e21-a506-7cbc636e2c17) ) @@ -967,8 +982,8 @@ (footprint "my library:keystone-7774" locked (layer "F.Cu") (tedit 60A1D0AA) (tstamp 00000000-0000-0000-0000-0000609e8f0c) - (at 180.721 100.561 180) - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (at 180.771 100.561 180) + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000609e5c80") (attr through_hole) @@ -997,8 +1012,8 @@ (footprint "my library:keystone-7774" locked (layer "F.Cu") (tedit 60A1D0AA) (tstamp 00000000-0000-0000-0000-0000609ea3d2) - (at 180.721 53.871 180) - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (at 180.771 53.871 180) + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000609e648b") (attr through_hole) @@ -1030,11 +1045,11 @@ (at 184.531 90.424 90) (descr "LED SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator") (tags "LED handsolder") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060631033") (attr smd) - (fp_text reference "D2" (at 0 -1.65 90) (layer "F.SilkS") + (fp_text reference "D2" (at 0 -2.032) (layer "F.SilkS") (effects (font (size 1 1) (thickness 0.15))) (tstamp 997c2f12-73ba-4c01-9ee0-42e37cbab790) ) @@ -1079,7 +1094,7 @@ (property "MANUFACTURER_PART_NUMBER" "105162-0001") (property "MOUSER_PART_NUMBER" "538-105162-0001") (property "MOUSER_PRICE-STOCK" "https://www.mouser.co.uk/ProductDetail/Molex/105162-0001?qs=1fNsfHe5VsK8daqlgKxZfQ%3D%3D") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006089b89f") (attr through_hole) @@ -1134,7 +1149,7 @@ (at 127 66.04 -90) (descr "25-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf") (tags "25-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 47.1mm") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060d17137") (attr smd) @@ -1358,7 +1373,7 @@ (at 162.56 52.832) (descr "Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator") (tags "capacitor tantalum") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000606444b6") (attr smd) @@ -1400,7 +1415,7 @@ (footprint "my library:SOIC127P600X175-16N" (layer "B.Cu") (tedit 605FF800) (tstamp 00000000-0000-0000-0000-00006060af24) (at 160.02 86.36 180) - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006065bc08") (attr through_hole) @@ -1463,7 +1478,7 @@ (at 157.48 95.377 -90) (descr "Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator") (tags "capacitor tantalum") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060643b6e") (attr smd) @@ -1507,7 +1522,7 @@ (at 162.814 95.377 -90) (descr "Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator") (tags "capacitor tantalum") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006065bbf1") (attr smd) @@ -1549,7 +1564,7 @@ (footprint "my library:SOIC127P600X175-16N" (layer "B.Cu") (tedit 605FF800) (tstamp 00000000-0000-0000-0000-00006062abe2) (at 160.02 60.96 180) - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060640d2e") (attr through_hole) @@ -1612,7 +1627,7 @@ (at 143.51 89.535 90) (descr "Fuse SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator") (tags "fuse") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-00006099ab77") (attr smd) @@ -1654,7 +1669,7 @@ (at 172.847 87.884 180) (descr "SOT-353, SC-70-5, Handsoldering") (tags "SOT-353 SC-70-5 Handsoldering") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-000060c23a85") (attr smd) @@ -1703,7 +1718,7 @@ (at 129.54 94.615 -90) (descr "TO-220-3, Horizontal, RM 2.54mm, see https://www.vishay.com/docs/66542/to-220-1.pdf") (tags "TO-220-3 Horizontal RM 2.54mm") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000608623c0") (attr through_hole) @@ -1772,7 +1787,7 @@ (at 137.16 90.17) (descr "Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator") (tags "capacitor tantalum") - (property "Sheetfile" "/Users/mnielsen/work/blue-gs/kicad/bluescsi_iigs_internal.sch") + (property "Sheetfile" "bluescsi_iigs_internal.kicad_sch") (property "Sheetname" "") (path "/00000000-0000-0000-0000-0000608634db") (attr smd) @@ -1861,13 +1876,13 @@ (gr_text "SN #" (at 178.435 81.915 90) (layer "B.SilkS") (tstamp 235067e2-1686-40fe-a9a0-61704311b2b1) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (gr_text "Blue-GS" (at 173.736 67.31 90) (layer "B.SilkS") (tstamp 34c0bee6-7425-4435-8857-d1fe8dfb6d89) + (gr_text "BlueGS" (at 173.736 67.31 90) (layer "B.SilkS") (tstamp 34c0bee6-7425-4435-8857-d1fe8dfb6d89) (effects (font (size 1.5 1.5) (thickness 0.2)) (justify mirror)) ) (gr_text "DB-25-M" (at 129.54 64.77 270) (layer "B.SilkS") (tstamp 5f31b97b-d794-46d6-bbd9-7a5638bcf704) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (gr_text "+" (at 159.512 52.705) (layer "B.SilkS") (tstamp 79451892-db6b-4999-916d-6392174ee493) + (gr_text "+" (at 159.258 52.705) (layer "B.SilkS") (tstamp 79451892-db6b-4999-916d-6392174ee493) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) (gr_text "+" (at 155.067 92.964 90) (layer "B.SilkS") (tstamp 7acd513a-187b-4936-9f93-2e521ce33ad5) @@ -1879,7 +1894,7 @@ (gr_text "WARNING: USB\npower should\nnot be used\nwhile powered\nfrom SCSI\nor Aux +12V" (at 160.02 73.66) (layer "B.SilkS") (tstamp cbde200f-1075-469a-89f8-abbdcf30e36a) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) - (gr_text "v1.3.1 (4/2022)" (at 175.895 84.836 90) (layer "B.SilkS") (tstamp e0830067-5b66-4ce1-b2d1-aaa8af20baf7) + (gr_text "v1.3.2 (10/2022)" (at 175.895 84.836 90) (layer "B.SilkS") (tstamp e0830067-5b66-4ce1-b2d1-aaa8af20baf7) (effects (font (size 1 1) (thickness 0.15)) (justify mirror)) ) (gr_text "Aux +12V Power In" (at 140.208 93.472) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-0000608695a7) @@ -1888,7 +1903,7 @@ (gr_text "Blue-GS" (at 138.43 63.5 270) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-000060919565) (effects (font (size 1.5 1.5) (thickness 0.15))) ) - (gr_text "+" (at 127.635 91.44 180) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-0000609ddb1b) + (gr_text "+" (at 130.048 91.694 180) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-0000609ddb1b) (effects (font (size 1 1) (thickness 0.15))) ) (gr_text "Internal BlueSCSI for\nApple IIGS and //e\n" (at 138.684 78.232 270) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-0000609de693) @@ -1897,7 +1912,7 @@ (gr_text "PWR" (at 186.055 87.884) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-0000609ec0c6) (effects (font (size 1 1) (thickness 0.15)) (justify right)) ) - (gr_text "External Activity LED" (at 130.87 90.043) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-000060b9b27b) + (gr_text "External Activity LED" (at 129.794 90.043) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-000060b9b27b) (effects (font (size 1 1) (thickness 0.15)) (justify left)) ) (gr_text "+" (at 183.007 88.9) (layer "F.SilkS") (tstamp 00000000-0000-0000-0000-000060c276fb) @@ -2006,47 +2021,48 @@ (style (thickness 0.15) (arrow_length 1.27) (text_position_mode 0) (extension_height 0.58642) (extension_offset 0) keep_text_aligned) ) - (segment (start 173.736 89.408) (end 170.307 85.979) (width 0.31) (layer "F.Cu") (net 12) (tstamp 2518d4ea-25cc-4e57-a0d6-8482034e7318)) - (segment (start 159.02532 62.233641) (end 161.58796 59.671001) (width 0.31) (layer "F.Cu") (net 12) (tstamp 282c8e53-3acc-42f0-a92a-6aa976b97a93)) - (segment (start 176.927 89.408) (end 173.736 89.408) (width 0.31) (layer "F.Cu") (net 12) (tstamp 4fd9bc4f-0ae3-42d4-a1b4-9fb1b2a0a7fd)) - (segment (start 161.58796 59.671001) (end 168.764001 59.671001) (width 0.31) (layer "F.Cu") (net 12) (tstamp 5f38bdb2-3657-474e-8e86-d6bb0b298110)) - (segment (start 168.764001 59.671001) (end 170.815 61.722) (width 0.31) (layer "F.Cu") (net 12) (tstamp 83c5181e-f5ee-453c-ae5c-d7256ba8837d)) - (segment (start 141.966 100.33) (end 141.966 96.555875) (width 0.31) (layer "F.Cu") (net 12) (tstamp 9db16341-dac0-4aab-9c62-7d88c111c1ce)) - (segment (start 144.541875 93.98) (end 152.4 93.98) (width 0.31) (layer "F.Cu") (net 12) (tstamp ab8b0540-9c9f-4195-88f5-7bed0b0a8ed6)) - (segment (start 141.966 96.555875) (end 144.541875 93.98) (width 0.31) (layer "F.Cu") (net 12) (tstamp b7d06af4-a5b1-447f-9b1a-8b44eb1cc204)) - (segment (start 173.579 66.675) (end 170.814998 66.675) (width 0.31) (layer "F.Cu") (net 12) (tstamp ca5b6af8-ca05-4338-b852-b51f2b49b1db)) - (segment (start 173.833 61.722) (end 170.815 61.722) (width 0.31) (layer "F.Cu") (net 12) (tstamp d72c89a6-7578-4468-964e-2a845431195f)) - (segment (start 173.833 66.421) (end 173.579 66.675) (width 0.31) (layer "F.Cu") (net 12) (tstamp ea2ea877-1ce1-4cd6-ad19-1da87f51601d)) + (segment (start 173.736 89.408) (end 170.307 85.979) (width 0.4) (layer "F.Cu") (net 12) (tstamp 2518d4ea-25cc-4e57-a0d6-8482034e7318)) + (segment (start 159.02532 62.233641) (end 161.58796 59.671001) (width 0.4) (layer "F.Cu") (net 12) (tstamp 282c8e53-3acc-42f0-a92a-6aa976b97a93)) + (segment (start 143.764 96.012) (end 145.796 93.98) (width 0.4) (layer "F.Cu") (net 12) (tstamp 4515fcae-24fb-4e0d-af9c-772b2ddb3754)) + (segment (start 176.927 89.408) (end 173.736 89.408) (width 0.4) (layer "F.Cu") (net 12) (tstamp 4fd9bc4f-0ae3-42d4-a1b4-9fb1b2a0a7fd)) + (segment (start 161.58796 59.671001) (end 168.764001 59.671001) (width 0.4) (layer "F.Cu") (net 12) (tstamp 5f38bdb2-3657-474e-8e86-d6bb0b298110)) + (segment (start 142.366 100.33) (end 143.764 98.932) (width 0.4) (layer "F.Cu") (net 12) (tstamp 80722c3d-b24b-4fed-b56f-0512f7cb4e97)) + (segment (start 168.764001 59.671001) (end 170.815 61.722) (width 0.4) (layer "F.Cu") (net 12) (tstamp 83c5181e-f5ee-453c-ae5c-d7256ba8837d)) + (segment (start 143.764 98.932) (end 143.764 96.012) (width 0.4) (layer "F.Cu") (net 12) (tstamp 84e5a9a2-8b13-4f25-9865-8ecd395bae95)) + (segment (start 145.796 93.98) (end 152.4 93.98) (width 0.4) (layer "F.Cu") (net 12) (tstamp 861a6027-a0e0-4d8e-b69e-9ef2bfc265b4)) + (segment (start 173.579 66.675) (end 170.814998 66.675) (width 0.4) (layer "F.Cu") (net 12) (tstamp ca5b6af8-ca05-4338-b852-b51f2b49b1db)) + (segment (start 173.833 61.722) (end 170.815 61.722) (width 0.4) (layer "F.Cu") (net 12) (tstamp d72c89a6-7578-4468-964e-2a845431195f)) + (segment (start 173.833 66.421) (end 173.579 66.675) (width 0.4) (layer "F.Cu") (net 12) (tstamp ea2ea877-1ce1-4cd6-ad19-1da87f51601d)) (via (at 170.815 61.722) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 12) (tstamp 0b4c0f05-c855-4742-bad2-dbf645d5842b)) (via (at 170.307 85.979) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 12) (tstamp 8bd46048-cab7-4adf-af9a-bc2710c1894c)) (via (at 159.02532 62.233641) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 12) (tstamp c67ad10d-2f75-4ec6-a139-47058f7f06b2)) (via (at 170.814998 66.675) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 12) (tstamp f699494a-77d6-4c73-bd50-29c1c1c5b879)) - (segment (start 156.718 93.9665) (end 157.7475 94.996) (width 0.31) (layer "B.Cu") (net 12) (tstamp 02f8904b-a7b2-49dd-b392-764e7e29fb51)) - (segment (start 149.86 91.44) (end 152.4 93.98) (width 0.31) (layer "B.Cu") (net 12) (tstamp 05d3e08e-e1f9-46cf-93d0-836d1306d03a)) - (segment (start 157.734 93.98) (end 152.4 93.98) (width 0.31) (layer "B.Cu") (net 12) (tstamp 12c8f4c9-cb79-4390-b96c-a717c693de17)) - (segment (start 158.4265 88.265) (end 159.004 88.8425) (width 0.31) (layer "B.Cu") (net 12) (tstamp 12f8e43c-8f83-48d3-a9b5-5f3ebc0b6c43)) - (segment (start 143.51 90.805) (end 144.145 90.805) (width 0.31) (layer "B.Cu") (net 12) (tstamp 1c052668-6749-425a-9a77-35f046c8aa39)) - (segment (start 157.545 62.865) (end 158.393961 62.865) (width 0.31) (layer "B.Cu") (net 12) (tstamp 2a6075ae-c7fa-41db-86b8-3f996740bdc2)) - (segment (start 159.004 88.8425) (end 159.004 92.71) (width 0.31) (layer "B.Cu") (net 12) (tstamp 4344bc11-e822-474b-8d61-d12211e719b1)) - (segment (start 144.78 91.44) (end 149.86 91.44) (width 0.31) (layer "B.Cu") (net 12) (tstamp 6bd46644-7209-4d4d-acd8-f4c0d045bc61)) - (segment (start 165.354 93.599) (end 165.354 91.7879) (width 0.31) (layer "B.Cu") (net 12) (tstamp 71af7b65-0e6b-402e-b1a4-b66be507b4dc)) - (segment (start 169.799 85.471) (end 170.307 85.979) (width 0.31) (layer "B.Cu") (net 12) (tstamp 799e761c-1426-40e9-a069-1f4cb353bfaa)) - (segment (start 165.354 91.7879) (end 166.9719 90.17) (width 0.31) (layer "B.Cu") (net 12) (tstamp 86e98417-f5e4-48ba-8147-ef66cc03dde6)) - (segment (start 158.393961 62.865) (end 159.02532 62.233641) (width 0.31) (layer "B.Cu") (net 12) (tstamp 8f12311d-6f4c-4d28-a5bc-d6cb462bade7)) - (segment (start 157.7475 94.996) (end 163.957 94.996) (width 0.31) (layer "B.Cu") (net 12) (tstamp 99e6b8eb-b08e-4d42-84dd-8b7f6765b7b7)) - (segment (start 170.814998 61.722002) (end 170.815 61.722) (width 0.31) (layer "B.Cu") (net 12) (tstamp aa047297-22f8-4de0-a969-0b3451b8e164)) - (segment (start 170.307 86.544685) (end 170.307 85.979) (width 0.31) (layer "B.Cu") (net 12) (tstamp b0b4c3cb-e7ea-49c0-8162-be3bbab3e4ec)) - (segment (start 169.164 87.687685) (end 170.307 86.544685) (width 0.31) (layer "B.Cu") (net 12) (tstamp b794d099-f823-4d35-9755-ca1c45247ee9)) - (segment (start 144.145 90.805) (end 144.78 91.44) (width 0.31) (layer "B.Cu") (net 12) (tstamp befdfbe5-f3e5-423b-a34e-7bba3f218536)) - (segment (start 159.004 92.71) (end 157.734 93.98) (width 0.31) (layer "B.Cu") (net 12) (tstamp db742b9e-1fed-4e0c-b783-f911ab5116aa)) - (segment (start 169.164 89.535) (end 169.164 87.687685) (width 0.31) (layer "B.Cu") (net 12) (tstamp db851147-6a1e-4d19-898c-0ba71182359b)) - (segment (start 166.9719 90.17) (end 168.529 90.17) (width 0.31) (layer "B.Cu") (net 12) (tstamp de370984-7922-4327-a0ba-7cd613995df4)) - (segment (start 169.799 67.690998) (end 169.799 85.471) (width 0.31) (layer "B.Cu") (net 12) (tstamp df3dc9a2-ba40-4c3a-87fe-61cc8e23d71b)) - (segment (start 168.529 90.17) (end 169.164 89.535) (width 0.31) (layer "B.Cu") (net 12) (tstamp e69c64f9-717d-4a97-b3df-80325ec2fa63)) - (segment (start 163.957 94.996) (end 165.354 93.599) (width 0.31) (layer "B.Cu") (net 12) (tstamp e70d061b-28f0-4421-ad15-0598604086e8)) - (segment (start 170.814998 66.675) (end 170.814998 61.722002) (width 0.31) (layer "B.Cu") (net 12) (tstamp e79c8e11-ed47-4701-ae80-a54cdb6682a5)) - (segment (start 170.814998 66.675) (end 169.799 67.690998) (width 0.31) (layer "B.Cu") (net 12) (tstamp e87a6f80-914f-4f62-9c9f-9ba62a88ee3d)) - (segment (start 157.545 88.265) (end 158.4265 88.265) (width 0.31) (layer "B.Cu") (net 12) (tstamp eaa0d51a-ee4e-4d3a-a801-bddb7027e94c)) + (segment (start 156.718 93.9665) (end 157.7475 94.996) (width 0.4) (layer "B.Cu") (net 12) (tstamp 02f8904b-a7b2-49dd-b392-764e7e29fb51)) + (segment (start 149.86 91.44) (end 152.4 93.98) (width 0.4) (layer "B.Cu") (net 12) (tstamp 05d3e08e-e1f9-46cf-93d0-836d1306d03a)) + (segment (start 143.51 90.805) (end 144.145 90.805) (width 0.4) (layer "B.Cu") (net 12) (tstamp 1c052668-6749-425a-9a77-35f046c8aa39)) + (segment (start 157.545 88.265) (end 158.4265 88.265) (width 0.4) (layer "B.Cu") (net 12) (tstamp 1e61bd1c-35cb-4f85-8742-d08e55f6d3f2)) + (segment (start 157.545 62.865) (end 158.393961 62.865) (width 0.4) (layer "B.Cu") (net 12) (tstamp 2a6075ae-c7fa-41db-86b8-3f996740bdc2)) + (segment (start 144.78 91.44) (end 149.86 91.44) (width 0.4) (layer "B.Cu") (net 12) (tstamp 6bd46644-7209-4d4d-acd8-f4c0d045bc61)) + (segment (start 165.354 93.599) (end 165.354 91.7879) (width 0.4) (layer "B.Cu") (net 12) (tstamp 71af7b65-0e6b-402e-b1a4-b66be507b4dc)) + (segment (start 158.929511 88.768011) (end 158.929511 92.784489) (width 0.4) (layer "B.Cu") (net 12) (tstamp 78b7f2dc-70e7-45d1-9710-ae98c213d6a7)) + (segment (start 158.929511 92.784489) (end 157.734 93.98) (width 0.4) (layer "B.Cu") (net 12) (tstamp 78c5ac46-225f-4778-b685-72f89112b76d)) + (segment (start 169.799 85.471) (end 170.307 85.979) (width 0.4) (layer "B.Cu") (net 12) (tstamp 799e761c-1426-40e9-a069-1f4cb353bfaa)) + (segment (start 157.734 93.98) (end 152.4 93.98) (width 0.4) (layer "B.Cu") (net 12) (tstamp 8492c905-6ca7-44dc-b3e1-65c776331872)) + (segment (start 165.354 91.7879) (end 166.9719 90.17) (width 0.4) (layer "B.Cu") (net 12) (tstamp 86e98417-f5e4-48ba-8147-ef66cc03dde6)) + (segment (start 158.393961 62.865) (end 159.02532 62.233641) (width 0.4) (layer "B.Cu") (net 12) (tstamp 8f12311d-6f4c-4d28-a5bc-d6cb462bade7)) + (segment (start 157.7475 94.996) (end 163.957 94.996) (width 0.4) (layer "B.Cu") (net 12) (tstamp 99e6b8eb-b08e-4d42-84dd-8b7f6765b7b7)) + (segment (start 170.814998 61.722002) (end 170.815 61.722) (width 0.4) (layer "B.Cu") (net 12) (tstamp aa047297-22f8-4de0-a969-0b3451b8e164)) + (segment (start 170.307 86.544685) (end 170.307 85.979) (width 0.4) (layer "B.Cu") (net 12) (tstamp b0b4c3cb-e7ea-49c0-8162-be3bbab3e4ec)) + (segment (start 169.164 87.687685) (end 170.307 86.544685) (width 0.4) (layer "B.Cu") (net 12) (tstamp b794d099-f823-4d35-9755-ca1c45247ee9)) + (segment (start 144.145 90.805) (end 144.78 91.44) (width 0.4) (layer "B.Cu") (net 12) (tstamp befdfbe5-f3e5-423b-a34e-7bba3f218536)) + (segment (start 158.4265 88.265) (end 158.929511 88.768011) (width 0.4) (layer "B.Cu") (net 12) (tstamp cf9dccf4-621e-46ba-9a53-bb6462dfa1fa)) + (segment (start 169.164 89.535) (end 169.164 87.687685) (width 0.4) (layer "B.Cu") (net 12) (tstamp db851147-6a1e-4d19-898c-0ba71182359b)) + (segment (start 166.9719 90.17) (end 168.529 90.17) (width 0.4) (layer "B.Cu") (net 12) (tstamp de370984-7922-4327-a0ba-7cd613995df4)) + (segment (start 169.799 67.690998) (end 169.799 85.471) (width 0.4) (layer "B.Cu") (net 12) (tstamp df3dc9a2-ba40-4c3a-87fe-61cc8e23d71b)) + (segment (start 168.529 90.17) (end 169.164 89.535) (width 0.4) (layer "B.Cu") (net 12) (tstamp e69c64f9-717d-4a97-b3df-80325ec2fa63)) + (segment (start 163.957 94.996) (end 165.354 93.599) (width 0.4) (layer "B.Cu") (net 12) (tstamp e70d061b-28f0-4421-ad15-0598604086e8)) + (segment (start 170.814998 66.675) (end 170.814998 61.722002) (width 0.4) (layer "B.Cu") (net 12) (tstamp e79c8e11-ed47-4701-ae80-a54cdb6682a5)) + (segment (start 170.814998 66.675) (end 169.799 67.690998) (width 0.4) (layer "B.Cu") (net 12) (tstamp e87a6f80-914f-4f62-9c9f-9ba62a88ee3d)) (segment (start 134.62 64.77) (end 138.938 64.77) (width 0.25) (layer "F.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d996e)) (segment (start 143.002 66.04) (end 144.272 64.77) (width 0.25) (layer "F.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d9971)) (segment (start 138.938 64.77) (end 140.208 66.04) (width 0.25) (layer "F.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d9974)) @@ -2077,28 +2093,29 @@ (segment (start 130.175 67.31) (end 128.905 66.04) (width 0.25) (layer "F.Cu") (net 13) (tstamp 8d063f79-9282-4820-bcf4-1ff3c006cf08)) (segment (start 132.08 69.85) (end 131.445 69.85) (width 0.25) (layer "F.Cu") (net 13) (tstamp 9da1ace0-4181-4f12-80f8-16786a9e5c07)) (segment (start 128.905 66.04) (end 127 66.04) (width 0.25) (layer "F.Cu") (net 13) (tstamp af186015-d283-4209-aade-a247e5de01df)) - (via (at 182.245 87.63) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 355ced6c-c08a-4586-9a09-7a9c624536f6)) (via (at 164.338 86.36) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 3993c707-5291-41b6-83c0-d1c09cb3833a)) - (via (at 176.657 77.47) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 631c7be5-8dc2-4df4-ab73-737bb928e763)) (via (at 156.845 52.705) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 6d2a06fb-0b1e-452a-ab38-11a5f45e1b32)) (via (at 164.338 60.96) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 78b44915-d68e-4488-a873-34767153ef98)) (via (at 155.575 60.96) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp 92848721-49b5-4e4c-b042-6fd51e1d562f)) (via (at 155.9052 86.36) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp c401e9c6-1deb-4979-99be-7c801c952098)) + (via (at 163.703 79.502) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 13) (tstamp d2447a6a-d2af-4246-88c9-a675126b977f)) (segment (start 142.24 74.93) (end 143.51 76.2) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d995c)) (segment (start 143.51 76.2) (end 143.51 78.74) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d995f)) (segment (start 143.51 78.74) (end 144.78 80.01) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d9962)) (segment (start 144.78 64.77) (end 143.51 66.04) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d9965)) (segment (start 143.51 66.04) (end 143.51 68.58) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d9968)) - (segment (start 143.51 68.58) (end 142.24 69.85) (width 0.25) (layer "B.Cu") (net 13) (tstamp 00000000-0000-0000-0000-0000609d996b)) (segment (start 134.62 80.01) (end 133.35 78.74) (width 0.25) (layer "B.Cu") (net 13) (tstamp 0554bea0-89b2-4e25-9ea3-4c73921c94cb)) + (segment (start 143.51 68.58) (end 143.4465 68.6435) (width 0.25) (layer "B.Cu") (net 13) (tstamp 0cd7aeba-e3f6-4089-97dc-fd05f0b311bb)) (segment (start 157.545 60.325) (end 162.495 60.325) (width 0.25) (layer "B.Cu") (net 13) (tstamp 18f1018d-5857-4c32-a072-f3de80352f74)) (segment (start 130.175 78.74) (end 129.94 78.505) (width 0.25) (layer "B.Cu") (net 13) (tstamp 22962957-1efd-404d-83db-5b233b6c15b0)) (segment (start 129.54 62.23) (end 127.345 62.23) (width 0.25) (layer "B.Cu") (net 13) (tstamp 275b6416-db29-42cc-9307-bf426917c3b4)) (segment (start 157.545 86.995) (end 156.5402 86.995) (width 0.25) (layer "B.Cu") (net 13) (tstamp 29cbb0bc-f66b-4d11-80e7-5bb270e42496)) + (segment (start 143.51 68.58) (end 146.304 68.58) (width 0.25) (layer "B.Cu") (net 13) (tstamp 33787b27-d3b1-4dd6-95b2-f3e31be4ca65)) (segment (start 127.345 62.23) (end 127 61.885) (width 0.25) (layer "B.Cu") (net 13) (tstamp 3c22d605-7855-4cc6-8ad2-906cadbd02dc)) (segment (start 157.545 85.725) (end 156.5402 85.725) (width 0.25) (layer "B.Cu") (net 13) (tstamp 3ed2c840-383d-4cbd-bc3b-c4ea4c97b333)) (segment (start 130.175 58.42) (end 130.175 57.15) (width 0.25) (layer "B.Cu") (net 13) (tstamp 4086cbd7-6ba7-4e63-8da9-17e60627ee17)) (segment (start 134.62 59.69) (end 133.35 58.42) (width 0.25) (layer "B.Cu") (net 13) (tstamp 465137b4-f6f7-4d51-9b40-b161947d5cc1)) + (segment (start 143.4465 68.6435) (end 142.24 69.85) (width 0.25) (layer "B.Cu") (net 13) (tstamp 68cae994-3531-47a6-b112-88796fd20971)) (segment (start 156.5402 86.995) (end 155.9052 86.36) (width 0.25) (layer "B.Cu") (net 13) (tstamp 6a0919c2-460c-4229-b872-14e318e1ba8b)) (segment (start 133.35 78.74) (end 130.175 78.74) (width 0.25) (layer "B.Cu") (net 13) (tstamp 88606262-3ac5-44a1-aacc-18b26cf4d396)) (segment (start 134.62 64.77) (end 133.35 63.5) (width 0.25) (layer "B.Cu") (net 13) (tstamp 8eb98c56-17e4-4de6-a3e3-06dcfa392040)) @@ -2112,7 +2129,6 @@ (segment (start 156.5402 85.725) (end 155.9052 86.36) (width 0.25) (layer "B.Cu") (net 13) (tstamp d1c19c11-0a13-4237-b6b4-fb2ef1db7c6d)) (segment (start 133.35 58.42) (end 130.175 58.42) (width 0.25) (layer "B.Cu") (net 13) (tstamp d1cd5391-31d2-459f-8adb-4ae3f304a833)) (segment (start 174.197 88.58) (end 174.197 93.745) (width 0.25) (layer "B.Cu") (net 13) (tstamp d8200a86-aa75-47a3-ad2a-7f4c9c999a6f)) - (segment (start 157.418 61.468) (end 157.545 61.595) (width 0.25) (layer "B.Cu") (net 13) (tstamp db1ed10a-ef86-43bf-93dc-9be76327f6d2)) (segment (start 134.62 77.47) (end 136.144 77.47) (width 0.25) (layer "F.Cu") (net 14) (tstamp 00000000-0000-0000-0000-0000609d99f5)) (segment (start 136.144 77.47) (end 137.414 78.74) (width 0.25) (layer "F.Cu") (net 14) (tstamp 00000000-0000-0000-0000-0000609d99f8)) (segment (start 137.414 78.74) (end 143.51 78.74) (width 0.25) (layer "F.Cu") (net 14) (tstamp 00000000-0000-0000-0000-0000609d99fb)) @@ -2230,13 +2246,14 @@ (segment (start 152.4 81.28) (end 154.051 81.28) (width 0.25) (layer "B.Cu") (net 20) (tstamp d45d1afe-78e6-4045-862c-b274469da903)) (segment (start 127 53.575) (end 127.816666 53.575) (width 0.25) (layer "B.Cu") (net 20) (tstamp d68dca9b-48b3-498b-9b5f-3b3838250f82)) (segment (start 150.114 78.994) (end 152.4 81.28) (width 0.25) (layer "B.Cu") (net 20) (tstamp f203116d-f256-4611-a03e-9536bbedaf2f)) - (segment (start 132.08 85.09) (end 133.35 86.36) (width 0.25) (layer "F.Cu") (net 21) (tstamp 00000000-0000-0000-0000-0000609d9b2a)) - (segment (start 133.35 86.36) (end 140.97 86.36) (width 0.25) (layer "F.Cu") (net 21) (tstamp 00000000-0000-0000-0000-0000609d9b2d)) - (segment (start 140.97 86.36) (end 142.24 85.09) (width 0.25) (layer "F.Cu") (net 21) (tstamp 00000000-0000-0000-0000-0000609d9b30)) (segment (start 141.29301 52.13901) (end 139.954 50.8) (width 0.25) (layer "F.Cu") (net 21) (tstamp 082aed28-f9e8-49e7-96ee-b5aa9f0319c7)) + (segment (start 136.525 85.09) (end 142.24 85.09) (width 0.25) (layer "F.Cu") (net 21) (tstamp 31beeea0-c8cc-4aa1-88da-7c4048f7c17b)) + (segment (start 132.08 85.09) (end 133.35 83.82) (width 0.25) (layer "F.Cu") (net 21) (tstamp 47eddd87-860a-45bc-b840-3b4b9d222530)) (segment (start 152.4 58.42) (end 146.11901 52.13901) (width 0.25) (layer "F.Cu") (net 21) (tstamp 645bdbdc-8f65-42ef-a021-2d3e7d74a739)) (segment (start 130.175 85.09) (end 132.08 85.09) (width 0.25) (layer "F.Cu") (net 21) (tstamp 8b963561-586b-4575-b721-87e7914602c6)) + (segment (start 135.255 83.82) (end 136.525 85.09) (width 0.25) (layer "F.Cu") (net 21) (tstamp 96d65130-4be9-4a42-bb75-39c2ef4ef6d7)) (segment (start 127 82.66) (end 127.745 82.66) (width 0.25) (layer "F.Cu") (net 21) (tstamp b8c8c7a1-d546-4878-9de9-463ec76dff98)) + (segment (start 133.35 83.82) (end 135.255 83.82) (width 0.25) (layer "F.Cu") (net 21) (tstamp bc4b2316-5063-4666-a0bd-5219985076f2)) (segment (start 127.745 82.66) (end 130.175 85.09) (width 0.25) (layer "F.Cu") (net 21) (tstamp da862bae-4511-4bb9-b18d-fa60a2737feb)) (segment (start 146.11901 52.13901) (end 141.29301 52.13901) (width 0.25) (layer "F.Cu") (net 21) (tstamp fe6d9604-2924-4f38-950b-a31e8a281973)) (via (at 139.954 50.8) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 21) (tstamp bf6104a1-a529-4c00-b4ae-92001543f7ec)) @@ -2397,11 +2414,11 @@ (segment (start 133.35 55.88) (end 139.95259 55.88) (width 0.25) (layer "F.Cu") (net 30) (tstamp 00000000-0000-0000-0000-0000609d9a61)) (segment (start 139.95259 55.88) (end 141.22259 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp 00000000-0000-0000-0000-0000609d9a64)) (segment (start 141.22259 57.15) (end 142.24 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp 00000000-0000-0000-0000-0000609d9a67)) - (segment (start 127.882 52.19) (end 130.302 54.61) (width 0.25) (layer "F.Cu") (net 30) (tstamp 0e592cd4-1950-44ef-9727-8e526f4c4e12)) - (segment (start 131.191 57.15) (end 132.08 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp 2295a793-dfca-4b86-a3e5-abf1834e2790)) - (segment (start 127 52.19) (end 127.882 52.19) (width 0.25) (layer "F.Cu") (net 30) (tstamp 5bbde4f9-fcdb-4d27-a2d6-3847fcdd87ba)) - (segment (start 130.302 54.61) (end 130.302 56.261) (width 0.25) (layer "F.Cu") (net 30) (tstamp a150f0c9-1a23-4200-b489-18791f6d5ce5)) - (segment (start 130.302 56.261) (end 131.191 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp e77c17df-b20e-4e7d-b937-f281c75a0014)) + (segment (start 129.921 54.229) (end 129.921 55.88) (width 0.25) (layer "F.Cu") (net 30) (tstamp 4311839b-820a-4feb-88c5-5d47474b42de)) + (segment (start 127.882 52.19) (end 129.921 54.229) (width 0.25) (layer "F.Cu") (net 30) (tstamp 480e985c-9971-4652-bd2a-3848d072b3a5)) + (segment (start 127 52.19) (end 127.882 52.19) (width 0.25) (layer "F.Cu") (net 30) (tstamp c1de7d4a-0534-400d-b386-236192d4bc3d)) + (segment (start 129.921 55.88) (end 131.191 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp cdf6fe86-837f-4ed6-8714-6a824aa8d64a)) + (segment (start 131.191 57.15) (end 132.08 57.15) (width 0.25) (layer "F.Cu") (net 30) (tstamp d3fa4411-a446-4e4e-bb1f-a790c25a9d85)) (segment (start 161.432001 84.455) (end 162.495 84.455) (width 0.25) (layer "B.Cu") (net 30) (tstamp 07652224-af43-42a2-841c-1883ba305bc4)) (segment (start 152.4 76.2) (end 153.924 76.2) (width 0.25) (layer "B.Cu") (net 30) (tstamp 39845449-7a31-4262-86b1-e7af14a6659f)) (segment (start 140.843 55.753) (end 140.843 53.721998) (width 0.25) (layer "B.Cu") (net 30) (tstamp 46491a9d-8b3d-4c74-b09a-70c876f162e5)) @@ -2414,15 +2431,15 @@ (segment (start 141.351998 53.213) (end 146.05 53.213) (width 0.25) (layer "B.Cu") (net 30) (tstamp cdfb661b-489b-4b76-99f4-62b92bb1ab18)) (segment (start 153.924 76.2) (end 159.004 81.28) (width 0.25) (layer "B.Cu") (net 30) (tstamp dd6c35f3-ae45-4706-ad6f-8028797ca8e0)) (segment (start 142.24 57.15) (end 140.843 55.753) (width 0.25) (layer "B.Cu") (net 30) (tstamp e80b0e91-f15f-4e36-9a9c-b2cfd5a01d2a)) - (segment (start 131.953 54.61) (end 132.08 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 21573090-1953-4b11-9042-108ae79fe9c5)) - (segment (start 127 49.42) (end 127.906 49.42) (width 0.25) (layer "F.Cu") (net 31) (tstamp 2cd3975a-2259-4fa9-8133-e1586b9b9618)) - (segment (start 131.191 53.848) (end 131.953 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 53719fc4-141e-4c58-98cd-ab3bf9a4e1c0)) + (segment (start 129.286 51.943) (end 131.953 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 26c80a0e-68e9-4abd-9483-9fe9f2b20021)) + (segment (start 129.286 50.8) (end 129.286 51.943) (width 0.25) (layer "F.Cu") (net 31) (tstamp 6c4ef2ff-50a5-478b-8b00-f132daad6fba)) (segment (start 133.35 53.34) (end 139.827 53.34) (width 0.25) (layer "F.Cu") (net 31) (tstamp 8615dae0-65cf-4932-8e6f-9a0f32429a5e)) + (segment (start 131.953 54.61) (end 132.08 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 87918f54-f5af-46f8-8d26-8086f5af937d)) (segment (start 141.097 54.61) (end 142.24 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 91c82043-0b26-427f-b23c-6094224ddfc2)) (segment (start 139.827 53.34) (end 141.097 54.61) (width 0.25) (layer "F.Cu") (net 31) (tstamp 97e5f992-979e-4291-bd9a-a77c3fd4b1b5)) + (segment (start 127.906 49.42) (end 129.286 50.8) (width 0.25) (layer "F.Cu") (net 31) (tstamp b446b9e4-24c0-4dda-95bb-010aa2564eb5)) (segment (start 132.08 54.61) (end 133.35 53.34) (width 0.25) (layer "F.Cu") (net 31) (tstamp b547dd70-2ea7-4cfd-a1ee-911561975d81)) - (segment (start 127.906 49.42) (end 131.191 52.705) (width 0.25) (layer "F.Cu") (net 31) (tstamp c5565d96-c729-4597-a74f-7f75befcc39d)) - (segment (start 131.191 52.705) (end 131.191 53.848) (width 0.25) (layer "F.Cu") (net 31) (tstamp fe4869dc-e96e-4bb4-a38d-2ca990635f2d)) + (segment (start 127 49.42) (end 127.906 49.42) (width 0.25) (layer "F.Cu") (net 31) (tstamp bd5ef232-c318-4156-8db0-7aa59d92482e)) (segment (start 160.02 88.646) (end 160.909 89.535) (width 0.25) (layer "B.Cu") (net 31) (tstamp 09c6ca89-863f-42d4-867e-9a769c316610)) (segment (start 143.51 57.809) (end 144.121 58.42) (width 0.25) (layer "B.Cu") (net 31) (tstamp 0a8dfc5c-35dc-4e44-a2bf-5968ebf90cca)) (segment (start 159.258 85.09) (end 160.02 85.852) (width 0.25) (layer "B.Cu") (net 31) (tstamp 28b01cd2-da3a-46ec-8825-b0f31a0b8987)) @@ -2437,68 +2454,65 @@ (segment (start 142.24 54.61) (end 143.51 55.88) (width 0.25) (layer "B.Cu") (net 31) (tstamp c2a9d834-7cb1-4ec5-b0ba-ae56215ff9fc)) (segment (start 143.51 55.88) (end 143.51 57.809) (width 0.25) (layer "B.Cu") (net 31) (tstamp c9badf80-21f8-404a-b5df-18e98bffebf9)) (segment (start 144.121 58.42) (end 145.522501 58.42) (width 0.25) (layer "B.Cu") (net 31) (tstamp fb1a635e-b207-4b36-b0fb-e877e480e86a)) - (segment (start 173.482 79.502) (end 167.64 73.66) (width 0.25) (layer "F.Cu") (net 32) (tstamp 70abf340-8b3e-403e-a5e2-d8f35caa2f87)) - (segment (start 179.578 79.502) (end 173.482 79.502) (width 0.25) (layer "F.Cu") (net 32) (tstamp 7de6564c-7ad6-4d57-a54c-8d2835ff5cdc)) - (segment (start 180.846 78.234) (end 179.578 79.502) (width 0.25) (layer "F.Cu") (net 32) (tstamp dff67d5c-d976-4516-ae67-dbbdb70f8ddd)) - (segment (start 181.965 78.234) (end 180.846 78.234) (width 0.25) (layer "F.Cu") (net 32) (tstamp f6dcb5b4-0971-448a-b9ab-6db37a750704)) - (segment (start 168.382501 72.39) (end 171.557501 75.565) (width 0.25) (layer "F.Cu") (net 33) (tstamp 004b7456-c25a-480f-88f6-723c1bcd9939)) - (segment (start 179.705 75.565) (end 180.34 76.2) (width 0.25) (layer "F.Cu") (net 33) (tstamp 3b6dda98-f455-4961-854e-3c4cceecffcc)) - (segment (start 171.557501 75.565) (end 179.705 75.565) (width 0.25) (layer "F.Cu") (net 33) (tstamp 42f10020-b50a-4739-a546-6b63e441c980)) - (segment (start 181.799 76.2) (end 181.965 76.034) (width 0.25) (layer "F.Cu") (net 33) (tstamp 68039801-1b0f-480a-861d-d55f24af0c17)) - (segment (start 167.64 76.2) (end 166.37 74.93) (width 0.25) (layer "F.Cu") (net 33) (tstamp 832b5a8c-7fe2-47ff-beee-cebf840750bb)) - (segment (start 180.34 76.2) (end 181.799 76.2) (width 0.25) (layer "F.Cu") (net 33) (tstamp af6ac8e6-193c-4bd2-ac0b-7f515b538a8b)) - (segment (start 167.024499 72.39) (end 168.382501 72.39) (width 0.25) (layer "F.Cu") (net 33) (tstamp b55dabdc-b790-4740-9349-75159cff975a)) - (segment (start 166.37 73.044499) (end 167.024499 72.39) (width 0.25) (layer "F.Cu") (net 33) (tstamp b8b15b51-8345-4a1d-8ecf-04fc15b9e450)) - (segment (start 166.37 74.93) (end 166.37 73.044499) (width 0.25) (layer "F.Cu") (net 33) (tstamp eafb53d1-7486-4935-b154-2efbffbed6ca)) - (segment (start 172.357999 75.075999) (end 170.561 73.279) (width 0.31) (layer "F.Cu") (net 34) (tstamp 003974b6-cb8f-491b-a226-fc7891eb9a62)) - (segment (start 173.228 85.725) (end 171.45 83.947) (width 0.31) (layer "F.Cu") (net 34) (tstamp 122b5574-57fe-4d2d-80bf-3cabd28e7128)) - (segment (start 129.667 91.44) (end 138.684 91.44) (width 0.31) (layer "F.Cu") (net 34) (tstamp 2522909e-6f5c-4f36-9c3a-869dca14e50f)) - (segment (start 138.684 91.44) (end 140.189001 92.945001) (width 0.31) (layer "F.Cu") (net 34) (tstamp 3a45fb3b-7899-44f2-a78a-f676359df67b)) - (segment (start 181.823001 75.075999) (end 172.357999 75.075999) (width 0.31) (layer "F.Cu") (net 34) (tstamp 7c0866b5-b180-4be6-9e62-43f5b191d6d4)) - (segment (start 140.189001 92.945001) (end 140.589 93.345) (width 0.31) (layer "F.Cu") (net 34) (tstamp a647641f-bf16-4177-91ee-b01f347ff91c)) - (segment (start 167.64 55.88) (end 170.434 58.674) (width 0.31) (layer "F.Cu") (net 34) (tstamp b66731e7-61d5-4447-bf6a-e91a62b82298)) - (segment (start 170.434 58.674) (end 171.577 58.674) (width 0.31) (layer "F.Cu") (net 34) (tstamp c56bbebe-0c9a-418d-911e-b8ba7c53125d)) - (segment (start 181.965 74.934) (end 181.823001 75.075999) (width 0.31) (layer "F.Cu") (net 34) (tstamp d1817a81-d444-4cd9-95f6-174ec9e2a60e)) - (segment (start 176.927 85.725) (end 173.228 85.725) (width 0.31) (layer "F.Cu") (net 34) (tstamp e42fd0d4-9927-4308-81d9-4cca814c8ea9)) - (segment (start 129.54 91.313) (end 129.667 91.44) (width 0.31) (layer "F.Cu") (net 34) (tstamp fd4dd248-3e78-4985-a4fc-58bc05b74cbf)) + (segment (start 181.965 78.234) (end 181.61 78.234) (width 0.25) (layer "F.Cu") (net 32) (tstamp 3a7f8f44-da2c-4e28-8b7d-dbe1ac29772c)) + (segment (start 169.588489 75.608489) (end 167.64 73.66) (width 0.25) (layer "F.Cu") (net 32) (tstamp 6f5c2ba4-aa6b-4da8-b3fd-afa1270d0494)) + (segment (start 178.984489 75.608489) (end 169.588489 75.608489) (width 0.25) (layer "F.Cu") (net 32) (tstamp 719828ad-f4d8-4517-b466-be42fa0d5fc0)) + (segment (start 181.61 78.234) (end 178.984489 75.608489) (width 0.25) (layer "F.Cu") (net 32) (tstamp 7ee8f9b8-7d65-4dc4-ab5d-80f7cc15d0a4)) + (segment (start 167.64 76.2) (end 166.37 74.93) (width 0.25) (layer "F.Cu") (net 33) (tstamp 2be552ea-ee50-45e5-be34-c822be66120e)) + (segment (start 180.682 76.034) (end 181.965 76.034) (width 0.25) (layer "F.Cu") (net 33) (tstamp 34179aa5-464c-44f7-8673-b728aebc1c60)) + (segment (start 170.970012 74.977511) (end 179.625511 74.977511) (width 0.25) (layer "F.Cu") (net 33) (tstamp 489f3c2a-4d39-4322-8208-1a722c0e887c)) + (segment (start 168.382501 72.39) (end 170.970012 74.977511) (width 0.25) (layer "F.Cu") (net 33) (tstamp 641b8655-b709-4091-8b2f-b9ad0fec6a24)) + (segment (start 166.37 74.93) (end 166.37 73.044499) (width 0.25) (layer "F.Cu") (net 33) (tstamp 6658dfb6-b2ff-4bd0-ac0d-fd2f889b54f7)) + (segment (start 167.024499 72.39) (end 168.382501 72.39) (width 0.25) (layer "F.Cu") (net 33) (tstamp ed4532d3-d99b-4b63-a891-893564d3bffa)) + (segment (start 166.37 73.044499) (end 167.024499 72.39) (width 0.25) (layer "F.Cu") (net 33) (tstamp f8206da3-4c3b-4593-8bc9-4f1d1c9bd04b)) + (segment (start 179.625511 74.977511) (end 180.682 76.034) (width 0.25) (layer "F.Cu") (net 33) (tstamp ffa38048-eeb8-4def-afe8-e12a50536eaf)) + (segment (start 180.594 74.676) (end 180.852 74.934) (width 0.3) (layer "F.Cu") (net 34) (tstamp 0fe63c74-3508-4e76-914d-a9ad0778f2d1)) + (segment (start 173.228 85.725) (end 171.45 83.947) (width 0.3) (layer "F.Cu") (net 34) (tstamp 122b5574-57fe-4d2d-80bf-3cabd28e7128)) + (segment (start 128.016 91.44) (end 138.684 91.44) (width 0.3) (layer "F.Cu") (net 34) (tstamp 4e3de216-806e-4512-9a8b-02e04c3cb85f)) + (segment (start 180.852 74.934) (end 181.965 74.934) (width 0.3) (layer "F.Cu") (net 34) (tstamp 562ca6eb-b571-40e7-b27f-86fbf3e5efb5)) + (segment (start 138.684 91.44) (end 140.589 93.345) (width 0.3) (layer "F.Cu") (net 34) (tstamp 5aef3c88-4f00-47b8-a1ec-98f4416c77fa)) + (segment (start 127.889 91.313) (end 128.016 91.44) (width 0.3) (layer "F.Cu") (net 34) (tstamp a27f7690-1df0-4eed-a7d7-a0520d77a60c)) + (segment (start 167.64 55.88) (end 170.434 58.674) (width 0.3) (layer "F.Cu") (net 34) (tstamp b66731e7-61d5-4447-bf6a-e91a62b82298)) + (segment (start 170.434 58.674) (end 171.577 58.674) (width 0.3) (layer "F.Cu") (net 34) (tstamp c56bbebe-0c9a-418d-911e-b8ba7c53125d)) + (segment (start 176.927 85.725) (end 173.228 85.725) (width 0.3) (layer "F.Cu") (net 34) (tstamp e42fd0d4-9927-4308-81d9-4cca814c8ea9)) (via (at 171.45 83.947) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 34) (tstamp 4f4bd227-fa4c-47f4-ad05-ee16ad4c58c2)) - (via (at 170.561 73.279) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 34) (tstamp 6316acb7-63a1-40e7-8695-2822d4a240b5)) + (via (at 180.594 74.676) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 34) (tstamp 6316acb7-63a1-40e7-8695-2822d4a240b5)) (via (at 171.577 58.674) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 34) (tstamp 6e9883d7-9642-4425-a248-b92a09f0624c)) (via (at 140.589 93.345) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 34) (tstamp c81031ca-cd56-4ea3-b0db-833cbbdd7b2e)) - (segment (start 169.926 91.059) (end 168.275 92.71) (width 0.31) (layer "B.Cu") (net 34) (tstamp 2d617fad-47fe-4db9-836a-4bceb9c31c3b)) - (segment (start 168.275 92.71) (end 167.005 92.71) (width 0.31) (layer "B.Cu") (net 34) (tstamp 2e36ce87-4661-4b8f-956a-16dc559e1b50)) - (segment (start 153.249999 98.210001) (end 152.4 99.06) (width 0.31) (layer "B.Cu") (net 34) (tstamp 4688ff87-8262-46f4-ad96-b5f4e529cfa9)) - (segment (start 163.957 95.758) (end 155.702 95.758) (width 0.31) (layer "B.Cu") (net 34) (tstamp 4d3a1f72-d521-46ae-8fe1-3f8221038335)) - (segment (start 170.942 87.249) (end 169.926 88.265) (width 0.31) (layer "B.Cu") (net 34) (tstamp 5b70b09b-6762-4725-9d48-805300c0bdc8)) - (segment (start 170.561 68.326) (end 170.561 73.279) (width 0.31) (layer "B.Cu") (net 34) (tstamp 653e74f0-0a40-4ab5-8f5c-787bbaf1d723)) - (segment (start 169.926 88.265) (end 169.926 91.059) (width 0.31) (layer "B.Cu") (net 34) (tstamp 6ce41a48-c5e2-4d5f-8548-1c7b5c309a8a)) - (segment (start 151.384 100.076) (end 144.018 100.076) (width 0.31) (layer "B.Cu") (net 34) (tstamp 81b95d0d-8967-4ed1-8d40-39925d015ae8)) - (segment (start 144.018 100.076) (end 140.589 96.647) (width 0.31) (layer "B.Cu") (net 34) (tstamp 83a363ef-2850-4113-853b-2966af02d72d)) - (segment (start 167.005 92.71) (end 163.957 95.758) (width 0.31) (layer "B.Cu") (net 34) (tstamp 843b53af-dd34-4db8-aa6b-5035b25affc7)) - (segment (start 170.561 83.058) (end 170.561 73.279) (width 0.31) (layer "B.Cu") (net 34) (tstamp 8765371a-21c2-4fe3-a3af-88f5eb1f02a0)) - (segment (start 171.577 58.674) (end 171.577 67.31) (width 0.31) (layer "B.Cu") (net 34) (tstamp 8ef1307e-4e79-474d-a93c-be38f714571c)) - (segment (start 155.702 95.758) (end 153.249999 98.210001) (width 0.31) (layer "B.Cu") (net 34) (tstamp 92bd1111-b941-4c03-b7ec-a08a9359bc50)) - (segment (start 152.4 99.06) (end 151.384 100.076) (width 0.31) (layer "B.Cu") (net 34) (tstamp b24c67bf-acb7-486e-9d7b-fb513b8c7fc6)) - (segment (start 171.45 83.947) (end 170.561 83.058) (width 0.31) (layer "B.Cu") (net 34) (tstamp da337fe1-c322-4637-ad26-2622b82ac8ee)) - (segment (start 140.589 96.647) (end 140.589 93.345) (width 0.31) (layer "B.Cu") (net 34) (tstamp e07c4b69-e0b4-4217-9b28-38d44f166b31)) - (segment (start 171.577 67.31) (end 170.561 68.326) (width 0.31) (layer "B.Cu") (net 34) (tstamp ec2e3d8a-128c-4be8-b432-9738bca934ae)) - (segment (start 171.45 87.249) (end 171.45 83.947) (width 0.31) (layer "B.Cu") (net 34) (tstamp ed952427-2217-4500-9bbc-0c2746b198ad)) - (segment (start 181.918 73.787) (end 181.965 73.834) (width 0.25) (layer "F.Cu") (net 35) (tstamp 08da8f18-02c3-4a28-a400-670f01755980)) - (segment (start 173.863 71.374) (end 178.308 71.374) (width 0.25) (layer "F.Cu") (net 35) (tstamp 444b2eaf-241d-42e5-8717-27a83d099c5b)) - (segment (start 173.609 71.12) (end 173.863 71.374) (width 0.25) (layer "F.Cu") (net 35) (tstamp 469f89fd-f629-46b7-b106-a0088168c9ec)) - (segment (start 180.721 73.787) (end 181.918 73.787) (width 0.25) (layer "F.Cu") (net 35) (tstamp 7255cbd1-8d38-4545-be9a-7fc5488ef942)) - (segment (start 178.308 71.374) (end 180.721 73.787) (width 0.25) (layer "F.Cu") (net 35) (tstamp 971d1932-4a99-4265-9c76-26e554bde4fe)) - (segment (start 167.64 71.12) (end 173.609 71.12) (width 0.25) (layer "F.Cu") (net 35) (tstamp d8dc9b6c-67d0-4a0d-a791-6f7d43ef3652)) - (segment (start 167.64 78.74) (end 165.608 76.708) (width 0.25) (layer "F.Cu") (net 36) (tstamp 0938c137-668b-4d2f-b92b-cadb1df72bdb)) - (segment (start 179.832 70.739) (end 181.827 72.734) (width 0.25) (layer "F.Cu") (net 36) (tstamp 1b98de85-f9de-4825-baf2-c96991615275)) - (segment (start 166.770499 69.85) (end 168.656 69.85) (width 0.25) (layer "F.Cu") (net 36) (tstamp 37728c8e-efcc-462c-a749-47b6bfcbaf37)) - (segment (start 168.656 69.85) (end 169.164 70.358) (width 0.25) (layer "F.Cu") (net 36) (tstamp 5698a460-6e24-4857-84d8-4a43acd2325d)) - (segment (start 173.736 70.358) (end 174.117 70.739) (width 0.25) (layer "F.Cu") (net 36) (tstamp 8220ba36-5fda-4461-95e2-49a5bc0c76af)) - (segment (start 174.117 70.739) (end 179.832 70.739) (width 0.25) (layer "F.Cu") (net 36) (tstamp 848c6095-3966-404d-9f2a-51150fd8dc54)) - (segment (start 169.164 70.358) (end 173.736 70.358) (width 0.25) (layer "F.Cu") (net 36) (tstamp d4e4ffa8-e3e2-4590-b9df-630d1880f3e4)) - (segment (start 165.608 76.708) (end 165.608 71.012499) (width 0.25) (layer "F.Cu") (net 36) (tstamp dde4c43d-f33e-48ba-86f3-779fdfce00c2)) - (segment (start 181.827 72.734) (end 181.965 72.734) (width 0.25) (layer "F.Cu") (net 36) (tstamp fbb5e77c-4b41-4796-ad13-1b9e2bbc3c81)) - (segment (start 165.608 71.012499) (end 166.770499 69.85) (width 0.25) (layer "F.Cu") (net 36) (tstamp fdc57161-f7f8-4584-b0ec-8c1aa24339c6)) + (segment (start 164.296481 95.545519) (end 157.519881 95.545519) (width 0.3) (layer "B.Cu") (net 34) (tstamp 36f39ee9-e698-4643-b915-01ad7b03b4cc)) + (segment (start 168.275 92.71) (end 167.132 92.71) (width 0.3) (layer "B.Cu") (net 34) (tstamp 41e69137-9c8a-492d-82b8-5d8ab7d8e1b7)) + (segment (start 156.825882 94.85152) (end 156.60848 94.85152) (width 0.3) (layer "B.Cu") (net 34) (tstamp 4c41b824-e3e3-4ded-82b8-dc614afac99f)) + (segment (start 156.60848 94.85152) (end 152.4 99.06) (width 0.3) (layer "B.Cu") (net 34) (tstamp 4c5361dc-502b-4642-9ee1-9380a04cad68)) + (segment (start 169.926 91.059) (end 168.275 92.71) (width 0.3) (layer "B.Cu") (net 34) (tstamp 4c5492f2-1bf4-4351-821c-91942cd29639)) + (segment (start 170.561 68.326) (end 170.561 73.279) (width 0.3) (layer "B.Cu") (net 34) (tstamp 653e74f0-0a40-4ab5-8f5c-787bbaf1d723)) + (segment (start 157.519881 95.545519) (end 156.825882 94.85152) (width 0.3) (layer "B.Cu") (net 34) (tstamp 69cbc504-efeb-4eea-8582-ed5dc0bbc380)) + (segment (start 151.384 100.076) (end 144.018 100.076) (width 0.3) (layer "B.Cu") (net 34) (tstamp 81b95d0d-8967-4ed1-8d40-39925d015ae8)) + (segment (start 144.018 100.076) (end 140.589 96.647) (width 0.3) (layer "B.Cu") (net 34) (tstamp 83a363ef-2850-4113-853b-2966af02d72d)) + (segment (start 170.561 83.058) (end 170.561 73.279) (width 0.3) (layer "B.Cu") (net 34) (tstamp 8765371a-21c2-4fe3-a3af-88f5eb1f02a0)) + (segment (start 171.577 58.674) (end 171.577 67.31) (width 0.3) (layer "B.Cu") (net 34) (tstamp 8ef1307e-4e79-474d-a93c-be38f714571c)) + (segment (start 169.926 88.265) (end 169.926 91.059) (width 0.3) (layer "B.Cu") (net 34) (tstamp 9e249505-8ac5-4bd4-ad79-2a189e3dbc87)) + (segment (start 152.4 99.06) (end 151.384 100.076) (width 0.3) (layer "B.Cu") (net 34) (tstamp b24c67bf-acb7-486e-9d7b-fb513b8c7fc6)) + (segment (start 171.45 83.947) (end 170.561 83.058) (width 0.3) (layer "B.Cu") (net 34) (tstamp da337fe1-c322-4637-ad26-2622b82ac8ee)) + (segment (start 171.958 74.676) (end 170.561 73.279) (width 0.3) (layer "B.Cu") (net 34) (tstamp df84158a-0102-408a-acc1-a79da875ef7f)) + (segment (start 140.589 96.647) (end 140.589 93.345) (width 0.3) (layer "B.Cu") (net 34) (tstamp e07c4b69-e0b4-4217-9b28-38d44f166b31)) + (segment (start 167.132 92.71) (end 164.296481 95.545519) (width 0.3) (layer "B.Cu") (net 34) (tstamp e7a55f93-bd84-4e33-84d8-a62c7a9afbb7)) + (segment (start 171.577 67.31) (end 170.561 68.326) (width 0.3) (layer "B.Cu") (net 34) (tstamp ec2e3d8a-128c-4be8-b432-9738bca934ae)) + (segment (start 171.45 87.249) (end 171.45 83.947) (width 0.3) (layer "B.Cu") (net 34) (tstamp ed952427-2217-4500-9bbc-0c2746b198ad)) + (segment (start 180.594 74.676) (end 171.958 74.676) (width 0.3) (layer "B.Cu") (net 34) (tstamp f0c929b6-31b9-4564-ae81-1056319855cd)) + (segment (start 170.942 87.249) (end 169.926 88.265) (width 0.3) (layer "B.Cu") (net 34) (tstamp febfe941-c28f-494e-9815-36944754e524)) + (segment (start 175.133 71.374) (end 177.546 73.787) (width 0.25) (layer "F.Cu") (net 35) (tstamp 10d5fd08-1dd7-44a1-8f66-ddf73d9b7179)) + (segment (start 167.894 71.374) (end 175.133 71.374) (width 0.25) (layer "F.Cu") (net 35) (tstamp 83391784-e8fe-44df-9c4e-a8ce39bedeab)) + (segment (start 167.64 71.12) (end 167.894 71.374) (width 0.25) (layer "F.Cu") (net 35) (tstamp bda1cc07-8131-4ad2-808f-92e82c34b064)) + (segment (start 177.546 73.787) (end 181.918 73.787) (width 0.25) (layer "F.Cu") (net 35) (tstamp eb95adf4-e28c-4d18-a15c-3f452917683d)) + (segment (start 181.918 73.787) (end 181.965 73.834) (width 0.25) (layer "F.Cu") (net 35) (tstamp fd0125d9-8bfd-4422-9a98-6674e54d26a0)) + (segment (start 167.64 78.74) (end 165.608 76.708) (width 0.25) (layer "F.Cu") (net 36) (tstamp 2adb0a18-468a-4dbc-8273-36bced110674)) + (segment (start 169.545 70.739) (end 175.26 70.739) (width 0.25) (layer "F.Cu") (net 36) (tstamp 4dbbad71-1d51-4f64-be02-b1a8c2c82684)) + (segment (start 175.26 70.739) (end 177.255 72.734) (width 0.25) (layer "F.Cu") (net 36) (tstamp 63ae5875-81cc-44ae-985b-ffd31c2f34c2)) + (segment (start 165.608 76.708) (end 165.608 71.012499) (width 0.25) (layer "F.Cu") (net 36) (tstamp 76a5e638-bc54-4e43-9485-6bcabd7c77b4)) + (segment (start 177.255 72.734) (end 181.965 72.734) (width 0.25) (layer "F.Cu") (net 36) (tstamp 7bb590f4-0143-4b82-a3ed-5336c7abc66d)) + (segment (start 165.608 71.012499) (end 166.770499 69.85) (width 0.25) (layer "F.Cu") (net 36) (tstamp 7f8cd5fd-8e0c-456d-acca-2f420f92feae)) + (segment (start 166.770499 69.85) (end 168.656 69.85) (width 0.25) (layer "F.Cu") (net 36) (tstamp 8412e092-8b6a-46f1-af82-0c8b759fc0db)) + (segment (start 168.656 69.85) (end 169.545 70.739) (width 0.25) (layer "F.Cu") (net 36) (tstamp ef43f2e1-2a9b-431f-aa11-6f159b2c59c9)) (segment (start 178.927 89.408) (end 183.871 89.408) (width 0.25) (layer "F.Cu") (net 39) (tstamp 74096bdc-b668-408c-af3a-b048c20bd605)) (segment (start 160.782 53.768) (end 161.21 53.34) (width 0.25) (layer "B.Cu") (net 40) (tstamp 00000000-0000-0000-0000-00006062441f)) (segment (start 157.545 59.055) (end 158.23 59.055) (width 0.25) (layer "B.Cu") (net 40) (tstamp 89df70f4-3579-42b9-861e-6beb04a3b25e)) @@ -2531,28 +2545,29 @@ (segment (start 164.592 67.31) (end 168.91 67.31) (width 0.25) (layer "B.Cu") (net 42) (tstamp b21625e3-a75b-41d7-9f13-4c0e12ba16cb)) (segment (start 163.957 63.642) (end 163.957 66.675) (width 0.25) (layer "B.Cu") (net 42) (tstamp db902262-2864-4997-aeff-8abaa132424a)) (segment (start 165.227 87.63) (end 164.592 88.265) (width 0.25) (layer "B.Cu") (net 42) (tstamp fec6f717-d723-4676-89ef-8ea691e209c2)) - (segment (start 146.685 87.63) (end 152.898251 87.63) (width 0.25) (layer "F.Cu") (net 43) (tstamp 05e45f00-3c6b-4c0c-9ffb-3fe26fcda007)) - (segment (start 129.54 88.773) (end 129.667 88.9) (width 0.25) (layer "F.Cu") (net 43) (tstamp 2fb9964c-4cd4-4e81-b5e8-f78759d3adb5)) - (segment (start 160.518251 80.01) (end 169.037 80.01) (width 0.25) (layer "F.Cu") (net 43) (tstamp 40b38567-9d6a-4691-bccf-1b4dbe39957b)) - (segment (start 184.531 83.811) (end 172.856 83.811) (width 0.25) (layer "F.Cu") (net 43) (tstamp 6aa022fb-09ce-49d9-86b1-c73b3ee817e2)) - (segment (start 145.415 88.9) (end 146.685 87.63) (width 0.25) (layer "F.Cu") (net 43) (tstamp 6f44a349-1ba9-4965-b217-aa1589a07228)) - (segment (start 172.856 83.811) (end 172.847 83.82) (width 0.25) (layer "F.Cu") (net 43) (tstamp 7e498af5-a41b-4f8f-8a13-10c00a9160aa)) - (segment (start 152.898251 87.63) (end 160.518251 80.01) (width 0.25) (layer "F.Cu") (net 43) (tstamp 8385d9f6-6997-423b-b38d-d0ab00c45f3f)) - (segment (start 129.667 88.9) (end 145.415 88.9) (width 0.25) (layer "F.Cu") (net 43) (tstamp b45059f3-613f-4b7a-a70a-ed75a9e941e6)) - (segment (start 169.037 80.01) (end 172.847 83.82) (width 0.25) (layer "F.Cu") (net 43) (tstamp e3c3d042-f4c5-4fb1-a6b8-52aa1c14cc0e)) + (segment (start 157.978251 82.55) (end 152.898251 87.63) (width 0.25) (layer "F.Cu") (net 43) (tstamp 1517b3a3-16f3-4041-8201-9697db27bed3)) + (segment (start 152.898251 87.63) (end 146.685 87.63) (width 0.25) (layer "F.Cu") (net 43) (tstamp 1ca14608-acb1-4426-ac41-6f0ddf5c9cbc)) + (segment (start 172.847 83.82) (end 171.577 82.55) (width 0.25) (layer "F.Cu") (net 43) (tstamp 50b26744-05ce-41a6-a1e1-c11de81f55dc)) + (segment (start 128.016 88.9) (end 127.889 88.773) (width 0.25) (layer "F.Cu") (net 43) (tstamp 5d26e6a0-1141-4e71-8d36-d65c6649e92d)) + (segment (start 146.685 87.63) (end 145.415 88.9) (width 0.25) (layer "F.Cu") (net 43) (tstamp 71d50955-76e6-4cea-ac65-4d182c5ae379)) + (segment (start 171.577 82.55) (end 157.978251 82.55) (width 0.25) (layer "F.Cu") (net 43) (tstamp 81fc94e0-ab08-4455-89f8-346361fbc1ce)) + (segment (start 183.76 84.582) (end 173.609 84.582) (width 0.25) (layer "F.Cu") (net 43) (tstamp 9baddefb-e899-4bcb-893d-105337bfffe7)) + (segment (start 145.415 88.9) (end 128.016 88.9) (width 0.25) (layer "F.Cu") (net 43) (tstamp bcdadb00-97df-40d2-ae10-f9b6873ab4de)) + (segment (start 173.609 84.582) (end 172.847 83.82) (width 0.25) (layer "F.Cu") (net 43) (tstamp d67e5ef9-158e-4916-ad8c-5930e76025fc)) + (segment (start 184.531 83.811) (end 183.76 84.582) (width 0.25) (layer "F.Cu") (net 43) (tstamp f95ed1fe-688d-471e-9d12-5bfdd57cd901)) (via (at 172.847 83.82) (size 0.8) (drill 0.4) (layers "F.Cu" "B.Cu") (net 43) (tstamp df93f76b-86da-45ae-87e2-4b691af12b00)) (segment (start 172.847 84.385685) (end 172.847 83.82) (width 0.25) (layer "B.Cu") (net 43) (tstamp 2151a218-87ec-4d43-b5fa-736242c52602)) (segment (start 172.067 88.534) (end 172.847 87.754) (width 0.25) (layer "B.Cu") (net 43) (tstamp 4c8704fa-310a-4c01-8dc1-2b7e2727fea0)) (segment (start 171.517 88.534) (end 172.067 88.534) (width 0.25) (layer "B.Cu") (net 43) (tstamp 6742a066-6a5f-4185-90ae-b7fe8c6eda52)) (segment (start 172.847 87.754) (end 172.847 84.385685) (width 0.25) (layer "B.Cu") (net 43) (tstamp a6dc1180-19c4-432b-af49-fc9179bb4519)) - (segment (start 137.18 97.155) (end 129.54 97.155) (width 0.31) (layer "F.Cu") (net 46) (tstamp 04d60995-4f82-4f17-8f82-2f27a0a779cc)) - (segment (start 129.54 94.615) (end 130.175 95.25) (width 0.31) (layer "B.Cu") (net 47) (tstamp 1a813eeb-ee58-4579-81e1-3f9a7227213c)) - (segment (start 130.175 95.25) (end 133.477 95.25) (width 0.31) (layer "B.Cu") (net 47) (tstamp 621c8eb9-ae87-439a-b350-badb5d559a5a)) - (segment (start 134.62 91.948) (end 134.9375 91.6305) (width 0.31) (layer "B.Cu") (net 47) (tstamp 72cc7949-68f8-4ef8-adcb-a65c1d042672)) - (segment (start 134.62 95.377) (end 134.62 91.948) (width 0.31) (layer "B.Cu") (net 47) (tstamp b2001159-b6cb-4000-85f5-34f6c410920f)) - (segment (start 134.9375 91.6305) (end 135.509 91.059) (width 0.31) (layer "B.Cu") (net 47) (tstamp f74eb612-4697-4cb4-afe4-9f94828b954d)) - (segment (start 134.112 95.885) (end 134.62 95.377) (width 0.31) (layer "B.Cu") (net 47) (tstamp fab1abc4-c49d-4b88-8c7f-939d7feb7b6c)) - (segment (start 133.477 95.25) (end 134.112 95.885) (width 0.31) (layer "B.Cu") (net 47) (tstamp fb191df4-267d-4797-80dd-be346b8eeb99)) + (segment (start 138.05 97.155) (end 129.54 97.155) (width 0.35) (layer "F.Cu") (net 46) (tstamp d4fccaf9-1d55-4626-b431-c5782e41da79)) + (segment (start 129.54 94.615) (end 130.175 95.25) (width 0.35) (layer "B.Cu") (net 47) (tstamp 1a813eeb-ee58-4579-81e1-3f9a7227213c)) + (segment (start 130.175 95.25) (end 133.477 95.25) (width 0.35) (layer "B.Cu") (net 47) (tstamp 621c8eb9-ae87-439a-b350-badb5d559a5a)) + (segment (start 134.62 91.948) (end 134.9375 91.6305) (width 0.35) (layer "B.Cu") (net 47) (tstamp 72cc7949-68f8-4ef8-adcb-a65c1d042672)) + (segment (start 134.62 95.377) (end 134.62 91.948) (width 0.35) (layer "B.Cu") (net 47) (tstamp b2001159-b6cb-4000-85f5-34f6c410920f)) + (segment (start 134.9375 91.6305) (end 135.509 91.059) (width 0.35) (layer "B.Cu") (net 47) (tstamp f74eb612-4697-4cb4-afe4-9f94828b954d)) + (segment (start 134.112 95.885) (end 134.62 95.377) (width 0.35) (layer "B.Cu") (net 47) (tstamp fab1abc4-c49d-4b88-8c7f-939d7feb7b6c)) + (segment (start 133.477 95.25) (end 134.112 95.885) (width 0.35) (layer "B.Cu") (net 47) (tstamp fb191df4-267d-4797-80dd-be346b8eeb99)) (segment (start 175.776201 62.797001) (end 177.774998 62.797001) (width 0.25) (layer "F.Cu") (net 48) (tstamp 01109662-12b4-48a3-b68d-624008909c2a)) (segment (start 181.226999 59.345) (end 182.72 59.345) (width 0.25) (layer "F.Cu") (net 48) (tstamp 0e166909-afb5-4d70-a00b-dd78cd09b084)) (segment (start 175.133 61.722) (end 175.2854 61.8744) (width 0.25) (layer "F.Cu") (net 48) (tstamp 1b5a32e4-0b8e-4f38-b679-71dc277c2087)) @@ -2571,15 +2586,16 @@ (segment (start 169.037 93.091) (end 169.037 95.123) (width 0.25) (layer "B.Cu") (net 50) (tstamp bc1d5740-b0c7-4566-95b0-470ac47a1fb3)) (segment (start 173.101 88.138) (end 173.101 89.027) (width 0.25) (layer "B.Cu") (net 50) (tstamp d8370835-89ad-4b62-9f40-d0c10470788a)) (segment (start 173.101 89.027) (end 169.037 93.091) (width 0.25) (layer "B.Cu") (net 50) (tstamp eb1b2aa2-a3cc-4a96-87ec-70fcae365f0f)) - (segment (start 130.175 100.33) (end 139.466 100.33) (width 0.31) (layer "F.Cu") (net 51) (tstamp 6b69fc79-c78f-4df1-9a05-c51d4173705f)) - (segment (start 129.54 99.695) (end 130.175 100.33) (width 0.31) (layer "F.Cu") (net 51) (tstamp f2392fe0-54af-4e02-8793-9ba2471944b5)) - (segment (start 134.62 82.55) (end 135.89 83.82) (width 0.31) (layer "F.Cu") (net 52) (tstamp 00000000-0000-0000-0000-0000609d99b9)) - (segment (start 135.89 83.82) (end 143.51 83.82) (width 0.31) (layer "F.Cu") (net 52) (tstamp 00000000-0000-0000-0000-0000609d99bc)) - (segment (start 143.51 83.82) (end 144.78 82.55) (width 0.31) (layer "F.Cu") (net 52) (tstamp 00000000-0000-0000-0000-0000609d99bf)) - (segment (start 133.345 81.275) (end 134.62 82.55) (width 0.31) (layer "B.Cu") (net 52) (tstamp 0fc912fd-5036-4a55-b598-a9af40810824)) - (segment (start 143.51 83.82) (end 143.51 88.135) (width 0.31) (layer "B.Cu") (net 52) (tstamp 2a6ee718-8cdf-4fa6-be7c-8fe885d98fd7)) - (segment (start 144.78 82.55) (end 143.51 83.82) (width 0.31) (layer "B.Cu") (net 52) (tstamp 55cff608-ab38-48d9-ac09-2d0a877ceca1)) - (segment (start 127 81.275) (end 133.345 81.275) (width 0.31) (layer "B.Cu") (net 52) (tstamp e0b36e60-bb2b-489c-a764-1b81e551ce62)) + (segment (start 129.54 99.695) (end 130.175 100.33) (width 0.35) (layer "F.Cu") (net 51) (tstamp 54d92c42-b841-4026-b4bd-1a76c4565b13)) + (segment (start 130.175 100.33) (end 139.066 100.33) (width 0.35) (layer "F.Cu") (net 51) (tstamp c7fa0557-42d7-400e-95f3-0d459b9bf38c)) + (segment (start 135.509 82.55) (end 136.779 83.82) (width 0.4) (layer "F.Cu") (net 52) (tstamp 0eadf0ed-f35f-4e31-99dc-9d7eb8546609)) + (segment (start 136.779 83.82) (end 143.51 83.82) (width 0.4) (layer "F.Cu") (net 52) (tstamp 5bde45f6-df3d-4f54-a13c-0373944eecbf)) + (segment (start 143.51 83.82) (end 144.78 82.55) (width 0.4) (layer "F.Cu") (net 52) (tstamp 66a0834e-c325-4cdd-96ef-11ae3dc8a596)) + (segment (start 134.62 82.55) (end 135.509 82.55) (width 0.4) (layer "F.Cu") (net 52) (tstamp ad2f3948-5820-4c91-a745-6303f46c18a6)) + (segment (start 133.345 81.275) (end 134.62 82.55) (width 0.4) (layer "B.Cu") (net 52) (tstamp 0fc912fd-5036-4a55-b598-a9af40810824)) + (segment (start 143.51 83.82) (end 143.51 88.135) (width 0.4) (layer "B.Cu") (net 52) (tstamp 2a6ee718-8cdf-4fa6-be7c-8fe885d98fd7)) + (segment (start 144.78 82.55) (end 143.51 83.82) (width 0.4) (layer "B.Cu") (net 52) (tstamp 55cff608-ab38-48d9-ac09-2d0a877ceca1)) + (segment (start 127 81.275) (end 133.345 81.275) (width 0.4) (layer "B.Cu") (net 52) (tstamp e0b36e60-bb2b-489c-a764-1b81e551ce62)) (segment (start 184.531 85.861) (end 179.063 85.861) (width 0.25) (layer "F.Cu") (net 53) (tstamp 680c3e83-f590-4924-85a1-36d51b076683)) (segment (start 179.063 85.861) (end 178.927 85.725) (width 0.25) (layer "F.Cu") (net 53) (tstamp e07e1653-d05d-4bf2-bea3-6515a06de065)) @@ -2598,25 +2614,25 @@ (filled_polygon (layer "F.Cu") (pts - (xy 171.543641 47.518502) - (xy 171.564615 47.535405) - (xy 172.448188 48.418978) - (xy 172.462132 48.426592) - (xy 172.463965 48.426461) - (xy 172.47058 48.42221) - (xy 173.357385 47.535405) - (xy 173.419697 47.501379) - (xy 173.44648 47.4985) - (xy 176.55552 47.4985) - (xy 176.623641 47.518502) - (xy 176.644615 47.535405) - (xy 177.528188 48.418978) - (xy 177.542132 48.426592) - (xy 177.543965 48.426461) - (xy 177.55058 48.42221) - (xy 178.437385 47.535405) - (xy 178.499697 47.501379) - (xy 178.52648 47.4985) + (xy 171.593641 47.518502) + (xy 171.614615 47.535405) + (xy 172.498188 48.418978) + (xy 172.512132 48.426592) + (xy 172.513965 48.426461) + (xy 172.52058 48.42221) + (xy 173.407385 47.535405) + (xy 173.469697 47.501379) + (xy 173.49648 47.4985) + (xy 176.60552 47.4985) + (xy 176.673641 47.518502) + (xy 176.694615 47.535405) + (xy 177.578188 48.418978) + (xy 177.592132 48.426592) + (xy 177.593965 48.426461) + (xy 177.60058 48.42221) + (xy 178.487385 47.535405) + (xy 178.549697 47.501379) + (xy 178.57648 47.4985) (xy 179.401633 47.4985) (xy 179.421018 47.5) (xy 179.435852 47.50231) @@ -2821,10 +2837,10 @@ (xy 181.488659 93.285183) (xy 181.484444 93.286755) (xy 181.484441 93.286756) - (xy 181.310681 93.351565) + (xy 181.321545 93.347513) (xy 181.250297 93.374087) (xy 181.246347 93.376244) - (xy 181.048421 93.48432) + (xy 181.121084 93.444643) (xy 181.027014 93.496009) (xy 181.023411 93.498706) (xy 181.023405 93.49871) @@ -2841,7 +2857,7 @@ (xy 180.280183 94.493659) (xy 180.279228 94.49805) (xy 180.279226 94.498056) - (xy 180.243236 94.663502) + (xy 180.258221 94.594616) (xy 180.226106 94.742247) (xy 180.225785 94.746735) (xy 180.209711 94.971477) @@ -2862,7 +2878,7 @@ (xy 180.208473 101.094626) (xy 180.20875 101.096746) (xy 180.209207 101.125431) - (xy 180.201997 101.198642) + (xy 180.204985 101.168297) (xy 180.199084 101.228212) (xy 180.194267 101.252432) (xy 180.158134 101.371546) @@ -2887,26 +2903,26 @@ (xy 179.435856 101.85111) (xy 179.425714 101.852436) (xy 179.409379 101.8535) - (xy 178.52648 101.8535) - (xy 178.458359 101.833498) - (xy 178.437385 101.816595) - (xy 177.553812 100.933022) - (xy 177.539868 100.925408) - (xy 177.538035 100.925539) - (xy 177.53142 100.92979) - (xy 176.644615 101.816595) - (xy 176.582303 101.850621) - (xy 176.55552 101.8535) - (xy 173.44648 101.8535) - (xy 173.378359 101.833498) - (xy 173.357385 101.816595) - (xy 172.473812 100.933022) - (xy 172.459868 100.925408) - (xy 172.458035 100.925539) - (xy 172.45142 100.92979) - (xy 171.564615 101.816595) - (xy 171.502303 101.850621) - (xy 171.47552 101.8535) + (xy 178.57648 101.8535) + (xy 178.508359 101.833498) + (xy 178.487385 101.816595) + (xy 177.603812 100.933022) + (xy 177.589868 100.925408) + (xy 177.588035 100.925539) + (xy 177.58142 100.92979) + (xy 176.694615 101.816595) + (xy 176.632303 101.850621) + (xy 176.60552 101.8535) + (xy 173.49648 101.8535) + (xy 173.428359 101.833498) + (xy 173.407385 101.816595) + (xy 172.523812 100.933022) + (xy 172.509868 100.925408) + (xy 172.508035 100.925539) + (xy 172.50142 100.92979) + (xy 171.614615 101.816595) + (xy 171.552303 101.850621) + (xy 171.52552 101.8535) (xy 126.414367 101.8535) (xy 126.394982 101.852) (xy 126.380148 101.84969) @@ -2946,7 +2962,7 @@ (xy 128.141042 100.263101) (xy 128.143429 100.267687) (xy 128.143431 100.267691) - (xy 128.249584 100.471607) + (xy 128.225665 100.42566) (xy 128.251975 100.4762) (xy 128.255085 100.480342) (xy 128.322838 100.57058) @@ -2972,56 +2988,49 @@ (xy 130.054932 101.084053) (xy 130.054933 101.084053) (xy 130.059944 101.082794) - (xy 130.185856 101.028046) - (xy 130.241274 101.00395) - (xy 130.291516 100.9935) - (xy 138.396865 100.9935) - (xy 138.464986 101.013502) - (xy 138.506378 101.061272) - (xy 138.507923 101.060426) - (xy 138.512235 101.068302) - (xy 138.515385 101.076705) - (xy 138.520765 101.083884) - (xy 138.520767 101.083887) - (xy 138.574813 101.156) - (xy 138.602739 101.193261) - (xy 138.719295 101.280615) - (xy 138.855684 101.331745) - (xy 138.917866 101.3385) - (xy 140.014134 101.3385) - (xy 140.076316 101.331745) - (xy 140.212705 101.280615) - (xy 140.329261 101.193261) - (xy 140.416615 101.076705) - (xy 140.467745 100.940316) - (xy 140.4745 100.878134) - (xy 140.4745 99.781866) - (xy 140.467745 99.719684) - (xy 140.416615 99.583295) - (xy 140.329261 99.466739) - (xy 140.212705 99.379385) - (xy 140.076316 99.328255) - (xy 140.014134 99.3215) - (xy 138.917866 99.3215) - (xy 138.855684 99.328255) - (xy 138.719295 99.379385) - (xy 138.602739 99.466739) - (xy 138.597358 99.473919) - (xy 138.520767 99.576113) - (xy 138.520765 99.576116) - (xy 138.515385 99.583295) - (xy 138.512235 99.591698) - (xy 138.507923 99.599574) - (xy 138.504932 99.597937) - (xy 138.47218 99.641513) - (xy 138.405612 99.666196) - (xy 138.396865 99.6665) - (xy 135.095067 99.6665) - (xy 135.026946 99.646498) - (xy 134.980453 99.592842) - (xy 134.970349 99.522568) - (xy 134.999843 99.457988) - (xy 135.006127 99.45125) + (xy 130.160376 101.039125) + (xy 130.195277 101.02395) + (xy 130.245519 101.0135) + (xy 138.016874 101.0135) + (xy 138.084995 101.033502) + (xy 138.131488 101.087158) + (xy 138.134856 101.09527) + (xy 138.149765 101.13504) + (xy 138.165385 101.176705) + (xy 138.252739 101.293261) + (xy 138.369295 101.380615) + (xy 138.505684 101.431745) + (xy 138.567866 101.4385) + (xy 139.564134 101.4385) + (xy 139.626316 101.431745) + (xy 139.762705 101.380615) + (xy 139.879261 101.293261) + (xy 139.966615 101.176705) + (xy 140.017745 101.040316) + (xy 140.0245 100.978134) + (xy 140.0245 99.681866) + (xy 140.017745 99.619684) + (xy 139.966615 99.483295) + (xy 139.879261 99.366739) + (xy 139.762705 99.279385) + (xy 139.626316 99.228255) + (xy 139.564134 99.2215) + (xy 138.567866 99.2215) + (xy 138.505684 99.228255) + (xy 138.369295 99.279385) + (xy 138.252739 99.366739) + (xy 138.165385 99.483295) + (xy 138.162233 99.491703) + (xy 138.134856 99.56473) + (xy 138.092214 99.621494) + (xy 138.025652 99.646194) + (xy 138.016874 99.6465) + (xy 135.115137 99.6465) + (xy 135.047016 99.626498) + (xy 135.000523 99.572842) + (xy 134.990419 99.502568) + (xy 135.019913 99.437988) + (xy 135.026197 99.43125) (xy 135.146051 99.311812) (xy 135.15273 99.303965) (xy 135.277003 99.13102) @@ -3043,31 +3052,31 @@ (xy 133.009694 99.225388) (xy 133.015777 99.233699) (xy 133.155213 99.394667) - (xy 133.16258 99.401883) - (xy 133.212776 99.443556) - (xy 133.252411 99.502459) - (xy 133.253909 99.573439) - (xy 133.216794 99.633962) - (xy 133.15285 99.664811) - (xy 133.132291 99.6665) - (xy 131.169409 99.6665) - (xy 131.101288 99.646498) - (xy 131.054795 99.592842) - (xy 131.044859 99.559559) - (xy 131.043694 99.551948) + (xy 133.16258 99.401882) + (xy 133.188686 99.423556) + (xy 133.228321 99.482458) + (xy 133.229819 99.553439) + (xy 133.192705 99.613962) + (xy 133.12876 99.644811) + (xy 133.108201 99.6465) + (xy 131.166349 99.6465) + (xy 131.098228 99.626498) + (xy 131.051735 99.572842) + (xy 131.041799 99.539559) + (xy 131.020731 99.401882) (xy 131.013596 99.355256) - (xy 130.971149 99.225388) + (xy 130.96603 99.209726) (xy 130.940566 99.131817) (xy 130.940563 99.131811) (xy 130.938958 99.126899) (xy 130.93163 99.112821) (xy 130.830416 98.918393) (xy 130.828025 98.9138) - (xy 130.766865 98.832342) + (xy 130.763701 98.828128) (xy 130.686882 98.725815) (xy 130.68688 98.725812) (xy 130.683777 98.72168) - (xy 130.573141 98.615954) + (xy 130.567464 98.610529) (xy 130.513825 98.55927) (xy 130.513824 98.559269) (xy 130.510088 98.555699) @@ -3079,188 +3088,183 @@ (xy 130.477635 98.319311) (xy 130.481977 98.316502) (xy 130.65967 98.154814) + (xy 130.783378 97.998172) + (xy 130.805366 97.970331) + (xy 130.805368 97.970328) (xy 130.808568 97.966276) - (xy 130.854205 97.883605) - (xy 130.904636 97.833636) - (xy 130.964512 97.8185) - (xy 132.705171 97.8185) - (xy 132.773292 97.838502) - (xy 132.819785 97.892158) - (xy 132.829889 97.962432) - (xy 132.826588 97.978172) + (xy 130.843163 97.903607) + (xy 130.893596 97.853636) + (xy 130.953472 97.8385) + (xy 132.699624 97.8385) + (xy 132.767745 97.858502) + (xy 132.814238 97.912158) + (xy 132.824342 97.982432) + (xy 132.821041 97.998172) (xy 132.776389 98.159183) (xy 132.777912 98.167607) (xy 132.790292 98.171) (xy 135.430344 98.171) (xy 135.443875 98.167027) (xy 135.44518 98.157947) - (xy 135.403214 97.990873) - (xy 135.401249 97.985102) - (xy 135.398233 97.91417) - (xy 135.434045 97.852867) - (xy 135.497314 97.820657) - (xy 135.520528 97.8185) - (xy 136.110865 97.8185) - (xy 136.178986 97.838502) - (xy 136.220378 97.886272) - (xy 136.221923 97.885426) - (xy 136.226235 97.893302) - (xy 136.229385 97.901705) - (xy 136.234765 97.908884) - (xy 136.234767 97.908887) - (xy 136.286694 97.978172) - (xy 136.316739 98.018261) - (xy 136.433295 98.105615) - (xy 136.569684 98.156745) - (xy 136.631866 98.1635) - (xy 137.728134 98.1635) - (xy 137.790316 98.156745) - (xy 137.926705 98.105615) - (xy 138.043261 98.018261) - (xy 138.130615 97.901705) - (xy 138.181745 97.765316) - (xy 138.1885 97.703134) - (xy 138.1885 97.699669) - (xy 138.672001 97.699669) - (xy 138.672371 97.70649) - (xy 138.677895 97.757352) - (xy 138.681521 97.772604) - (xy 138.726676 97.893054) - (xy 138.735214 97.908649) - (xy 138.811715 98.010724) - (xy 138.824276 98.023285) - (xy 138.926351 98.099786) - (xy 138.941946 98.108324) - (xy 139.062394 98.153478) - (xy 139.077649 98.157105) - (xy 139.128514 98.162631) - (xy 139.135328 98.163) - (xy 139.407885 98.163) - (xy 139.423124 98.158525) - (xy 139.424329 98.157135) - (xy 139.426 98.149452) - (xy 139.426 98.144884) - (xy 139.934 98.144884) - (xy 139.938475 98.160123) - (xy 139.939865 98.161328) - (xy 139.947548 98.162999) - (xy 140.224669 98.162999) - (xy 140.23149 98.162629) - (xy 140.282352 98.157105) - (xy 140.297604 98.153479) - (xy 140.418054 98.108324) - (xy 140.433649 98.099786) - (xy 140.535724 98.023285) - (xy 140.548285 98.010724) - (xy 140.624786 97.908649) - (xy 140.633324 97.893054) - (xy 140.678478 97.772606) - (xy 140.682105 97.757351) - (xy 140.687631 97.706486) - (xy 140.688 97.699672) - (xy 140.688 97.427115) - (xy 140.683525 97.411876) - (xy 140.682135 97.410671) - (xy 140.674452 97.409) - (xy 139.952115 97.409) - (xy 139.936876 97.413475) - (xy 139.935671 97.414865) - (xy 139.934 97.422548) - (xy 139.934 98.144884) - (xy 139.426 98.144884) - (xy 139.426 97.427115) - (xy 139.421525 97.411876) - (xy 139.420135 97.410671) - (xy 139.412452 97.409) - (xy 138.690116 97.409) - (xy 138.674877 97.413475) - (xy 138.673672 97.414865) - (xy 138.672001 97.422548) - (xy 138.672001 97.699669) - (xy 138.1885 97.699669) - (xy 138.1885 96.882885) - (xy 138.672 96.882885) - (xy 138.676475 96.898124) - (xy 138.677865 96.899329) - (xy 138.685548 96.901) - (xy 139.407885 96.901) - (xy 139.423124 96.896525) - (xy 139.424329 96.895135) - (xy 139.426 96.887452) - (xy 139.426 96.882885) - (xy 139.934 96.882885) - (xy 139.938475 96.898124) - (xy 139.939865 96.899329) - (xy 139.947548 96.901) - (xy 140.669884 96.901) - (xy 140.685123 96.896525) - (xy 140.686328 96.895135) - (xy 140.687999 96.887452) - (xy 140.687999 96.610331) - (xy 140.687629 96.60351) - (xy 140.682105 96.552648) - (xy 140.678479 96.537396) - (xy 140.633324 96.416946) - (xy 140.624786 96.401351) - (xy 140.548285 96.299276) - (xy 140.535724 96.286715) - (xy 140.433649 96.210214) - (xy 140.418054 96.201676) - (xy 140.297606 96.156522) - (xy 140.282351 96.152895) - (xy 140.231486 96.147369) - (xy 140.224672 96.147) - (xy 139.952115 96.147) - (xy 139.936876 96.151475) - (xy 139.935671 96.152865) - (xy 139.934 96.160548) - (xy 139.934 96.882885) - (xy 139.426 96.882885) - (xy 139.426 96.165116) - (xy 139.421525 96.149877) - (xy 139.420135 96.148672) - (xy 139.412452 96.147001) - (xy 139.135331 96.147001) - (xy 139.12851 96.147371) - (xy 139.077648 96.152895) - (xy 139.062396 96.156521) - (xy 138.941946 96.201676) - (xy 138.926351 96.210214) - (xy 138.824276 96.286715) - (xy 138.811715 96.299276) - (xy 138.735214 96.401351) - (xy 138.726676 96.416946) - (xy 138.681522 96.537394) - (xy 138.677895 96.552649) - (xy 138.672369 96.603514) - (xy 138.672 96.610328) - (xy 138.672 96.882885) - (xy 138.1885 96.882885) - (xy 138.1885 96.606866) - (xy 138.181745 96.544684) - (xy 138.130615 96.408295) - (xy 138.043261 96.291739) - (xy 137.926705 96.204385) - (xy 137.790316 96.153255) - (xy 137.728134 96.1465) - (xy 136.631866 96.1465) - (xy 136.569684 96.153255) - (xy 136.433295 96.204385) - (xy 136.316739 96.291739) - (xy 136.311358 96.298919) - (xy 136.234767 96.401113) - (xy 136.234765 96.401116) - (xy 136.229385 96.408295) - (xy 136.226235 96.416698) - (xy 136.221923 96.424574) - (xy 136.218932 96.422937) - (xy 136.18618 96.466513) - (xy 136.119612 96.491196) - (xy 136.110865 96.4915) - (xy 135.5965 96.4915) - (xy 135.528379 96.471498) - (xy 135.481886 96.417842) - (xy 135.4705 96.3655) + (xy 135.404299 97.995196) + (xy 135.407103 97.924255) + (xy 135.447816 97.866091) + (xy 135.513511 97.839172) + (xy 135.526503 97.8385) + (xy 137.000874 97.8385) + (xy 137.068995 97.858502) + (xy 137.115488 97.912158) + (xy 137.118856 97.92027) + (xy 137.119544 97.922104) + (xy 137.149385 98.001705) + (xy 137.236739 98.118261) + (xy 137.353295 98.205615) + (xy 137.489684 98.256745) + (xy 137.551866 98.2635) + (xy 138.548134 98.2635) + (xy 138.610316 98.256745) + (xy 138.746705 98.205615) + (xy 138.863261 98.118261) + (xy 138.950615 98.001705) + (xy 139.001745 97.865316) + (xy 139.0085 97.803134) + (xy 139.0085 97.799669) + (xy 140.392001 97.799669) + (xy 140.392371 97.80649) + (xy 140.397895 97.857352) + (xy 140.401521 97.872604) + (xy 140.446676 97.993054) + (xy 140.455214 98.008649) + (xy 140.531715 98.110724) + (xy 140.544276 98.123285) + (xy 140.646351 98.199786) + (xy 140.661946 98.208324) + (xy 140.782394 98.253478) + (xy 140.797649 98.257105) + (xy 140.848514 98.262631) + (xy 140.855328 98.263) + (xy 141.077885 98.263) + (xy 141.093124 98.258525) + (xy 141.094329 98.257135) + (xy 141.096 98.249452) + (xy 141.096 98.244884) + (xy 141.604 98.244884) + (xy 141.608475 98.260123) + (xy 141.609865 98.261328) + (xy 141.617548 98.262999) + (xy 141.844669 98.262999) + (xy 141.85149 98.262629) + (xy 141.902352 98.257105) + (xy 141.917604 98.253479) + (xy 142.038054 98.208324) + (xy 142.053649 98.199786) + (xy 142.155724 98.123285) + (xy 142.168285 98.110724) + (xy 142.244786 98.008649) + (xy 142.253324 97.993054) + (xy 142.298478 97.872606) + (xy 142.302105 97.857351) + (xy 142.307631 97.806486) + (xy 142.308 97.799672) + (xy 142.308 97.427115) + (xy 142.303525 97.411876) + (xy 142.302135 97.410671) + (xy 142.294452 97.409) + (xy 141.622115 97.409) + (xy 141.606876 97.413475) + (xy 141.605671 97.414865) + (xy 141.604 97.422548) + (xy 141.604 98.244884) + (xy 141.096 98.244884) + (xy 141.096 97.427115) + (xy 141.091525 97.411876) + (xy 141.090135 97.410671) + (xy 141.082452 97.409) + (xy 140.410116 97.409) + (xy 140.394877 97.413475) + (xy 140.393672 97.414865) + (xy 140.392001 97.422548) + (xy 140.392001 97.799669) + (xy 139.0085 97.799669) + (xy 139.0085 96.882885) + (xy 140.392 96.882885) + (xy 140.396475 96.898124) + (xy 140.397865 96.899329) + (xy 140.405548 96.901) + (xy 141.077885 96.901) + (xy 141.093124 96.896525) + (xy 141.094329 96.895135) + (xy 141.096 96.887452) + (xy 141.096 96.882885) + (xy 141.604 96.882885) + (xy 141.608475 96.898124) + (xy 141.609865 96.899329) + (xy 141.617548 96.901) + (xy 142.289884 96.901) + (xy 142.305123 96.896525) + (xy 142.306328 96.895135) + (xy 142.307999 96.887452) + (xy 142.307999 96.510331) + (xy 142.307629 96.50351) + (xy 142.302105 96.452648) + (xy 142.298479 96.437396) + (xy 142.253324 96.316946) + (xy 142.244786 96.301351) + (xy 142.168285 96.199276) + (xy 142.155724 96.186715) + (xy 142.053649 96.110214) + (xy 142.038054 96.101676) + (xy 141.917606 96.056522) + (xy 141.902351 96.052895) + (xy 141.851486 96.047369) + (xy 141.844672 96.047) + (xy 141.622115 96.047) + (xy 141.606876 96.051475) + (xy 141.605671 96.052865) + (xy 141.604 96.060548) + (xy 141.604 96.882885) + (xy 141.096 96.882885) + (xy 141.096 96.065116) + (xy 141.091525 96.049877) + (xy 141.090135 96.048672) + (xy 141.082452 96.047001) + (xy 140.855331 96.047001) + (xy 140.84851 96.047371) + (xy 140.797648 96.052895) + (xy 140.782396 96.056521) + (xy 140.661946 96.101676) + (xy 140.646351 96.110214) + (xy 140.544276 96.186715) + (xy 140.531715 96.199276) + (xy 140.455214 96.301351) + (xy 140.446676 96.316946) + (xy 140.401522 96.437394) + (xy 140.397895 96.452649) + (xy 140.392369 96.503514) + (xy 140.392 96.510328) + (xy 140.392 96.882885) + (xy 139.0085 96.882885) + (xy 139.0085 96.506866) + (xy 139.001745 96.444684) + (xy 138.950615 96.308295) + (xy 138.863261 96.191739) + (xy 138.746705 96.104385) + (xy 138.610316 96.053255) + (xy 138.548134 96.0465) + (xy 137.551866 96.0465) + (xy 137.489684 96.053255) + (xy 137.353295 96.104385) + (xy 137.236739 96.191739) + (xy 137.149385 96.308295) + (xy 137.146233 96.316703) + (xy 137.118856 96.38973) + (xy 137.076214 96.446494) + (xy 137.009652 96.471194) + (xy 137.000874 96.4715) + (xy 135.5965 96.4715) + (xy 135.528379 96.451498) + (xy 135.481886 96.397842) + (xy 135.4705 96.3455) (xy 135.4705 94.986866) (xy 135.463745 94.924684) (xy 135.412615 94.788295) @@ -3275,14 +3279,15 @@ (xy 132.811385 94.788295) (xy 132.760255 94.924684) (xy 132.7535 94.986866) - (xy 132.7535 96.3655) - (xy 132.733498 96.433621) - (xy 132.679842 96.480114) - (xy 132.6275 96.4915) - (xy 130.965755 96.4915) - (xy 130.897634 96.471498) - (xy 130.853992 96.423681) - (xy 130.830416 96.378393) + (xy 132.7535 96.3455) + (xy 132.733498 96.413621) + (xy 132.679842 96.460114) + (xy 132.6275 96.4715) + (xy 130.955343 96.4715) + (xy 130.887222 96.451498) + (xy 130.84358 96.40368) + (xy 130.830419 96.378397) + (xy 130.830414 96.378389) (xy 130.828025 96.3738) (xy 130.711585 96.218717) (xy 130.68668 96.152235) @@ -3325,7 +3330,7 @@ (xy 128.271432 96.343724) (xy 128.268939 96.34824) (xy 128.268937 96.348243) - (xy 128.164519 96.537396) + (xy 128.172265 96.523365) (xy 128.155326 96.55405) (xy 128.153602 96.558919) (xy 128.1536 96.558923) @@ -3345,13 +3350,13 @@ (xy 128.141042 97.723101) (xy 128.143429 97.727687) (xy 128.143431 97.727691) - (xy 128.225984 97.886272) + (xy 128.233002 97.899754) (xy 128.251975 97.9362) (xy 128.255085 97.940342) - (xy 128.38121 98.108324) + (xy 128.392711 98.123642) (xy 128.396223 98.12832) (xy 128.440885 98.171) - (xy 128.496825 98.224457) + (xy 128.532475 98.258525) (xy 128.569912 98.294301) (xy 128.606903 98.319535) (xy 128.651904 98.374444) @@ -3375,10 +3380,10 @@ (xy 128.07513 99.320515) (xy 128.074223 99.325608) (xy 128.074222 99.325611) - (xy 128.039139 99.522568) + (xy 128.044637 99.491703) (xy 128.032999 99.557037) - (xy 128.032563 99.592737) - (xy 128.030294 99.778469) + (xy 128.03215 99.626498) + (xy 128.030443 99.766277) (xy 128.030064 99.797263) (xy 125.6035 99.797263) (xy 125.6035 84.217833) @@ -3407,12 +3412,13 @@ (xy 129.857228 85.642759) (xy 129.857232 85.642762) (xy 129.890537 85.657174) - (xy 129.901187 85.662391) + (xy 129.901186 85.66239) (xy 129.93994 85.683695) (xy 129.947615 85.685666) (xy 129.947616 85.685666) (xy 129.959562 85.688733) - (xy 129.978267 85.695137) + (xy 129.978266 85.695137) + (xy 129.978269 85.695138) (xy 129.996855 85.703181) (xy 130.004678 85.70442) (xy 130.004688 85.704423) @@ -3429,17 +3435,18 @@ (xy 130.804274 85.7235) (xy 130.872395 85.743502) (xy 130.911707 85.783665) + (xy 130.919436 85.796277) (xy 130.979987 85.895088) (xy 131.12625 86.063938) (xy 131.298126 86.206632) (xy 131.491 86.319338) (xy 131.495825 86.32118) (xy 131.495826 86.321181) - (xy 131.556293 86.344271) + (xy 131.568612 86.348975) (xy 131.699692 86.39903) (xy 131.70476 86.400061) (xy 131.704763 86.400062) - (xy 131.812012 86.421882) + (xy 131.812017 86.421883) (xy 131.918597 86.443567) (xy 131.923772 86.443757) (xy 131.923774 86.443757) @@ -3451,92 +3458,101 @@ (xy 132.358288 86.424025) (xy 132.358289 86.424025) (xy 132.363416 86.423368) - (xy 132.368367 86.421883) - (xy 132.36837 86.421882) - (xy 132.409829 86.409444) - (xy 132.480825 86.409028) - (xy 132.535131 86.441035) - (xy 132.846343 86.752247) - (xy 132.853887 86.760537) - (xy 132.858 86.767018) - (xy 132.863777 86.772443) - (xy 132.907667 86.813658) - (xy 132.910509 86.816413) - (xy 132.93023 86.836134) - (xy 132.933425 86.838612) - (xy 132.942447 86.846318) - (xy 132.974679 86.876586) - (xy 132.985858 86.882732) - (xy 132.992432 86.886346) - (xy 133.008956 86.897199) - (xy 133.024959 86.909613) - (xy 133.065543 86.927176) - (xy 133.076173 86.932383) - (xy 133.11494 86.953695) - (xy 133.122617 86.955666) - (xy 133.122622 86.955668) - (xy 133.134558 86.958732) - (xy 133.153266 86.965137) - (xy 133.171855 86.973181) - (xy 133.179683 86.974421) - (xy 133.17969 86.974423) - (xy 133.215524 86.980099) - (xy 133.227144 86.982505) - (xy 133.258959 86.990673) - (xy 133.26997 86.9935) - (xy 133.290224 86.9935) - (xy 133.309934 86.995051) - (xy 133.329943 86.99822) - (xy 133.337835 86.997474) - (xy 133.35658 86.995702) - (xy 133.373962 86.994059) - (xy 133.385819 86.9935) - (xy 140.891233 86.9935) - (xy 140.902416 86.994027) - (xy 140.909909 86.995702) - (xy 140.917835 86.995453) - (xy 140.917836 86.995453) - (xy 140.977986 86.993562) - (xy 140.981945 86.9935) - (xy 141.009856 86.9935) - (xy 141.013791 86.993003) - (xy 141.013856 86.992995) - (xy 141.025693 86.992062) - (xy 141.057951 86.991048) - (xy 141.06197 86.990922) - (xy 141.069889 86.990673) - (xy 141.089343 86.985021) - (xy 141.1087 86.981013) - (xy 141.12093 86.979468) - (xy 141.120931 86.979468) - (xy 141.128797 86.978474) - (xy 141.136168 86.975555) - (xy 141.13617 86.975555) - (xy 141.169912 86.962196) - (xy 141.181142 86.958351) - (xy 141.215983 86.948229) - (xy 141.215984 86.948229) - (xy 141.223593 86.946018) - (xy 141.230412 86.941985) - (xy 141.230417 86.941983) - (xy 141.241028 86.935707) - (xy 141.258776 86.927012) - (xy 141.277617 86.919552) - (xy 141.297987 86.904753) - (xy 141.313387 86.893564) - (xy 141.323307 86.887048) - (xy 141.354535 86.86858) - (xy 141.354538 86.868578) - (xy 141.361362 86.864542) - (xy 141.375683 86.850221) - (xy 141.390717 86.83738) - (xy 141.392432 86.836134) - (xy 141.407107 86.825472) - (xy 141.435298 86.791395) - (xy 141.443288 86.782616) - (xy 141.784549 86.441355) - (xy 141.846861 86.407329) - (xy 141.898762 86.406979) + (xy 132.368366 86.421883) + (xy 132.572429 86.360661) + (xy 132.572434 86.360659) + (xy 132.577384 86.359174) + (xy 132.777994 86.260896) + (xy 132.95986 86.131173) + (xy 133.118096 85.973489) + (xy 133.248453 85.792077) + (xy 133.249776 85.793028) + (xy 133.296645 85.749857) + (xy 133.36658 85.737625) + (xy 133.432026 85.765144) + (xy 133.459875 85.796994) + (xy 133.519987 85.895088) + (xy 133.66625 86.063938) + (xy 133.838126 86.206632) + (xy 134.031 86.319338) + (xy 134.035825 86.32118) + (xy 134.035826 86.321181) + (xy 134.108612 86.348975) + (xy 134.239692 86.39903) + (xy 134.24476 86.400061) + (xy 134.244763 86.400062) + (xy 134.352017 86.421883) + (xy 134.458597 86.443567) + (xy 134.463772 86.443757) + (xy 134.463774 86.443757) + (xy 134.676673 86.451564) + (xy 134.676677 86.451564) + (xy 134.681837 86.451753) + (xy 134.686957 86.451097) + (xy 134.686959 86.451097) + (xy 134.898288 86.424025) + (xy 134.898289 86.424025) + (xy 134.903416 86.423368) + (xy 134.908366 86.421883) + (xy 135.112429 86.360661) + (xy 135.112434 86.360659) + (xy 135.117384 86.359174) + (xy 135.317994 86.260896) + (xy 135.49986 86.131173) + (xy 135.658096 85.973489) + (xy 135.788453 85.792077) + (xy 135.792611 85.783665) + (xy 135.885139 85.596447) + (xy 135.88514 85.596445) + (xy 135.88743 85.591811) + (xy 135.888097 85.592141) + (xy 135.929232 85.539431) + (xy 135.996237 85.515961) + (xy 136.065295 85.532442) + (xy 136.091796 85.5527) + (xy 136.10523 85.566134) + (xy 136.10842 85.568608) + (xy 136.117447 85.576318) + (xy 136.149679 85.606586) + (xy 136.160858 85.612732) + (xy 136.167432 85.616346) + (xy 136.183956 85.627199) + (xy 136.199959 85.639613) + (xy 136.240539 85.657174) + (xy 136.251173 85.662383) + (xy 136.28994 85.683695) + (xy 136.297617 85.685666) + (xy 136.297622 85.685668) + (xy 136.309558 85.688732) + (xy 136.328266 85.695137) + (xy 136.346855 85.703181) + (xy 136.354683 85.704421) + (xy 136.35469 85.704423) + (xy 136.390524 85.710099) + (xy 136.402144 85.712505) + (xy 136.437289 85.721528) + (xy 136.44497 85.7235) + (xy 136.465224 85.7235) + (xy 136.484934 85.725051) + (xy 136.504943 85.72822) + (xy 136.512835 85.727474) + (xy 136.548961 85.724059) + (xy 136.560819 85.7235) + (xy 140.964274 85.7235) + (xy 141.032395 85.743502) + (xy 141.071707 85.783665) + (xy 141.079436 85.796277) + (xy 141.139987 85.895088) + (xy 141.28625 86.063938) + (xy 141.458126 86.206632) + (xy 141.651 86.319338) + (xy 141.655825 86.32118) + (xy 141.655826 86.321181) + (xy 141.728612 86.348975) + (xy 141.859692 86.39903) + (xy 141.86476 86.400061) + (xy 141.864763 86.400062) + (xy 141.972017 86.421883) (xy 142.078597 86.443567) (xy 142.083772 86.443757) (xy 142.083774 86.443757) @@ -3548,14 +3564,13 @@ (xy 142.518288 86.424025) (xy 142.518289 86.424025) (xy 142.523416 86.423368) - (xy 142.569827 86.409444) + (xy 142.528366 86.421883) (xy 142.732429 86.360661) (xy 142.732434 86.360659) (xy 142.737384 86.359174) (xy 142.937994 86.260896) (xy 143.11986 86.131173) (xy 143.278096 85.973489) - (xy 143.303845 85.937656) (xy 143.408453 85.792077) (xy 143.409776 85.793028) (xy 143.456645 85.749857) @@ -3568,11 +3583,11 @@ (xy 144.191 86.319338) (xy 144.195825 86.32118) (xy 144.195826 86.321181) - (xy 144.256293 86.344271) + (xy 144.268612 86.348975) (xy 144.399692 86.39903) (xy 144.40476 86.400061) (xy 144.404763 86.400062) - (xy 144.512012 86.421882) + (xy 144.512017 86.421883) (xy 144.618597 86.443567) (xy 144.623772 86.443757) (xy 144.623774 86.443757) @@ -3584,20 +3599,21 @@ (xy 145.058288 86.424025) (xy 145.058289 86.424025) (xy 145.063416 86.423368) - (xy 145.109827 86.409444) + (xy 145.068366 86.421883) (xy 145.272429 86.360661) (xy 145.272434 86.360659) (xy 145.277384 86.359174) (xy 145.477994 86.260896) (xy 145.65986 86.131173) (xy 145.818096 85.973489) - (xy 145.843845 85.937656) - (xy 145.945435 85.796277) (xy 145.948453 85.792077) (xy 145.952611 85.783665) (xy 146.045136 85.596453) (xy 146.045137 85.596451) (xy 146.04743 85.591811) + (xy 146.09442 85.437148) + (xy 146.110865 85.383023) + (xy 146.110865 85.383021) (xy 146.11237 85.378069) (xy 146.141529 85.15659) (xy 146.142597 85.112891) @@ -3634,14 +3650,11 @@ (xy 146.04743 83.051811) (xy 146.11237 82.838069) (xy 146.141529 82.61659) - (xy 146.142678 82.569575) - (xy 146.143074 82.553365) - (xy 146.143074 82.553361) (xy 146.143156 82.55) (xy 146.124852 82.327361) (xy 146.070431 82.110702) (xy 145.981354 81.90584) - (xy 145.897911 81.776857) + (xy 145.898347 81.777531) (xy 145.862822 81.722617) (xy 145.86282 81.722614) (xy 145.860014 81.718277) @@ -3713,7 +3726,6 @@ (xy 150.514445 84.62117) (xy 150.527804 84.654912) (xy 150.531649 84.666142) - (xy 150.538155 84.688536) (xy 150.543982 84.708593) (xy 150.548015 84.715412) (xy 150.548017 84.715417) @@ -3742,7 +3754,7 @@ (xy 151.037251 86.326695) (xy 151.037548 86.331848) (xy 151.037548 86.331851) - (xy 151.047641 86.50689) + (xy 151.044424 86.451097) (xy 151.05011 86.549715) (xy 151.051247 86.554761) (xy 151.051248 86.554767) @@ -3800,110 +3812,110 @@ (xy 145.1895 88.229595) (xy 145.127188 88.263621) (xy 145.100405 88.2665) - (xy 130.88382 88.2665) - (xy 130.815699 88.246498) - (xy 130.768271 88.190744) - (xy 130.766577 88.186848) - (xy 130.741354 88.12884) - (xy 130.620014 87.941277) - (xy 130.46967 87.776051) - (xy 130.465619 87.772852) - (xy 130.465615 87.772848) - (xy 130.298414 87.6408) - (xy 130.29841 87.640798) - (xy 130.294359 87.637598) - (xy 130.283851 87.631797) - (xy 130.206936 87.589338) - (xy 130.098789 87.529638) - (xy 130.09392 87.527914) - (xy 130.093916 87.527912) - (xy 129.893087 87.456795) - (xy 129.893083 87.456794) - (xy 129.888212 87.455069) - (xy 129.883119 87.454162) - (xy 129.883116 87.454161) - (xy 129.673373 87.4168) - (xy 129.673367 87.416799) - (xy 129.668284 87.415894) - (xy 129.594452 87.414992) - (xy 129.450081 87.413228) - (xy 129.450079 87.413228) - (xy 129.444911 87.413165) - (xy 129.224091 87.446955) - (xy 129.011756 87.516357) - (xy 128.813607 87.619507) - (xy 128.809474 87.62261) - (xy 128.809471 87.622612) - (xy 128.640323 87.749612) - (xy 128.634965 87.753635) - (xy 128.631393 87.757373) - (xy 128.49218 87.903051) - (xy 128.480629 87.915138) - (xy 128.354743 88.09968) - (xy 128.312473 88.190744) - (xy 128.275544 88.270301) - (xy 128.260688 88.302305) - (xy 128.200989 88.51757) - (xy 128.177251 88.739695) - (xy 128.177548 88.744848) - (xy 128.177548 88.744851) - (xy 128.186494 88.9) - (xy 128.19011 88.962715) - (xy 128.191247 88.967761) - (xy 128.191248 88.967767) - (xy 128.191731 88.969908) - (xy 128.239222 89.180639) - (xy 128.244251 89.193023) - (xy 128.31911 89.37738) - (xy 128.323266 89.387616) - (xy 128.325965 89.39202) - (xy 128.412702 89.533562) - (xy 128.439987 89.578088) - (xy 128.58625 89.746938) - (xy 128.59023 89.750242) - (xy 128.594981 89.754187) - (xy 128.634616 89.81309) - (xy 128.636113 89.884071) - (xy 128.598997 89.944593) - (xy 128.558725 89.969112) - (xy 128.504693 89.989368) - (xy 128.443295 90.012385) - (xy 128.326739 90.099739) - (xy 128.239385 90.216295) - (xy 128.188255 90.352684) - (xy 128.1815 90.414866) - (xy 128.1815 92.211134) - (xy 128.188255 92.273316) - (xy 128.239385 92.409705) - (xy 128.326739 92.526261) - (xy 128.443295 92.613615) - (xy 128.579684 92.664745) - (xy 128.63556 92.670815) - (xy 128.637678 92.671045) - (xy 128.641866 92.6715) - (xy 130.438134 92.6715) - (xy 130.442323 92.671045) - (xy 130.44444 92.670815) - (xy 130.500316 92.664745) - (xy 130.636705 92.613615) - (xy 130.753261 92.526261) - (xy 130.840615 92.409705) - (xy 130.891745 92.273316) - (xy 130.892598 92.265464) - (xy 130.892599 92.26546) - (xy 130.897983 92.215893) - (xy 130.925225 92.15033) - (xy 130.983588 92.109904) - (xy 131.023246 92.1035) - (xy 138.35698 92.1035) - (xy 138.425101 92.123502) - (xy 138.446075 92.140405) - (xy 139.646861 93.341191) - (xy 139.680887 93.403503) - (xy 139.683075 93.417112) - (xy 139.683821 93.424203) - (xy 139.694388 93.524744) + (xy 129.23282 88.2665) + (xy 129.164699 88.246498) + (xy 129.117271 88.190744) + (xy 129.115577 88.186848) + (xy 129.090354 88.12884) + (xy 128.969014 87.941277) + (xy 128.81867 87.776051) + (xy 128.814619 87.772852) + (xy 128.814615 87.772848) + (xy 128.647414 87.6408) + (xy 128.64741 87.640798) + (xy 128.643359 87.637598) + (xy 128.632851 87.631797) + (xy 128.555936 87.589338) + (xy 128.447789 87.529638) + (xy 128.44292 87.527914) + (xy 128.442916 87.527912) + (xy 128.242087 87.456795) + (xy 128.242083 87.456794) + (xy 128.237212 87.455069) + (xy 128.232119 87.454162) + (xy 128.232116 87.454161) + (xy 128.022373 87.4168) + (xy 128.022367 87.416799) + (xy 128.017284 87.415894) + (xy 127.943452 87.414992) + (xy 127.799081 87.413228) + (xy 127.799079 87.413228) + (xy 127.793911 87.413165) + (xy 127.573091 87.446955) + (xy 127.360756 87.516357) + (xy 127.162607 87.619507) + (xy 127.158474 87.62261) + (xy 127.158471 87.622612) + (xy 126.989323 87.749612) + (xy 126.983965 87.753635) + (xy 126.980393 87.757373) + (xy 126.84118 87.903051) + (xy 126.829629 87.915138) + (xy 126.703743 88.09968) + (xy 126.661473 88.190744) + (xy 126.624544 88.270301) + (xy 126.609688 88.302305) + (xy 126.549989 88.51757) + (xy 126.526251 88.739695) + (xy 126.526548 88.744848) + (xy 126.526548 88.744851) + (xy 126.535494 88.9) + (xy 126.53911 88.962715) + (xy 126.540247 88.967761) + (xy 126.540248 88.967767) + (xy 126.540731 88.969908) + (xy 126.588222 89.180639) + (xy 126.593251 89.193023) + (xy 126.66811 89.37738) + (xy 126.672266 89.387616) + (xy 126.674965 89.39202) + (xy 126.761702 89.533562) + (xy 126.788987 89.578088) + (xy 126.93525 89.746938) + (xy 126.93923 89.750242) + (xy 126.943981 89.754187) + (xy 126.983616 89.81309) + (xy 126.985113 89.884071) + (xy 126.947997 89.944593) + (xy 126.907725 89.969112) + (xy 126.811751 90.005091) + (xy 126.792295 90.012385) + (xy 126.675739 90.099739) + (xy 126.588385 90.216295) + (xy 126.537255 90.352684) + (xy 126.5305 90.414866) + (xy 126.5305 92.211134) + (xy 126.537255 92.273316) + (xy 126.588385 92.409705) + (xy 126.675739 92.526261) + (xy 126.792295 92.613615) + (xy 126.928684 92.664745) + (xy 126.98456 92.670815) + (xy 126.986678 92.671045) + (xy 126.990866 92.6715) + (xy 128.787134 92.6715) + (xy 128.791323 92.671045) + (xy 128.79344 92.670815) + (xy 128.849316 92.664745) + (xy 128.985705 92.613615) + (xy 129.102261 92.526261) + (xy 129.189615 92.409705) + (xy 129.240745 92.273316) + (xy 129.2475 92.211134) + (xy 129.249223 92.211321) + (xy 129.270585 92.150791) + (xy 129.326657 92.107244) + (xy 129.372776 92.0985) + (xy 138.35905 92.0985) + (xy 138.427171 92.118502) + (xy 138.448145 92.135405) + (xy 139.64603 93.33329) + (xy 139.680056 93.395602) + (xy 139.682244 93.409211) (xy 139.695458 93.534928) + (xy 139.697498 93.541205) + (xy 139.697498 93.541207) + (xy 139.701065 93.552184) (xy 139.754473 93.716556) (xy 139.757776 93.722278) (xy 139.757777 93.722279) @@ -3935,10 +3947,10 @@ (xy 141.420224 93.722278) (xy 141.423527 93.716556) (xy 141.482542 93.534928) - (xy 141.483613 93.524744) + (xy 141.484711 93.514297) (xy 141.501814 93.351565) (xy 141.502504 93.345) - (xy 141.496217 93.285183) + (xy 141.496382 93.286756) (xy 141.483232 93.161635) (xy 141.483232 93.161633) (xy 141.482542 93.155072) @@ -3961,64 +3973,66 @@ (xy 140.690944 92.437872) (xy 140.690939 92.437872) (xy 140.684487 92.4365) - (xy 140.67102 92.4365) - (xy 140.602899 92.416498) - (xy 140.581925 92.399595) - (xy 139.891196 91.708865) - (xy 139.172509 90.990178) - (xy 139.166655 90.983912) - (xy 139.136225 90.949029) - (xy 139.131229 90.943302) - (xy 139.082443 90.909015) - (xy 139.077159 90.90509) - (xy 139.036211 90.872983) - (xy 139.030236 90.868298) - (xy 139.023317 90.865174) - (xy 139.017371 90.861573) - (xy 139.012214 90.858632) - (xy 139.006056 90.85533) - (xy 138.99984 90.850961) - (xy 138.992764 90.848202) - (xy 138.992762 90.848201) - (xy 138.944304 90.829308) - (xy 138.938223 90.826752) - (xy 138.89079 90.805335) - (xy 138.890789 90.805335) - (xy 138.883871 90.802211) - (xy 138.876405 90.800827) - (xy 138.869786 90.798753) - (xy 138.864037 90.797115) - (xy 138.857296 90.795385) - (xy 138.850218 90.792625) - (xy 138.826557 90.78951) - (xy 138.791112 90.784844) - (xy 138.784595 90.783812) - (xy 138.750669 90.777524) - (xy 138.725967 90.772946) - (xy 138.718387 90.773383) - (xy 138.718386 90.773383) - (xy 138.667953 90.776291) - (xy 138.6607 90.7765) - (xy 131.0245 90.7765) - (xy 130.956379 90.756498) - (xy 130.909886 90.702842) - (xy 130.8985 90.6505) - (xy 130.8985 90.414866) - (xy 130.891745 90.352684) - (xy 130.840615 90.216295) - (xy 130.753261 90.099739) - (xy 130.636705 90.012385) - (xy 130.59577 89.997039) - (xy 130.518203 89.96796) - (xy 130.461439 89.925318) - (xy 130.436739 89.858756) - (xy 130.451947 89.789408) - (xy 130.473493 89.760727) - (xy 130.574435 89.660137) - (xy 130.578096 89.656489) - (xy 130.628766 89.585974) - (xy 130.684761 89.542326) - (xy 130.731089 89.5335) + (xy 140.66395 92.4365) + (xy 140.595829 92.416498) + (xy 140.574855 92.399595) + (xy 139.207655 91.032395) + (xy 139.199665 91.023615) + (xy 139.199663 91.023613) + (xy 139.195416 91.01692) + (xy 139.17309 90.995954) + (xy 139.143743 90.968396) + (xy 139.140901 90.965641) + (xy 139.120333 90.945073) + (xy 139.116826 90.942353) + (xy 139.107804 90.934647) + (xy 139.079913 90.908456) + (xy 139.074133 90.903028) + (xy 139.067181 90.899206) + (xy 139.055342 90.892697) + (xy 139.038818 90.881843) + (xy 139.028132 90.873555) + (xy 139.021868 90.868696) + (xy 139.014596 90.865549) + (xy 139.014594 90.865548) + (xy 138.979465 90.850346) + (xy 138.968805 90.845124) + (xy 138.935284 90.826695) + (xy 138.935282 90.826694) + (xy 138.928337 90.822876) + (xy 138.907559 90.817541) + (xy 138.888869 90.811142) + (xy 138.869176 90.80262) + (xy 138.823552 90.795394) + (xy 138.811929 90.792987) + (xy 138.783928 90.785798) + (xy 138.767188 90.7815) + (xy 138.745741 90.7815) + (xy 138.726031 90.779949) + (xy 138.712677 90.777834) + (xy 138.704848 90.776594) + (xy 138.658859 90.780941) + (xy 138.647004 90.7815) + (xy 129.3735 90.7815) + (xy 129.305379 90.761498) + (xy 129.258886 90.707842) + (xy 129.2475 90.6555) + (xy 129.2475 90.414866) + (xy 129.240745 90.352684) + (xy 129.189615 90.216295) + (xy 129.102261 90.099739) + (xy 128.985705 90.012385) + (xy 128.973132 90.007672) + (xy 128.867203 89.96796) + (xy 128.810439 89.925318) + (xy 128.785739 89.858756) + (xy 128.800947 89.789408) + (xy 128.822493 89.760727) + (xy 128.923435 89.660137) + (xy 128.927096 89.656489) + (xy 128.977766 89.585974) + (xy 129.033761 89.542326) + (xy 129.080089 89.5335) (xy 145.336233 89.5335) (xy 145.347416 89.534027) (xy 145.354909 89.535702) @@ -4088,7 +4102,7 @@ (xy 151.299987 89.705088) (xy 151.44625 89.873938) (xy 151.618126 90.016632) - (xy 151.669648 90.046739) + (xy 151.629003 90.022988) (xy 151.691445 90.059476) (xy 151.740169 90.111114) (xy 151.75324 90.180897) @@ -4106,7 +4120,7 @@ (xy 151.337714 90.586411) (xy 151.317189 90.6165) (xy 151.214743 90.76668) - (xy 151.170931 90.861065) + (xy 151.195367 90.808423) (xy 151.12375 90.962709) (xy 151.120688 90.969305) (xy 151.060989 91.18457) @@ -4120,7 +4134,7 @@ (xy 151.066626 91.703) (xy 151.099222 91.847639) (xy 151.183266 92.054616) - (xy 151.225479 92.123502) + (xy 151.185965 92.05902) (xy 151.281262 92.214531) (xy 151.299987 92.245088) (xy 151.44625 92.413938) @@ -4139,248 +4153,246 @@ (xy 151.4991 92.95753) (xy 151.494965 92.960635) (xy 151.340629 93.122138) - (xy 151.337715 93.12641) - (xy 151.337714 93.126411) - (xy 151.24556 93.261504) - (xy 151.190649 93.306507) - (xy 151.141472 93.3165) - (xy 144.569224 93.3165) - (xy 144.560654 93.316208) - (xy 144.514471 93.313059) - (xy 144.514467 93.313059) - (xy 144.506895 93.312543) - (xy 144.448133 93.322798) - (xy 144.441641 93.323756) - (xy 144.413152 93.327204) - (xy 144.389988 93.330007) - (xy 144.389986 93.330008) - (xy 144.382446 93.33092) - (xy 144.375346 93.333603) - (xy 144.368603 93.335259) - (xy 144.362823 93.336841) - (xy 144.356171 93.338849) - (xy 144.348694 93.340154) - (xy 144.341748 93.343203) - (xy 144.341745 93.343204) - (xy 144.2941 93.364119) - (xy 144.287997 93.366609) - (xy 144.23222 93.387685) - (xy 144.225956 93.39199) - (xy 144.219782 93.395218) - (xy 144.214557 93.398126) - (xy 144.208594 93.401653) - (xy 144.201645 93.404703) - (xy 144.195619 93.409327) - (xy 144.154359 93.440987) - (xy 144.149023 93.444864) - (xy 144.106137 93.474339) - (xy 144.106131 93.474344) - (xy 144.099872 93.478646) - (xy 144.084402 93.496009) - (xy 144.061211 93.522038) - (xy 144.05623 93.527314) - (xy 141.516178 96.067366) - (xy 141.509913 96.073219) - (xy 141.469302 96.108646) - (xy 141.435023 96.157421) - (xy 141.43109 96.162716) - (xy 141.412886 96.185933) - (xy 141.394298 96.209639) - (xy 141.391174 96.216558) - (xy 141.387573 96.222504) - (xy 141.384632 96.227661) - (xy 141.38133 96.233819) - (xy 141.376961 96.240035) - (xy 141.374202 96.247111) - (xy 141.374201 96.247113) - (xy 141.355308 96.295571) - (xy 141.352752 96.301652) - (xy 141.328211 96.356004) - (xy 141.326827 96.36347) - (xy 141.324753 96.370089) - (xy 141.323115 96.375838) - (xy 141.321385 96.382579) - (xy 141.318625 96.389657) - (xy 141.317633 96.397193) - (xy 141.310844 96.448763) - (xy 141.309812 96.45528) - (xy 141.298946 96.513908) - (xy 141.299383 96.521488) - (xy 141.299383 96.521489) - (xy 141.302291 96.571922) - (xy 141.3025 96.579175) - (xy 141.3025 99.260865) - (xy 141.282498 99.328986) - (xy 141.234728 99.370378) - (xy 141.235574 99.371923) - (xy 141.227698 99.376235) - (xy 141.219295 99.379385) - (xy 141.212116 99.384765) - (xy 141.212113 99.384767) - (xy 141.133672 99.443556) - (xy 141.102739 99.466739) - (xy 141.015385 99.583295) - (xy 140.964255 99.719684) - (xy 140.9575 99.781866) - (xy 140.9575 100.878134) - (xy 140.964255 100.940316) - (xy 141.015385 101.076705) - (xy 141.102739 101.193261) - (xy 141.219295 101.280615) - (xy 141.355684 101.331745) - (xy 141.417866 101.3385) - (xy 142.514134 101.3385) - (xy 142.576316 101.331745) - (xy 142.712705 101.280615) - (xy 142.829261 101.193261) - (xy 142.916615 101.076705) - (xy 142.967745 100.940316) - (xy 142.9745 100.878134) - (xy 142.9745 100.56593) - (xy 170.89857 100.56593) - (xy 170.917035 100.800545) - (xy 170.918578 100.810292) - (xy 170.973517 101.039125) - (xy 170.976566 101.04851) - (xy 171.066625 101.265933) - (xy 171.071107 101.274728) - (xy 171.182072 101.455805) - (xy 171.19253 101.465267) - (xy 171.201306 101.461484) - (xy 172.088978 100.573812) - (xy 172.095356 100.562132) - (xy 172.825408 100.562132) - (xy 172.825539 100.563965) - (xy 172.82979 100.57058) - (xy 173.71765 101.45844) - (xy 173.73003 101.4652) - (xy 173.73768 101.459473) - (xy 173.850893 101.274728) - (xy 173.855375 101.265933) - (xy 173.945434 101.04851) - (xy 173.948483 101.039125) - (xy 174.003422 100.810292) - (xy 174.004965 100.800545) - (xy 174.02343 100.56593) - (xy 175.97857 100.56593) - (xy 175.997035 100.800545) - (xy 175.998578 100.810292) - (xy 176.053517 101.039125) - (xy 176.056566 101.04851) - (xy 176.146625 101.265933) - (xy 176.151107 101.274728) - (xy 176.262072 101.455805) - (xy 176.27253 101.465267) - (xy 176.281306 101.461484) - (xy 177.168978 100.573812) - (xy 177.175356 100.562132) - (xy 177.905408 100.562132) - (xy 177.905539 100.563965) - (xy 177.90979 100.57058) - (xy 178.79765 101.45844) - (xy 178.81003 101.4652) - (xy 178.81768 101.459473) - (xy 178.930893 101.274728) - (xy 178.935375 101.265933) - (xy 179.025434 101.04851) - (xy 179.028483 101.039125) - (xy 179.083422 100.810292) - (xy 179.084965 100.800545) - (xy 179.10343 100.56593) - (xy 179.10343 100.55607) - (xy 179.084965 100.321455) - (xy 179.083422 100.311708) - (xy 179.028483 100.082875) - (xy 179.025434 100.07349) - (xy 178.935375 99.856067) - (xy 178.930893 99.847272) - (xy 178.819928 99.666195) - (xy 178.80947 99.656733) - (xy 178.800694 99.660516) - (xy 177.913022 100.548188) - (xy 177.905408 100.562132) - (xy 177.175356 100.562132) - (xy 177.176592 100.559868) - (xy 177.176461 100.558035) - (xy 177.17221 100.55142) - (xy 176.28435 99.66356) - (xy 176.27197 99.6568) - (xy 176.26432 99.662527) - (xy 176.151107 99.847272) - (xy 176.146625 99.856067) - (xy 176.056566 100.07349) - (xy 176.053517 100.082875) - (xy 175.998578 100.311708) - (xy 175.997035 100.321455) - (xy 175.97857 100.55607) - (xy 175.97857 100.56593) - (xy 174.02343 100.56593) - (xy 174.02343 100.55607) - (xy 174.004965 100.321455) - (xy 174.003422 100.311708) - (xy 173.948483 100.082875) - (xy 173.945434 100.07349) - (xy 173.855375 99.856067) - (xy 173.850893 99.847272) - (xy 173.739928 99.666195) - (xy 173.72947 99.656733) - (xy 173.720694 99.660516) - (xy 172.833022 100.548188) - (xy 172.825408 100.562132) - (xy 172.095356 100.562132) - (xy 172.096592 100.559868) - (xy 172.096461 100.558035) - (xy 172.09221 100.55142) - (xy 171.20435 99.66356) - (xy 171.19197 99.6568) - (xy 171.18432 99.662527) - (xy 171.071107 99.847272) - (xy 171.066625 99.856067) - (xy 170.976566 100.07349) - (xy 170.973517 100.082875) - (xy 170.918578 100.311708) - (xy 170.917035 100.321455) - (xy 170.89857 100.55607) - (xy 170.89857 100.56593) - (xy 142.9745 100.56593) - (xy 142.9745 99.781866) - (xy 142.967745 99.719684) - (xy 142.916615 99.583295) - (xy 142.829261 99.466739) - (xy 142.798328 99.443556) - (xy 142.719887 99.384767) - (xy 142.719884 99.384765) - (xy 142.712705 99.379385) - (xy 142.704302 99.376235) - (xy 142.696426 99.371923) - (xy 142.698063 99.368932) - (xy 142.654487 99.33618) - (xy 142.629804 99.269612) - (xy 142.6295 99.260865) - (xy 142.6295 97.155) - (xy 143.936654 97.155) - (xy 143.936924 97.159119) - (xy 143.95419 97.422548) - (xy 143.956017 97.450426) - (xy 143.956819 97.454459) - (xy 143.95682 97.454465) - (xy 144.01185 97.731114) - (xy 144.013776 97.740797) - (xy 144.015103 97.744706) - (xy 144.015104 97.74471) - (xy 144.105525 98.011081) - (xy 144.108941 98.021145) - (xy 144.159755 98.124185) - (xy 144.213228 98.232617) - (xy 144.239885 98.286673) - (xy 144.259816 98.316502) - (xy 144.331375 98.423597) - (xy 144.404367 98.532838) - (xy 144.407081 98.535932) - (xy 144.407085 98.535938) - (xy 144.573604 98.725815) - (xy 144.599573 98.755427) - (xy 144.602662 98.758136) + (xy 151.276769 93.215754) + (xy 151.276257 93.216504) + (xy 151.221346 93.261507) + (xy 151.172169 93.2715) + (xy 145.824912 93.2715) + (xy 145.816342 93.271208) + (xy 145.766224 93.267791) + (xy 145.76622 93.267791) + (xy 145.758648 93.267275) + (xy 145.751171 93.26858) + (xy 145.75117 93.26858) + (xy 145.724692 93.273201) + (xy 145.695697 93.278262) + (xy 145.689179 93.279223) + (xy 145.625758 93.286898) + (xy 145.618657 93.289581) + (xy 145.616048 93.290222) + (xy 145.599738 93.294685) + (xy 145.597202 93.29545) + (xy 145.589716 93.296757) + (xy 145.582759 93.299811) + (xy 145.531205 93.322442) + (xy 145.525101 93.324933) + (xy 145.465344 93.347513) + (xy 145.459081 93.351817) + (xy 145.456715 93.353054) + (xy 145.441903 93.361299) + (xy 145.439649 93.362632) + (xy 145.432695 93.365685) + (xy 145.381998 93.404587) + (xy 145.376668 93.408459) + (xy 145.33028 93.440339) + (xy 145.330275 93.440344) + (xy 145.324019 93.444643) + (xy 145.318968 93.450313) + (xy 145.318966 93.450314) + (xy 145.282565 93.49117) + (xy 145.277584 93.496446) + (xy 143.28348 95.49055) + (xy 143.277215 95.496404) + (xy 143.233615 95.534439) + (xy 143.219465 95.554573) + (xy 143.196872 95.586719) + (xy 143.192939 95.592014) + (xy 143.153524 95.642282) + (xy 143.150401 95.649198) + (xy 143.149017 95.651484) + (xy 143.140643 95.666165) + (xy 143.139378 95.668525) + (xy 143.13501 95.674739) + (xy 143.13225 95.681818) + (xy 143.132249 95.68182) + (xy 143.111798 95.734275) + (xy 143.109247 95.740344) + (xy 143.082955 95.798573) + (xy 143.081571 95.80604) + (xy 143.08077 95.808595) + (xy 143.076141 95.824848) + (xy 143.075478 95.827428) + (xy 143.072718 95.834509) + (xy 143.071727 95.84204) + (xy 143.071726 95.842042) + (xy 143.064379 95.897852) + (xy 143.063348 95.904359) + (xy 143.051704 95.967186) + (xy 143.052141 95.974766) + (xy 143.052141 95.974767) + (xy 143.055291 96.029392) + (xy 143.0555 96.036646) + (xy 143.0555 98.586338) + (xy 143.035498 98.654459) + (xy 143.018596 98.675433) + (xy 142.509435 99.184595) + (xy 142.447122 99.21862) + (xy 142.420339 99.2215) + (xy 141.867866 99.2215) + (xy 141.805684 99.228255) + (xy 141.669295 99.279385) + (xy 141.552739 99.366739) + (xy 141.465385 99.483295) + (xy 141.414255 99.619684) + (xy 141.4075 99.681866) + (xy 141.4075 100.978134) + (xy 141.414255 101.040316) + (xy 141.465385 101.176705) + (xy 141.552739 101.293261) + (xy 141.669295 101.380615) + (xy 141.805684 101.431745) + (xy 141.867866 101.4385) + (xy 142.864134 101.4385) + (xy 142.926316 101.431745) + (xy 143.062705 101.380615) + (xy 143.179261 101.293261) + (xy 143.266615 101.176705) + (xy 143.317745 101.040316) + (xy 143.3245 100.978134) + (xy 143.3245 100.56593) + (xy 170.94857 100.56593) + (xy 170.967035 100.800545) + (xy 170.968578 100.810292) + (xy 171.023517 101.039125) + (xy 171.026566 101.04851) + (xy 171.116625 101.265933) + (xy 171.121107 101.274728) + (xy 171.232072 101.455805) + (xy 171.24253 101.465267) + (xy 171.251306 101.461484) + (xy 172.138978 100.573812) + (xy 172.145356 100.562132) + (xy 172.875408 100.562132) + (xy 172.875539 100.563965) + (xy 172.87979 100.57058) + (xy 173.76765 101.45844) + (xy 173.78003 101.4652) + (xy 173.78768 101.459473) + (xy 173.900893 101.274728) + (xy 173.905375 101.265933) + (xy 173.995434 101.04851) + (xy 173.998483 101.039125) + (xy 174.053422 100.810292) + (xy 174.054965 100.800545) + (xy 174.07343 100.56593) + (xy 176.02857 100.56593) + (xy 176.047035 100.800545) + (xy 176.048578 100.810292) + (xy 176.103517 101.039125) + (xy 176.106566 101.04851) + (xy 176.196625 101.265933) + (xy 176.201107 101.274728) + (xy 176.312072 101.455805) + (xy 176.32253 101.465267) + (xy 176.331306 101.461484) + (xy 177.218978 100.573812) + (xy 177.225356 100.562132) + (xy 177.955408 100.562132) + (xy 177.955539 100.563965) + (xy 177.95979 100.57058) + (xy 178.84765 101.45844) + (xy 178.86003 101.4652) + (xy 178.86768 101.459473) + (xy 178.980893 101.274728) + (xy 178.985375 101.265933) + (xy 179.075434 101.04851) + (xy 179.078483 101.039125) + (xy 179.133422 100.810292) + (xy 179.134965 100.800545) + (xy 179.15343 100.56593) + (xy 179.15343 100.55607) + (xy 179.134965 100.321455) + (xy 179.133422 100.311708) + (xy 179.078483 100.082875) + (xy 179.075434 100.07349) + (xy 178.985375 99.856067) + (xy 178.980893 99.847272) + (xy 178.869928 99.666195) + (xy 178.85947 99.656733) + (xy 178.850694 99.660516) + (xy 177.963022 100.548188) + (xy 177.955408 100.562132) + (xy 177.225356 100.562132) + (xy 177.226592 100.559868) + (xy 177.226461 100.558035) + (xy 177.22221 100.55142) + (xy 176.33435 99.66356) + (xy 176.32197 99.6568) + (xy 176.31432 99.662527) + (xy 176.201107 99.847272) + (xy 176.196625 99.856067) + (xy 176.106566 100.07349) + (xy 176.103517 100.082875) + (xy 176.048578 100.311708) + (xy 176.047035 100.321455) + (xy 176.02857 100.55607) + (xy 176.02857 100.56593) + (xy 174.07343 100.56593) + (xy 174.07343 100.55607) + (xy 174.054965 100.321455) + (xy 174.053422 100.311708) + (xy 173.998483 100.082875) + (xy 173.995434 100.07349) + (xy 173.905375 99.856067) + (xy 173.900893 99.847272) + (xy 173.789928 99.666195) + (xy 173.77947 99.656733) + (xy 173.770694 99.660516) + (xy 172.883022 100.548188) + (xy 172.875408 100.562132) + (xy 172.145356 100.562132) + (xy 172.146592 100.559868) + (xy 172.146461 100.558035) + (xy 172.14221 100.55142) + (xy 171.25435 99.66356) + (xy 171.24197 99.6568) + (xy 171.23432 99.662527) + (xy 171.121107 99.847272) + (xy 171.116625 99.856067) + (xy 171.026566 100.07349) + (xy 171.023517 100.082875) + (xy 170.968578 100.311708) + (xy 170.967035 100.321455) + (xy 170.94857 100.55607) + (xy 170.94857 100.56593) + (xy 143.3245 100.56593) + (xy 143.3245 100.42566) + (xy 143.344502 100.357539) + (xy 143.361405 100.336565) + (xy 144.24452 99.45345) + (xy 144.250785 99.447596) + (xy 144.261799 99.437988) + (xy 144.294385 99.409561) + (xy 144.331114 99.3573) + (xy 144.335046 99.352005) + (xy 144.359738 99.320515) + (xy 144.374477 99.301718) + (xy 144.377602 99.294796) + (xy 144.378964 99.292548) + (xy 144.387368 99.277815) + (xy 144.388622 99.275476) + (xy 144.39299 99.269261) + (xy 144.395749 99.262185) + (xy 144.395751 99.262181) + (xy 144.416202 99.209726) + (xy 144.418758 99.203646) + (xy 144.441918 99.152351) + (xy 144.445045 99.145426) + (xy 144.446429 99.137955) + (xy 144.44723 99.135401) + (xy 144.451867 99.119122) + (xy 144.452523 99.116567) + (xy 144.455282 99.109491) + (xy 144.463621 99.046149) + (xy 144.464653 99.039633) + (xy 144.474912 98.98428) + (xy 144.476296 98.976813) + (xy 144.473603 98.930113) + (xy 144.48965 98.860955) + (xy 144.54054 98.81145) + (xy 144.610116 98.797317) + (xy 144.676288 98.823043) + (xy 144.682472 98.828128) (xy 144.819062 98.947915) (xy 144.819068 98.947919) (xy 144.822162 98.950633) @@ -4390,7 +4402,7 @@ (xy 145.068327 99.115115) (xy 145.072026 99.116939) (xy 145.072031 99.116942) - (xy 145.098324 99.129908) + (xy 145.143834 99.152351) (xy 145.333855 99.246059) (xy 145.33776 99.247384) (xy 145.337761 99.247385) @@ -4420,7 +4432,7 @@ (xy 147.062239 99.247385) (xy 147.06224 99.247384) (xy 147.066145 99.246059) - (xy 147.301676 99.129908) + (xy 147.256166 99.152351) (xy 147.327969 99.116942) (xy 147.327974 99.116939) (xy 147.331673 99.115115) @@ -4429,13 +4441,13 @@ (xy 151.037251 99.026695) (xy 151.037548 99.031848) (xy 151.037548 99.031851) - (xy 151.048707 99.225388) + (xy 151.046355 99.184595) (xy 151.05011 99.249715) (xy 151.051247 99.254761) (xy 151.051248 99.254767) - (xy 151.066371 99.321869) + (xy 151.067214 99.325611) (xy 151.099222 99.467639) - (xy 151.146185 99.583295) + (xy 151.138646 99.56473) (xy 151.179847 99.666195) (xy 151.183266 99.674616) (xy 151.299987 99.865088) @@ -4467,22 +4479,25 @@ (xy 153.497594 99.860689) (xy 153.565435 99.766277) (xy 153.568453 99.762077) - (xy 153.617654 99.662527) + (xy 153.608096 99.681866) (xy 153.665136 99.566453) (xy 153.665137 99.566451) (xy 153.66743 99.561811) - (xy 153.72122 99.384767) + (xy 153.726698 99.366739) (xy 153.730865 99.353023) (xy 153.730865 99.353021) (xy 153.73237 99.348069) (xy 153.761529 99.12659) - (xy 153.761765 99.116942) + (xy 153.761637 99.122183) (xy 153.763074 99.063365) (xy 153.763074 99.063361) (xy 153.763156 99.06) (xy 153.744852 98.837361) (xy 153.690431 98.620702) (xy 153.601354 98.41584) + (xy 153.502562 98.263131) + (xy 153.482822 98.232617) + (xy 153.48282 98.232614) (xy 153.480014 98.228277) (xy 153.32967 98.063051) (xy 153.325619 98.059852) @@ -4513,11 +4528,12 @@ (xy 151.673607 97.906507) (xy 151.669474 97.90961) (xy 151.669471 97.909612) - (xy 151.515998 98.024843) + (xy 151.520923 98.021145) (xy 151.494965 98.040635) - (xy 151.415123 98.124185) - (xy 151.38078 98.160123) (xy 151.340629 98.202138) + (xy 151.337715 98.20641) + (xy 151.337714 98.206411) + (xy 151.305271 98.253971) (xy 151.214743 98.38668) (xy 151.199003 98.42059) (xy 151.13463 98.55927) @@ -4539,10 +4555,10 @@ (xy 148.068626 98.423597) (xy 148.140184 98.316502) (xy 148.160115 98.286673) - (xy 148.186773 98.232617) - (xy 148.240245 98.124185) + (xy 148.17179 98.263) + (xy 148.271973 98.059848) (xy 148.291059 98.021145) - (xy 148.294475 98.011081) + (xy 148.298857 97.998172) (xy 148.384896 97.74471) (xy 148.384897 97.744706) (xy 148.386224 97.740797) @@ -4621,7 +4637,7 @@ (xy 148.292385 96.292761) (xy 148.292384 96.29276) (xy 148.291059 96.288855) - (xy 148.186152 96.076124) + (xy 148.202963 96.110214) (xy 148.161942 96.027031) (xy 148.161939 96.027026) (xy 148.160115 96.023327) @@ -4651,77 +4667,16 @@ (xy 146.785797 94.968776) (xy 146.781753 94.967972) (xy 146.781747 94.96797) - (xy 146.499465 94.91182) - (xy 146.499459 94.911819) - (xy 146.495426 94.911017) - (xy 146.491321 94.910748) - (xy 146.491314 94.910747) - (xy 146.25456 94.89523) - (xy 146.197621 94.874378) - (xy 146.172697 94.890396) - (xy 146.14544 94.89523) - (xy 145.908686 94.910747) - (xy 145.908679 94.910748) - (xy 145.904574 94.911017) - (xy 145.900541 94.911819) - (xy 145.900535 94.91182) - (xy 145.618253 94.96797) - (xy 145.618247 94.967972) - (xy 145.614203 94.968776) - (xy 145.610294 94.970103) - (xy 145.61029 94.970104) - (xy 145.411394 95.03762) - (xy 145.333855 95.063941) - (xy 145.208313 95.125852) - (xy 145.072031 95.193058) - (xy 145.072026 95.193061) - (xy 145.068327 95.194885) - (xy 145.064894 95.197179) - (xy 144.825593 95.357074) - (xy 144.825588 95.357078) - (xy 144.822162 95.359367) - (xy 144.819068 95.362081) - (xy 144.819062 95.362085) - (xy 144.677845 95.48593) - (xy 144.599573 95.554573) - (xy 144.596864 95.557662) - (xy 144.407085 95.774062) - (xy 144.407081 95.774068) - (xy 144.404367 95.777162) - (xy 144.402078 95.780588) - (xy 144.402074 95.780593) - (xy 144.29814 95.936142) - (xy 144.239885 96.023327) - (xy 144.238061 96.027026) - (xy 144.238058 96.027031) - (xy 144.213848 96.076124) - (xy 144.108941 96.288855) - (xy 144.107616 96.29276) - (xy 144.107615 96.292761) - (xy 144.017266 96.558923) - (xy 144.013776 96.569203) - (xy 144.012972 96.573247) - (xy 144.01297 96.573253) - (xy 143.965277 96.813023) - (xy 143.956017 96.859574) - (xy 143.955748 96.863679) - (xy 143.955747 96.863686) - (xy 143.938319 97.129603) - (xy 143.936654 97.155) - (xy 142.6295 97.155) - (xy 142.6295 96.882895) - (xy 142.649502 96.814774) - (xy 142.666405 96.7938) - (xy 144.779801 94.680405) - (xy 144.842113 94.646379) - (xy 144.868896 94.6435) - (xy 146.137199 94.6435) - (xy 146.204888 94.663375) - (xy 146.235286 94.646541) - (xy 146.262801 94.6435) - (xy 151.142658 94.6435) - (xy 151.210779 94.663502) - (xy 151.250091 94.703665) + (xy 146.631474 94.938079) + (xy 146.568565 94.905171) + (xy 146.533433 94.843476) + (xy 146.537233 94.772582) + (xy 146.578759 94.714996) + (xy 146.644826 94.689001) + (xy 146.656056 94.6885) + (xy 151.170234 94.6885) + (xy 151.238355 94.708502) + (xy 151.277667 94.748665) (xy 151.299987 94.785088) (xy 151.44625 94.953938) (xy 151.618126 95.096632) @@ -4752,7 +4707,7 @@ (xy 153.156761 95.108978) (xy 153.27986 95.021173) (xy 153.332441 94.968776) - (xy 153.390402 94.911017) + (xy 153.434435 94.867137) (xy 153.438096 94.863489) (xy 153.497594 94.780689) (xy 153.565435 94.686277) @@ -4796,7 +4751,7 @@ (xy 153.497594 92.240689) (xy 153.565435 92.146277) (xy 153.568453 92.142077) - (xy 153.577634 92.123502) + (xy 153.571751 92.135405) (xy 153.665136 91.946453) (xy 153.665137 91.946451) (xy 153.66743 91.941811) @@ -4821,10 +4776,10 @@ (xy 153.048312 90.161921) (xy 153.073428 90.095516) (xy 153.10078 90.068909) - (xy 153.169499 90.019892) + (xy 153.165159 90.022988) (xy 153.27986 89.941173) - (xy 153.312081 89.909065) - (xy 153.363503 89.857822) + (xy 153.331582 89.889632) + (xy 153.362566 89.858756) (xy 153.438096 89.783489) (xy 153.442329 89.777599) (xy 153.565435 89.606277) @@ -4844,59 +4799,21 @@ (xy 153.466368 88.010358) (xy 153.486164 87.942177) (xy 153.503272 87.920883) - (xy 160.74375 80.680405) - (xy 160.806062 80.646379) - (xy 160.832845 80.6435) - (xy 166.241527 80.6435) - (xy 166.309648 80.663502) - (xy 166.356141 80.717158) - (xy 166.366245 80.787432) - (xy 166.360745 80.809182) - (xy 166.360688 80.809305) - (xy 166.300989 81.02457) - (xy 166.277251 81.246695) - (xy 166.277548 81.251848) - (xy 166.277548 81.251851) - (xy 166.285889 81.396507) - (xy 166.29011 81.469715) - (xy 166.291247 81.474761) - (xy 166.291248 81.474767) - (xy 166.311119 81.562939) - (xy 166.339222 81.687639) - (xy 166.400369 81.838227) - (xy 166.417167 81.879595) - (xy 166.423266 81.894616) - (xy 166.474019 81.977438) - (xy 166.525475 82.061406) - (xy 166.539987 82.085088) - (xy 166.68625 82.253938) - (xy 166.858126 82.396632) - (xy 166.928595 82.437811) - (xy 166.931445 82.439476) - (xy 166.980169 82.491114) - (xy 166.99324 82.560897) - (xy 166.966509 82.626669) - (xy 166.926055 82.660027) - (xy 166.913607 82.666507) - (xy 166.909474 82.66961) - (xy 166.909471 82.669612) - (xy 166.7391 82.79753) - (xy 166.734965 82.800635) - (xy 166.731393 82.804373) - (xy 166.593667 82.948495) - (xy 166.580629 82.962138) - (xy 166.577715 82.96641) - (xy 166.577714 82.966411) - (xy 166.532798 83.032255) - (xy 166.454743 83.14668) - (xy 166.422842 83.215405) - (xy 166.369727 83.329833) + (xy 155.832015 85.592141) + (xy 158.203751 83.220405) + (xy 158.266063 83.186379) + (xy 158.292846 83.1835) + (xy 166.241527 83.1835) + (xy 166.309648 83.203502) + (xy 166.356141 83.257158) + (xy 166.366245 83.327432) + (xy 166.360745 83.349182) (xy 166.360688 83.349305) (xy 166.300989 83.56457) (xy 166.277251 83.786695) (xy 166.277548 83.791848) (xy 166.277548 83.791851) - (xy 166.283011 83.88659) + (xy 166.285427 83.928498) (xy 166.29011 84.009715) (xy 166.291247 84.014761) (xy 166.291248 84.014767) @@ -4905,12 +4822,12 @@ (xy 166.377461 84.321811) (xy 166.417167 84.419595) (xy 166.423266 84.434616) - (xy 166.454872 84.486192) - (xy 166.535096 84.617106) + (xy 166.438049 84.458739) + (xy 166.525475 84.601406) (xy 166.539987 84.625088) (xy 166.68625 84.793938) (xy 166.858126 84.936632) - (xy 166.884872 84.952261) + (xy 166.867083 84.941866) (xy 166.931445 84.979476) (xy 166.980169 85.031114) (xy 166.99324 85.100897) @@ -4921,23 +4838,26 @@ (xy 166.909471 85.209612) (xy 166.7391 85.33753) (xy 166.734965 85.340635) - (xy 166.694466 85.383015) + (xy 166.694458 85.383023) (xy 166.593667 85.488495) (xy 166.580629 85.502138) + (xy 166.577715 85.50641) + (xy 166.577714 85.506411) + (xy 166.532798 85.572255) (xy 166.454743 85.68668) (xy 166.360688 85.889305) (xy 166.300989 86.10457) (xy 166.277251 86.326695) (xy 166.277548 86.331848) (xy 166.277548 86.331851) - (xy 166.287641 86.50689) + (xy 166.284424 86.451097) (xy 166.29011 86.549715) (xy 166.291247 86.554761) (xy 166.291248 86.554767) (xy 166.293797 86.566077) (xy 166.339222 86.767639) - (xy 166.399014 86.91489) - (xy 166.416662 86.958351) + (xy 166.385017 86.880419) + (xy 166.4109 86.944161) (xy 166.423266 86.974616) (xy 166.447673 87.014444) (xy 166.528778 87.146796) @@ -4981,7 +4901,7 @@ (xy 166.539987 89.705088) (xy 166.68625 89.873938) (xy 166.858126 90.016632) - (xy 166.909648 90.046739) + (xy 166.869003 90.022988) (xy 166.931445 90.059476) (xy 166.980169 90.111114) (xy 166.99324 90.180897) @@ -4999,7 +4919,7 @@ (xy 166.577714 90.586411) (xy 166.557189 90.6165) (xy 166.454743 90.76668) - (xy 166.410931 90.861065) + (xy 166.435367 90.808423) (xy 166.36375 90.962709) (xy 166.360688 90.969305) (xy 166.300989 91.18457) @@ -5013,7 +4933,7 @@ (xy 166.306626 91.703) (xy 166.339222 91.847639) (xy 166.423266 92.054616) - (xy 166.465479 92.123502) + (xy 166.425965 92.05902) (xy 166.521262 92.214531) (xy 166.539987 92.245088) (xy 166.68625 92.413938) @@ -5036,7 +4956,7 @@ (xy 166.577714 93.126411) (xy 166.516303 93.216436) (xy 166.454743 93.30668) - (xy 166.440743 93.336841) + (xy 166.424183 93.372516) (xy 166.36686 93.496009) (xy 166.360688 93.509305) (xy 166.300989 93.72457) @@ -5067,7 +4987,7 @@ (xy 166.913607 95.366507) (xy 166.909474 95.36961) (xy 166.909471 95.369612) - (xy 166.757167 95.483965) + (xy 166.748357 95.49058) (xy 166.734965 95.500635) (xy 166.580629 95.662138) (xy 166.454743 95.84668) @@ -5078,7 +4998,7 @@ (xy 166.277251 96.486695) (xy 166.277548 96.491848) (xy 166.277548 96.491851) - (xy 166.28418 96.606866) + (xy 166.283011 96.58659) (xy 166.29011 96.709715) (xy 166.291247 96.714761) (xy 166.291248 96.714767) @@ -5094,15 +5014,15 @@ (xy 166.99324 97.800897) (xy 166.966509 97.866669) (xy 166.926055 97.900027) - (xy 166.922832 97.901705) (xy 166.913607 97.906507) (xy 166.909474 97.90961) (xy 166.909471 97.909612) - (xy 166.755998 98.024843) + (xy 166.760923 98.021145) (xy 166.734965 98.040635) - (xy 166.655123 98.124185) - (xy 166.62078 98.160123) (xy 166.580629 98.202138) + (xy 166.577715 98.20641) + (xy 166.577714 98.206411) + (xy 166.545271 98.253971) (xy 166.454743 98.38668) (xy 166.439003 98.42059) (xy 166.37463 98.55927) @@ -5111,13 +5031,13 @@ (xy 166.277251 99.026695) (xy 166.277548 99.031848) (xy 166.277548 99.031851) - (xy 166.288707 99.225388) + (xy 166.286355 99.184595) (xy 166.29011 99.249715) (xy 166.291247 99.254761) (xy 166.291248 99.254767) - (xy 166.306371 99.321869) + (xy 166.307214 99.325611) (xy 166.339222 99.467639) - (xy 166.386185 99.583295) + (xy 166.378646 99.56473) (xy 166.419847 99.666195) (xy 166.423266 99.674616) (xy 166.539987 99.865088) @@ -5149,76 +5069,79 @@ (xy 168.737594 99.860689) (xy 168.805435 99.766277) (xy 168.808453 99.762077) - (xy 168.857654 99.662527) + (xy 168.848096 99.681866) (xy 168.905136 99.566453) (xy 168.905137 99.566451) (xy 168.90743 99.561811) - (xy 168.96122 99.384767) + (xy 168.966698 99.366739) (xy 168.970865 99.353023) (xy 168.970865 99.353021) (xy 168.97237 99.348069) (xy 168.979682 99.29253) - (xy 171.556733 99.29253) - (xy 171.560516 99.301306) - (xy 172.448188 100.188978) - (xy 172.462132 100.196592) - (xy 172.463965 100.196461) - (xy 172.47058 100.19221) - (xy 173.35844 99.30435) - (xy 173.364894 99.29253) - (xy 176.636733 99.29253) - (xy 176.640516 99.301306) - (xy 177.528188 100.188978) - (xy 177.542132 100.196592) - (xy 177.543965 100.196461) - (xy 177.55058 100.19221) - (xy 178.43844 99.30435) - (xy 178.4452 99.29197) - (xy 178.439473 99.28432) - (xy 178.254728 99.171107) - (xy 178.245933 99.166625) - (xy 178.02851 99.076566) - (xy 178.019125 99.073517) - (xy 177.790292 99.018578) - (xy 177.780545 99.017035) - (xy 177.54593 98.99857) - (xy 177.53607 98.99857) - (xy 177.301455 99.017035) - (xy 177.291708 99.018578) - (xy 177.062875 99.073517) - (xy 177.05349 99.076566) - (xy 176.836067 99.166625) - (xy 176.827272 99.171107) - (xy 176.646195 99.282072) - (xy 176.636733 99.29253) - (xy 173.364894 99.29253) - (xy 173.3652 99.29197) - (xy 173.359473 99.28432) - (xy 173.174728 99.171107) - (xy 173.165933 99.166625) - (xy 172.94851 99.076566) - (xy 172.939125 99.073517) - (xy 172.710292 99.018578) - (xy 172.700545 99.017035) - (xy 172.46593 98.99857) - (xy 172.45607 98.99857) - (xy 172.221455 99.017035) - (xy 172.211708 99.018578) - (xy 171.982875 99.073517) - (xy 171.97349 99.076566) - (xy 171.756067 99.166625) - (xy 171.747272 99.171107) - (xy 171.566195 99.282072) - (xy 171.556733 99.29253) + (xy 171.606733 99.29253) + (xy 171.610516 99.301306) + (xy 172.498188 100.188978) + (xy 172.512132 100.196592) + (xy 172.513965 100.196461) + (xy 172.52058 100.19221) + (xy 173.40844 99.30435) + (xy 173.414894 99.29253) + (xy 176.686733 99.29253) + (xy 176.690516 99.301306) + (xy 177.578188 100.188978) + (xy 177.592132 100.196592) + (xy 177.593965 100.196461) + (xy 177.60058 100.19221) + (xy 178.48844 99.30435) + (xy 178.4952 99.29197) + (xy 178.489473 99.28432) + (xy 178.304728 99.171107) + (xy 178.295933 99.166625) + (xy 178.07851 99.076566) + (xy 178.069125 99.073517) + (xy 177.840292 99.018578) + (xy 177.830545 99.017035) + (xy 177.59593 98.99857) + (xy 177.58607 98.99857) + (xy 177.351455 99.017035) + (xy 177.341708 99.018578) + (xy 177.112875 99.073517) + (xy 177.10349 99.076566) + (xy 176.886067 99.166625) + (xy 176.877272 99.171107) + (xy 176.696195 99.282072) + (xy 176.686733 99.29253) + (xy 173.414894 99.29253) + (xy 173.4152 99.29197) + (xy 173.409473 99.28432) + (xy 173.224728 99.171107) + (xy 173.215933 99.166625) + (xy 172.99851 99.076566) + (xy 172.989125 99.073517) + (xy 172.760292 99.018578) + (xy 172.750545 99.017035) + (xy 172.51593 98.99857) + (xy 172.50607 98.99857) + (xy 172.271455 99.017035) + (xy 172.261708 99.018578) + (xy 172.032875 99.073517) + (xy 172.02349 99.076566) + (xy 171.806067 99.166625) + (xy 171.797272 99.171107) + (xy 171.616195 99.282072) + (xy 171.606733 99.29253) (xy 168.979682 99.29253) (xy 169.001529 99.12659) - (xy 169.001765 99.116942) + (xy 169.001637 99.122183) (xy 169.003074 99.063365) (xy 169.003074 99.063361) (xy 169.003156 99.06) (xy 168.984852 98.837361) (xy 168.930431 98.620702) (xy 168.841354 98.41584) + (xy 168.742562 98.263131) + (xy 168.722822 98.232617) + (xy 168.72282 98.232614) (xy 168.720014 98.228277) (xy 168.56967 98.063051) (xy 168.565619 98.059852) @@ -5243,177 +5166,180 @@ (xy 168.90743 97.021811) (xy 168.97237 96.808069) (xy 168.980011 96.75003) - (xy 171.5568 96.75003) - (xy 171.562527 96.75768) - (xy 171.747272 96.870893) - (xy 171.756067 96.875375) - (xy 171.97349 96.965434) - (xy 171.982875 96.968483) - (xy 172.211708 97.023422) - (xy 172.221455 97.024965) - (xy 172.45607 97.04343) - (xy 172.46593 97.04343) - (xy 172.700545 97.024965) - (xy 172.710292 97.023422) - (xy 172.939125 96.968483) - (xy 172.94851 96.965434) - (xy 173.165933 96.875375) - (xy 173.174728 96.870893) - (xy 173.355805 96.759928) - (xy 173.36476 96.75003) - (xy 176.6368 96.75003) - (xy 176.642527 96.75768) - (xy 176.827272 96.870893) - (xy 176.836067 96.875375) - (xy 177.05349 96.965434) - (xy 177.062875 96.968483) - (xy 177.291708 97.023422) - (xy 177.301455 97.024965) - (xy 177.53607 97.04343) - (xy 177.54593 97.04343) - (xy 177.780545 97.024965) - (xy 177.790292 97.023422) - (xy 178.019125 96.968483) - (xy 178.02851 96.965434) - (xy 178.245933 96.875375) - (xy 178.254728 96.870893) - (xy 178.435805 96.759928) - (xy 178.445267 96.74947) - (xy 178.441484 96.740694) - (xy 177.553812 95.853022) - (xy 177.539868 95.845408) - (xy 177.538035 95.845539) - (xy 177.53142 95.84979) - (xy 176.64356 96.73765) - (xy 176.6368 96.75003) - (xy 173.36476 96.75003) - (xy 173.365267 96.74947) - (xy 173.361484 96.740694) - (xy 172.473812 95.853022) - (xy 172.459868 95.845408) - (xy 172.458035 95.845539) - (xy 172.45142 95.84979) - (xy 171.56356 96.73765) - (xy 171.5568 96.75003) + (xy 171.6068 96.75003) + (xy 171.612527 96.75768) + (xy 171.797272 96.870893) + (xy 171.806067 96.875375) + (xy 172.02349 96.965434) + (xy 172.032875 96.968483) + (xy 172.261708 97.023422) + (xy 172.271455 97.024965) + (xy 172.50607 97.04343) + (xy 172.51593 97.04343) + (xy 172.750545 97.024965) + (xy 172.760292 97.023422) + (xy 172.989125 96.968483) + (xy 172.99851 96.965434) + (xy 173.215933 96.875375) + (xy 173.224728 96.870893) + (xy 173.405805 96.759928) + (xy 173.41476 96.75003) + (xy 176.6868 96.75003) + (xy 176.692527 96.75768) + (xy 176.877272 96.870893) + (xy 176.886067 96.875375) + (xy 177.10349 96.965434) + (xy 177.112875 96.968483) + (xy 177.341708 97.023422) + (xy 177.351455 97.024965) + (xy 177.58607 97.04343) + (xy 177.59593 97.04343) + (xy 177.830545 97.024965) + (xy 177.840292 97.023422) + (xy 178.069125 96.968483) + (xy 178.07851 96.965434) + (xy 178.295933 96.875375) + (xy 178.304728 96.870893) + (xy 178.485805 96.759928) + (xy 178.495267 96.74947) + (xy 178.491484 96.740694) + (xy 177.603812 95.853022) + (xy 177.589868 95.845408) + (xy 177.588035 95.845539) + (xy 177.58142 95.84979) + (xy 176.69356 96.73765) + (xy 176.6868 96.75003) + (xy 173.41476 96.75003) + (xy 173.415267 96.74947) + (xy 173.411484 96.740694) + (xy 172.523812 95.853022) + (xy 172.509868 95.845408) + (xy 172.508035 95.845539) + (xy 172.50142 95.84979) + (xy 171.61356 96.73765) + (xy 171.6068 96.75003) (xy 168.980011 96.75003) (xy 169.001529 96.58659) - (xy 169.001855 96.573253) + (xy 169.001954 96.569203) (xy 169.003074 96.523365) (xy 169.003074 96.523361) (xy 169.003156 96.52) (xy 168.984852 96.297361) (xy 168.930431 96.080702) (xy 168.841354 95.87584) + (xy 168.751758 95.737345) + (xy 168.722822 95.692617) + (xy 168.72282 95.692614) (xy 168.720014 95.688277) (xy 168.56967 95.523051) (xy 168.565619 95.519852) (xy 168.565615 95.519848) (xy 168.522668 95.48593) - (xy 170.89857 95.48593) - (xy 170.917035 95.720545) - (xy 170.918578 95.730292) - (xy 170.973517 95.959125) - (xy 170.976566 95.96851) - (xy 171.066625 96.185933) - (xy 171.071107 96.194728) - (xy 171.182072 96.375805) - (xy 171.19253 96.385267) - (xy 171.201306 96.381484) - (xy 172.088978 95.493812) - (xy 172.095356 95.482132) - (xy 172.825408 95.482132) - (xy 172.825539 95.483965) - (xy 172.82979 95.49058) - (xy 173.71765 96.37844) - (xy 173.73003 96.3852) - (xy 173.73768 96.379473) - (xy 173.850893 96.194728) - (xy 173.855375 96.185933) - (xy 173.945434 95.96851) - (xy 173.948483 95.959125) - (xy 174.003422 95.730292) - (xy 174.004965 95.720545) - (xy 174.02343 95.48593) - (xy 175.97857 95.48593) - (xy 175.997035 95.720545) - (xy 175.998578 95.730292) - (xy 176.053517 95.959125) - (xy 176.056566 95.96851) - (xy 176.146625 96.185933) - (xy 176.151107 96.194728) - (xy 176.262072 96.375805) - (xy 176.27253 96.385267) - (xy 176.281306 96.381484) - (xy 177.168978 95.493812) - (xy 177.175356 95.482132) - (xy 177.905408 95.482132) - (xy 177.905539 95.483965) - (xy 177.90979 95.49058) - (xy 178.79765 96.37844) - (xy 178.81003 96.3852) - (xy 178.81768 96.379473) - (xy 178.930893 96.194728) - (xy 178.935375 96.185933) - (xy 179.025434 95.96851) - (xy 179.028483 95.959125) - (xy 179.083422 95.730292) - (xy 179.084965 95.720545) - (xy 179.10343 95.48593) - (xy 179.10343 95.47607) - (xy 179.084965 95.241455) - (xy 179.083422 95.231708) - (xy 179.028483 95.002875) - (xy 179.025434 94.99349) - (xy 178.935375 94.776067) - (xy 178.930893 94.767272) - (xy 178.819928 94.586195) - (xy 178.80947 94.576733) - (xy 178.800694 94.580516) - (xy 177.913022 95.468188) - (xy 177.905408 95.482132) - (xy 177.175356 95.482132) - (xy 177.176592 95.479868) - (xy 177.176461 95.478035) - (xy 177.17221 95.47142) - (xy 176.28435 94.58356) - (xy 176.27197 94.5768) - (xy 176.26432 94.582527) - (xy 176.151107 94.767272) - (xy 176.146625 94.776067) - (xy 176.056566 94.99349) - (xy 176.053517 95.002875) - (xy 175.998578 95.231708) - (xy 175.997035 95.241455) - (xy 175.97857 95.47607) - (xy 175.97857 95.48593) - (xy 174.02343 95.48593) - (xy 174.02343 95.47607) - (xy 174.004965 95.241455) - (xy 174.003422 95.231708) - (xy 173.948483 95.002875) - (xy 173.945434 94.99349) - (xy 173.855375 94.776067) - (xy 173.850893 94.767272) - (xy 173.739928 94.586195) - (xy 173.72947 94.576733) - (xy 173.720694 94.580516) - (xy 172.833022 95.468188) - (xy 172.825408 95.482132) - (xy 172.095356 95.482132) - (xy 172.096592 95.479868) - (xy 172.096461 95.478035) - (xy 172.09221 95.47142) - (xy 171.20435 94.58356) - (xy 171.19197 94.5768) - (xy 171.18432 94.582527) - (xy 171.071107 94.767272) - (xy 171.066625 94.776067) - (xy 170.976566 94.99349) - (xy 170.973517 95.002875) - (xy 170.918578 95.231708) - (xy 170.917035 95.241455) - (xy 170.89857 95.47607) - (xy 170.89857 95.48593) + (xy 170.94857 95.48593) + (xy 170.967035 95.720545) + (xy 170.968578 95.730292) + (xy 171.023517 95.959125) + (xy 171.026566 95.96851) + (xy 171.116625 96.185933) + (xy 171.121107 96.194728) + (xy 171.232072 96.375805) + (xy 171.24253 96.385267) + (xy 171.251306 96.381484) + (xy 172.138978 95.493812) + (xy 172.145356 95.482132) + (xy 172.875408 95.482132) + (xy 172.875539 95.483965) + (xy 172.87979 95.49058) + (xy 173.76765 96.37844) + (xy 173.78003 96.3852) + (xy 173.78768 96.379473) + (xy 173.900893 96.194728) + (xy 173.905375 96.185933) + (xy 173.995434 95.96851) + (xy 173.998483 95.959125) + (xy 174.053422 95.730292) + (xy 174.054965 95.720545) + (xy 174.07343 95.48593) + (xy 176.02857 95.48593) + (xy 176.047035 95.720545) + (xy 176.048578 95.730292) + (xy 176.103517 95.959125) + (xy 176.106566 95.96851) + (xy 176.196625 96.185933) + (xy 176.201107 96.194728) + (xy 176.312072 96.375805) + (xy 176.32253 96.385267) + (xy 176.331306 96.381484) + (xy 177.218978 95.493812) + (xy 177.225356 95.482132) + (xy 177.955408 95.482132) + (xy 177.955539 95.483965) + (xy 177.95979 95.49058) + (xy 178.84765 96.37844) + (xy 178.86003 96.3852) + (xy 178.86768 96.379473) + (xy 178.980893 96.194728) + (xy 178.985375 96.185933) + (xy 179.075434 95.96851) + (xy 179.078483 95.959125) + (xy 179.133422 95.730292) + (xy 179.134965 95.720545) + (xy 179.15343 95.48593) + (xy 179.15343 95.47607) + (xy 179.134965 95.241455) + (xy 179.133422 95.231708) + (xy 179.078483 95.002875) + (xy 179.075434 94.99349) + (xy 178.985375 94.776067) + (xy 178.980893 94.767272) + (xy 178.869928 94.586195) + (xy 178.85947 94.576733) + (xy 178.850694 94.580516) + (xy 177.963022 95.468188) + (xy 177.955408 95.482132) + (xy 177.225356 95.482132) + (xy 177.226592 95.479868) + (xy 177.226461 95.478035) + (xy 177.22221 95.47142) + (xy 176.33435 94.58356) + (xy 176.32197 94.5768) + (xy 176.31432 94.582527) + (xy 176.201107 94.767272) + (xy 176.196625 94.776067) + (xy 176.106566 94.99349) + (xy 176.103517 95.002875) + (xy 176.048578 95.231708) + (xy 176.047035 95.241455) + (xy 176.02857 95.47607) + (xy 176.02857 95.48593) + (xy 174.07343 95.48593) + (xy 174.07343 95.47607) + (xy 174.054965 95.241455) + (xy 174.053422 95.231708) + (xy 173.998483 95.002875) + (xy 173.995434 94.99349) + (xy 173.905375 94.776067) + (xy 173.900893 94.767272) + (xy 173.789928 94.586195) + (xy 173.77947 94.576733) + (xy 173.770694 94.580516) + (xy 172.883022 95.468188) + (xy 172.875408 95.482132) + (xy 172.145356 95.482132) + (xy 172.146592 95.479868) + (xy 172.146461 95.478035) + (xy 172.14221 95.47142) + (xy 171.25435 94.58356) + (xy 171.24197 94.5768) + (xy 171.23432 94.582527) + (xy 171.121107 94.767272) + (xy 171.116625 94.776067) + (xy 171.026566 94.99349) + (xy 171.023517 95.002875) + (xy 170.968578 95.231708) + (xy 170.967035 95.241455) + (xy 170.94857 95.47607) + (xy 170.94857 95.48593) (xy 168.522668 95.48593) (xy 168.398414 95.3878) (xy 168.39841 95.387798) @@ -5426,7 +5352,7 @@ (xy 168.396761 95.108978) (xy 168.51986 95.021173) (xy 168.572441 94.968776) - (xy 168.630402 94.911017) + (xy 168.674435 94.867137) (xy 168.678096 94.863489) (xy 168.737594 94.780689) (xy 168.805435 94.686277) @@ -5440,58 +5366,58 @@ (xy 168.970865 94.273021) (xy 168.97237 94.268069) (xy 168.979682 94.21253) - (xy 171.556733 94.21253) - (xy 171.560516 94.221306) - (xy 172.448188 95.108978) - (xy 172.462132 95.116592) - (xy 172.463965 95.116461) - (xy 172.47058 95.11221) - (xy 173.35844 94.22435) - (xy 173.364894 94.21253) - (xy 176.636733 94.21253) - (xy 176.640516 94.221306) - (xy 177.528188 95.108978) - (xy 177.542132 95.116592) - (xy 177.543965 95.116461) - (xy 177.55058 95.11221) - (xy 178.43844 94.22435) - (xy 178.4452 94.21197) - (xy 178.439473 94.20432) - (xy 178.254728 94.091107) - (xy 178.245933 94.086625) - (xy 178.02851 93.996566) - (xy 178.019125 93.993517) - (xy 177.790292 93.938578) - (xy 177.780545 93.937035) - (xy 177.54593 93.91857) - (xy 177.53607 93.91857) - (xy 177.301455 93.937035) - (xy 177.291708 93.938578) - (xy 177.062875 93.993517) - (xy 177.05349 93.996566) - (xy 176.836067 94.086625) - (xy 176.827272 94.091107) - (xy 176.646195 94.202072) - (xy 176.636733 94.21253) - (xy 173.364894 94.21253) - (xy 173.3652 94.21197) - (xy 173.359473 94.20432) - (xy 173.174728 94.091107) - (xy 173.165933 94.086625) - (xy 172.94851 93.996566) - (xy 172.939125 93.993517) - (xy 172.710292 93.938578) - (xy 172.700545 93.937035) - (xy 172.46593 93.91857) - (xy 172.45607 93.91857) - (xy 172.221455 93.937035) - (xy 172.211708 93.938578) - (xy 171.982875 93.993517) - (xy 171.97349 93.996566) - (xy 171.756067 94.086625) - (xy 171.747272 94.091107) - (xy 171.566195 94.202072) - (xy 171.556733 94.21253) + (xy 171.606733 94.21253) + (xy 171.610516 94.221306) + (xy 172.498188 95.108978) + (xy 172.512132 95.116592) + (xy 172.513965 95.116461) + (xy 172.52058 95.11221) + (xy 173.40844 94.22435) + (xy 173.414894 94.21253) + (xy 176.686733 94.21253) + (xy 176.690516 94.221306) + (xy 177.578188 95.108978) + (xy 177.592132 95.116592) + (xy 177.593965 95.116461) + (xy 177.60058 95.11221) + (xy 178.48844 94.22435) + (xy 178.4952 94.21197) + (xy 178.489473 94.20432) + (xy 178.304728 94.091107) + (xy 178.295933 94.086625) + (xy 178.07851 93.996566) + (xy 178.069125 93.993517) + (xy 177.840292 93.938578) + (xy 177.830545 93.937035) + (xy 177.59593 93.91857) + (xy 177.58607 93.91857) + (xy 177.351455 93.937035) + (xy 177.341708 93.938578) + (xy 177.112875 93.993517) + (xy 177.10349 93.996566) + (xy 176.886067 94.086625) + (xy 176.877272 94.091107) + (xy 176.696195 94.202072) + (xy 176.686733 94.21253) + (xy 173.414894 94.21253) + (xy 173.4152 94.21197) + (xy 173.409473 94.20432) + (xy 173.224728 94.091107) + (xy 173.215933 94.086625) + (xy 172.99851 93.996566) + (xy 172.989125 93.993517) + (xy 172.760292 93.938578) + (xy 172.750545 93.937035) + (xy 172.51593 93.91857) + (xy 172.50607 93.91857) + (xy 172.271455 93.937035) + (xy 172.261708 93.938578) + (xy 172.032875 93.993517) + (xy 172.02349 93.996566) + (xy 171.806067 94.086625) + (xy 171.797272 94.091107) + (xy 171.616195 94.202072) + (xy 171.606733 94.21253) (xy 168.979682 94.21253) (xy 169.001529 94.04659) (xy 169.001611 94.04324) @@ -5524,7 +5450,7 @@ (xy 168.737594 92.240689) (xy 168.805435 92.146277) (xy 168.808453 92.142077) - (xy 168.817634 92.123502) + (xy 168.811751 92.135405) (xy 168.905136 91.946453) (xy 168.905137 91.946451) (xy 168.90743 91.941811) @@ -5611,10 +5537,10 @@ (xy 168.288312 90.161921) (xy 168.313428 90.095516) (xy 168.34078 90.068909) - (xy 168.409499 90.019892) + (xy 168.405159 90.022988) (xy 168.51986 89.941173) - (xy 168.552081 89.909065) - (xy 168.603503 89.857822) + (xy 168.571582 89.889632) + (xy 168.602566 89.858756) (xy 168.678096 89.783489) (xy 168.682329 89.777599) (xy 168.805435 89.606277) @@ -5681,53 +5607,44 @@ (xy 169.850248 86.770118) (xy 169.856276 86.772802) (xy 169.856278 86.772803) - (xy 170.014409 86.843207) + (xy 170.018681 86.845109) (xy 170.024712 86.847794) - (xy 170.103505 86.864542) - (xy 170.205056 86.886128) - (xy 170.205061 86.886128) - (xy 170.211513 86.8875) - (xy 170.22498 86.8875) - (xy 170.293101 86.907502) - (xy 170.314075 86.924405) - (xy 171.797101 88.407432) - (xy 173.247491 89.857822) - (xy 173.253344 89.864087) - (xy 173.288771 89.904698) - (xy 173.337557 89.938985) - (xy 173.342841 89.94291) - (xy 173.374789 89.96796) - (xy 173.389764 89.979702) - (xy 173.396683 89.982826) - (xy 173.402629 89.986427) - (xy 173.407786 89.989368) - (xy 173.413944 89.99267) - (xy 173.42016 89.997039) - (xy 173.427236 89.999798) - (xy 173.427238 89.999799) - (xy 173.475696 90.018692) - (xy 173.481777 90.021248) - (xy 173.536129 90.045789) - (xy 173.543595 90.047173) - (xy 173.550214 90.049247) - (xy 173.55599 90.050893) - (xy 173.562712 90.052619) - (xy 173.569782 90.055375) - (xy 173.57731 90.056366) - (xy 173.628893 90.063157) - (xy 173.635408 90.064189) - (xy 173.686564 90.07367) - (xy 173.686565 90.07367) - (xy 173.694032 90.075054) - (xy 173.701613 90.074617) - (xy 173.701614 90.074617) - (xy 173.752047 90.071709) - (xy 173.7593 90.0715) - (xy 175.757812 90.0715) - (xy 175.825933 90.091502) - (xy 175.872426 90.145158) - (xy 175.877335 90.157623) - (xy 175.88273 90.173792) + (xy 170.146585 86.873699) + (xy 170.177569 86.880285) + (xy 170.240467 86.914437) + (xy 173.214557 89.888528) + (xy 173.220411 89.894793) + (xy 173.258439 89.938385) + (xy 173.310729 89.975136) + (xy 173.315971 89.979028) + (xy 173.366282 90.018476) + (xy 173.373201 90.0216) + (xy 173.375493 90.022988) + (xy 173.390165 90.031357) + (xy 173.392525 90.032622) + (xy 173.398739 90.03699) + (xy 173.405818 90.03975) + (xy 173.40582 90.039751) + (xy 173.458275 90.060202) + (xy 173.464344 90.062753) + (xy 173.522573 90.089045) + (xy 173.530046 90.09043) + (xy 173.532612 90.091234) + (xy 173.548835 90.095855) + (xy 173.551427 90.09652) + (xy 173.558509 90.099282) + (xy 173.566044 90.100274) + (xy 173.621861 90.107622) + (xy 173.628377 90.108654) + (xy 173.64165 90.111114) + (xy 173.691186 90.120295) + (xy 173.698766 90.119858) + (xy 173.698767 90.119858) + (xy 173.75338 90.116709) + (xy 173.760633 90.1165) + (xy 175.775613 90.1165) + (xy 175.843734 90.136502) + (xy 175.884181 90.182731) (xy 175.88545 90.181946) (xy 175.978521 90.332349) (xy 175.983703 90.337522) @@ -5830,16 +5747,14 @@ (xy 185.488159 90.289612) (xy 185.575134 90.202484) (xy 185.580306 90.197303) - (xy 185.640445 90.099739) + (xy 185.640727 90.099282) (xy 185.669275 90.052969) (xy 185.669276 90.052967) (xy 185.673115 90.046739) - (xy 185.707553 89.94291) + (xy 185.707607 89.942748) (xy 185.726632 89.88539) (xy 185.726632 89.885388) (xy 185.728797 89.878862) - (xy 185.730642 89.86086) - (xy 185.739172 89.777599) (xy 185.7395 89.774401) (xy 185.739499 89.0236) (xy 185.728526 88.917833) @@ -5928,23 +5843,21 @@ (xy 176.253054 88.26645) (xy 176.102651 88.359521) (xy 175.977694 88.484697) - (xy 175.973854 88.490927) - (xy 175.906191 88.600697) (xy 175.884885 88.635261) - (xy 175.882581 88.642209) - (xy 175.882579 88.642212) - (xy 175.877286 88.658169) - (xy 175.836855 88.716528) - (xy 175.77129 88.743764) - (xy 175.757694 88.7445) - (xy 174.063021 88.7445) - (xy 173.9949 88.724498) - (xy 173.973926 88.707595) - (xy 171.249139 85.982808) - (xy 171.215113 85.920496) - (xy 171.212924 85.906883) - (xy 171.212095 85.89899) + (xy 175.883207 88.634227) + (xy 175.842867 88.680038) + (xy 175.775594 88.6995) + (xy 174.08166 88.6995) + (xy 174.013539 88.679498) + (xy 173.992565 88.662595) + (xy 171.241665 85.911695) + (xy 171.207639 85.849383) + (xy 171.20545 85.83577) + (xy 171.201232 85.795637) + (xy 171.201232 85.795635) (xy 171.200542 85.789072) + (xy 171.180528 85.727474) + (xy 171.146812 85.623709) (xy 171.141527 85.607444) (xy 171.137899 85.601159) (xy 171.101276 85.537727) @@ -6007,12 +5920,12 @@ (xy 168.406732 84.941866) (xy 168.51986 84.861173) (xy 168.54518 84.835942) - (xy 168.644349 84.737118) + (xy 168.646913 84.734563) (xy 168.678096 84.703489) - (xy 168.697475 84.676521) + (xy 168.704933 84.666142) (xy 168.805435 84.526277) (xy 168.808453 84.522077) - (xy 168.81121 84.5165) + (xy 168.814077 84.510699) (xy 168.905136 84.326453) (xy 168.905137 84.326451) (xy 168.90743 84.321811) @@ -6021,59 +5934,16 @@ (xy 169.003156 83.82) (xy 168.984852 83.597361) (xy 168.930431 83.380702) - (xy 168.841354 83.17584) - (xy 168.772162 83.068885) - (xy 168.722822 82.992617) - (xy 168.72282 82.992614) - (xy 168.720014 82.988277) - (xy 168.56967 82.823051) - (xy 168.565619 82.819852) - (xy 168.565615 82.819848) - (xy 168.398414 82.6878) - (xy 168.39841 82.687798) - (xy 168.394359 82.684598) - (xy 168.353053 82.661796) - (xy 168.303084 82.611364) - (xy 168.288312 82.541921) - (xy 168.313428 82.475516) - (xy 168.34078 82.448909) - (xy 168.384603 82.41765) - (xy 168.51986 82.321173) - (xy 168.678096 82.163489) - (xy 168.737594 82.080689) - (xy 168.805435 81.986277) - (xy 168.808453 81.982077) - (xy 168.846132 81.90584) - (xy 168.905136 81.786453) - (xy 168.905137 81.786451) - (xy 168.90743 81.781811) - (xy 168.97237 81.568069) - (xy 169.001529 81.34659) - (xy 169.00289 81.290897) - (xy 169.003074 81.283365) - (xy 169.003074 81.283361) - (xy 169.003156 81.28) - (xy 168.994749 81.177743) - (xy 169.009102 81.108213) - (xy 169.058768 81.05748) - (xy 169.127977 81.041652) - (xy 169.194758 81.065754) - (xy 169.20942 81.078324) - (xy 171.066854 82.935758) - (xy 171.10088 82.99807) - (xy 171.095815 83.068885) - (xy 171.053268 83.125721) - (xy 171.029009 83.139959) - (xy 170.999283 83.153194) - (xy 170.999275 83.153199) - (xy 170.993248 83.155882) - (xy 170.987907 83.159762) - (xy 170.987906 83.159763) - (xy 170.949073 83.187977) - (xy 170.838747 83.268134) - (xy 170.834326 83.273044) - (xy 170.834325 83.273045) - (xy 170.741666 83.375954) + (xy 168.921318 83.359743) + (xy 168.912497 83.289297) + (xy 168.943163 83.225265) + (xy 169.003579 83.187977) + (xy 169.036867 83.1835) + (xy 170.631952 83.1835) + (xy 170.700073 83.203502) + (xy 170.746566 83.257158) + (xy 170.75667 83.327432) + (xy 170.725589 83.393809) (xy 170.71096 83.410056) (xy 170.615473 83.575444) (xy 170.556458 83.757072) @@ -6090,65 +5960,74 @@ (xy 170.715379 84.488852) (xy 170.834325 84.620955) (xy 170.838747 84.625866) - (xy 170.914448 84.680866) + (xy 170.894182 84.666142) (xy 170.981106 84.729296) (xy 170.993248 84.738118) (xy 170.999276 84.740802) (xy 170.999278 84.740803) (xy 171.161681 84.813109) (xy 171.167712 84.815794) - (xy 171.256046 84.83457) + (xy 171.261112 84.835647) (xy 171.348056 84.854128) (xy 171.348061 84.854128) (xy 171.354513 84.8555) - (xy 171.36798 84.8555) - (xy 171.436101 84.875502) - (xy 171.457075 84.892405) - (xy 172.739484 86.174814) - (xy 172.745337 86.181079) - (xy 172.780771 86.221698) - (xy 172.829556 86.255984) - (xy 172.834841 86.25991) - (xy 172.875786 86.292015) - (xy 172.875792 86.292019) - (xy 172.881765 86.296702) - (xy 172.888685 86.299826) - (xy 172.894599 86.303408) - (xy 172.899836 86.306395) - (xy 172.905944 86.30967) - (xy 172.91216 86.314039) - (xy 172.919236 86.316798) - (xy 172.919242 86.316801) - (xy 172.967707 86.335696) - (xy 172.973762 86.338241) - (xy 173.028129 86.362789) - (xy 173.035594 86.364173) - (xy 173.042213 86.366247) - (xy 173.047963 86.367885) - (xy 173.054704 86.369615) - (xy 173.061782 86.372375) - (xy 173.069318 86.373367) - (xy 173.120888 86.380156) - (xy 173.127405 86.381188) - (xy 173.161331 86.387476) - (xy 173.186033 86.392054) - (xy 173.193613 86.391617) - (xy 173.193614 86.391617) - (xy 173.244048 86.388709) - (xy 173.251301 86.3885) - (xy 175.757812 86.3885) - (xy 175.825933 86.408502) - (xy 175.872426 86.462158) - (xy 175.877335 86.474623) + (xy 171.37505 84.8555) + (xy 171.443171 84.875502) + (xy 171.464145 84.892405) + (xy 172.704345 86.132605) + (xy 172.712335 86.141385) + (xy 172.716584 86.14808) + (xy 172.722362 86.153506) + (xy 172.722363 86.153507) + (xy 172.768257 86.196604) + (xy 172.771099 86.199359) + (xy 172.791667 86.219927) + (xy 172.79517 86.222644) + (xy 172.804195 86.230352) + (xy 172.837867 86.261972) + (xy 172.844818 86.265793) + (xy 172.844819 86.265794) + (xy 172.856658 86.272303) + (xy 172.873182 86.283157) + (xy 172.883271 86.290982) + (xy 172.890132 86.296304) + (xy 172.897404 86.299451) + (xy 172.897406 86.299452) + (xy 172.932535 86.314654) + (xy 172.943195 86.319876) + (xy 172.968928 86.334023) + (xy 172.983663 86.342124) + (xy 173.004441 86.347459) + (xy 173.023131 86.353858) + (xy 173.042824 86.36238) + (xy 173.086596 86.369313) + (xy 173.088448 86.369606) + (xy 173.100071 86.372013) + (xy 173.128072 86.379202) + (xy 173.144812 86.3835) + (xy 173.166259 86.3835) + (xy 173.185969 86.385051) + (xy 173.207152 86.388406) + (xy 173.253141 86.384059) + (xy 173.264996 86.3835) + (xy 175.756143 86.3835) + (xy 175.824264 86.403502) + (xy 175.870757 86.457158) + (xy 175.875666 86.469622) + (xy 175.883133 86.492003) + (xy 175.883135 86.492008) (xy 175.88545 86.498946) + (xy 175.889299 86.505166) + (xy 175.8893 86.505168) + (xy 175.919756 86.554384) (xy 175.978521 86.649349) (xy 175.983703 86.654522) (xy 176.01613 86.686892) (xy 176.103697 86.774306) - (xy 176.167538 86.813658) + (xy 176.12645 86.788331) (xy 176.222917 86.847794) (xy 176.254261 86.867115) - (xy 176.31572 86.8875) + (xy 176.293968 86.880285) (xy 176.41561 86.920632) (xy 176.415612 86.920632) (xy 176.422138 86.922797) @@ -6159,7 +6038,7 @@ (xy 176.923912 86.9335) (xy 177.3274 86.933499) (xy 177.433167 86.922526) - (xy 177.509081 86.897199) + (xy 177.467953 86.91092) (xy 177.594002 86.868867) (xy 177.594004 86.868866) (xy 177.600946 86.86655) @@ -6169,10 +6048,10 @@ (xy 177.970886 86.657815) (xy 178.015971 86.686733) (xy 178.103697 86.774306) - (xy 178.167538 86.813658) + (xy 178.12645 86.788331) (xy 178.222917 86.847794) (xy 178.254261 86.867115) - (xy 178.31572 86.8875) + (xy 178.293968 86.880285) (xy 178.41561 86.920632) (xy 178.415612 86.920632) (xy 178.422138 86.922797) @@ -6183,7 +6062,7 @@ (xy 178.923912 86.9335) (xy 179.3274 86.933499) (xy 179.433167 86.922526) - (xy 179.509081 86.897199) + (xy 179.467953 86.91092) (xy 179.594002 86.868867) (xy 179.594004 86.868866) (xy 179.600946 86.86655) @@ -6200,10 +6079,10 @@ (xy 183.487703 86.665522) (xy 183.545879 86.723597) (xy 183.607697 86.785306) - (xy 183.655868 86.814999) - (xy 183.746975 86.871158) + (xy 183.613927 86.789146) + (xy 183.740416 86.867115) (xy 183.758261 86.878115) - (xy 183.797479 86.891123) + (xy 183.786556 86.8875) (xy 183.91961 86.931632) (xy 183.919612 86.931632) (xy 183.926138 86.933797) @@ -6214,7 +6093,7 @@ (xy 184.527141 86.9445) (xy 185.0314 86.944499) (xy 185.137167 86.933526) - (xy 185.179052 86.919552) + (xy 185.194383 86.914437) (xy 185.298002 86.879867) (xy 185.298004 86.879866) (xy 185.304946 86.87755) @@ -6226,22 +6105,22 @@ (xy 185.669275 86.514969) (xy 185.669276 86.514967) (xy 185.673115 86.508739) - (xy 185.701924 86.421882) + (xy 185.710116 86.397185) (xy 185.726632 86.34739) (xy 185.726632 86.347388) (xy 185.728797 86.340862) (xy 185.729721 86.331851) - (xy 185.739172 86.239599) + (xy 185.735332 86.27708) (xy 185.7395 86.236401) (xy 185.739499 85.4856) (xy 185.728526 85.379833) - (xy 185.695124 85.279715) + (xy 185.700641 85.296251) (xy 185.674867 85.218998) (xy 185.674866 85.218996) (xy 185.67255 85.212054) (xy 185.579479 85.061651) (xy 185.548889 85.031114) - (xy 185.462454 84.944831) + (xy 185.459484 84.941866) (xy 185.454303 84.936694) (xy 185.450082 84.934092) (xy 185.409583 84.876963) @@ -6250,7 +6129,7 @@ (xy 185.449532 84.738079) (xy 185.455349 84.734479) (xy 185.580306 84.609303) - (xy 185.655413 84.487457) + (xy 185.654553 84.488852) (xy 185.669275 84.464969) (xy 185.669276 84.464967) (xy 185.673115 84.458739) @@ -6261,7 +6140,7 @@ (xy 185.7395 84.186401) (xy 185.739499 83.4356) (xy 185.728526 83.329833) - (xy 185.693599 83.225144) + (xy 185.707762 83.267595) (xy 185.674867 83.168998) (xy 185.674866 83.168996) (xy 185.67255 83.162054) @@ -6287,14 +6166,38 @@ (xy 183.606651 82.887521) (xy 183.481694 83.012697) (xy 183.451822 83.061159) - (xy 183.417021 83.117616) - (xy 183.364249 83.165109) - (xy 183.309761 83.1775) - (xy 173.545976 83.1775) - (xy 173.477855 83.157498) - (xy 173.462276 83.145602) + (xy 183.393893 83.155137) + (xy 183.388885 83.163261) + (xy 183.333203 83.331138) + (xy 183.332503 83.337974) + (xy 183.332502 83.337977) + (xy 183.3312 83.350688) + (xy 183.3225 83.435599) + (xy 183.322501 83.688335) + (xy 183.322501 83.8225) + (xy 183.302499 83.89062) + (xy 183.248844 83.937113) + (xy 183.196501 83.9485) + (xy 173.923594 83.9485) + (xy 173.855473 83.928498) + (xy 173.834499 83.911595) + (xy 173.794122 83.871218) + (xy 173.760096 83.808906) + (xy 173.757907 83.795293) + (xy 173.757004 83.786695) + (xy 173.744037 83.663327) + (xy 173.741232 83.636635) + (xy 173.741232 83.636633) + (xy 173.740542 83.630072) + (xy 173.681527 83.448444) + (xy 173.674112 83.4356) + (xy 173.613047 83.329833) + (xy 173.58604 83.283056) + (xy 173.562722 83.257158) + (xy 173.462675 83.146045) + (xy 173.462674 83.146044) (xy 173.458253 83.141134) - (xy 173.451873 83.136498) + (xy 173.335311 83.051811) (xy 173.309094 83.032763) (xy 173.309093 83.032762) (xy 173.303752 83.028882) @@ -6307,11 +6210,60 @@ (xy 172.948944 82.912872) (xy 172.948939 82.912872) (xy 172.942487 82.9115) - (xy 172.886594 82.9115) - (xy 172.818473 82.891498) - (xy 172.797499 82.874595) - (xy 171.174756 81.251851) - (xy 171.001574 81.078669) + (xy 172.886595 82.9115) + (xy 172.818474 82.891498) + (xy 172.7975 82.874595) + (xy 172.080652 82.157747) + (xy 172.073112 82.149461) + (xy 172.069 82.142982) + (xy 172.019348 82.096356) + (xy 172.016507 82.093602) + (xy 171.99677 82.073865) + (xy 171.993573 82.071385) + (xy 171.984551 82.06368) + (xy 171.952321 82.033414) + (xy 171.945375 82.029595) + (xy 171.945372 82.029593) + (xy 171.934566 82.023652) + (xy 171.918047 82.012801) + (xy 171.917583 82.012441) + (xy 171.902041 82.000386) + (xy 171.894772 81.997241) + (xy 171.894768 81.997238) + (xy 171.861463 81.982826) + (xy 171.850813 81.977609) + (xy 171.81206 81.956305) + (xy 171.792437 81.951267) + (xy 171.773734 81.944863) + (xy 171.76242 81.939967) + (xy 171.762419 81.939967) + (xy 171.755145 81.936819) + (xy 171.747322 81.93558) + (xy 171.747312 81.935577) + (xy 171.711476 81.929901) + (xy 171.699856 81.927495) + (xy 171.664711 81.918472) + (xy 171.66471 81.918472) + (xy 171.65703 81.9165) + (xy 171.636776 81.9165) + (xy 171.617065 81.914949) + (xy 171.608681 81.913621) + (xy 171.597057 81.91178) + (xy 171.567786 81.914547) + (xy 171.553039 81.915941) + (xy 171.541181 81.9165) + (xy 169.036477 81.9165) + (xy 168.968356 81.896498) + (xy 168.921863 81.842842) + (xy 168.911759 81.772568) + (xy 168.915917 81.753879) + (xy 168.97237 81.568069) + (xy 169.001529 81.34659) + (xy 169.00289 81.290897) + (xy 169.003074 81.283365) + (xy 169.003074 81.283361) + (xy 169.003156 81.28) + (xy 168.986604 81.078669) (xy 174.867001 81.078669) (xy 174.867371 81.08549) (xy 174.872895 81.136352) @@ -6426,51 +6378,40 @@ (xy 174.868672 80.768865) (xy 174.867001 80.776548) (xy 174.867001 81.078669) - (xy 171.001574 81.078669) - (xy 169.540652 79.617747) - (xy 169.533112 79.609461) - (xy 169.529 79.602982) - (xy 169.479348 79.556356) - (xy 169.476507 79.553602) - (xy 169.45677 79.533865) - (xy 169.453573 79.531385) - (xy 169.444551 79.52368) - (xy 169.412321 79.493414) - (xy 169.405375 79.489595) - (xy 169.405372 79.489593) - (xy 169.394566 79.483652) - (xy 169.378047 79.472801) - (xy 169.377583 79.472441) - (xy 169.362041 79.460386) - (xy 169.354772 79.457241) - (xy 169.354768 79.457238) - (xy 169.321463 79.442826) - (xy 169.310813 79.437609) - (xy 169.27206 79.416305) - (xy 169.252437 79.411267) - (xy 169.233734 79.404863) - (xy 169.22242 79.399967) - (xy 169.222419 79.399967) - (xy 169.215145 79.396819) - (xy 169.207322 79.39558) - (xy 169.207312 79.395577) - (xy 169.171476 79.389901) - (xy 169.159856 79.387495) - (xy 169.124711 79.378472) - (xy 169.12471 79.378472) - (xy 169.11703 79.3765) - (xy 169.096776 79.3765) - (xy 169.077065 79.374949) - (xy 169.074534 79.374548) - (xy 169.057057 79.37178) - (xy 169.049165 79.372526) - (xy 169.041242 79.372277) - (xy 169.041284 79.370937) - (xy 168.979681 79.359005) - (xy 168.928344 79.309964) - (xy 168.911669 79.240953) - (xy 168.916962 79.210437) - (xy 168.91845 79.205539) + (xy 168.986604 81.078669) + (xy 168.984852 81.057361) + (xy 168.930431 80.840702) + (xy 168.841354 80.63584) + (xy 168.780079 80.541123) + (xy 168.722822 80.452617) + (xy 168.72282 80.452614) + (xy 168.720014 80.448277) + (xy 168.56967 80.283051) + (xy 168.565619 80.279852) + (xy 168.565615 80.279848) + (xy 168.398414 80.1478) + (xy 168.39841 80.147798) + (xy 168.394359 80.144598) + (xy 168.353053 80.121796) + (xy 168.303084 80.071364) + (xy 168.288312 80.001921) + (xy 168.313428 79.935516) + (xy 168.34078 79.908909) + (xy 168.400384 79.866394) + (xy 168.51986 79.781173) + (xy 168.540313 79.760792) + (xy 168.625552 79.67585) + (xy 168.678096 79.623489) + (xy 168.737594 79.540689) + (xy 168.805435 79.446277) + (xy 168.808453 79.442077) + (xy 168.813001 79.432876) + (xy 168.905136 79.246453) + (xy 168.905137 79.246451) + (xy 168.90743 79.241811) + (xy 168.95146 79.096891) + (xy 168.970865 79.033023) + (xy 168.970865 79.033021) (xy 168.97237 79.028069) (xy 169.001529 78.80659) (xy 169.002081 78.784) @@ -6495,7 +6436,7 @@ (xy 168.288312 77.461921) (xy 168.313428 77.395516) (xy 168.34078 77.368909) - (xy 168.384603 77.33765) + (xy 168.422888 77.310342) (xy 168.51986 77.241173) (xy 168.678096 77.083489) (xy 168.701164 77.051387) @@ -6510,73 +6451,197 @@ (xy 168.970865 76.493021) (xy 168.97237 76.488069) (xy 169.001529 76.26659) - (xy 169.001754 76.257401) - (xy 169.002676 76.219654) - (xy 169.024336 76.152042) - (xy 169.079111 76.106874) - (xy 169.149611 76.09849) - (xy 169.217733 76.133637) - (xy 172.978343 79.894247) - (xy 172.985887 79.902537) - (xy 172.99 79.909018) - (xy 172.995777 79.914443) - (xy 173.039667 79.955658) - (xy 173.042509 79.958413) - (xy 173.062231 79.978135) - (xy 173.065355 79.980558) - (xy 173.065359 79.980562) - (xy 173.065424 79.980612) - (xy 173.074445 79.988317) - (xy 173.106679 80.018586) - (xy 173.113627 80.022405) - (xy 173.113629 80.022407) - (xy 173.124432 80.028346) - (xy 173.140959 80.039202) - (xy 173.150698 80.046757) - (xy 173.1507 80.046758) - (xy 173.15696 80.051614) - (xy 173.19754 80.069174) - (xy 173.208188 80.074391) - (xy 173.232976 80.088018) - (xy 173.24694 80.095695) - (xy 173.254616 80.097666) - (xy 173.254619 80.097667) - (xy 173.266562 80.100733) - (xy 173.285267 80.107137) - (xy 173.303855 80.115181) - (xy 173.311678 80.11642) - (xy 173.311688 80.116423) - (xy 173.347524 80.122099) - (xy 173.359144 80.124505) - (xy 173.390959 80.132673) - (xy 173.40197 80.1355) - (xy 173.422224 80.1355) - (xy 173.441934 80.137051) - (xy 173.461943 80.14022) - (xy 173.469835 80.139474) - (xy 173.505961 80.136059) - (xy 173.517819 80.1355) - (xy 174.742909 80.1355) - (xy 174.81103 80.155502) - (xy 174.857523 80.209158) - (xy 174.863805 80.226003) + (xy 169.001642 76.261991) + (xy 169.002435 76.229516) + (xy 169.002785 76.215179) + (xy 169.024444 76.147567) + (xy 169.07922 76.102398) + (xy 169.149719 76.094014) + (xy 169.202808 76.11632) + (xy 169.207389 76.119648) + (xy 169.213168 76.125075) + (xy 169.220113 76.128893) + (xy 169.220116 76.128895) + (xy 169.230921 76.134835) + (xy 169.247448 76.145691) + (xy 169.257187 76.153246) + (xy 169.257189 76.153247) + (xy 169.263449 76.158103) + (xy 169.304029 76.175663) + (xy 169.314677 76.18088) + (xy 169.353429 76.202184) + (xy 169.361105 76.204155) + (xy 169.361108 76.204156) + (xy 169.373051 76.207222) + (xy 169.391756 76.213626) + (xy 169.410344 76.22167) + (xy 169.418167 76.222909) + (xy 169.418177 76.222912) + (xy 169.454013 76.228588) + (xy 169.465633 76.230994) + (xy 169.500778 76.240017) + (xy 169.508459 76.241989) + (xy 169.528713 76.241989) + (xy 169.548423 76.24354) + (xy 169.568432 76.246709) + (xy 169.576324 76.245963) + (xy 169.61245 76.242548) + (xy 169.624308 76.241989) + (xy 173.8205 76.241989) + (xy 173.888621 76.261991) + (xy 173.935114 76.315647) + (xy 173.9465 76.367989) + (xy 173.9465 78.891134) + (xy 173.953255 78.953316) + (xy 174.004385 79.089705) + (xy 174.091739 79.206261) + (xy 174.208295 79.293615) + (xy 174.344684 79.344745) + (xy 174.406866 79.3515) + (xy 174.993599 79.3515) + (xy 175.06172 79.371502) + (xy 175.108213 79.425158) + (xy 175.118317 79.495432) + (xy 175.088823 79.560012) + (xy 175.069164 79.578326) + (xy 175.019276 79.615715) + (xy 175.006715 79.628276) + (xy 174.930214 79.730351) + (xy 174.921676 79.745946) + (xy 174.876522 79.866394) + (xy 174.872895 79.881649) + (xy 174.867369 79.932514) + (xy 174.867 79.939328) + (xy 174.867 80.236885) (xy 174.871475 80.252124) (xy 174.872865 80.253329) (xy 174.880548 80.255) + (xy 175.702885 80.255) + (xy 175.718124 80.250525) + (xy 175.719329 80.249135) + (xy 175.721 80.241452) + (xy 175.721 80.236885) + (xy 176.229 80.236885) + (xy 176.233475 80.252124) + (xy 176.234865 80.253329) + (xy 176.242548 80.255) (xy 177.064884 80.255) (xy 177.080123 80.250525) (xy 177.081328 80.249135) - (xy 177.084464 80.234718) - (xy 177.118489 80.172405) - (xy 177.180801 80.13838) - (xy 177.207585 80.1355) - (xy 177.332909 80.1355) - (xy 177.40103 80.155502) - (xy 177.447523 80.209158) - (xy 177.453805 80.226003) + (xy 177.082999 80.241452) + (xy 177.082999 80.236885) + (xy 177.457 80.236885) (xy 177.461475 80.252124) (xy 177.462865 80.253329) (xy 177.470548 80.255) + (xy 178.887885 80.255) + (xy 178.903124 80.250525) + (xy 178.904329 80.249135) + (xy 178.906 80.241452) + (xy 178.906 79.494116) + (xy 178.901525 79.478877) + (xy 178.900135 79.477672) + (xy 178.892452 79.476001) + (xy 177.920331 79.476001) + (xy 177.91351 79.476371) + (xy 177.862648 79.481895) + (xy 177.847396 79.485521) + (xy 177.726946 79.530676) + (xy 177.711351 79.539214) + (xy 177.609276 79.615715) + (xy 177.596715 79.628276) + (xy 177.520214 79.730351) + (xy 177.511676 79.745946) + (xy 177.466522 79.866394) + (xy 177.462895 79.881649) + (xy 177.457369 79.932514) + (xy 177.457 79.939328) + (xy 177.457 80.236885) + (xy 177.082999 80.236885) + (xy 177.082999 79.939331) + (xy 177.082629 79.93251) + (xy 177.077105 79.881648) + (xy 177.073479 79.866396) + (xy 177.028324 79.745946) + (xy 177.019786 79.730351) + (xy 176.943285 79.628276) + (xy 176.930724 79.615715) + (xy 176.828649 79.539214) + (xy 176.813054 79.530676) + (xy 176.692606 79.485522) + (xy 176.677351 79.481895) + (xy 176.626486 79.476369) + (xy 176.619672 79.476) + (xy 176.247115 79.476) + (xy 176.231876 79.480475) + (xy 176.230671 79.481865) + (xy 176.229 79.489548) + (xy 176.229 80.236885) + (xy 175.721 80.236885) + (xy 175.721 79.494116) + (xy 175.716525 79.478877) + (xy 175.715135 79.477672) + (xy 175.707452 79.476001) + (xy 175.386566 79.476001) + (xy 175.318445 79.455999) + (xy 175.271952 79.402343) + (xy 175.261848 79.332069) + (xy 175.291342 79.267489) + (xy 175.311001 79.249175) + (xy 175.361081 79.211642) + (xy 175.368261 79.206261) + (xy 175.455615 79.089705) + (xy 175.506745 78.953316) + (xy 175.5135 78.891134) + (xy 175.5135 76.367989) + (xy 175.533502 76.299868) + (xy 175.587158 76.253375) + (xy 175.6395 76.241989) + (xy 178.669895 76.241989) + (xy 178.738016 76.261991) + (xy 178.75899 76.278894) + (xy 180.919595 78.439499) + (xy 180.953621 78.501811) + (xy 180.956149 78.525329) + (xy 180.956316 78.52532) + (xy 180.956487 78.528469) + (xy 180.9565 78.528594) + (xy 180.9565 78.532134) + (xy 180.963255 78.594316) + (xy 180.966029 78.601715) + (xy 181.00346 78.701562) + (xy 181.014385 78.730705) + (xy 181.013534 78.731024) + (xy 181.027055 78.792849) + (xy 181.014042 78.837166) + (xy 181.014385 78.837295) + (xy 181.011236 78.845696) + (xy 181.011234 78.845699) + (xy 180.992928 78.894531) + (xy 180.963255 78.973684) + (xy 180.9565 79.035866) + (xy 180.9565 79.561236) + (xy 180.936498 79.629357) + (xy 180.882842 79.67585) + (xy 180.812568 79.685954) + (xy 180.747988 79.65646) + (xy 180.729673 79.6368) + (xy 180.723284 79.628275) + (xy 180.710724 79.615715) + (xy 180.608649 79.539214) + (xy 180.593054 79.530676) + (xy 180.472606 79.485522) + (xy 180.457351 79.481895) + (xy 180.406486 79.476369) + (xy 180.399672 79.476) + (xy 179.432115 79.476) + (xy 179.416876 79.480475) + (xy 179.415671 79.481865) + (xy 179.414 79.489548) + (xy 179.414 80.236885) + (xy 179.418475 80.252124) + (xy 179.419865 80.253329) + (xy 179.427548 80.255) (xy 180.844884 80.255) (xy 180.860123 80.250525) (xy 180.861328 80.249135) @@ -6600,7 +6665,7 @@ (xy 182.9735 79.632134) (xy 182.9735 79.035866) (xy 182.966745 78.973684) - (xy 182.939426 78.900811) + (xy 182.937072 78.894531) (xy 182.918766 78.845699) (xy 182.918764 78.845696) (xy 182.915615 78.837295) @@ -6616,9 +6681,6 @@ (xy 182.9735 78.532134) (xy 182.9735 77.935866) (xy 182.966745 77.873684) - (xy 182.927324 77.768528) - (xy 182.918766 77.745699) - (xy 182.918764 77.745696) (xy 182.915615 77.737295) (xy 182.916307 77.737036) (xy 182.902657 77.674626) @@ -6635,109 +6697,14 @@ (xy 182.968525 77.386876) (xy 182.967135 77.385671) (xy 182.959452 77.384) - (xy 180.975116 77.384) - (xy 180.959877 77.388475) - (xy 180.958672 77.389865) - (xy 180.957001 77.397548) - (xy 180.957001 77.428669) - (xy 180.957371 77.43549) - (xy 180.960127 77.460869) - (xy 180.947598 77.530751) - (xy 180.899276 77.582766) - (xy 180.838852 77.600411) - (xy 180.838031 77.600437) - (xy 180.834043 77.6005) - (xy 180.806144 77.6005) - (xy 180.802154 77.601004) - (xy 180.79032 77.601936) - (xy 180.746111 77.603326) - (xy 180.738497 77.605538) - (xy 180.738492 77.605539) - (xy 180.726659 77.608977) - (xy 180.707296 77.612988) - (xy 180.687203 77.615526) - (xy 180.679836 77.618443) - (xy 180.679831 77.618444) - (xy 180.646092 77.631802) - (xy 180.634865 77.635646) - (xy 180.592407 77.647982) - (xy 180.585581 77.652019) - (xy 180.574972 77.658293) - (xy 180.557224 77.666988) - (xy 180.538383 77.674448) - (xy 180.531967 77.67911) - (xy 180.531966 77.67911) - (xy 180.502613 77.700436) - (xy 180.492693 77.706952) - (xy 180.461465 77.72542) - (xy 180.461462 77.725422) - (xy 180.454638 77.729458) - (xy 180.440317 77.743779) - (xy 180.425284 77.756619) - (xy 180.408893 77.768528) - (xy 180.403842 77.774634) - (xy 180.380702 77.802605) - (xy 180.372712 77.811384) - (xy 179.3525 78.831595) - (xy 179.290188 78.865621) - (xy 179.263405 78.8685) - (xy 175.6395 78.8685) - (xy 175.571379 78.848498) - (xy 175.524886 78.794842) - (xy 175.5135 78.7425) - (xy 175.5135 76.3245) - (xy 175.533502 76.256379) - (xy 175.587158 76.209886) - (xy 175.6395 76.1985) - (xy 179.390406 76.1985) - (xy 179.458527 76.218502) - (xy 179.479501 76.235405) - (xy 179.836343 76.592247) - (xy 179.843887 76.600537) - (xy 179.848 76.607018) - (xy 179.853777 76.612443) - (xy 179.897667 76.653658) - (xy 179.900509 76.656413) - (xy 179.920231 76.676135) - (xy 179.923355 76.678558) - (xy 179.923359 76.678562) - (xy 179.923424 76.678612) - (xy 179.932445 76.686317) - (xy 179.964679 76.716586) - (xy 179.971627 76.720405) - (xy 179.971629 76.720407) - (xy 179.982432 76.726346) - (xy 179.998959 76.737202) - (xy 180.008698 76.744757) - (xy 180.0087 76.744758) - (xy 180.01496 76.749614) - (xy 180.05554 76.767174) - (xy 180.066188 76.772391) - (xy 180.083027 76.781648) - (xy 180.10494 76.793695) - (xy 180.112616 76.795666) - (xy 180.112619 76.795667) - (xy 180.124562 76.798733) - (xy 180.143267 76.805137) - (xy 180.161855 76.813181) - (xy 180.169678 76.81442) - (xy 180.169688 76.814423) - (xy 180.205524 76.820099) - (xy 180.217144 76.822505) - (xy 180.248959 76.830673) - (xy 180.25997 76.8335) - (xy 180.280224 76.8335) - (xy 180.299934 76.835051) - (xy 180.319943 76.83822) - (xy 180.327835 76.837474) - (xy 180.353467 76.835051) - (xy 180.363962 76.834059) - (xy 180.375819 76.8335) - (xy 180.859518 76.8335) - (xy 180.927639 76.853502) - (xy 180.94203 76.864276) - (xy 180.962864 76.882328) - (xy 180.970548 76.884) + (xy 181.841 77.384) + (xy 181.772879 77.363998) + (xy 181.726386 77.310342) + (xy 181.715 77.258) + (xy 181.715 77.01) + (xy 181.735002 76.941879) + (xy 181.788658 76.895386) + (xy 181.841 76.884) (xy 182.954884 76.884) (xy 182.970123 76.879525) (xy 182.971328 76.878135) @@ -6786,7 +6753,7 @@ (xy 182.915615 74.330705) (xy 182.917372 74.326019) (xy 182.917373 74.326015) - (xy 182.921287 74.315577) + (xy 182.920049 74.318879) (xy 182.963971 74.201715) (xy 182.966745 74.194316) (xy 182.9735 74.132134) @@ -6802,7 +6769,7 @@ (xy 182.915615 73.230705) (xy 182.917372 73.226019) (xy 182.917373 73.226015) - (xy 182.919443 73.220496) + (xy 182.927505 73.19899) (xy 182.963971 73.101715) (xy 182.966745 73.094316) (xy 182.972815 73.03844) @@ -6817,8 +6784,8 @@ (xy 182.915615 72.130705) (xy 182.917372 72.126019) (xy 182.917373 72.126015) - (xy 182.926202 72.102466) - (xy 182.961221 72.009051) + (xy 182.926939 72.1005) + (xy 182.961682 72.007821) (xy 182.966745 71.994316) (xy 182.9735 71.932134) (xy 182.9735 71.335866) @@ -6831,46 +6798,151 @@ (xy 181.416866 70.8755) (xy 181.354684 70.882255) (xy 181.218295 70.933385) - (xy 181.152165 70.982947) - (xy 181.136512 70.994678) - (xy 181.070006 71.019526) - (xy 181.000623 71.004473) - (xy 180.971852 70.982947) - (xy 180.335652 70.346747) - (xy 180.328112 70.338461) - (xy 180.324 70.331982) - (xy 180.303744 70.31296) - (xy 180.274349 70.285357) - (xy 180.271507 70.282602) - (xy 180.25177 70.262865) - (xy 180.248573 70.260385) - (xy 180.239551 70.25268) - (xy 180.238705 70.251885) - (xy 180.222747 70.2369) - (xy 180.186782 70.175687) - (xy 180.183227 70.146888) + (xy 181.101739 71.020739) + (xy 181.014385 71.137295) + (xy 180.963255 71.273684) + (xy 180.9565 71.335866) + (xy 180.9565 71.932134) + (xy 180.956869 71.935529) + (xy 180.956869 71.935533) + (xy 180.959624 71.960893) + (xy 180.947096 72.030775) + (xy 180.898775 72.082791) + (xy 180.834361 72.1005) + (xy 177.569594 72.1005) + (xy 177.501473 72.080498) + (xy 177.480499 72.063595) + (xy 176.354006 70.937101) + (xy 176.31998 70.874789) + (xy 176.325045 70.803973) + (xy 176.356994 70.761255) + (xy 176.354374 70.758635) + (xy 176.373285 70.739724) + (xy 176.449786 70.637649) + (xy 176.458324 70.622054) + (xy 176.503478 70.501606) + (xy 176.507105 70.486351) + (xy 176.512631 70.435486) + (xy 176.513 70.428672) + (xy 176.513 70.428669) + (xy 176.967001 70.428669) + (xy 176.967371 70.43549) + (xy 176.972895 70.486352) + (xy 176.976521 70.501604) + (xy 177.021676 70.622054) + (xy 177.030214 70.637649) + (xy 177.106715 70.739724) + (xy 177.119276 70.752285) + (xy 177.221351 70.828786) + (xy 177.236946 70.837324) + (xy 177.357394 70.882478) + (xy 177.372649 70.886105) + (xy 177.423514 70.891631) + (xy 177.430328 70.892) + (xy 177.742885 70.892) + (xy 177.758124 70.887525) + (xy 177.759329 70.886135) + (xy 177.761 70.878452) + (xy 177.761 70.873884) + (xy 178.269 70.873884) + (xy 178.273475 70.889123) + (xy 178.274865 70.890328) + (xy 178.282548 70.891999) + (xy 178.599669 70.891999) + (xy 178.60649 70.891629) + (xy 178.657352 70.886105) + (xy 178.672604 70.882479) + (xy 178.793054 70.837324) + (xy 178.808644 70.828789) + (xy 178.890858 70.767173) + (xy 178.957365 70.742326) + (xy 178.966423 70.742) + (xy 179.012885 70.742) + (xy 179.028124 70.737525) + (xy 179.029329 70.736135) + (xy 179.031 70.728452) + (xy 179.031 70.723884) + (xy 179.539 70.723884) + (xy 179.543475 70.739123) + (xy 179.544865 70.740328) + (xy 179.552548 70.741999) + (xy 179.719669 70.741999) + (xy 179.72649 70.741629) + (xy 179.777352 70.736105) + (xy 179.792604 70.732479) + (xy 179.913054 70.687324) + (xy 179.928649 70.678786) + (xy 180.030724 70.602285) + (xy 180.043285 70.589724) + (xy 180.119786 70.487649) + (xy 180.128324 70.472054) + (xy 180.173478 70.351606) + (xy 180.177105 70.336351) + (xy 180.182631 70.285486) + (xy 180.183 70.278672) + (xy 180.183 70.146115) (xy 180.178525 70.130876) (xy 180.177135 70.129671) (xy 180.169452 70.128) - (xy 180.032025 70.128) - (xy 180.010288 70.124906) - (xy 180.010144 70.125818) - (xy 179.966476 70.118901) - (xy 179.954856 70.116495) - (xy 179.919711 70.107472) - (xy 179.91971 70.107472) - (xy 179.91203 70.1055) - (xy 179.891776 70.1055) - (xy 179.872065 70.103949) - (xy 179.859886 70.10202) - (xy 179.852057 70.10078) - (xy 179.814048 70.104373) - (xy 179.808039 70.104941) - (xy 179.796181 70.1055) - (xy 175.277 70.1055) - (xy 175.208879 70.085498) - (xy 175.162386 70.031842) - (xy 175.151 69.9795) + (xy 179.557115 70.128) + (xy 179.541876 70.132475) + (xy 179.540671 70.133865) + (xy 179.539 70.141548) + (xy 179.539 70.723884) + (xy 179.031 70.723884) + (xy 179.031 70.146115) + (xy 179.026525 70.130876) + (xy 179.025135 70.129671) + (xy 179.017452 70.128) + (xy 178.403513 70.128) + (xy 178.37309 70.119067) + (xy 178.372559 70.121507) + (xy 178.333452 70.113) + (xy 178.287115 70.113) + (xy 178.271876 70.117475) + (xy 178.270671 70.118865) + (xy 178.269 70.126548) + (xy 178.269 70.873884) + (xy 177.761 70.873884) + (xy 177.761 70.131115) + (xy 177.756525 70.115876) + (xy 177.755135 70.114671) + (xy 177.747452 70.113) + (xy 176.985116 70.113) + (xy 176.969877 70.117475) + (xy 176.968672 70.118865) + (xy 176.967001 70.126548) + (xy 176.967001 70.428669) + (xy 176.513 70.428669) + (xy 176.513 70.131115) + (xy 176.508525 70.115876) + (xy 176.507135 70.114671) + (xy 176.499452 70.113) + (xy 175.385159 70.113) + (xy 175.353826 70.109042) + (xy 175.347711 70.107472) + (xy 175.34771 70.107472) + (xy 175.34003 70.1055) + (xy 175.319776 70.1055) + (xy 175.300065 70.103949) + (xy 175.287886 70.10202) + (xy 175.280057 70.10078) + (xy 175.242048 70.104373) + (xy 175.236039 70.104941) + (xy 175.224181 70.1055) + (xy 169.859595 70.1055) + (xy 169.791474 70.085498) + (xy 169.770499 70.068595) + (xy 169.477421 69.775516) + (xy 169.28879 69.586885) + (xy 174.297 69.586885) + (xy 174.301475 69.602124) + (xy 174.302865 69.603329) + (xy 174.310548 69.605) + (xy 175.132885 69.605) + (xy 175.148124 69.600525) + (xy 175.149329 69.599135) + (xy 175.151 69.591452) (xy 175.151 69.586885) (xy 175.659 69.586885) (xy 175.663475 69.602124) @@ -7004,45 +7076,11 @@ (xy 174.306522 69.216394) (xy 174.302895 69.231649) (xy 174.297369 69.282514) - (xy 174.297 69.289327) - (xy 174.297001 69.730437) - (xy 174.276999 69.798558) - (xy 174.223344 69.845051) - (xy 174.15307 69.855155) - (xy 174.1103 69.840851) - (xy 174.093569 69.831653) - (xy 174.077047 69.820801) - (xy 174.071753 69.816695) - (xy 174.061041 69.808386) - (xy 174.053772 69.805241) - (xy 174.053768 69.805238) - (xy 174.020463 69.790826) - (xy 174.009813 69.785609) - (xy 173.97106 69.764305) - (xy 173.951437 69.759267) - (xy 173.932734 69.752863) - (xy 173.92142 69.747967) - (xy 173.921419 69.747967) - (xy 173.914145 69.744819) - (xy 173.906322 69.74358) - (xy 173.906312 69.743577) - (xy 173.870476 69.737901) - (xy 173.858856 69.735495) - (xy 173.823711 69.726472) - (xy 173.82371 69.726472) - (xy 173.81603 69.7245) - (xy 173.795776 69.7245) - (xy 173.776065 69.722949) - (xy 173.770074 69.722) - (xy 173.756057 69.71978) - (xy 173.748165 69.720526) - (xy 173.712039 69.723941) - (xy 173.700181 69.7245) - (xy 169.478595 69.7245) - (xy 169.410474 69.704498) - (xy 169.3895 69.687595) - (xy 169.159652 69.457747) - (xy 169.152112 69.449461) + (xy 174.297 69.289328) + (xy 174.297 69.586885) + (xy 169.28879 69.586885) + (xy 169.159647 69.457742) + (xy 169.152113 69.449463) (xy 169.148 69.442982) (xy 169.098348 69.396356) (xy 169.095507 69.393602) @@ -7129,8 +7167,8 @@ (xy 170.080377 67.216852) (xy 170.143335 67.286774) (xy 170.203745 67.353866) - (xy 170.295142 67.42027) - (xy 170.339818 67.452729) + (xy 170.302841 67.425864) + (xy 170.345914 67.457158) (xy 170.358246 67.466118) (xy 170.364274 67.468802) (xy 170.364276 67.468803) @@ -7149,16 +7187,15 @@ (xy 171.26572 67.468803) (xy 171.265722 67.468802) (xy 171.27175 67.466118) - (xy 171.290179 67.452729) - (xy 171.38944 67.380611) - (xy 171.41428 67.362564) - (xy 171.481146 67.338706) - (xy 171.48834 67.3385) - (xy 172.717754 67.3385) - (xy 172.785875 67.358502) - (xy 172.832368 67.412158) - (xy 172.835736 67.42027) - (xy 172.865519 67.499715) + (xy 171.284083 67.457158) + (xy 171.352342 67.407564) + (xy 171.419209 67.383706) + (xy 171.426403 67.3835) + (xy 172.734624 67.3835) + (xy 172.802745 67.403502) + (xy 172.849238 67.457158) + (xy 172.852606 67.46527) + (xy 172.863582 67.494547) (xy 172.882385 67.544705) (xy 172.969739 67.661261) (xy 173.086295 67.748615) @@ -7346,9 +7383,6 @@ (xy 185.09414 62.67864) (xy 185.094138 62.678635) (xy 185.091937 62.672654) - (xy 185.013407 62.545999) - (xy 184.992688 62.512582) - (xy 184.992687 62.512581) (xy 184.989326 62.50716) (xy 184.961307 62.47753) (xy 184.859919 62.370315) @@ -7381,8 +7415,11 @@ (xy 183.67615 62.30387) (xy 183.671309 62.308019) (xy 183.671305 62.308022) - (xy 183.544152 62.417006) + (xy 183.562983 62.400866) (xy 183.528302 62.430591) + (xy 183.524391 62.435633) + (xy 183.52439 62.435634) + (xy 183.491892 62.47753) (xy 183.408954 62.584453) (xy 183.406138 62.590176) (xy 183.406136 62.590179) @@ -7498,15 +7535,13 @@ (xy 172.882385 65.551295) (xy 172.831255 65.687684) (xy 172.8245 65.749866) - (xy 172.8245 65.8855) - (xy 172.804498 65.953621) - (xy 172.750842 66.000114) - (xy 172.6985 66.0115) - (xy 171.48834 66.0115) - (xy 171.420219 65.991498) - (xy 171.414279 65.987436) - (xy 171.400026 65.97708) - (xy 171.281707 65.891116) + (xy 172.8245 65.8405) + (xy 172.804498 65.908621) + (xy 172.750842 65.955114) + (xy 172.6985 65.9665) + (xy 171.426403 65.9665) + (xy 171.358282 65.946498) + (xy 171.352342 65.942436) (xy 171.277092 65.887763) (xy 171.277091 65.887762) (xy 171.27175 65.883882) @@ -7651,11 +7686,11 @@ (xy 184.125293 61.053165) (xy 184.131685 61.0535) (xy 184.274663 61.0535) - (xy 184.376715 61.043134) + (xy 184.347653 61.046086) (xy 184.413378 61.03941) (xy 184.413379 61.03941) (xy 184.419727 61.038765) - (xy 184.476106 61.021097) + (xy 184.500843 61.013345) (xy 184.599451 60.982444) (xy 184.599456 60.982442) (xy 184.605541 60.980535) @@ -7694,10 +7729,10 @@ (xy 184.920682 59.43457) (xy 184.859919 59.370315) (xy 184.855534 59.365678) - (xy 184.843858 59.357502) + (xy 184.813387 59.336166) (xy 184.701259 59.257654) (xy 184.696025 59.253989) - (xy 184.638256 59.22899) + (xy 184.631531 59.22608) (xy 184.523175 59.17919) (xy 184.523171 59.179189) (xy 184.517316 59.176655) @@ -7708,7 +7743,7 @@ (xy 184.326707 59.136835) (xy 184.320315 59.1365) (xy 184.177337 59.1365) - (xy 184.142644 59.140024) + (xy 184.136816 59.140616) (xy 184.038622 59.15059) (xy 184.038621 59.15059) (xy 184.032273 59.151235) @@ -7849,16 +7884,14 @@ (xy 172.969739 60.608739) (xy 172.882385 60.725295) (xy 172.831255 60.861684) - (xy 172.8245 60.923866) - (xy 172.8245 60.9325) - (xy 172.804498 61.000621) - (xy 172.750842 61.047114) - (xy 172.6985 61.0585) - (xy 171.488342 61.0585) - (xy 171.420221 61.038498) - (xy 171.414281 61.034436) - (xy 171.381367 61.010522) - (xy 171.311829 60.96) + (xy 172.828695 60.885248) + (xy 172.826972 60.901108) + (xy 172.79973 60.96667) + (xy 172.741366 61.007096) + (xy 172.701709 61.0135) + (xy 171.426405 61.0135) + (xy 171.358284 60.993498) + (xy 171.352344 60.989436) (xy 171.277094 60.934763) (xy 171.277093 60.934762) (xy 171.271752 60.930882) @@ -7867,81 +7900,81 @@ (xy 171.103319 60.855891) (xy 171.103318 60.855891) (xy 171.097288 60.853206) - (xy 171.003887 60.833353) - (xy 170.916944 60.814872) - (xy 170.916939 60.814872) - (xy 170.910487 60.8135) - (xy 170.897021 60.8135) - (xy 170.8289 60.793498) - (xy 170.807926 60.776595) - (xy 169.25251 59.221179) - (xy 169.246656 59.214913) - (xy 169.246387 59.214604) - (xy 169.21123 59.174303) - (xy 169.162444 59.140016) - (xy 169.15716 59.136091) - (xy 169.116212 59.103984) - (xy 169.110237 59.099299) - (xy 169.103318 59.096175) - (xy 169.097372 59.092574) - (xy 169.092215 59.089633) - (xy 169.086057 59.086331) - (xy 169.079841 59.081962) - (xy 169.072765 59.079203) - (xy 169.072763 59.079202) - (xy 169.024305 59.060309) - (xy 169.018235 59.057758) - (xy 168.98536 59.042914) - (xy 168.931507 58.996652) - (xy 168.911214 58.928617) - (xy 168.916654 58.89145) - (xy 168.918174 58.886449) + (xy 170.997105 60.831911) + (xy 170.944432 60.820715) + (xy 170.881534 60.786563) + (xy 169.285443 59.190473) + (xy 169.279589 59.184207) + (xy 169.246557 59.146341) + (xy 169.246554 59.146338) + (xy 169.241562 59.140616) + (xy 169.189281 59.103872) + (xy 169.183987 59.09994) + (xy 169.139694 59.06521) + (xy 169.133719 59.060525) + (xy 169.126803 59.057402) + (xy 169.124517 59.056018) + (xy 169.109836 59.047644) + (xy 169.107476 59.046379) + (xy 169.101262 59.042011) + (xy 169.094183 59.039251) + (xy 169.094181 59.03925) + (xy 169.041726 59.018799) + (xy 169.035652 59.016246) + (xy 169.013001 59.006018) + (xy 168.998551 58.999493) + (xy 168.944698 58.953229) + (xy 168.924406 58.885194) + (xy 168.929846 58.84803) + (xy 168.930443 58.846067) (xy 168.97237 58.708069) (xy 169.001529 58.48659) - (xy 169.001664 58.481067) - (xy 169.001817 58.480589) - (xy 169.001871 58.479896) - (xy 169.002035 58.479909) - (xy 169.023325 58.413455) - (xy 169.078101 58.368287) - (xy 169.1486 58.359904) - (xy 169.216721 58.395051) - (xy 169.945484 59.123814) - (xy 169.951337 59.130079) - (xy 169.986771 59.170698) - (xy 170.035556 59.204984) - (xy 170.040841 59.20891) - (xy 170.081786 59.241015) - (xy 170.081792 59.241019) - (xy 170.087765 59.245702) - (xy 170.094685 59.248826) - (xy 170.100599 59.252408) - (xy 170.105836 59.255395) - (xy 170.111944 59.25867) - (xy 170.11816 59.263039) - (xy 170.125236 59.265798) - (xy 170.125242 59.265801) - (xy 170.173707 59.284696) - (xy 170.179762 59.287241) - (xy 170.234129 59.311789) - (xy 170.241594 59.313173) - (xy 170.248213 59.315247) - (xy 170.253963 59.316885) - (xy 170.260704 59.318615) - (xy 170.267782 59.321375) - (xy 170.275318 59.322367) - (xy 170.326888 59.329156) - (xy 170.333405 59.330188) - (xy 170.367331 59.336476) - (xy 170.392033 59.341054) - (xy 170.399613 59.340617) - (xy 170.399614 59.340617) - (xy 170.450048 59.337709) - (xy 170.457301 59.3375) - (xy 170.903658 59.3375) - (xy 170.971779 59.357502) - (xy 170.977714 59.361561) - (xy 171.0169 59.390031) + (xy 169.001744 58.477794) + (xy 169.001833 58.474163) + (xy 169.023495 58.406552) + (xy 169.078272 58.361385) + (xy 169.148772 58.353003) + (xy 169.21689 58.38815) + (xy 169.910345 59.081605) + (xy 169.918335 59.090385) + (xy 169.922584 59.09708) + (xy 169.928362 59.102506) + (xy 169.928363 59.102507) + (xy 169.974257 59.145604) + (xy 169.977099 59.148359) + (xy 169.997667 59.168927) + (xy 170.00117 59.171644) + (xy 170.010195 59.179352) + (xy 170.043867 59.210972) + (xy 170.050818 59.214793) + (xy 170.050819 59.214794) + (xy 170.062658 59.221303) + (xy 170.079182 59.232157) + (xy 170.089271 59.239982) + (xy 170.096132 59.245304) + (xy 170.103404 59.248451) + (xy 170.103406 59.248452) + (xy 170.138535 59.263654) + (xy 170.149195 59.268876) + (xy 170.181225 59.286485) + (xy 170.189663 59.291124) + (xy 170.210441 59.296459) + (xy 170.229131 59.302858) + (xy 170.248824 59.31138) + (xy 170.292596 59.318313) + (xy 170.294448 59.318606) + (xy 170.306071 59.321013) + (xy 170.334072 59.328202) + (xy 170.350812 59.3325) + (xy 170.372259 59.3325) + (xy 170.391969 59.334051) + (xy 170.413152 59.337406) + (xy 170.459141 59.333059) + (xy 170.470996 59.3325) + (xy 170.896776 59.3325) + (xy 170.964897 59.352502) + (xy 170.970834 59.356562) + (xy 170.983381 59.365678) (xy 171.109803 59.457529) (xy 171.120248 59.465118) (xy 171.126276 59.467802) @@ -7964,11 +7997,11 @@ (xy 172.044198 59.457529) (xy 172.091795 59.422947) (xy 172.188253 59.352866) - (xy 172.200135 59.33967) + (xy 172.216934 59.321013) (xy 172.311621 59.215852) (xy 172.311622 59.215851) (xy 172.31604 59.210944) - (xy 172.390508 59.081962) + (xy 172.390714 59.081605) (xy 172.408223 59.051279) (xy 172.408224 59.051278) (xy 172.411527 59.045556) @@ -8003,17 +8036,16 @@ (xy 171.126278 57.880197) (xy 171.126276 57.880198) (xy 171.120248 57.882882) - (xy 171.114907 57.886762) - (xy 171.114906 57.886763) - (xy 170.977719 57.986436) - (xy 170.910852 58.010294) - (xy 170.903658 58.0105) - (xy 170.76102 58.0105) - (xy 170.692899 57.990498) - (xy 170.671925 57.973595) - (xy 169.001104 56.302774) - (xy 168.967078 56.240462) - (xy 168.969642 56.177048) + (xy 170.971092 57.991251) + (xy 170.970837 57.991436) + (xy 170.903969 58.015294) + (xy 170.896776 58.0155) + (xy 170.75895 58.0155) + (xy 170.690829 57.995498) + (xy 170.669855 57.978595) + (xy 168.999457 56.308197) + (xy 168.965431 56.245885) + (xy 168.967994 56.182473) (xy 168.97237 56.168069) (xy 169.001529 55.94659) (xy 169.001663 55.941097) @@ -8024,58 +8056,58 @@ (xy 168.930431 55.440702) (xy 168.841354 55.23584) (xy 168.779372 55.14003) - (xy 171.5568 55.14003) - (xy 171.562527 55.14768) - (xy 171.747272 55.260893) - (xy 171.756067 55.265375) - (xy 171.97349 55.355434) - (xy 171.982875 55.358483) - (xy 172.211708 55.413422) - (xy 172.221455 55.414965) - (xy 172.45607 55.43343) - (xy 172.46593 55.43343) - (xy 172.700545 55.414965) - (xy 172.710292 55.413422) - (xy 172.939125 55.358483) - (xy 172.94851 55.355434) - (xy 173.165933 55.265375) - (xy 173.174728 55.260893) - (xy 173.355805 55.149928) - (xy 173.36476 55.14003) - (xy 176.6368 55.14003) - (xy 176.642527 55.14768) - (xy 176.827272 55.260893) - (xy 176.836067 55.265375) - (xy 177.05349 55.355434) - (xy 177.062875 55.358483) - (xy 177.291708 55.413422) - (xy 177.301455 55.414965) - (xy 177.53607 55.43343) - (xy 177.54593 55.43343) - (xy 177.780545 55.414965) - (xy 177.790292 55.413422) - (xy 178.019125 55.358483) - (xy 178.02851 55.355434) - (xy 178.245933 55.265375) - (xy 178.254728 55.260893) - (xy 178.435805 55.149928) - (xy 178.445267 55.13947) - (xy 178.441484 55.130694) - (xy 177.553812 54.243022) - (xy 177.539868 54.235408) - (xy 177.538035 54.235539) - (xy 177.53142 54.23979) - (xy 176.64356 55.12765) - (xy 176.6368 55.14003) - (xy 173.36476 55.14003) - (xy 173.365267 55.13947) - (xy 173.361484 55.130694) - (xy 172.473812 54.243022) - (xy 172.459868 54.235408) - (xy 172.458035 54.235539) - (xy 172.45142 54.23979) - (xy 171.56356 55.12765) - (xy 171.5568 55.14003) + (xy 171.6068 55.14003) + (xy 171.612527 55.14768) + (xy 171.797272 55.260893) + (xy 171.806067 55.265375) + (xy 172.02349 55.355434) + (xy 172.032875 55.358483) + (xy 172.261708 55.413422) + (xy 172.271455 55.414965) + (xy 172.50607 55.43343) + (xy 172.51593 55.43343) + (xy 172.750545 55.414965) + (xy 172.760292 55.413422) + (xy 172.989125 55.358483) + (xy 172.99851 55.355434) + (xy 173.215933 55.265375) + (xy 173.224728 55.260893) + (xy 173.405805 55.149928) + (xy 173.41476 55.14003) + (xy 176.6868 55.14003) + (xy 176.692527 55.14768) + (xy 176.877272 55.260893) + (xy 176.886067 55.265375) + (xy 177.10349 55.355434) + (xy 177.112875 55.358483) + (xy 177.341708 55.413422) + (xy 177.351455 55.414965) + (xy 177.58607 55.43343) + (xy 177.59593 55.43343) + (xy 177.830545 55.414965) + (xy 177.840292 55.413422) + (xy 178.069125 55.358483) + (xy 178.07851 55.355434) + (xy 178.295933 55.265375) + (xy 178.304728 55.260893) + (xy 178.485805 55.149928) + (xy 178.495267 55.13947) + (xy 178.491484 55.130694) + (xy 177.603812 54.243022) + (xy 177.589868 54.235408) + (xy 177.588035 54.235539) + (xy 177.58142 54.23979) + (xy 176.69356 55.12765) + (xy 176.6868 55.14003) + (xy 173.41476 55.14003) + (xy 173.415267 55.13947) + (xy 173.411484 55.130694) + (xy 172.523812 54.243022) + (xy 172.509868 54.235408) + (xy 172.508035 54.235539) + (xy 172.50142 54.23979) + (xy 171.61356 55.12765) + (xy 171.6068 55.14003) (xy 168.779372 55.14003) (xy 168.722822 55.052617) (xy 168.72282 55.052614) @@ -8159,62 +8191,52 @@ (xy 166.29011 58.609715) (xy 166.291247 58.614761) (xy 166.291248 58.614767) - (xy 166.309835 58.69724) - (xy 166.339222 58.827639) - (xy 166.341164 58.832422) - (xy 166.341166 58.832428) - (xy 166.341846 58.834102) - (xy 166.341919 58.83483) - (xy 166.342714 58.837367) - (xy 166.34219 58.837531) - (xy 166.348939 58.904743) - (xy 166.316714 58.968005) - (xy 166.255403 59.003803) - (xy 166.225101 59.007501) - (xy 161.615309 59.007501) - (xy 161.606739 59.007209) - (xy 161.560556 59.00406) - (xy 161.560552 59.00406) - (xy 161.55298 59.003544) - (xy 161.494218 59.013799) - (xy 161.487726 59.014757) - (xy 161.459237 59.018205) - (xy 161.436073 59.021008) - (xy 161.436071 59.021009) - (xy 161.428531 59.021921) - (xy 161.421431 59.024604) - (xy 161.414688 59.02626) - (xy 161.408908 59.027842) - (xy 161.402256 59.02985) - (xy 161.394779 59.031155) - (xy 161.387833 59.034204) - (xy 161.38783 59.034205) - (xy 161.361972 59.045556) - (xy 161.341265 59.054646) - (xy 161.340185 59.05512) - (xy 161.334082 59.05761) - (xy 161.278305 59.078686) - (xy 161.272041 59.082991) - (xy 161.265867 59.086219) - (xy 161.260642 59.089127) - (xy 161.254679 59.092654) - (xy 161.24773 59.095704) - (xy 161.241704 59.100328) - (xy 161.200444 59.131988) - (xy 161.195108 59.135865) - (xy 161.152222 59.16534) - (xy 161.152216 59.165345) - (xy 161.145957 59.169647) - (xy 161.136706 59.18003) - (xy 161.107296 59.213039) - (xy 161.102315 59.218315) - (xy 159.032394 61.288236) - (xy 158.970082 61.322262) - (xy 158.943299 61.325141) - (xy 158.929833 61.325141) - (xy 158.923381 61.326513) - (xy 158.923376 61.326513) - (xy 158.836433 61.344994) + (xy 166.334976 58.8088) + (xy 166.33044 58.879652) + (xy 166.288318 58.936803) + (xy 166.221985 58.962109) + (xy 166.212059 58.962501) + (xy 161.616872 58.962501) + (xy 161.608302 58.962209) + (xy 161.558184 58.958792) + (xy 161.55818 58.958792) + (xy 161.550608 58.958276) + (xy 161.543131 58.959581) + (xy 161.54313 58.959581) + (xy 161.539343 58.960242) + (xy 161.487663 58.969262) + (xy 161.481146 58.970223) + (xy 161.417718 58.977899) + (xy 161.41061 58.980585) + (xy 161.408016 58.981222) + (xy 161.39171 58.985683) + (xy 161.389159 58.986453) + (xy 161.381676 58.987759) + (xy 161.374724 58.990811) + (xy 161.374723 58.990811) + (xy 161.323172 59.01344) + (xy 161.317065 59.015932) + (xy 161.264412 59.035828) + (xy 161.257304 59.038514) + (xy 161.251043 59.042817) + (xy 161.248677 59.044054) + (xy 161.233897 59.052281) + (xy 161.231612 59.053632) + (xy 161.224655 59.056686) + (xy 161.218635 59.061306) + (xy 161.218629 59.061309) + (xy 161.187502 59.085195) + (xy 161.173958 59.095588) + (xy 161.168628 59.09946) + (xy 161.12224 59.13134) + (xy 161.122235 59.131345) + (xy 161.115979 59.135644) + (xy 161.110928 59.141314) + (xy 161.110926 59.141315) + (xy 161.074525 59.182171) + (xy 161.069544 59.187447) + (xy 158.958787 61.298204) + (xy 158.895889 61.332356) (xy 158.743032 61.364847) (xy 158.737002 61.367532) (xy 158.737001 61.367532) @@ -8278,19 +8300,22 @@ (xy 159.856543 62.61092) (xy 159.856544 62.610919) (xy 159.859847 62.605197) + (xy 159.893207 62.502526) + (xy 159.916822 62.429848) + (xy 159.916822 62.429846) (xy 159.918862 62.423569) - (xy 159.922842 62.385706) - (xy 159.931244 62.305757) - (xy 159.958257 62.2401) - (xy 159.967459 62.229832) - (xy 161.825886 60.371406) - (xy 161.888198 60.33738) - (xy 161.914981 60.334501) - (xy 166.237921 60.334501) - (xy 166.306042 60.354503) - (xy 166.352535 60.408159) - (xy 166.362639 60.478433) - (xy 166.359338 60.494173) + (xy 159.92377 62.376871) + (xy 159.950783 62.311214) + (xy 159.959985 62.300946) + (xy 161.844526 60.416406) + (xy 161.906838 60.38238) + (xy 161.933621 60.379501) + (xy 166.225441 60.379501) + (xy 166.293562 60.399503) + (xy 166.340055 60.453159) + (xy 166.350159 60.523433) + (xy 166.346858 60.539173) + (xy 166.340666 60.561502) (xy 166.300989 60.70457) (xy 166.277251 60.926695) (xy 166.277548 60.931848) @@ -8318,7 +8343,7 @@ (xy 166.913607 62.346507) (xy 166.909474 62.34961) (xy 166.909471 62.349612) - (xy 166.7391 62.47753) + (xy 166.775098 62.450502) (xy 166.734965 62.480635) (xy 166.701358 62.515803) (xy 166.591751 62.6305) @@ -8511,8 +8536,6 @@ (xy 163.327232 67.634633) (xy 163.326542 67.628072) (xy 163.267527 67.446444) - (xy 163.252416 67.42027) - (xy 163.219099 67.362564) (xy 163.17204 67.281056) (xy 163.138975 67.244333) (xy 163.048675 67.144045) @@ -8549,8 +8572,6 @@ (xy 161.817325 67.144045) (xy 161.727026 67.244333) (xy 161.69396 67.281056) - (xy 161.646901 67.362564) - (xy 161.613585 67.42027) (xy 161.598473 67.446444) (xy 161.539458 67.628072) (xy 161.538768 67.634633) @@ -8619,7 +8640,7 @@ (xy 153.048312 77.461921) (xy 153.073428 77.395516) (xy 153.10078 77.368909) - (xy 153.144603 77.33765) + (xy 153.182888 77.310342) (xy 153.27986 77.241173) (xy 153.438096 77.083489) (xy 153.461164 77.051387) @@ -8634,7 +8655,7 @@ (xy 153.730865 76.493021) (xy 153.73237 76.488069) (xy 153.761529 76.26659) - (xy 153.761754 76.257401) + (xy 153.761611 76.26324) (xy 153.763074 76.203365) (xy 153.763074 76.203361) (xy 153.763156 76.2) @@ -8661,7 +8682,7 @@ (xy 153.44671 74.531502) (xy 153.565435 74.366277) (xy 153.568453 74.362077) - (xy 153.571195 74.35653) + (xy 153.572436 74.354019) (xy 153.665136 74.166453) (xy 153.665137 74.166451) (xy 153.66743 74.161811) @@ -8692,10 +8713,10 @@ (xy 153.161358 72.245699) (xy 153.27986 72.161173) (xy 153.438096 72.003489) - (xy 153.443115 71.996505) + (xy 153.444688 71.994316) (xy 153.565435 71.826277) (xy 153.568453 71.822077) - (xy 153.585469 71.787649) + (xy 153.586791 71.784974) (xy 153.665136 71.626453) (xy 153.665137 71.626451) (xy 153.66743 71.621811) @@ -8711,7 +8732,7 @@ (xy 153.744852 70.897361) (xy 153.690431 70.680702) (xy 153.601354 70.47584) - (xy 153.508288 70.331982) + (xy 153.541771 70.383738) (xy 153.482822 70.292617) (xy 153.48282 70.292614) (xy 153.480014 70.288277) @@ -8726,7 +8747,7 @@ (xy 153.048312 69.841921) (xy 153.073428 69.775516) (xy 153.10078 69.748909) - (xy 153.163042 69.704498) + (xy 153.144603 69.71765) (xy 153.27986 69.621173) (xy 153.297767 69.603329) (xy 153.376309 69.52506) @@ -8968,7 +8989,7 @@ (xy 153.730865 61.253022) (xy 153.73237 61.248069) (xy 153.761529 61.02659) - (xy 153.761762 61.017065) + (xy 153.762338 60.993498) (xy 153.763074 60.963365) (xy 153.763074 60.963361) (xy 153.763156 60.96) @@ -8993,7 +9014,7 @@ (xy 153.169195 59.540109) (xy 153.27986 59.461173) (xy 153.438096 59.303489) - (xy 153.465178 59.265801) + (xy 153.479318 59.246123) (xy 153.565435 59.126277) (xy 153.568453 59.122077) (xy 153.581173 59.096341) @@ -9063,7 +9084,7 @@ (xy 153.16511 54.463023) (xy 153.27986 54.381173) (xy 153.302603 54.35851) - (xy 153.361209 54.300107) + (xy 153.387003 54.274404) (xy 153.438096 54.223489) (xy 153.479318 54.166123) (xy 153.565435 54.046277) @@ -9072,9 +9093,6 @@ (xy 153.665136 53.846453) (xy 153.665137 53.846451) (xy 153.66743 53.841811) - (xy 153.720751 53.666311) - (xy 153.730865 53.633023) - (xy 153.730865 53.633021) (xy 153.73237 53.628069) (xy 153.761529 53.40659) (xy 153.761901 53.391358) @@ -9103,111 +9121,111 @@ (xy 168.805004 54.046019) (xy 168.810315 54.03718) (xy 168.89001 53.87593) - (xy 170.89857 53.87593) - (xy 170.917035 54.110545) - (xy 170.918578 54.120292) - (xy 170.973517 54.349125) - (xy 170.976566 54.35851) - (xy 171.066625 54.575933) - (xy 171.071107 54.584728) - (xy 171.182072 54.765805) - (xy 171.19253 54.775267) - (xy 171.201306 54.771484) - (xy 172.088978 53.883812) - (xy 172.095356 53.872132) - (xy 172.825408 53.872132) - (xy 172.825539 53.873965) - (xy 172.82979 53.88058) - (xy 173.71765 54.76844) - (xy 173.73003 54.7752) - (xy 173.73768 54.769473) - (xy 173.850893 54.584728) - (xy 173.855375 54.575933) - (xy 173.945434 54.35851) - (xy 173.948483 54.349125) - (xy 174.003422 54.120292) - (xy 174.004965 54.110545) - (xy 174.02343 53.87593) - (xy 175.97857 53.87593) - (xy 175.997035 54.110545) - (xy 175.998578 54.120292) - (xy 176.053517 54.349125) - (xy 176.056566 54.35851) - (xy 176.146625 54.575933) - (xy 176.151107 54.584728) - (xy 176.262072 54.765805) - (xy 176.27253 54.775267) - (xy 176.281306 54.771484) - (xy 177.168978 53.883812) - (xy 177.175356 53.872132) - (xy 177.905408 53.872132) - (xy 177.905539 53.873965) - (xy 177.90979 53.88058) - (xy 178.79765 54.76844) - (xy 178.81003 54.7752) - (xy 178.81768 54.769473) - (xy 178.930893 54.584728) - (xy 178.935375 54.575933) - (xy 179.025434 54.35851) - (xy 179.028483 54.349125) - (xy 179.083422 54.120292) - (xy 179.084965 54.110545) - (xy 179.10343 53.87593) - (xy 179.10343 53.86607) - (xy 179.084965 53.631455) - (xy 179.083422 53.621708) - (xy 179.028483 53.392875) - (xy 179.025434 53.38349) - (xy 178.935375 53.166067) - (xy 178.930893 53.157272) - (xy 178.819928 52.976195) - (xy 178.80947 52.966733) - (xy 178.800694 52.970516) - (xy 177.913022 53.858188) - (xy 177.905408 53.872132) - (xy 177.175356 53.872132) - (xy 177.176592 53.869868) - (xy 177.176461 53.868035) - (xy 177.17221 53.86142) - (xy 176.28435 52.97356) - (xy 176.27197 52.9668) - (xy 176.26432 52.972527) - (xy 176.151107 53.157272) - (xy 176.146625 53.166067) - (xy 176.056566 53.38349) - (xy 176.053517 53.392875) - (xy 175.998578 53.621708) - (xy 175.997035 53.631455) - (xy 175.97857 53.86607) - (xy 175.97857 53.87593) - (xy 174.02343 53.87593) - (xy 174.02343 53.86607) - (xy 174.004965 53.631455) - (xy 174.003422 53.621708) - (xy 173.948483 53.392875) - (xy 173.945434 53.38349) - (xy 173.855375 53.166067) - (xy 173.850893 53.157272) - (xy 173.739928 52.976195) - (xy 173.72947 52.966733) - (xy 173.720694 52.970516) - (xy 172.833022 53.858188) - (xy 172.825408 53.872132) - (xy 172.095356 53.872132) - (xy 172.096592 53.869868) - (xy 172.096461 53.868035) - (xy 172.09221 53.86142) - (xy 171.20435 52.97356) - (xy 171.19197 52.9668) - (xy 171.18432 52.972527) - (xy 171.071107 53.157272) - (xy 171.066625 53.166067) - (xy 170.976566 53.38349) - (xy 170.973517 53.392875) - (xy 170.918578 53.621708) - (xy 170.917035 53.631455) - (xy 170.89857 53.86607) - (xy 170.89857 53.87593) + (xy 170.94857 53.87593) + (xy 170.967035 54.110545) + (xy 170.968578 54.120292) + (xy 171.023517 54.349125) + (xy 171.026566 54.35851) + (xy 171.116625 54.575933) + (xy 171.121107 54.584728) + (xy 171.232072 54.765805) + (xy 171.24253 54.775267) + (xy 171.251306 54.771484) + (xy 172.138978 53.883812) + (xy 172.145356 53.872132) + (xy 172.875408 53.872132) + (xy 172.875539 53.873965) + (xy 172.87979 53.88058) + (xy 173.76765 54.76844) + (xy 173.78003 54.7752) + (xy 173.78768 54.769473) + (xy 173.900893 54.584728) + (xy 173.905375 54.575933) + (xy 173.995434 54.35851) + (xy 173.998483 54.349125) + (xy 174.053422 54.120292) + (xy 174.054965 54.110545) + (xy 174.07343 53.87593) + (xy 176.02857 53.87593) + (xy 176.047035 54.110545) + (xy 176.048578 54.120292) + (xy 176.103517 54.349125) + (xy 176.106566 54.35851) + (xy 176.196625 54.575933) + (xy 176.201107 54.584728) + (xy 176.312072 54.765805) + (xy 176.32253 54.775267) + (xy 176.331306 54.771484) + (xy 177.218978 53.883812) + (xy 177.225356 53.872132) + (xy 177.955408 53.872132) + (xy 177.955539 53.873965) + (xy 177.95979 53.88058) + (xy 178.84765 54.76844) + (xy 178.86003 54.7752) + (xy 178.86768 54.769473) + (xy 178.980893 54.584728) + (xy 178.985375 54.575933) + (xy 179.075434 54.35851) + (xy 179.078483 54.349125) + (xy 179.133422 54.120292) + (xy 179.134965 54.110545) + (xy 179.15343 53.87593) + (xy 179.15343 53.86607) + (xy 179.134965 53.631455) + (xy 179.133422 53.621708) + (xy 179.078483 53.392875) + (xy 179.075434 53.38349) + (xy 178.985375 53.166067) + (xy 178.980893 53.157272) + (xy 178.869928 52.976195) + (xy 178.85947 52.966733) + (xy 178.850694 52.970516) + (xy 177.963022 53.858188) + (xy 177.955408 53.872132) + (xy 177.225356 53.872132) + (xy 177.226592 53.869868) + (xy 177.226461 53.868035) + (xy 177.22221 53.86142) + (xy 176.33435 52.97356) + (xy 176.32197 52.9668) + (xy 176.31432 52.972527) + (xy 176.201107 53.157272) + (xy 176.196625 53.166067) + (xy 176.106566 53.38349) + (xy 176.103517 53.392875) + (xy 176.048578 53.621708) + (xy 176.047035 53.631455) + (xy 176.02857 53.86607) + (xy 176.02857 53.87593) + (xy 174.07343 53.87593) + (xy 174.07343 53.86607) + (xy 174.054965 53.631455) + (xy 174.053422 53.621708) + (xy 173.998483 53.392875) + (xy 173.995434 53.38349) + (xy 173.905375 53.166067) + (xy 173.900893 53.157272) + (xy 173.789928 52.976195) + (xy 173.77947 52.966733) + (xy 173.770694 52.970516) + (xy 172.883022 53.858188) + (xy 172.875408 53.872132) + (xy 172.145356 53.872132) + (xy 172.146592 53.869868) + (xy 172.146461 53.868035) + (xy 172.14221 53.86142) + (xy 171.25435 52.97356) + (xy 171.24197 52.9668) + (xy 171.23432 52.972527) + (xy 171.121107 53.157272) + (xy 171.116625 53.166067) + (xy 171.026566 53.38349) + (xy 171.023517 53.392875) + (xy 170.968578 53.621708) + (xy 170.967035 53.631455) + (xy 170.94857 53.86607) + (xy 170.94857 53.87593) (xy 168.89001 53.87593) (xy 168.90467 53.846267) (xy 168.908469 53.836672) @@ -9224,58 +9242,58 @@ (xy 168.842972 52.700814) (xy 168.838105 52.691739) (xy 168.780394 52.60253) - (xy 171.556733 52.60253) - (xy 171.560516 52.611306) - (xy 172.448188 53.498978) - (xy 172.462132 53.506592) - (xy 172.463965 53.506461) - (xy 172.47058 53.50221) - (xy 173.35844 52.61435) - (xy 173.364894 52.60253) - (xy 176.636733 52.60253) - (xy 176.640516 52.611306) - (xy 177.528188 53.498978) - (xy 177.542132 53.506592) - (xy 177.543965 53.506461) - (xy 177.55058 53.50221) - (xy 178.43844 52.61435) - (xy 178.4452 52.60197) - (xy 178.439473 52.59432) - (xy 178.254728 52.481107) - (xy 178.245933 52.476625) - (xy 178.02851 52.386566) - (xy 178.019125 52.383517) - (xy 177.790292 52.328578) - (xy 177.780545 52.327035) - (xy 177.54593 52.30857) - (xy 177.53607 52.30857) - (xy 177.301455 52.327035) - (xy 177.291708 52.328578) - (xy 177.062875 52.383517) - (xy 177.05349 52.386566) - (xy 176.836067 52.476625) - (xy 176.827272 52.481107) - (xy 176.646195 52.592072) - (xy 176.636733 52.60253) - (xy 173.364894 52.60253) - (xy 173.3652 52.60197) - (xy 173.359473 52.59432) - (xy 173.174728 52.481107) - (xy 173.165933 52.476625) - (xy 172.94851 52.386566) - (xy 172.939125 52.383517) - (xy 172.710292 52.328578) - (xy 172.700545 52.327035) - (xy 172.46593 52.30857) - (xy 172.45607 52.30857) - (xy 172.221455 52.327035) - (xy 172.211708 52.328578) - (xy 171.982875 52.383517) - (xy 171.97349 52.386566) - (xy 171.756067 52.476625) - (xy 171.747272 52.481107) - (xy 171.566195 52.592072) - (xy 171.556733 52.60253) + (xy 171.606733 52.60253) + (xy 171.610516 52.611306) + (xy 172.498188 53.498978) + (xy 172.512132 53.506592) + (xy 172.513965 53.506461) + (xy 172.52058 53.50221) + (xy 173.40844 52.61435) + (xy 173.414894 52.60253) + (xy 176.686733 52.60253) + (xy 176.690516 52.611306) + (xy 177.578188 53.498978) + (xy 177.592132 53.506592) + (xy 177.593965 53.506461) + (xy 177.60058 53.50221) + (xy 178.48844 52.61435) + (xy 178.4952 52.60197) + (xy 178.489473 52.59432) + (xy 178.304728 52.481107) + (xy 178.295933 52.476625) + (xy 178.07851 52.386566) + (xy 178.069125 52.383517) + (xy 177.840292 52.328578) + (xy 177.830545 52.327035) + (xy 177.59593 52.30857) + (xy 177.58607 52.30857) + (xy 177.351455 52.327035) + (xy 177.341708 52.328578) + (xy 177.112875 52.383517) + (xy 177.10349 52.386566) + (xy 176.886067 52.476625) + (xy 176.877272 52.481107) + (xy 176.696195 52.592072) + (xy 176.686733 52.60253) + (xy 173.414894 52.60253) + (xy 173.4152 52.60197) + (xy 173.409473 52.59432) + (xy 173.224728 52.481107) + (xy 173.215933 52.476625) + (xy 172.99851 52.386566) + (xy 172.989125 52.383517) + (xy 172.760292 52.328578) + (xy 172.750545 52.327035) + (xy 172.51593 52.30857) + (xy 172.50607 52.30857) + (xy 172.271455 52.327035) + (xy 172.261708 52.328578) + (xy 172.032875 52.383517) + (xy 172.02349 52.386566) + (xy 171.806067 52.476625) + (xy 171.797272 52.481107) + (xy 171.616195 52.592072) + (xy 171.606733 52.60253) (xy 168.780394 52.60253) (xy 168.773063 52.591197) (xy 168.762377 52.581995) @@ -9389,58 +9407,58 @@ (xy 168.842972 50.160814) (xy 168.838105 50.151739) (xy 168.778777 50.06003) - (xy 171.5568 50.06003) - (xy 171.562527 50.06768) - (xy 171.747272 50.180893) - (xy 171.756067 50.185375) - (xy 171.97349 50.275434) - (xy 171.982875 50.278483) - (xy 172.211708 50.333422) - (xy 172.221455 50.334965) - (xy 172.45607 50.35343) - (xy 172.46593 50.35343) - (xy 172.700545 50.334965) - (xy 172.710292 50.333422) - (xy 172.939125 50.278483) - (xy 172.94851 50.275434) - (xy 173.165933 50.185375) - (xy 173.174728 50.180893) - (xy 173.355805 50.069928) - (xy 173.36476 50.06003) - (xy 176.6368 50.06003) - (xy 176.642527 50.06768) - (xy 176.827272 50.180893) - (xy 176.836067 50.185375) - (xy 177.05349 50.275434) - (xy 177.062875 50.278483) - (xy 177.291708 50.333422) - (xy 177.301455 50.334965) - (xy 177.53607 50.35343) - (xy 177.54593 50.35343) - (xy 177.780545 50.334965) - (xy 177.790292 50.333422) - (xy 178.019125 50.278483) - (xy 178.02851 50.275434) - (xy 178.245933 50.185375) - (xy 178.254728 50.180893) - (xy 178.435805 50.069928) - (xy 178.445267 50.05947) - (xy 178.441484 50.050694) - (xy 177.553812 49.163022) - (xy 177.539868 49.155408) - (xy 177.538035 49.155539) - (xy 177.53142 49.15979) - (xy 176.64356 50.04765) - (xy 176.6368 50.06003) - (xy 173.36476 50.06003) - (xy 173.365267 50.05947) - (xy 173.361484 50.050694) - (xy 172.473812 49.163022) - (xy 172.459868 49.155408) - (xy 172.458035 49.155539) - (xy 172.45142 49.15979) - (xy 171.56356 50.04765) - (xy 171.5568 50.06003) + (xy 171.6068 50.06003) + (xy 171.612527 50.06768) + (xy 171.797272 50.180893) + (xy 171.806067 50.185375) + (xy 172.02349 50.275434) + (xy 172.032875 50.278483) + (xy 172.261708 50.333422) + (xy 172.271455 50.334965) + (xy 172.50607 50.35343) + (xy 172.51593 50.35343) + (xy 172.750545 50.334965) + (xy 172.760292 50.333422) + (xy 172.989125 50.278483) + (xy 172.99851 50.275434) + (xy 173.215933 50.185375) + (xy 173.224728 50.180893) + (xy 173.405805 50.069928) + (xy 173.41476 50.06003) + (xy 176.6868 50.06003) + (xy 176.692527 50.06768) + (xy 176.877272 50.180893) + (xy 176.886067 50.185375) + (xy 177.10349 50.275434) + (xy 177.112875 50.278483) + (xy 177.341708 50.333422) + (xy 177.351455 50.334965) + (xy 177.58607 50.35343) + (xy 177.59593 50.35343) + (xy 177.830545 50.334965) + (xy 177.840292 50.333422) + (xy 178.069125 50.278483) + (xy 178.07851 50.275434) + (xy 178.295933 50.185375) + (xy 178.304728 50.180893) + (xy 178.485805 50.069928) + (xy 178.495267 50.05947) + (xy 178.491484 50.050694) + (xy 177.603812 49.163022) + (xy 177.589868 49.155408) + (xy 177.588035 49.155539) + (xy 177.58142 49.15979) + (xy 176.69356 50.04765) + (xy 176.6868 50.06003) + (xy 173.41476 50.06003) + (xy 173.415267 50.05947) + (xy 173.411484 50.050694) + (xy 172.523812 49.163022) + (xy 172.509868 49.155408) + (xy 172.508035 49.155539) + (xy 172.50142 49.15979) + (xy 171.61356 50.04765) + (xy 171.6068 50.06003) (xy 168.778777 50.06003) (xy 168.773063 50.051197) (xy 168.762377 50.041995) @@ -9517,11 +9535,8 @@ (xy 151.501916 52.253738) (xy 151.486709 52.323087) (xy 151.467316 52.349568) - (xy 151.394819 52.425432) + (xy 151.434874 52.383517) (xy 151.340629 52.482138) - (xy 151.337715 52.48641) - (xy 151.337714 52.486411) - (xy 151.325409 52.50445) (xy 151.214743 52.66668) (xy 151.176512 52.749043) (xy 151.139471 52.828841) @@ -9579,8 +9594,10 @@ (xy 142.542899 50.654498) (xy 142.496406 50.600842) (xy 142.491187 50.587436) - (xy 142.47567 50.539681) + (xy 142.472191 50.528972) (xy 142.439527 50.428444) + (xy 142.424853 50.403027) + (xy 142.347341 50.268774) (xy 142.34404 50.263056) (xy 142.216253 50.121134) (xy 142.061752 50.008882) @@ -9635,6 +9652,8 @@ (xy 139.497248 50.008882) (xy 139.342747 50.121134) (xy 139.21496 50.263056) + (xy 139.211659 50.268774) + (xy 139.134148 50.403027) (xy 139.119473 50.428444) (xy 139.060458 50.610072) (xy 139.059768 50.616633) @@ -9652,7 +9671,7 @@ (xy 139.497248 51.591118) (xy 139.503276 51.593802) (xy 139.503278 51.593803) - (xy 139.665681 51.666109) + (xy 139.580996 51.628405) (xy 139.671712 51.668794) (xy 139.765113 51.688647) (xy 139.852056 51.707128) @@ -9719,10 +9738,10 @@ (xy 151.069835 58.69724) (xy 151.099222 58.827639) (xy 151.151955 58.957506) - (xy 151.170859 59.00406) + (xy 151.163397 58.985683) (xy 151.183266 59.034616) - (xy 151.218471 59.092066) - (xy 151.295837 59.218315) + (xy 151.224547 59.101981) + (xy 151.291337 59.210972) (xy 151.299987 59.225088) (xy 151.44625 59.393938) (xy 151.618126 59.536632) @@ -9745,7 +9764,7 @@ (xy 151.290025 60.17632) (xy 151.214743 60.28668) (xy 151.176011 60.370121) - (xy 151.125735 60.478433) + (xy 151.127777 60.474034) (xy 151.120688 60.489305) (xy 151.060989 60.70457) (xy 151.037251 60.926695) @@ -9822,7 +9841,7 @@ (xy 145.708429 58.142774) (xy 145.814435 58.037137) (xy 145.818096 58.033489) - (xy 145.926318 57.882882) + (xy 145.831171 58.015294) (xy 145.945435 57.856277) (xy 145.948453 57.852077) (xy 145.981952 57.784298) @@ -10014,156 +10033,157 @@ (xy 132.5795 53.214595) (xy 132.517188 53.248621) (xy 132.490405 53.2515) - (xy 131.9505 53.2515) - (xy 131.882379 53.231498) - (xy 131.835886 53.177842) - (xy 131.8245 53.1255) - (xy 131.8245 52.783768) - (xy 131.825027 52.772585) - (xy 131.826702 52.765092) - (xy 131.826232 52.750121) - (xy 131.824562 52.697002) - (xy 131.8245 52.693044) - (xy 131.8245 52.665144) - (xy 131.823996 52.661153) - (xy 131.823063 52.649311) - (xy 131.82231 52.62533) - (xy 131.821674 52.605111) - (xy 131.817632 52.591197) - (xy 131.816021 52.585652) - (xy 131.812012 52.566293) - (xy 131.811846 52.564983) - (xy 131.809474 52.546203) - (xy 131.806558 52.538837) - (xy 131.806556 52.538831) - (xy 131.7932 52.505098) - (xy 131.789355 52.493868) - (xy 131.77923 52.459017) - (xy 131.77923 52.459016) - (xy 131.777019 52.451407) - (xy 131.766705 52.433966) - (xy 131.758008 52.416213) - (xy 131.753472 52.404758) - (xy 131.750552 52.397383) - (xy 131.724563 52.361612) - (xy 131.718047 52.351692) - (xy 131.716791 52.349568) - (xy 131.695542 52.313638) - (xy 131.681221 52.299317) - (xy 131.66838 52.284283) - (xy 131.661131 52.274306) - (xy 131.656472 52.267893) - (xy 131.622395 52.239702) - (xy 131.613616 52.231712) - (xy 129.285405 49.9035) - (xy 129.251379 49.841188) - (xy 129.2485 49.814405) + (xy 131.542594 53.2515) + (xy 131.474473 53.231498) + (xy 131.453499 53.214595) + (xy 129.956405 51.7175) + (xy 129.922379 51.655188) + (xy 129.9195 51.628405) + (xy 129.9195 50.878768) + (xy 129.920027 50.867585) + (xy 129.921702 50.860092) + (xy 129.919562 50.792001) + (xy 129.9195 50.788044) + (xy 129.9195 50.760144) + (xy 129.918996 50.756153) + (xy 129.918063 50.744311) + (xy 129.917954 50.740826) + (xy 129.916674 50.700111) + (xy 129.914462 50.692497) + (xy 129.914461 50.692492) + (xy 129.911023 50.680659) + (xy 129.907012 50.661295) + (xy 129.905467 50.649064) + (xy 129.904474 50.641203) + (xy 129.901557 50.633836) + (xy 129.901556 50.633831) + (xy 129.888198 50.600092) + (xy 129.884354 50.588865) + (xy 129.87423 50.554022) + (xy 129.872018 50.546407) + (xy 129.861707 50.528972) + (xy 129.853012 50.511224) + (xy 129.845552 50.492383) + (xy 129.819564 50.456613) + (xy 129.813048 50.446693) + (xy 129.79458 50.415465) + (xy 129.794578 50.415462) + (xy 129.790542 50.408638) + (xy 129.776221 50.394317) + (xy 129.76338 50.379283) + (xy 129.756131 50.369306) + (xy 129.751472 50.362893) + (xy 129.717395 50.334702) + (xy 129.708616 50.326712) + (xy 129.285405 49.903501) + (xy 129.251379 49.841189) + (xy 129.2485 49.814406) (xy 129.2485 48.79593) - (xy 170.89857 48.79593) - (xy 170.917035 49.030545) - (xy 170.918578 49.040292) - (xy 170.973517 49.269125) - (xy 170.976566 49.27851) - (xy 171.066625 49.495933) - (xy 171.071107 49.504728) - (xy 171.182072 49.685805) - (xy 171.19253 49.695267) - (xy 171.201306 49.691484) - (xy 172.088978 48.803812) - (xy 172.095356 48.792132) - (xy 172.825408 48.792132) - (xy 172.825539 48.793965) - (xy 172.82979 48.80058) - (xy 173.71765 49.68844) - (xy 173.73003 49.6952) - (xy 173.73768 49.689473) - (xy 173.850893 49.504728) - (xy 173.855375 49.495933) - (xy 173.945434 49.27851) - (xy 173.948483 49.269125) - (xy 174.003422 49.040292) - (xy 174.004965 49.030545) - (xy 174.02343 48.79593) - (xy 175.97857 48.79593) - (xy 175.997035 49.030545) - (xy 175.998578 49.040292) - (xy 176.053517 49.269125) - (xy 176.056566 49.27851) - (xy 176.146625 49.495933) - (xy 176.151107 49.504728) - (xy 176.262072 49.685805) - (xy 176.27253 49.695267) - (xy 176.281306 49.691484) - (xy 177.168978 48.803812) - (xy 177.175356 48.792132) - (xy 177.905408 48.792132) - (xy 177.905539 48.793965) - (xy 177.90979 48.80058) - (xy 178.79765 49.68844) - (xy 178.81003 49.6952) - (xy 178.81768 49.689473) - (xy 178.930893 49.504728) - (xy 178.935375 49.495933) - (xy 179.025434 49.27851) - (xy 179.028483 49.269125) - (xy 179.083422 49.040292) - (xy 179.084965 49.030545) - (xy 179.10343 48.79593) - (xy 179.10343 48.78607) - (xy 179.084965 48.551455) - (xy 179.083422 48.541708) - (xy 179.028483 48.312875) - (xy 179.025434 48.30349) - (xy 178.935375 48.086067) - (xy 178.930893 48.077272) - (xy 178.819928 47.896195) - (xy 178.80947 47.886733) - (xy 178.800694 47.890516) - (xy 177.913022 48.778188) - (xy 177.905408 48.792132) - (xy 177.175356 48.792132) - (xy 177.176592 48.789868) - (xy 177.176461 48.788035) - (xy 177.17221 48.78142) - (xy 176.28435 47.89356) - (xy 176.27197 47.8868) - (xy 176.26432 47.892527) - (xy 176.151107 48.077272) - (xy 176.146625 48.086067) - (xy 176.056566 48.30349) - (xy 176.053517 48.312875) - (xy 175.998578 48.541708) - (xy 175.997035 48.551455) - (xy 175.97857 48.78607) - (xy 175.97857 48.79593) - (xy 174.02343 48.79593) - (xy 174.02343 48.78607) - (xy 174.004965 48.551455) - (xy 174.003422 48.541708) - (xy 173.948483 48.312875) - (xy 173.945434 48.30349) - (xy 173.855375 48.086067) - (xy 173.850893 48.077272) - (xy 173.739928 47.896195) - (xy 173.72947 47.886733) - (xy 173.720694 47.890516) - (xy 172.833022 48.778188) - (xy 172.825408 48.792132) - (xy 172.095356 48.792132) - (xy 172.096592 48.789868) - (xy 172.096461 48.788035) - (xy 172.09221 48.78142) - (xy 171.20435 47.89356) - (xy 171.19197 47.8868) - (xy 171.18432 47.892527) - (xy 171.071107 48.077272) - (xy 171.066625 48.086067) - (xy 170.976566 48.30349) - (xy 170.973517 48.312875) - (xy 170.918578 48.541708) - (xy 170.917035 48.551455) - (xy 170.89857 48.78607) - (xy 170.89857 48.79593) + (xy 170.94857 48.79593) + (xy 170.967035 49.030545) + (xy 170.968578 49.040292) + (xy 171.023517 49.269125) + (xy 171.026566 49.27851) + (xy 171.116625 49.495933) + (xy 171.121107 49.504728) + (xy 171.232072 49.685805) + (xy 171.24253 49.695267) + (xy 171.251306 49.691484) + (xy 172.138978 48.803812) + (xy 172.145356 48.792132) + (xy 172.875408 48.792132) + (xy 172.875539 48.793965) + (xy 172.87979 48.80058) + (xy 173.76765 49.68844) + (xy 173.78003 49.6952) + (xy 173.78768 49.689473) + (xy 173.900893 49.504728) + (xy 173.905375 49.495933) + (xy 173.995434 49.27851) + (xy 173.998483 49.269125) + (xy 174.053422 49.040292) + (xy 174.054965 49.030545) + (xy 174.07343 48.79593) + (xy 176.02857 48.79593) + (xy 176.047035 49.030545) + (xy 176.048578 49.040292) + (xy 176.103517 49.269125) + (xy 176.106566 49.27851) + (xy 176.196625 49.495933) + (xy 176.201107 49.504728) + (xy 176.312072 49.685805) + (xy 176.32253 49.695267) + (xy 176.331306 49.691484) + (xy 177.218978 48.803812) + (xy 177.225356 48.792132) + (xy 177.955408 48.792132) + (xy 177.955539 48.793965) + (xy 177.95979 48.80058) + (xy 178.84765 49.68844) + (xy 178.86003 49.6952) + (xy 178.86768 49.689473) + (xy 178.980893 49.504728) + (xy 178.985375 49.495933) + (xy 179.075434 49.27851) + (xy 179.078483 49.269125) + (xy 179.133422 49.040292) + (xy 179.134965 49.030545) + (xy 179.15343 48.79593) + (xy 179.15343 48.78607) + (xy 179.134965 48.551455) + (xy 179.133422 48.541708) + (xy 179.078483 48.312875) + (xy 179.075434 48.30349) + (xy 178.985375 48.086067) + (xy 178.980893 48.077272) + (xy 178.869928 47.896195) + (xy 178.85947 47.886733) + (xy 178.850694 47.890516) + (xy 177.963022 48.778188) + (xy 177.955408 48.792132) + (xy 177.225356 48.792132) + (xy 177.226592 48.789868) + (xy 177.226461 48.788035) + (xy 177.22221 48.78142) + (xy 176.33435 47.89356) + (xy 176.32197 47.8868) + (xy 176.31432 47.892527) + (xy 176.201107 48.077272) + (xy 176.196625 48.086067) + (xy 176.106566 48.30349) + (xy 176.103517 48.312875) + (xy 176.048578 48.541708) + (xy 176.047035 48.551455) + (xy 176.02857 48.78607) + (xy 176.02857 48.79593) + (xy 174.07343 48.79593) + (xy 174.07343 48.78607) + (xy 174.054965 48.551455) + (xy 174.053422 48.541708) + (xy 173.998483 48.312875) + (xy 173.995434 48.30349) + (xy 173.905375 48.086067) + (xy 173.900893 48.077272) + (xy 173.789928 47.896195) + (xy 173.77947 47.886733) + (xy 173.770694 47.890516) + (xy 172.883022 48.778188) + (xy 172.875408 48.792132) + (xy 172.145356 48.792132) + (xy 172.146592 48.789868) + (xy 172.146461 48.788035) + (xy 172.14221 48.78142) + (xy 171.25435 47.89356) + (xy 171.24197 47.8868) + (xy 171.23432 47.892527) + (xy 171.121107 48.077272) + (xy 171.116625 48.086067) + (xy 171.026566 48.30349) + (xy 171.023517 48.312875) + (xy 170.968578 48.541708) + (xy 170.967035 48.551455) + (xy 170.94857 48.78607) + (xy 170.94857 48.79593) (xy 129.2485 48.79593) (xy 129.2485 48.448533) (xy 129.241745 48.386351) @@ -10195,7 +10215,135 @@ (xy 126.384059 47.500378) (xy 126.390286 47.499564) (xy 126.406621 47.4985) - (xy 171.47552 47.4985) + (xy 171.52552 47.4985) + ) + ) + (filled_polygon + (layer "F.Cu") + (pts + (xy 164.892532 74.613539) + (xy 164.949368 74.656086) + (xy 164.974179 74.722606) + (xy 164.9745 74.731595) + (xy 164.9745 76.629233) + (xy 164.973973 76.640416) + (xy 164.972298 76.647909) + (xy 164.972547 76.655835) + (xy 164.972547 76.655836) + (xy 164.974438 76.715986) + (xy 164.9745 76.719945) + (xy 164.9745 76.747856) + (xy 164.974997 76.75179) + (xy 164.974997 76.751791) + (xy 164.975005 76.751856) + (xy 164.975938 76.763693) + (xy 164.977327 76.807889) + (xy 164.982978 76.827339) + (xy 164.986987 76.8467) + (xy 164.989526 76.866797) + (xy 164.992445 76.874168) + (xy 164.992445 76.87417) + (xy 165.005804 76.907912) + (xy 165.009649 76.919142) + (xy 165.021982 76.961593) + (xy 165.026015 76.968412) + (xy 165.026017 76.968417) + (xy 165.032293 76.979028) + (xy 165.040988 76.996776) + (xy 165.048448 77.015617) + (xy 165.05311 77.022033) + (xy 165.05311 77.022034) + (xy 165.074436 77.051387) + (xy 165.080952 77.061307) + (xy 165.094071 77.083489) + (xy 165.103458 77.099362) + (xy 165.117779 77.113683) + (xy 165.130619 77.128716) + (xy 165.142528 77.145107) + (xy 165.148634 77.150158) + (xy 165.176605 77.173298) + (xy 165.185384 77.181288) + (xy 166.289777 78.285682) + (xy 166.323803 78.347994) + (xy 166.3221 78.408446) + (xy 166.300989 78.48457) + (xy 166.277251 78.706695) + (xy 166.277548 78.711848) + (xy 166.277548 78.711851) + (xy 166.287688 78.887717) + (xy 166.29011 78.929715) + (xy 166.291247 78.934761) + (xy 166.291248 78.934767) + (xy 166.314803 79.039283) + (xy 166.339222 79.147639) + (xy 166.423266 79.354616) + (xy 166.452513 79.402343) + (xy 166.498675 79.477672) + (xy 166.539987 79.545088) + (xy 166.68625 79.713938) + (xy 166.858126 79.856632) + (xy 166.91919 79.892315) + (xy 166.931445 79.899476) + (xy 166.980169 79.951114) + (xy 166.99324 80.020897) + (xy 166.966509 80.086669) + (xy 166.926055 80.120027) + (xy 166.913607 80.126507) + (xy 166.909474 80.12961) + (xy 166.909471 80.129612) + (xy 166.74247 80.255) + (xy 166.734965 80.260635) + (xy 166.713544 80.283051) + (xy 166.593667 80.408495) + (xy 166.580629 80.422138) + (xy 166.577715 80.42641) + (xy 166.577714 80.426411) + (xy 166.530027 80.496318) + (xy 166.454743 80.60668) + (xy 166.416011 80.690121) + (xy 166.37946 80.768865) + (xy 166.360688 80.809305) + (xy 166.300989 81.02457) + (xy 166.277251 81.246695) + (xy 166.277548 81.251848) + (xy 166.277548 81.251851) + (xy 166.285889 81.396507) + (xy 166.29011 81.469715) + (xy 166.291247 81.474761) + (xy 166.291248 81.474767) + (xy 166.311119 81.562939) + (xy 166.339222 81.687639) + (xy 166.341164 81.692422) + (xy 166.341167 81.692431) + (xy 166.36174 81.743095) + (xy 166.368837 81.813736) + (xy 166.336615 81.877) + (xy 166.275306 81.912801) + (xy 166.244998 81.9165) + (xy 158.057018 81.9165) + (xy 158.045835 81.915973) + (xy 158.038342 81.914298) + (xy 158.030416 81.914547) + (xy 158.030415 81.914547) + (xy 157.970252 81.916438) + (xy 157.966294 81.9165) + (xy 157.938395 81.9165) + (xy 157.934405 81.917004) + (xy 157.922571 81.917936) + (xy 157.878362 81.919326) + (xy 157.870748 81.921538) + (xy 157.870743 81.921539) + (xy 157.85891 81.924977) + (xy 157.839547 81.928988) + (xy 157.819454 81.931526) + (xy 157.807286 81.936343) + (xy 157.736589 81.942824) + (xy 157.673609 81.910053) + (xy 157.638343 81.848434) + (xy 157.64199 81.777531) + (xy 157.671808 81.730097) + (xy 164.759405 74.6425) + (xy 164.821717 74.608474) ) ) (filled_polygon @@ -10355,8 +10503,6 @@ (xy 142.94078 81.178909) (xy 143.000444 81.136351) (xy 143.11986 81.051173) - (xy 143.129415 81.041652) - (xy 143.274435 80.897137) (xy 143.278096 80.893489) (xy 143.28671 80.881502) (xy 143.408453 80.712077) @@ -10376,7 +10522,7 @@ (xy 130.740989 72.13457) (xy 130.740441 72.1397) (xy 130.74044 72.139704) - (xy 130.730654 72.231281) + (xy 130.731582 72.222595) (xy 130.717251 72.356695) (xy 130.717548 72.361848) (xy 130.717548 72.361851) @@ -10571,7 +10717,7 @@ (xy 136.988622 74.409593) (xy 136.977816 74.403652) (xy 136.961297 74.392801) - (xy 136.955364 74.388199) + (xy 136.960833 74.392441) (xy 136.945291 74.380386) (xy 136.938022 74.377241) (xy 136.938018 74.377238) @@ -10830,7 +10976,7 @@ (xy 130.717251 67.276695) (xy 130.717548 67.281848) (xy 130.717548 67.281851) - (xy 130.72526 67.415606) + (xy 130.724797 67.407564) (xy 130.73011 67.499715) (xy 130.731247 67.504761) (xy 130.731248 67.504767) @@ -10969,6 +11115,68 @@ (xy 133.36658 67.957625) ) ) + (filled_polygon + (layer "F.Cu") + (pts + (xy 148.429935 64.154662) + (xy 150.985101 65.858106) + (xy 151.030686 65.912535) + (xy 151.040495 65.976334) + (xy 151.0378 66.001552) + (xy 151.0378 66.00156) + (xy 151.037251 66.006695) + (xy 151.037548 66.011848) + (xy 151.037548 66.011851) + (xy 151.043417 66.113642) + (xy 151.05011 66.229715) + (xy 151.051247 66.234761) + (xy 151.051248 66.234767) + (xy 151.065436 66.297721) + (xy 151.099222 66.447639) + (xy 151.101164 66.452422) + (xy 151.101167 66.452431) + (xy 151.12174 66.503095) + (xy 151.128837 66.573736) + (xy 151.096615 66.637) + (xy 151.035306 66.672801) + (xy 151.004998 66.6765) + (xy 146.999595 66.6765) + (xy 146.931474 66.656498) + (xy 146.9105 66.639595) + (xy 145.937875 65.66697) + (xy 145.903849 65.604658) + (xy 145.908914 65.533843) + (xy 145.924647 65.504349) + (xy 145.945004 65.476019) + (xy 145.950315 65.46718) + (xy 146.04467 65.276267) + (xy 146.048469 65.266672) + (xy 146.110377 65.06291) + (xy 146.112555 65.052837) + (xy 146.113986 65.041962) + (xy 146.111775 65.027778) + (xy 146.098617 65.024) + (xy 144.652 65.024) + (xy 144.583879 65.003998) + (xy 144.537386 64.950342) + (xy 144.526 64.898) + (xy 144.526 64.642) + (xy 144.546002 64.573879) + (xy 144.599658 64.527386) + (xy 144.652 64.516) + (xy 146.098344 64.516) + (xy 146.111875 64.512027) + (xy 146.11318 64.502947) + (xy 146.071214 64.335875) + (xy 146.067894 64.326123) + (xy 146.060772 64.309744) + (xy 146.051951 64.239297) + (xy 146.082617 64.175265) + (xy 146.143033 64.137977) + (xy 146.176321 64.1335) + (xy 148.360043 64.1335) + ) + ) (filled_polygon (layer "F.Cu") (pts @@ -11110,68 +11318,6 @@ (xy 138.877406 64.1335) ) ) - (filled_polygon - (layer "F.Cu") - (pts - (xy 148.429935 64.154662) - (xy 150.985101 65.858106) - (xy 151.030686 65.912535) - (xy 151.040495 65.976334) - (xy 151.0378 66.001552) - (xy 151.0378 66.00156) - (xy 151.037251 66.006695) - (xy 151.037548 66.011848) - (xy 151.037548 66.011851) - (xy 151.043417 66.113642) - (xy 151.05011 66.229715) - (xy 151.051247 66.234761) - (xy 151.051248 66.234767) - (xy 151.065436 66.297721) - (xy 151.099222 66.447639) - (xy 151.101164 66.452422) - (xy 151.101167 66.452431) - (xy 151.12174 66.503095) - (xy 151.128837 66.573736) - (xy 151.096615 66.637) - (xy 151.035306 66.672801) - (xy 151.004998 66.6765) - (xy 146.999595 66.6765) - (xy 146.931474 66.656498) - (xy 146.9105 66.639595) - (xy 145.937875 65.66697) - (xy 145.903849 65.604658) - (xy 145.908914 65.533843) - (xy 145.924647 65.504349) - (xy 145.945004 65.476019) - (xy 145.950315 65.46718) - (xy 146.04467 65.276267) - (xy 146.048469 65.266672) - (xy 146.110377 65.06291) - (xy 146.112555 65.052837) - (xy 146.113986 65.041962) - (xy 146.111775 65.027778) - (xy 146.098617 65.024) - (xy 144.652 65.024) - (xy 144.583879 65.003998) - (xy 144.537386 64.950342) - (xy 144.526 64.898) - (xy 144.526 64.642) - (xy 144.546002 64.573879) - (xy 144.599658 64.527386) - (xy 144.652 64.516) - (xy 146.098344 64.516) - (xy 146.111875 64.512027) - (xy 146.11318 64.502947) - (xy 146.071214 64.335875) - (xy 146.067894 64.326123) - (xy 146.060772 64.309744) - (xy 146.051951 64.239297) - (xy 146.082617 64.175265) - (xy 146.143033 64.137977) - (xy 146.176321 64.1335) - (xy 148.360043 64.1335) - ) - ) (filled_polygon (layer "F.Cu") (pts @@ -11191,9 +11337,9 @@ (xy 144.053607 61.076507) (xy 144.049474 61.07961) (xy 144.049471 61.079612) - (xy 143.949374 61.154767) + (xy 143.8791 61.20753) (xy 143.874965 61.210635) - (xy 143.844095 61.242939) + (xy 143.871393 61.214373) (xy 143.725031 61.367532) (xy 143.720629 61.372138) (xy 143.613201 61.529621) @@ -11249,16 +11395,17 @@ (xy 141.139987 60.495088) (xy 141.28625 60.663938) (xy 141.458126 60.806632) - (xy 141.512657 60.838497) + (xy 141.528595 60.847811) (xy 141.531445 60.849476) (xy 141.580169 60.901114) (xy 141.59324 60.970897) (xy 141.566509 61.036669) (xy 141.526055 61.070027) + (xy 141.519766 61.073301) (xy 141.513607 61.076507) (xy 141.509474 61.07961) (xy 141.509471 61.079612) - (xy 141.409374 61.154767) + (xy 141.3391 61.20753) (xy 141.334965 61.210635) (xy 141.180629 61.372138) (xy 141.179727 61.371276) @@ -11279,7 +11426,7 @@ (xy 140.052321 60.439593) (xy 140.041515 60.433652) (xy 140.024996 60.422801) - (xy 140.024532 60.422441) + (xy 140.016751 60.416406) (xy 140.00899 60.410386) (xy 140.001721 60.407241) (xy 140.001717 60.407238) @@ -11366,7 +11513,7 @@ (xy 143.322822 56.322617) (xy 143.32282 56.322614) (xy 143.320014 56.318277) - (xy 143.316532 56.31445) + (xy 143.310842 56.308197) (xy 143.172798 56.156488) (xy 143.141746 56.092642) (xy 143.150141 56.022143) @@ -11376,7 +11523,7 @@ (xy 143.336705 55.910615) (xy 143.453261 55.823261) (xy 143.540615 55.706705) - (xy 143.550679 55.67986) + (xy 143.546172 55.691883) (xy 143.584798 55.588848) (xy 143.62744 55.532084) (xy 143.694001 55.507384) @@ -11499,25 +11646,25 @@ (filled_polygon (layer "B.Cu") (pts - (xy 171.543641 47.518502) - (xy 171.564615 47.535405) - (xy 172.448188 48.418978) - (xy 172.462132 48.426592) - (xy 172.463965 48.426461) - (xy 172.47058 48.42221) - (xy 173.357385 47.535405) - (xy 173.419697 47.501379) - (xy 173.44648 47.4985) - (xy 176.55552 47.4985) - (xy 176.623641 47.518502) - (xy 176.644615 47.535405) - (xy 177.528188 48.418978) - (xy 177.542132 48.426592) - (xy 177.543965 48.426461) - (xy 177.55058 48.42221) - (xy 178.437385 47.535405) - (xy 178.499697 47.501379) - (xy 178.52648 47.4985) + (xy 171.593641 47.518502) + (xy 171.614615 47.535405) + (xy 172.498188 48.418978) + (xy 172.512132 48.426592) + (xy 172.513965 48.426461) + (xy 172.52058 48.42221) + (xy 173.407385 47.535405) + (xy 173.469697 47.501379) + (xy 173.49648 47.4985) + (xy 176.60552 47.4985) + (xy 176.673641 47.518502) + (xy 176.694615 47.535405) + (xy 177.578188 48.418978) + (xy 177.592132 48.426592) + (xy 177.593965 48.426461) + (xy 177.60058 48.42221) + (xy 178.487385 47.535405) + (xy 178.549697 47.501379) + (xy 178.57648 47.4985) (xy 179.401633 47.4985) (xy 179.421018 47.5) (xy 179.435852 47.50231) @@ -11690,7 +11837,7 @@ (xy 181.027014 93.496009) (xy 181.023411 93.498706) (xy 181.023405 93.49871) - (xy 180.943005 93.558897) + (xy 180.941478 93.56004) (xy 180.823355 93.648466) (xy 180.643466 93.828355) (xy 180.640769 93.831958) @@ -11699,11 +11846,11 @@ (xy 180.491009 94.032014) (xy 180.369087 94.255297) (xy 180.367516 94.259509) - (xy 180.284053 94.483284) + (xy 180.289522 94.468621) (xy 180.280183 94.493659) (xy 180.279228 94.49805) (xy 180.279226 94.498056) - (xy 180.247587 94.6435) + (xy 180.254921 94.609787) (xy 180.226106 94.742247) (xy 180.225785 94.746735) (xy 180.209711 94.971477) @@ -11749,26 +11896,26 @@ (xy 179.435856 101.85111) (xy 179.425714 101.852436) (xy 179.409379 101.8535) - (xy 178.52648 101.8535) - (xy 178.458359 101.833498) - (xy 178.437385 101.816595) - (xy 177.553812 100.933022) - (xy 177.539868 100.925408) - (xy 177.538035 100.925539) - (xy 177.53142 100.92979) - (xy 176.644615 101.816595) - (xy 176.582303 101.850621) - (xy 176.55552 101.8535) - (xy 173.44648 101.8535) - (xy 173.378359 101.833498) - (xy 173.357385 101.816595) - (xy 172.473812 100.933022) - (xy 172.459868 100.925408) - (xy 172.458035 100.925539) - (xy 172.45142 100.92979) - (xy 171.564615 101.816595) - (xy 171.502303 101.850621) - (xy 171.47552 101.8535) + (xy 178.57648 101.8535) + (xy 178.508359 101.833498) + (xy 178.487385 101.816595) + (xy 177.603812 100.933022) + (xy 177.589868 100.925408) + (xy 177.588035 100.925539) + (xy 177.58142 100.92979) + (xy 176.694615 101.816595) + (xy 176.632303 101.850621) + (xy 176.60552 101.8535) + (xy 173.49648 101.8535) + (xy 173.428359 101.833498) + (xy 173.407385 101.816595) + (xy 172.523812 100.933022) + (xy 172.509868 100.925408) + (xy 172.508035 100.925539) + (xy 172.50142 100.92979) + (xy 171.614615 101.816595) + (xy 171.552303 101.850621) + (xy 171.52552 101.8535) (xy 126.414367 101.8535) (xy 126.394982 101.852) (xy 126.380148 101.84969) @@ -11811,7 +11958,7 @@ (xy 128.249584 100.471607) (xy 128.251975 100.4762) (xy 128.255085 100.480342) - (xy 128.390574 100.660796) + (xy 128.380444 100.647304) (xy 128.396223 100.66832) (xy 128.569912 100.834301) (xy 128.768378 100.969686) @@ -11840,11 +11987,11 @@ (xy 130.280263 100.986997) (xy 130.481977 100.856502) (xy 130.65967 100.694814) - (xy 130.752434 100.577354) + (xy 130.738623 100.594842) (xy 130.805367 100.51033) (xy 130.80537 100.510325) (xy 130.808568 100.506276) - (xy 130.822885 100.480342) + (xy 130.812541 100.49908) (xy 130.922177 100.300474) (xy 130.922179 100.30047) (xy 130.924674 100.29595) @@ -11858,7 +12005,7 @@ (xy 131.047001 99.832963) (xy 131.049936 99.592737) (xy 131.013596 99.355256) - (xy 130.971149 99.225388) + (xy 130.955822 99.178494) (xy 130.940566 99.131817) (xy 130.940563 99.131811) (xy 130.938958 99.126899) @@ -11953,12 +12100,12 @@ (xy 131.046095 97.298052) (xy 131.046096 97.298046) (xy 131.047001 97.292963) - (xy 131.048997 97.129603) + (xy 131.049738 97.068971) (xy 131.049873 97.057907) (xy 131.049873 97.057905) (xy 131.049936 97.052737) (xy 131.013596 96.815256) - (xy 130.952464 96.628221) + (xy 130.961982 96.657342) (xy 130.940566 96.591817) (xy 130.940563 96.591811) (xy 130.938958 96.586899) @@ -11973,13 +12120,14 @@ (xy 130.778293 96.021269) (xy 130.778296 96.021267) (xy 130.786705 96.018115) - (xy 130.892702 95.938674) - (xy 130.959209 95.913826) - (xy 130.968268 95.9135) - (xy 132.6275 95.9135) - (xy 132.695621 95.933502) - (xy 132.742114 95.987158) - (xy 132.7535 96.0395) + (xy 130.852774 95.968599) + (xy 130.866017 95.958674) + (xy 130.932523 95.933826) + (xy 130.941582 95.9335) + (xy 132.6275 95.9335) + (xy 132.695621 95.953502) + (xy 132.742114 96.007158) + (xy 132.7535 96.0595) (xy 132.7535 96.783134) (xy 132.760255 96.845316) (xy 132.811385 96.981705) @@ -12024,16 +12172,15 @@ (xy 135.4705 94.986866) (xy 135.463745 94.924684) (xy 135.412615 94.788295) - (xy 135.325261 94.671739) - (xy 135.319867 94.667696) - (xy 135.286379 94.60637) - (xy 135.2835 94.579587) - (xy 135.2835 92.27502) - (xy 135.303502 92.206899) - (xy 135.320405 92.185925) - (xy 135.615925 91.890405) - (xy 135.678237 91.856379) - (xy 135.70502 91.8535) + (xy 135.328674 94.676293) + (xy 135.303826 94.609787) + (xy 135.3035 94.600728) + (xy 135.3035 92.283305) + (xy 135.323502 92.215184) + (xy 135.340405 92.19421) + (xy 135.64421 91.890405) + (xy 135.706522 91.856379) + (xy 135.733305 91.8535) (xy 136.0854 91.8535) (xy 136.088646 91.853163) (xy 136.08865 91.853163) @@ -12046,11 +12193,11 @@ (xy 136.358946 91.78655) (xy 136.509348 91.693478) (xy 136.634305 91.568303) - (xy 136.692653 91.473645) + (xy 136.680413 91.493503) (xy 136.723275 91.423968) (xy 136.723276 91.423966) (xy 136.727115 91.417738) - (xy 136.760807 91.316158) + (xy 136.766759 91.298214) (xy 136.780632 91.256389) (xy 136.780632 91.256387) (xy 136.782797 91.249861) @@ -12227,58 +12374,56 @@ (xy 134.2765 91.1454) (xy 134.276837 91.148646) (xy 134.276837 91.14865) - (xy 134.282528 91.203495) - (xy 134.287474 91.251166) - (xy 134.289658 91.257711) - (xy 134.289777 91.258264) - (xy 134.284606 91.329072) - (xy 134.255711 91.373958) - (xy 134.170179 91.45949) - (xy 134.163914 91.465343) - (xy 134.123302 91.500771) - (xy 134.089023 91.549546) - (xy 134.08509 91.554841) - (xy 134.054178 91.594265) - (xy 134.048298 91.601764) - (xy 134.045174 91.608683) - (xy 134.041573 91.614629) - (xy 134.038632 91.619786) - (xy 134.03533 91.625944) - (xy 134.030961 91.63216) - (xy 134.028202 91.639236) - (xy 134.028201 91.639238) - (xy 134.009308 91.687696) - (xy 134.006752 91.693777) - (xy 133.988243 91.73477) - (xy 133.982211 91.748129) - (xy 133.980827 91.755595) - (xy 133.978753 91.762214) - (xy 133.977115 91.767963) - (xy 133.975385 91.774704) - (xy 133.972625 91.781782) - (xy 133.971633 91.789318) - (xy 133.964844 91.840888) - (xy 133.963812 91.847405) - (xy 133.963308 91.850123) - (xy 133.952946 91.906033) - (xy 133.953383 91.913613) - (xy 133.953383 91.913614) - (xy 133.956291 91.964047) - (xy 133.9565 91.9713) - (xy 133.9565 94.4005) - (xy 133.936498 94.468621) - (xy 133.882842 94.515114) - (xy 133.8305 94.5265) + (xy 134.279788 91.177091) + (xy 134.287181 91.248339) + (xy 134.274317 91.318158) + (xy 134.250949 91.350436) + (xy 134.156541 91.444844) + (xy 134.150276 91.450698) + (xy 134.10833 91.48729) + (xy 134.072934 91.537655) + (xy 134.069022 91.54292) + (xy 134.031065 91.591328) + (xy 134.027939 91.598252) + (xy 134.025329 91.602561) + (xy 134.019958 91.611976) + (xy 134.017573 91.616424) + (xy 134.013205 91.622639) + (xy 134.010446 91.629716) + (xy 133.990858 91.679957) + (xy 133.988306 91.686029) + (xy 133.962986 91.742105) + (xy 133.9616 91.749582) + (xy 133.96009 91.754402) + (xy 133.957118 91.764835) + (xy 133.95587 91.769696) + (xy 133.953111 91.776772) + (xy 133.95212 91.784302) + (xy 133.945082 91.837762) + (xy 133.94405 91.844278) + (xy 133.942403 91.853163) + (xy 133.932839 91.904767) + (xy 133.933276 91.912347) + (xy 133.933276 91.912348) + (xy 133.936291 91.964642) + (xy 133.9365 91.971894) + (xy 133.9365 94.4005) + (xy 133.916498 94.468621) + (xy 133.862842 94.515114) + (xy 133.8105 94.5265) (xy 133.213866 94.5265) + (xy 133.210469 94.526869) + (xy 133.159534 94.532402) + (xy 133.159532 94.532402) (xy 133.151684 94.533255) - (xy 133.144288 94.536027) - (xy 133.144282 94.536029) - (xy 133.03104 94.578482) - (xy 132.986811 94.5865) - (xy 131.1745 94.5865) - (xy 131.106379 94.566498) - (xy 131.059886 94.512842) - (xy 131.0485 94.4605) + (xy 133.144291 94.536027) + (xy 133.144289 94.536027) + (xy 133.084391 94.558482) + (xy 133.040162 94.5665) + (xy 131.1745 94.5665) + (xy 131.106379 94.546498) + (xy 131.059886 94.492842) + (xy 131.0485 94.4405) (xy 131.0485 93.614366) (xy 131.041745 93.552184) (xy 130.990615 93.415795) @@ -12308,17 +12453,17 @@ (xy 128.271432 96.343724) (xy 128.268939 96.34824) (xy 128.268937 96.348243) - (xy 128.158401 96.548479) + (xy 128.172265 96.523365) (xy 128.155326 96.55405) (xy 128.153602 96.558919) (xy 128.1536 96.558923) - (xy 128.085925 96.75003) + (xy 128.083825 96.755961) (xy 128.07513 96.780515) (xy 128.074223 96.785608) (xy 128.074222 96.785611) - (xy 128.037235 96.993259) + (xy 128.035299 97.004126) (xy 128.032999 97.017037) - (xy 128.032936 97.022201) + (xy 128.032279 97.075985) (xy 128.030244 97.242564) (xy 128.030064 97.257263) (xy 128.066404 97.494744) @@ -12365,124 +12510,124 @@ (xy 128.030064 99.797263) (xy 125.6035 99.797263) (xy 125.6035 88.739695) - (xy 128.177251 88.739695) - (xy 128.177548 88.744848) - (xy 128.177548 88.744851) - (xy 128.188121 88.928216) - (xy 128.19011 88.962715) - (xy 128.191247 88.967761) - (xy 128.191248 88.967767) - (xy 128.211119 89.055939) - (xy 128.239222 89.180639) - (xy 128.277461 89.274811) - (xy 128.311363 89.358301) - (xy 128.323266 89.387616) - (xy 128.361234 89.449574) - (xy 128.43386 89.568089) - (xy 128.439987 89.578088) - (xy 128.58625 89.746938) - (xy 128.59023 89.750242) - (xy 128.594981 89.754187) - (xy 128.634616 89.81309) - (xy 128.636113 89.884071) - (xy 128.598997 89.944593) - (xy 128.558725 89.969112) - (xy 128.499238 89.991413) - (xy 128.443295 90.012385) - (xy 128.326739 90.099739) - (xy 128.239385 90.216295) - (xy 128.188255 90.352684) - (xy 128.1815 90.414866) - (xy 128.1815 92.211134) - (xy 128.188255 92.273316) - (xy 128.239385 92.409705) - (xy 128.326739 92.526261) - (xy 128.443295 92.613615) - (xy 128.579684 92.664745) - (xy 128.63556 92.670815) - (xy 128.637678 92.671045) - (xy 128.641866 92.6715) - (xy 130.438134 92.6715) - (xy 130.442323 92.671045) - (xy 130.44444 92.670815) - (xy 130.500316 92.664745) - (xy 130.636705 92.613615) - (xy 130.753261 92.526261) - (xy 130.840615 92.409705) - (xy 130.891745 92.273316) - (xy 130.8985 92.211134) - (xy 130.8985 90.414866) - (xy 130.891745 90.352684) - (xy 130.840615 90.216295) - (xy 130.753261 90.099739) - (xy 130.636705 90.012385) - (xy 130.624132 90.007672) - (xy 130.518203 89.96796) - (xy 130.461439 89.925318) - (xy 130.436739 89.858756) - (xy 130.451947 89.789408) - (xy 130.473493 89.760727) - (xy 130.491251 89.743031) - (xy 130.578096 89.656489) - (xy 130.628198 89.586765) - (xy 130.705435 89.479277) - (xy 130.708453 89.475077) - (xy 130.711881 89.468142) - (xy 130.805136 89.279453) - (xy 130.805137 89.279451) - (xy 130.80743 89.274811) - (xy 130.859286 89.104134) - (xy 130.870865 89.066023) - (xy 130.870865 89.066021) - (xy 130.87237 89.061069) - (xy 130.901529 88.83959) - (xy 130.901667 88.833946) - (xy 130.903074 88.776365) - (xy 130.903074 88.776361) - (xy 130.903156 88.773) - (xy 130.884852 88.550361) - (xy 130.830431 88.333702) - (xy 130.741354 88.12884) - (xy 130.620014 87.941277) - (xy 130.46967 87.776051) - (xy 130.465619 87.772852) - (xy 130.465615 87.772848) - (xy 130.298414 87.6408) - (xy 130.29841 87.640798) - (xy 130.294359 87.637598) - (xy 130.283851 87.631797) - (xy 130.201733 87.586466) - (xy 130.098789 87.529638) - (xy 130.09392 87.527914) - (xy 130.093916 87.527912) - (xy 129.893087 87.456795) - (xy 129.893083 87.456794) - (xy 129.888212 87.455069) - (xy 129.883119 87.454162) - (xy 129.883116 87.454161) - (xy 129.673373 87.4168) - (xy 129.673367 87.416799) - (xy 129.668284 87.415894) - (xy 129.594452 87.414992) - (xy 129.450081 87.413228) - (xy 129.450079 87.413228) - (xy 129.444911 87.413165) - (xy 129.224091 87.446955) - (xy 129.011756 87.516357) - (xy 128.981443 87.532137) - (xy 128.841208 87.605139) - (xy 128.813607 87.619507) - (xy 128.809474 87.62261) - (xy 128.809471 87.622612) - (xy 128.689264 87.712866) - (xy 128.634965 87.753635) - (xy 128.480629 87.915138) - (xy 128.354743 88.09968) - (xy 128.310815 88.194316) - (xy 128.278701 88.2635) - (xy 128.260688 88.302305) - (xy 128.200989 88.51757) - (xy 128.177251 88.739695) + (xy 126.526251 88.739695) + (xy 126.526548 88.744848) + (xy 126.526548 88.744851) + (xy 126.537121 88.928216) + (xy 126.53911 88.962715) + (xy 126.540247 88.967761) + (xy 126.540248 88.967767) + (xy 126.560119 89.055939) + (xy 126.588222 89.180639) + (xy 126.626461 89.274811) + (xy 126.660363 89.358301) + (xy 126.672266 89.387616) + (xy 126.710234 89.449574) + (xy 126.78286 89.568089) + (xy 126.788987 89.578088) + (xy 126.93525 89.746938) + (xy 126.93923 89.750242) + (xy 126.943981 89.754187) + (xy 126.983616 89.81309) + (xy 126.985113 89.884071) + (xy 126.947997 89.944593) + (xy 126.907725 89.969112) + (xy 126.848238 89.991413) + (xy 126.792295 90.012385) + (xy 126.675739 90.099739) + (xy 126.588385 90.216295) + (xy 126.537255 90.352684) + (xy 126.5305 90.414866) + (xy 126.5305 92.211134) + (xy 126.537255 92.273316) + (xy 126.588385 92.409705) + (xy 126.675739 92.526261) + (xy 126.792295 92.613615) + (xy 126.928684 92.664745) + (xy 126.98456 92.670815) + (xy 126.986678 92.671045) + (xy 126.990866 92.6715) + (xy 128.787134 92.6715) + (xy 128.791323 92.671045) + (xy 128.79344 92.670815) + (xy 128.849316 92.664745) + (xy 128.985705 92.613615) + (xy 129.102261 92.526261) + (xy 129.189615 92.409705) + (xy 129.240745 92.273316) + (xy 129.2475 92.211134) + (xy 129.2475 90.414866) + (xy 129.240745 90.352684) + (xy 129.189615 90.216295) + (xy 129.102261 90.099739) + (xy 128.985705 90.012385) + (xy 128.973132 90.007672) + (xy 128.867203 89.96796) + (xy 128.810439 89.925318) + (xy 128.785739 89.858756) + (xy 128.800947 89.789408) + (xy 128.822493 89.760727) + (xy 128.923435 89.660137) + (xy 128.927096 89.656489) + (xy 128.977198 89.586765) + (xy 129.054435 89.479277) + (xy 129.057453 89.475077) + (xy 129.060881 89.468142) + (xy 129.154136 89.279453) + (xy 129.154137 89.279451) + (xy 129.15643 89.274811) + (xy 129.208286 89.104134) + (xy 129.219865 89.066023) + (xy 129.219865 89.066021) + (xy 129.22137 89.061069) + (xy 129.250529 88.83959) + (xy 129.250667 88.833946) + (xy 129.252074 88.776365) + (xy 129.252074 88.776361) + (xy 129.252156 88.773) + (xy 129.233852 88.550361) + (xy 129.179431 88.333702) + (xy 129.090354 88.12884) + (xy 128.969014 87.941277) + (xy 128.81867 87.776051) + (xy 128.814619 87.772852) + (xy 128.814615 87.772848) + (xy 128.647414 87.6408) + (xy 128.64741 87.640798) + (xy 128.643359 87.637598) + (xy 128.632851 87.631797) + (xy 128.550733 87.586466) + (xy 128.447789 87.529638) + (xy 128.44292 87.527914) + (xy 128.442916 87.527912) + (xy 128.242087 87.456795) + (xy 128.242083 87.456794) + (xy 128.237212 87.455069) + (xy 128.232119 87.454162) + (xy 128.232116 87.454161) + (xy 128.022373 87.4168) + (xy 128.022367 87.416799) + (xy 128.017284 87.415894) + (xy 127.943452 87.414992) + (xy 127.799081 87.413228) + (xy 127.799079 87.413228) + (xy 127.793911 87.413165) + (xy 127.573091 87.446955) + (xy 127.360756 87.516357) + (xy 127.330443 87.532137) + (xy 127.190208 87.605139) + (xy 127.162607 87.619507) + (xy 127.158474 87.62261) + (xy 127.158471 87.622612) + (xy 127.038264 87.712866) + (xy 126.983965 87.753635) + (xy 126.829629 87.915138) + (xy 126.703743 88.09968) + (xy 126.659815 88.194316) + (xy 126.627701 88.2635) + (xy 126.609688 88.302305) + (xy 126.549989 88.51757) + (xy 126.526251 88.739695) (xy 125.6035 88.739695) (xy 125.6035 82.832833) (xy 125.623502 82.764712) @@ -12495,15 +12640,15 @@ (xy 129.190615 82.445038) (xy 129.241745 82.308649) (xy 129.2485 82.246467) - (xy 129.2485 82.0645) - (xy 129.268502 81.996379) - (xy 129.322158 81.949886) - (xy 129.3745 81.9385) - (xy 130.674039 81.9385) - (xy 130.74216 81.958502) - (xy 130.788653 82.012158) - (xy 130.798757 82.082432) - (xy 130.795458 82.098164) + (xy 129.2485 82.1095) + (xy 129.268502 82.041379) + (xy 129.322158 81.994886) + (xy 129.3745 81.9835) + (xy 130.661559 81.9835) + (xy 130.72968 82.003502) + (xy 130.776173 82.057158) + (xy 130.786277 82.127432) + (xy 130.782976 82.14317) (xy 130.740989 82.29457) (xy 130.717251 82.516695) (xy 130.717548 82.521848) @@ -12537,6 +12682,8 @@ (xy 131.029748 84.222596) (xy 131.020629 84.232138) (xy 130.894743 84.41668) + (xy 130.879003 84.45059) + (xy 130.808973 84.601457) (xy 130.800688 84.619305) (xy 130.740989 84.83457) (xy 130.717251 85.056695) @@ -12560,7 +12707,7 @@ (xy 131.699692 86.39903) (xy 131.70476 86.400061) (xy 131.704763 86.400062) - (xy 131.766965 86.412717) + (xy 131.788302 86.417058) (xy 131.918597 86.443567) (xy 131.923772 86.443757) (xy 131.923774 86.443757) @@ -12596,7 +12743,7 @@ (xy 134.239692 86.39903) (xy 134.24476 86.400061) (xy 134.244763 86.400062) - (xy 134.306965 86.412717) + (xy 134.328302 86.417058) (xy 134.458597 86.443567) (xy 134.463772 86.443757) (xy 134.463774 86.443757) @@ -12626,7 +12773,7 @@ (xy 135.88743 85.591811) (xy 135.95237 85.378069) (xy 135.981529 85.15659) - (xy 135.982457 85.118601) + (xy 135.982403 85.120827) (xy 135.983074 85.093365) (xy 135.983074 85.093361) (xy 135.983156 85.09) @@ -12807,7 +12954,7 @@ (xy 141.859692 86.39903) (xy 141.86476 86.400061) (xy 141.864763 86.400062) - (xy 141.926965 86.412717) + (xy 141.948302 86.417058) (xy 142.078597 86.443567) (xy 142.083772 86.443757) (xy 142.083774 86.443757) @@ -12821,15 +12968,15 @@ (xy 142.523416 86.423368) (xy 142.528373 86.421881) (xy 142.528377 86.42188) - (xy 142.684292 86.375103) - (xy 142.755287 86.374685) - (xy 142.815238 86.412717) - (xy 142.84511 86.477124) - (xy 142.8465 86.495788) - (xy 142.8465 86.8755) - (xy 142.826498 86.943621) - (xy 142.772842 86.990114) - (xy 142.7205 87.0015) + (xy 142.639292 86.388604) + (xy 142.710287 86.388186) + (xy 142.770238 86.426219) + (xy 142.80011 86.490625) + (xy 142.8015 86.509289) + (xy 142.8015 86.8755) + (xy 142.781498 86.943621) + (xy 142.727842 86.990114) + (xy 142.6755 87.0015) (xy 142.3846 87.0015) (xy 142.381354 87.001837) (xy 142.38135 87.001837) @@ -12870,7 +13017,7 @@ (xy 141.967928 89.113146) (xy 142.105369 89.197866) (xy 142.112262 89.202115) - (xy 142.13772 89.210559) + (xy 142.16382 89.219216) (xy 142.273611 89.255632) (xy 142.273613 89.255632) (xy 142.280139 89.257797) @@ -12920,20 +13067,21 @@ (xy 144.733022 87.011502) (xy 144.689969 87.007091) (xy 144.6354 87.0015) - (xy 144.2995 87.0015) - (xy 144.231379 86.981498) - (xy 144.184886 86.927842) - (xy 144.1735 86.8755) - (xy 144.1735 86.495645) - (xy 144.193502 86.427524) - (xy 144.247158 86.381031) - (xy 144.317432 86.370927) - (xy 144.344449 86.377935) - (xy 144.352557 86.381031) + (xy 144.3445 87.0015) + (xy 144.276379 86.981498) + (xy 144.229886 86.927842) + (xy 144.2185 86.8755) + (xy 144.2185 86.512829) + (xy 144.238502 86.444708) + (xy 144.292158 86.398215) + (xy 144.362432 86.388111) + (xy 144.389445 86.395118) + (xy 144.394853 86.397183) + (xy 144.39486 86.397185) (xy 144.399692 86.39903) (xy 144.40476 86.400061) (xy 144.404763 86.400062) - (xy 144.466965 86.412717) + (xy 144.488302 86.417058) (xy 144.618597 86.443567) (xy 144.623772 86.443757) (xy 144.623774 86.443757) @@ -12963,7 +13111,7 @@ (xy 146.04743 85.591811) (xy 146.11237 85.378069) (xy 146.141529 85.15659) - (xy 146.142457 85.118601) + (xy 146.142403 85.120827) (xy 146.143074 85.093365) (xy 146.143074 85.093361) (xy 146.143156 85.09) @@ -13096,6 +13244,9 @@ (xy 146.045136 75.436453) (xy 146.045137 75.436451) (xy 146.04743 75.431811) + (xy 146.088967 75.295096) + (xy 146.110865 75.223023) + (xy 146.110865 75.223021) (xy 146.11237 75.218069) (xy 146.141529 74.99659) (xy 146.142676 74.949654) @@ -13148,55 +13299,51 @@ (xy 151.083803 91.047994) (xy 151.0821 91.108446) (xy 151.060989 91.18457) - (xy 151.06044 91.189704) - (xy 151.06044 91.189706) - (xy 151.058696 91.206026) - (xy 151.040689 91.37453) - (xy 151.038976 91.390557) - (xy 151.011848 91.456167) - (xy 150.953556 91.496695) - (xy 150.882606 91.499274) - (xy 150.824594 91.466263) - (xy 150.348509 90.990178) - (xy 150.342655 90.983912) - (xy 150.312225 90.949029) - (xy 150.307229 90.943302) - (xy 150.258443 90.909015) - (xy 150.253159 90.90509) - (xy 150.212211 90.872983) - (xy 150.206236 90.868298) - (xy 150.199317 90.865174) - (xy 150.193371 90.861573) - (xy 150.188214 90.858632) - (xy 150.182056 90.85533) - (xy 150.17584 90.850961) - (xy 150.168764 90.848202) - (xy 150.168762 90.848201) - (xy 150.120304 90.829308) - (xy 150.114223 90.826752) - (xy 150.06679 90.805335) - (xy 150.066789 90.805335) - (xy 150.059871 90.802211) - (xy 150.052405 90.800827) - (xy 150.045786 90.798753) - (xy 150.040037 90.797115) - (xy 150.033296 90.795385) - (xy 150.026218 90.792625) - (xy 150.002557 90.78951) - (xy 149.967112 90.784844) - (xy 149.960595 90.783812) - (xy 149.926669 90.777524) - (xy 149.901967 90.772946) - (xy 149.894387 90.773383) - (xy 149.894386 90.773383) - (xy 149.843953 90.776291) - (xy 149.8367 90.7765) - (xy 145.4695 90.7765) - (xy 145.401379 90.756498) - (xy 145.354886 90.702842) - (xy 145.3435 90.6505) + (xy 151.06044 91.189707) + (xy 151.04512 91.333062) + (xy 151.017992 91.398672) + (xy 150.9597 91.4392) + (xy 150.88875 91.441779) + (xy 150.830738 91.408768) + (xy 150.38145 90.95948) + (xy 150.375596 90.953215) + (xy 150.363849 90.939749) + (xy 150.337561 90.909615) + (xy 150.28528 90.872871) + (xy 150.279986 90.868939) + (xy 150.235693 90.834209) + (xy 150.229718 90.829524) + (xy 150.222802 90.826401) + (xy 150.220516 90.825017) + (xy 150.205835 90.816643) + (xy 150.203475 90.815378) + (xy 150.197261 90.81101) + (xy 150.190182 90.80825) + (xy 150.19018 90.808249) + (xy 150.137725 90.787798) + (xy 150.131656 90.785247) + (xy 150.073427 90.758955) + (xy 150.06596 90.757571) + (xy 150.063405 90.75677) + (xy 150.047152 90.752141) + (xy 150.044572 90.751478) + (xy 150.037491 90.748718) + (xy 150.02996 90.747727) + (xy 150.029958 90.747726) + (xy 149.99718 90.743411) + (xy 149.974139 90.740378) + (xy 149.967641 90.739348) + (xy 149.904814 90.727704) + (xy 149.897234 90.728141) + (xy 149.897233 90.728141) + (xy 149.842608 90.731291) + (xy 149.835354 90.7315) + (xy 145.4695 90.7315) + (xy 145.401379 90.711498) + (xy 145.354886 90.657842) + (xy 145.3435 90.6055) (xy 145.3435 90.5096) - (xy 145.338512 90.461526) + (xy 145.339031 90.466526) (xy 145.333238 90.410692) (xy 145.333237 90.410688) (xy 145.332526 90.403834) @@ -13243,17 +13390,17 @@ (xy 141.6765 91.3604) (xy 141.676837 91.363646) (xy 141.676837 91.36365) - (xy 141.686437 91.456167) + (xy 141.686159 91.453489) (xy 141.687474 91.466166) (xy 141.689655 91.472702) (xy 141.689655 91.472704) - (xy 141.715292 91.549546) + (xy 141.696594 91.493503) (xy 141.74345 91.633946) (xy 141.836522 91.784348) (xy 141.961697 91.909305) (xy 141.967927 91.913145) (xy 141.967928 91.913146) - (xy 142.050505 91.964047) + (xy 142.097652 91.993109) (xy 142.112262 92.002115) (xy 142.138022 92.010659) (xy 142.273611 92.055632) @@ -13261,47 +13408,48 @@ (xy 142.280139 92.057797) (xy 142.286975 92.058497) (xy 142.286978 92.058498) - (xy 142.328285 92.06273) + (xy 142.330031 92.062909) (xy 142.3846 92.0685) - (xy 144.534258 92.0685) - (xy 144.571937 92.074266) - (xy 144.57321 92.074665) - (xy 144.580129 92.077789) - (xy 144.587595 92.079173) - (xy 144.594214 92.081247) - (xy 144.599963 92.082885) - (xy 144.606704 92.084615) - (xy 144.613782 92.087375) - (xy 144.621318 92.088367) - (xy 144.672888 92.095156) - (xy 144.679405 92.096188) - (xy 144.713331 92.102476) - (xy 144.738033 92.107054) - (xy 144.745613 92.106617) - (xy 144.745614 92.106617) - (xy 144.796048 92.103709) - (xy 144.803301 92.1035) - (xy 149.53298 92.1035) - (xy 149.601101 92.123502) - (xy 149.622075 92.140405) - (xy 151.040566 93.558897) - (xy 151.074592 93.621209) - (xy 151.072888 93.681664) + (xy 144.417788 92.0685) + (xy 144.463558 92.077107) + (xy 144.502274 92.092202) + (xy 144.508352 92.094757) + (xy 144.566574 92.121045) + (xy 144.574045 92.122429) + (xy 144.576599 92.12323) + (xy 144.592878 92.127867) + (xy 144.595433 92.128523) + (xy 144.602509 92.131282) + (xy 144.627774 92.134608) + (xy 144.665851 92.139621) + (xy 144.672367 92.140653) + (xy 144.714706 92.1485) + (xy 144.735187 92.152296) + (xy 144.742767 92.151859) + (xy 144.742768 92.151859) + (xy 144.797398 92.148709) + (xy 144.804651 92.1485) + (xy 149.51434 92.1485) + (xy 149.582461 92.168502) + (xy 149.603435 92.185405) + (xy 151.027251 93.609222) + (xy 151.061277 93.671534) + (xy 151.061915 93.721231) (xy 151.060989 93.72457) (xy 151.037251 93.946695) (xy 151.037548 93.951848) (xy 151.037548 93.951851) - (xy 151.049812 94.164547) + (xy 151.049636 94.1615) (xy 151.05011 94.169715) (xy 151.051247 94.174761) (xy 151.051248 94.174767) (xy 151.068507 94.251347) (xy 151.099222 94.387639) - (xy 151.149471 94.511389) + (xy 151.150984 94.515114) (xy 151.179847 94.586195) (xy 151.183266 94.594616) - (xy 151.185965 94.59902) - (xy 151.260177 94.720123) + (xy 151.192563 94.609787) + (xy 151.285936 94.762158) (xy 151.299987 94.785088) (xy 151.44625 94.953938) (xy 151.618126 95.096632) @@ -13329,69 +13477,27 @@ (xy 153.047859 95.242245) (xy 153.072975 95.175839) (xy 153.100327 95.149232) - (xy 153.148132 95.115133) + (xy 153.156761 95.108978) (xy 153.27986 95.021173) - (xy 153.290571 95.0105) + (xy 153.332441 94.968776) (xy 153.390402 94.911017) (xy 153.438096 94.863489) - (xy 153.497594 94.780689) - (xy 153.558467 94.695974) - (xy 153.614462 94.652326) - (xy 153.66079 94.6435) - (xy 155.835052 94.6435) - (xy 155.903173 94.663502) - (xy 155.942195 94.703196) - (xy 155.956522 94.726348) - (xy 156.081697 94.851305) - (xy 156.087927 94.855145) - (xy 156.097816 94.861241) - (xy 156.145308 94.914014) - (xy 156.15673 94.984086) - (xy 156.128456 95.049209) - (xy 156.069461 95.088708) - (xy 156.031698 95.0945) - (xy 155.729349 95.0945) - (xy 155.720779 95.094208) - (xy 155.674596 95.091059) - (xy 155.674592 95.091059) - (xy 155.66702 95.090543) - (xy 155.608258 95.100798) - (xy 155.601766 95.101756) - (xy 155.573277 95.105204) - (xy 155.550113 95.108007) - (xy 155.550111 95.108008) - (xy 155.542571 95.10892) - (xy 155.535471 95.111603) - (xy 155.528728 95.113259) - (xy 155.522948 95.114841) - (xy 155.516296 95.116849) - (xy 155.508819 95.118154) - (xy 155.501874 95.121203) - (xy 155.501866 95.121205) - (xy 155.454232 95.142115) - (xy 155.448126 95.144607) - (xy 155.431512 95.150885) - (xy 155.392345 95.165685) - (xy 155.386086 95.169987) - (xy 155.379932 95.173204) - (xy 155.374723 95.176103) - (xy 155.368723 95.179651) - (xy 155.361771 95.182703) - (xy 155.355747 95.187326) - (xy 155.355741 95.187329) - (xy 155.314475 95.218994) - (xy 155.309152 95.222862) - (xy 155.259997 95.256646) - (xy 155.254945 95.262316) - (xy 155.254944 95.262317) - (xy 155.221328 95.300047) - (xy 155.216347 95.305323) - (xy 153.97319 96.548479) - (xy 153.910878 96.582505) - (xy 153.840062 96.57744) - (xy 153.783227 96.534893) - (xy 153.758519 96.469708) - (xy 153.744781 96.302603) + (xy 153.460413 94.832432) + (xy 153.526132 94.740974) + (xy 153.582127 94.697326) + (xy 153.628455 94.6885) + (xy 155.536051 94.6885) + (xy 155.604172 94.708502) + (xy 155.650665 94.762158) + (xy 155.660769 94.832432) + (xy 155.631275 94.897012) + (xy 155.625146 94.903595) + (xy 153.973728 96.555013) + (xy 153.911416 96.589039) + (xy 153.840601 96.583974) + (xy 153.783765 96.541427) + (xy 153.759057 96.476242) + (xy 153.744781 96.302604) (xy 153.743096 96.292424) (xy 153.691214 96.085875) (xy 153.687894 96.076124) @@ -13424,20 +13530,21 @@ (xy 151.037251 99.026695) (xy 151.037548 99.031848) (xy 151.037548 99.031851) - (xy 151.045715 99.173494) + (xy 151.047762 99.208988) (xy 151.05011 99.249715) - (xy 151.051248 99.254764) - (xy 151.052158 99.258802) - (xy 151.04762 99.329653) - (xy 151.005497 99.386804) - (xy 150.939163 99.412109) - (xy 150.92924 99.4125) - (xy 147.26902 99.4125) - (xy 147.200899 99.392498) - (xy 147.154406 99.338842) - (xy 147.144302 99.268568) - (xy 147.173796 99.203988) - (xy 147.213292 99.173494) + (xy 151.051247 99.254761) + (xy 151.051248 99.254767) + (xy 151.053284 99.263799) + (xy 151.048748 99.334651) + (xy 151.006626 99.391802) + (xy 150.940293 99.417108) + (xy 150.930367 99.4175) + (xy 147.258881 99.4175) + (xy 147.19076 99.397498) + (xy 147.144267 99.343842) + (xy 147.134163 99.273568) + (xy 147.163657 99.208988) + (xy 147.203153 99.178494) (xy 147.218133 99.171107) (xy 147.301676 99.129908) (xy 147.327969 99.116942) @@ -13472,15 +13579,15 @@ (xy 148.446746 97.408278) (xy 148.463076 97.159119) (xy 148.463346 97.155) - (xy 148.456982 97.057907) + (xy 148.458167 97.075985) (xy 148.444253 96.863686) (xy 148.444252 96.863679) (xy 148.443983 96.859574) - (xy 148.440126 96.840181) + (xy 148.443078 96.855021) (xy 148.38703 96.573253) (xy 148.387028 96.573247) (xy 148.386224 96.569203) - (xy 148.382735 96.558923) + (xy 148.384779 96.564944) (xy 148.359971 96.491863) (xy 151.03805 96.491863) (xy 151.050309 96.704477) @@ -13488,7 +13595,7 @@ (xy 151.098565 96.922446) (xy 151.101645 96.932275) (xy 151.18177 97.129603) - (xy 151.186413 97.138794) + (xy 151.186412 97.138792) (xy 151.26646 97.26942) (xy 151.276916 97.27888) (xy 151.285694 97.275096) @@ -13511,11 +13618,11 @@ (xy 148.292385 96.292761) (xy 148.292384 96.29276) (xy 148.291059 96.288855) - (xy 148.215075 96.134774) + (xy 148.206222 96.116823) (xy 148.161942 96.027031) (xy 148.161939 96.027026) (xy 148.160115 96.023327) - (xy 148.100096 95.933502) + (xy 148.116915 95.958674) (xy 147.997926 95.780593) (xy 147.997922 95.780588) (xy 147.995633 95.777162) @@ -13529,11 +13636,11 @@ (xy 147.577838 95.359367) (xy 147.574412 95.357078) (xy 147.574407 95.357074) - (xy 147.386783 95.231708) + (xy 147.335106 95.197179) (xy 147.331673 95.194885) (xy 147.327974 95.193061) (xy 147.327969 95.193058) - (xy 147.176078 95.118154) + (xy 147.191687 95.125852) (xy 147.066145 95.063941) (xy 146.988606 95.03762) (xy 146.78971 94.970104) @@ -13561,11 +13668,11 @@ (xy 145.61029 94.970104) (xy 145.411394 95.03762) (xy 145.333855 95.063941) - (xy 145.223922 95.118154) + (xy 145.208313 95.125852) (xy 145.072031 95.193058) (xy 145.072026 95.193061) (xy 145.068327 95.194885) - (xy 145.013217 95.231708) + (xy 145.064894 95.197179) (xy 144.825593 95.357074) (xy 144.825588 95.357078) (xy 144.822162 95.359367) @@ -13579,23 +13686,23 @@ (xy 144.404367 95.777162) (xy 144.402078 95.780588) (xy 144.402074 95.780593) - (xy 144.299904 95.933502) + (xy 144.283085 95.958674) (xy 144.239885 96.023327) (xy 144.238061 96.027026) (xy 144.238058 96.027031) - (xy 144.184925 96.134774) + (xy 144.193778 96.116823) (xy 144.108941 96.288855) (xy 144.107616 96.29276) (xy 144.107615 96.292761) - (xy 144.017266 96.558923) + (xy 144.015222 96.564944) (xy 144.013776 96.569203) (xy 144.012972 96.573247) (xy 144.01297 96.573253) - (xy 143.959875 96.840181) + (xy 143.956923 96.855021) (xy 143.956017 96.859574) (xy 143.955748 96.863679) (xy 143.955747 96.863686) - (xy 143.943018 97.057907) + (xy 143.941833 97.075985) (xy 143.936654 97.155) (xy 143.936924 97.159119) (xy 143.953255 97.408278) @@ -13630,21 +13737,21 @@ (xy 145.072031 99.116942) (xy 145.098324 99.129908) (xy 145.181868 99.171107) - (xy 145.186708 99.173494) - (xy 145.238957 99.221562) - (xy 145.256924 99.290248) - (xy 145.234905 99.357744) - (xy 145.17989 99.40262) - (xy 145.13098 99.4125) - (xy 144.345021 99.4125) - (xy 144.2769 99.392498) - (xy 144.255926 99.375595) - (xy 141.289405 96.409074) - (xy 141.255379 96.346762) - (xy 141.2525 96.319979) - (xy 141.2525 94.014206) - (xy 141.272502 93.946085) - (xy 141.284864 93.929896) + (xy 145.196847 99.178494) + (xy 145.249096 99.226562) + (xy 145.267063 99.295248) + (xy 145.245044 99.362744) + (xy 145.190029 99.40762) + (xy 145.141119 99.4175) + (xy 144.342949 99.4175) + (xy 144.274828 99.397498) + (xy 144.253854 99.380595) + (xy 141.284405 96.411145) + (xy 141.250379 96.348833) + (xy 141.2475 96.32205) + (xy 141.2475 94.019759) + (xy 141.267502 93.951638) + (xy 141.279864 93.935449) (xy 141.323621 93.886852) (xy 141.323622 93.886851) (xy 141.32804 93.881944) @@ -13672,14 +13779,14 @@ (xy 140.877319 92.478891) (xy 140.877318 92.478891) (xy 140.871288 92.476206) - (xy 140.771428 92.45498) + (xy 140.776227 92.456) (xy 140.690944 92.437872) (xy 140.690939 92.437872) (xy 140.684487 92.4365) (xy 140.493513 92.4365) (xy 140.487061 92.437872) (xy 140.487056 92.437872) - (xy 140.406572 92.45498) + (xy 140.401773 92.456) (xy 140.306712 92.476206) (xy 140.300682 92.478891) (xy 140.300681 92.478891) @@ -13707,220 +13814,227 @@ (xy 139.84996 93.881944) (xy 139.854378 93.886851) (xy 139.854379 93.886852) - (xy 139.893136 93.929896) - (xy 139.923854 93.993903) - (xy 139.9255 94.014206) - (xy 139.9255 96.619651) - (xy 139.925208 96.628221) - (xy 139.921543 96.68198) - (xy 139.931798 96.740742) - (xy 139.932756 96.747234) - (xy 139.936194 96.77564) - (xy 139.937401 96.785611) - (xy 139.93992 96.806429) - (xy 139.942603 96.813529) - (xy 139.944259 96.820272) - (xy 139.945841 96.826052) - (xy 139.947849 96.832704) - (xy 139.949154 96.840181) - (xy 139.952203 96.847126) - (xy 139.952205 96.847134) - (xy 139.973115 96.894768) - (xy 139.975607 96.900874) - (xy 139.983815 96.922596) - (xy 139.996685 96.956655) - (xy 140.000987 96.962914) - (xy 140.004204 96.969068) - (xy 140.007103 96.974277) - (xy 140.010651 96.980277) - (xy 140.013703 96.987229) - (xy 140.018326 96.993253) - (xy 140.018329 96.993259) - (xy 140.049994 97.034525) - (xy 140.053862 97.039848) - (xy 140.087646 97.089003) - (xy 140.093316 97.094055) - (xy 140.093317 97.094056) - (xy 140.131047 97.127672) - (xy 140.136323 97.132653) - (xy 143.529491 100.525822) - (xy 143.535344 100.532087) - (xy 143.570771 100.572698) - (xy 143.619557 100.606985) - (xy 143.624841 100.61091) - (xy 143.671764 100.647702) - (xy 143.678683 100.650826) - (xy 143.684629 100.654427) - (xy 143.689786 100.657368) - (xy 143.695944 100.66067) - (xy 143.70216 100.665039) - (xy 143.709236 100.667798) - (xy 143.709238 100.667799) - (xy 143.757696 100.686692) - (xy 143.763777 100.689248) - (xy 143.81121 100.710665) - (xy 143.818129 100.713789) - (xy 143.825595 100.715173) - (xy 143.832214 100.717247) - (xy 143.83799 100.718893) - (xy 143.844712 100.720619) - (xy 143.851782 100.723375) - (xy 143.85931 100.724366) - (xy 143.910893 100.731157) - (xy 143.917408 100.732189) - (xy 143.968564 100.74167) - (xy 143.968565 100.74167) - (xy 143.976032 100.743054) - (xy 143.983613 100.742617) - (xy 143.983614 100.742617) - (xy 144.034047 100.739709) - (xy 144.0413 100.7395) - (xy 151.356651 100.7395) - (xy 151.365221 100.739792) - (xy 151.411404 100.742941) - (xy 151.411408 100.742941) - (xy 151.41898 100.743457) - (xy 151.477742 100.733202) - (xy 151.484234 100.732244) - (xy 151.512723 100.728796) - (xy 151.535887 100.725993) - (xy 151.535889 100.725992) - (xy 151.543429 100.72508) - (xy 151.550529 100.722397) - (xy 151.557272 100.720741) - (xy 151.563052 100.719159) - (xy 151.569704 100.717151) - (xy 151.577181 100.715846) - (xy 151.584126 100.712797) - (xy 151.584134 100.712795) - (xy 151.631768 100.691885) - (xy 151.637874 100.689393) - (xy 151.686552 100.670999) - (xy 151.693655 100.668315) - (xy 151.699914 100.664013) - (xy 151.706068 100.660796) - (xy 151.711277 100.657897) - (xy 151.717277 100.654349) - (xy 151.724229 100.651297) - (xy 151.730253 100.646674) - (xy 151.730259 100.646671) - (xy 151.771525 100.615006) - (xy 151.776848 100.611138) - (xy 151.826003 100.577354) - (xy 151.832039 100.57058) - (xy 151.836182 100.56593) - (xy 170.89857 100.56593) - (xy 170.917035 100.800545) - (xy 170.918578 100.810292) - (xy 170.973517 101.039125) - (xy 170.976566 101.04851) - (xy 171.066625 101.265933) - (xy 171.071107 101.274728) - (xy 171.182072 101.455805) - (xy 171.19253 101.465267) - (xy 171.201306 101.461484) - (xy 172.088978 100.573812) - (xy 172.095356 100.562132) - (xy 172.825408 100.562132) - (xy 172.825539 100.563965) - (xy 172.82979 100.57058) - (xy 173.71765 101.45844) - (xy 173.73003 101.4652) - (xy 173.73768 101.459473) - (xy 173.850893 101.274728) - (xy 173.855375 101.265933) - (xy 173.945434 101.04851) - (xy 173.948483 101.039125) - (xy 174.003422 100.810292) - (xy 174.004965 100.800545) - (xy 174.02343 100.56593) - (xy 175.97857 100.56593) - (xy 175.997035 100.800545) - (xy 175.998578 100.810292) - (xy 176.053517 101.039125) - (xy 176.056566 101.04851) - (xy 176.146625 101.265933) - (xy 176.151107 101.274728) - (xy 176.262072 101.455805) - (xy 176.27253 101.465267) - (xy 176.281306 101.461484) - (xy 177.168978 100.573812) - (xy 177.175356 100.562132) - (xy 177.905408 100.562132) - (xy 177.905539 100.563965) - (xy 177.90979 100.57058) - (xy 178.79765 101.45844) - (xy 178.81003 101.4652) - (xy 178.81768 101.459473) - (xy 178.930893 101.274728) - (xy 178.935375 101.265933) - (xy 179.025434 101.04851) - (xy 179.028483 101.039125) - (xy 179.083422 100.810292) - (xy 179.084965 100.800545) - (xy 179.10343 100.56593) - (xy 179.10343 100.55607) - (xy 179.084965 100.321455) - (xy 179.083422 100.311708) - (xy 179.028483 100.082875) - (xy 179.025434 100.07349) - (xy 178.935375 99.856067) - (xy 178.930893 99.847272) - (xy 178.819928 99.666195) - (xy 178.80947 99.656733) - (xy 178.800694 99.660516) - (xy 177.913022 100.548188) - (xy 177.905408 100.562132) - (xy 177.175356 100.562132) - (xy 177.176592 100.559868) - (xy 177.176461 100.558035) - (xy 177.17221 100.55142) - (xy 176.28435 99.66356) - (xy 176.27197 99.6568) - (xy 176.26432 99.662527) - (xy 176.151107 99.847272) - (xy 176.146625 99.856067) - (xy 176.056566 100.07349) - (xy 176.053517 100.082875) - (xy 175.998578 100.311708) - (xy 175.997035 100.321455) - (xy 175.97857 100.55607) - (xy 175.97857 100.56593) - (xy 174.02343 100.56593) - (xy 174.02343 100.55607) - (xy 174.004965 100.321455) - (xy 174.003422 100.311708) - (xy 173.948483 100.082875) - (xy 173.945434 100.07349) - (xy 173.855375 99.856067) - (xy 173.850893 99.847272) - (xy 173.739928 99.666195) - (xy 173.72947 99.656733) - (xy 173.720694 99.660516) - (xy 172.833022 100.548188) - (xy 172.825408 100.562132) - (xy 172.095356 100.562132) - (xy 172.096592 100.559868) - (xy 172.096461 100.558035) - (xy 172.09221 100.55142) - (xy 171.20435 99.66356) - (xy 171.19197 99.6568) - (xy 171.18432 99.662527) - (xy 171.071107 99.847272) - (xy 171.066625 99.856067) - (xy 170.976566 100.07349) - (xy 170.973517 100.082875) - (xy 170.918578 100.311708) - (xy 170.917035 100.321455) - (xy 170.89857 100.55607) - (xy 170.89857 100.56593) - (xy 151.836182 100.56593) - (xy 151.864672 100.533953) - (xy 151.869653 100.528677) - (xy 151.979803 100.418527) - (xy 152.042115 100.384501) - (xy 152.094019 100.384152) - (xy 152.132018 100.391883) + (xy 139.898136 93.935449) + (xy 139.928854 93.999456) + (xy 139.9305 94.019759) + (xy 139.9305 96.564944) + (xy 139.929941 96.5768) + (xy 139.928212 96.584537) + (xy 139.928461 96.592459) + (xy 139.930438 96.655369) + (xy 139.9305 96.659327) + (xy 139.9305 96.688432) + (xy 139.931056 96.692832) + (xy 139.931988 96.704664) + (xy 139.933438 96.750831) + (xy 139.93565 96.758444) + (xy 139.93565 96.758445) + (xy 139.939419 96.771416) + (xy 139.94343 96.790782) + (xy 139.946118 96.812064) + (xy 139.949034 96.819429) + (xy 139.949035 96.819433) + (xy 139.963126 96.855021) + (xy 139.966965 96.866231) + (xy 139.979855 96.9106) + (xy 139.990775 96.929065) + (xy 139.999466 96.946805) + (xy 140.007365 96.966756) + (xy 140.018226 96.981705) + (xy 140.034516 97.004126) + (xy 140.041033 97.014048) + (xy 140.060507 97.046977) + (xy 140.06051 97.046981) + (xy 140.064547 97.053807) + (xy 140.079711 97.068971) + (xy 140.092551 97.084004) + (xy 140.105159 97.101357) + (xy 140.139303 97.129603) + (xy 140.140752 97.130802) + (xy 140.149532 97.138792) + (xy 143.494341 100.4836) + (xy 143.502331 100.492381) + (xy 143.502339 100.49239) + (xy 143.506584 100.49908) + (xy 143.528514 100.519674) + (xy 143.558274 100.54762) + (xy 143.561116 100.550375) + (xy 143.581667 100.570926) + (xy 143.584801 100.573357) + (xy 143.585163 100.573638) + (xy 143.594191 100.581348) + (xy 143.627867 100.612972) + (xy 143.634818 100.616793) + (xy 143.634819 100.616794) + (xy 143.646655 100.623301) + (xy 143.663184 100.634158) + (xy 143.673869 100.642447) + (xy 143.673871 100.642448) + (xy 143.680131 100.647304) + (xy 143.722544 100.665657) + (xy 143.733181 100.670868) + (xy 143.773663 100.693124) + (xy 143.781342 100.695096) + (xy 143.781343 100.695096) + (xy 143.794434 100.698457) + (xy 143.813136 100.704859) + (xy 143.832823 100.713379) + (xy 143.840652 100.714619) + (xy 143.878448 100.720605) + (xy 143.890074 100.723013) + (xy 143.927135 100.732529) + (xy 143.927136 100.732529) + (xy 143.934812 100.7345) + (xy 143.956258 100.7345) + (xy 143.975968 100.736051) + (xy 143.997151 100.739406) + (xy 144.043135 100.735059) + (xy 144.054994 100.7345) + (xy 151.301944 100.7345) + (xy 151.3138 100.735059) + (xy 151.313803 100.735059) + (xy 151.321537 100.736788) + (xy 151.392369 100.734562) + (xy 151.396327 100.7345) + (xy 151.425432 100.7345) + (xy 151.429832 100.733944) + (xy 151.441664 100.733012) + (xy 151.487831 100.731562) + (xy 151.508421 100.72558) + (xy 151.527782 100.72157) + (xy 151.535424 100.720605) + (xy 151.541204 100.719875) + (xy 151.541205 100.719875) + (xy 151.549064 100.718882) + (xy 151.556429 100.715966) + (xy 151.556433 100.715965) + (xy 151.592021 100.701874) + (xy 151.603231 100.698035) + (xy 151.6476 100.685145) + (xy 151.666065 100.674225) + (xy 151.683805 100.665534) + (xy 151.703756 100.657635) + (xy 151.741129 100.630482) + (xy 151.751048 100.623967) + (xy 151.783977 100.604493) + (xy 151.783981 100.60449) + (xy 151.790807 100.600453) + (xy 151.805971 100.585289) + (xy 151.821005 100.572448) + (xy 151.829976 100.56593) + (xy 170.94857 100.56593) + (xy 170.967035 100.800545) + (xy 170.968578 100.810292) + (xy 171.023517 101.039125) + (xy 171.026566 101.04851) + (xy 171.116625 101.265933) + (xy 171.121107 101.274728) + (xy 171.232072 101.455805) + (xy 171.24253 101.465267) + (xy 171.251306 101.461484) + (xy 172.138978 100.573812) + (xy 172.145356 100.562132) + (xy 172.875408 100.562132) + (xy 172.875539 100.563965) + (xy 172.87979 100.57058) + (xy 173.76765 101.45844) + (xy 173.78003 101.4652) + (xy 173.78768 101.459473) + (xy 173.900893 101.274728) + (xy 173.905375 101.265933) + (xy 173.995434 101.04851) + (xy 173.998483 101.039125) + (xy 174.053422 100.810292) + (xy 174.054965 100.800545) + (xy 174.07343 100.56593) + (xy 176.02857 100.56593) + (xy 176.047035 100.800545) + (xy 176.048578 100.810292) + (xy 176.103517 101.039125) + (xy 176.106566 101.04851) + (xy 176.196625 101.265933) + (xy 176.201107 101.274728) + (xy 176.312072 101.455805) + (xy 176.32253 101.465267) + (xy 176.331306 101.461484) + (xy 177.218978 100.573812) + (xy 177.225356 100.562132) + (xy 177.955408 100.562132) + (xy 177.955539 100.563965) + (xy 177.95979 100.57058) + (xy 178.84765 101.45844) + (xy 178.86003 101.4652) + (xy 178.86768 101.459473) + (xy 178.980893 101.274728) + (xy 178.985375 101.265933) + (xy 179.075434 101.04851) + (xy 179.078483 101.039125) + (xy 179.133422 100.810292) + (xy 179.134965 100.800545) + (xy 179.15343 100.56593) + (xy 179.15343 100.55607) + (xy 179.134965 100.321455) + (xy 179.133422 100.311708) + (xy 179.078483 100.082875) + (xy 179.075434 100.07349) + (xy 178.985375 99.856067) + (xy 178.980893 99.847272) + (xy 178.869928 99.666195) + (xy 178.85947 99.656733) + (xy 178.850694 99.660516) + (xy 177.963022 100.548188) + (xy 177.955408 100.562132) + (xy 177.225356 100.562132) + (xy 177.226592 100.559868) + (xy 177.226461 100.558035) + (xy 177.22221 100.55142) + (xy 176.33435 99.66356) + (xy 176.32197 99.6568) + (xy 176.31432 99.662527) + (xy 176.201107 99.847272) + (xy 176.196625 99.856067) + (xy 176.106566 100.07349) + (xy 176.103517 100.082875) + (xy 176.048578 100.311708) + (xy 176.047035 100.321455) + (xy 176.02857 100.55607) + (xy 176.02857 100.56593) + (xy 174.07343 100.56593) + (xy 174.07343 100.55607) + (xy 174.054965 100.321455) + (xy 174.053422 100.311708) + (xy 173.998483 100.082875) + (xy 173.995434 100.07349) + (xy 173.905375 99.856067) + (xy 173.900893 99.847272) + (xy 173.789928 99.666195) + (xy 173.77947 99.656733) + (xy 173.770694 99.660516) + (xy 172.883022 100.548188) + (xy 172.875408 100.562132) + (xy 172.145356 100.562132) + (xy 172.146592 100.559868) + (xy 172.146461 100.558035) + (xy 172.14221 100.55142) + (xy 171.25435 99.66356) + (xy 171.24197 99.6568) + (xy 171.23432 99.662527) + (xy 171.121107 99.847272) + (xy 171.116625 99.856067) + (xy 171.026566 100.07349) + (xy 171.023517 100.082875) + (xy 170.968578 100.311708) + (xy 170.967035 100.321455) + (xy 170.94857 100.55607) + (xy 170.94857 100.56593) + (xy 151.829976 100.56593) + (xy 151.831943 100.564501) + (xy 151.838357 100.559841) + (xy 151.867803 100.524247) + (xy 151.875792 100.515468) + (xy 151.973928 100.417332) + (xy 152.03624 100.383306) + (xy 152.08814 100.382956) (xy 152.238597 100.413567) (xy 152.243772 100.413757) (xy 152.243774 100.413757) @@ -13932,7 +14046,7 @@ (xy 152.678288 100.394025) (xy 152.678289 100.394025) (xy 152.683416 100.393368) - (xy 152.712971 100.384501) + (xy 152.688366 100.391883) (xy 152.892429 100.330661) (xy 152.892434 100.330659) (xy 152.897384 100.329174) @@ -13946,7 +14060,7 @@ (xy 153.665136 99.566453) (xy 153.665137 99.566451) (xy 153.66743 99.561811) - (xy 153.729431 99.357744) + (xy 153.722488 99.380595) (xy 153.730865 99.353023) (xy 153.730865 99.353021) (xy 153.73237 99.348069) @@ -13956,10 +14070,10 @@ (xy 153.763074 99.063361) (xy 153.763156 99.06) (xy 153.744852 98.837361) - (xy 153.725338 98.759672) - (xy 153.728142 98.688732) - (xy 153.758447 98.639883) - (xy 154.849236 97.549095) + (xy 153.723919 98.754022) + (xy 153.726723 98.683081) + (xy 153.757028 98.634232) + (xy 154.842165 97.549095) (xy 155.797001 97.549095) (xy 155.797338 97.555614) (xy 155.807257 97.651206) @@ -14082,24 +14196,31 @@ (xy 155.798672 97.261865) (xy 155.797001 97.269548) (xy 155.797001 97.549095) - (xy 154.849236 97.549095) - (xy 155.639088 96.759243) - (xy 155.7014 96.725217) - (xy 155.772216 96.730282) - (xy 155.797173 96.745091) + (xy 154.842165 97.549095) + (xy 155.635299 96.755961) + (xy 155.697611 96.721935) + (xy 155.768426 96.727) + (xy 155.799925 96.745689) (xy 155.810548 96.748) (xy 159.144884 96.748) (xy 159.160123 96.743525) (xy 159.161328 96.742135) (xy 159.162999 96.734452) - (xy 159.162999 96.5475) - (xy 159.183001 96.479379) - (xy 159.236657 96.432886) - (xy 159.288999 96.4215) - (xy 161.005 96.4215) - (xy 161.073121 96.441502) - (xy 161.119614 96.495158) - (xy 161.131 96.5475) + (xy 159.162999 96.454905) + (xy 159.162662 96.448386) + (xy 159.152032 96.345937) + (xy 159.154363 96.345695) + (xy 159.158748 96.285789) + (xy 159.20139 96.229024) + (xy 159.267952 96.204325) + (xy 159.27673 96.204019) + (xy 161.017291 96.204019) + (xy 161.085412 96.224021) + (xy 161.131905 96.277677) + (xy 161.142009 96.347951) + (xy 161.141106 96.352998) + (xy 161.131328 96.448438) + (xy 161.131 96.454855) (xy 161.131 96.729885) (xy 161.135475 96.745124) (xy 161.136865 96.746329) @@ -14111,19 +14232,37 @@ (xy 164.496999 96.454905) (xy 164.496662 96.448386) (xy 164.486743 96.352794) - (xy 164.48385 96.339397) - (xy 164.465995 96.285876) - (xy 164.463411 96.214927) - (xy 164.496424 96.156906) - (xy 166.183633 94.469698) - (xy 166.245945 94.435672) - (xy 166.316761 94.440737) - (xy 166.373596 94.483284) - (xy 166.389471 94.511389) - (xy 166.41997 94.5865) + (xy 164.483849 96.339392) + (xy 164.475868 96.315469) + (xy 164.473283 96.24452) + (xy 164.509466 96.183436) + (xy 164.54535 96.159956) + (xy 164.552468 96.156876) + (xy 164.560081 96.154664) + (xy 164.578546 96.143744) + (xy 164.596286 96.135053) + (xy 164.616237 96.127154) + (xy 164.65361 96.100001) + (xy 164.663529 96.093486) + (xy 164.696458 96.074012) + (xy 164.696462 96.074009) + (xy 164.703288 96.069972) + (xy 164.718452 96.054808) + (xy 164.733486 96.041967) + (xy 164.750838 96.02936) + (xy 164.780284 95.993766) + (xy 164.788273 95.984987) + (xy 165.48423 95.28903) + (xy 166.218403 94.554856) + (xy 166.280715 94.520831) + (xy 166.35153 94.525895) + (xy 166.408366 94.568442) + (xy 166.419963 94.587139) + (xy 166.421322 94.589829) (xy 166.423266 94.594616) - (xy 166.425965 94.59902) - (xy 166.500177 94.720123) + (xy 166.425963 94.599018) + (xy 166.425964 94.599019) + (xy 166.525936 94.762158) (xy 166.539987 94.785088) (xy 166.68625 94.953938) (xy 166.858126 95.096632) @@ -14148,7 +14287,7 @@ (xy 166.277251 96.486695) (xy 166.277548 96.491848) (xy 166.277548 96.491851) - (xy 166.283202 96.589908) + (xy 166.289136 96.692819) (xy 166.29011 96.709715) (xy 166.291247 96.714761) (xy 166.291248 96.714767) @@ -14182,7 +14321,7 @@ (xy 166.277251 99.026695) (xy 166.277548 99.031848) (xy 166.277548 99.031851) - (xy 166.285715 99.173494) + (xy 166.287762 99.208988) (xy 166.29011 99.249715) (xy 166.291247 99.254761) (xy 166.291248 99.254767) @@ -14198,7 +14337,7 @@ (xy 167.259692 100.36903) (xy 167.26476 100.370061) (xy 167.264763 100.370062) - (xy 167.372017 100.391883) + (xy 167.32986 100.383306) (xy 167.478597 100.413567) (xy 167.483772 100.413757) (xy 167.483774 100.413757) @@ -14210,7 +14349,7 @@ (xy 167.918288 100.394025) (xy 167.918289 100.394025) (xy 167.923416 100.393368) - (xy 167.952971 100.384501) + (xy 167.928366 100.391883) (xy 168.132429 100.330661) (xy 168.132434 100.330659) (xy 168.137384 100.329174) @@ -14224,63 +14363,63 @@ (xy 168.905136 99.566453) (xy 168.905137 99.566451) (xy 168.90743 99.561811) - (xy 168.969431 99.357744) + (xy 168.962488 99.380595) (xy 168.970865 99.353023) (xy 168.970865 99.353021) (xy 168.97237 99.348069) (xy 168.979682 99.29253) - (xy 171.556733 99.29253) - (xy 171.560516 99.301306) - (xy 172.448188 100.188978) - (xy 172.462132 100.196592) - (xy 172.463965 100.196461) - (xy 172.47058 100.19221) - (xy 173.35844 99.30435) - (xy 173.364894 99.29253) - (xy 176.636733 99.29253) - (xy 176.640516 99.301306) - (xy 177.528188 100.188978) - (xy 177.542132 100.196592) - (xy 177.543965 100.196461) - (xy 177.55058 100.19221) - (xy 178.43844 99.30435) - (xy 178.4452 99.29197) - (xy 178.439473 99.28432) - (xy 178.254728 99.171107) - (xy 178.245933 99.166625) - (xy 178.02851 99.076566) - (xy 178.019125 99.073517) - (xy 177.790292 99.018578) - (xy 177.780545 99.017035) - (xy 177.54593 98.99857) - (xy 177.53607 98.99857) - (xy 177.301455 99.017035) - (xy 177.291708 99.018578) - (xy 177.062875 99.073517) - (xy 177.05349 99.076566) - (xy 176.836067 99.166625) - (xy 176.827272 99.171107) - (xy 176.646195 99.282072) - (xy 176.636733 99.29253) - (xy 173.364894 99.29253) - (xy 173.3652 99.29197) - (xy 173.359473 99.28432) - (xy 173.174728 99.171107) - (xy 173.165933 99.166625) - (xy 172.94851 99.076566) - (xy 172.939125 99.073517) - (xy 172.710292 99.018578) - (xy 172.700545 99.017035) - (xy 172.46593 98.99857) - (xy 172.45607 98.99857) - (xy 172.221455 99.017035) - (xy 172.211708 99.018578) - (xy 171.982875 99.073517) - (xy 171.97349 99.076566) - (xy 171.756067 99.166625) - (xy 171.747272 99.171107) - (xy 171.566195 99.282072) - (xy 171.556733 99.29253) + (xy 171.606733 99.29253) + (xy 171.610516 99.301306) + (xy 172.498188 100.188978) + (xy 172.512132 100.196592) + (xy 172.513965 100.196461) + (xy 172.52058 100.19221) + (xy 173.40844 99.30435) + (xy 173.414894 99.29253) + (xy 176.686733 99.29253) + (xy 176.690516 99.301306) + (xy 177.578188 100.188978) + (xy 177.592132 100.196592) + (xy 177.593965 100.196461) + (xy 177.60058 100.19221) + (xy 178.48844 99.30435) + (xy 178.4952 99.29197) + (xy 178.489473 99.28432) + (xy 178.304728 99.171107) + (xy 178.295933 99.166625) + (xy 178.07851 99.076566) + (xy 178.069125 99.073517) + (xy 177.840292 99.018578) + (xy 177.830545 99.017035) + (xy 177.59593 98.99857) + (xy 177.58607 98.99857) + (xy 177.351455 99.017035) + (xy 177.341708 99.018578) + (xy 177.112875 99.073517) + (xy 177.10349 99.076566) + (xy 176.886067 99.166625) + (xy 176.877272 99.171107) + (xy 176.696195 99.282072) + (xy 176.686733 99.29253) + (xy 173.414894 99.29253) + (xy 173.4152 99.29197) + (xy 173.409473 99.28432) + (xy 173.224728 99.171107) + (xy 173.215933 99.166625) + (xy 172.99851 99.076566) + (xy 172.989125 99.073517) + (xy 172.760292 99.018578) + (xy 172.750545 99.017035) + (xy 172.51593 98.99857) + (xy 172.50607 98.99857) + (xy 172.271455 99.017035) + (xy 172.261708 99.018578) + (xy 172.032875 99.073517) + (xy 172.02349 99.076566) + (xy 171.806067 99.166625) + (xy 171.797272 99.171107) + (xy 171.616195 99.282072) + (xy 171.606733 99.29253) (xy 168.979682 99.29253) (xy 169.001529 99.12659) (xy 169.001765 99.116942) @@ -14317,63 +14456,63 @@ (xy 168.905136 97.026453) (xy 168.905137 97.026451) (xy 168.90743 97.021811) - (xy 168.957949 96.855535) + (xy 168.941219 96.9106) (xy 168.970865 96.813023) (xy 168.970865 96.813021) (xy 168.97237 96.808069) (xy 168.980011 96.75003) - (xy 171.5568 96.75003) - (xy 171.562527 96.75768) - (xy 171.747272 96.870893) - (xy 171.756067 96.875375) - (xy 171.97349 96.965434) - (xy 171.982875 96.968483) - (xy 172.211708 97.023422) - (xy 172.221455 97.024965) - (xy 172.45607 97.04343) - (xy 172.46593 97.04343) - (xy 172.700545 97.024965) - (xy 172.710292 97.023422) - (xy 172.939125 96.968483) - (xy 172.94851 96.965434) - (xy 173.165933 96.875375) - (xy 173.174728 96.870893) - (xy 173.355805 96.759928) - (xy 173.36476 96.75003) - (xy 176.6368 96.75003) - (xy 176.642527 96.75768) - (xy 176.827272 96.870893) - (xy 176.836067 96.875375) - (xy 177.05349 96.965434) - (xy 177.062875 96.968483) - (xy 177.291708 97.023422) - (xy 177.301455 97.024965) - (xy 177.53607 97.04343) - (xy 177.54593 97.04343) - (xy 177.780545 97.024965) - (xy 177.790292 97.023422) - (xy 178.019125 96.968483) - (xy 178.02851 96.965434) - (xy 178.245933 96.875375) - (xy 178.254728 96.870893) - (xy 178.435805 96.759928) - (xy 178.445267 96.74947) - (xy 178.441484 96.740694) - (xy 177.553812 95.853022) - (xy 177.539868 95.845408) - (xy 177.538035 95.845539) - (xy 177.53142 95.84979) - (xy 176.64356 96.73765) - (xy 176.6368 96.75003) - (xy 173.36476 96.75003) - (xy 173.365267 96.74947) - (xy 173.361484 96.740694) - (xy 172.473812 95.853022) - (xy 172.459868 95.845408) - (xy 172.458035 95.845539) - (xy 172.45142 95.84979) - (xy 171.56356 96.73765) - (xy 171.5568 96.75003) + (xy 171.6068 96.75003) + (xy 171.612527 96.75768) + (xy 171.797272 96.870893) + (xy 171.806067 96.875375) + (xy 172.02349 96.965434) + (xy 172.032875 96.968483) + (xy 172.261708 97.023422) + (xy 172.271455 97.024965) + (xy 172.50607 97.04343) + (xy 172.51593 97.04343) + (xy 172.750545 97.024965) + (xy 172.760292 97.023422) + (xy 172.989125 96.968483) + (xy 172.99851 96.965434) + (xy 173.215933 96.875375) + (xy 173.224728 96.870893) + (xy 173.405805 96.759928) + (xy 173.41476 96.75003) + (xy 176.6868 96.75003) + (xy 176.692527 96.75768) + (xy 176.877272 96.870893) + (xy 176.886067 96.875375) + (xy 177.10349 96.965434) + (xy 177.112875 96.968483) + (xy 177.341708 97.023422) + (xy 177.351455 97.024965) + (xy 177.58607 97.04343) + (xy 177.59593 97.04343) + (xy 177.830545 97.024965) + (xy 177.840292 97.023422) + (xy 178.069125 96.968483) + (xy 178.07851 96.965434) + (xy 178.295933 96.875375) + (xy 178.304728 96.870893) + (xy 178.485805 96.759928) + (xy 178.495267 96.74947) + (xy 178.491484 96.740694) + (xy 177.603812 95.853022) + (xy 177.589868 95.845408) + (xy 177.588035 95.845539) + (xy 177.58142 95.84979) + (xy 176.69356 96.73765) + (xy 176.6868 96.75003) + (xy 173.41476 96.75003) + (xy 173.415267 96.74947) + (xy 173.411484 96.740694) + (xy 172.523812 95.853022) + (xy 172.509868 95.845408) + (xy 172.508035 95.845539) + (xy 172.50142 95.84979) + (xy 171.61356 96.73765) + (xy 171.6068 96.75003) (xy 168.980011 96.75003) (xy 169.001529 96.58659) (xy 169.001954 96.569203) @@ -14395,111 +14534,111 @@ (xy 169.548158 95.504101) (xy 169.553586 95.498321) (xy 169.560398 95.48593) - (xy 170.89857 95.48593) - (xy 170.917035 95.720545) - (xy 170.918578 95.730292) - (xy 170.973517 95.959125) - (xy 170.976566 95.96851) - (xy 171.066625 96.185933) - (xy 171.071107 96.194728) - (xy 171.182072 96.375805) - (xy 171.19253 96.385267) - (xy 171.201306 96.381484) - (xy 172.088978 95.493812) - (xy 172.095356 95.482132) - (xy 172.825408 95.482132) - (xy 172.825539 95.483965) - (xy 172.82979 95.49058) - (xy 173.71765 96.37844) - (xy 173.73003 96.3852) - (xy 173.73768 96.379473) - (xy 173.850893 96.194728) - (xy 173.855375 96.185933) - (xy 173.945434 95.96851) - (xy 173.948483 95.959125) - (xy 174.003422 95.730292) - (xy 174.004965 95.720545) - (xy 174.02343 95.48593) - (xy 175.97857 95.48593) - (xy 175.997035 95.720545) - (xy 175.998578 95.730292) - (xy 176.053517 95.959125) - (xy 176.056566 95.96851) - (xy 176.146625 96.185933) - (xy 176.151107 96.194728) - (xy 176.262072 96.375805) - (xy 176.27253 96.385267) - (xy 176.281306 96.381484) - (xy 177.168978 95.493812) - (xy 177.175356 95.482132) - (xy 177.905408 95.482132) - (xy 177.905539 95.483965) - (xy 177.90979 95.49058) - (xy 178.79765 96.37844) - (xy 178.81003 96.3852) - (xy 178.81768 96.379473) - (xy 178.930893 96.194728) - (xy 178.935375 96.185933) - (xy 179.025434 95.96851) - (xy 179.028483 95.959125) - (xy 179.083422 95.730292) - (xy 179.084965 95.720545) - (xy 179.10343 95.48593) - (xy 179.10343 95.47607) - (xy 179.084965 95.241455) - (xy 179.083422 95.231708) - (xy 179.028483 95.002875) - (xy 179.025434 94.99349) - (xy 178.935375 94.776067) - (xy 178.930893 94.767272) - (xy 178.819928 94.586195) - (xy 178.80947 94.576733) - (xy 178.800694 94.580516) - (xy 177.913022 95.468188) - (xy 177.905408 95.482132) - (xy 177.175356 95.482132) - (xy 177.176592 95.479868) - (xy 177.176461 95.478035) - (xy 177.17221 95.47142) - (xy 176.28435 94.58356) - (xy 176.27197 94.5768) - (xy 176.26432 94.582527) - (xy 176.151107 94.767272) - (xy 176.146625 94.776067) - (xy 176.056566 94.99349) - (xy 176.053517 95.002875) - (xy 175.998578 95.231708) - (xy 175.997035 95.241455) - (xy 175.97857 95.47607) - (xy 175.97857 95.48593) - (xy 174.02343 95.48593) - (xy 174.02343 95.47607) - (xy 174.004965 95.241455) - (xy 174.003422 95.231708) - (xy 173.948483 95.002875) - (xy 173.945434 94.99349) - (xy 173.855375 94.776067) - (xy 173.850893 94.767272) - (xy 173.739928 94.586195) - (xy 173.72947 94.576733) - (xy 173.720694 94.580516) - (xy 172.833022 95.468188) - (xy 172.825408 95.482132) - (xy 172.095356 95.482132) - (xy 172.096592 95.479868) - (xy 172.096461 95.478035) - (xy 172.09221 95.47142) - (xy 171.20435 94.58356) - (xy 171.19197 94.5768) - (xy 171.18432 94.582527) - (xy 171.071107 94.767272) - (xy 171.066625 94.776067) - (xy 170.976566 94.99349) - (xy 170.973517 95.002875) - (xy 170.918578 95.231708) - (xy 170.917035 95.241455) - (xy 170.89857 95.47607) - (xy 170.89857 95.48593) + (xy 170.94857 95.48593) + (xy 170.967035 95.720545) + (xy 170.968578 95.730292) + (xy 171.023517 95.959125) + (xy 171.026566 95.96851) + (xy 171.116625 96.185933) + (xy 171.121107 96.194728) + (xy 171.232072 96.375805) + (xy 171.24253 96.385267) + (xy 171.251306 96.381484) + (xy 172.138978 95.493812) + (xy 172.145356 95.482132) + (xy 172.875408 95.482132) + (xy 172.875539 95.483965) + (xy 172.87979 95.49058) + (xy 173.76765 96.37844) + (xy 173.78003 96.3852) + (xy 173.78768 96.379473) + (xy 173.900893 96.194728) + (xy 173.905375 96.185933) + (xy 173.995434 95.96851) + (xy 173.998483 95.959125) + (xy 174.053422 95.730292) + (xy 174.054965 95.720545) + (xy 174.07343 95.48593) + (xy 176.02857 95.48593) + (xy 176.047035 95.720545) + (xy 176.048578 95.730292) + (xy 176.103517 95.959125) + (xy 176.106566 95.96851) + (xy 176.196625 96.185933) + (xy 176.201107 96.194728) + (xy 176.312072 96.375805) + (xy 176.32253 96.385267) + (xy 176.331306 96.381484) + (xy 177.218978 95.493812) + (xy 177.225356 95.482132) + (xy 177.955408 95.482132) + (xy 177.955539 95.483965) + (xy 177.95979 95.49058) + (xy 178.84765 96.37844) + (xy 178.86003 96.3852) + (xy 178.86768 96.379473) + (xy 178.980893 96.194728) + (xy 178.985375 96.185933) + (xy 179.075434 95.96851) + (xy 179.078483 95.959125) + (xy 179.133422 95.730292) + (xy 179.134965 95.720545) + (xy 179.15343 95.48593) + (xy 179.15343 95.47607) + (xy 179.134965 95.241455) + (xy 179.133422 95.231708) + (xy 179.078483 95.002875) + (xy 179.075434 94.99349) + (xy 178.985375 94.776067) + (xy 178.980893 94.767272) + (xy 178.869928 94.586195) + (xy 178.85947 94.576733) + (xy 178.850694 94.580516) + (xy 177.963022 95.468188) + (xy 177.955408 95.482132) + (xy 177.225356 95.482132) + (xy 177.226592 95.479868) + (xy 177.226461 95.478035) + (xy 177.22221 95.47142) + (xy 176.33435 94.58356) + (xy 176.32197 94.5768) + (xy 176.31432 94.582527) + (xy 176.201107 94.767272) + (xy 176.196625 94.776067) + (xy 176.106566 94.99349) + (xy 176.103517 95.002875) + (xy 176.048578 95.231708) + (xy 176.047035 95.241455) + (xy 176.02857 95.47607) + (xy 176.02857 95.48593) + (xy 174.07343 95.48593) + (xy 174.07343 95.47607) + (xy 174.054965 95.241455) + (xy 174.053422 95.231708) + (xy 173.998483 95.002875) + (xy 173.995434 94.99349) + (xy 173.905375 94.776067) + (xy 173.900893 94.767272) + (xy 173.789928 94.586195) + (xy 173.77947 94.576733) + (xy 173.770694 94.580516) + (xy 172.883022 95.468188) + (xy 172.875408 95.482132) + (xy 172.145356 95.482132) + (xy 172.146592 95.479868) + (xy 172.146461 95.478035) + (xy 172.14221 95.47142) + (xy 171.25435 94.58356) + (xy 171.24197 94.5768) + (xy 171.23432 94.582527) + (xy 171.121107 94.767272) + (xy 171.116625 94.776067) + (xy 171.026566 94.99349) + (xy 171.023517 95.002875) + (xy 170.968578 95.231708) + (xy 170.967035 95.241455) + (xy 170.94857 95.47607) + (xy 170.94857 95.48593) (xy 169.560398 95.48593) (xy 169.563346 95.480568) (xy 169.574199 95.464045) @@ -14526,58 +14665,58 @@ (xy 169.671059 95.099046) (xy 169.6705 95.087189) (xy 169.6705 94.21253) - (xy 171.556733 94.21253) - (xy 171.560516 94.221306) - (xy 172.448188 95.108978) - (xy 172.462132 95.116592) - (xy 172.463965 95.116461) - (xy 172.47058 95.11221) - (xy 173.35844 94.22435) - (xy 173.364894 94.21253) - (xy 176.636733 94.21253) - (xy 176.640516 94.221306) - (xy 177.528188 95.108978) - (xy 177.542132 95.116592) - (xy 177.543965 95.116461) - (xy 177.55058 95.11221) - (xy 178.43844 94.22435) - (xy 178.4452 94.21197) - (xy 178.439473 94.20432) - (xy 178.254728 94.091107) - (xy 178.245933 94.086625) - (xy 178.02851 93.996566) - (xy 178.019125 93.993517) - (xy 177.790292 93.938578) - (xy 177.780545 93.937035) - (xy 177.54593 93.91857) - (xy 177.53607 93.91857) - (xy 177.301455 93.937035) - (xy 177.291708 93.938578) - (xy 177.062875 93.993517) - (xy 177.05349 93.996566) - (xy 176.836067 94.086625) - (xy 176.827272 94.091107) - (xy 176.646195 94.202072) - (xy 176.636733 94.21253) - (xy 173.364894 94.21253) - (xy 173.3652 94.21197) - (xy 173.359473 94.20432) - (xy 173.174728 94.091107) - (xy 173.165933 94.086625) - (xy 172.94851 93.996566) - (xy 172.939125 93.993517) - (xy 172.710292 93.938578) - (xy 172.700545 93.937035) - (xy 172.46593 93.91857) - (xy 172.45607 93.91857) - (xy 172.221455 93.937035) - (xy 172.211708 93.938578) - (xy 171.982875 93.993517) - (xy 171.97349 93.996566) - (xy 171.756067 94.086625) - (xy 171.747272 94.091107) - (xy 171.566195 94.202072) - (xy 171.556733 94.21253) + (xy 171.606733 94.21253) + (xy 171.610516 94.221306) + (xy 172.498188 95.108978) + (xy 172.512132 95.116592) + (xy 172.513965 95.116461) + (xy 172.52058 95.11221) + (xy 173.40844 94.22435) + (xy 173.414894 94.21253) + (xy 176.686733 94.21253) + (xy 176.690516 94.221306) + (xy 177.578188 95.108978) + (xy 177.592132 95.116592) + (xy 177.593965 95.116461) + (xy 177.60058 95.11221) + (xy 178.48844 94.22435) + (xy 178.4952 94.21197) + (xy 178.489473 94.20432) + (xy 178.304728 94.091107) + (xy 178.295933 94.086625) + (xy 178.07851 93.996566) + (xy 178.069125 93.993517) + (xy 177.840292 93.938578) + (xy 177.830545 93.937035) + (xy 177.59593 93.91857) + (xy 177.58607 93.91857) + (xy 177.351455 93.937035) + (xy 177.341708 93.938578) + (xy 177.112875 93.993517) + (xy 177.10349 93.996566) + (xy 176.886067 94.086625) + (xy 176.877272 94.091107) + (xy 176.696195 94.202072) + (xy 176.686733 94.21253) + (xy 173.414894 94.21253) + (xy 173.4152 94.21197) + (xy 173.409473 94.20432) + (xy 173.224728 94.091107) + (xy 173.215933 94.086625) + (xy 172.99851 93.996566) + (xy 172.989125 93.993517) + (xy 172.760292 93.938578) + (xy 172.750545 93.937035) + (xy 172.51593 93.91857) + (xy 172.50607 93.91857) + (xy 172.271455 93.937035) + (xy 172.261708 93.938578) + (xy 172.032875 93.993517) + (xy 172.02349 93.996566) + (xy 171.806067 94.086625) + (xy 171.797272 94.091107) + (xy 171.616195 94.202072) + (xy 171.606733 94.21253) (xy 169.6705 94.21253) (xy 169.6705 93.405594) (xy 169.690502 93.337473) @@ -14743,67 +14882,169 @@ (xy 171.551944 83.039872) (xy 171.551939 83.039872) (xy 171.545487 83.0385) - (xy 171.532021 83.0385) - (xy 171.4639 83.018498) - (xy 171.442925 83.001595) - (xy 171.261404 82.820073) - (xy 171.227379 82.757761) - (xy 171.2245 82.730978) - (xy 171.2245 73.948206) - (xy 171.244502 73.880085) - (xy 171.256864 73.863896) - (xy 171.295621 73.820852) - (xy 171.295622 73.820851) - (xy 171.30004 73.815944) - (xy 171.358314 73.71501) - (xy 171.392223 73.656279) - (xy 171.392224 73.656278) - (xy 171.395527 73.650556) - (xy 171.454542 73.468928) - (xy 171.474504 73.279) - (xy 171.465685 73.195088) - (xy 171.455232 73.095635) - (xy 171.455232 73.095633) - (xy 171.454542 73.089072) - (xy 171.395527 72.907444) - (xy 171.30004 72.742056) - (xy 171.256864 72.694104) - (xy 171.226146 72.630097) - (xy 171.2245 72.609794) - (xy 171.2245 68.653021) - (xy 171.244502 68.5849) - (xy 171.261405 68.563925) - (xy 171.628194 68.197137) - (xy 172.026829 67.798502) - (xy 172.033095 67.792649) - (xy 172.067971 67.762225) - (xy 172.073698 67.757229) - (xy 172.107985 67.708443) - (xy 172.11191 67.703159) - (xy 172.144017 67.662211) - (xy 172.148702 67.656236) - (xy 172.151826 67.649317) - (xy 172.155427 67.643371) - (xy 172.158368 67.638214) - (xy 172.16167 67.632056) - (xy 172.166039 67.62584) - (xy 172.187692 67.570304) - (xy 172.190248 67.564223) - (xy 172.211665 67.51679) - (xy 172.211665 67.516789) - (xy 172.214789 67.509871) - (xy 172.216173 67.502405) - (xy 172.218247 67.495786) - (xy 172.219885 67.490037) - (xy 172.221615 67.483296) - (xy 172.224375 67.476218) - (xy 172.232156 67.417112) - (xy 172.233188 67.410595) - (xy 172.24267 67.359434) - (xy 172.244054 67.351967) - (xy 172.240709 67.293953) - (xy 172.2405 67.2867) - (xy 172.2405 63.142064) + (xy 171.52495 83.0385) + (xy 171.456829 83.018498) + (xy 171.435855 83.001595) + (xy 171.256405 82.822145) + (xy 171.222379 82.759833) + (xy 171.2195 82.73305) + (xy 171.2195 75.173002) + (xy 171.239502 75.104881) + (xy 171.293158 75.058388) + (xy 171.363432 75.048284) + (xy 171.428012 75.077778) + (xy 171.442419 75.092518) + (xy 171.446584 75.09908) + (xy 171.47538 75.126121) + (xy 171.498273 75.147619) + (xy 171.501115 75.150374) + (xy 171.521667 75.170926) + (xy 171.524801 75.173357) + (xy 171.525163 75.173638) + (xy 171.534191 75.181348) + (xy 171.567867 75.212972) + (xy 171.574818 75.216793) + (xy 171.574819 75.216794) + (xy 171.586655 75.223301) + (xy 171.603184 75.234158) + (xy 171.613869 75.242447) + (xy 171.613871 75.242448) + (xy 171.620131 75.247304) + (xy 171.662544 75.265657) + (xy 171.673181 75.270868) + (xy 171.713663 75.293124) + (xy 171.721342 75.295096) + (xy 171.721343 75.295096) + (xy 171.734434 75.298457) + (xy 171.753136 75.304859) + (xy 171.772823 75.313379) + (xy 171.780652 75.314619) + (xy 171.818448 75.320605) + (xy 171.830074 75.323013) + (xy 171.867135 75.332529) + (xy 171.867136 75.332529) + (xy 171.874812 75.3345) + (xy 171.896258 75.3345) + (xy 171.915968 75.336051) + (xy 171.937151 75.339406) + (xy 171.983135 75.335059) + (xy 171.994994 75.3345) + (xy 179.913776 75.3345) + (xy 179.981897 75.354502) + (xy 179.987834 75.358562) + (xy 179.995948 75.364457) + (xy 180.104609 75.443404) + (xy 180.137248 75.467118) + (xy 180.143276 75.469802) + (xy 180.143278 75.469803) + (xy 180.305681 75.542109) + (xy 180.311712 75.544794) + (xy 180.395134 75.562526) + (xy 180.492056 75.583128) + (xy 180.492061 75.583128) + (xy 180.498513 75.5845) + (xy 180.689487 75.5845) + (xy 180.695939 75.583128) + (xy 180.695944 75.583128) + (xy 180.792866 75.562526) + (xy 180.876288 75.544794) + (xy 180.882319 75.542109) + (xy 181.044722 75.469803) + (xy 181.044724 75.469802) + (xy 181.050752 75.467118) + (xy 181.083392 75.443404) + (xy 181.106166 75.426857) + (xy 181.205253 75.354866) + (xy 181.214307 75.344811) + (xy 181.328621 75.217852) + (xy 181.328622 75.217851) + (xy 181.33304 75.212944) + (xy 181.428527 75.047556) + (xy 181.487542 74.865928) + (xy 181.488637 74.855516) + (xy 181.506814 74.682565) + (xy 181.507504 74.676) + (xy 181.487542 74.486072) + (xy 181.428527 74.304444) + (xy 181.422209 74.2935) + (xy 181.336341 74.144774) + (xy 181.33304 74.139056) + (xy 181.300509 74.102926) + (xy 181.209675 74.002045) + (xy 181.209674 74.002044) + (xy 181.205253 73.997134) + (xy 181.050752 73.884882) + (xy 181.044724 73.882198) + (xy 181.044722 73.882197) + (xy 180.882319 73.809891) + (xy 180.882318 73.809891) + (xy 180.876288 73.807206) + (xy 180.782887 73.787353) + (xy 180.695944 73.768872) + (xy 180.695939 73.768872) + (xy 180.689487 73.7675) + (xy 180.498513 73.7675) + (xy 180.492061 73.768872) + (xy 180.492056 73.768872) + (xy 180.405113 73.787353) + (xy 180.311712 73.807206) + (xy 180.305682 73.809891) + (xy 180.305681 73.809891) + (xy 180.143278 73.882197) + (xy 180.143276 73.882198) + (xy 180.137248 73.884882) + (xy 180.131907 73.888762) + (xy 180.131906 73.888763) + (xy 180.075358 73.929848) + (xy 179.988092 73.993251) + (xy 179.987837 73.993436) + (xy 179.920969 74.017294) + (xy 179.913776 74.0175) + (xy 172.282949 74.0175) + (xy 172.214828 73.997498) + (xy 172.193858 73.980599) + (xy 171.256403 73.043143) + (xy 171.222379 72.980833) + (xy 171.2195 72.95405) + (xy 171.2195 68.65095) + (xy 171.239502 68.582829) + (xy 171.256405 68.561855) + (xy 171.984605 67.833655) + (xy 171.993385 67.825665) + (xy 171.993387 67.825663) + (xy 172.00008 67.821416) + (xy 172.048605 67.769742) + (xy 172.051359 67.766901) + (xy 172.071927 67.746333) + (xy 172.074647 67.742826) + (xy 172.082353 67.733804) + (xy 172.093033 67.722431) + (xy 172.113972 67.700133) + (xy 172.117794 67.693181) + (xy 172.124303 67.681342) + (xy 172.135157 67.664818) + (xy 172.143445 67.654132) + (xy 172.148304 67.647868) + (xy 172.153919 67.634893) + (xy 172.166654 67.605465) + (xy 172.171876 67.594805) + (xy 172.190305 67.561284) + (xy 172.190306 67.561282) + (xy 172.194124 67.554337) + (xy 172.199459 67.533559) + (xy 172.205858 67.514869) + (xy 172.21438 67.495176) + (xy 172.221606 67.449552) + (xy 172.224013 67.437929) + (xy 172.233528 67.400868) + (xy 172.2355 67.393188) + (xy 172.2355 67.371741) + (xy 172.237051 67.352031) + (xy 172.239166 67.338677) + (xy 172.240406 67.330848) + (xy 172.236059 67.284859) + (xy 172.2355 67.273004) + (xy 172.2355 63.142064) (xy 183.263707 63.142064) (xy 183.292825 63.334599) (xy 183.295028 63.340585) @@ -14818,9 +15059,6 @@ (xy 183.467056 63.687474) (xy 183.533485 63.757721) (xy 183.596466 63.824322) - (xy 183.601696 63.827984) - (xy 183.601697 63.827985) - (xy 183.684737 63.88613) (xy 183.755975 63.936011) (xy 183.761838 63.938548) (xy 183.928825 64.01081) @@ -14841,7 +15079,7 @@ (xy 184.599451 63.982444) (xy 184.599456 63.982442) (xy 184.605541 63.980535) - (xy 184.690696 63.933332) + (xy 184.692475 63.932346) (xy 184.770271 63.889223) (xy 184.770274 63.889221) (xy 184.77585 63.88613) @@ -14849,7 +15087,7 @@ (xy 184.780695 63.881978) (xy 184.918855 63.76356) (xy 184.923698 63.759409) - (xy 184.932622 63.747905) + (xy 184.930247 63.750967) (xy 185.020975 63.634001) (xy 185.043046 63.605547) (xy 185.049148 63.593148) @@ -14859,7 +15097,7 @@ (xy 185.176492 63.248575) (xy 185.176492 63.248572) (xy 185.178102 63.242393) - (xy 185.183694 63.135683) + (xy 185.183734 63.134926) (xy 185.187959 63.054317) (xy 185.187959 63.054313) (xy 185.188293 63.047936) @@ -14901,7 +15139,7 @@ (xy 183.67615 62.30387) (xy 183.671309 62.308019) (xy 183.671305 62.308022) - (xy 183.574254 62.391205) + (xy 183.567823 62.396717) (xy 183.528302 62.430591) (xy 183.408954 62.584453) (xy 183.406138 62.590176) @@ -14915,8 +15153,8 @@ (xy 183.271685 62.989836) (xy 183.265205 63.113489) (xy 183.263707 63.142064) - (xy 172.2405 63.142064) - (xy 172.2405 60.142064) + (xy 172.2355 63.142064) + (xy 172.2355 60.142064) (xy 183.263707 60.142064) (xy 183.292825 60.334599) (xy 183.295028 60.340585) @@ -15034,10 +15272,10 @@ (xy 183.272302 59.978069) (xy 183.26443 60.128277) (xy 183.263707 60.142064) - (xy 172.2405 60.142064) - (xy 172.2405 59.343206) - (xy 172.260502 59.275085) - (xy 172.272864 59.258896) + (xy 172.2355 60.142064) + (xy 172.2355 59.348759) + (xy 172.255502 59.280638) + (xy 172.267864 59.264449) (xy 172.311621 59.215852) (xy 172.311622 59.215851) (xy 172.31604 59.210944) @@ -15088,13 +15326,13 @@ (xy 170.83796 59.210944) (xy 170.842378 59.215851) (xy 170.842379 59.215852) - (xy 170.881136 59.258896) - (xy 170.911854 59.322903) - (xy 170.9135 59.343206) - (xy 170.9135 60.6875) - (xy 170.893498 60.755621) - (xy 170.839842 60.802114) - (xy 170.7875 60.8135) + (xy 170.886136 59.264449) + (xy 170.916854 59.328456) + (xy 170.9185 59.348759) + (xy 170.9185 60.6875) + (xy 170.898498 60.755621) + (xy 170.844842 60.802114) + (xy 170.7925 60.8135) (xy 170.719513 60.8135) (xy 170.713061 60.814872) (xy 170.713056 60.814872) @@ -15127,17 +15365,17 @@ (xy 169.980473 62.093556) (xy 169.983776 62.099278) (xy 169.983777 62.099279) - (xy 170.066961 62.243357) + (xy 170.005267 62.1365) (xy 170.07596 62.258944) - (xy 170.112844 62.299908) - (xy 170.119135 62.306895) - (xy 170.149852 62.370903) - (xy 170.151498 62.391205) - (xy 170.151498 63.760532) - (xy 170.131496 63.828653) - (xy 170.07784 63.875146) - (xy 170.007566 63.88525) - (xy 169.999301 63.883779) + (xy 170.080384 62.263857) + (xy 170.082434 62.266679) + (xy 170.106292 62.333547) + (xy 170.106498 62.340741) + (xy 170.106498 63.750967) + (xy 170.086496 63.819088) + (xy 170.03284 63.865581) + (xy 169.962566 63.875685) + (xy 169.954301 63.874214) (xy 169.900944 63.862872) (xy 169.900939 63.862872) (xy 169.894487 63.8615) @@ -15226,7 +15464,7 @@ (xy 168.400981 59.545968) (xy 168.51986 59.461173) (xy 168.545489 59.435634) - (xy 168.674435 59.307137) + (xy 168.629704 59.351712) (xy 168.678096 59.303489) (xy 168.747031 59.207556) (xy 168.805435 59.126277) @@ -15278,58 +15516,58 @@ (xy 168.930431 55.440702) (xy 168.841354 55.23584) (xy 168.779372 55.14003) - (xy 171.5568 55.14003) - (xy 171.562527 55.14768) - (xy 171.747272 55.260893) - (xy 171.756067 55.265375) - (xy 171.97349 55.355434) - (xy 171.982875 55.358483) - (xy 172.211708 55.413422) - (xy 172.221455 55.414965) - (xy 172.45607 55.43343) - (xy 172.46593 55.43343) - (xy 172.700545 55.414965) - (xy 172.710292 55.413422) - (xy 172.939125 55.358483) - (xy 172.94851 55.355434) - (xy 173.165933 55.265375) - (xy 173.174728 55.260893) - (xy 173.355805 55.149928) - (xy 173.36476 55.14003) - (xy 176.6368 55.14003) - (xy 176.642527 55.14768) - (xy 176.827272 55.260893) - (xy 176.836067 55.265375) - (xy 177.05349 55.355434) - (xy 177.062875 55.358483) - (xy 177.291708 55.413422) - (xy 177.301455 55.414965) - (xy 177.53607 55.43343) - (xy 177.54593 55.43343) - (xy 177.780545 55.414965) - (xy 177.790292 55.413422) - (xy 178.019125 55.358483) - (xy 178.02851 55.355434) - (xy 178.245933 55.265375) - (xy 178.254728 55.260893) - (xy 178.435805 55.149928) - (xy 178.445267 55.13947) - (xy 178.441484 55.130694) - (xy 177.553812 54.243022) - (xy 177.539868 54.235408) - (xy 177.538035 54.235539) - (xy 177.53142 54.23979) - (xy 176.64356 55.12765) - (xy 176.6368 55.14003) - (xy 173.36476 55.14003) - (xy 173.365267 55.13947) - (xy 173.361484 55.130694) - (xy 172.473812 54.243022) - (xy 172.459868 54.235408) - (xy 172.458035 54.235539) - (xy 172.45142 54.23979) - (xy 171.56356 55.12765) - (xy 171.5568 55.14003) + (xy 171.6068 55.14003) + (xy 171.612527 55.14768) + (xy 171.797272 55.260893) + (xy 171.806067 55.265375) + (xy 172.02349 55.355434) + (xy 172.032875 55.358483) + (xy 172.261708 55.413422) + (xy 172.271455 55.414965) + (xy 172.50607 55.43343) + (xy 172.51593 55.43343) + (xy 172.750545 55.414965) + (xy 172.760292 55.413422) + (xy 172.989125 55.358483) + (xy 172.99851 55.355434) + (xy 173.215933 55.265375) + (xy 173.224728 55.260893) + (xy 173.405805 55.149928) + (xy 173.41476 55.14003) + (xy 176.6868 55.14003) + (xy 176.692527 55.14768) + (xy 176.877272 55.260893) + (xy 176.886067 55.265375) + (xy 177.10349 55.355434) + (xy 177.112875 55.358483) + (xy 177.341708 55.413422) + (xy 177.351455 55.414965) + (xy 177.58607 55.43343) + (xy 177.59593 55.43343) + (xy 177.830545 55.414965) + (xy 177.840292 55.413422) + (xy 178.069125 55.358483) + (xy 178.07851 55.355434) + (xy 178.295933 55.265375) + (xy 178.304728 55.260893) + (xy 178.485805 55.149928) + (xy 178.495267 55.13947) + (xy 178.491484 55.130694) + (xy 177.603812 54.243022) + (xy 177.589868 54.235408) + (xy 177.588035 54.235539) + (xy 177.58142 54.23979) + (xy 176.69356 55.12765) + (xy 176.6868 55.14003) + (xy 173.41476 55.14003) + (xy 173.415267 55.13947) + (xy 173.411484 55.130694) + (xy 172.523812 54.243022) + (xy 172.509868 54.235408) + (xy 172.508035 54.235539) + (xy 172.50142 54.23979) + (xy 171.61356 55.12765) + (xy 171.6068 55.14003) (xy 168.779372 55.14003) (xy 168.722822 55.052617) (xy 168.72282 55.052614) @@ -15531,111 +15769,111 @@ (xy 168.805004 54.046019) (xy 168.810315 54.03718) (xy 168.89001 53.87593) - (xy 170.89857 53.87593) - (xy 170.917035 54.110545) - (xy 170.918578 54.120292) - (xy 170.973517 54.349125) - (xy 170.976566 54.35851) - (xy 171.066625 54.575933) - (xy 171.071107 54.584728) - (xy 171.182072 54.765805) - (xy 171.19253 54.775267) - (xy 171.201306 54.771484) - (xy 172.088978 53.883812) - (xy 172.095356 53.872132) - (xy 172.825408 53.872132) - (xy 172.825539 53.873965) - (xy 172.82979 53.88058) - (xy 173.71765 54.76844) - (xy 173.73003 54.7752) - (xy 173.73768 54.769473) - (xy 173.850893 54.584728) - (xy 173.855375 54.575933) - (xy 173.945434 54.35851) - (xy 173.948483 54.349125) - (xy 174.003422 54.120292) - (xy 174.004965 54.110545) - (xy 174.02343 53.87593) - (xy 175.97857 53.87593) - (xy 175.997035 54.110545) - (xy 175.998578 54.120292) - (xy 176.053517 54.349125) - (xy 176.056566 54.35851) - (xy 176.146625 54.575933) - (xy 176.151107 54.584728) - (xy 176.262072 54.765805) - (xy 176.27253 54.775267) - (xy 176.281306 54.771484) - (xy 177.168978 53.883812) - (xy 177.175356 53.872132) - (xy 177.905408 53.872132) - (xy 177.905539 53.873965) - (xy 177.90979 53.88058) - (xy 178.79765 54.76844) - (xy 178.81003 54.7752) - (xy 178.81768 54.769473) - (xy 178.930893 54.584728) - (xy 178.935375 54.575933) - (xy 179.025434 54.35851) - (xy 179.028483 54.349125) - (xy 179.083422 54.120292) - (xy 179.084965 54.110545) - (xy 179.10343 53.87593) - (xy 179.10343 53.86607) - (xy 179.084965 53.631455) - (xy 179.083422 53.621708) - (xy 179.028483 53.392875) - (xy 179.025434 53.38349) - (xy 178.935375 53.166067) - (xy 178.930893 53.157272) - (xy 178.819928 52.976195) - (xy 178.80947 52.966733) - (xy 178.800694 52.970516) - (xy 177.913022 53.858188) - (xy 177.905408 53.872132) - (xy 177.175356 53.872132) - (xy 177.176592 53.869868) - (xy 177.176461 53.868035) - (xy 177.17221 53.86142) - (xy 176.28435 52.97356) - (xy 176.27197 52.9668) - (xy 176.26432 52.972527) - (xy 176.151107 53.157272) - (xy 176.146625 53.166067) - (xy 176.056566 53.38349) - (xy 176.053517 53.392875) - (xy 175.998578 53.621708) - (xy 175.997035 53.631455) - (xy 175.97857 53.86607) - (xy 175.97857 53.87593) - (xy 174.02343 53.87593) - (xy 174.02343 53.86607) - (xy 174.004965 53.631455) - (xy 174.003422 53.621708) - (xy 173.948483 53.392875) - (xy 173.945434 53.38349) - (xy 173.855375 53.166067) - (xy 173.850893 53.157272) - (xy 173.739928 52.976195) - (xy 173.72947 52.966733) - (xy 173.720694 52.970516) - (xy 172.833022 53.858188) - (xy 172.825408 53.872132) - (xy 172.095356 53.872132) - (xy 172.096592 53.869868) - (xy 172.096461 53.868035) - (xy 172.09221 53.86142) - (xy 171.20435 52.97356) - (xy 171.19197 52.9668) - (xy 171.18432 52.972527) - (xy 171.071107 53.157272) - (xy 171.066625 53.166067) - (xy 170.976566 53.38349) - (xy 170.973517 53.392875) - (xy 170.918578 53.621708) - (xy 170.917035 53.631455) - (xy 170.89857 53.86607) - (xy 170.89857 53.87593) + (xy 170.94857 53.87593) + (xy 170.967035 54.110545) + (xy 170.968578 54.120292) + (xy 171.023517 54.349125) + (xy 171.026566 54.35851) + (xy 171.116625 54.575933) + (xy 171.121107 54.584728) + (xy 171.232072 54.765805) + (xy 171.24253 54.775267) + (xy 171.251306 54.771484) + (xy 172.138978 53.883812) + (xy 172.145356 53.872132) + (xy 172.875408 53.872132) + (xy 172.875539 53.873965) + (xy 172.87979 53.88058) + (xy 173.76765 54.76844) + (xy 173.78003 54.7752) + (xy 173.78768 54.769473) + (xy 173.900893 54.584728) + (xy 173.905375 54.575933) + (xy 173.995434 54.35851) + (xy 173.998483 54.349125) + (xy 174.053422 54.120292) + (xy 174.054965 54.110545) + (xy 174.07343 53.87593) + (xy 176.02857 53.87593) + (xy 176.047035 54.110545) + (xy 176.048578 54.120292) + (xy 176.103517 54.349125) + (xy 176.106566 54.35851) + (xy 176.196625 54.575933) + (xy 176.201107 54.584728) + (xy 176.312072 54.765805) + (xy 176.32253 54.775267) + (xy 176.331306 54.771484) + (xy 177.218978 53.883812) + (xy 177.225356 53.872132) + (xy 177.955408 53.872132) + (xy 177.955539 53.873965) + (xy 177.95979 53.88058) + (xy 178.84765 54.76844) + (xy 178.86003 54.7752) + (xy 178.86768 54.769473) + (xy 178.980893 54.584728) + (xy 178.985375 54.575933) + (xy 179.075434 54.35851) + (xy 179.078483 54.349125) + (xy 179.133422 54.120292) + (xy 179.134965 54.110545) + (xy 179.15343 53.87593) + (xy 179.15343 53.86607) + (xy 179.134965 53.631455) + (xy 179.133422 53.621708) + (xy 179.078483 53.392875) + (xy 179.075434 53.38349) + (xy 178.985375 53.166067) + (xy 178.980893 53.157272) + (xy 178.869928 52.976195) + (xy 178.85947 52.966733) + (xy 178.850694 52.970516) + (xy 177.963022 53.858188) + (xy 177.955408 53.872132) + (xy 177.225356 53.872132) + (xy 177.226592 53.869868) + (xy 177.226461 53.868035) + (xy 177.22221 53.86142) + (xy 176.33435 52.97356) + (xy 176.32197 52.9668) + (xy 176.31432 52.972527) + (xy 176.201107 53.157272) + (xy 176.196625 53.166067) + (xy 176.106566 53.38349) + (xy 176.103517 53.392875) + (xy 176.048578 53.621708) + (xy 176.047035 53.631455) + (xy 176.02857 53.86607) + (xy 176.02857 53.87593) + (xy 174.07343 53.87593) + (xy 174.07343 53.86607) + (xy 174.054965 53.631455) + (xy 174.053422 53.621708) + (xy 173.998483 53.392875) + (xy 173.995434 53.38349) + (xy 173.905375 53.166067) + (xy 173.900893 53.157272) + (xy 173.789928 52.976195) + (xy 173.77947 52.966733) + (xy 173.770694 52.970516) + (xy 172.883022 53.858188) + (xy 172.875408 53.872132) + (xy 172.145356 53.872132) + (xy 172.146592 53.869868) + (xy 172.146461 53.868035) + (xy 172.14221 53.86142) + (xy 171.25435 52.97356) + (xy 171.24197 52.9668) + (xy 171.23432 52.972527) + (xy 171.121107 53.157272) + (xy 171.116625 53.166067) + (xy 171.026566 53.38349) + (xy 171.023517 53.392875) + (xy 170.968578 53.621708) + (xy 170.967035 53.631455) + (xy 170.94857 53.86607) + (xy 170.94857 53.87593) (xy 168.89001 53.87593) (xy 168.90467 53.846267) (xy 168.908469 53.836672) @@ -15652,58 +15890,58 @@ (xy 168.842972 52.700814) (xy 168.838105 52.691739) (xy 168.780394 52.60253) - (xy 171.556733 52.60253) - (xy 171.560516 52.611306) - (xy 172.448188 53.498978) - (xy 172.462132 53.506592) - (xy 172.463965 53.506461) - (xy 172.47058 53.50221) - (xy 173.35844 52.61435) - (xy 173.364894 52.60253) - (xy 176.636733 52.60253) - (xy 176.640516 52.611306) - (xy 177.528188 53.498978) - (xy 177.542132 53.506592) - (xy 177.543965 53.506461) - (xy 177.55058 53.50221) - (xy 178.43844 52.61435) - (xy 178.4452 52.60197) - (xy 178.439473 52.59432) - (xy 178.254728 52.481107) - (xy 178.245933 52.476625) - (xy 178.02851 52.386566) - (xy 178.019125 52.383517) - (xy 177.790292 52.328578) - (xy 177.780545 52.327035) - (xy 177.54593 52.30857) - (xy 177.53607 52.30857) - (xy 177.301455 52.327035) - (xy 177.291708 52.328578) - (xy 177.062875 52.383517) - (xy 177.05349 52.386566) - (xy 176.836067 52.476625) - (xy 176.827272 52.481107) - (xy 176.646195 52.592072) - (xy 176.636733 52.60253) - (xy 173.364894 52.60253) - (xy 173.3652 52.60197) - (xy 173.359473 52.59432) - (xy 173.174728 52.481107) - (xy 173.165933 52.476625) - (xy 172.94851 52.386566) - (xy 172.939125 52.383517) - (xy 172.710292 52.328578) - (xy 172.700545 52.327035) - (xy 172.46593 52.30857) - (xy 172.45607 52.30857) - (xy 172.221455 52.327035) - (xy 172.211708 52.328578) - (xy 171.982875 52.383517) - (xy 171.97349 52.386566) - (xy 171.756067 52.476625) - (xy 171.747272 52.481107) - (xy 171.566195 52.592072) - (xy 171.556733 52.60253) + (xy 171.606733 52.60253) + (xy 171.610516 52.611306) + (xy 172.498188 53.498978) + (xy 172.512132 53.506592) + (xy 172.513965 53.506461) + (xy 172.52058 53.50221) + (xy 173.40844 52.61435) + (xy 173.414894 52.60253) + (xy 176.686733 52.60253) + (xy 176.690516 52.611306) + (xy 177.578188 53.498978) + (xy 177.592132 53.506592) + (xy 177.593965 53.506461) + (xy 177.60058 53.50221) + (xy 178.48844 52.61435) + (xy 178.4952 52.60197) + (xy 178.489473 52.59432) + (xy 178.304728 52.481107) + (xy 178.295933 52.476625) + (xy 178.07851 52.386566) + (xy 178.069125 52.383517) + (xy 177.840292 52.328578) + (xy 177.830545 52.327035) + (xy 177.59593 52.30857) + (xy 177.58607 52.30857) + (xy 177.351455 52.327035) + (xy 177.341708 52.328578) + (xy 177.112875 52.383517) + (xy 177.10349 52.386566) + (xy 176.886067 52.476625) + (xy 176.877272 52.481107) + (xy 176.696195 52.592072) + (xy 176.686733 52.60253) + (xy 173.414894 52.60253) + (xy 173.4152 52.60197) + (xy 173.409473 52.59432) + (xy 173.224728 52.481107) + (xy 173.215933 52.476625) + (xy 172.99851 52.386566) + (xy 172.989125 52.383517) + (xy 172.760292 52.328578) + (xy 172.750545 52.327035) + (xy 172.51593 52.30857) + (xy 172.50607 52.30857) + (xy 172.271455 52.327035) + (xy 172.261708 52.328578) + (xy 172.032875 52.383517) + (xy 172.02349 52.386566) + (xy 171.806067 52.476625) + (xy 171.797272 52.481107) + (xy 171.616195 52.592072) + (xy 171.606733 52.60253) (xy 168.780394 52.60253) (xy 168.773063 52.591197) (xy 168.762377 52.581995) @@ -15863,58 +16101,58 @@ (xy 168.842972 50.160814) (xy 168.838105 50.151739) (xy 168.778777 50.06003) - (xy 171.5568 50.06003) - (xy 171.562527 50.06768) - (xy 171.747272 50.180893) - (xy 171.756067 50.185375) - (xy 171.97349 50.275434) - (xy 171.982875 50.278483) - (xy 172.211708 50.333422) - (xy 172.221455 50.334965) - (xy 172.45607 50.35343) - (xy 172.46593 50.35343) - (xy 172.700545 50.334965) - (xy 172.710292 50.333422) - (xy 172.939125 50.278483) - (xy 172.94851 50.275434) - (xy 173.165933 50.185375) - (xy 173.174728 50.180893) - (xy 173.355805 50.069928) - (xy 173.36476 50.06003) - (xy 176.6368 50.06003) - (xy 176.642527 50.06768) - (xy 176.827272 50.180893) - (xy 176.836067 50.185375) - (xy 177.05349 50.275434) - (xy 177.062875 50.278483) - (xy 177.291708 50.333422) - (xy 177.301455 50.334965) - (xy 177.53607 50.35343) - (xy 177.54593 50.35343) - (xy 177.780545 50.334965) - (xy 177.790292 50.333422) - (xy 178.019125 50.278483) - (xy 178.02851 50.275434) - (xy 178.245933 50.185375) - (xy 178.254728 50.180893) - (xy 178.435805 50.069928) - (xy 178.445267 50.05947) - (xy 178.441484 50.050694) - (xy 177.553812 49.163022) - (xy 177.539868 49.155408) - (xy 177.538035 49.155539) - (xy 177.53142 49.15979) - (xy 176.64356 50.04765) - (xy 176.6368 50.06003) - (xy 173.36476 50.06003) - (xy 173.365267 50.05947) - (xy 173.361484 50.050694) - (xy 172.473812 49.163022) - (xy 172.459868 49.155408) - (xy 172.458035 49.155539) - (xy 172.45142 49.15979) - (xy 171.56356 50.04765) - (xy 171.5568 50.06003) + (xy 171.6068 50.06003) + (xy 171.612527 50.06768) + (xy 171.797272 50.180893) + (xy 171.806067 50.185375) + (xy 172.02349 50.275434) + (xy 172.032875 50.278483) + (xy 172.261708 50.333422) + (xy 172.271455 50.334965) + (xy 172.50607 50.35343) + (xy 172.51593 50.35343) + (xy 172.750545 50.334965) + (xy 172.760292 50.333422) + (xy 172.989125 50.278483) + (xy 172.99851 50.275434) + (xy 173.215933 50.185375) + (xy 173.224728 50.180893) + (xy 173.405805 50.069928) + (xy 173.41476 50.06003) + (xy 176.6868 50.06003) + (xy 176.692527 50.06768) + (xy 176.877272 50.180893) + (xy 176.886067 50.185375) + (xy 177.10349 50.275434) + (xy 177.112875 50.278483) + (xy 177.341708 50.333422) + (xy 177.351455 50.334965) + (xy 177.58607 50.35343) + (xy 177.59593 50.35343) + (xy 177.830545 50.334965) + (xy 177.840292 50.333422) + (xy 178.069125 50.278483) + (xy 178.07851 50.275434) + (xy 178.295933 50.185375) + (xy 178.304728 50.180893) + (xy 178.485805 50.069928) + (xy 178.495267 50.05947) + (xy 178.491484 50.050694) + (xy 177.603812 49.163022) + (xy 177.589868 49.155408) + (xy 177.588035 49.155539) + (xy 177.58142 49.15979) + (xy 176.69356 50.04765) + (xy 176.6868 50.06003) + (xy 173.41476 50.06003) + (xy 173.415267 50.05947) + (xy 173.411484 50.050694) + (xy 172.523812 49.163022) + (xy 172.509868 49.155408) + (xy 172.508035 49.155539) + (xy 172.50142 49.15979) + (xy 171.61356 50.04765) + (xy 171.6068 50.06003) (xy 168.778777 50.06003) (xy 168.773063 50.051197) (xy 168.762377 50.041995) @@ -16155,7 +16393,7 @@ (xy 136.06375 75.026179) (xy 136.006914 74.983632) (xy 135.982206 74.918447) - (xy 135.974069 74.819476) + (xy 135.979213 74.882042) (xy 135.964852 74.707361) (xy 135.910431 74.490702) (xy 135.821354 74.28584) @@ -16243,16 +16481,16 @@ (xy 135.885136 67.816453) (xy 135.885137 67.816451) (xy 135.88743 67.811811) - (xy 135.934419 67.657153) - (xy 135.950865 67.603023) - (xy 135.950865 67.603021) (xy 135.95237 67.598069) (xy 135.981529 67.37659) + (xy 135.981611 67.37324) + (xy 135.983074 67.313365) + (xy 135.983074 67.313361) (xy 135.983156 67.31) (xy 135.964852 67.087361) (xy 135.910431 66.870702) (xy 135.821354 66.66584) - (xy 135.743972 66.546225) + (xy 135.74397 66.546223) (xy 135.702822 66.482617) (xy 135.70282 66.482614) (xy 135.700014 66.478277) @@ -16562,111 +16800,111 @@ (xy 125.614886 49.30001) (xy 125.6035 49.247668) (xy 125.6035 48.79593) - (xy 170.89857 48.79593) - (xy 170.917035 49.030545) - (xy 170.918578 49.040292) - (xy 170.973517 49.269125) - (xy 170.976566 49.27851) - (xy 171.066625 49.495933) - (xy 171.071107 49.504728) - (xy 171.182072 49.685805) - (xy 171.19253 49.695267) - (xy 171.201306 49.691484) - (xy 172.088978 48.803812) - (xy 172.095356 48.792132) - (xy 172.825408 48.792132) - (xy 172.825539 48.793965) - (xy 172.82979 48.80058) - (xy 173.71765 49.68844) - (xy 173.73003 49.6952) - (xy 173.73768 49.689473) - (xy 173.850893 49.504728) - (xy 173.855375 49.495933) - (xy 173.945434 49.27851) - (xy 173.948483 49.269125) - (xy 174.003422 49.040292) - (xy 174.004965 49.030545) - (xy 174.02343 48.79593) - (xy 175.97857 48.79593) - (xy 175.997035 49.030545) - (xy 175.998578 49.040292) - (xy 176.053517 49.269125) - (xy 176.056566 49.27851) - (xy 176.146625 49.495933) - (xy 176.151107 49.504728) - (xy 176.262072 49.685805) - (xy 176.27253 49.695267) - (xy 176.281306 49.691484) - (xy 177.168978 48.803812) - (xy 177.175356 48.792132) - (xy 177.905408 48.792132) - (xy 177.905539 48.793965) - (xy 177.90979 48.80058) - (xy 178.79765 49.68844) - (xy 178.81003 49.6952) - (xy 178.81768 49.689473) - (xy 178.930893 49.504728) - (xy 178.935375 49.495933) - (xy 179.025434 49.27851) - (xy 179.028483 49.269125) - (xy 179.083422 49.040292) - (xy 179.084965 49.030545) - (xy 179.10343 48.79593) - (xy 179.10343 48.78607) - (xy 179.084965 48.551455) - (xy 179.083422 48.541708) - (xy 179.028483 48.312875) - (xy 179.025434 48.30349) - (xy 178.935375 48.086067) - (xy 178.930893 48.077272) - (xy 178.819928 47.896195) - (xy 178.80947 47.886733) - (xy 178.800694 47.890516) - (xy 177.913022 48.778188) - (xy 177.905408 48.792132) - (xy 177.175356 48.792132) - (xy 177.176592 48.789868) - (xy 177.176461 48.788035) - (xy 177.17221 48.78142) - (xy 176.28435 47.89356) - (xy 176.27197 47.8868) - (xy 176.26432 47.892527) - (xy 176.151107 48.077272) - (xy 176.146625 48.086067) - (xy 176.056566 48.30349) - (xy 176.053517 48.312875) - (xy 175.998578 48.541708) - (xy 175.997035 48.551455) - (xy 175.97857 48.78607) - (xy 175.97857 48.79593) - (xy 174.02343 48.79593) - (xy 174.02343 48.78607) - (xy 174.004965 48.551455) - (xy 174.003422 48.541708) - (xy 173.948483 48.312875) - (xy 173.945434 48.30349) - (xy 173.855375 48.086067) - (xy 173.850893 48.077272) - (xy 173.739928 47.896195) - (xy 173.72947 47.886733) - (xy 173.720694 47.890516) - (xy 172.833022 48.778188) - (xy 172.825408 48.792132) - (xy 172.095356 48.792132) - (xy 172.096592 48.789868) - (xy 172.096461 48.788035) - (xy 172.09221 48.78142) - (xy 171.20435 47.89356) - (xy 171.19197 47.8868) - (xy 171.18432 47.892527) - (xy 171.071107 48.077272) - (xy 171.066625 48.086067) - (xy 170.976566 48.30349) - (xy 170.973517 48.312875) - (xy 170.918578 48.541708) - (xy 170.917035 48.551455) - (xy 170.89857 48.78607) - (xy 170.89857 48.79593) + (xy 170.94857 48.79593) + (xy 170.967035 49.030545) + (xy 170.968578 49.040292) + (xy 171.023517 49.269125) + (xy 171.026566 49.27851) + (xy 171.116625 49.495933) + (xy 171.121107 49.504728) + (xy 171.232072 49.685805) + (xy 171.24253 49.695267) + (xy 171.251306 49.691484) + (xy 172.138978 48.803812) + (xy 172.145356 48.792132) + (xy 172.875408 48.792132) + (xy 172.875539 48.793965) + (xy 172.87979 48.80058) + (xy 173.76765 49.68844) + (xy 173.78003 49.6952) + (xy 173.78768 49.689473) + (xy 173.900893 49.504728) + (xy 173.905375 49.495933) + (xy 173.995434 49.27851) + (xy 173.998483 49.269125) + (xy 174.053422 49.040292) + (xy 174.054965 49.030545) + (xy 174.07343 48.79593) + (xy 176.02857 48.79593) + (xy 176.047035 49.030545) + (xy 176.048578 49.040292) + (xy 176.103517 49.269125) + (xy 176.106566 49.27851) + (xy 176.196625 49.495933) + (xy 176.201107 49.504728) + (xy 176.312072 49.685805) + (xy 176.32253 49.695267) + (xy 176.331306 49.691484) + (xy 177.218978 48.803812) + (xy 177.225356 48.792132) + (xy 177.955408 48.792132) + (xy 177.955539 48.793965) + (xy 177.95979 48.80058) + (xy 178.84765 49.68844) + (xy 178.86003 49.6952) + (xy 178.86768 49.689473) + (xy 178.980893 49.504728) + (xy 178.985375 49.495933) + (xy 179.075434 49.27851) + (xy 179.078483 49.269125) + (xy 179.133422 49.040292) + (xy 179.134965 49.030545) + (xy 179.15343 48.79593) + (xy 179.15343 48.78607) + (xy 179.134965 48.551455) + (xy 179.133422 48.541708) + (xy 179.078483 48.312875) + (xy 179.075434 48.30349) + (xy 178.985375 48.086067) + (xy 178.980893 48.077272) + (xy 178.869928 47.896195) + (xy 178.85947 47.886733) + (xy 178.850694 47.890516) + (xy 177.963022 48.778188) + (xy 177.955408 48.792132) + (xy 177.225356 48.792132) + (xy 177.226592 48.789868) + (xy 177.226461 48.788035) + (xy 177.22221 48.78142) + (xy 176.33435 47.89356) + (xy 176.32197 47.8868) + (xy 176.31432 47.892527) + (xy 176.201107 48.077272) + (xy 176.196625 48.086067) + (xy 176.106566 48.30349) + (xy 176.103517 48.312875) + (xy 176.048578 48.541708) + (xy 176.047035 48.551455) + (xy 176.02857 48.78607) + (xy 176.02857 48.79593) + (xy 174.07343 48.79593) + (xy 174.07343 48.78607) + (xy 174.054965 48.551455) + (xy 174.053422 48.541708) + (xy 173.998483 48.312875) + (xy 173.995434 48.30349) + (xy 173.905375 48.086067) + (xy 173.900893 48.077272) + (xy 173.789928 47.896195) + (xy 173.77947 47.886733) + (xy 173.770694 47.890516) + (xy 172.883022 48.778188) + (xy 172.875408 48.792132) + (xy 172.145356 48.792132) + (xy 172.146592 48.789868) + (xy 172.146461 48.788035) + (xy 172.14221 48.78142) + (xy 171.25435 47.89356) + (xy 171.24197 47.8868) + (xy 171.23432 47.892527) + (xy 171.121107 48.077272) + (xy 171.116625 48.086067) + (xy 171.026566 48.30349) + (xy 171.023517 48.312875) + (xy 170.968578 48.541708) + (xy 170.967035 48.551455) + (xy 170.94857 48.78607) + (xy 170.94857 48.79593) (xy 125.6035 48.79593) (xy 125.6035 48.31325) (xy 125.605246 48.292345) @@ -16700,7 +16938,7 @@ (xy 126.384059 47.500378) (xy 126.390286 47.499564) (xy 126.406621 47.4985) - (xy 171.47552 47.4985) + (xy 171.52552 47.4985) ) ) (filled_polygon @@ -17086,8 +17324,6 @@ (xy 161.698379 68.359852) (xy 161.817325 68.491955) (xy 161.821747 68.496866) - (xy 161.914045 68.563925) - (xy 161.964841 68.60083) (xy 161.976248 68.609118) (xy 161.982276 68.611802) (xy 161.982278 68.611803) @@ -17182,9 +17418,9 @@ (xy 166.913607 72.506507) (xy 166.909474 72.50961) (xy 166.909471 72.509612) - (xy 166.749 72.630097) + (xy 166.7391 72.63753) (xy 166.734965 72.640635) - (xy 166.718218 72.65816) + (xy 166.716605 72.659848) (xy 166.589748 72.792596) (xy 166.580629 72.802138) (xy 166.454743 72.98668) @@ -17212,9 +17448,14 @@ (xy 166.913607 75.046507) (xy 166.909474 75.04961) (xy 166.909471 75.049612) - (xy 166.745648 75.172614) + (xy 166.7391 75.17753) (xy 166.734965 75.180635) + (xy 166.731393 75.184373) + (xy 166.589812 75.332529) (xy 166.580629 75.342138) + (xy 166.577715 75.34641) + (xy 166.577714 75.346411) + (xy 166.569424 75.358564) (xy 166.454743 75.52668) (xy 166.409349 75.624473) (xy 166.387249 75.672085) @@ -17283,11 +17524,8 @@ (xy 166.7391 80.25753) (xy 166.734965 80.260635) (xy 166.713544 80.283051) - (xy 166.589748 80.412596) + (xy 166.589554 80.412799) (xy 166.580629 80.422138) - (xy 166.577715 80.42641) - (xy 166.577714 80.426411) - (xy 166.52097 80.509595) (xy 166.454743 80.60668) (xy 166.360688 80.809305) (xy 166.300989 81.02457) @@ -17301,8 +17539,8 @@ (xy 166.311239 81.563469) (xy 166.339222 81.687639) (xy 166.423266 81.894616) - (xy 166.462415 81.958502) - (xy 166.527371 82.0645) + (xy 166.469825 81.970594) + (xy 166.525475 82.061406) (xy 166.539987 82.085088) (xy 166.68625 82.253938) (xy 166.858126 82.396632) @@ -17315,7 +17553,7 @@ (xy 166.913607 82.666507) (xy 166.909474 82.66961) (xy 166.909471 82.669612) - (xy 166.7391 82.79753) + (xy 166.759065 82.78254) (xy 166.734965 82.800635) (xy 166.694458 82.843023) (xy 166.589748 82.952596) @@ -17328,14 +17566,14 @@ (xy 166.277251 83.786695) (xy 166.277548 83.791848) (xy 166.277548 83.791851) - (xy 166.289744 84.003365) + (xy 166.282709 83.881364) (xy 166.29011 84.009715) (xy 166.291247 84.014761) (xy 166.291248 84.014767) (xy 166.311239 84.103469) (xy 166.339222 84.227639) (xy 166.423266 84.434616) - (xy 166.472285 84.514608) + (xy 166.457815 84.490995) (xy 166.525475 84.601406) (xy 166.539987 84.625088) (xy 166.68625 84.793938) @@ -17363,7 +17601,7 @@ (xy 166.277251 86.326695) (xy 166.277548 86.331848) (xy 166.277548 86.331851) - (xy 166.288563 86.522892) + (xy 166.287779 86.509289) (xy 166.29011 86.549715) (xy 166.291247 86.554761) (xy 166.291248 86.554767) @@ -17587,7 +17825,6 @@ (xy 155.007707 67.800972) (xy 154.999012 67.783224) (xy 154.991552 67.764383) - (xy 154.986355 67.757229) (xy 154.965564 67.728613) (xy 154.959048 67.718693) (xy 154.94058 67.687465) @@ -17595,6 +17832,7 @@ (xy 154.936542 67.680638) (xy 154.922221 67.666317) (xy 154.90938 67.651283) + (xy 154.902131 67.641306) (xy 154.897472 67.634893) (xy 154.863395 67.606702) (xy 154.854616 67.598712) @@ -17641,7 +17879,7 @@ (xy 156.196739 66.068261) (xy 156.197852 66.069095) (xy 156.197858 66.0691) - (xy 156.204283 66.073915) + (xy 156.240552 66.101097) (xy 156.313295 66.155615) (xy 156.449684 66.206745) (xy 156.511866 66.2135) @@ -17673,11 +17911,14 @@ (xy 158.984668 63.400896) (xy 159.023831 63.296426) (xy 159.031745 63.275316) - (xy 159.034599 63.249046) - (xy 159.061842 63.183484) - (xy 159.120205 63.143058) - (xy 159.133665 63.139408) - (xy 159.154121 63.13506) + (xy 159.032598 63.26746) + (xy 159.034425 63.259778) + (xy 159.035728 63.260088) + (xy 159.059816 63.202114) + (xy 159.068743 63.192188) + (xy 159.091853 63.169078) + (xy 159.154751 63.134926) + (xy 159.170909 63.131491) (xy 159.307608 63.102435) (xy 159.390072 63.06572) (xy 159.476042 63.027444) @@ -18207,18 +18448,15 @@ (xy 130.73011 80.199715) (xy 130.731247 80.204761) (xy 130.731248 80.204767) - (xy 130.751096 80.292837) - (xy 130.779222 80.417639) - (xy 130.781166 80.422426) - (xy 130.787528 80.438094) - (xy 130.794625 80.508735) - (xy 130.762404 80.571999) - (xy 130.701095 80.6078) - (xy 130.670786 80.6115) - (xy 129.3745 80.6115) - (xy 129.306379 80.591498) - (xy 129.259886 80.537842) - (xy 129.2485 80.4855) + (xy 130.778131 80.412799) + (xy 130.773595 80.483651) + (xy 130.731473 80.540802) + (xy 130.66514 80.566108) + (xy 130.655214 80.5665) + (xy 129.3745 80.5665) + (xy 129.306379 80.546498) + (xy 129.259886 80.492842) + (xy 129.2485 80.4405) (xy 129.2485 80.303533) (xy 129.241745 80.241351) (xy 129.190615 80.104962) @@ -18271,55 +18509,6 @@ (xy 130.681527 76.8335) ) ) - (filled_polygon - (layer "B.Cu") - (pts - (xy 133.432026 78.145144) - (xy 133.459875 78.176994) - (xy 133.519987 78.275088) - (xy 133.66625 78.443938) - (xy 133.838126 78.586632) - (xy 133.911445 78.629476) - (xy 133.911955 78.629774) - (xy 133.960679 78.681412) - (xy 133.97375 78.751195) - (xy 133.947019 78.816967) - (xy 133.906562 78.850327) - (xy 133.898457 78.854546) - (xy 133.889738 78.860036) - (xy 133.719433 78.987905) - (xy 133.711726 78.994748) - (xy 133.56459 79.148717) - (xy 133.558109 79.156722) - (xy 133.453498 79.310074) - (xy 133.398587 79.355076) - (xy 133.328062 79.363247) - (xy 133.264315 79.331993) - (xy 133.243618 79.307509) - (xy 133.162822 79.182617) - (xy 133.16282 79.182614) - (xy 133.160014 79.178277) - (xy 133.00967 79.013051) - (xy 133.005619 79.009852) - (xy 133.005615 79.009848) - (xy 132.838414 78.8778) - (xy 132.83841 78.877798) - (xy 132.834359 78.874598) - (xy 132.793053 78.851796) - (xy 132.743084 78.801364) - (xy 132.728312 78.731921) - (xy 132.753428 78.665516) - (xy 132.78078 78.638909) - (xy 132.824603 78.60765) - (xy 132.95986 78.511173) - (xy 133.118096 78.353489) - (xy 133.12671 78.341502) - (xy 133.248453 78.172077) - (xy 133.249776 78.173028) - (xy 133.296645 78.129857) - (xy 133.36658 78.117625) - ) - ) (filled_polygon (layer "B.Cu") (pts @@ -18369,6 +18558,55 @@ (xy 143.52658 78.117625) ) ) + (filled_polygon + (layer "B.Cu") + (pts + (xy 133.432026 78.145144) + (xy 133.459875 78.176994) + (xy 133.519987 78.275088) + (xy 133.66625 78.443938) + (xy 133.838126 78.586632) + (xy 133.911445 78.629476) + (xy 133.911955 78.629774) + (xy 133.960679 78.681412) + (xy 133.97375 78.751195) + (xy 133.947019 78.816967) + (xy 133.906562 78.850327) + (xy 133.898457 78.854546) + (xy 133.889738 78.860036) + (xy 133.719433 78.987905) + (xy 133.711726 78.994748) + (xy 133.56459 79.148717) + (xy 133.558109 79.156722) + (xy 133.453498 79.310074) + (xy 133.398587 79.355076) + (xy 133.328062 79.363247) + (xy 133.264315 79.331993) + (xy 133.243618 79.307509) + (xy 133.162822 79.182617) + (xy 133.16282 79.182614) + (xy 133.160014 79.178277) + (xy 133.00967 79.013051) + (xy 133.005619 79.009852) + (xy 133.005615 79.009848) + (xy 132.838414 78.8778) + (xy 132.83841 78.877798) + (xy 132.834359 78.874598) + (xy 132.793053 78.851796) + (xy 132.743084 78.801364) + (xy 132.728312 78.731921) + (xy 132.753428 78.665516) + (xy 132.78078 78.638909) + (xy 132.824603 78.60765) + (xy 132.95986 78.511173) + (xy 133.118096 78.353489) + (xy 133.12671 78.341502) + (xy 133.248453 78.172077) + (xy 133.249776 78.173028) + (xy 133.296645 78.129857) + (xy 133.36658 78.117625) + ) + ) (filled_polygon (layer "B.Cu") (pts @@ -18457,7 +18695,7 @@ (xy 140.877251 62.196695) (xy 140.877548 62.201848) (xy 140.877548 62.201851) - (xy 140.888466 62.391205) + (xy 140.888784 62.396717) (xy 140.89011 62.419715) (xy 140.891247 62.424761) (xy 140.891248 62.424767) @@ -18524,9 +18762,6 @@ (xy 141.269346 66.359301) (xy 141.189748 66.442596) (xy 141.180629 66.452138) - (xy 141.17772 66.456403) - (xy 141.177714 66.456411) - (xy 141.159838 66.482617) (xy 141.054743 66.63668) (xy 141.036259 66.6765) (xy 140.963245 66.833797) @@ -18535,13 +18770,13 @@ (xy 140.877251 67.276695) (xy 140.877548 67.281848) (xy 140.877548 67.281851) - (xy 140.883011 67.37659) + (xy 140.886708 67.440721) (xy 140.89011 67.499715) (xy 140.891247 67.504761) (xy 140.891248 67.504767) (xy 140.911119 67.592939) (xy 140.939222 67.717639) - (xy 140.983809 67.827444) + (xy 140.983643 67.827036) (xy 141.020964 67.918946) (xy 141.023266 67.924616) (xy 141.070298 68.001365) @@ -18794,6 +19029,135 @@ (xy 130.682062 74.2935) ) ) + (filled_polygon + (layer "B.Cu") + (pts + (xy 146.24625 65.110814) + (xy 146.281932 65.135838) + (xy 147.030595 65.884501) + (xy 147.064621 65.946813) + (xy 147.0675 65.973596) + (xy 147.0675 67.496476) + (xy 147.047498 67.564597) + (xy 147.035142 67.580779) + (xy 146.96196 67.662056) + (xy 146.920536 67.733804) + (xy 146.871691 67.818407) + (xy 146.866473 67.827444) + (xy 146.807458 68.009072) + (xy 146.787496 68.199) + (xy 146.807458 68.388928) + (xy 146.866473 68.570556) + (xy 146.869776 68.576278) + (xy 146.869777 68.576279) + (xy 146.903686 68.63501) + (xy 146.96196 68.735944) + (xy 146.966378 68.740851) + (xy 146.966379 68.740852) + (xy 147.06485 68.850215) + (xy 147.089747 68.877866) + (xy 147.188843 68.949864) + (xy 147.228255 68.978498) + (xy 147.244248 68.990118) + (xy 147.250276 68.992802) + (xy 147.250278 68.992803) + (xy 147.406271 69.062255) + (xy 147.418712 69.067794) + (xy 147.512112 69.087647) + (xy 147.599056 69.106128) + (xy 147.599061 69.106128) + (xy 147.605513 69.1075) + (xy 147.796487 69.1075) + (xy 147.802939 69.106128) + (xy 147.802944 69.106128) + (xy 147.931303 69.078844) + (xy 148.002094 69.084246) + (xy 148.058726 69.127063) + (xy 148.08322 69.193701) + (xy 148.0835 69.202091) + (xy 148.0835 72.461405) + (xy 148.063498 72.529526) + (xy 148.009842 72.576019) + (xy 147.939568 72.586123) + (xy 147.874988 72.556629) + (xy 147.868405 72.5505) + (xy 146.045652 70.727747) + (xy 146.038112 70.719461) + (xy 146.034 70.712982) + (xy 145.989344 70.671048) + (xy 145.953379 70.609836) + (xy 145.956216 70.538897) + (xy 145.96264 70.523371) + (xy 145.964312 70.519989) + (xy 146.04743 70.351811) + (xy 146.11237 70.138069) + (xy 146.141529 69.91659) + (xy 146.143156 69.85) + (xy 146.124852 69.627361) + (xy 146.070431 69.410702) + (xy 145.981354 69.20584) + (xy 145.913146 69.100407) + (xy 145.862822 69.022617) + (xy 145.86282 69.022614) + (xy 145.860014 69.018277) + (xy 145.70967 68.853051) + (xy 145.705619 68.849852) + (xy 145.705615 68.849848) + (xy 145.538414 68.7178) + (xy 145.53841 68.717798) + (xy 145.534359 68.714598) + (xy 145.493053 68.691796) + (xy 145.443084 68.641364) + (xy 145.428312 68.571921) + (xy 145.453428 68.505516) + (xy 145.48078 68.478909) + (xy 145.524603 68.44765) + (xy 145.65986 68.351173) + (xy 145.818096 68.193489) + (xy 145.877594 68.110689) + (xy 145.945435 68.016277) + (xy 145.948453 68.012077) + (xy 145.968206 67.972111) + (xy 146.045136 67.816453) + (xy 146.045137 67.816451) + (xy 146.04743 67.811811) + (xy 146.11237 67.598069) + (xy 146.141529 67.37659) + (xy 146.141611 67.37324) + (xy 146.143074 67.313365) + (xy 146.143074 67.313361) + (xy 146.143156 67.31) + (xy 146.124852 67.087361) + (xy 146.070431 66.870702) + (xy 145.981354 66.66584) + (xy 145.90397 66.546223) + (xy 145.862822 66.482617) + (xy 145.86282 66.482614) + (xy 145.860014 66.478277) + (xy 145.70967 66.313051) + (xy 145.705619 66.309852) + (xy 145.705615 66.309848) + (xy 145.538414 66.1778) + (xy 145.53841 66.177798) + (xy 145.534359 66.174598) + (xy 145.492569 66.151529) + (xy 145.442598 66.101097) + (xy 145.427826 66.031654) + (xy 145.452942 65.965248) + (xy 145.480294 65.938641) + (xy 145.655328 65.813792) + (xy 145.6632 65.807139) + (xy 145.814052 65.656812) + (xy 145.82073 65.648965) + (xy 145.945003 65.47602) + (xy 145.950313 65.467183) + (xy 146.04467 65.276267) + (xy 146.048466 65.26668) + (xy 146.072278 65.188305) + (xy 146.111219 65.12894) + (xy 146.176073 65.100053) + ) + ) (filled_polygon (layer "B.Cu") (pts @@ -18932,7 +19296,7 @@ (xy 142.984603 65.90765) (xy 143.11986 65.811173) (xy 143.152675 65.778473) - (xy 143.254374 65.677128) + (xy 143.274435 65.657137) (xy 143.278096 65.653489) (xy 143.28671 65.641502) (xy 143.408453 65.472077) @@ -18981,7 +19345,7 @@ (xy 130.717251 62.196695) (xy 130.717548 62.201848) (xy 130.717548 62.201851) - (xy 130.728466 62.391205) + (xy 130.728784 62.396717) (xy 130.73011 62.419715) (xy 130.731247 62.424761) (xy 130.731248 62.424767) diff --git a/kicad/fp-info-cache b/kicad/fp-info-cache index 19d4715..bc95a36 100644 --- a/kicad/fp-info-cache +++ b/kicad/fp-info-cache @@ -1,960 +1,20063 @@ -219820015869630 -Symbol -CE-Logo_8.5x6mm_SilkScreen -CE marking -Logo CE certification 0 -0 -0 -Symbol -CE-Logo_11.2x8mm_SilkScreen -CE marking -Logo CE certification -0 -0 -0 -Symbol -CE-Logo_16.8x12mm_SilkScreen -CE marking -Logo CE certification -0 -0 -0 -Symbol -CE-Logo_28x20mm_SilkScreen -CE marking -Logo CE certification -0 -0 -0 -Symbol -CE-Logo_42x30mm_SilkScreen -CE marking -Logo CE certification -0 -0 -0 -Symbol -CE-Logo_56.1x40mm_SilkScreen -CE marking -Logo CE certification -0 -0 -0 -Symbol -ESD-Logo_6.6x6mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -ESD-Logo_8.9x8mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -ESD-Logo_13.2x12mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -ESD-Logo_22x20mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -ESD-Logo_33x30mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -ESD-Logo_44.1x40mm_SilkScreen -Electrostatic discharge Logo -Logo ESD -0 -0 -0 -Symbol -FCC-Logo_7.3x6mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -FCC-Logo_9.6x8mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -FCC-Logo_14.6x12mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -FCC-Logo_24.2x20mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -FCC-Logo_36.3x30mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -FCC-Logo_48.3x40mm_SilkScreen -FCC marking -Logo FCC certification -0 -0 -0 -Symbol -KiCad-Logo2_5mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_5mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_6mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_6mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_8mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_8mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_12mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_12mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_20mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_20mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_30mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_30mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_40mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo2_40mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_5mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_5mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_6mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_6mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_8mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_8mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_12mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_12mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_20mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_20mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_30mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_30mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_40mm_Copper -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -KiCad-Logo_40mm_SilkScreen -KiCad Logo -Logo KiCad -0 -0 -0 -Symbol -OSHW-Logo2_7.3x6mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_7.3x6mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_9.8x8mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_9.8x8mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_14.6x12mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_14.6x12mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_24.3x20mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_24.3x20mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_36.5x30mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_36.5x30mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_48.7x40mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo2_48.7x40mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Logo_5.7x6mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_5.7x6mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_7.5x8mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_7.5x8mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_11.4x12mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_11.4x12mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_19x20mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_19x20mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_28.5x30mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_28.5x30mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_38.1x40mm_Copper -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Logo_38.1x40mm_SilkScreen -Open Source Hardware Logo -Logo OSHW -0 -0 -0 -Symbol -OSHW-Symbol_6.7x6mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_6.7x6mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_8.9x8mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_8.9x8mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_13.4x12mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_13.4x12mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_22.3x20mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_22.3x20mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_33.5x30mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_33.5x30mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_44.5x40mm_Copper -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -OSHW-Symbol_44.5x40mm_SilkScreen -Open Source Hardware Symbol -Logo Symbol OSHW -0 -0 -0 -Symbol -Polarity_Center_Negative_6mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Negative_8mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Negative_12mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Negative_20mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Negative_30mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Negative_40mm_SilkScreen -Polarity Logo, Center Negative -Logo Polarity Center Negative -0 -0 -0 -Symbol -Polarity_Center_Positive_6mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -Polarity_Center_Positive_8mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -Polarity_Center_Positive_12mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -Polarity_Center_Positive_20mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -Polarity_Center_Positive_30mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -Polarity_Center_Positive_40mm_SilkScreen -Polarity Logo, Center Positive -Logo Polarity Center Positive -0 -0 -0 -Symbol -RoHS-Logo_6mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -RoHS-Logo_8mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -RoHS-Logo_12mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -RoHS-Logo_20mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -RoHS-Logo_30mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -RoHS-Logo_40mm_SilkScreen -Restriction of Hazardous Substances Directive Logo -Logo RoHS -0 -0 -0 -Symbol -Symbol_Attention_CopperTop_Big -Symbol, Attention, Copper Top, Big, -Symbol, Attention, Copper Top, Big, -0 -0 -0 -Symbol -Symbol_Attention_CopperTop_Small -Symbol, Attention, Copper Top, Small, -Symbol, Attention, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_Barrel_Polarity -Barrel connector polarity indicator -barrel polarity -0 -0 -0 -Symbol -Symbol_CC-Attribution_CopperTop_Big -Symbol, CC-Attribution, Copper Top, Big, -Symbol, CC-Attribution, Copper Top, Big, -0 -0 -0 -Symbol -Symbol_CC-Attribution_CopperTop_Small -Symbol, CC-Share Alike, Copper Top, Small, -Symbol, CC-Share Alike, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_CC-Noncommercial_CopperTop_Big -Symbol, CC-Noncommercial, Copper Top, Big, -Symbol, CC-Noncommercial, Copper Top, Big, -0 -0 -0 -Symbol -Symbol_CC-Noncommercial_CopperTop_Small -Symbol, CC-Noncommercial Alike, Copper Top, Small, -Symbol, CC-Noncommercial Alike, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_CC-PublicDomain_CopperTop_Big -Symbol, CC-PublicDomain, Copper Top, Big, -Symbol, CC-PublicDomain, Copper Top, Big, -0 -0 -0 -Symbol -Symbol_CC-PublicDomain_CopperTop_Small -Symbol, CC-Public Domain, Copper Top, Small, -Symbol, CC-Public Domain, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_CC-PublicDomain_SilkScreenTop_Big -Symbol, CC-PublicDomain, SilkScreen Top, Big, -Symbol, CC-PublicDomain, SilkScreen Top, Big, -0 -0 -0 -Symbol -Symbol_CC-ShareAlike_CopperTop_Big -Symbol, CC-Share Alike, Copper Top, Big, -Symbol, CC-Share Alike, Copper Top, Big, -0 -0 -0 -Symbol -Symbol_CC-ShareAlike_CopperTop_Small -Symbol, CC-Share Alike, Copper Top, Small, -Symbol, CC-Share Alike, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_CreativeCommonsPublicDomain_CopperTop_Small -Symbol, Creative Commons Public Domain, CopperTop, Small, -Symbol, Creative Commons Public Domain, CopperTop, Small, -0 -0 -0 -Symbol -Symbol_CreativeCommonsPublicDomain_SilkScreenTop_Small -Symbol, Creative Commons Public Domain, SilkScreenTop, Small, -Symbol, Creative Commons Public Domain, SilkScreen Top, Small, -0 -0 -0 -Symbol -Symbol_CreativeCommons_CopperTop_Type1_Big -Symbol, Creative Commons, CopperTop, Type 1, Big, -Symbol, Creative Commons, CopperTop, Type 1, Big, -0 -0 -0 -Symbol -Symbol_CreativeCommons_CopperTop_Type2_Big -Symbol, Creative Commons, CopperTop, Type 2, Big, -Symbol, Creative Commons, CopperTop, Type 2, Big, -0 -0 -0 -Symbol -Symbol_CreativeCommons_CopperTop_Type2_Small -Symbol, Creative Commons, CopperTop, Type 2, Small, -Symbol, Creative Commons, CopperTop, Type 2, Small, -0 -0 -0 -Symbol -Symbol_CreativeCommons_SilkScreenTop_Type2_Big -Symbol, Creative Commons, SilkScreen Top, Type 2, Big, -Symbol, Creative Commons, SilkScreen Top, Type 2, Big, -0 -0 -0 -Symbol -Symbol_Danger_CopperTop_Big -Symbol, Danger, CopperTop, Big, -Symbol, Danger, CopperTop, Big, -0 -0 -0 -Symbol -Symbol_Danger_CopperTop_Small -Symbol, Danger, Copper Top, Small, -Symbol, Danger, Copper Top, Small, -0 -0 -0 -Symbol -Symbol_ESD-Logo-Text_CopperTop - +Audio_Module +Reverb_BTDR-1H +Digital Reverberation Unit, http://www.belton.co.kr/inc/downfile.php?seq=17&file=pdf (footprint from http://www.uk-electronic.de/PDF/BTDR-1.pdf) +audio belton reverb +0 +7 +7 +Audio_Module +Reverb_BTDR-1V +Digital Reverberation Unit, http://www.belton.co.kr/inc/downfile.php?seq=17&file=pdf (footprint from http://www.uk-electronic.de/PDF/BTDR-1.pdf) +audio belton reverb +0 +7 +7 +Battery +BatteryHolder_Bulgin_BX0036_1xC +Bulgin Battery Holder, BX0036, Battery Type C (https://www.bulgin.com/products/pub/media/bulgin/data/Battery_holders.pdf) +Bulgin BX0036 +0 +2 +2 +Battery +BatteryHolder_ComfortableElectronic_CH273-2450_1x2450 +Comfortable Electronic CR2450 battery holder, http://www.comf.com.tw/ProductDetail.asp?no=148 +Comfortable Electronic CR2450 +0 +2 +2 +Battery +BatteryHolder_Eagle_12BH611-GR +https://eu.mouser.com/datasheet/2/209/EPD-200766-1274481.pdf +9V Battery Holder +0 +2 +2 +Battery +BatteryHolder_Keystone_103_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=719 +Keystone type 103 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_104_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=744 +Keystone type 104 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_105_1x2430 +http://www.keyelco.com/product-pdf.cfm?p=745 +Keystone type 105 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_106_1x20mm +http://www.keyelco.com/product-pdf.cfm?p=720 +Keystone type 106 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_107_1x23mm +http://www.keyelco.com/product-pdf.cfm?p=746 +Keystone type 107 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_500 +Keystone #500, CR1220 battery holder, http://www.keyelco.com/product-pdf.cfm?p=710 +CR1220 battery holder +0 +2 +2 +Battery +BatteryHolder_Keystone_1042_1x18650 +Battery holder for 18650 cylindrical cells http://www.keyelco.com/product.cfm/product_id/918 +18650 Keystone 1042 Li-ion +0 +2 +2 +Battery +BatteryHolder_Keystone_1058_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=14028 +Keystone type 1058 coin cell retainer +0 +2 +2 +Battery +BatteryHolder_Keystone_1060_1x2032 +http://www.keyelco.com/product-pdf.cfm?p=726 +CR2032 BR2032 BatteryHolder Battery +0 +2 +2 +Battery +BatteryHolder_Keystone_2460_1xAA +https://www.keyelco.com/product-pdf.cfm?p=1025 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2462_2xAA +2xAA cell battery holder, Keystone P/N 2462, https://www.keyelco.com/product-pdf.cfm?p=1027 +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2466_1xAAA +1xAAA Battery Holder, Keystone, Plastic Case, http://www.keyelco.com/product-pdf.cfm?p=1031 +AAA battery holder Keystone +0 +2 +2 +Battery +BatteryHolder_Keystone_2468_2xAAA +2xAAA cell battery holder, Keystone P/N 2468, http://www.keyelco.com/product-pdf.cfm?p=1033 +AAA battery cell holder +0 +2 +2 +Battery +BatteryHolder_Keystone_2479_3xAAA +Keystone Battery Holder, 2479, Battery Type 3xAAA (Script generated with StandardBox.py) (Keystone Battery Holder, 2479, Battery Type 3xAAA) +Keystone Battery Holder 2479 Battery Type 3xAAA +0 +2 +2 +Battery +BatteryHolder_Keystone_2993 +http://www.keyelco.com/product-pdf.cfm?p=776 +Keystone type 2993 negative battery contact +0 +1 +1 +Battery +BatteryHolder_Keystone_2998_1x6.8mm +www.keyelco.com/product-pdf.cfm?p=763 +Keystone type 2998 battery holder +0 +3 +2 +Battery +BatteryHolder_Keystone_3000_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=777 +Keystone type 3000 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3001_1x12mm +http://www.keyelco.com/product-pdf.cfm?p=778 +Keystone type 3001 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3002_1x2032 +https://www.tme.eu/it/Document/a823211ec201a9e209042d155fe22d2b/KEYS2996.pdf +BR2016 CR2016 DL2016 BR2020 CL2020 BR2025 CR2025 DL2025 DR2032 CR2032 DL2032 +0 +3 +2 +Battery +BatteryHolder_Keystone_3008_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=786 +Keystone type 3008 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3009_1x2450 +http://www.keyelco.com/product-pdf.cfm?p=787 +Keystone type 3009 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_Keystone_3034_1x20mm +Keystone 3034 SMD battery holder for 2020, 2025 and 2032 coincell batteries. http://www.keyelco.com/product-pdf.cfm?p=798 +Keystone type 3034 coin cell retainer +0 +3 +2 +Battery +BatteryHolder_LINX_BAT-HLD-012-SMT +SMT battery holder for CR1216/1220/1225, https://linxtechnologies.com/wp/wp-content/uploads/bat-hld-012-smt.pdf +battery holder coin cell cr1216 cr1220 cr1225 +0 +3 +2 +Battery +BatteryHolder_MPD_BA9VPC_1xPP3 +1xPP3 (9V) battery holder, Memory Protection Devices P/N BA9VPC, http://www.memoryprotectiondevices.com/datasheets/BA9VPC-datasheet.pdf +PP3 Battery Holder BA9VPC 9V +0 +2 +2 +Battery +BatteryHolder_MPD_BC2AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC2AAPC, http://www.memoryprotectiondevices.com/datasheets/BC2AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC12AAPC_2xAA +2xAA cell battery holder, Memory Protection Devices P/N BC12AAPC, http://www.memoryprotectiondevices.com/datasheets/BC12AAPC-datasheet.pdf +AA battery cell holder +0 +2 +2 +Battery +BatteryHolder_MPD_BC2003_1x2032 +http://www.memoryprotectiondevices.com/datasheets/BC-2003-datasheet.pdf +BC2003 CR2032 2032 Battery Holder +0 +3 +2 +Battery +BatteryHolder_MPD_BH-18650-PC2 +18650 Battery Holder (http://www.memoryprotectiondevices.com/datasheets/BK-18650-PC2-datasheet.pdf) +18650 Battery Holder +0 +2 +2 +Battery +BatteryHolder_Seiko_MS621F +Seiko MS621F, https://www.sii.co.jp/en/me/files/2014/02/file_EXTENDED_PRDCT_SPEC_75_FILE_11.jpg +Seiko MS621F +0 +2 +2 +Battery +BatteryHolder_TruPower_BH-331P_3xAA +Keystone Battery Holder BH-331P Battery Type 3xAA (Script generated with StandardBox.py) (Keystone Battery Holder BH-331P Battery Type 3xAA) +Battery Holder BH-331P Battery Type 3xAA +0 +2 +2 +Battery +Battery_CR1225 +CR1225 battery +battery CR1225 coin cell +0 +0 +0 +Battery +Battery_Panasonic_CR1025-VSK_Vertical_CircularHoles +Panasonic CR-1025/VSK battery +battery CR-1025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1220-VCN_Vertical_CircularHoles +Panasonic CR-1220/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D140.PDF +battery CR-1220 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR1632-V1AN_Vertical_CircularHoles +Panasonic CR-1632-V1AN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D464.PDF +battery CR-1632 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2025-V1AK_Vertical_CircularHoles +Panasonic CR-2025/V1AK battery, +battery CR-2025 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2032-VS1N_Vertical_CircularHoles +Panasonic CR-2032/VS1N battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D348.PDF +battery CR-2032 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2354-VCN_Vertical_CircularHoles +Panasonic CR-2354/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D486.PDF +battery CR-2354/VCN coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR2450-VAN_Vertical_CircularHoles +Panasonic CR-2450/VAN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D492.PDF +battery CR-2450 coin cell +0 +2 +2 +Battery +Battery_Panasonic_CR2477-VCN_Vertical_CircularHoles +Panasonic CR-2477/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D502.PDF +battery CR-2477 coin cell vertical +0 +2 +2 +Battery +Battery_Panasonic_CR3032-VCN_Vertical_CircularHoles +Panasonic CR-3032/VCN battery, https://industrial.panasonic.com/cdbs/www-data/pdf2/AAA4000/AAA4000D508.PDF +battery CR-3032 coin cell vertical +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_PCB +Cherry MX keyswitch, 1.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.00u_Plate +Cherry MX keyswitch, 1.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_PCB +Cherry MX keyswitch, 1.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.25u_Plate +Cherry MX keyswitch, 1.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_PCB +Cherry MX keyswitch, 1.50u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.50u_Plate +Cherry MX keyswitch, 1.50u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.50u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_PCB +Cherry MX keyswitch, 1.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_1.75u_Plate +Cherry MX keyswitch, 1.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 1.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_PCB +Cherry MX keyswitch, 2.00u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Plate +Cherry MX keyswitch, 2.00u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_PCB +Cherry MX keyswitch, 2.00u, vertical, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.00u_Vertical_Plate +Cherry MX keyswitch, 2.00u, vertical, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.00u vertical plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_PCB +Cherry MX keyswitch, 2.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.25u_Plate +Cherry MX keyswitch, 2.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_PCB +Cherry MX keyswitch, 2.75u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_2.75u_Plate +Cherry MX keyswitch, 2.75u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 2.75u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_PCB +Cherry MX keyswitch, 6.25u, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_6.25u_Plate +Cherry MX keyswitch, 6.25u, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch 6.25u plate +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_PCB +Cherry MX keyswitch, ISO Enter, PCB mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter PCB +0 +2 +2 +Button_Switch_Keyboard +SW_Cherry_MX_ISOEnter_Plate +Cherry MX keyswitch, ISO Enter, plate mount, http://cherryamericas.com/wp-content/uploads/2014/12/mx_cat.pdf +Cherry MX keyswitch ISO enter plate +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.00u +Matias/ALPS keyswitch, 1.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.25u +Matias/ALPS keyswitch, 1.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.50u +Matias/ALPS keyswitch, 1.50u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.50u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_1.75u +Matias/ALPS keyswitch, 1.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 1.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.00u +Matias/ALPS keyswitch, 2.00u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.00u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.25u +Matias/ALPS keyswitch, 2.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_2.75u +Matias/ALPS keyswitch, 2.75u, http://matias.ca/switches/ +Matias ALPS keyswitch 2.75u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_6.25u +Matias/ALPS keyswitch, 6.25u, http://matias.ca/switches/ +Matias ALPS keyswitch 6.25u +0 +2 +2 +Button_Switch_Keyboard +SW_Matias_ISOEnter +Matias/ALPS keyswitch, ISO Enter, http://matias.ca/switches/ +Matias ALPS keyswitch ISO enter +0 +2 +2 +Button_Switch_SMD +Nidec_Copal_SH-7010A +4-bit rotary coded switch, J-hook, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7010B +4-bit rotary coded switch, gull wing, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_SMD +Nidec_Copal_SH-7040B +4-bit rotary coded switch, gull wing, Gray code, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +5 +5 +Button_Switch_SMD +Panasonic_EVQPUJ_EVQPUA +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUJ EVQPUA +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUK_EVQPUB +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUK EVQPUB +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUL_EVQPUC +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUL EVQPUC +0 +4 +2 +Button_Switch_SMD +Panasonic_EVQPUM_EVQPUD +http://industrial.panasonic.com/cdbs/www-data/pdf/ATV0000/ATV0000CE5.pdf +SMD SMT SPST EVQPUM EVQPUD +0 +4 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 1x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W8.61mm_P2.54mm_LowProfile +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W8.61mm_P2.54mm +SMD 1x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01A_W5.08mm_P1.27mm_JPin +SMD 1x-dip-switch SPST Copal_CHS-01A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CHS-01B_W7.62mm_P1.27mm +SMD 1x-dip-switch SPST Copal_CHS-01B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Copal_CVS-01xB_W5.9mm_P1mm +SMD 1x-dip-switch SPST Copal_CVS-01xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +6 +3 +Button_Switch_SMD +SW_DIP_SPSTx01_Slide_Omron_A6S-110x_W8.9mm_P2.54mm +SMD 1x-dip-switch SPST Omron_A6S-110x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +2 +2 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 2x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W8.61mm_P2.54mm_LowProfile +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W8.61mm_P2.54mm +SMD 2x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02A_W5.08mm_P1.27mm_JPin +SMD 2x-dip-switch SPST Copal_CHS-02A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CHS-02B_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST Copal_CHS-02B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Copal_CVS-02xB_W5.9mm_P1mm +SMD 2x-dip-switch SPST Copal_CVS-02xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +8 +5 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TJ_W5.25mm_P1.27mm_JPin +SMD 2x-dip-switch SPST KingTek_DSHP02TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_KingTek_DSHP02TS_W7.62mm_P1.27mm +SMD 2x-dip-switch SPST KingTek_DSHP02TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6H-2101_W6.15mm_P1.27mm +SMD 2x-dip-switch SPST Omron_A6H-2101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx02_Slide_Omron_A6S-210x_W8.9mm_P2.54mm +SMD 2x-dip-switch SPST Omron_A6S-210x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +4 +4 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 3x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W8.61mm_P2.54mm_LowProfile +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W8.61mm_P2.54mm +SMD 3x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Copal_CVS-03xB_W5.9mm_P1mm +SMD 3x-dip-switch SPST Copal_CVS-03xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +10 +7 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TJ_W5.25mm_P1.27mm_JPin +SMD 3x-dip-switch SPST KingTek_DSHP03TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_KingTek_DSHP03TS_W7.62mm_P1.27mm +SMD 3x-dip-switch SPST KingTek_DSHP03TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx03_Slide_Omron_A6S-310x_W8.9mm_P2.54mm +SMD 3x-dip-switch SPST Omron_A6S-310x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +6 +6 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 4x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W8.61mm_P2.54mm_LowProfile +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W8.61mm_P2.54mm +SMD 4x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04A_W5.08mm_P1.27mm_JPin +SMD 4x-dip-switch SPST Copal_CHS-04A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CHS-04B_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST Copal_CHS-04B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Copal_CVS-04xB_W5.9mm_P1mm +SMD 4x-dip-switch SPST Copal_CVS-04xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +12 +9 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TJ_W5.25mm_P1.27mm_JPin +SMD 4x-dip-switch SPST KingTek_DSHP04TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_KingTek_DSHP04TS_W7.62mm_P1.27mm +SMD 4x-dip-switch SPST KingTek_DSHP04TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6H-4101_W6.15mm_P1.27mm +SMD 4x-dip-switch SPST Omron_A6H-4101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx04_Slide_Omron_A6S-410x_W8.9mm_P2.54mm +SMD 4x-dip-switch SPST Omron_A6S-410x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +8 +8 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 5x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W8.61mm_P2.54mm_LowProfile +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W8.61mm_P2.54mm +SMD 5x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TJ_W5.25mm_P1.27mm_JPin +SMD 5x-dip-switch SPST KingTek_DSHP05TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_KingTek_DSHP05TS_W7.62mm_P1.27mm +SMD 5x-dip-switch SPST KingTek_DSHP05TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx05_Slide_Omron_A6S-510x_W8.9mm_P2.54mm +SMD 5x-dip-switch SPST Omron_A6S-510x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +10 +10 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 6x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W8.61mm_P2.54mm_LowProfile +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W8.61mm_P2.54mm +SMD 6x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06A_W5.08mm_P1.27mm_JPin +SMD 6x-dip-switch SPST Copal_CHS-06A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Copal_CHS-06B_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST Copal_CHS-06B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TJ_W5.25mm_P1.27mm_JPin +SMD 6x-dip-switch SPST KingTek_DSHP06TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_KingTek_DSHP06TS_W7.62mm_P1.27mm +SMD 6x-dip-switch SPST KingTek_DSHP06TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6H-6101_W6.15mm_P1.27mm +SMD 6x-dip-switch SPST Omron_A6H-6101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx06_Slide_Omron_A6S-610x_W8.9mm_P2.54mm +SMD 6x-dip-switch SPST Omron_A6S-610x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +12 +12 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 7x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W8.61mm_P2.54mm_LowProfile +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W8.61mm_P2.54mm +SMD 7x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TJ_W5.25mm_P1.27mm_JPin +SMD 7x-dip-switch SPST KingTek_DSHP07TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_KingTek_DSHP07TS_W7.62mm_P1.27mm +SMD 7x-dip-switch SPST KingTek_DSHP07TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx07_Slide_Omron_A6S-710x_W8.9mm_P2.54mm +SMD 7x-dip-switch SPST Omron_A6S-710x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +14 +14 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 8x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W8.61mm_P2.54mm_LowProfile +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W8.61mm_P2.54mm +SMD 8x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08A_W5.08mm_P1.27mm_JPin +SMD 8x-dip-switch SPST Copal_CHS-08A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CHS-08B_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST Copal_CHS-08B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Copal_CVS-08xB_W5.9mm_P1mm +SMD 8x-dip-switch SPST Copal_CVS-08xB, Slide, row spacing 5.9 mm (232 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/cvs.pdf) +SMD DIP Switch SPST Slide 5.9mm 232mil +0 +20 +17 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TJ_W5.25mm_P1.27mm_JPin +SMD 8x-dip-switch SPST KingTek_DSHP08TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_KingTek_DSHP08TS_W7.62mm_P1.27mm +SMD 8x-dip-switch SPST KingTek_DSHP08TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6H-8101_W6.15mm_P1.27mm +SMD 8x-dip-switch SPST Omron_A6H-8101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx08_Slide_Omron_A6S-810x_W8.9mm_P2.54mm +SMD 8x-dip-switch SPST Omron_A6S-810x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +16 +16 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 9x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W8.61mm_P2.54mm_LowProfile +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W8.61mm_P2.54mm +SMD 9x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TJ_W5.25mm_P1.27mm_JPin +SMD 9x-dip-switch SPST KingTek_DSHP09TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_KingTek_DSHP09TS_W7.62mm_P1.27mm +SMD 9x-dip-switch SPST KingTek_DSHP09TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx09_Slide_Omron_A6S-910x_W8.9mm_P2.54mm +SMD 9x-dip-switch SPST Omron_A6S-910x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +18 +18 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 10x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W8.61mm_P2.54mm_LowProfile +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W8.61mm_P2.54mm +SMD 10x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10A_W5.08mm_P1.27mm_JPin +SMD 10x-dip-switch SPST Copal_CHS-10A, Slide, row spacing 5.08 mm (200 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD, JPin +SMD DIP Switch SPST Slide 5.08mm 200mil SMD JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Copal_CHS-10B_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST Copal_CHS-10B, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.nidec-copal-electronics.com/e/catalog/switch/chs.pdf), SMD +SMD DIP Switch SPST Slide 7.62mm 300mil SMD +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TJ_W5.25mm_P1.27mm_JPin +SMD 10x-dip-switch SPST KingTek_DSHP10TJ, Slide, row spacing 5.25 mm (206 mils), body size (see http://www.kingtek.net.cn/pic/201601201446313350.pdf), JPin +SMD DIP Switch SPST Slide 5.25mm 206mil JPin +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_KingTek_DSHP10TS_W7.62mm_P1.27mm +SMD 10x-dip-switch SPST KingTek_DSHP10TS, Slide, row spacing 7.62 mm (300 mils), body size (see http://www.kingtek.net.cn/pic/201601201417455112.pdf) +SMD DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6H-10101_W6.15mm_P1.27mm +SMD 10x-dip-switch SPST Omron_A6H-10101, Slide, row spacing 6.15 mm (242 mils), body size (see https://www.omron.com/ecb/products/pdf/en-a6h.pdf) +SMD DIP Switch SPST Slide 6.15mm 242mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx10_Slide_Omron_A6S-1010x_W8.9mm_P2.54mm +SMD 10x-dip-switch SPST Omron_A6S-1010x, Slide, row spacing 8.9 mm (350 mils), body size (see http://omronfs.omron.com/en_US/ecb/products/pdf/en-a6s.pdf) +SMD DIP Switch SPST Slide 8.9mm 350mil +0 +20 +20 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 11x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W8.61mm_P2.54mm_LowProfile +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W8.61mm_P2.54mm +SMD 11x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +22 +22 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W6.73mm_P2.54mm_LowProfile_JPin +SMD 12x-dip-switch SPST , Slide, row spacing 6.73 mm (264 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile, JPin +SMD DIP Switch SPST Slide 6.73mm 264mil SMD LowProfile JPin +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W8.61mm_P2.54mm_LowProfile +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/219.pdf), SMD, LowProfile +SMD DIP Switch SPST Slide 8.61mm 338mil SMD LowProfile +0 +24 +24 +Button_Switch_SMD +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W8.61mm_P2.54mm +SMD 12x-dip-switch SPST , Slide, row spacing 8.61 mm (338 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/204.pdf), SMD +SMD DIP Switch SPST Slide 8.61mm 338mil SMD +0 +24 +24 +Button_Switch_SMD +SW_DPDT_CK_JS202011JCQN +Sub-miniature slide switch, vertical, SMT J bend https://dznh3ojzb2azq.cloudfront.net/products/Slide/JS/documents/datasheet.pdf +switch DPDT SMT +0 +6 +6 +Button_Switch_SMD +SW_MEC_5GSH9 +MEC 5G single pole normally-open tactile switch +switch normally-open pushbutton push-button +0 +4 +4 +Button_Switch_SMD +SW_Push_1P1T-MP_NO_Horizontal_Alps_SKRTLAE010 +Side push button (https://www.alps.com/prod/info/E/PDF/Tact/SurfaceMount/SKRT/SKRT.pdf) +push horizontal SPST 1P1T +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T-SH_NO_CK_KMR2xxG +CK components KMR2 tactile switch with ground pin http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +5 +3 +Button_Switch_SMD +SW_Push_1P1T_NO_6x6mm_H9.5mm +tactile push button, 6x6mm e.g. PTS645xx series, height=9.5mm +tact sw push 6mm smd +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KMR2 +CK components KMR2 tactile switch http://www.ckswitches.com/media/1479/kmr2.pdf +tactile switch kmr2 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC6xxJ +CK components KSC6 tactile switch https://www.ckswitches.com/media/1972/ksc6.pdf +tactile switch ksc6 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_KSC7xxJ +CK components KSC7 tactile switch https://www.ckswitches.com/media/1973/ksc7.pdf +tactile switch ksc7 +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_CK_PTS125Sx43PSMTR +C&K Switches 1P1T SMD PTS125 Series 12mm Tact Switch with Pegs, https://www.ckswitches.com/media/1462/pts125.pdf +Button Tactile Switch SPST 1P1T +0 +4 +2 +Button_Switch_SMD +SW_Push_1P1T_NO_Vertical_Wuerth_434133025816 +https://katalog.we-online.com/em/datasheet/434133025816.pdf +tactile switch Wurth Wuerth +0 +4 +2 +Button_Switch_SMD +SW_Push_SPST_NO_Alps_SKRK +http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKRK/SKRKAHE020.html +SMD SMT button +0 +2 +2 +Button_Switch_SMD +SW_SP3T_PCM13 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf 0 +8 +4 +Button_Switch_SMD +SW_SPDT_CK-JS102011SAQN +Sub-miniature slide switch, right-angle, http://www.ckswitches.com/media/1422/js.pdf +switch spdt 0 +3 +3 +Button_Switch_SMD +SW_SPDT_PCM12 +Ultraminiature Surface Mount Slide Switch, right-angle, https://www.ckswitches.com/media/1424/pcm.pdf + 0 -Symbol -Symbol_ESD-Logo_CopperTop -ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, -ESD-Logo, similar JEDEC-14, without text, ohne Text, Copper Top, +7 +3 +Button_Switch_SMD +SW_SPST_B3S-1000 +Surface Mount Tactile Switch for High-Density Packaging +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3S-1100 +Surface Mount Tactile Switch for High-Density Packaging with Ground Terminal +Tactile Switch +0 +5 +3 +Button_Switch_SMD +SW_SPST_B3SL-1002P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3SL-1022P +Middle Stroke Tactile Switch, B3SL +Middle Stroke Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-1100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-1100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Top-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3000P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, without Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3000P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, without Ground Terminal, with Boss +Tactile Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_B3U-3100P +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, without Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_B3U-3100P-B +Ultra-small-sized Tactile Switch with High Contact Reliability, Side-actuated Model, with Ground Terminal, with Boss +Tactile Switch +0 +3 +3 +Button_Switch_SMD +SW_SPST_CK_KXT3 +https://www.ckswitches.com/media/1465/kxt3.pdf +Switch SPST KXT3 +0 +2 +2 +Button_Switch_SMD +SW_SPST_CK_RS282G05A3 +https://www.mouser.com/ds/2/60/RS-282G05A-SM_RT-1159762.pdf +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVPBF +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP0 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP2 +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7A +Light Touch Switch,https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE20.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQP7C +Light Touch Switch + +0 +4 +2 +Button_Switch_SMD +SW_SPST_EVQPE1 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE7.pdf + +0 +2 +2 +Button_Switch_SMD +SW_SPST_EVQQ2 +Light Touch Switch, https://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE28.pdf + +0 +4 +2 +Button_Switch_SMD +SW_SPST_FSMSM +http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1437566-3&DocType=Customer+Drawing&DocLang=English +SPST button tactile switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_Omron_B3FS-100xP +Surface Mount Tactile Switch for High-Density Mounting, 3.1mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_Omron_B3FS-101xP +Surface Mount Tactile Switch for High-Density Mounting, 4.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_Omron_B3FS-105xP +Surface Mount Tactile Switch for High-Density Mounting, 7.3mm height, https://omronfs.omron.com/en_US/ecb/products/pdf/en-b3fs.pdf +Tactile Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_PTS645 +C&K Components SPST SMD PTS645 Series 6mm Tact Switch +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_PTS810 +C&K Components, PTS 810 Series, Microminiature SMT Top Actuated, http://www.ckswitches.com/media/1476/pts810.pdf +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A08 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_Panasonic_EVQPL_3PL_5PL_PT_A15 +Light Touch Switch, http://industrial.panasonic.com/cdbs/www-data/pdf/ATK0000/ATK0000CE3.pdf +SMD SMT SPST EVQPL EVQPT +0 +6 +3 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-G1 +Coto Technologies SPST Reed Switch CT05-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT05-XXXX-J1 +Coto Technologies SPST Reed Switch CT05-XXXX-J1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G1 +Coto Technologies SPST Reed Switch CT10-XXXX-G1 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G2 +Coto Technologies SPST Reed Switch CT10-XXXX-G2 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_REED_CT10-XXXX-G4 +Coto Technologies SPST Reed Switch CT10-XXXX-G4 +Coto Reed SPST Switch +0 +2 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, With stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAFE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_SKQG_WithoutStem +ALPS 5.2mm Square Low-profile Type (Surface Mount) SKQG Series, Without stem, http://www.alps.com/prod/info/E/HTML/Tact/SurfaceMount/SKQG/SKQGAEE010.html +SPST Button Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305A +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305B +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3305C +https://www.e-switch.com/system/asset/product_line/data_sheet/213/TL3305.pdf +TL3305 Series Tact Switch +0 +4 +2 +Button_Switch_SMD +SW_SPST_TL3342 +Low-profile SMD Tactile Switch, https://www.e-switch.com/system/asset/product_line/data_sheet/165/TL3342.pdf +SPST Tactile Switch +0 +4 +2 +Button_Switch_THT +KSA_Tactile_SPST +KSA http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SWITCH SMD KSA SW +0 +5 +5 +Button_Switch_THT +Nidec_Copal_SH-7010C +4-bit rotary coded switch, through-hole, https://www.nidec-copal-electronics.com/e/catalog/switch/sh-7000.pdf +rotary switch bcd +0 +6 +5 +Button_Switch_THT +Push_E-Switch_KS01Q01 +E-Switch KS01Q01 http://spec_sheets.e-switch.com/specs/29-KS01Q01.pdf +Push Button +0 +4 +4 +Button_Switch_THT +SW_CW_GPTS203211B +SPST Off-On Pushbutton, 1A, 30V, CW Industries P/N GPTS203211B, http://switches-connectors-custom.cwind.com/Asset/GPTS203211BR2.pdf +SPST button switch Off-On +0 +2 +2 +Button_Switch_THT +SW_CuK_JS202011AQN_DPDT_Angled +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_JS202011CQN_DPDT_Straight +CuK sub miniature slide switch, JS series, DPDT, right angle, http://www.ckswitches.com/media/1422/js.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_CuK_OS102011MA1QN1_SPDT_Angled +CuK miniature slide switch, OS series, SPDT, right angle, http://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_DIP_SPSTx01_Piano_10.8x4.1mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x4.1mm +DIP Switch SPST Piano 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_6.7x4.1mm_W7.62mm_P2.54mm_LowProfile +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x4.1mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx01_Slide_9.78x4.72mm_W7.62mm_P2.54mm +1x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x4.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +2 +2 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_10.8x6.64mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x6.64mm +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Piano_CTS_Series194-2MSTN_W7.62mm_P2.54mm +2x-dip-switch SPST CTS_Series194-2MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_6.7x6.64mm_W7.62mm_P2.54mm_LowProfile +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x6.64mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx02_Slide_9.78x7.26mm_W7.62mm_P2.54mm +2x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x7.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +4 +4 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_10.8x9.18mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x9.18mm +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Piano_CTS_Series194-3MSTN_W7.62mm_P2.54mm +3x-dip-switch SPST CTS_Series194-3MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_6.7x9.18mm_W7.62mm_P2.54mm_LowProfile +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x9.18mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx03_Slide_9.78x9.8mm_W7.62mm_P2.54mm +3x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x9.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +6 +6 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_10.8x11.72mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x11.72mm +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Piano_CTS_Series194-4MSTN_W7.62mm_P2.54mm +4x-dip-switch SPST CTS_Series194-4MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_6.7x11.72mm_W7.62mm_P2.54mm_LowProfile +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x11.72mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx04_Slide_9.78x12.34mm_W7.62mm_P2.54mm +4x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x12.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +8 +8 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_10.8x14.26mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x14.26mm +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Piano_CTS_Series194-5MSTN_W7.62mm_P2.54mm +5x-dip-switch SPST CTS_Series194-5MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_6.7x14.26mm_W7.62mm_P2.54mm_LowProfile +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x14.26mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx05_Slide_9.78x14.88mm_W7.62mm_P2.54mm +5x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x14.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +10 +10 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_10.8x16.8mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x16.8mm +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Piano_CTS_Series194-6MSTN_W7.62mm_P2.54mm +6x-dip-switch SPST CTS_Series194-6MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_6.7x16.8mm_W7.62mm_P2.54mm_LowProfile +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x16.8mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx06_Slide_9.78x17.42mm_W7.62mm_P2.54mm +6x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x17.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +12 +12 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_10.8x19.34mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x19.34mm +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Piano_CTS_Series194-7MSTN_W7.62mm_P2.54mm +7x-dip-switch SPST CTS_Series194-7MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_6.7x19.34mm_W7.62mm_P2.54mm_LowProfile +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x19.34mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx07_Slide_9.78x19.96mm_W7.62mm_P2.54mm +7x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x19.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +14 +14 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_10.8x21.88mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x21.88mm +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Piano_CTS_Series194-8MSTN_W7.62mm_P2.54mm +8x-dip-switch SPST CTS_Series194-8MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_6.7x21.88mm_W7.62mm_P2.54mm_LowProfile +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x21.88mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx08_Slide_9.78x22.5mm_W7.62mm_P2.54mm +8x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x22.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +16 +16 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_10.8x24.42mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x24.42mm +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Piano_CTS_Series194-9MSTN_W7.62mm_P2.54mm +9x-dip-switch SPST CTS_Series194-9MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_6.7x24.42mm_W7.62mm_P2.54mm_LowProfile +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x24.42mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx09_Slide_9.78x25.04mm_W7.62mm_P2.54mm +9x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x25.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +18 +18 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_10.8x26.96mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x26.96mm +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Piano_CTS_Series194-10MSTN_W7.62mm_P2.54mm +10x-dip-switch SPST CTS_Series194-10MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_6.7x26.96mm_W7.62mm_P2.54mm_LowProfile +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x26.96mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx10_Slide_9.78x27.58mm_W7.62mm_P2.54mm +10x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x27.58mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +20 +20 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_10.8x29.5mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x29.5mm +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Piano_CTS_Series194-11MSTN_W7.62mm_P2.54mm +11x-dip-switch SPST CTS_Series194-11MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_6.7x29.5mm_W7.62mm_P2.54mm_LowProfile +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x29.5mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx11_Slide_9.78x30.12mm_W7.62mm_P2.54mm +11x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x30.12mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +22 +22 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_10.8x32.04mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Piano, row spacing 7.62 mm (300 mils), body size 10.8x32.04mm +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Piano_CTS_Series194-12MSTN_W7.62mm_P2.54mm +12x-dip-switch SPST CTS_Series194-12MSTN, Piano, row spacing 7.62 mm (300 mils), body size (see https://www.ctscorp.com/wp-content/uploads/194-195.pdf) +DIP Switch SPST Piano 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_6.7x32.04mm_W7.62mm_P2.54mm_LowProfile +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 6.7x32.04mm (see e.g. https://www.ctscorp.com/wp-content/uploads/209-210.pdf), LowProfile +DIP Switch SPST Slide 7.62mm 300mil LowProfile +0 +24 +24 +Button_Switch_THT +SW_DIP_SPSTx12_Slide_9.78x32.66mm_W7.62mm_P2.54mm +12x-dip-switch SPST , Slide, row spacing 7.62 mm (300 mils), body size 9.78x32.66mm (see e.g. https://www.ctscorp.com/wp-content/uploads/206-208.pdf) +DIP Switch SPST Slide 7.62mm 300mil +0 +24 +24 +Button_Switch_THT +SW_E-Switch_EG1224_SPDT_Angled +E-Switch slide switch, EG series, SPDT, right angle, http://spec_sheets.e-switch.com/specs/P040042.pdf +switch SPDT +0 +7 +3 +Button_Switch_THT +SW_E-Switch_EG1271_DPDT +E-Switch sub miniature slide switch, EG series, DPDT, http://spec_sheets.e-switch.com/specs/P040047.pdf +switch DPDT +0 +6 +6 +Button_Switch_THT +SW_E-Switch_EG2219_DPDT_Angled +E-Switch slide switch, EG series, DPDT, right angle, http://spec_sheets.e-switch.com/specs/P040170.pdf +switch DPDT +0 +10 +6 +Button_Switch_THT +SW_Lever_1P2T_NKK_GW12LxH +Switch, single pole double throw, right angle, http://www.nkkswitches.com/pdf/GW.pdf +switch single-pole double-throw spdt ON-ON horizontal +0 +5 +3 +Button_Switch_THT +SW_MEC_5GTH9 +MEC 5G single pole normally-open tactile switch https://cdn.sos.sk/productdata/80/f6/aabf7be6/5gth9358222.pdf +switch normally-open pushbutton push-button +0 +4 +2 +Button_Switch_THT +SW_NKK_BB15AH +https://www.nkkswitches.com/pdf/Bpushbuttons-1.pdf +Pushbutton Right-angle +0 +5 +3 +Button_Switch_THT +SW_NKK_G1xJP +Switch NKK G1xJP http://www.nkkswitches.com/pdf/gwillum.pdf +SWITCH TOGGLE ILLUM SPDT NKK +0 +6 +6 +Button_Switch_THT +SW_NKK_GW12LJP +Switch, single pole double throw, illuminated paddle, http://www.nkkswitches.com/pdf/gwillum.pdf +switch single-pole double-throw spdt ON-ON illuminated LED +0 +6 +6 +Button_Switch_THT +SW_PUSH-12mm +SW PUSH 12mm https://www.e-switch.com/system/asset/product_line/data_sheet/143/TL1100.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH-12mm_Wuerth-430476085716 +SW PUSH 12mm http://katalog.we-online.de/em/datasheet/430476085716.pdf +tact sw push 12mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm +https://www.omron.com/ecb/products/pdf/en-b3f.pdf +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H4.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=4.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H7.3mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=7.3mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H8mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=8mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H9.5mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=9.5mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_6mm_H13mm +tactile push button, 6x6mm e.g. PHAP33xx series, height=13mm +tact sw push 6mm +0 +4 +2 +Button_Switch_THT +SW_PUSH_E-Switch_FS5700DP_DPDT +FS5700 series pushbutton footswitch, DPDT, https://www.e-switch.com/system/asset/product_line/data_sheet/226/FS5700.pdf +switch DPDT footswitch +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_PUSH_LCD_E3_SAxxxx_SocketPins +Switch with LCD screen E3 SAxxxx +switch normally-open pushbutton push-button LCD +0 +6 +6 +Button_Switch_THT +SW_Push_1P1T_NO_LED_E-Switch_TL1250 +illuminated right angle tact switch https://www.e-switch.com/system/asset/product_line/data_sheet/148/TL1250.pdf +led push switch right angle +0 +6 +4 +Button_Switch_THT +SW_Push_1P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle SPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +5 +3 +Button_Switch_THT +SW_Push_2P1T_Toggle_CK_PVA1xxH1xxxxxxV2 +momentary / push-push button, h=17.5mm C&K PVA1 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA1 DPST +0 +4 +4 +Button_Switch_THT +SW_Push_2P1T_Toggle_CK_PVA1xxH2xxxxxxV2 +momentary / push-push button, h=23mm C&K PVA1 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA1 DPST +0 +4 +4 +Button_Switch_THT +SW_Push_2P1T_Toggle_CK_PVA1xxH3xxxxxxV2 +momentary / push-push button, h=20.5mm C&K PVA1 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA1 DPST +0 +4 +4 +Button_Switch_THT +SW_Push_2P1T_Toggle_CK_PVA1xxH4xxxxxxV2 +momentary / push-push button, h=15mm C&K PVA1 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA1 DPST +0 +4 +4 +Button_Switch_THT +SW_Push_2P2T_Toggle_CK_PVA2OAH5xxxxxxV2 +momentary / push-push button, h=13mm C&K PVA2 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA2 DPDT +0 +6 +6 +Button_Switch_THT +SW_Push_2P2T_Toggle_CK_PVA2xxH1xxxxxxV2 +momentary / push-push button, h=17.5mm C&K PVA2 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA2 DPDT +0 +6 +6 +Button_Switch_THT +SW_Push_2P2T_Toggle_CK_PVA2xxH2xxxxxxV2 +momentary / push-push button, h=23mm C&K PVA2 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA2 DPDT +0 +6 +6 +Button_Switch_THT +SW_Push_2P2T_Toggle_CK_PVA2xxH3xxxxxxV2 +momentary / push-push button, h=20.5mm C&K PVA2 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA2 DPDT +0 +6 +6 +Button_Switch_THT +SW_Push_2P2T_Toggle_CK_PVA2xxH4xxxxxxV2 +momentary / push-push button, h=15mm C&K PVA2 https://www.ckswitches.com/media/1343/pva.pdf +tact sw push PVA2 DPDT +0 +6 +6 +Button_Switch_THT +SW_Push_2P2T_Vertical_E-Switch_800UDP8P1A1M6 + right angle DPDT push button https://www.e-switch.com/system/asset/product_line/data_sheet/210/800U.pdf +IP67 ultra-miniture horizontal +0 +8 +6 +Button_Switch_THT +SW_Slide_1P2T_CK_OS102011MS2Q +CuK miniature slide switch, OS series, SPDT, https://www.ckswitches.com/media/1428/os.pdf +switch SPDT +0 +5 +3 +Button_Switch_THT +SW_TH_Tactile_Omron_B3F-10xx +SW_TH_Tactile_Omron_B3F-10xx_https://www.omron.com/ecb/products/pdf/en-b3f.pdf +Omron B3F-10xx +0 +4 +2 +Button_Switch_THT +SW_Tactile_SKHH_Angled +tactile switch 6mm ALPS SKHH right angle http://www.alps.com/prod/info/E/HTML/Tact/SnapIn/SKHH/SKHHLUA010.html +tactile switch 6mm ALPS SKHH right angle +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx31-2LFS +tactile switch SPST right angle, PTS645VL31-2 LFS +tactile switch SPST angled PTS645VL31-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx39-2LFS +tactile switch SPST right angle, PTS645VL39-2 LFS +tactile switch SPST angled PTS645VL39-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx58-2LFS +tactile switch SPST right angle, PTS645VL58-2 LFS +tactile switch SPST angled PTS645VL58-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_SPST_Angled_PTS645Vx83-2LFS +tactile switch SPST right angle, PTS645VL83-2 LFS +tactile switch SPST angled PTS645VL83-2 LFS C&K Button +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSA0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Button_Switch_THT +SW_Tactile_Straight_KSL0Axx1LFTR +SW PUSH SMALL http://www.ckswitches.com/media/1457/ksa_ksl.pdf +SW PUSH SMALL Tactile C&K +0 +4 +2 +Buzzer_Beeper +Buzzer_12x9.5RM7.6 +Generic Buzzer, D12mm height 9.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_15x7.5RM7.6 +Generic Buzzer, D15mm height 7.5mm with RM7.6mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_CUI_CPT-9019S-SMT +https://www.cui.com/product/resource/cpt-9019s-smt.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_D14mm_H7mm_P10mm +Generic Buzzer, D14mm height 7mm with pitch 10mm +buzzer +0 +2 +2 +Buzzer_Beeper +Buzzer_Mallory_AST1109MLTRQ +Mallory low-profile piezo buzzer, https://www.mspindy.com/specifications/AST1109MLTRQ.pdf +buzzer piezo +0 +2 +2 +Buzzer_Beeper +Buzzer_Murata_PKLCS1212E +Murata Buzzer https://www.murata.com/~/media/webrenewal/support/library/catalog/products/sound/p37e.ashx +Murata Buzzer Beeper +0 +2 +2 +Buzzer_Beeper +Buzzer_Murata_PKMCS0909E +Murata Buzzer http://www.murata.com/en-us/api/pdfdownloadapi?cate=&partno=PKMCS0909E4000-R1 +Murata Buzzer Beeper +0 +2 +2 +Buzzer_Beeper +Buzzer_TDK_PS1240P02BT_D12.2mm_H6.5mm +Buzzer, D12.2mm height 6.5mm, https://product.tdk.com/info/en/catalog/datasheets/piezoelectronic_buzzer_ps_en.pdf +buzzer +0 +2 +2 +Buzzer_Beeper +Indicator_PUI_AI-1440-TWT-24V-2-R +14mm Indicator, https://www.puiaudio.com/media/SpecSheet/AI-1440-TWT-24V-2-R.pdf +piezo buzzer self drive oscillator +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_CUI_CMT-8504-100-SMT +magnetic transducer buzzer, 5V, SPL of 100 dB at 10 cm, https://www.cuidevices.com/product/resource/pdf/cmt-8504-100-smt-tr.pdf +CMT 8504 +0 +4 +4 +Buzzer_Beeper +MagneticBuzzer_CUI_CST-931RP-A +CST-931RP-A, http://www.cui.com/product/resource/cst-931rp-a.pdf +CST-931RP-A +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kingstate_KCG0601 +Buzzer, Elektromagnetic Beeper, Summer, +Kingstate KCG0601 +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_Kobitone_254-EMB84Q-RO +MagneticBuzzer Kobitone 254-EMB84Q-RO https://www.mouser.es/datasheet/2/209/KT-400385-1171904.pdf +MagneticBuzzer Kobitone 254-EMB84Q-RO +0 +3 +3 +Buzzer_Beeper +MagneticBuzzer_PUI_AT-0927-TT-6-R +Buzzer Magnetic 9mm AT-0927-TT-6-R, http://www.puiaudio.com/pdf/AT-0927-TT-6-R.pdf +Buzzer Magnetic 9mm AT-0927-TT-6-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-009-RC +Buzzer, Elektromagnetic Beeper, Summer, 6V-DC, +Pro Signal ABI-009-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABI-010-RC +Buzzer, Elektromagnetic Beeper, Summer, 12V-DC, +Pro Signal ABI-010-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProSignal_ABT-410-RC +Buzzer, Elektromagnetic Beeper, Summer, 1,5V-DC, +Pro Signal ABT-410-RC +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_ProjectsUnlimited_AI-4228-TWT-R +Buzzer, Elektromagnetic Beeper, Summer, 3-28V-DC, https://www.kynix.com/uploadfiles/pdf/AI-4228-TWT-R.pdf +Projects Unlimited AI-4228-TWT-R +0 +2 +2 +Buzzer_Beeper +MagneticBuzzer_StarMicronics_HMB-06_HMB-12 +Buzzer, Elektromagnetic Beeper, Summer, +Star Micronics HMB-06 HMB-12 +0 +2 +2 +Buzzer_Beeper +PUIAudio_SMT_0825_S_4_R +SMD 8540, http://www.puiaudio.com/product-detail.aspx?partnumber=SMT-0825-S-4-R +SMD 8540 +0 +4 +4 +Buzzer_Beeper +Speaker_CUI_CMR-1206S-67 +Speaker, 30mW, 300-7000Hz, IP67 face, 12x6x2,25mm, https://www.cuidevices.com/product/resource/cmr-12062s-67.pdf +speaker CUI +0 +2 +2 +Calibration_Scale +Gauge_10mm_Type1_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 1, +Gauge Massstab 10mm CopperTop Type 1 0 0 0 -Symbol -Symbol_GNU-GPL_CopperTop_Big -Symbol, GNU-GPL, Copper Top, Big, -Symbol, GNU-GPL, Copper Top, Big, +Calibration_Scale +Gauge_10mm_Type1_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 1, +Gauge Massstab 10mm SilkScreenTop Type 1 0 0 0 -Symbol -Symbol_GNU-GPL_CopperTop_Small -Symbol, GNU-GPL, Copper Top, Small, -Symbol, GNU-GPL, Copper Top, Small, +Calibration_Scale +Gauge_10mm_Type2_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 2, +Gauge Massstab 10mm CopperTop Type 2 0 0 0 -Symbol -Symbol_GNU-Logo_CopperTop -GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, -GNU-Logo, GNU-Head, GNU-Kopf, Copper Top, +Calibration_Scale +Gauge_10mm_Type2_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 2, +Gauge Massstab 10mm SilkScreenTop Type 2 0 0 0 -Symbol -Symbol_GNU-Logo_SilkscreenTop -GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, -GNU-Logo, GNU-Head, GNU-Kopf, Silkscreen, +Calibration_Scale +Gauge_10mm_Type3_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 3, +Gauge Massstab 10mm CopperTop Type 3 0 0 0 -Symbol -Symbol_HighVoltage_Type1_CopperTop_Big -Symbol, HighVoltage, Type1, Copper Top, Big, -Symbol, HighVoltage, Type1, Copper Top, Big, +Calibration_Scale +Gauge_10mm_Type3_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 3, +Gauge Massstab 10mm SilkScreenTop Type 3 0 0 0 -Symbol -Symbol_HighVoltage_Type2_CopperTop_Big -Symbol, HighVoltage, Type2, Copper Top, Big, -Symbol, HighVoltage, Type2, Copper Top, Big, +Calibration_Scale +Gauge_10mm_Type4_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 4, +Gauge Massstab 10mm CopperTop Type 4 0 0 0 -Symbol -Symbol_HighVoltage_Type2_CopperTop_VerySmall -Symbol, High Voltage, Type 2, Copper Top, Very Small, -Symbol, High Voltage, Type 2, Copper Top, Very Small, +Calibration_Scale +Gauge_10mm_Type4_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 4, +Gauge Massstab 10mm SilkScreenTop Type 4 0 0 0 -Symbol -Symbol_Highvoltage_Type1_CopperTop_Small -Symbol, Highvoltage, Type 1, Copper Top, Small, -Symbol, Highvoltage, Type 1, Copper Top, Small, +Calibration_Scale +Gauge_10mm_Type5_CopperTop +Gauge, Massstab, 10mm, CopperTop, Type 5, +Gauge Massstab 10mm CopperTop Type 5 0 0 0 -Symbol -Symbol_Highvoltage_Type2_CopperTop_Small -Symbol, Highvoltage, Type 2, Copper Top, Small, -Symbol, Highvoltage, Type 2, Copper Top, Small, +Calibration_Scale +Gauge_10mm_Type5_SilkScreenTop +Gauge, Massstab, 10mm, SilkScreenTop, Type 5, +Gauge Massstab 10mm SilkScreenTop Type 5 0 0 0 -Symbol -WEEE-Logo_4.2x6mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_50mm_Type1_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 1, +Gauge Massstab 50mm CopperTop Type 1 0 0 0 -Symbol -WEEE-Logo_5.6x8mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_50mm_Type1_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 1, +Gauge Massstab 50mm SilkScreenTop Type 1 0 0 0 -Symbol -WEEE-Logo_8.4x12mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_50mm_Type2_CopperTop +Gauge, Massstab, 50mm, CopperTop, Type 2, +Gauge Massstab 50mm CopperTop Type 2 0 0 0 -Symbol -WEEE-Logo_14x20mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_50mm_Type2_SilkScreenTop +Gauge, Massstab, 50mm, SilkScreenTop, Type 2, +Gauge Massstab 50mm SilkScreenTop Type 2 0 0 0 -Symbol -WEEE-Logo_21x30mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_100mm_Grid_Type1_CopperTop +Gauge, Massstab, 100mm, Gitter, Grid, CopperTop, Type 1, +Gauge Massstab 100mm Gitter Grid CopperTop Type 1 0 0 0 -Symbol -WEEE-Logo_28.1x40mm_SilkScreen -Waste Electrical and Electronic Equipment Directive -Logo WEEE +Calibration_Scale +Gauge_100mm_Type1_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 1, +Gauge Massstab 100mm CopperTop Type 1 0 0 0 +Calibration_Scale +Gauge_100mm_Type1_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 1, +Gauge Massstab 100mm SilkScreenTop Type 1 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_CopperTop +Gauge, Massstab, 100mm, CopperTop, Type 2, +Gauge Massstab 100mm CopperTop Type 2 +0 +0 +0 +Calibration_Scale +Gauge_100mm_Type2_SilkScreenTop +Gauge, Massstab, 100mm, SilkScreenTop, Type 2, +Gauge Massstab 100mm SilkScreenTop Type 2 +0 +0 +0 +Capacitor_SMD +CP_Elec_3x5.3 +SMT capacitor, aluminium electrolytic, 3x5.3, Cornell Dubilier Electronics +Capacitor Electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_3x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 3.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 4.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.3 +SMD capacitor, aluminum electrolytic, Vishay, 4.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.4 +SMD capacitor, aluminum electrolytic, Panasonic A5 / Nichicon, 4.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 4.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_4x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 4.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.4 +SMD capacitor, aluminum electrolytic, Panasonic B45, 5.0x4.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.3 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 5.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 5.0x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.8 +SMD capacitor, aluminum electrolytic, Panasonic, 5.0x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_5x5.9 +SMD capacitor, aluminum electrolytic, Panasonic B6, 5.0x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x3.9 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x3.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.5 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x4.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x4.9 +SMD capacitor, aluminum electrolytic, Panasonic C5, 6.3x4.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.2 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.3 +SMD capacitor, aluminum electrolytic, Cornell Dubilier, 6.3x5.3mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic, Panasonic C55, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.4_Nichicon +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 6.3x5.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x5.8mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x5.9 +SMD capacitor, aluminum electrolytic, Panasonic C6, 6.3x5.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 6.3x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_6.3x9.9 +SMD capacitor, aluminum electrolytic, Panasonic C10, 6.3x9.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x5.4 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x5.4mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.2 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x6.2mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.5 +SMD capacitor, aluminum electrolytic, Rubycon, 8.0x6.5mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.7 +SMD capacitor, aluminum electrolytic, United Chemi-Con, 8.0x6.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x6.9 +SMD capacitor, aluminum electrolytic, Panasonic E7, 8.0x6.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10 +SMD capacitor, aluminum electrolytic, Nichicon, 8.0x10mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x10.5 +SMD capacitor, aluminum electrolytic, Vishay 0810, 8.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_8x11.9 +SMD capacitor, aluminum electrolytic, Panasonic E12, 8.0x11.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.7 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x7.7mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x7.9 +SMD capacitor, aluminum electrolytic, Panasonic F8, 10.0x7.9mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10 +SMD capacitor, aluminum electrolytic, Nichicon, 10.0x10.0mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x10.5 +SMD capacitor, aluminum electrolytic, Vishay 1010, 10.0x10.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.5 +SMD capacitor, aluminum electrolytic, Vishay 1012, 10.0x12.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x12.6 +SMD capacitor, aluminum electrolytic, Panasonic F12, 10.0x12.6mm +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_10x14.3 +SMD capacitor, aluminum electrolytic, Vishay 1014, 10.0x14.3mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1616, 16.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_16x22 +SMD capacitor, aluminum electrolytic, Vishay 1621, 16.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x17.5 +SMD capacitor, aluminum electrolytic, Vishay 1816, 18.0x17.5mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +CP_Elec_18x22 +SMD capacitor, aluminum electrolytic, Vishay 1821, 18.0x22.0mm, http://www.vishay.com/docs/28395/150crz.pdf +capacitor electrolytic +0 +2 +2 +Capacitor_SMD +C_0201_0603Metric +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_0201_0603Metric_Pad0.64x0.40mm_HandSolder +Capacitor SMD 0201 (0603 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: https://www.vishay.com/docs/20052/crcw0201e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_0402_1005Metric +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0402_1005Metric_Pad0.74x0.62mm_HandSolder +Capacitor SMD 0402 (1005 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0504_1310Metric_Pad0.83x1.28mm_HandSolder +Capacitor SMD 0504 (1310 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0603_1608Metric_Pad1.08x0.95mm_HandSolder +Capacitor SMD 0603 (1608 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_0805_2012Metric_Pad1.18x1.45mm_HandSolder +Capacitor SMD 0805 (2012 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf, https://docs.google.com/spreadsheets/d/1BsfQQcO9C6DZCsRaXUlFlo91Tg2WpOkGARC1WS5S8t0/edit?usp=sharing), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_01005_0402Metric +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor +0 +4 +2 +Capacitor_SMD +C_01005_0402Metric_Pad0.57x0.30mm_HandSolder +Capacitor SMD 01005 (0402 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.vishay.com/docs/20056/crcw01005e3.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +4 +2 +Capacitor_SMD +C_1206_3216Metric +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1206_3216Metric_Pad1.33x1.80mm_HandSolder +Capacitor SMD 1206 (3216 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1210_3225Metric_Pad1.33x2.70mm_HandSolder +Capacitor SMD 1210 (3225 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1812_4532Metric_Pad1.57x3.40mm_HandSolder +Capacitor SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_1825_4564Metric_Pad1.57x6.80mm_HandSolder +Capacitor SMD 1825 (4564 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: IPC-SM-782 page 76, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2220_5650Metric_Pad1.97x5.40mm_HandSolder +Capacitor SMD 2220 (5650 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_2225_5664Metric_Pad1.80x6.60mm_HandSolder +Capacitor SMD 2225 (5664 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal, (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor +0 +2 +2 +Capacitor_SMD +C_3640_9110Metric_Pad2.10x10.45mm_HandSolder +Capacitor SMD 3640 (9110 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size from: http://datasheets.avx.com/AVX-HV_MLCC.pdf), generated with kicad-footprint-generator +capacitor handsolder +0 +2 +2 +Capacitor_SMD +C_Elec_3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 3.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_4x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 4.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_5x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 5.0x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x5.8 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x5.8mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_6.3x7.7 +SMD capacitor, aluminum electrolytic nonpolar, 6.3x7.7mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x5.4 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x5.4mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x6.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x6.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_8x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 8.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Elec_10x10.2 +SMD capacitor, aluminum electrolytic nonpolar, 10.0x10.2mm +capacitor electrolyic nonpolar +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-A +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZB4-B +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZB4 TZB4-A +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZC3 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZR1 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZR1 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZW4 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZW4 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Murata_TZY2 +trimmer capacitor SMD horizontal, http://www.murata.com/~/media/webrenewal/support/library/catalog/products/capacitor/trimmer/t13e.ashx?la=en-gb + Murata TZY2 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Sprague-Goodman_SGC3 +trimmer capacitor SMD horizontal, http://media.wix.com/ugd/d86717_38d9821e12823a7aa9cef38c6c2a73cc.pdf + Sprague Goodman SGC3 +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JN +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JN +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JQ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JQ +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JR +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JV +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JV +0 +2 +2 +Capacitor_SMD +C_Trimmer_Voltronics_JZ +trimmer capacitor SMD horizontal, http://www.knowlescapacitors.com/File%20Library/Voltronics/English/GlobalNavigation/Products/Trimmer%20Capacitors/CerChipTrimCap.pdf + Voltronics JR +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D4.5mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*4.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 4.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L10.0mm_D6.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=10*6mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 10mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D5.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*5mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D6.0mm_P18.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=18mm, , length*diameter=11*6mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 18mm length 11mm diameter 6mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L11.0mm_D8.0mm_P15.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=11*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 15mm length 11mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D6.5mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*6.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 6.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D8.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*8mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L18.0mm_D10.0mm_P25.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=18*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 25mm length 18mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D10.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L20.0mm_D13.0mm_P26.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=26mm, , length*diameter=20*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 26mm length 20mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L21.0mm_D8.0mm_P28.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=28mm, , length*diameter=21*8mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 28mm length 21mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L25.0mm_D10.0mm_P30.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=30mm, , length*diameter=25*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 30mm length 25mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L26.5mm_D20.0mm_P33.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=33mm, , length*diameter=26.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 33mm length 26.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*10mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D13.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D16.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L29.0mm_D20.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=29*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 29mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D10.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*10mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D12.5mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*12.5mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D15.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*15mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 15mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L30.0mm_D18.0mm_P35.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=35mm, , length*diameter=30*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 35mm length 30mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L34.5mm_D20.0mm_P41.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=41mm, , length*diameter=34.5*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 41mm length 34.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D13.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*13mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D16.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*16mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L37.0mm_D20.0mm_P43.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=43mm, , length*diameter=37*20mm^2, Electrolytic Capacitor, , http://www.kemet.com/Lists/ProductCatalog/Attachments/424/KEM_AC102.pdf +CP Axial series Axial Horizontal pin pitch 43mm length 37mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D18.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*18mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L38.0mm_D21.0mm_P44.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=44mm, , length*diameter=38*21mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/28325/021asm.pdf +CP Axial series Axial Horizontal pin pitch 44mm length 38mm diameter 21mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L40.0mm_D16.0mm_P48.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=48mm, , length*diameter=40*16mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 48mm length 40mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D23.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D26.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D29.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D32.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.0mm_D35.0mm_P45.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=45mm, , length*diameter=42*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 45mm length 42mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L42.5mm_D20.0mm_P49.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=49mm, , length*diameter=42.5*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 49mm length 42.5mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L46.0mm_D20.0mm_P52.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=52mm, , length*diameter=46*20mm^2, Electrolytic Capacitor +CP Axial series Axial Horizontal pin pitch 52mm length 46mm diameter 20mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D23.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D26.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D29.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D32.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L55.0mm_D35.0mm_P60.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=60mm, , length*diameter=55*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 60mm length 55mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D23.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D26.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D29.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D32.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L67.0mm_D35.0mm_P75.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=75mm, , length*diameter=67*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 75mm length 67mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D23.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D26.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D29.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D32.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L80.0mm_D35.0mm_P85.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=85mm, , length*diameter=80*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 85mm length 80mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D23.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*23.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 23.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D26.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*26mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D29.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*29.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 29.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D32.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*32.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 32.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Axial_L93.0mm_D35.0mm_P100.00mm_Horizontal +CP, Axial series, Axial, Horizontal, pin pitch=100mm, , length*diameter=93*35.0mm^2, Electrolytic Capacitor, , http://www.vishay.com/docs/42037/53d.pdf +CP Axial series Axial Horizontal pin pitch 100mm length 93mm diameter 35.0mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P1.50mm +CP, Radial series, Radial, pin pitch=1.50mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 1.50mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D4.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=4mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 4mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.00mm +CP, Radial series, Radial, pin pitch=2.00mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.00mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D5.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D6.3mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=6.3mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 6.3mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D7.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=7.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 7.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D8.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=8mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 8mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P2.50mm_P5.00mm +CP, Radial series, Radial, pin pitch=2.50mm 5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm 5.00mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.50mm +CP, Radial series, Radial, pin pitch=3.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P3.80mm +CP, Radial series, Radial, pin pitch=3.80mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 3.80mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D10.0mm_P5.00mm_P7.50mm +CP, Radial series, Radial, pin pitch=5.00mm 7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm 7.50mm diameter 10mm Electrolytic Capacitor +0 +4 +2 +Capacitor_THT +CP_Radial_D10.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=10mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 10mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D12.5mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=12.5mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 12.5mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P2.50mm +CP, Radial series, Radial, pin pitch=2.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 2.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D13.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=13mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 13mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 5.00mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D14.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=14mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 14mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D16.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=16mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 16mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D17.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=17mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 17mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D18.0mm_P7.50mm +CP, Radial series, Radial, pin pitch=7.50mm, , diameter=18mm, Electrolytic Capacitor +CP Radial series Radial pin pitch 7.50mm diameter 18mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D22.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=22mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 22mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D24.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=24mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 24mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D25.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=25mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 25mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D26.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=26mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 26mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D30.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=30mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 30mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D35.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=35mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 35mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_3pin_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +3 +2 +Capacitor_THT +CP_Radial_D40.0mm_P10.00mm_SnapIn +CP, Radial series, Radial, pin pitch=10.00mm, , diameter=40mm, Electrolytic Capacitor, , http://www.vishay.com/docs/28342/058059pll-si.pdf +CP Radial series Radial pin pitch 10.00mm diameter 40mm Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D4.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=4.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 4.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D5.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=5.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 5.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D6.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=6.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 6.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D7.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=7.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 7.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D8.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=8.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 8.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D9.0mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=9.0mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 9.0mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P2.50mm +CP, Radial_Tantal series, Radial, pin pitch=2.50mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 2.50mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +CP_Radial_Tantal_D10.5mm_P5.00mm +CP, Radial_Tantal series, Radial, pin pitch=5.00mm, , diameter=10.5mm, Tantal Electrolytic Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/TANTAL-TB-Serie%23.pdf +CP Radial_Tantal series Radial pin pitch 5.00mm diameter 10.5mm Tantal Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L3.8mm_D2.6mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=3.8*2.6mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 3.8mm diameter 2.6mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P7.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=7.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 7.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P10.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=10mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 10mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P12.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=12.5mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 12.5mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L5.1mm_D3.1mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=5.1*3.1mm^2, http://www.vishay.com/docs/45231/arseries.pdf +C Axial series Axial Horizontal pin pitch 15mm length 5.1mm diameter 3.1mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D7.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D8.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*8.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 8.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D9.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P15.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=15mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 15mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L12.0mm_D10.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=12*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 12mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D6.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*6.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 6.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P20.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=20mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 20mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L17.0mm_D7.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=17*7.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 17mm diameter 7.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D7.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*7.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 7.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D8.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*8.0mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 8.0mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.0mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9mm +0 +2 +2 +Capacitor_THT +C_Axial_L19.0mm_D9.5mm_P25.00mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=25mm, , length*diameter=19*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 25mm length 19mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D9.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*9.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 9.5mm +0 +2 +2 +Capacitor_THT +C_Axial_L22.0mm_D10.5mm_P27.50mm_Horizontal +C, Axial series, Axial, Horizontal, pin pitch=27.5mm, , length*diameter=22*10.5mm^2, http://cdn-reichelt.de/documents/datenblatt/B300/STYROFLEX.pdf +C Axial series Axial Horizontal pin pitch 27.5mm length 22mm diameter 10.5mm +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W1.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.0*1.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.0mm width 1.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.0mm_W2.0mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3*2mm^2, Capacitor +C Disc series Radial pin pitch 2.50mm diameter 3mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.4mm_W2.1mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.4*2.1mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.4mm width 2.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D3.8mm_W2.6mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=3.8*2.6mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 2.50mm diameter 3.8mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.3mm_W1.9mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.3*1.9mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.3mm width 1.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D4.7mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=4.7*2.5mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 4.7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P2.50mm +C, Disc series, Radial, pin pitch=2.50mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 2.50mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D5.1mm_W3.2mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=5.1*3.2mm^2, Capacitor, http://www.vishay.com/docs/45233/krseries.pdf +C Disc series Radial pin pitch 5.00mm diameter 5.1mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 6mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D6.0mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=6*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 6mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*2.5mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W4.4mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*4.4mm^2, Capacitor +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D7.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=7.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 7.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D8.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=8*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 8mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D9.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=9*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 9mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.0mm_W2.5mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10*2.5mm^2, Capacitor, http://cdn-reichelt.de/documents/datenblatt/B300/DS_KERKO_TC.pdf +C Disc series Radial pin pitch 5.00mm diameter 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D10.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=10.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 10.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P5.00mm +C, Disc series, Radial, pin pitch=5.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 5.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D11.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=11*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 11mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.0mm_W4.4mm_P7.75mm +C, Disc series, Radial, pin pitch=7.75mm, , diameter*width=12*4.4mm^2, Capacitor +C Disc series Radial pin pitch 7.75mm diameter 12mm width 4.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D12.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=12.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 12.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D14.5mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=14.5*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 14.5mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P7.50mm +C, Disc series, Radial, pin pitch=7.50mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 7.50mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Disc_D16.0mm_W5.0mm_P10.00mm +C, Disc series, Radial, pin pitch=10.00mm, , diameter*width=16.0*5.0mm^2, Capacitor, http://www.vishay.com/docs/28535/vy2series.pdf +C Disc series Radial pin pitch 10.00mm diameter 16.0mm width 5.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H5.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D4.0mm_H7.0mm_P1.50mm +C, Radial series, Radial, pin pitch=1.50mm, diameter=4mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 1.50mm diameter 4mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H5.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H7.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D5.0mm_H11.0mm_P2.00mm +C, Radial series, Radial, pin pitch=2.00mm, diameter=5mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.00mm diameter 5mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H5.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H7.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D6.3mm_H11.0mm_P2.50mm +C, Radial series, Radial, pin pitch=2.50mm, diameter=6.3mm, height=11mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 2.50mm diameter 6.3mm height 11mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H7.0mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=7mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 7mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D8.0mm_H11.5mm_P3.50mm +C, Radial series, Radial, pin pitch=3.50mm, diameter=8mm, height=11.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 3.50mm diameter 8mm height 11.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H12.5mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=12.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 12.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H16.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=16mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 16mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D10.0mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=10mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 10mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H20.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=20mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 20mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D12.5mm_H25.0mm_P5.00mm +C, Radial series, Radial, pin pitch=5.00mm, diameter=12.5mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 5.00mm diameter 12.5mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H25.0mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=25mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 25mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D16.0mm_H31.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=16mm, height=31.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 16mm height 31.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Radial_D18.0mm_H35.5mm_P7.50mm +C, Radial series, Radial, pin pitch=7.50mm, diameter=18mm, height=35.5mm, Non-Polar Electrolytic Capacitor +C Radial series Radial pin pitch 7.50mm diameter 18mm height 35.5mm Non-Polar Electrolytic Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.0mm_W2.5mm_P2.50mm +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4*2.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm length 4mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W2.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*2mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.0mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.0mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W3.8mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*3.8mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W4.6mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*4.6mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 4.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L4.6mm_W5.5mm_P2.50mm_MKS02_FKP02 +C, Rect series, Radial, pin pitch=2.50mm, , length*width=4.6*5.5mm^2, Capacitor, http://www.wima.de/DE/WIMA_MKS_02.pdf +C Rect series Radial pin pitch 2.50mm length 4.6mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W2.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*2.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P2.50mm_P5.00mm +C, Rect series, Radial, pin pitch=2.50mm 5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 2.50mm 5.00mm length 7mm width 3.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L7.0mm_W3.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*3.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W4.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*4.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.0mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.0mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W2.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W3.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*3.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W4.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W5.5mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*5.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 5.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W7.2mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W8.5mm_P5.00mm_FKP2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.2mm_W11.0mm_P5.00mm_FKS2_FKP2_MKS2_MKP2 +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.2*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_2.pdf +C Rect series Radial pin pitch 5.00mm length 7.2mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L7.5mm_W6.5mm_P5.00mm +C, Rect series, Radial, pin pitch=5.00mm, , length*width=7.5*6.5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm length 7.5mm width 6.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W2.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*2.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 2.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.3mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.6mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W3.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*3.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 3.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.0mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.2mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W4.9mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.1mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W5.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*5.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.4mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W6.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*6.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 6.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W7.7mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*7.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 7.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W8.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*8.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.5mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L9.0mm_W9.8mm_P7.50mm_MKT +C, Rect series, Radial, pin pitch=7.50mm, , length*width=9*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 7.50mm length 9mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W2.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*2.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 2.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W3.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*3.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 3.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W4.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10*4.0mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.0mm_W5.0mm_P5.00mm_P7.50mm +C, Rect series, Radial, pin pitch=5.00mm 7.50mm, , length*width=10*5mm^2, Capacitor +C Rect series Radial pin pitch 5.00mm 7.50mm length 10mm width 5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L10.3mm_W4.5mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*4.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.0mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W5.7mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*5.7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 5.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L10.3mm_W7.2mm_P7.50mm_MKS4 +C, Rect series, Radial, pin pitch=7.50mm, , length*width=10.3*7.2mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 7.50mm length 10.3mm width 7.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W5.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*5.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 5.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.0mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.0*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.0mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W2.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*2.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 2.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W3.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*3.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 3.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W4.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*4.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 4.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.1mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.2mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W5.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*5.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 5.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.4mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.4mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.6mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W6.9mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*6.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 6.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.3mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W7.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.0mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.0mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.0mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W8.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*8.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 8.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.5mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L11.5mm_W9.8mm_P10.00mm_MKT +C, Rect series, Radial, pin pitch=10.00mm, , length*width=11.5*9.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 10.00mm length 11.5mm width 9.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W3.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*3mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.0mm_W6.5mm_P7.50mm_P10.00mm +C, Rect series, Radial, pin pitch=7.50mm 10.00mm, , length*width=13*6.5mm^2, Capacitor +C Rect series Radial pin pitch 7.50mm 10.00mm length 13mm width 6.5mm Capacitor +0 +4 +2 +Capacitor_THT +C_Rect_L13.0mm_W8.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W4.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*4mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 4mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L13.5mm_W5.0mm_P10.00mm_FKS3_FKP3_MKS4 +C, Rect series, Radial, pin pitch=10.00mm, , length*width=13.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 10.00mm length 13.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W4.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*4.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 4.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W5.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W6.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W7.3mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*7.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 7.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W8.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*8.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 8.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.0mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W9.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*9.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 9.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W10.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.2mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W11.8mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*11.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 11.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.5mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.5mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.7mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L16.5mm_W13.9mm_P15.00mm_MKT +C, Rect series, Radial, pin pitch=15.00mm, , length*width=16.5*13.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 15.00mm length 16.5mm width 13.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W5.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W6.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W7.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W8.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W9.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L18.0mm_W11.0mm_P15.00mm_FKS3_FKP3 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=18*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_FKS_3.pdf +C Rect series Radial pin pitch 15.00mm length 18mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W5.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W6.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W7.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W8.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W9.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L19.0mm_W11.0mm_P15.00mm_MKS4 +C, Rect series, Radial, pin pitch=15.00mm, , length*width=19*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 15.00mm length 19mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W7.0mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*7mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W8.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*8.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 8.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.1mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.3mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.3mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.3mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W10.9mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*10.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 10.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.2mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.6mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L24.0mm_W12.8mm_P22.50mm_MKT +C, Rect series, Radial, pin pitch=22.50mm, , length*width=24*12.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 22.50mm length 24mm width 12.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W5.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W6.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*6mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W7.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*7mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 7mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W8.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*8.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 8.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W10.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*10.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 10.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L26.5mm_W11.5mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=26.5*11.5mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 26.5mm width 11.5mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W9.0mm_P23.00mm +C, Rect series, Radial, pin pitch=23.00mm, , length*width=27*9mm^2, Capacitor +C Rect series Radial pin pitch 23.00mm length 27mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L27.0mm_W11.0mm_P22.00mm +C, Rect series, Radial, pin pitch=22.00mm, , length*width=27*11mm^2, Capacitor +C Rect series Radial pin pitch 22.00mm length 27mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W8.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*8mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W10.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*10mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 10mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L28.0mm_W12.0mm_P22.50mm_MKS4 +C, Rect series, Radial, pin pitch=22.50mm, , length*width=28*12mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 22.50mm length 28mm width 12mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W7.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*7.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 7.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.1mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.1mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.1mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W9.6mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*9.6mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 9.6mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W11.9mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*11.9mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 11.9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W12.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*12.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 12.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W13.8mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*13.8mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 13.8mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W14.2mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*14.2mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 14.2mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L29.0mm_W16.0mm_P27.50mm_MKT +C, Rect series, Radial, pin pitch=27.50mm, , length*width=29*16mm^2, Capacitor, https://en.tdk.eu/inf/20/20/db/fc_2009/MKT_B32560_564.pdf +C Rect series Radial pin pitch 27.50mm length 29mm width 16mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W9.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W11.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W17.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L31.5mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=31.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 31.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L32.0mm_W15.0mm_P27.00mm +C, Rect series, Radial, pin pitch=27.00mm, , length*width=32*15mm^2, Capacitor +C Rect series Radial pin pitch 27.00mm length 32mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W13.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W15.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L33.0mm_W20.0mm_P27.50mm_MKS4 +C, Rect series, Radial, pin pitch=27.50mm, , length*width=33*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 27.50mm length 33mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W9.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*9mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 9mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W11.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*11mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 11mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W13.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*13mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 13mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W15.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*15mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 15mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W17.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*17mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 17mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W19.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*19mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 19mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W20.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*20mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 20mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W24.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*24mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 24mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W31.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*31mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 31mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W35.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*35mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 35mm Capacitor +0 +2 +2 +Capacitor_THT +C_Rect_L41.5mm_W40.0mm_P37.50mm_MKS4 +C, Rect series, Radial, pin pitch=37.50mm, , length*width=41.5*40mm^2, Capacitor, http://www.wima.com/EN/WIMA_MKS_4.pdf +C Rect series Radial pin pitch 37.50mm length 41.5mm width 40mm Capacitor +0 +2 +2 +Capacitor_THT +DX_5R5HxxxxU_D11.5mm_P10.00mm +CP, Radial series, Radial, pin pitch=10.00mm, diameter=11.5mm, Supercapacitor, http://www.elna.co.jp/en/capacitor/double_layer/catalog/pdf/dx_e.pdf +CP Radial series Radial pin pitch 10.00mm diameter 11.5mm supercapacitor +0 +2 +2 +Capacitor_THT +DX_5R5VxxxxU_D11.5mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, diameter=11.5mm, Supercapacitor, http://www.elna.co.jp/en/capacitor/double_layer/catalog/pdf/dx_e.pdf +CP Radial series Radial pin pitch 5.00mm diameter 11.5mm supercapacitor +0 +2 +2 +Capacitor_THT +DX_5R5VxxxxU_D19.0mm_P5.00mm +CP, Radial series, Radial, pin pitch=5.00mm, diameter=19mm, Supercapacitor, http://www.elna.co.jp/en/capacitor/double_layer/catalog/pdf/dx_e.pdf +CP Radial series Radial pin pitch 5.00mm diameter 19mm supercapacitor +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-08_AVX-J_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-J (1608-08 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-1608-10_AVX-L_Pad1.25x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-L (1608-10 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/48064/_t58_vmn_pt0471_1601.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-12_Kemet-R_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD Kemet-R (2012-12 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-2012-15_AVX-P_Pad1.30x1.05mm_HandSolder +Tantalum Capacitor SMD AVX-P (2012-15 Metric), IPC_7351 nominal, (Body size from: https://www.vishay.com/docs/40182/tmch.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-10_Kemet-I_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-I (3216-10 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-12_Kemet-S_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-S (3216-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3216-18_Kemet-A_Pad1.58x1.35mm_HandSolder +Tantalum Capacitor SMD Kemet-A (3216-18 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-12_Kemet-T_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-T (3528-12 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-15_AVX-H_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-H (3528-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-3528-21_Kemet-B_Pad1.50x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-B (3528-21 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-15_Kemet-U_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-U (6032-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-20_AVX-F_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD AVX-F (6032-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-6032-28_Kemet-C_Pad2.25x2.35mm_HandSolder +Tantalum Capacitor SMD Kemet-C (6032-28 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-20_AVX-U_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-U (7132-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7132-28_AVX-C_Pad2.72x3.50mm_HandSolder +Tantalum Capacitor SMD AVX-C (7132-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-15_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-15 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-20_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-20 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-28_AVX-M_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-M (7260-28 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7260-38_AVX-R_Pad2.68x6.30mm_HandSolder +Tantalum Capacitor SMD AVX-R (7260-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/F72-F75.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-15_Kemet-W_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-W (7343-15 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-20_Kemet-V_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-V (7343-20 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-30_AVX-N_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD AVX-N (7343-30 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-31_Kemet-D_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-D (7343-31 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-40_Kemet-Y_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-Y (7343-40 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7343-43_Kemet-X_Pad2.25x2.55mm_HandSolder +Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7360-38_Kemet-E_Pad2.25x4.25mm_HandSolder +Tantalum Capacitor SMD Kemet-E (7360-38 Metric), IPC_7351 nominal, (Body size from: http://www.kemet.com/Lists/ProductCatalog/Attachments/253/KEM_TC101_STD.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-38_AVX-V_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-V (7361-38 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Capacitor_Tantalum_SMD +CP_EIA-7361-438_AVX-U_Pad2.18x3.30mm_HandSolder +Tantalum Capacitor SMD AVX-U (7361-438 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/NOS.pdf), generated with kicad-footprint-generator +capacitor tantalum +0 +2 +2 +Connector +Banana_Jack_1Pin +Single banana socket, footprint - 6mm drill +banana socket +0 +1 +1 +Connector +Banana_Jack_2Pin +Dual banana socket, footprint - 2 x 6mm drills +banana socket +0 +2 +2 +Connector +Banana_Jack_3Pin +Triple banana socket, footprint - 3 x 6mm drills +banana socket +0 +3 +3 +Connector +CUI_PD-30 +3 pin connector, PD-30, http://www.cui.com/product/resource/pd-30.pdf +connector 3-pin PD-30 power DIN +0 +4 +4 +Connector +CUI_PD-30S +3-pin nonstandard DIN connector, shielded, PD-30S, http://www.cui.com/product/resource/pd-30s.pdf +connector 3-pin PD-30S power DIN shielded +0 +8 +5 +Connector +CUI_PD-30S_CircularHoles +3-pin nonstandard DIN connector, shielded, PD-30S, http://www.cui.com/product/resource/pd-30s.pdf +connector 3-pin PD-30S power DIN shielded +0 +8 +5 +Connector +CalTest_CT3151 +Right-angle standard banana jack, http://www.caltestelectronics.com/images/attachments/P315100rH_drawing.pdf +banana jack horizontal +0 +4 +1 +Connector +Connector_SFP_and_Cage +https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=2227302&DocType=Customer+Drawing&DocLang=English +SFP+ SFP +0 +40 +21 +Connector +DTF13-12Px +http://www.te.com/usa-en/product-DTF13-12PA-G003.html +DEUTSCH DT header 12 pin +0 +12 +12 +Connector +FanPinHeader_1x03_P2.54mm_Vertical +3-pin CPU fan Through hole pin header, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 3-pin CPU fan +0 +3 +3 +Connector +FanPinHeader_1x04_P2.54mm_Vertical +4-pin CPU fan Through hole pin header, e.g. for Wieson part number 2366C888-007 Molex 47053-1000, Foxconn HF27040-M1, Tyco 1470947-1 or equivalent, see http://www.formfactors.org/developer%5Cspecs%5Crev1_2_public.pdf +pin header 4-pin CPU fan +0 +4 +4 +Connector +GB042-34S-H10 +http://www.lsmtron.com/pdf/Connector&Antenna_catalog.PDF +34pin SMD connector +0 +34 +34 +Connector +IHI_B6A-PCB-45_Vertical +https://lugsdirect.com/PDF_Webprint/B6A-PCB-45-XX(-X).pdf +connector IHI B6A-PCB-45 +0 +49 +1 +Connector +JWT_A3963_1x02_P3.96mm_Vertical +JWT A3963, 3.96mm pitch Pin head connector (http://www.jwt.com.tw/pro_pdf/A3963.pdf) +connector JWT A3963 pinhead +0 +2 +2 +Connector +NS-Tech_Grove_1x04_P2mm_Vertical +https://statics3.seeedstudio.com/images/opl/datasheet/3470130P1.pdf +Grove-1x04 +0 +4 +4 +Connector +SpringContact_Harwin_S1941-46R +7.25mm SMT Multi-directional Spring Contact (T+R), https://cdn.harwin.com/pdfs/S1941R.pdf +spring contact emi emc shield +0 +1 +1 +Connector +Tag-Connect_TC2030-IDC-FP_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2030-IDC-NL_2x03_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2030-IDC-NL.pdf +tag connect programming header pogo pins +0 +6 +6 +Connector +Tag-Connect_TC2050-IDC-FP_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-430%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2050-IDC-NL%20Datasheet.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2050-IDC-NL_2x05_P1.27mm_Vertical_with_bottom_clip +Tag-Connect programming header with bottom courtyard for TC2050-NL Clip board ; https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-IDC-NL_Datasheet_8.pdf https://www.tag-connect.com/wp-content/uploads/bsk-pdf-manager/TC2050-CLIP_Datasheet_25.pdf +tag connect programming header pogo pins +0 +10 +10 +Connector +Tag-Connect_TC2070-IDC-FP_2x07_P1.27mm_Vertical +Tag-Connect programming header; http://www.tag-connect.com/Materials/TC2070-IDC%20Datasheet.pdf +tag connect programming header pogo pins +0 +14 +14 +Connector_AMASS +AMASS_MR30PW-FB_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_MR30PW-M_1x03_P3.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/5e47640ba39fa492dbd4c0f4c8ae7b93/MR30PW%20SPEC.pdf +RC Connector XT30 +0 +5 +3 +Connector_AMASS +AMASS_XT30PW-F_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Female, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30PW-M_1x02_P2.50mm_Horizontal +Connector XT30 Horizontal PCB Male, https://www.tme.eu/en/Document/ce4077e36b79046da520ca73227e15de/XT30PW%20SPEC.pdf +RC Connector XT30 +0 +4 +2 +Connector_AMASS +AMASS_XT30U-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Female, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30U-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical Cable Male, https://www.tme.eu/en/Document/3cbfa5cfa544d79584972dd5234a409e/XT30U%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-F_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Female, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT30UPB-M_1x02_P5.0mm_Vertical +Connector XT30 Vertical PCB Male, https://www.tme.eu/en/Document/4acc913878197f8c2e30d4b8cdc47230/XT30UPB%20SPEC.pdf +RC Connector XT30 +0 +2 +2 +Connector_AMASS +AMASS_XT60-F_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_AMASS +AMASS_XT60-M_1x02_P7.20mm_Vertical +AMASS female XT60, through hole, vertical, https://www.tme.eu/Document/2d152ced3b7a446066e6c419d84bb460/XT60%20SPEC.pdf +XT60 female vertical +0 +2 +2 +Connector_Amphenol +Amphenol_M8S-03PMMR-SF8001 +M8 Male connector for panel, 90° PCB mount (https://www.amphenolltw.com/2012download/2D%20PDF/03_M%20Series%20Sensor%20Connectors/M8S-XXPMMR-SF8001.pdf) +three-pin M8 +0 +5 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ-3523-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ-3524-SMT_Horizontal +3.5 mm, Stereo, Right Angle, Surface Mount (SMT), Audio Jack Connector (https://www.cui.com/product/resource/sj-352x-smt-series.pdf) +3.5mm audio cui horizontal jack stereo +0 +4 +4 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal +TRS 3.5mm, horizontal, through-hole, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3533NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, , circular holeshttps://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +3 +3 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal +TRS 3.5mm, horizontal, through-hole, with switch, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal +0 +5 +5 +Connector_Audio +Jack_3.5mm_CUI_SJ1-3535NG_Horizontal_CircularHoles +TRS 3.5mm, horizontal, through-hole, with switch, circular holes, https://www.cui.com/product/resource/sj1-353xng.pdf +TRS audio jack stereo horizontal circular +0 +5 +5 +Connector_Audio +Jack_3.5mm_Ledino_KB3SPRS_Horizontal +https://www.reichelt.de/index.html?ACTION=7&LA=3&OPEN=0&INDEX=0&FILENAME=C160%252FKB3SPRS.pdf +jack stereo TRS +0 +5 +5 +Connector_Audio +Jack_3.5mm_Lumberg_1503_07_Horizontal +TRS 3.5mm, horizontal, through-hole, https://downloads.lumberg.com/datenblaetter/en/1503_07.pdf +TRS audio jack horizontal +0 +4 +3 +Connector_Audio +Jack_3.5mm_PJ311_Horizontal +PJ311 6pin SMD 3.5mm stereo headphones jack. +headphones jack plug stereo 3.5mm PJ311 +0 +6 +6 +Connector_Audio +Jack_3.5mm_PJ320D_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320D-72.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +4 +4 +Connector_Audio +Jack_3.5mm_PJ320E_Horizontal +Headphones with microphone connector, 3.5mm, 4 pins (http://www.qingpu-electronics.com/en/products/WQP-PJ320E-177.html) +3.5mm jack mic microphone phones headphones 4pins audio plug +0 +5 +4 +Connector_Audio +Jack_3.5mm_PJ31060-I_Horizontal +PJ31060-I 6pin SMD 3.5mm headphones jack (http://www.china-bsun.com/Product48/1577.html) +headphones jack plug stereo 3.5mm PJ31060-I PJ31060 +0 +6 +6 +Connector_Audio +Jack_3.5mm_QingPu_WQP-PJ398SM_Vertical_CircularHoles +TRS 3.5mm, vertical, Thonkiconn, PCB mount, (http://www.qingpu-electronics.com/en/products/WQP-PJ398SM-362.html) +WQP-PJ398SM WQP-PJ301M-12 TRS 3.5mm mono vertical jack thonkiconn qingpu +0 +3 +3 +Connector_Audio +Jack_3.5mm_Switronic_ST-005-G_horizontal +3.5mm horizontal headphones jack, http://akizukidenshi.com/download/ds/switronic/ST-005-G.pdf +Connector Audio Switronic ST-005-G +0 +4 +3 +Connector_Audio +Jack_3.5mm_Technik_TWP-3002_Horizontal +3.5mm Horizontal Waterproof Stereo Headphones Jack, https://www.technik.com.hk/images/pdf_product/WP3002-PA66-A.pdf +audio jack stereo horizontal waterproof +0 +7 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NJ2FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching mono jack (T/S), https://www.neutrik.com/en/product/nj2fd-v +neutrik jack vertical +0 +2 +2 +Connector_Audio +Jack_6.35mm_Neutrik_NJ3FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, Non-switching stereo jack (T/R/S), https://www.neutrik.com/en/product/nj3fd-v +neutrik jack vertical +0 +3 +3 +Connector_Audio +Jack_6.35mm_Neutrik_NJ5FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 2 x switching (normalling) stereo jack (T/TN/R/RN/S), https://www.neutrik.com/en/product/nj5fd-v +neutrik jack vertical +0 +5 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6FD-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6fd-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NJ6TB-V_Vertical +6.35mm (1/4 in) Vertical Jack, 3 x switching (normalling) stereo jack B-gauge type (T/TN/R/RN/S/SN), https://www.neutrik.com/en/product/nj6tb-v +neutrik jack vertical +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HCD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj4hcd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj4hfd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HFD3_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hfd3 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ4HHD2_Horizontal +M Series, 6.35mm (1/4in) mono jack, switched, with a half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj4hhd2 +neutrik jack m +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and straight PCB pins, https://www.neutrik.com/en/product/nmj6hcd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HCD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with chrome ferrule and offset PCB pins, https://www.neutrik.com/en/product/nmj6hcd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2-AU_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, full threaded nose, straight PCB pins, gold plated contacts, https://www.neutrik.com/en/product/nmj6hfd2-au +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and straight PCB pins, https://www.neutrik.com/en/product/nmj6hfd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD3_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hfd3 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HFD4_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with full threaded nose and fishtail PCB pins, https://www.neutrik.com/en/product/nmj6hfd4 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NMJ6HHD2_Horizontal +M Series, 6.35mm (1/4in) stereo jack, switched, with half threaded nose and offset PCB pins, https://www.neutrik.com/en/product/nmj6hhd2 +neutrik jack m +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ3HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, unswitched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj3hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hf-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HF_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj4hf +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj4hh-1 +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ4HH_Horizontal +Slim Jacks, 6.35mm (1/4in) mono jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj4hh +neutrik jack slim +0 +4 +4 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hf-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HF_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, fully threaded nose, https://www.neutrik.com/en/product/nrj6hf +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, sleeve contact/front panel connection, https://www.neutrik.com/en/product/nrj6hh-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, gold plated contacts, half threaded nose, https://www.neutrik.com/en/product/nrj6hh-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HH_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, switched, half threaded nose, https://www.neutrik.com/en/product/nrj6hh +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-AU_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, gold plated contacts, efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-au +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1-PRE_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose, efficient chassis ground connection, T+R normalling contact, https://www.neutrik.com/en/product/nrj6hm-1-pre +neutrik jack slim +0 +6 +5 +Connector_Audio +Jack_6.35mm_Neutrik_NRJ6HM-1_Horizontal +Slim Jacks, 6.35mm (1/4in) stereo jack, metal nose with efficient chassis ground connection, T+R+S normalling contact, https://www.neutrik.com/en/product/nrj6hm-1 +neutrik jack slim +0 +6 +6 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HC_Horizontal +Stacking Jacks, Mono dual jack, full nose, https://www.neutrik.com/en/product/nsj8hc +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ8HL_Horizontal +Stacking Jacks, Mono dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj8hl +neutrik jack stacking +0 +9 +9 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HC_Horizontal +Stacking Jacks, Stereo dual jack, full nose, https://www.neutrik.com/en/product/nsj12hc +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HF-1_Horizontal +Stacking Jacks, Stereo dual jack, full threaded nose, https://www.neutrik.com/en/product/nsj12hf-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HH-1_Horizontal +Stacking Jacks, Stereo dual jack, half threaded nose, https://www.neutrik.com/en/product/nsj12hh-1 +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_6.35mm_Neutrik_NSJ12HL_Horizontal +Stacking Jacks, Stereo dual jack, quick fix nose, https://www.neutrik.com/en/product/nsj12hl +neutrik jack stacking +0 +13 +13 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj5fi-h-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-h +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj5fi-v-0 +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ5FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) mono jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj5fi-v +neutrik jack combo i +0 +6 +6 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-0_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-h-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H-DA_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-h-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-H_Horizontal +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fa-h +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-0_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fa-v-0 +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V-DA_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/ncj6fa-v-da +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FA-V_Vertical +Combo A series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fa-v +neutrik jack combo a +0 +8 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj6fi-h-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-h +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj6fi-v-0 +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ6FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) stereo jack without switching contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj6fi-v +neutrik jack combo i +0 +7 +7 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, https://www.neutrik.com/en/product/ncj9fi-h-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-h +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, https://www.neutrik.com/en/product/ncj9fi-v-0 +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ9FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj9fi-v +neutrik jack combo i +0 +10 +10 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H-0_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, https://www.neutrik.com/en/product/ncj10fi-h-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-H_Horizontal +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, horizontal PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-h +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V-0_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, https://www.neutrik.com/en/product/ncj10fi-v-0 +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR-6.35mm_Neutrik_NCJ10FI-V_Vertical +Combo I series, 3 pole XLR female receptacle with 6.35mm (1/4in) switching stereo jack and switching ground contact, vertical PCB mount, retention spring, https://www.neutrik.com/en/product/ncj10fi-v +neutrik jack combo i +0 +11 +11 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1-DA_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faah1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH1_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2-0_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faah2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH2_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAH_Horizontal +AA Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faah +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV-0_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-0_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav1-0 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1-DA_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3faav1-da +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV1_Vertical +AA Series, 3 pole female receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2-0_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3faav2-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV2_Vertical +AA Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav2 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAAV_Vertical +AA Series, 3 pole female receptacle, grounding: without ground/shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3faav +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2-DA_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fah2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHL1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fahl1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR1_Horizontal +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2-0_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahr2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAHR2_Horizontal +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3fahr2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAH_Horizontal +A Series, 3 pole female XLR receptacle, grounding: without ground/shell contact, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fah +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav1-0 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav1-da +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV1_Vertical +A Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav1 +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-0_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fav2-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2-DA_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fav2-da +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV2_Vertical +A Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav2 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FAV_Vertical +A Series, 3 pole female XLR receptacle, grounding: without ground / shell contact, vertical PCB mount, https://www.neutrik.com/en/product/nc3fav +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh1-e +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-B_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbh2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-DA_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbh2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2-E_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3fbh2-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBH2_Horizontal +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3fbh2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBHL1_Horizontal +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3fbhl1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-0_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, retention spring, no latch, https://www.neutrik.com/en/product/nc3fbv1-0 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv1-b +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv1-da +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV1_Vertical +B Series, 3 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-B_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3fbv2-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-DA_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc3fbv2-da +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2-SW_Vertical +B Series, 3 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3FBV2_Vertical +B Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3fbv2 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-0_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH-1_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAH_Horizontal +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3maah +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-0_Vertical +AA Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-0 +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV-1_Vertical +AA Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav-1 +neutrik xlr aa +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAAV_Vertical +AA Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3maav +neutrik xlr aa +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAFH-PH_Horizontal +A Series, Chassis connector H female (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mafh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH-0_Horizontal +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHL_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mahl +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAHR_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mahr +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAH_Horizontal +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mah +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAMH-PH_Horizontal +A Series, Chassis connector Phoenix H male (A series layout), horizontal PCB mount, https://www.neutrik.com/en/product/nc4mamh-ph +neutrik xlr a +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV-0_Vertical +A Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav-0 +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MAV_Vertical +A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mav +neutrik xlr a +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-0_Horizontal +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-1_Horizontal +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbh-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH-E_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbh-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhl-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHL_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral left PCB mount, https://www.neutrik.com/en/product/nc3mbhl +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR-B_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbhr-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBHR_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, lateral right PCB mount, https://www.neutrik.com/en/product/nc3mbhr +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBH_Horizontal +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, horizontal PCB mount, https://www.neutrik.com/en/product/nc3mbh +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-0_Vertical +B Series, 3 pole male XLR receptacle, grounding: ground contact connected to shell ground, but not to front panel and Pin 1, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-0 +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-1_Vertical +B Series, 3 pole male XLR receptacle, grounding: mating connector shell to pin1 and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-1 +neutrik xlr b +0 +3 +3 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-B_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc3mbv-b +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-E_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, additional ground contacts, https://www.neutrik.com/en/product/nc3mbv-e +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV-SW_Vertical +B Series, 3 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv-sw +neutrik xlr b +0 +7 +7 +Connector_Audio +Jack_XLR_Neutrik_NC3MBV_Vertical +B Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, steel retention lug, vertical PCB mount, https://www.neutrik.com/en/product/nc3mbv +neutrik xlr b +0 +4 +4 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH-0_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fah-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAH_Horizontal +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV-0_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc4fav-0 +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FAV_Vertical +A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBH_Horizontal +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4fbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4FBV_Vertical +B Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4fbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAH_Horizontal +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mah +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MAV_Vertical +A Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mav +neutrik xlr a +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBH_Horizontal +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc4mbh +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC4MBV_Vertical +B Series, 4 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc4mbv +neutrik xlr b +0 +5 +5 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-0_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc5fah-0 +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH-DA_Horizontal +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fah-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAH_Horizontal +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-DA_Vertical +A Series, 5 pole female XLR receptacle, grounding: mating connector shell to pin1 and front panel, horizontal PCB mount, asymmetric push, https://www.neutrik.com/en/product/nc5fav-da +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV-SW_Vertical +A Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, color coding possible, https://www.neutrik.com/en/product/nc5fav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FAV_Vertical +A Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH-B_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBH_Horizontal +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5fbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-B_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5fbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV-SW_Vertical +B Series, 5 pole female XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5FBV_Vertical +B Series, 5 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5fbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAH_Horizontal +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mah +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV-SW_Vertical +A Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav-sw +neutrik xlr a +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MAV_Vertical +A Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mav +neutrik xlr a +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH-B_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbh-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBH_Horizontal +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc5mbh +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-B_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, black chrome shell, https://www.neutrik.com/en/product/nc5mbv-b +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV-SW_Vertical +B Series, 5 pole male XLR receptacle, switching contacts, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv-sw +neutrik xlr b +0 +9 +9 +Connector_Audio +Jack_XLR_Neutrik_NC5MBV_Vertical +B Series, 5 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, vertical PCB mount, https://www.neutrik.com/en/product/nc5mbv +neutrik xlr b +0 +6 +6 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-H_Horizontal +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, horizontal pcb mount, https://www.neutrik.com/en/product/nlj2md-h +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON-6.35mm_Neutrik_NLJ2MD-V_Vertical +speakON Combo, 2 pole combination of speakON socket and 6.35mm (1/4in) jack receptacle, vertical pcb mount, https://www.neutrik.com/en/product/nlj2md-v +neutrik speakon combo +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-H_Horizontal +speakON Chassis Connectors, 2 pole chassis connector, gray D-size flange, countersunk thru holes, horizontal PCB, https://www.neutrik.com/en/product/nl2md-h +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL2MD-V_Vertical +speakON Chassis Connectors, 2 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl2md-v +neutrik speakon +0 +2 +2 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-1_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-2_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H-3_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h-3 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-H_Horizontal +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), horizontal PCB mount, https://www.neutrik.com/en/product/nl4md-h +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-1_Vertical +speakON Chassis Connectors, 4 pole chassis connector, grey D-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-1 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-2_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, mirrored self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-2 +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-R_Vertical +speakON Chassis Connectors, 4 pole chassis connector, red D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v-r +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V-S_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, switchable version of NL4MD-V with 8 vertical PCB contacts (4 switching contacts), https://www.neutrik.com/en/product/nl4md-v-s +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL4MD-V_Vertical +speakON Chassis Connectors, 4 pole chassis connector, black D-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl4md-v +neutrik speakon +0 +4 +4 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V-1_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, self tapping screw holes (A-screw), vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v-1 +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NL8MD-V_Vertical +speakON Chassis Connectors, 8 pole chassis connector, nickel metal square G-size flange, countersunk thru holes, vertical PCB mount, https://www.neutrik.com/en/product/nl8md-v +neutrik speakon +0 +8 +8 +Connector_Audio +Jack_speakON_Neutrik_NLT4MD-V_Vertical +STX Series, 4 pole male chassis connector, metal housing, vertical PCB mount, self tapping screw holes (A-screw), https://www.neutrik.com/en/product/nlt4md-v +neutrik speakon stx +0 +4 +4 +Connector_Audio +MiniXLR-5_Switchcraft_TRAPC_Horizontal +http://www.switchcraft.com/ProductSummary.aspx?Parent=620 http://www.switchcraft.com/Drawings/TRAPC_X-TRASM_X_SERIES_CD.PDF +THT Mini XLR 5Pin right angle +0 +5 +5 +Connector_BarrelJack +BarrelJack_CLIFF_FC681465S_SMT_Horizontal +Surface-mount DC Barrel Jack, https://www.cliffuk.co.uk/products/dcconnectors/FC681465S.pdf +Power Jack SMT +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-036AH-SMT_Horizontal +Surface-mount DC Barrel Jack, http://www.cui.com/product/resource/pj-036ah-smt.pdf +Power Jack SMT +0 +3 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-063AH_Horizontal_CircularHoles +Barrel Jack, 2.0mm ID, 5.5mm OD, 24V, 8A, no switch, https://www.cui.com/product/resource/pj-063ah.pdf +barrel jack cui dc power +0 +4 +3 +Connector_BarrelJack +BarrelJack_CUI_PJ-102AH_Horizontal +Thin-pin DC Barrel Jack, https://cdn-shop.adafruit.com/datasheets/21mmdcjackDatasheet.pdf +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_GCT_DCJ200-10-A_Horizontal +Barrel jack connector (5.5 mm outer diameter, 2.05 inner diameter ), https://gct.co/files/drawings/dcj200-10.pdf +connector barrel jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_Horizontal +DC Barrel Jack +Power Jack +0 +3 +3 +Connector_BarrelJack +BarrelJack_SwitchcraftConxall_RAPC10U_Horizontal +DC Power Jack, 13A, 24V, Panel Mount,Through-hole, https://www.switchcraft.com/Drawings/RAPC10U_CD.pdf +barreljack switchcraftconxall dc power +0 +2 +2 +Connector_BarrelJack +BarrelJack_Wuerth_6941xx301002 +Wuerth electronics barrel jack connector (5.5mm outher diameter, inner diameter 2.05mm or 2.55mm depending on exact order number), See: http://katalog.we-online.de/em/datasheet/6941xx301002.pdf +connector barrel jack +0 +3 +3 +Connector_Card +CF-Card_3M_N7E50-A516xx-30 +Compact Flash Card connector, polarization inverse (https://multimedia.3m.com/mws/media/22424O/3mtm-cf-card-header-type-i-low-profile-surface-mount-ts0747.pdf) +connector cf +0 +54 +50 +Connector_Card +CF-Card_3M_N7E50-E516xx-30 +Compact Flash Card connector, normal polarization (https://multimedia.3m.com/mws/media/22424O/3mtm-cf-card-header-type-i-low-profile-surface-mount-ts0747.pdf) +connector cf +0 +54 +50 +Connector_Card +SD_Kyocera_145638009211859+ +SD Card Connector, Normal Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638009511859+ +SD Card Connector, Normal Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109211859+ +SD Card Connector, Reverse Type, Outer Tail, Without Ejector (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_Kyocera_145638109511859+ +SD Card Connector, Reverse Type, Outer Tail, Spring Eject Type (https://global.kyocera.com/prdct/electro/product/pdf/5638.pdf) +sd card smt +0 +13 +13 +Connector_Card +SD_TE_2041021 +SD card connector, top mount, SMT (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F2041021%7FB%7Fpdf%7FEnglish%7FENG_CD_2041021_B_C_2041021_B.pdf%7F2041021-4) +sd card +0 +15 +12 +Connector_Card +microSD_HC_Hirose_DM3AT-SF-PEJM5 +Micro SD, SMD, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3AT-SF-PEJM5/category/Drawing%20(2D)/doc_file_id/44099/?file_category_id=6&item_id=06090031000&is_series=) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Hirose_DM3BT-DSF-PEJS +Micro SD, SMD, reverse on-board, right-angle, push-pull (https://www.hirose.com/product/en/download_file/key_name/DM3BT-DSF-PEJS/category/Drawing%20(2D)/doc_file_id/44097/?file_category_id=6&item_id=06090029900&is_series=) +Micro SD +0 +16 +11 +Connector_Card +microSD_HC_Hirose_DM3D-SF +Micro SD, SMD, right-angle, push-pull (https://media.digikey.com/PDF/Data%20Sheets/Hirose%20PDFs/DM3D-SF.pdf) +Micro SD +0 +14 +11 +Connector_Card +microSD_HC_Molex_104031-0811 +1.10mm Pitch microSD Memory Card Connector, Surface Mount, Push-Pull Type, 1.42mm Height, with Detect Switch (https://www.molex.com/pdm_docs/sd/1040310811_sd.pdf) +microSD SD molex +0 +14 +11 +Connector_Card +microSD_HC_Wuerth_693072010801 +http://katalog.we-online.de/em/datasheet/693072010801.pdf +Micro SD Wuerth Wurth Würth +0 +12 +9 +Connector_Card +microSIM_JAE_SF53S006VCBR2000 +https://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ115712.pdf +microSIM GSM Card +0 +14 +7 +Connector_Coaxial +BNC_Amphenol_031-6575_Horizontal +dual independently isolated BNC plug (https://www.amphenolrf.com/downloads/dl/file/id/2980/product/644/031_6575_customer_drawing.pdf) +Dual BNC Amphenol Horizontal +0 +6 +4 +Connector_Coaxial +BNC_Amphenol_B6252HB-NPP3G-50_Horizontal +http://www.farnell.com/datasheets/612848.pdf +BNC Amphenol Horizontal +0 +4 +2 +Connector_Coaxial +BNC_PanelMountable_Vertical +Panel-mountable BNC connector mounted through PCB, vertical +BNC connector +0 +2 +2 +Connector_Coaxial +BNC_TEConnectivity_1478035_Horizontal +BNC RF Interface, PCB mount 4 pin, Right Angle, Bayonet, 50Ohm, 4GHz, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1478035%7FB1%7Fpdf%7FEnglish%7FENG_CD_1478035_B1.pdf%7F1-1478035-0 +BNC RF interface bayonet 50ohm +0 +5 +2 +Connector_Coaxial +BNC_TEConnectivity_1478204_Vertical +BNC female PCB mount 4 pin straight chassis connector http://www.te.com/usa-en/product-1-1478204-0.html +BNC female PCB mount 4 pin straight chassis connector +0 +5 +2 +Connector_Coaxial +BNC_Win_364A2x95_Horizontal +Dual front isolated BNC plug (https://www.winconn.com/wp-content/uploads/364A2595.pdf) +Dual BNC Horizontal Isolated +0 +6 +3 +Connector_Coaxial +CoaxialSwitch_Hirose_MS-156C3_Horizontal +Subminiature Coaxial Switch 1.35mm High, DC to 11GHz +Switch Coaxial RF +0 +12 +3 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_0.8mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.0mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-0961_Horizontal_1.6mm-PCB +Molex MMCX Horizontal Coaxial https://www.molex.com/pdm_docs/sd/734150961_sd.pdf +Molex MMCX Horizontal Coaxial +0 +3 +2 +Connector_Coaxial +MMCX_Molex_73415-1471_Vertical +http://www.molex.com/pdm_docs/sd/734151471_sd.pdf +Molex MMCX Coaxial Connector 50 ohms Female Jack Vertical THT +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_901-143_Horizontal + Amphenol RF 901-143 https://www.amphenolrf.com/library/download/link/link_id/585682 +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_901-144_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/7023/product/3103/901_144_customer_drawing.pdf +SMA THT Female Jack Vertical +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-10_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/4007/product/2974/132134_10_customer_drawing.pdf +SMA SMD Female Jack Vertical +0 +3 +2 +Connector_Coaxial +SMA_Amphenol_132134-11_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3406/product/2975/132134_11_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-14_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1793/product/2976/132134_14_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134-16_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1141/product/2978/132134_16_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132134_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/2187/product/2843/132134_customer_drawing.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132203-12_Horizontal +https://www.amphenolrf.com/media/downloads/1769/132203-12.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132289_EdgeMount +http://www.amphenolrf.com/132289.html +SMA +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291-12_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/1688/product/3020/132291_12_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Amphenol_132291_Vertical +https://www.amphenolrf.com/downloads/dl/file/id/3222/product/2918/132291_customer_drawing.pdf +SMA THT Female Jack Vertical Bulkhead +0 +5 +2 +Connector_Coaxial +SMA_Molex_73251-1153_EdgeMount_Horizontal +Molex SMA RF Connectors, Edge Mount, (http://www.molex.com/pdm_docs/sd/732511150_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2120_EdgeMount_Horizontal +Molex SMA RF Connector, Edge Mount, (http://www.molex.com/pdm_docs/sd/732512120_sd.pdf) +sma edge +0 +11 +2 +Connector_Coaxial +SMA_Molex_73251-2200_Horizontal +https://www.molex.com/webdocs/datasheets/pdf/en-us/0732512200_RF_COAX_CONNECTORS.pdf +SMA THT Female Jack Horizontal +0 +5 +2 +Connector_Coaxial +SMA_Samtec_SMA-J-P-X-ST-EM1_EdgeMount +Connector SMA, 0Hz to 20GHz, 50Ohm, Edge Mount (http://suddendocs.samtec.com/prints/sma-j-p-x-st-em1-mkt.pdf) +SMA Straight Samtec Edge Mount +0 +5 +2 +Connector_Coaxial +SMA_Wurth_60312002114503_Vertical +https://www.we-online.de/katalog/datasheet/60312002114503.pdf +SMA THT Female Jack Vertical ExtendedLegs +0 +5 +2 +Connector_Coaxial +SMB_Jack_Vertical +SMB pcb mounting jack +SMB Jack Striaght +0 +5 +2 +Connector_Coaxial +U.FL_Hirose_U.FL-R-SMT-1_Vertical +Hirose U.FL Coaxial https://www.hirose.com/product/en/products/U.FL/U.FL-R-SMT-1%2810%29/ +Hirose U.FL Coaxial +0 +3 +2 +Connector_Coaxial +U.FL_Molex_MCRF_73412-0110_Vertical +Molex Microcoaxial RF Connectors (MCRF), mates Hirose U.FL, (http://www.molex.com/pdm_docs/sd/734120110_sd.pdf) +mcrf hirose ufl u.fl microcoaxial +0 +4 +2 +Connector_DIN +DIN41612_B2_2x8_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x8_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +16 +16 +Connector_DIN +DIN41612_B2_2x16_Female_Vertical_THT +DIN41612 connector, type B/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B2_2x16_Male_Horizontal_THT +DIN41612 connector, type B/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/2 +0 +32 +32 +Connector_DIN +DIN41612_B3_2x5_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x5_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +10 +10 +Connector_DIN +DIN41612_B3_2x10_Female_Vertical_THT +DIN41612 connector, type B/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B3_2x10_Male_Horizontal_THT +DIN41612 connector, type B/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B/3 +0 +20 +20 +Connector_DIN +DIN41612_B_1x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_1x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x16_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +32 +32 +Connector_DIN +DIN41612_B_2x32_Female_Vertical_THT +DIN41612 connector, type B, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_B_2x32_Male_Horizontal_THT +DIN41612 connector, type B, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 B +0 +64 +64 +Connector_DIN +DIN41612_C2_2x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_2x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +32 +32 +Connector_DIN +DIN41612_C2_3x16_Female_Vertical_THT +DIN41612 connector, type C/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C2_3x16_Male_Horizontal_THT +DIN41612 connector, type C/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/2 +0 +48 +48 +Connector_DIN +DIN41612_C3_2x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_2x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +20 +20 +Connector_DIN +DIN41612_C3_3x10_Female_Vertical_THT +DIN41612 connector, type C/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C3_3x10_Male_Horizontal_THT +DIN41612 connector, type C/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C/3 +0 +30 +30 +Connector_DIN +DIN41612_C_1x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_1x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +32 +32 +Connector_DIN +DIN41612_C_2x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_2x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +64 +64 +Connector_DIN +DIN41612_C_3x16_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x16_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +48 +48 +Connector_DIN +DIN41612_C_3x32_Female_Vertical_THT +DIN41612 connector, type C, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_C_3x32_Male_Horizontal_THT +DIN41612 connector, type C, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 C +0 +96 +96 +Connector_DIN +DIN41612_D_2x8_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x8_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +16 +16 +Connector_DIN +DIN41612_D_2x16_Female_Vertical_THT +DIN41612 connector, type D, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_D_2x16_Male_Horizontal_THT +DIN41612 connector, type D, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 D +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_2x16_RowsAC_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +32 +32 +Connector_DIN +DIN41612_E_3x16_Female_Vertical_THT +DIN41612 connector, type E, Vertical, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_E_3x16_Male_Horizontal_THT +DIN41612 connector, type E, Horizontal, 5 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 E +0 +48 +48 +Connector_DIN +DIN41612_F_2x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_2x16_RowsZD_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +32 +32 +Connector_DIN +DIN41612_F_3x16_Female_Vertical_THT +DIN41612 connector, type F, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_F_3x16_Male_Horizontal_THT +DIN41612 connector, type F, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 F +0 +48 +48 +Connector_DIN +DIN41612_Q2_2x16_Male_Horizontal_THT +DIN41612 connector, type Q/2, Horizontal, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q2_2x16_Male_Vertical_THT +DIN41612 connector, type Q/2, Vertical, 2 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/2 +0 +32 +32 +Connector_DIN +DIN41612_Q3_2x10_Male_Horizontal_THT +DIN41612 connector, type Q/3, Horizontal, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q3_2x10_Male_Vertical_THT +DIN41612 connector, type Q/3, Vertical, 2 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q/3 +0 +20 +20 +Connector_DIN +DIN41612_Q_2x32_Male_Horizontal_THT +DIN41612 connector, type Q, Horizontal, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_Q_2x32_Male_Vertical_THT +DIN41612 connector, type Q, Vertical, 2 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 Q +0 +64 +64 +Connector_DIN +DIN41612_R2_2x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_2x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +32 +32 +Connector_DIN +DIN41612_R2_3x16_Male_Horizontal_THT +DIN41612 connector, type R/2, Horizontal, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R2_3x16_Male_Vertical_THT +DIN41612 connector, type R/2, Vertical, 3 rows 16 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/2 +0 +48 +48 +Connector_DIN +DIN41612_R3_2x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_2x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +20 +20 +Connector_DIN +DIN41612_R3_3x10_Male_Horizontal_THT +DIN41612 connector, type R/3, Horizontal, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R3_3x10_Male_Vertical_THT +DIN41612 connector, type R/3, Vertical, 3 rows 10 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R/3 +0 +30 +30 +Connector_DIN +DIN41612_R_1x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_1x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +32 +32 +Connector_DIN +DIN41612_R_2x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_2x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +64 +64 +Connector_DIN +DIN41612_R_3x16_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x16_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +48 +48 +Connector_DIN +DIN41612_R_3x32_Male_Horizontal_THT +DIN41612 connector, type R, Horizontal, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_DIN +DIN41612_R_3x32_Male_Vertical_THT +DIN41612 connector, type R, Vertical, 3 rows 32 pins wide, https://www.erni-x-press.com/de/downloads/kataloge/englische_kataloge/erni-din41612-iec60603-2-e.pdf +DIN 41612 IEC 60603 R +0 +96 +96 +Connector_Dsub +DSUB-9_Female_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Female_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_EdgeMount_P2.77mm +9-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +9-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +11 +10 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +9 +9 +Connector_Dsub +DSUB-9_Male_Vertical_P2.77x2.84mm_MountingHoles +9-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +9-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 25mm +0 +11 +10 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 25mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 25mm mounting-hole-offset 25mm +0 +17 +16 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 25mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 25mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Female_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_EdgeMount_P2.77mm +15-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +15-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +15 +15 +Connector_Dsub +DSUB-15_Male_Vertical_P2.77x2.84mm_MountingHoles +15-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +15-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 33.3mm +0 +17 +16 +Connector_Dsub +DSUB-25_Female_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Female_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_EdgeMount_P2.77mm +25-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +25-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +25 +25 +Connector_Dsub +DSUB-25_Male_Vertical_P2.77x2.84mm_MountingHoles +25-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +25-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 47.1mm +0 +27 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 33.3mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 33.3mm mounting-hole-offset 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +26-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +26-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +26 +26 +Connector_Dsub +DSUB-26-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +26-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 33.3mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +26-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 33.3mm +0 +28 +27 +Connector_Dsub +DSUB-37_Female_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, female, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup female x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT female pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Female_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT female pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_EdgeMount_P2.77mm +37-pin D-Sub connector, solder-cups edge-mounted, male, x-pin-pitch 2.77mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector edge mount solder cup male x-pin-pitch 2.77mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.54mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.54mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset4.94mm_Housed_MountingHolesOffset7.48mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 4.9399999999999995mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 7.4799999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 4.9399999999999995mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset7.70mm_Housed_MountingHolesOffset9.12mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 7.699999999999999mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 9.12mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 7.699999999999999mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.40mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.4mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset9.90mm_Housed_MountingHolesOffset11.32mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 9.9mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 11.32mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 9.9mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset8.20mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 8.2mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Horizontal_P2.77x2.84mm_EdgePinOffset14.56mm_Housed_MountingHolesOffset15.98mm +37-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.77x2.84mm, pin-PCB-offset 14.56mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 15.979999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector horizontal angled 90deg THT male pitch 2.77x2.84mm pin-PCB-offset 14.56mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +37 +37 +Connector_Dsub +DSUB-37_Male_Vertical_P2.77x2.84mm_MountingHoles +37-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.77x2.84mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +37-pin D-Sub connector straight vertical THT male pitch 2.77x2.84mm mounting holes distance 63.5mm +0 +39 +38 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT female pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Female_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT female pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 47.1mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 47.1mm mounting-hole-offset 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x1.98mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x1.98mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Horizontal_P2.29x2.54mm_EdgePinOffset9.40mm +44-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.29x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +44-pin D-Sub connector horizontal angled 90deg THT male pitch 2.29x2.54mm pin-PCB-offset 9.4mm +0 +44 +44 +Connector_Dsub +DSUB-44-HD_Male_Vertical_P2.29x1.98mm_MountingHoles +44-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.29x1.98mm, distance of mounting holes 47.1mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +44-pin D-Sub connector straight vertical THT male pitch 2.29x1.98mm mounting holes distance 47.1mm +0 +46 +45 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, female, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT female pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Female_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, female, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT female pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset3.03mm_Housed_MountingHolesOffset4.94mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 3.0300000000000002mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 4.9399999999999995mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 3.0300000000000002mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset8.35mm_Housed_MountingHolesOffset10.89mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 8.35mm, distance of mounting holes 63.5mm, distance of mounting holes to PCB edge 10.889999999999999mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 8.35mm mounting-holes-distance 63.5mm mounting-hole-offset 63.5mm +0 +64 +63 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x1.98mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x1.98mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x1.98mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Horizontal_P2.41x2.54mm_EdgePinOffset9.40mm +62-pin D-Sub connector, horizontal/angled (90 deg), THT-mount, male, pitch 2.41x2.54mm, pin-PCB-offset 9.4mm, see http://docs-europe.electrocomponents.com/webdocs/1585/0900766b81585df2.pdf +62-pin D-Sub connector horizontal angled 90deg THT male pitch 2.41x2.54mm pin-PCB-offset 9.4mm +0 +62 +62 +Connector_Dsub +DSUB-62-HD_Male_Vertical_P2.41x1.98mm_MountingHoles +62-pin D-Sub connector, straight/vertical, THT-mount, male, pitch 2.41x1.98mm, distance of mounting holes 63.5mm, see https://disti-assets.s3.amazonaws.com/tonar/files/datasheets/16730.pdf +62-pin D-Sub connector straight vertical THT male pitch 2.41x1.98mm mounting holes distance 63.5mm +0 +64 +63 +Connector_FFC-FPC +Hirose_FH12-6S-0.5SH_1x06-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-6S-0.5SH, 6 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +8 +7 +Connector_FFC-FPC +Hirose_FH12-8S-0.5SH_1x08-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-8S-0.5SH, 8 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +10 +9 +Connector_FFC-FPC +Hirose_FH12-10S-0.5SH_1x10-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-10S-0.5SH, 10 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +12 +11 +Connector_FFC-FPC +Hirose_FH12-11S-0.5SH_1x11-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-11S-0.5SH, 11 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +13 +12 +Connector_FFC-FPC +Hirose_FH12-12S-0.5SH_1x12-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-12S-0.5SH, 12 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +14 +13 +Connector_FFC-FPC +Hirose_FH12-13S-0.5SH_1x13-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-13S-0.5SH, 13 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +15 +14 +Connector_FFC-FPC +Hirose_FH12-14S-0.5SH_1x14-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-14S-0.5SH, 14 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +16 +15 +Connector_FFC-FPC +Hirose_FH12-15S-0.5SH_1x15-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-15S-0.5SH, 15 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +17 +16 +Connector_FFC-FPC +Hirose_FH12-16S-0.5SH_1x16-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-16S-0.5SH, 16 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +18 +17 +Connector_FFC-FPC +Hirose_FH12-17S-0.5SH_1x17-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-17S-0.5SH, 17 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +19 +18 +Connector_FFC-FPC +Hirose_FH12-18S-0.5SH_1x18-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-18S-0.5SH, 18 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +20 +19 +Connector_FFC-FPC +Hirose_FH12-19S-0.5SH_1x19-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-19S-0.5SH, 19 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +21 +20 +Connector_FFC-FPC +Hirose_FH12-20S-0.5SH_1x20-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-20S-0.5SH, 20 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +22 +21 +Connector_FFC-FPC +Hirose_FH12-22S-0.5SH_1x22-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-22S-0.5SH, 22 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +24 +23 +Connector_FFC-FPC +Hirose_FH12-24S-0.5SH_1x24-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-24S-0.5SH, 24 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +26 +25 +Connector_FFC-FPC +Hirose_FH12-25S-0.5SH_1x25-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-25S-0.5SH, 25 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +27 +26 +Connector_FFC-FPC +Hirose_FH12-26S-0.5SH_1x26-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-26S-0.5SH, 26 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +28 +27 +Connector_FFC-FPC +Hirose_FH12-28S-0.5SH_1x28-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-28S-0.5SH, 28 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +30 +29 +Connector_FFC-FPC +Hirose_FH12-30S-0.5SH_1x30-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-30S-0.5SH, 30 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +32 +31 +Connector_FFC-FPC +Hirose_FH12-32S-0.5SH_1x32-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-32S-0.5SH, 32 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +34 +33 +Connector_FFC-FPC +Hirose_FH12-33S-0.5SH_1x33-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-33S-0.5SH, 33 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +35 +34 +Connector_FFC-FPC +Hirose_FH12-34S-0.5SH_1x34-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-34S-0.5SH, 34 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +36 +35 +Connector_FFC-FPC +Hirose_FH12-35S-0.5SH_1x35-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-35S-0.5SH, 35 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +37 +36 +Connector_FFC-FPC +Hirose_FH12-36S-0.5SH_1x36-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-36S-0.5SH, 36 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +38 +37 +Connector_FFC-FPC +Hirose_FH12-40S-0.5SH_1x40-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-40S-0.5SH, 40 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +42 +41 +Connector_FFC-FPC +Hirose_FH12-45S-0.5SH_1x45-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-45S-0.5SH, 45 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +47 +46 +Connector_FFC-FPC +Hirose_FH12-50S-0.5SH_1x50-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-50S-0.5SH, 50 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +52 +51 +Connector_FFC-FPC +Hirose_FH12-53S-0.5SH_1x53-1MP_P0.50mm_Horizontal +Hirose FH12, FFC/FPC connector, FH12-53S-0.5SH, 53 Pins per row (https://www.hirose.com/product/en/products/FH12/FH12-24S-0.5SH(55)/), generated with kicad-footprint-generator +connector Hirose FH12 horizontal +0 +55 +54 +Connector_FFC-FPC +Hirose_FH41-30S-0.5SH_1x30_1MP_1SH_P0.5mm_Horizontal +Hirose FH41, FFC/FPC connector, FH41-30S-0.5SH, 30 Pins per row (https://www.hirose.com/fr/product/document?clcode=CL0580-2218-5-05&productname=FH41-30S-0.5SH(05)&series=FH41&documenttype=2DDrawing&lang=fr&documentid=0001001704) +connector Hirose FH41 horizontal +0 +38 +32 +Connector_FFC-FPC +JAE_FF0825SA1_2Rows-25Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0825SA1, 25 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +25 +25 +Connector_FFC-FPC +JAE_FF0829SA1_2Rows-29Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0829SA1, 29 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +29 +29 +Connector_FFC-FPC +JAE_FF0841SA1_2Rows-41Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0841SA1, 41 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +41 +41 +Connector_FFC-FPC +JAE_FF0851SA1_2Rows-51Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0851SA1, 51 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +51 +51 +Connector_FFC-FPC +JAE_FF0871SA1_2Rows-71Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0871SA1, 71 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +71 +71 +Connector_FFC-FPC +JAE_FF0881SA1_2Rows-81Pins_P0.40mm_Horizontal +Molex JAE 0.2mm pitch, 1mm overall height FFC/FPC connector, FF0881SA1, 81 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ108178.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +81 +81 +Connector_FFC-FPC +Molex_52559-3652_2x18-1MP_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC, 52559-3652, 36 Circuits (https://www.molex.com/pdm_docs/sd/525593652_sd.pdf) +connector Molex top entry +0 +40 +37 +Connector_FFC-FPC +Molex_54132-5033_1x50-1MP_P0.5mm_Horizontal +Molex FFC/FPC connector, 50 bottom-side contacts, 0.5mm pitch, 2.0mm height, https://www.molex.com/pdm_docs/sd/541325033_sd.pdf +FFC FPC +0 +54 +51 +Connector_FFC-FPC +Molex_54548-1071_1x10-1MP_P0.5mm_Horizontal +Molex FFC/FPC connector, 10 bottom-side contacts, 0.5mm pitch, 1.2mm height, https://www.molex.com/pdm_docs/sd/545481071_sd.pdf +FFC FPC connector +0 +12 +11 +Connector_FFC-FPC +Molex_200528-0040_1x04-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0040, 4 Circuits (https://www.molex.com/pdm_docs/sd/2005280040_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +6 +5 +Connector_FFC-FPC +Molex_200528-0050_1x05-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0050, 5 Circuits (https://www.molex.com/pdm_docs/sd/2005280050_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +7 +6 +Connector_FFC-FPC +Molex_200528-0060_1x06-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0060, 6 Circuits (https://www.molex.com/pdm_docs/sd/2005280060_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +8 +7 +Connector_FFC-FPC +Molex_200528-0070_1x07-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0070, 7 Circuits (https://www.molex.com/pdm_docs/sd/2005280070_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +9 +8 +Connector_FFC-FPC +Molex_200528-0080_1x08-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0080, 8 Circuits (https://www.molex.com/pdm_docs/sd/2005280080_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +10 +9 +Connector_FFC-FPC +Molex_200528-0090_1x09-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0090, 9 Circuits (https://www.molex.com/pdm_docs/sd/2005280090_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +11 +10 +Connector_FFC-FPC +Molex_200528-0100_1x10-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0100, 10 Circuits (https://www.molex.com/pdm_docs/sd/2005280100_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +12 +11 +Connector_FFC-FPC +Molex_200528-0110_1x11-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0110, 11 Circuits (https://www.molex.com/pdm_docs/sd/2005280110_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +13 +12 +Connector_FFC-FPC +Molex_200528-0120_1x12-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0120, 12 Circuits (https://www.molex.com/pdm_docs/sd/2005280120_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +14 +13 +Connector_FFC-FPC +Molex_200528-0130_1x13-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0130, 13 Circuits (https://www.molex.com/pdm_docs/sd/2005280130_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +15 +14 +Connector_FFC-FPC +Molex_200528-0140_1x14-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0140, 14 Circuits (https://www.molex.com/pdm_docs/sd/2005280140_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +16 +15 +Connector_FFC-FPC +Molex_200528-0150_1x15-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0150, 15 Circuits (https://www.molex.com/pdm_docs/sd/2005280150_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +17 +16 +Connector_FFC-FPC +Molex_200528-0160_1x16-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0160, 16 Circuits (https://www.molex.com/pdm_docs/sd/2005280160_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +18 +17 +Connector_FFC-FPC +Molex_200528-0170_1x17-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0170, 17 Circuits (https://www.molex.com/pdm_docs/sd/2005280170_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_200528-0180_1x18-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0180, 18 Circuits (https://www.molex.com/pdm_docs/sd/2005280180_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +20 +19 +Connector_FFC-FPC +Molex_200528-0190_1x19-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0190, 19 Circuits (https://www.molex.com/pdm_docs/sd/2005280190_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +21 +20 +Connector_FFC-FPC +Molex_200528-0200_1x20-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0200, 20 Circuits (https://www.molex.com/pdm_docs/sd/2005280200_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +22 +21 +Connector_FFC-FPC +Molex_200528-0210_1x21-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0210, 21 Circuits (https://www.molex.com/pdm_docs/sd/2005280210_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_200528-0220_1x22-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0220, 22 Circuits (https://www.molex.com/pdm_docs/sd/2005280220_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +24 +23 +Connector_FFC-FPC +Molex_200528-0230_1x23-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0230, 23 Circuits (https://www.molex.com/pdm_docs/sd/2005280230_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_200528-0240_1x24-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0240, 24 Circuits (https://www.molex.com/pdm_docs/sd/2005280240_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +26 +25 +Connector_FFC-FPC +Molex_200528-0250_1x25-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0250, 25 Circuits (https://www.molex.com/pdm_docs/sd/2005280250_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +27 +26 +Connector_FFC-FPC +Molex_200528-0260_1x26-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0260, 26 Circuits (https://www.molex.com/pdm_docs/sd/2005280260_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +28 +27 +Connector_FFC-FPC +Molex_200528-0270_1x27-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0270, 27 Circuits (https://www.molex.com/pdm_docs/sd/2005280270_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_200528-0280_1x28-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0280, 28 Circuits (https://www.molex.com/pdm_docs/sd/2005280280_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +30 +29 +Connector_FFC-FPC +Molex_200528-0290_1x29-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0290, 29 Circuits (https://www.molex.com/pdm_docs/sd/2005280290_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +31 +30 +Connector_FFC-FPC +Molex_200528-0300_1x30-1MP_P1.00mm_Horizontal +Molex Molex 1.00mm Pitch Easy-On BackFlip, Right-Angle, Bottom Contact FFC/FPC, 200528-0300, 30 Circuits (https://www.molex.com/pdm_docs/sd/2005280300_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +32 +31 +Connector_FFC-FPC +Molex_502231-1500_1x15-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 15 Circuits (https://www.molex.com/pdm_docs/sd/5022311500_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +17 +16 +Connector_FFC-FPC +Molex_502231-2400_1x24-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 24 Circuits (https://www.molex.com/pdm_docs/sd/5022312400_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +26 +25 +Connector_FFC-FPC +Molex_502231-3300_1x33-1SH_P0.5mm_Vertical +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 6.05mm Height, Vertical, Surface Mount, ZIF, 33 Circuits (https://www.molex.com/pdm_docs/sd/5022313300_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm vertical +0 +36 +34 +Connector_FFC-FPC +Molex_502244-1530_1x15-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 15 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +19 +16 +Connector_FFC-FPC +Molex_502244-2430_1x24-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 24 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +28 +25 +Connector_FFC-FPC +Molex_502244-3330_1x33-1MP_P0.5mm_Horizontal +Molex 0.50mm Pitch Easy-On Type FFC/FPC Connector, For LVDS, 2.33mm Height, Right Angle, Surface Mount, ZIF, Bottom Contact Style, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022441530_sd.pdf) +molex FFC/FPC connector Pitch 0.5mm right angle +0 +39 +34 +Connector_FFC-FPC +Molex_502250-1791_2Rows-17Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-1791, 17 Circuits (http://www.molex.com/pdm_docs/sd/5022501791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +19 +18 +Connector_FFC-FPC +Molex_502250-2191_2Rows-21Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2191, 21 Circuits (http://www.molex.com/pdm_docs/sd/5022502191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +23 +22 +Connector_FFC-FPC +Molex_502250-2391_2Rows-23Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2391, 23 Circuits (http://www.molex.com/pdm_docs/sd/5022502391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +25 +24 +Connector_FFC-FPC +Molex_502250-2791_2Rows-27Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-2791, 27 Circuits (http://www.molex.com/pdm_docs/sd/5022502791_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +29 +28 +Connector_FFC-FPC +Molex_502250-3391_2Rows-33Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3391, 33 Circuits (http://www.molex.com/pdm_docs/sd/5022503391_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +35 +34 +Connector_FFC-FPC +Molex_502250-3591_2Rows-35Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3591, 35 Circuits (http://www.molex.com/pdm_docs/sd/5022503591_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +37 +36 +Connector_FFC-FPC +Molex_502250-3991_2Rows-39Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-3991, 39 Circuits (http://www.molex.com/pdm_docs/sd/5022503991_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +41 +40 +Connector_FFC-FPC +Molex_502250-4191_2Rows-41Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-4191, 41 Circuits (http://www.molex.com/pdm_docs/sd/5022504191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +43 +42 +Connector_FFC-FPC +Molex_502250-5191_2Rows-51Pins-1MP_P0.60mm_Horizontal +Molex Molex 0.30mm Pitch Easy-On BackFlip Type FFC/FPC, 502250-5191, 51 Circuits (http://www.molex.com/pdm_docs/sd/5022505191_sd.pdf), generated with kicad-footprint-generator +connector Molex top entry +0 +53 +52 +Connector_FFC-FPC +TE_0-1734839-5_1x05-1MP_P0.5mm_Horizontal +TE FPC connector, 05 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +7 +6 +Connector_FFC-FPC +TE_0-1734839-6_1x06-1MP_P0.5mm_Horizontal +TE FPC connector, 06 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +8 +7 +Connector_FFC-FPC +TE_0-1734839-7_1x07-1MP_P0.5mm_Horizontal +TE FPC connector, 07 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +9 +8 +Connector_FFC-FPC +TE_0-1734839-8_1x08-1MP_P0.5mm_Horizontal +TE FPC connector, 08 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +10 +9 +Connector_FFC-FPC +TE_0-1734839-9_1x09-1MP_P0.5mm_Horizontal +TE FPC connector, 09 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +11 +10 +Connector_FFC-FPC +TE_1-84952-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +12 +11 +Connector_FFC-FPC +TE_1-84952-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +13 +12 +Connector_FFC-FPC +TE_1-84952-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +14 +13 +Connector_FFC-FPC +TE_1-84952-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +15 +14 +Connector_FFC-FPC +TE_1-84952-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +16 +15 +Connector_FFC-FPC +TE_1-84952-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +17 +16 +Connector_FFC-FPC +TE_1-84952-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +18 +17 +Connector_FFC-FPC +TE_1-84952-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +19 +18 +Connector_FFC-FPC +TE_1-84952-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +20 +19 +Connector_FFC-FPC +TE_1-84952-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +21 +20 +Connector_FFC-FPC +TE_1-84953-0_1x10-1MP_P1.0mm_Horizontal +TE FPC connector, 10 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +12 +11 +Connector_FFC-FPC +TE_1-84953-1_1x11-1MP_P1.0mm_Horizontal +TE FPC connector, 11 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +13 +12 +Connector_FFC-FPC +TE_1-84953-2_1x12-1MP_P1.0mm_Horizontal +TE FPC connector, 12 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +14 +13 +Connector_FFC-FPC +TE_1-84953-3_1x13-1MP_P1.0mm_Horizontal +TE FPC connector, 13 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +15 +14 +Connector_FFC-FPC +TE_1-84953-4_1x14-1MP_P1.0mm_Horizontal +TE FPC connector, 14 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +16 +15 +Connector_FFC-FPC +TE_1-84953-5_1x15-1MP_P1.0mm_Horizontal +TE FPC connector, 15 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +17 +16 +Connector_FFC-FPC +TE_1-84953-6_1x16-1MP_P1.0mm_Horizontal +TE FPC connector, 16 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +18 +17 +Connector_FFC-FPC +TE_1-84953-7_1x17-1MP_P1.0mm_Horizontal +TE FPC connector, 17 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +19 +18 +Connector_FFC-FPC +TE_1-84953-8_1x18-1MP_P1.0mm_Horizontal +TE FPC connector, 18 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +20 +19 +Connector_FFC-FPC +TE_1-84953-9_1x19-1MP_P1.0mm_Horizontal +TE FPC connector, 19 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +21 +20 +Connector_FFC-FPC +TE_1-1734839-0_1x10-1MP_P0.5mm_Horizontal +TE FPC connector, 10 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +12 +11 +Connector_FFC-FPC +TE_1-1734839-1_1x11-1MP_P0.5mm_Horizontal +TE FPC connector, 11 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +13 +12 +Connector_FFC-FPC +TE_1-1734839-2_1x12-1MP_P0.5mm_Horizontal +TE FPC connector, 12 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +14 +13 +Connector_FFC-FPC +TE_1-1734839-3_1x13-1MP_P0.5mm_Horizontal +TE FPC connector, 13 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +15 +14 +Connector_FFC-FPC +TE_1-1734839-4_1x14-1MP_P0.5mm_Horizontal +TE FPC connector, 14 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +16 +15 +Connector_FFC-FPC +TE_1-1734839-5_1x15-1MP_P0.5mm_Horizontal +TE FPC connector, 15 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +17 +16 +Connector_FFC-FPC +TE_1-1734839-6_1x16-1MP_P0.5mm_Horizontal +TE FPC connector, 16 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +18 +17 +Connector_FFC-FPC +TE_1-1734839-7_1x17-1MP_P0.5mm_Horizontal +TE FPC connector, 17 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +19 +18 +Connector_FFC-FPC +TE_1-1734839-8_1x18-1MP_P0.5mm_Horizontal +TE FPC connector, 18 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +20 +19 +Connector_FFC-FPC +TE_1-1734839-9_1x19-1MP_P0.5mm_Horizontal +TE FPC connector, 19 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +21 +20 +Connector_FFC-FPC +TE_2-84952-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +22 +21 +Connector_FFC-FPC +TE_2-84952-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +23 +22 +Connector_FFC-FPC +TE_2-84952-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +24 +23 +Connector_FFC-FPC +TE_2-84952-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +25 +24 +Connector_FFC-FPC +TE_2-84952-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +26 +25 +Connector_FFC-FPC +TE_2-84952-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +27 +26 +Connector_FFC-FPC +TE_2-84952-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +28 +27 +Connector_FFC-FPC +TE_2-84952-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +29 +28 +Connector_FFC-FPC +TE_2-84952-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +30 +29 +Connector_FFC-FPC +TE_2-84952-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +31 +30 +Connector_FFC-FPC +TE_2-84953-0_1x20-1MP_P1.0mm_Horizontal +TE FPC connector, 20 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +22 +21 +Connector_FFC-FPC +TE_2-84953-1_1x21-1MP_P1.0mm_Horizontal +TE FPC connector, 21 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +23 +22 +Connector_FFC-FPC +TE_2-84953-2_1x22-1MP_P1.0mm_Horizontal +TE FPC connector, 22 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +24 +23 +Connector_FFC-FPC +TE_2-84953-3_1x23-1MP_P1.0mm_Horizontal +TE FPC connector, 23 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +25 +24 +Connector_FFC-FPC +TE_2-84953-4_1x24-1MP_P1.0mm_Horizontal +TE FPC connector, 24 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +26 +25 +Connector_FFC-FPC +TE_2-84953-5_1x25-1MP_P1.0mm_Horizontal +TE FPC connector, 25 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +27 +26 +Connector_FFC-FPC +TE_2-84953-6_1x26-1MP_P1.0mm_Horizontal +TE FPC connector, 26 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +28 +27 +Connector_FFC-FPC +TE_2-84953-7_1x27-1MP_P1.0mm_Horizontal +TE FPC connector, 27 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +29 +28 +Connector_FFC-FPC +TE_2-84953-8_1x28-1MP_P1.0mm_Horizontal +TE FPC connector, 28 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +30 +29 +Connector_FFC-FPC +TE_2-84953-9_1x29-1MP_P1.0mm_Horizontal +TE FPC connector, 29 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +31 +30 +Connector_FFC-FPC +TE_2-1734839-0_1x20-1MP_P0.5mm_Horizontal +TE FPC connector, 20 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +22 +21 +Connector_FFC-FPC +TE_2-1734839-1_1x21-1MP_P0.5mm_Horizontal +TE FPC connector, 21 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +23 +22 +Connector_FFC-FPC +TE_2-1734839-2_1x22-1MP_P0.5mm_Horizontal +TE FPC connector, 22 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +24 +23 +Connector_FFC-FPC +TE_2-1734839-3_1x23-1MP_P0.5mm_Horizontal +TE FPC connector, 23 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +25 +24 +Connector_FFC-FPC +TE_2-1734839-4_1x24-1MP_P0.5mm_Horizontal +TE FPC connector, 24 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +26 +25 +Connector_FFC-FPC +TE_2-1734839-5_1x25-1MP_P0.5mm_Horizontal +TE FPC connector, 25 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +27 +26 +Connector_FFC-FPC +TE_2-1734839-6_1x26-1MP_P0.5mm_Horizontal +TE FPC connector, 26 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +28 +27 +Connector_FFC-FPC +TE_2-1734839-7_1x27-1MP_P0.5mm_Horizontal +TE FPC connector, 27 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +29 +28 +Connector_FFC-FPC +TE_2-1734839-8_1x28-1MP_P0.5mm_Horizontal +TE FPC connector, 28 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +30 +29 +Connector_FFC-FPC +TE_2-1734839-9_1x29-1MP_P0.5mm_Horizontal +TE FPC connector, 29 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +31 +30 +Connector_FFC-FPC +TE_3-84952-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +32 +31 +Connector_FFC-FPC +TE_3-84953-0_1x30-1MP_P1.0mm_Horizontal +TE FPC connector, 30 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-0_1x30-1MP_P0.5mm_Horizontal +TE FPC connector, 30 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +32 +31 +Connector_FFC-FPC +TE_3-1734839-1_1x31-1MP_P0.5mm_Horizontal +TE FPC connector, 31 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +33 +32 +Connector_FFC-FPC +TE_3-1734839-2_1x32-1MP_P0.5mm_Horizontal +TE FPC connector, 32 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +34 +33 +Connector_FFC-FPC +TE_3-1734839-3_1x33-1MP_P0.5mm_Horizontal +TE FPC connector, 33 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +35 +34 +Connector_FFC-FPC +TE_3-1734839-4_1x34-1MP_P0.5mm_Horizontal +TE FPC connector, 34 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +36 +35 +Connector_FFC-FPC +TE_3-1734839-5_1x35-1MP_P0.5mm_Horizontal +TE FPC connector, 35 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +37 +36 +Connector_FFC-FPC +TE_3-1734839-6_1x36-1MP_P0.5mm_Horizontal +TE FPC connector, 36 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +38 +37 +Connector_FFC-FPC +TE_3-1734839-7_1x37-1MP_P0.5mm_Horizontal +TE FPC connector, 37 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +39 +38 +Connector_FFC-FPC +TE_3-1734839-8_1x38-1MP_P0.5mm_Horizontal +TE FPC connector, 38 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +40 +39 +Connector_FFC-FPC +TE_3-1734839-9_1x39-1MP_P0.5mm_Horizontal +TE FPC connector, 39 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +41 +40 +Connector_FFC-FPC +TE_4-1734839-0_1x40-1MP_P0.5mm_Horizontal +TE FPC connector, 40 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +42 +41 +Connector_FFC-FPC +TE_4-1734839-1_1x41-1MP_P0.5mm_Horizontal +TE FPC connector, 41 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +43 +42 +Connector_FFC-FPC +TE_4-1734839-2_1x42-1MP_P0.5mm_Horizontal +TE FPC connector, 42 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +44 +43 +Connector_FFC-FPC +TE_4-1734839-3_1x43-1MP_P0.5mm_Horizontal +TE FPC connector, 43 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +45 +44 +Connector_FFC-FPC +TE_4-1734839-4_1x44-1MP_P0.5mm_Horizontal +TE FPC connector, 44 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +46 +45 +Connector_FFC-FPC +TE_4-1734839-5_1x45-1MP_P0.5mm_Horizontal +TE FPC connector, 45 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +47 +46 +Connector_FFC-FPC +TE_4-1734839-6_1x46-1MP_P0.5mm_Horizontal +TE FPC connector, 46 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +48 +47 +Connector_FFC-FPC +TE_4-1734839-7_1x47-1MP_P0.5mm_Horizontal +TE FPC connector, 47 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +49 +48 +Connector_FFC-FPC +TE_4-1734839-8_1x48-1MP_P0.5mm_Horizontal +TE FPC connector, 48 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +50 +49 +Connector_FFC-FPC +TE_4-1734839-9_1x49-1MP_P0.5mm_Horizontal +TE FPC connector, 49 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +51 +50 +Connector_FFC-FPC +TE_5-1734839-0_1x50-1MP_P0.5mm_Horizontal +TE FPC connector, 50 top-side contacts, 0.5mm pitch, SMT, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Customer+Drawing%7F1734839%7FC%7Fpdf%7FEnglish%7FENG_CD_1734839_C_C_1734839.pdf%7F4-1734839-0 +te fpc 1734839 +0 +52 +51 +Connector_FFC-FPC +TE_84952-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +6 +5 +Connector_FFC-FPC +TE_84952-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +7 +6 +Connector_FFC-FPC +TE_84952-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +8 +7 +Connector_FFC-FPC +TE_84952-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +9 +8 +Connector_FFC-FPC +TE_84952-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +10 +9 +Connector_FFC-FPC +TE_84952-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 bottom-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84952&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84952-4 +te fpc 84952 +0 +11 +10 +Connector_FFC-FPC +TE_84953-4_1x04-1MP_P1.0mm_Horizontal +TE FPC connector, 04 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +6 +5 +Connector_FFC-FPC +TE_84953-5_1x05-1MP_P1.0mm_Horizontal +TE FPC connector, 05 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +7 +6 +Connector_FFC-FPC +TE_84953-6_1x06-1MP_P1.0mm_Horizontal +TE FPC connector, 06 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +8 +7 +Connector_FFC-FPC +TE_84953-7_1x07-1MP_P1.0mm_Horizontal +TE FPC connector, 07 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +9 +8 +Connector_FFC-FPC +TE_84953-8_1x08-1MP_P1.0mm_Horizontal +TE FPC connector, 08 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +10 +9 +Connector_FFC-FPC +TE_84953-9_1x09-1MP_P1.0mm_Horizontal +TE FPC connector, 09 top-side contacts, 1.0mm pitch, 1.0mm height, SMT, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=84953&DocType=Customer+Drawing&DocLang=English&DocFormat=pdf&PartCntxt=84953-4 +te fpc 84953 +0 +11 +10 +Connector_FFC-FPC +Wuerth_68611214422_1x12-1MP_P1.0mm_Horizontal +http://katalog.we-online.de/em/datasheet/68611214422.pdf +Wuerth FPC 68611214422 connector 12 bottom-side contacts 1.0mm pitch 1.0mm height SMT +0 +14 +13 +Connector_HDMI +HDMI_A_Contact_Technology_HDMI-19APL2_Horizontal +HDMI Contact Technology Type A http://www.contactswitch.com/en/download.aspx?id=1449 +HDMI Contact Technology Type A +0 +23 +20 +Connector_HDMI +HDMI_A_Kycon_KDMIX-SL1-NS-WS-B15_VerticalRightAngle +HDMI, Type A, Kycon KDMIX-SL1-NS-WS-B15, Vertical Right Angle, http://www.kycon.com/Pub_Eng_Draw/KDMIX-SL1-NS-WS-B15.pdf +hdmi type a +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-0x01 +HDMI, Micro, Type D, SMD, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle smd +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-1x01 +HDMI, Micro, Type D, THT, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht +0 +23 +20 +Connector_HDMI +HDMI_Micro-D_Molex_46765-2x0x +HDMI, Micro, Type D, THT/SMD hybrid, 0.4mm pitch, 19 ckt, right angle (http://www.molex.com/pdm_docs/sd/467651301_sd.pdf) +hdmi micro type d right angle tht smd hybrid +0 +23 +20 +Connector_Harting +Harting_har-flexicon_14110213001xxx_1x02-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110213001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +4 +3 +Connector_Harting +Harting_har-flexicon_14110213002xxx_1x02-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110213002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +4 +3 +Connector_Harting +Harting_har-flexicon_14110213010xxx_1x02-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110213010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +4 +3 +Connector_Harting +Harting_har-flexicon_14110313001xxx_1x03-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110313001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +5 +4 +Connector_Harting +Harting_har-flexicon_14110313002xxx_1x03-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110313002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +5 +4 +Connector_Harting +Harting_har-flexicon_14110313010xxx_1x03-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110313010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +5 +4 +Connector_Harting +Harting_har-flexicon_14110413001xxx_1x04-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110413001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +6 +5 +Connector_Harting +Harting_har-flexicon_14110413002xxx_1x04-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110413002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +6 +5 +Connector_Harting +Harting_har-flexicon_14110413010xxx_1x04-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110413010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +6 +5 +Connector_Harting +Harting_har-flexicon_14110513001xxx_1x05-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110513001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +7 +6 +Connector_Harting +Harting_har-flexicon_14110513002xxx_1x05-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110513002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +7 +6 +Connector_Harting +Harting_har-flexicon_14110513010xxx_1x05-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110513010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +7 +6 +Connector_Harting +Harting_har-flexicon_14110613001xxx_1x06-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110613001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +8 +7 +Connector_Harting +Harting_har-flexicon_14110613002xxx_1x06-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110613002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +8 +7 +Connector_Harting +Harting_har-flexicon_14110613010xxx_1x06-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110613010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +8 +7 +Connector_Harting +Harting_har-flexicon_14110713001xxx_1x07-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110713001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +9 +8 +Connector_Harting +Harting_har-flexicon_14110713002xxx_1x07-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110713002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +9 +8 +Connector_Harting +Harting_har-flexicon_14110713010xxx_1x07-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110713010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +9 +8 +Connector_Harting +Harting_har-flexicon_14110813001xxx_1x08-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110813001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +10 +9 +Connector_Harting +Harting_har-flexicon_14110813002xxx_1x08-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110813002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +10 +9 +Connector_Harting +Harting_har-flexicon_14110813010xxx_1x08-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110813010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +10 +9 +Connector_Harting +Harting_har-flexicon_14110913001xxx_1x09-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14110913001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +11 +10 +Connector_Harting +Harting_har-flexicon_14110913002xxx_1x09-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110913002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +11 +10 +Connector_Harting +Harting_har-flexicon_14110913010xxx_1x09-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14110913010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +11 +10 +Connector_Harting +Harting_har-flexicon_14111013001xxx_1x10-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14111013001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +12 +11 +Connector_Harting +Harting_har-flexicon_14111013002xxx_1x10-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111013002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +12 +11 +Connector_Harting +Harting_har-flexicon_14111013010xxx_1x10-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111013010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +12 +11 +Connector_Harting +Harting_har-flexicon_14111113001xxx_1x11-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14111113001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +13 +12 +Connector_Harting +Harting_har-flexicon_14111113002xxx_1x11-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111113002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +13 +12 +Connector_Harting +Harting_har-flexicon_14111113010xxx_1x11-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111113010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +13 +12 +Connector_Harting +Harting_har-flexicon_14111213001xxx_1x12-MP_P2.54mm_Vertical +Harting har-flexicon series connector, 14111213001xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13001XXX_100228421DRW046C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon vertical +0 +14 +13 +Connector_Harting +Harting_har-flexicon_14111213002xxx_1x12-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111213002xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13002XXX_100228421DRW035C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +14 +13 +Connector_Harting +Harting_har-flexicon_14111213010xxx_1x12-MP_P2.54mm_Horizontal +Harting har-flexicon series connector, 14111213010xxx (https://b2b.harting.com/files/download/PRD/PDF_TS/1411XX13010XXX_100228421DRW063C.pdf), generated with kicad-footprint-generator +connector Harting har-flexicon horizontal +0 +14 +13 +Connector_Harwin +Harwin_Gecko-G125-FVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row female, vertical entry, PN:G125-FVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-FVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row female, vertical entry, PN:G125-FVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-FVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row female, vertical entry, PN:G125-FVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-FVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row female, vertical entry, PN:G125-FVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-FVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row female, vertical entry, PN:G125-FVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-FVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row female, vertical entry, PN:G125-FVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-FVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row female, vertical entry, PN:G125-FVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-FVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row female, vertical entry, PN:G125-FVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L0X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, no latches, PN:G125-MVX0605L0X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX0605L1X_2x03_P1.25mm_Vertical +Harwin Gecko Connector, 6 pins, dual row male, vertical entry, with latches, PN:G125-MVX0605L1X +connector harwin gecko +0 +6 +6 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L0X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, no latches, PN:G125-MVX1005L0X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1005L1X_2x05_P1.25mm_Vertical +Harwin Gecko Connector, 10 pins, dual row male, vertical entry, with latches, PN:G125-MVX1005L1X +connector harwin gecko +0 +10 +10 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L0X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, no latches, PN:G125-MVX1205L0X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1205L1X_2x06_P1.25mm_Vertical +Harwin Gecko Connector, 12 pins, dual row male, vertical entry, with latches, PN:G125-MVX1205L1X +connector harwin gecko +0 +12 +12 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L0X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, no latches, PN:G125-MVX1605L0X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX1605L1X_2x08_P1.25mm_Vertical +Harwin Gecko Connector, 16 pins, dual row male, vertical entry, with latches, PN:G125-MVX1605L1X +connector harwin gecko +0 +16 +16 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L0X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, no latches, PN:G125-MVX2005L0X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2005L1X_2x10_P1.25mm_Vertical +Harwin Gecko Connector, 20 pins, dual row male, vertical entry, with latches, PN:G125-MVX2005L1X +connector harwin gecko +0 +20 +20 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L0X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, no latches, PN:G125-MVX2605L0X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX2605L1X_2x13_P1.25mm_Vertical +Harwin Gecko Connector, 26 pins, dual row male, vertical entry, with latches, PN:G125-MVX2605L1X +connector harwin gecko +0 +26 +26 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L0X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, no latches, PN:G125-MVX3405L0X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX3405L1X_2x17_P1.25mm_Vertical +Harwin Gecko Connector, 34 pins, dual row male, vertical entry, with latches, PN:G125-MVX3405L1X +connector harwin gecko +0 +34 +34 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L0X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, no latches, PN:G125-MVX5005L0X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_Gecko-G125-MVX5005L1X_2x25_P1.25mm_Vertical +Harwin Gecko Connector, 50 pins, dual row male, vertical entry, with latches, PN:G125-MVX5005L1X +connector harwin gecko +0 +50 +50 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical +Harwin LTek Connector, 2 pins, single row male, vertical entry +connector harwin ltek M80 +0 +2 +2 +Connector_Harwin +Harwin_LTek-Male_02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 2 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +6 +2 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_2x02_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_2x03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical +Harwin LTek Connector, 8 pins, single row male, vertical entry +connector harwin ltek M80 +0 +8 +8 +Connector_Harwin +Harwin_LTek-Male_2x04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 8 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +12 +8 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical +Harwin LTek Connector, 10 pins, single row male, vertical entry +connector harwin ltek M80 +0 +10 +10 +Connector_Harwin +Harwin_LTek-Male_2x05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 10 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +14 +10 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical +Harwin LTek Connector, 12 pins, single row male, vertical entry +connector harwin ltek M80 +0 +12 +12 +Connector_Harwin +Harwin_LTek-Male_2x06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 12 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +16 +12 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical +Harwin LTek Connector, 14 pins, single row male, vertical entry +connector harwin ltek M80 +0 +14 +14 +Connector_Harwin +Harwin_LTek-Male_2x07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 14 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +18 +14 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical +Harwin LTek Connector, 16 pins, single row male, vertical entry +connector harwin ltek M80 +0 +16 +16 +Connector_Harwin +Harwin_LTek-Male_2x08_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 16 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +20 +16 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical +Harwin LTek Connector, 18 pins, single row male, vertical entry +connector harwin ltek M80 +0 +18 +18 +Connector_Harwin +Harwin_LTek-Male_2x09_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 18 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +22 +18 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical +Harwin LTek Connector, 20 pins, single row male, vertical entry +connector harwin ltek M80 +0 +20 +20 +Connector_Harwin +Harwin_LTek-Male_2x10_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 20 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +24 +20 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical +Harwin LTek Connector, 26 pins, single row male, vertical entry +connector harwin ltek M80 +0 +26 +26 +Connector_Harwin +Harwin_LTek-Male_2x13_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 26 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +30 +26 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical +Harwin LTek Connector, 34 pins, single row male, vertical entry +connector harwin ltek M80 +0 +34 +34 +Connector_Harwin +Harwin_LTek-Male_2x17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 34 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +38 +34 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical +Harwin LTek Connector, 44 pins, single row male, vertical entry +connector harwin ltek M80 +0 +44 +44 +Connector_Harwin +Harwin_LTek-Male_2x22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 44 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +48 +44 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical +Harwin LTek Connector, 3 pins, single row male, vertical entry +connector harwin ltek M80 +0 +3 +3 +Connector_Harwin +Harwin_LTek-Male_03_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 3 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +7 +3 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical +Harwin LTek Connector, 4 pins, single row male, vertical entry +connector harwin ltek M80 +0 +4 +4 +Connector_Harwin +Harwin_LTek-Male_04_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 4 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +8 +4 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical +Harwin LTek Connector, 5 pins, single row male, vertical entry +connector harwin ltek M80 +0 +5 +5 +Connector_Harwin +Harwin_LTek-Male_05_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 5 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +9 +5 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical +Harwin LTek Connector, 6 pins, single row male, vertical entry +connector harwin ltek M80 +0 +6 +6 +Connector_Harwin +Harwin_LTek-Male_06_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 6 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +10 +6 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical +Harwin LTek Connector, 7 pins, single row male, vertical entry +connector harwin ltek M80 +0 +7 +7 +Connector_Harwin +Harwin_LTek-Male_07_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 7 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +11 +7 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical +Harwin LTek Connector, 17 pins, single row male, vertical entry +connector harwin ltek M80 +0 +17 +17 +Connector_Harwin +Harwin_LTek-Male_17_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 17 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +21 +17 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical +Harwin LTek Connector, 22 pins, single row male, vertical entry +connector harwin ltek M80 +0 +22 +22 +Connector_Harwin +Harwin_LTek-Male_22_P2.00mm_Vertical_StrainRelief +Harwin LTek Connector, 22 pins, single row male, vertical entry, strain relief clip +connector harwin ltek M80 +0 +26 +22 +Connector_Harwin +Harwin_M20-89003xx_1x03_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89003xx, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +4 +3 +Connector_Harwin +Harwin_M20-89004xx_1x04_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89004xx, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +5 +4 +Connector_Harwin +Harwin_M20-89005xx_1x05_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89005xx, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +6 +5 +Connector_Harwin +Harwin_M20-89006xx_1x06_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89006xx, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +7 +6 +Connector_Harwin +Harwin_M20-89007xx_1x07_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89007xx, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +8 +7 +Connector_Harwin +Harwin_M20-89008xx_1x08_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89008xx, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +9 +8 +Connector_Harwin +Harwin_M20-89009xx_1x09_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89009xx, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +10 +9 +Connector_Harwin +Harwin_M20-89010xx_1x10_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89010xx, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +11 +10 +Connector_Harwin +Harwin_M20-89011xx_1x11_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89011xx, 11 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +12 +11 +Connector_Harwin +Harwin_M20-89012xx_1x12_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89012xx, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +13 +12 +Connector_Harwin +Harwin_M20-89013xx_1x13_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89013xx, 13 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +14 +13 +Connector_Harwin +Harwin_M20-89014xx_1x14_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89014xx, 14 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +15 +14 +Connector_Harwin +Harwin_M20-89015xx_1x15_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89015xx, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +16 +15 +Connector_Harwin +Harwin_M20-89016xx_1x16_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89016xx, 16 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +17 +16 +Connector_Harwin +Harwin_M20-89017xx_1x17_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89017xx, 17 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +18 +17 +Connector_Harwin +Harwin_M20-89018xx_1x18_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89018xx, 18 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +19 +18 +Connector_Harwin +Harwin_M20-89019xx_1x19_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89019xx, 19 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +20 +19 +Connector_Harwin +Harwin_M20-89020xx_1x20_P2.54mm_Horizontal +Harwin Male Horizontal Surface Mount Single Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-89020xx, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-890.pdf), generated with kicad-footprint-generator +connector Harwin M20-890 horizontal +0 +21 +20 +Connector_Harwin +Harwin_M20-7810245_2x02_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810245, 2 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +4 +4 +Connector_Harwin +Harwin_M20-7810345_2x03_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810345, 3 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +6 +6 +Connector_Harwin +Harwin_M20-7810445_2x04_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810445, 4 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +8 +8 +Connector_Harwin +Harwin_M20-7810545_2x05_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810545, 5 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +10 +10 +Connector_Harwin +Harwin_M20-7810645_2x06_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810645, 6 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +12 +12 +Connector_Harwin +Harwin_M20-7810745_2x07_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810745, 7 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +14 +14 +Connector_Harwin +Harwin_M20-7810845_2x08_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810845, 8 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +16 +16 +Connector_Harwin +Harwin_M20-7810945_2x09_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7810945, 9 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +18 +18 +Connector_Harwin +Harwin_M20-7811045_2x10_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811045, 10 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +20 +20 +Connector_Harwin +Harwin_M20-7811245_2x12_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811245, 12 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +24 +24 +Connector_Harwin +Harwin_M20-7811545_2x15_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7811545, 15 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +30 +30 +Connector_Harwin +Harwin_M20-7812045_2x20_P2.54mm_Vertical +Harwin Female Vertical Surface Mount Double Row 2.54mm (0.1 inch) Pitch PCB Connector, M20-7812045, 20 Pins per row (https://cdn.harwin.com/pdfs/M20-781.pdf), generated with kicad-footprint-generator +connector Harwin M20 side entry +0 +40 +40 +Connector_Hirose +Hirose_BM24_BM24-40DP-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DP/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose BM24 40pin header +0 +44 +42 +Connector_Hirose +Hirose_BM24_BM24-40DS-2-0.35V_2x20_P0.35mm_PowerPin2_Vertical +Hirose BM24 series connector, BM24-40DS/2-0.35V (https://www.hirose.com/product/en/download_file/key_name/BM24/category/Catalog/doc_file_id/47680/?file_category_id=4&item_id=50&is_series=1) +connector Hirose 40pin receptacle vertical +0 +42 +42 +Connector_Hirose +Hirose_DF3EA-02P-2H_1x02-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-02P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF3EA-03P-2H_1x03-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-03P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF3EA-04P-2H_1x04-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-04P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF3EA-05P-2H_1x05-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-05P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF3EA-06P-2H_1x06-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-06P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF3EA-07P-2H_1x07-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-07P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF3EA-08P-2H_1x08-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-08P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF3EA-09P-2H_1x09-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-09P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF3EA-10P-2H_1x10-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-10P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF3EA-11P-2H_1x11-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-11P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF3EA-12P-2H_1x12-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-12P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF3EA-13P-2H_1x13-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-13P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +15 +14 +Connector_Hirose +Hirose_DF3EA-14P-2H_1x14-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-14P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF3EA-15P-2H_1x15-1MP_P2.00mm_Horizontal +Hirose series connector, DF3EA-15P-2H (https://www.hirose.com/product/document?clcode=CL0543-0332-0-51&productname=DF3EA-5P-2H(51)&series=DF3&documenttype=2DDrawing&lang=en&documentid=0001163317), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF11-4DP-2DSA_2x02_P2.00mm_Vertical +Hirose DF11 through hole, DF11-4DP-2DSA, 2 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF11-6DP-2DSA_2x03_P2.00mm_Vertical +Hirose DF11 through hole, DF11-6DP-2DSA, 3 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF11-8DP-2DSA_2x04_P2.00mm_Vertical +Hirose DF11 through hole, DF11-8DP-2DSA, 4 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF11-10DP-2DSA_2x05_P2.00mm_Vertical +Hirose DF11 through hole, DF11-10DP-2DSA, 5 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF11-12DP-2DSA_2x06_P2.00mm_Vertical +Hirose DF11 through hole, DF11-12DP-2DSA, 6 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF11-14DP-2DSA_2x07_P2.00mm_Vertical +Hirose DF11 through hole, DF11-14DP-2DSA, 7 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF11-16DP-2DSA_2x08_P2.00mm_Vertical +Hirose DF11 through hole, DF11-16DP-2DSA, 8 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +16 +16 +Connector_Hirose +Hirose_DF11-18DP-2DSA_2x09_P2.00mm_Vertical +Hirose DF11 through hole, DF11-18DP-2DSA, 9 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +18 +18 +Connector_Hirose +Hirose_DF11-20DP-2DSA_2x10_P2.00mm_Vertical +Hirose DF11 through hole, DF11-20DP-2DSA, 10 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +20 +20 +Connector_Hirose +Hirose_DF11-22DP-2DSA_2x11_P2.00mm_Vertical +Hirose DF11 through hole, DF11-22DP-2DSA, 11 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +22 +22 +Connector_Hirose +Hirose_DF11-24DP-2DSA_2x12_P2.00mm_Vertical +Hirose DF11 through hole, DF11-24DP-2DSA, 12 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +24 +24 +Connector_Hirose +Hirose_DF11-26DP-2DSA_2x13_P2.00mm_Vertical +Hirose DF11 through hole, DF11-26DP-2DSA, 13 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +26 +26 +Connector_Hirose +Hirose_DF11-28DP-2DSA_2x14_P2.00mm_Vertical +Hirose DF11 through hole, DF11-28DP-2DSA, 14 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +28 +28 +Connector_Hirose +Hirose_DF11-30DP-2DSA_2x15_P2.00mm_Vertical +Hirose DF11 through hole, DF11-30DP-2DSA, 15 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +30 +30 +Connector_Hirose +Hirose_DF11-32DP-2DSA_2x16_P2.00mm_Vertical +Hirose DF11 through hole, DF11-32DP-2DSA, 16 Pins per row (https://www.hirose.com/product/document?clcode=&productname=&series=DF11&documenttype=Catalog&lang=en&documentid=D31688_en), generated with kicad-footprint-generator +connector Hirose DF11 vertical +0 +32 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-10DS-0.5V_2x05_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-10DS-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12C3.0-14DS-0.5V_2x07_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-14DS-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12C3.0-20DS-0.5V_2x10_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-20DS-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12C3.0-30DS-0.5V_2x15_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-30DS-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12C3.0-32DS-0.5V_2x16_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-32DS-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12C3.0-36DS-0.5V_2x18_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-36DS-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12C3.0-40DS-0.5V_2x20_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-40DS-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12C3.0-50DS-0.5V_2x25_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-50DS-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12C3.0-60DS-0.5V_2x30_P0.50mm_Vertical +Hirose DF12C SMD, DF12C3.0-60DS-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0694-9-81&productname=DF12C(3.0)-50DS-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000994748), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-10DP-0.5V_2x05_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-10DP-0.5V, 10 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +20 +10 +Connector_Hirose +Hirose_DF12_DF12E3.0-14DP-0.5V_2x07_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-14DP-0.5V, 14 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +28 +14 +Connector_Hirose +Hirose_DF12_DF12E3.0-20DP-0.5V_2x10_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-20DP-0.5V, 20 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +40 +20 +Connector_Hirose +Hirose_DF12_DF12E3.0-30DP-0.5V_2x15_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-30DP-0.5V, 30 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +60 +30 +Connector_Hirose +Hirose_DF12_DF12E3.0-32DP-0.5V_2x16_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-32DP-0.5V, 32 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +64 +32 +Connector_Hirose +Hirose_DF12_DF12E3.0-36DP-0.5V_2x18_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-36DP-0.5V, 36 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +72 +36 +Connector_Hirose +Hirose_DF12_DF12E3.0-40DP-0.5V_2x20_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-40DP-0.5V, 40 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +80 +40 +Connector_Hirose +Hirose_DF12_DF12E3.0-50DP-0.5V_2x25_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-50DP-0.5V, 50 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +100 +50 +Connector_Hirose +Hirose_DF12_DF12E3.0-60DP-0.5V_2x30_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-60DP-0.5V, 60 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +120 +60 +Connector_Hirose +Hirose_DF12_DF12E3.0-80DP-0.5V_2x40_P0.50mm_Vertical +Hirose DF12E SMD, DF12E3.0-80DP-0.5V, 80 Pins per row (https://www.hirose.com/product/document?clcode=CL0537-0834-6-81&productname=DF12E(3.0)-50DP-0.5V(81)&series=DF12&documenttype=2DDrawing&lang=en&documentid=0000992393), generated with kicad-footprint-generator +connector Hirose DF12 vertical +0 +160 +80 +Connector_Hirose +Hirose_DF13-02P-1.25DSA_1x02_P1.25mm_Vertical +Hirose DF13 through hole, DF13-02P-1.25DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF13-02P-1.25DS_1x02_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-02P-1.25DS, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +2 +2 +Connector_Hirose +Hirose_DF13-03P-1.25DSA_1x03_P1.25mm_Vertical +Hirose DF13 through hole, DF13-03P-1.25DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF13-03P-1.25DS_1x03_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-03P-1.25DS, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +3 +3 +Connector_Hirose +Hirose_DF13-04P-1.25DSA_1x04_P1.25mm_Vertical +Hirose DF13 through hole, DF13-04P-1.25DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF13-04P-1.25DS_1x04_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-04P-1.25DS, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +4 +4 +Connector_Hirose +Hirose_DF13-05P-1.25DSA_1x05_P1.25mm_Vertical +Hirose DF13 through hole, DF13-05P-1.25DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF13-05P-1.25DS_1x05_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-05P-1.25DS, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +5 +5 +Connector_Hirose +Hirose_DF13-06P-1.25DSA_1x06_P1.25mm_Vertical +Hirose DF13 through hole, DF13-06P-1.25DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF13-06P-1.25DS_1x06_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-06P-1.25DS, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +6 +6 +Connector_Hirose +Hirose_DF13-07P-1.25DSA_1x07_P1.25mm_Vertical +Hirose DF13 through hole, DF13-07P-1.25DSA, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +7 +7 +Connector_Hirose +Hirose_DF13-07P-1.25DS_1x07_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-07P-1.25DS, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +7 +7 +Connector_Hirose +Hirose_DF13-08P-1.25DSA_1x08_P1.25mm_Vertical +Hirose DF13 through hole, DF13-08P-1.25DSA, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +8 +8 +Connector_Hirose +Hirose_DF13-08P-1.25DS_1x08_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-08P-1.25DS, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +8 +8 +Connector_Hirose +Hirose_DF13-09P-1.25DSA_1x09_P1.25mm_Vertical +Hirose DF13 through hole, DF13-09P-1.25DSA, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +9 +9 +Connector_Hirose +Hirose_DF13-09P-1.25DS_1x09_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-09P-1.25DS, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +9 +9 +Connector_Hirose +Hirose_DF13-10P-1.25DSA_1x10_P1.25mm_Vertical +Hirose DF13 through hole, DF13-10P-1.25DSA, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +10 +10 +Connector_Hirose +Hirose_DF13-10P-1.25DS_1x10_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-10P-1.25DS, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +10 +10 +Connector_Hirose +Hirose_DF13-11P-1.25DSA_1x11_P1.25mm_Vertical +Hirose DF13 through hole, DF13-11P-1.25DSA, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +11 +11 +Connector_Hirose +Hirose_DF13-11P-1.25DS_1x11_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-11P-1.25DS, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +11 +11 +Connector_Hirose +Hirose_DF13-12P-1.25DSA_1x12_P1.25mm_Vertical +Hirose DF13 through hole, DF13-12P-1.25DSA, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +12 +12 +Connector_Hirose +Hirose_DF13-12P-1.25DS_1x12_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-12P-1.25DS, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +12 +12 +Connector_Hirose +Hirose_DF13-13P-1.25DSA_1x13_P1.25mm_Vertical +Hirose DF13 through hole, DF13-13P-1.25DSA, 13 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +13 +13 +Connector_Hirose +Hirose_DF13-14P-1.25DSA_1x14_P1.25mm_Vertical +Hirose DF13 through hole, DF13-14P-1.25DSA, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +14 +14 +Connector_Hirose +Hirose_DF13-14P-1.25DS_1x14_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-14P-1.25DS, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +14 +14 +Connector_Hirose +Hirose_DF13-15P-1.25DSA_1x15_P1.25mm_Vertical +Hirose DF13 through hole, DF13-15P-1.25DSA, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-2P-1.25DSA%2850%29/), generated with kicad-footprint-generator +connector Hirose DF13 vertical +0 +15 +15 +Connector_Hirose +Hirose_DF13-15P-1.25DS_1x15_P1.25mm_Horizontal +Hirose DF13 through hole, DF13-15P-1.25DS, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13-4P-1.25DS%2820%29/), generated with kicad-footprint-generator +connector Hirose DF13 horizontal +0 +15 +15 +Connector_Hirose +Hirose_DF13C_CL535-0402-2-51_1x02-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0402-2-51, 2 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +4 +3 +Connector_Hirose +Hirose_DF13C_CL535-0403-5-51_1x03-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0403-5-51, 3 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +5 +4 +Connector_Hirose +Hirose_DF13C_CL535-0404-8-51_1x04-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0404-8-51, 4 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +6 +5 +Connector_Hirose +Hirose_DF13C_CL535-0405-0-51_1x05-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0405-0-51, 5 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +7 +6 +Connector_Hirose +Hirose_DF13C_CL535-0406-3-51_1x06-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0406-3-51, 6 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +8 +7 +Connector_Hirose +Hirose_DF13C_CL535-0407-6-51_1x07-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0407-6-51, 7 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +9 +8 +Connector_Hirose +Hirose_DF13C_CL535-0408-9-51_1x08-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0408-9-51, 8 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +10 +9 +Connector_Hirose +Hirose_DF13C_CL535-0409-1-51_1x09-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0409-1-51, 9 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +11 +10 +Connector_Hirose +Hirose_DF13C_CL535-0410-4-51_1x10-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0410-4-51, 10 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +12 +11 +Connector_Hirose +Hirose_DF13C_CL535-0411-3-51_1x11-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0411-3-51, 11 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +13 +12 +Connector_Hirose +Hirose_DF13C_CL535-0412-6-51_1x12-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0412-6-51, 12 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +14 +13 +Connector_Hirose +Hirose_DF13C_CL535-0414-1-51_1x14-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0414-1-51, 14 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +16 +15 +Connector_Hirose +Hirose_DF13C_CL535-0415-4-51_1x15-1MP_P1.25mm_Vertical +Hirose DF13C SMD, CL535-0415-4-51, 15 Pins per row (https://www.hirose.com/product/en/products/DF13/DF13C-10P-1.25V%2851%29/), generated with kicad-footprint-generator +connector Hirose DF13C vertical +0 +17 +16 +Connector_Hirose +Hirose_DF52-2S-0.8H_1x02-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-2S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +4 +3 +Connector_Hirose +Hirose_DF52-3S-0.8H_1x03-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-3S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +5 +4 +Connector_Hirose +Hirose_DF52-4S-0.8H_1x04-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-4S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +6 +5 +Connector_Hirose +Hirose_DF52-5S-0.8H_1x05-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-5S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +7 +6 +Connector_Hirose +Hirose_DF52-6S-0.8H_1x06-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-6S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +8 +7 +Connector_Hirose +Hirose_DF52-7S-0.8H_1x07-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-7S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +9 +8 +Connector_Hirose +Hirose_DF52-8S-0.8H_1x08-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-8S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +10 +9 +Connector_Hirose +Hirose_DF52-9S-0.8H_1x09-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-9S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +11 +10 +Connector_Hirose +Hirose_DF52-10S-0.8H_1x10-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-10S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +12 +11 +Connector_Hirose +Hirose_DF52-11S-0.8H_1x11-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-11S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +13 +12 +Connector_Hirose +Hirose_DF52-12S-0.8H_1x12-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-12S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +14 +13 +Connector_Hirose +Hirose_DF52-14S-0.8H_1x14-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-14S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +16 +15 +Connector_Hirose +Hirose_DF52-15S-0.8H_1x15-1MP_P0.80mm_Horizontal +Hirose series connector, DF52-15S-0.8H (https://www.hirose.com/product/en/products/DF52/DF52-3S-0.8H%2821%29/), generated with kicad-footprint-generator +connector Hirose top entry +0 +17 +16 +Connector_Hirose +Hirose_DF63-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_Hirose +Hirose_DF63-6P-3.96DSA_1x06_P3.96mm_Vertical +Hirose DF63 through hole, DF63-6P-3.96DSA, 6 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +6 +6 +Connector_Hirose +Hirose_DF63M-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63M-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63M-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63M-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63M-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-1P-3.96DSA_1x01_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-1P-3.96DSA, 1 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +1 +1 +Connector_Hirose +Hirose_DF63R-2P-3.96DSA_1x02_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-2P-3.96DSA, 2 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +2 +2 +Connector_Hirose +Hirose_DF63R-3P-3.96DSA_1x03_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-3P-3.96DSA, 3 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +3 +3 +Connector_Hirose +Hirose_DF63R-4P-3.96DSA_1x04_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-4P-3.96DSA, 4 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +4 +4 +Connector_Hirose +Hirose_DF63R-5P-3.96DSA_1x05_P3.96mm_Vertical +Hirose DF63 through hole, DF63R-5P-3.96DSA, 5 Pins per row (https://www.hirose.com/product/en/products/DF63/), generated with kicad-footprint-generator +connector Hirose DF63 vertical +0 +5 +5 +Connector_IDC +IDC-Header_2x03_P2.54mm_Horizontal +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x03_P2.54mm_Vertical +Through hole IDC box header, 2x03, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x03 2.54mm double row +0 +6 +6 +Connector_IDC +IDC-Header_2x04_P2.54mm_Horizontal +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x04_P2.54mm_Vertical +Through hole IDC box header, 2x04, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x04 2.54mm double row +0 +8 +8 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +12 +11 +Connector_IDC +IDC-Header_2x05_P2.54mm_Horizontal +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Latch_Vertical +Through hole IDC header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x05_P2.54mm_Vertical +Through hole IDC box header, 2x05, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x05 2.54mm double row +0 +10 +10 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +14 +13 +Connector_IDC +IDC-Header_2x06_P2.54mm_Horizontal +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Latch_Vertical +Through hole IDC header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x06_P2.54mm_Vertical +Through hole IDC box header, 2x06, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x06 2.54mm double row +0 +12 +12 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +16 +15 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Horizontal_Lock +Connector IDC Locked, 10 contacts, compatible header: PANCON HE10 (Series 50, (https://www.reboul.fr/storage/00003af6.pdf) +connector idc locked +0 +16 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Latch_Vertical +Through hole IDC header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x07_P2.54mm_Vertical +Through hole IDC box header, 2x07, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x07 2.54mm double row +0 +14 +14 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +18 +17 +Connector_IDC +IDC-Header_2x08_P2.54mm_Horizontal +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Latch_Vertical +Through hole IDC header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x08_P2.54mm_Vertical +Through hole IDC box header, 2x08, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x08 2.54mm double row +0 +16 +16 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +22 +21 +Connector_IDC +IDC-Header_2x10_P2.54mm_Horizontal +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Latch_Vertical +Through hole IDC header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x10_P2.54mm_Vertical +Through hole IDC box header, 2x10, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x10 2.54mm double row +0 +20 +20 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +26 +25 +Connector_IDC +IDC-Header_2x12_P2.54mm_Horizontal +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Latch_Vertical +Through hole IDC header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x12_P2.54mm_Vertical +Through hole IDC box header, 2x12, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x12 2.54mm double row +0 +24 +24 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +28 +27 +Connector_IDC +IDC-Header_2x13_P2.54mm_Horizontal +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Latch_Vertical +Through hole IDC header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x13_P2.54mm_Vertical +Through hole IDC box header, 2x13, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x13 2.54mm double row +0 +26 +26 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +32 +31 +Connector_IDC +IDC-Header_2x15_P2.54mm_Horizontal +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Latch_Vertical +Through hole IDC header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x15_P2.54mm_Vertical +Through hole IDC box header, 2x15, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x15 2.54mm double row +0 +30 +30 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +36 +35 +Connector_IDC +IDC-Header_2x17_P2.54mm_Horizontal +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Latch_Vertical +Through hole IDC header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x17_P2.54mm_Vertical +Through hole IDC box header, 2x17, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x17 2.54mm double row +0 +34 +34 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +42 +41 +Connector_IDC +IDC-Header_2x20_P2.54mm_Horizontal +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Latch_Vertical +Through hole IDC header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x20_P2.54mm_Vertical +Through hole IDC box header, 2x20, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x20 2.54mm double row +0 +40 +40 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +52 +51 +Connector_IDC +IDC-Header_2x25_P2.54mm_Horizontal +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Latch_Vertical +Through hole IDC header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x25_P2.54mm_Vertical +Through hole IDC box header, 2x25, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x25 2.54mm double row +0 +50 +50 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +62 +61 +Connector_IDC +IDC-Header_2x30_P2.54mm_Horizontal +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Latch_Vertical +Through hole IDC header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x30_P2.54mm_Vertical +Through hole IDC box header, 2x30, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x30 2.54mm double row +0 +60 +60 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32-1MP_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, mounting holes, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +66 +65 +Connector_IDC +IDC-Header_2x32_P2.54mm_Horizontal +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch6.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 6.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch9.5mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 9.5mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch12.0mm_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, 12.0mm latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Horizontal +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole horizontal IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Latch_Vertical +Through hole IDC header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows latches, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC header THT 2x32 2.54mm double row +0 +64 +64 +Connector_IDC +IDC-Header_2x32_P2.54mm_Vertical +Through hole IDC box header, 2x32, 2.54mm pitch, DIN 41651 / IEC 60603-13, double rows, https://docs.google.com/spreadsheets/d/16SsEcesNF15N3Lb4niX7dcUr-NY5_MFPQhobNuNppn4/edit#gid=0 +Through hole vertical IDC box header THT 2x32 2.54mm double row +0 +64 +64 +Connector_JAE +JAE_LY20-4P-DLT1_2x02_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-4P-DLT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +4 +4 +Connector_JAE +JAE_LY20-4P-DT1_2x02_P2.00mm_Vertical +Molex LY 20 series connector, LY20-4P-DT1, 2 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +4 +4 +Connector_JAE +JAE_LY20-6P-DLT1_2x03_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-6P-DLT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +6 +6 +Connector_JAE +JAE_LY20-6P-DT1_2x03_P2.00mm_Vertical +Molex LY 20 series connector, LY20-6P-DT1, 3 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +6 +6 +Connector_JAE +JAE_LY20-8P-DLT1_2x04_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-8P-DLT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +8 +8 +Connector_JAE +JAE_LY20-8P-DT1_2x04_P2.00mm_Vertical +Molex LY 20 series connector, LY20-8P-DT1, 4 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +8 +8 +Connector_JAE +JAE_LY20-10P-DLT1_2x05_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-10P-DLT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +10 +10 +Connector_JAE +JAE_LY20-10P-DT1_2x05_P2.00mm_Vertical +Molex LY 20 series connector, LY20-10P-DT1, 5 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +10 +10 +Connector_JAE +JAE_LY20-12P-DLT1_2x06_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-12P-DLT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +12 +12 +Connector_JAE +JAE_LY20-12P-DT1_2x06_P2.00mm_Vertical +Molex LY 20 series connector, LY20-12P-DT1, 6 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +12 +12 +Connector_JAE +JAE_LY20-14P-DLT1_2x07_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-14P-DLT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +14 +14 +Connector_JAE +JAE_LY20-14P-DT1_2x07_P2.00mm_Vertical +Molex LY 20 series connector, LY20-14P-DT1, 7 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +14 +14 +Connector_JAE +JAE_LY20-16P-DLT1_2x08_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-16P-DLT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +16 +16 +Connector_JAE +JAE_LY20-16P-DT1_2x08_P2.00mm_Vertical +Molex LY 20 series connector, LY20-16P-DT1, 8 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +16 +16 +Connector_JAE +JAE_LY20-18P-DLT1_2x09_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-18P-DLT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +18 +18 +Connector_JAE +JAE_LY20-18P-DT1_2x09_P2.00mm_Vertical +Molex LY 20 series connector, LY20-18P-DT1, 9 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +18 +18 +Connector_JAE +JAE_LY20-20P-DLT1_2x10_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-20P-DLT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +20 +20 +Connector_JAE +JAE_LY20-20P-DT1_2x10_P2.00mm_Vertical +Molex LY 20 series connector, LY20-20P-DT1, 10 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +20 +20 +Connector_JAE +JAE_LY20-22P-DLT1_2x11_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-22P-DLT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +22 +22 +Connector_JAE +JAE_LY20-22P-DT1_2x11_P2.00mm_Vertical +Molex LY 20 series connector, LY20-22P-DT1, 11 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +22 +22 +Connector_JAE +JAE_LY20-24P-DLT1_2x12_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-24P-DLT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +24 +24 +Connector_JAE +JAE_LY20-24P-DT1_2x12_P2.00mm_Vertical +Molex LY 20 series connector, LY20-24P-DT1, 12 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +24 +24 +Connector_JAE +JAE_LY20-26P-DLT1_2x13_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-26P-DLT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +26 +26 +Connector_JAE +JAE_LY20-26P-DT1_2x13_P2.00mm_Vertical +Molex LY 20 series connector, LY20-26P-DT1, 13 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +26 +26 +Connector_JAE +JAE_LY20-28P-DLT1_2x14_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-28P-DLT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +28 +28 +Connector_JAE +JAE_LY20-28P-DT1_2x14_P2.00mm_Vertical +Molex LY 20 series connector, LY20-28P-DT1, 14 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +28 +28 +Connector_JAE +JAE_LY20-30P-DLT1_2x15_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-30P-DLT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +30 +30 +Connector_JAE +JAE_LY20-30P-DT1_2x15_P2.00mm_Vertical +Molex LY 20 series connector, LY20-30P-DT1, 15 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +30 +30 +Connector_JAE +JAE_LY20-32P-DLT1_2x16_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-32P-DLT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +32 +32 +Connector_JAE +JAE_LY20-32P-DT1_2x16_P2.00mm_Vertical +Molex LY 20 series connector, LY20-32P-DT1, 16 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +32 +32 +Connector_JAE +JAE_LY20-34P-DLT1_2x17_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-34P-DLT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +34 +34 +Connector_JAE +JAE_LY20-34P-DT1_2x17_P2.00mm_Vertical +Molex LY 20 series connector, LY20-34P-DT1, 17 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +34 +34 +Connector_JAE +JAE_LY20-36P-DLT1_2x18_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-36P-DLT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +36 +36 +Connector_JAE +JAE_LY20-36P-DT1_2x18_P2.00mm_Vertical +Molex LY 20 series connector, LY20-36P-DT1, 18 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +36 +36 +Connector_JAE +JAE_LY20-38P-DLT1_2x19_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-38P-DLT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +38 +38 +Connector_JAE +JAE_LY20-38P-DT1_2x19_P2.00mm_Vertical +Molex LY 20 series connector, LY20-38P-DT1, 19 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +38 +38 +Connector_JAE +JAE_LY20-40P-DLT1_2x20_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-40P-DLT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +40 +40 +Connector_JAE +JAE_LY20-40P-DT1_2x20_P2.00mm_Vertical +Molex LY 20 series connector, LY20-40P-DT1, 20 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +40 +40 +Connector_JAE +JAE_LY20-42P-DLT1_2x21_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-42P-DLT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +42 +42 +Connector_JAE +JAE_LY20-42P-DT1_2x21_P2.00mm_Vertical +Molex LY 20 series connector, LY20-42P-DT1, 21 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +42 +42 +Connector_JAE +JAE_LY20-44P-DLT1_2x22_P2.00mm_Horizontal +Molex LY 20 series connector, LY20-44P-DLT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ038187.pdf), generated with kicad-footprint-generator +connector JAE top entry +0 +44 +44 +Connector_JAE +JAE_LY20-44P-DT1_2x22_P2.00mm_Vertical +Molex LY 20 series connector, LY20-44P-DT1, 22 Circuits (http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ103130.pdf), generated with kicad-footprint-generator +connector JAE side entry +0 +44 +44 +Connector_JAE +JAE_MM70-314-310B1 +http://www.heilind.com/marketing/documents/jae/JAE_MM70.pdf +connector JAE MXM +0 +280 +279 +Connector_JAE +JAE_SIM_Card_SF72S006 +SIM Card, Push-Push, https://www.jae.com/direct/topics/topics_file_download/topics_id=68892&ext_no=06&index=0&_lang=en&v=202003111511468456809 +SIM Card with Detect Switch +0 +18 +9 +Connector_PCBEdge +4UCON_10156_2x40_P1.27mm_Socket_Horizontal +4UCON 10156 Card edge socket with 80 contacts (40 each side), through-hole, http://www.4uconnector.com/online/object/4udrawing/10156.pdf +4UCON 10156 Card edge socket with 80 contacts +0 +80 +80 +Connector_PCBEdge +BUS_AT +AT ISA 16 bits Bus Edge Connector +BUS ISA AT Edge connector +0 +98 +98 +Connector_PCBEdge +BUS_PCI +PCI bus Edge Connector +PCI bus Edge Connector +0 +240 +120 +Connector_PCBEdge +BUS_PCI_Express_Mini +Mini-PCI Express bus connector (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=11) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Dual +Mini-PCI Express bus connector full size with dual clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=28) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Full +Mini-PCI Express bus connector full size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=24) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCI_Express_Mini_Half +Mini-PCI Express bus connector half size with clips (https://s3.amazonaws.com/fit-iot/download/facet-cards/documents/PCI_Express_miniCard_Electromechanical_specs_rev1.2.pdf#page=25) +mini pcie +0 +54 +53 +Connector_PCBEdge +BUS_PCIexpress_x1 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +36 +36 +Connector_PCBEdge +BUS_PCIexpress_x4 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +64 +64 +Connector_PCBEdge +BUS_PCIexpress_x8 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +98 +98 +Connector_PCBEdge +BUS_PCIexpress_x16 +PCIexpress Bus Edge Connector x1 http://www.ritrontek.com/uploadfile/2016/1026/20161026105231124.pdf#page=70 +PCIe +0 +164 +164 +Connector_PCBEdge +Samtec_MECF-05-0_-L-DV_2x05_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-0_-NP-L-DV_2x05_P1.27mm_Edge +Highspeed card edge connector for PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-01-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-01-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV-WT_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +10 +8 +Connector_PCBEdge +Samtec_MECF-05-02-L-DV_2x05_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (polarized) +conn samtec card-edge high-speed +0 +8 +8 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV-WT_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +12 +10 +Connector_PCBEdge +Samtec_MECF-05-02-NP-L-DV_2x05_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 05 contacts (not polarized) +conn samtec card-edge high-speed +0 +10 +10 +Connector_PCBEdge +Samtec_MECF-08-0_-L-DV_2x08_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-0_-NP-L-DV_2x08_P1.27mm_Edge +Highspeed card edge connector for PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-01-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-01-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV-WT_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +16 +14 +Connector_PCBEdge +Samtec_MECF-08-02-L-DV_2x08_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (polarized) +conn samtec card-edge high-speed +0 +14 +14 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV-WT_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +18 +16 +Connector_PCBEdge +Samtec_MECF-08-02-NP-L-DV_2x08_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 08 contacts (not polarized) +conn samtec card-edge high-speed +0 +16 +16 +Connector_PCBEdge +Samtec_MECF-20-0_-L-DV_2x20_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-0_-NP-L-DV_2x20_P1.27mm_Edge +Highspeed card edge connector for PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-01-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-01-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV-WT_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +40 +38 +Connector_PCBEdge +Samtec_MECF-20-02-L-DV_2x20_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (polarized) +conn samtec card-edge high-speed +0 +38 +38 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV-WT_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +42 +40 +Connector_PCBEdge +Samtec_MECF-20-02-NP-L-DV_2x20_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 20 contacts (not polarized) +conn samtec card-edge high-speed +0 +40 +40 +Connector_PCBEdge +Samtec_MECF-30-0_-L-DV_2x30_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-0_-NP-L-DV_2x30_P1.27mm_Edge +Highspeed card edge connector for PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-01-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-01-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV-WT_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +60 +58 +Connector_PCBEdge +Samtec_MECF-30-02-L-DV_2x30_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (polarized) +conn samtec card-edge high-speed +0 +58 +58 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV-WT_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +62 +60 +Connector_PCBEdge +Samtec_MECF-30-02-NP-L-DV_2x30_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 30 contacts (not polarized) +conn samtec card-edge high-speed +0 +60 +60 +Connector_PCBEdge +Samtec_MECF-40-0_-L-DV_2x40_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-0_-NP-L-DV_2x40_P1.27mm_Edge +Highspeed card edge connector for PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-01-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-01-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV-WT_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +80 +78 +Connector_PCBEdge +Samtec_MECF-40-02-L-DV_2x40_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (polarized) +conn samtec card-edge high-speed +0 +78 +78 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV-WT_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +82 +80 +Connector_PCBEdge +Samtec_MECF-40-02-NP-L-DV_2x40_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 40 contacts (not polarized) +conn samtec card-edge high-speed +0 +80 +80 +Connector_PCBEdge +Samtec_MECF-50-0_-L-DV_2x50_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-0_-NP-L-DV_2x50_P1.27mm_Edge +Highspeed card edge connector for PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-01-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-01-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV-WT_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +100 +98 +Connector_PCBEdge +Samtec_MECF-50-02-L-DV_2x50_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (polarized) +conn samtec card-edge high-speed +0 +98 +98 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV-WT_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +102 +100 +Connector_PCBEdge +Samtec_MECF-50-02-NP-L-DV_2x50_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 50 contacts (not polarized) +conn samtec card-edge high-speed +0 +100 +100 +Connector_PCBEdge +Samtec_MECF-60-0_-L-DV_2x60_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-0_-NP-L-DV_2x60_P1.27mm_Edge +Highspeed card edge connector for PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-01-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-01-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV-WT_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +118 +116 +Connector_PCBEdge +Samtec_MECF-60-02-L-DV_2x60_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (polarized) +conn samtec card-edge high-speed +0 +116 +116 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV-WT_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +122 +120 +Connector_PCBEdge +Samtec_MECF-60-02-NP-L-DV_2x60_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 60 contacts (not polarized) +conn samtec card-edge high-speed +0 +120 +120 +Connector_PCBEdge +Samtec_MECF-70-0_-L-DV_2x70_P1.27mm_Polarized_Edge +Highspeed card edge connector for PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-0_-NP-L-DV_2x70_P1.27mm_Edge +Highspeed card edge connector for PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-01-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-01-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 1.6mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV-WT_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +138 +136 +Connector_PCBEdge +Samtec_MECF-70-02-L-DV_2x70_P1.27mm_Polarized_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (polarized) +conn samtec card-edge high-speed +0 +136 +136 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV-WT_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +142 +140 +Connector_PCBEdge +Samtec_MECF-70-02-NP-L-DV_2x70_P1.27mm_Socket_Horizontal +Highspeed card edge connector for 2.4mm PCB's with 70 contacts (not polarized) +conn samtec card-edge high-speed +0 +140 +140 +Connector_PCBEdge +molex_EDGELOCK_2-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +2 +2 +Connector_PCBEdge +molex_EDGELOCK_4-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +4 +4 +Connector_PCBEdge +molex_EDGELOCK_6-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +6 +6 +Connector_PCBEdge +molex_EDGELOCK_8-CKT +https://www.molex.com/pdm_docs/sd/2008900106_sd.pdf +Connector PCBEdge molex EDGELOCK +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G-7,62_1x02_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Angled || order number: 1766233 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_2-G_1x02_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Angled || order number: 1766343 12A 630V +phoenix_contact connector GMSTBA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G-7,62_1x03_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Angled || order number: 1766246 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_3-G_1x03_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Angled || order number: 1766356 12A 630V +phoenix_contact connector GMSTBA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G-7,62_1x04_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Angled || order number: 1766259 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_4-G_1x04_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Angled || order number: 1766369 12A 630V +phoenix_contact connector GMSTBA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G-7,62_1x05_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Angled || order number: 1766262 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_5-G_1x05_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Angled || order number: 1766372 12A 630V +phoenix_contact connector GMSTBA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G-7,62_1x06_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Angled || order number: 1766275 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_6-G_1x06_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Angled || order number: 1766385 12A 630V +phoenix_contact connector GMSTBA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G-7,62_1x07_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Angled || order number: 1766288 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_7-G_1x07_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Angled || order number: 1766398 12A 630V +phoenix_contact connector GMSTBA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G-7,62_1x08_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Angled || order number: 1766291 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_8-G_1x08_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Angled || order number: 1766408 12A 630V +phoenix_contact connector GMSTBA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G-7,62_1x09_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Angled || order number: 1766301 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_9-G_1x09_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Angled || order number: 1766411 12A 630V +phoenix_contact connector GMSTBA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G-7,62_1x10_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Angled || order number: 1766314 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_10-G_1x10_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Angled || order number: 1766424 12A 630V +phoenix_contact connector GMSTBA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G-7,62_1x11_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Angled || order number: 1766327 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_11-G_1x11_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Angled || order number: 1766437 12A 630V +phoenix_contact connector GMSTBA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G-7,62_1x12_P7.62mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Angled || order number: 1766330 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBA_2,5_12-G_1x12_P7.50mm_Horizontal +Generic Phoenix Contact connector footprint for: GMSTBA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Angled || order number: 1766440 12A 630V +phoenix_contact connector GMSTBA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G-7,62_1x02_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical || order number: 1766770 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_2-G_1x02_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/2-G; number of pins: 02; pin pitch: 7.50mm; Vertical || order number: 1766660 12A 630V +phoenix_contact connector GMSTBVA_01x02_G_7.50mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G-7,62_1x03_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical || order number: 1766783 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_3-G_1x03_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/3-G; number of pins: 03; pin pitch: 7.50mm; Vertical || order number: 1766673 12A 630V +phoenix_contact connector GMSTBVA_01x03_G_7.50mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G-7,62_1x04_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical || order number: 1766796 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_4-G_1x04_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/4-G; number of pins: 04; pin pitch: 7.50mm; Vertical || order number: 1766686 12A 630V +phoenix_contact connector GMSTBVA_01x04_G_7.50mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G-7,62_1x05_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical || order number: 1766806 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_5-G_1x05_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/5-G; number of pins: 05; pin pitch: 7.50mm; Vertical || order number: 1766699 12A 630V +phoenix_contact connector GMSTBVA_01x05_G_7.50mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G-7,62_1x06_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical || order number: 1766819 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_6-G_1x06_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/6-G; number of pins: 06; pin pitch: 7.50mm; Vertical || order number: 1766709 12A 630V +phoenix_contact connector GMSTBVA_01x06_G_7.50mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G-7,62_1x07_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical || order number: 1766822 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_7-G_1x07_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/7-G; number of pins: 07; pin pitch: 7.50mm; Vertical || order number: 1766712 12A 630V +phoenix_contact connector GMSTBVA_01x07_G_7.50mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G-7,62_1x08_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical || order number: 1766835 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_8-G_1x08_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/8-G; number of pins: 08; pin pitch: 7.50mm; Vertical || order number: 1766725 12A 630V +phoenix_contact connector GMSTBVA_01x08_G_7.50mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G-7,62_1x09_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical || order number: 1766848 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_9-G_1x09_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/9-G; number of pins: 09; pin pitch: 7.50mm; Vertical || order number: 1766738 12A 630V +phoenix_contact connector GMSTBVA_01x09_G_7.50mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G-7,62_1x10_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical || order number: 1766851 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_10-G_1x10_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/10-G; number of pins: 10; pin pitch: 7.50mm; Vertical || order number: 1766741 12A 630V +phoenix_contact connector GMSTBVA_01x10_G_7.50mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G-7,62_1x11_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical || order number: 1766864 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_11-G_1x11_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/11-G; number of pins: 11; pin pitch: 7.50mm; Vertical || order number: 1766754 12A 630V +phoenix_contact connector GMSTBVA_01x11_G_7.50mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G-7,62_1x12_P7.62mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical || order number: 1766877 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBVA_2,5_12-G_1x12_P7.50mm_Vertical +Generic Phoenix Contact connector footprint for: GMSTBVA_2,5/12-G; number of pins: 12; pin pitch: 7.50mm; Vertical || order number: 1766767 12A 630V +phoenix_contact connector GMSTBVA_01x12_G_7.50mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_2-GF-7,62_1x02_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829154 12A 630V +phoenix_contact connector GMSTBV_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_3-GF-7,62_1x03_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829167 12A 630V +phoenix_contact connector GMSTBV_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_4-GF-7,62_1x04_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829170 12A 630V +phoenix_contact connector GMSTBV_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_5-GF-7,62_1x05_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829183 12A 630V +phoenix_contact connector GMSTBV_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_6-GF-7,62_1x06_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829196 12A 630V +phoenix_contact connector GMSTBV_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_7-GF-7,62_1x07_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829206 12A 630V +phoenix_contact connector GMSTBV_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_8-GF-7,62_1x08_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829219 12A 630V +phoenix_contact connector GMSTBV_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_9-GF-7,62_1x09_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829222 12A 630V +phoenix_contact connector GMSTBV_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_10-GF-7,62_1x10_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829235 12A 630V +phoenix_contact connector GMSTBV_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_11-GF-7,62_1x11_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829248 12A 630V +phoenix_contact connector GMSTBV_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTBV_2,5_12-GF-7,62_1x12_P7.62mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTBV_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1829251 12A 630V +phoenix_contact connector GMSTBV_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_2-GF-7,62_1x02_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/2-GF-7,62; number of pins: 02; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806229 12A 630V +phoenix_contact connector GMSTB_01x02_GF_7.62mm_MH +0 +2 +2 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_3-GF-7,62_1x03_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/3-GF-7,62; number of pins: 03; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806232 12A 630V +phoenix_contact connector GMSTB_01x03_GF_7.62mm_MH +0 +3 +3 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_4-GF-7,62_1x04_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/4-GF-7,62; number of pins: 04; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806245 12A 630V +phoenix_contact connector GMSTB_01x04_GF_7.62mm_MH +0 +4 +4 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_5-GF-7,62_1x05_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/5-GF-7,62; number of pins: 05; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806258 12A 630V +phoenix_contact connector GMSTB_01x05_GF_7.62mm_MH +0 +5 +5 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_6-GF-7,62_1x06_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/6-GF-7,62; number of pins: 06; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806261 12A 630V +phoenix_contact connector GMSTB_01x06_GF_7.62mm_MH +0 +6 +6 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_7-GF-7,62_1x07_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/7-GF-7,62; number of pins: 07; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806274 12A 630V +phoenix_contact connector GMSTB_01x07_GF_7.62mm_MH +0 +7 +7 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_8-GF-7,62_1x08_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/8-GF-7,62; number of pins: 08; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806287 12A 630V +phoenix_contact connector GMSTB_01x08_GF_7.62mm_MH +0 +8 +8 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_9-GF-7,62_1x09_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/9-GF-7,62; number of pins: 09; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806290 12A 630V +phoenix_contact connector GMSTB_01x09_GF_7.62mm_MH +0 +9 +9 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_10-GF-7,62_1x10_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/10-GF-7,62; number of pins: 10; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806300 12A 630V +phoenix_contact connector GMSTB_01x10_GF_7.62mm_MH +0 +10 +10 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_11-GF-7,62_1x11_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/11-GF-7,62; number of pins: 11; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806313 12A 630V +phoenix_contact connector GMSTB_01x11_GF_7.62mm_MH +0 +11 +11 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm +0 +12 +12 +Connector_Phoenix_GMSTB +PhoenixContact_GMSTB_2,5_12-GF-7,62_1x12_P7.62mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: GMSTB_2,5/12-GF-7,62; number of pins: 12; pin pitch: 7.62mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x6.5 C or ISO 7049-ST 2.2x6.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1806326 12A 630V +phoenix_contact connector GMSTB_01x12_GF_7.62mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.5_1x02_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical || order number: 1843606 8A 160V +phoenix_contact connector MCV_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-G-3.81_1x02_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical || order number: 1803426 8A 160V +phoenix_contact connector MCV_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.5_1x02_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843224 8A 160V +phoenix_contact connector MCV_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_2-GF-3.81_1x02_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830596 8A 160V +phoenix_contact connector MCV_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.5_1x03_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical || order number: 1843619 8A 160V +phoenix_contact connector MCV_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-G-3.81_1x03_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical || order number: 1803439 8A 160V +phoenix_contact connector MCV_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.5_1x03_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843237 8A 160V +phoenix_contact connector MCV_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_3-GF-3.81_1x03_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830606 8A 160V +phoenix_contact connector MCV_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.5_1x04_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical || order number: 1843622 8A 160V +phoenix_contact connector MCV_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-G-3.81_1x04_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical || order number: 1803442 8A 160V +phoenix_contact connector MCV_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.5_1x04_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843240 8A 160V +phoenix_contact connector MCV_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_4-GF-3.81_1x04_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830619 8A 160V +phoenix_contact connector MCV_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.5_1x05_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical || order number: 1843635 8A 160V +phoenix_contact connector MCV_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-G-3.81_1x05_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical || order number: 1803455 8A 160V +phoenix_contact connector MCV_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.5_1x05_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843253 8A 160V +phoenix_contact connector MCV_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_5-GF-3.81_1x05_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830622 8A 160V +phoenix_contact connector MCV_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.5_1x06_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical || order number: 1843648 8A 160V +phoenix_contact connector MCV_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-G-3.81_1x06_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical || order number: 1803468 8A 160V +phoenix_contact connector MCV_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.5_1x06_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843266 8A 160V +phoenix_contact connector MCV_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_6-GF-3.81_1x06_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830635 8A 160V +phoenix_contact connector MCV_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.5_1x07_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical || order number: 1843651 8A 160V +phoenix_contact connector MCV_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-G-3.81_1x07_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical || order number: 1803471 8A 160V +phoenix_contact connector MCV_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.5_1x07_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843279 8A 160V +phoenix_contact connector MCV_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_7-GF-3.81_1x07_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830648 8A 160V +phoenix_contact connector MCV_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.5_1x08_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical || order number: 1843664 8A 160V +phoenix_contact connector MCV_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-G-3.81_1x08_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical || order number: 1803484 8A 160V +phoenix_contact connector MCV_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.5_1x08_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843282 8A 160V +phoenix_contact connector MCV_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_8-GF-3.81_1x08_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830651 8A 160V +phoenix_contact connector MCV_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.5_1x09_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical || order number: 1843677 8A 160V +phoenix_contact connector MCV_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-G-3.81_1x09_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical || order number: 1803497 8A 160V +phoenix_contact connector MCV_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.5_1x09_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843295 8A 160V +phoenix_contact connector MCV_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_9-GF-3.81_1x09_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830664 8A 160V +phoenix_contact connector MCV_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.5_1x10_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical || order number: 1843680 8A 160V +phoenix_contact connector MCV_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-G-3.81_1x10_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical || order number: 1803507 8A 160V +phoenix_contact connector MCV_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.5_1x10_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843305 8A 160V +phoenix_contact connector MCV_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_10-GF-3.81_1x10_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830677 8A 160V +phoenix_contact connector MCV_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.5_1x11_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical || order number: 1843693 8A 160V +phoenix_contact connector MCV_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-G-3.81_1x11_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical || order number: 1803510 8A 160V +phoenix_contact connector MCV_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.5_1x11_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843318 8A 160V +phoenix_contact connector MCV_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_11-GF-3.81_1x11_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830680 8A 160V +phoenix_contact connector MCV_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.5_1x12_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical || order number: 1843703 8A 160V +phoenix_contact connector MCV_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-G-3.81_1x12_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical || order number: 1803523 8A 160V +phoenix_contact connector MCV_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.5_1x12_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843321 8A 160V +phoenix_contact connector MCV_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_12-GF-3.81_1x12_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830693 8A 160V +phoenix_contact connector MCV_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.5_1x13_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical || order number: 1843716 8A 160V +phoenix_contact connector MCV_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-G-3.81_1x13_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical || order number: 1803536 8A 160V +phoenix_contact connector MCV_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.5_1x13_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843334 8A 160V +phoenix_contact connector MCV_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_13-GF-3.81_1x13_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830703 8A 160V +phoenix_contact connector MCV_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.5_1x14_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical || order number: 1843729 8A 160V +phoenix_contact connector MCV_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-G-3.81_1x14_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical || order number: 1803549 8A 160V +phoenix_contact connector MCV_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.5_1x14_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843347 8A 160V +phoenix_contact connector MCV_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_14-GF-3.81_1x14_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830716 8A 160V +phoenix_contact connector MCV_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.5_1x15_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical || order number: 1843732 8A 160V +phoenix_contact connector MCV_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-G-3.81_1x15_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical || order number: 1803552 8A 160V +phoenix_contact connector MCV_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.5_1x15_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843350 8A 160V +phoenix_contact connector MCV_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_15-GF-3.81_1x15_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830729 8A 160V +phoenix_contact connector MCV_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.5_1x16_P3.50mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical || order number: 1843745 8A 160V +phoenix_contact connector MCV_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-G-3.81_1x16_P3.81mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical || order number: 1803565 8A 160V +phoenix_contact connector MCV_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.5_1x16_P3.50mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843363 8A 160V +phoenix_contact connector MCV_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MCV_1,5_16-GF-3.81_1x16_P3.81mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1830732 8A 160V +phoenix_contact connector MCV_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.5_1x02_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.5; number of pins: 02; pin pitch: 3.50mm; Angled || order number: 1844210 8A 160V +phoenix_contact connector MC_01x02_G_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-G-3.81_1x02_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-3.81; number of pins: 02; pin pitch: 3.81mm; Angled || order number: 1803277 8A 160V +phoenix_contact connector MC_01x02_G_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.5_1x02_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.5; number of pins: 02; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843790 8A 160V +phoenix_contact connector MC_01x02_GF_3.5mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_2-GF-3.81_1x02_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-3.81; number of pins: 02; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827868 8A 160V +phoenix_contact connector MC_01x02_GF_3.81mm_MH +0 +2 +2 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.5_1x03_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.5; number of pins: 03; pin pitch: 3.50mm; Angled || order number: 1844223 8A 160V +phoenix_contact connector MC_01x03_G_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-G-3.81_1x03_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-3.81; number of pins: 03; pin pitch: 3.81mm; Angled || order number: 1803280 8A 160V +phoenix_contact connector MC_01x03_G_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.5_1x03_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.5; number of pins: 03; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843800 8A 160V +phoenix_contact connector MC_01x03_GF_3.5mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_3-GF-3.81_1x03_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-3.81; number of pins: 03; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827871 8A 160V +phoenix_contact connector MC_01x03_GF_3.81mm_MH +0 +3 +3 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.5_1x04_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.5; number of pins: 04; pin pitch: 3.50mm; Angled || order number: 1844236 8A 160V +phoenix_contact connector MC_01x04_G_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-G-3.81_1x04_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-3.81; number of pins: 04; pin pitch: 3.81mm; Angled || order number: 1803293 8A 160V +phoenix_contact connector MC_01x04_G_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.5_1x04_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.5; number of pins: 04; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843813 8A 160V +phoenix_contact connector MC_01x04_GF_3.5mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_4-GF-3.81_1x04_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-3.81; number of pins: 04; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827884 8A 160V +phoenix_contact connector MC_01x04_GF_3.81mm_MH +0 +4 +4 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.5_1x05_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.5; number of pins: 05; pin pitch: 3.50mm; Angled || order number: 1844249 8A 160V +phoenix_contact connector MC_01x05_G_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-G-3.81_1x05_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-3.81; number of pins: 05; pin pitch: 3.81mm; Angled || order number: 1803303 8A 160V +phoenix_contact connector MC_01x05_G_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.5_1x05_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.5; number of pins: 05; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843826 8A 160V +phoenix_contact connector MC_01x05_GF_3.5mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_5-GF-3.81_1x05_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-3.81; number of pins: 05; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827897 8A 160V +phoenix_contact connector MC_01x05_GF_3.81mm_MH +0 +5 +5 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.5_1x06_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.5; number of pins: 06; pin pitch: 3.50mm; Angled || order number: 1844252 8A 160V +phoenix_contact connector MC_01x06_G_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-G-3.81_1x06_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-3.81; number of pins: 06; pin pitch: 3.81mm; Angled || order number: 1803316 8A 160V +phoenix_contact connector MC_01x06_G_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.5_1x06_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.5; number of pins: 06; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843839 8A 160V +phoenix_contact connector MC_01x06_GF_3.5mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_6-GF-3.81_1x06_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-3.81; number of pins: 06; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827907 8A 160V +phoenix_contact connector MC_01x06_GF_3.81mm_MH +0 +6 +6 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.5_1x07_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.5; number of pins: 07; pin pitch: 3.50mm; Angled || order number: 1844265 8A 160V +phoenix_contact connector MC_01x07_G_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-G-3.81_1x07_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-3.81; number of pins: 07; pin pitch: 3.81mm; Angled || order number: 1803329 8A 160V +phoenix_contact connector MC_01x07_G_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.5_1x07_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.5; number of pins: 07; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843842 8A 160V +phoenix_contact connector MC_01x07_GF_3.5mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_7-GF-3.81_1x07_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-3.81; number of pins: 07; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827910 8A 160V +phoenix_contact connector MC_01x07_GF_3.81mm_MH +0 +7 +7 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.5_1x08_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.5; number of pins: 08; pin pitch: 3.50mm; Angled || order number: 1844278 8A 160V +phoenix_contact connector MC_01x08_G_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-G-3.81_1x08_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-3.81; number of pins: 08; pin pitch: 3.81mm; Angled || order number: 1803332 8A 160V +phoenix_contact connector MC_01x08_G_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.5_1x08_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.5; number of pins: 08; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843855 8A 160V +phoenix_contact connector MC_01x08_GF_3.5mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_8-GF-3.81_1x08_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-3.81; number of pins: 08; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827923 8A 160V +phoenix_contact connector MC_01x08_GF_3.81mm_MH +0 +8 +8 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.5_1x09_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.5; number of pins: 09; pin pitch: 3.50mm; Angled || order number: 1844281 8A 160V +phoenix_contact connector MC_01x09_G_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-G-3.81_1x09_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-3.81; number of pins: 09; pin pitch: 3.81mm; Angled || order number: 1803345 8A 160V +phoenix_contact connector MC_01x09_G_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.5_1x09_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.5; number of pins: 09; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843868 8A 160V +phoenix_contact connector MC_01x09_GF_3.5mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_9-GF-3.81_1x09_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-3.81; number of pins: 09; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827936 8A 160V +phoenix_contact connector MC_01x09_GF_3.81mm_MH +0 +9 +9 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.5_1x10_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.5; number of pins: 10; pin pitch: 3.50mm; Angled || order number: 1844294 8A 160V +phoenix_contact connector MC_01x10_G_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-G-3.81_1x10_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-3.81; number of pins: 10; pin pitch: 3.81mm; Angled || order number: 1803358 8A 160V +phoenix_contact connector MC_01x10_G_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.5_1x10_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.5; number of pins: 10; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843871 8A 160V +phoenix_contact connector MC_01x10_GF_3.5mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_10-GF-3.81_1x10_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-3.81; number of pins: 10; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827949 8A 160V +phoenix_contact connector MC_01x10_GF_3.81mm_MH +0 +10 +10 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.5_1x11_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.5; number of pins: 11; pin pitch: 3.50mm; Angled || order number: 1844304 8A 160V +phoenix_contact connector MC_01x11_G_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-G-3.81_1x11_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-3.81; number of pins: 11; pin pitch: 3.81mm; Angled || order number: 1803361 8A 160V +phoenix_contact connector MC_01x11_G_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.5_1x11_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.5; number of pins: 11; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843884 8A 160V +phoenix_contact connector MC_01x11_GF_3.5mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_11-GF-3.81_1x11_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-3.81; number of pins: 11; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827952 8A 160V +phoenix_contact connector MC_01x11_GF_3.81mm_MH +0 +11 +11 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.5_1x12_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.5; number of pins: 12; pin pitch: 3.50mm; Angled || order number: 1844317 8A 160V +phoenix_contact connector MC_01x12_G_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-G-3.81_1x12_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-3.81; number of pins: 12; pin pitch: 3.81mm; Angled || order number: 1803374 8A 160V +phoenix_contact connector MC_01x12_G_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.5_1x12_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.5; number of pins: 12; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843897 8A 160V +phoenix_contact connector MC_01x12_GF_3.5mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_12-GF-3.81_1x12_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-3.81; number of pins: 12; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827965 8A 160V +phoenix_contact connector MC_01x12_GF_3.81mm_MH +0 +12 +12 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.5_1x13_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.5; number of pins: 13; pin pitch: 3.50mm; Angled || order number: 1844320 8A 160V +phoenix_contact connector MC_01x13_G_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-G-3.81_1x13_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/13-G-3.81; number of pins: 13; pin pitch: 3.81mm; Angled || order number: 1803387 8A 160V +phoenix_contact connector MC_01x13_G_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.5_1x13_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.5; number of pins: 13; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843907 8A 160V +phoenix_contact connector MC_01x13_GF_3.5mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_13-GF-3.81_1x13_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/13-GF-3.81; number of pins: 13; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827978 8A 160V +phoenix_contact connector MC_01x13_GF_3.81mm_MH +0 +13 +13 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.5_1x14_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.5; number of pins: 14; pin pitch: 3.50mm; Angled || order number: 1844333 8A 160V +phoenix_contact connector MC_01x14_G_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-G-3.81_1x14_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/14-G-3.81; number of pins: 14; pin pitch: 3.81mm; Angled || order number: 1803390 8A 160V +phoenix_contact connector MC_01x14_G_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.5_1x14_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.5; number of pins: 14; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843910 8A 160V +phoenix_contact connector MC_01x14_GF_3.5mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_14-GF-3.81_1x14_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/14-GF-3.81; number of pins: 14; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827981 8A 160V +phoenix_contact connector MC_01x14_GF_3.81mm_MH +0 +14 +14 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.5_1x15_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.5; number of pins: 15; pin pitch: 3.50mm; Angled || order number: 1844346 8A 160V +phoenix_contact connector MC_01x15_G_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-G-3.81_1x15_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/15-G-3.81; number of pins: 15; pin pitch: 3.81mm; Angled || order number: 1803400 8A 160V +phoenix_contact connector MC_01x15_G_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.5_1x15_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.5; number of pins: 15; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843923 8A 160V +phoenix_contact connector MC_01x15_GF_3.5mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_15-GF-3.81_1x15_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/15-GF-3.81; number of pins: 15; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1827994 8A 160V +phoenix_contact connector MC_01x15_GF_3.81mm_MH +0 +15 +15 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.5_1x16_P3.50mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.5; number of pins: 16; pin pitch: 3.50mm; Angled || order number: 1844359 8A 160V +phoenix_contact connector MC_01x16_G_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-G-3.81_1x16_P3.81mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/16-G-3.81; number of pins: 16; pin pitch: 3.81mm; Angled || order number: 1803413 8A 160V +phoenix_contact connector MC_01x16_G_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.5_1x16_P3.50mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.5; number of pins: 16; pin pitch: 3.50mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1843936 8A 160V +phoenix_contact connector MC_01x16_GF_3.5mm_MH +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm +0 +16 +16 +Connector_Phoenix_MC +PhoenixContact_MC_1,5_16-GF-3.81_1x16_P3.81mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/16-GF-3.81; number of pins: 16; pin pitch: 3.81mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1828003 8A 160V +phoenix_contact connector MC_01x16_GF_3.81mm_MH +0 +16 +16 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-G-5.08_1x02_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical || order number: 1836299 8A 320V +phoenix_contact connector MCV_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_2-GF-5.08_1x02_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847615 8A 320V +phoenix_contact connector MCV_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-G-5.08_1x03_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical || order number: 1836309 8A 320V +phoenix_contact connector MCV_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_3-GF-5.08_1x03_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847628 8A 320V +phoenix_contact connector MCV_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-G-5.08_1x04_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical || order number: 1836312 8A 320V +phoenix_contact connector MCV_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_4-GF-5.08_1x04_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847631 8A 320V +phoenix_contact connector MCV_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-G-5.08_1x05_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical || order number: 1836325 8A 320V +phoenix_contact connector MCV_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_5-GF-5.08_1x05_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847644 8A 320V +phoenix_contact connector MCV_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-G-5.08_1x06_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical || order number: 1836338 8A 320V +phoenix_contact connector MCV_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_6-GF-5.08_1x06_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847657 8A 320V +phoenix_contact connector MCV_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-G-5.08_1x07_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical || order number: 1836341 8A 320V +phoenix_contact connector MCV_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_7-GF-5.08_1x07_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847660 8A 320V +phoenix_contact connector MCV_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-G-5.08_1x08_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical || order number: 1836354 8A 320V +phoenix_contact connector MCV_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_8-GF-5.08_1x08_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847673 8A 320V +phoenix_contact connector MCV_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-G-5.08_1x09_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical || order number: 1836367 8A 320V +phoenix_contact connector MCV_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_9-GF-5.08_1x09_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847686 8A 320V +phoenix_contact connector MCV_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-G-5.08_1x10_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical || order number: 1836370 8A 320V +phoenix_contact connector MCV_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_10-GF-5.08_1x10_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847699 8A 320V +phoenix_contact connector MCV_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-G-5.08_1x11_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical || order number: 1836383 8A 320V +phoenix_contact connector MCV_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_11-GF-5.08_1x11_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847709 8A 320V +phoenix_contact connector MCV_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-G-5.08_1x12_P5.08mm_Vertical +Generic Phoenix Contact connector footprint for: MCV_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical || order number: 1836396 8A 320V +phoenix_contact connector MCV_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MCV_1,5_12-GF-5.08_1x12_P5.08mm_Vertical_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MCV_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847712 8A 320V +phoenix_contact connector MCV_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-G-5.08_1x02_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/2-G-5.08; number of pins: 02; pin pitch: 5.08mm; Angled || order number: 1836189 8A 320V +phoenix_contact connector MC_01x02_G_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_2-GF-5.08_1x02_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/2-GF-5.08; number of pins: 02; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847466 8A 320V +phoenix_contact connector MC_01x02_GF_5.08mm_MH +0 +2 +2 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-G-5.08_1x03_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/3-G-5.08; number of pins: 03; pin pitch: 5.08mm; Angled || order number: 1836192 8A 320V +phoenix_contact connector MC_01x03_G_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_3-GF-5.08_1x03_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/3-GF-5.08; number of pins: 03; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847479 8A 320V +phoenix_contact connector MC_01x03_GF_5.08mm_MH +0 +3 +3 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-G-5.08_1x04_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/4-G-5.08; number of pins: 04; pin pitch: 5.08mm; Angled || order number: 1836202 8A 320V +phoenix_contact connector MC_01x04_G_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_4-GF-5.08_1x04_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/4-GF-5.08; number of pins: 04; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847482 8A 320V +phoenix_contact connector MC_01x04_GF_5.08mm_MH +0 +4 +4 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-G-5.08_1x05_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/5-G-5.08; number of pins: 05; pin pitch: 5.08mm; Angled || order number: 1836215 8A 320V +phoenix_contact connector MC_01x05_G_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_5-GF-5.08_1x05_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/5-GF-5.08; number of pins: 05; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847495 8A 320V +phoenix_contact connector MC_01x05_GF_5.08mm_MH +0 +5 +5 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-G-5.08_1x06_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/6-G-5.08; number of pins: 06; pin pitch: 5.08mm; Angled || order number: 1836228 8A 320V +phoenix_contact connector MC_01x06_G_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_6-GF-5.08_1x06_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/6-GF-5.08; number of pins: 06; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847505 8A 320V +phoenix_contact connector MC_01x06_GF_5.08mm_MH +0 +6 +6 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-G-5.08_1x07_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/7-G-5.08; number of pins: 07; pin pitch: 5.08mm; Angled || order number: 1836231 8A 320V +phoenix_contact connector MC_01x07_G_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_7-GF-5.08_1x07_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/7-GF-5.08; number of pins: 07; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847518 8A 320V +phoenix_contact connector MC_01x07_GF_5.08mm_MH +0 +7 +7 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-G-5.08_1x08_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/8-G-5.08; number of pins: 08; pin pitch: 5.08mm; Angled || order number: 1836244 8A 320V +phoenix_contact connector MC_01x08_G_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_8-GF-5.08_1x08_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/8-GF-5.08; number of pins: 08; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847521 8A 320V +phoenix_contact connector MC_01x08_GF_5.08mm_MH +0 +8 +8 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-G-5.08_1x09_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/9-G-5.08; number of pins: 09; pin pitch: 5.08mm; Angled || order number: 1836257 8A 320V +phoenix_contact connector MC_01x09_G_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_9-GF-5.08_1x09_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/9-GF-5.08; number of pins: 09; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847534 8A 320V +phoenix_contact connector MC_01x09_GF_5.08mm_MH +0 +9 +9 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-G-5.08_1x10_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/10-G-5.08; number of pins: 10; pin pitch: 5.08mm; Angled || order number: 1836260 8A 320V +phoenix_contact connector MC_01x10_G_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_10-GF-5.08_1x10_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/10-GF-5.08; number of pins: 10; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847547 8A 320V +phoenix_contact connector MC_01x10_GF_5.08mm_MH +0 +10 +10 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-G-5.08_1x11_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/11-G-5.08; number of pins: 11; pin pitch: 5.08mm; Angled || order number: 1836273 8A 320V +phoenix_contact connector MC_01x11_G_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_11-GF-5.08_1x11_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/11-GF-5.08; number of pins: 11; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847550 8A 320V +phoenix_contact connector MC_01x11_GF_5.08mm_MH +0 +11 +11 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-G-5.08_1x12_P5.08mm_Horizontal +Generic Phoenix Contact connector footprint for: MC_1,5/12-G-5.08; number of pins: 12; pin pitch: 5.08mm; Angled || order number: 1836286 8A 320V +phoenix_contact connector MC_01x12_G_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm +0 +12 +12 +Connector_Phoenix_MC_HighVoltage +PhoenixContact_MC_1,5_12-GF-5.08_1x12_P5.08mm_Horizontal_ThreadedFlange_MountHole +Generic Phoenix Contact connector footprint for: MC_1,5/12-GF-5.08; number of pins: 12; pin pitch: 5.08mm; Angled; threaded flange; footprint includes mount hole for mounting screw: ISO 1481-ST 2.2x4.5 C or ISO 7049-ST 2.2x4.5 C (http://www.fasteners.eu/standards/ISO/7049/) || order number: 1847563 8A 320V +phoenix_contact connector MC_01x12_GF_5.08mm_MH +0 +12 +12 +Connector_Pin +Pin_D0.7mm_L6.5mm_W1.8mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.7mm, length 6.5mm, width 1.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D0.9mm_L10.0mm_W2.4mm_FlatFork +solder Pin_ with flat fork, hole diameter 0.9mm, length 10.0mm, width 2.4mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm +solder Pin_ diameter 1.0mm, hole diameter 1.0mm (press fit), length 10.0mm +solder Pin_ press fit +0 +1 +1 +Connector_Pin +Pin_D1.0mm_L10.0mm_LooseFit +solder Pin_ diameter 1.0mm, hole diameter 1.2mm (loose fit), length 10.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L8.5mm_W2.5mm_FlatFork +solder Pin_ with flat fork, hole diameter 1.1mm, length 8.5mm, width 2.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.1mm_L10.2mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.1mm, length 10.2mm, width 3.5mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L10.2mm_W2.9mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.2mm_L11.3mm_W3.0mm_Flat +solder Pin_ with flat with hole, hole diameter 1.2mm, length 11.3mm, width 3.0mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L10.0mm_W3.5mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 10.0mm, width 3.5mm, e.g. Ettinger 13.13.865, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm +solder Pin_ diameter 1.3mm, hole diameter 1.3mm, length 11.0mm +solder Pin_ pressfit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.0mm_LooseFit +solder Pin_ diameter 1.3mm, hole diameter 1.5mm (loose fit), length 11.0mm +solder Pin_ loose fit +0 +1 +1 +Connector_Pin +Pin_D1.3mm_L11.3mm_W2.8mm_Flat +solder Pin_ with flat with hole, hole diameter 1.3mm, length 11.3mm, width 2.8mm +solder Pin_ with flat fork +0 +1 +1 +Connector_Pin +Pin_D1.4mm_L8.5mm_W2.8mm_FlatFork +solder Pin_ with flat with fork, hole diameter 1.4mm, length 8.5mm, width 2.8mm, e.g. Ettinger 13.13.890, https://katalog.ettinger.de/#p=434 +solder Pin_ with flat fork +0 +1 +1 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical +Through hole straight socket strip, 1x02, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x02 1.00mm single row +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style1 pin1 left +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x02_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x02, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x02 1.00mm single row style2 pin1 right +0 +2 +2 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical +Through hole straight socket strip, 1x03, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x03 1.00mm single row +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style1 pin1 left +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x03_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x03, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x03 1.00mm single row style2 pin1 right +0 +3 +3 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical +Through hole straight socket strip, 1x04, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x04 1.00mm single row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style1 pin1 left +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x04_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x04, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x04 1.00mm single row style2 pin1 right +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical +Through hole straight socket strip, 1x05, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x05 1.00mm single row +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style1 pin1 left +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x05_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x05, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x05 1.00mm single row style2 pin1 right +0 +5 +5 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical +Through hole straight socket strip, 1x06, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x06 1.00mm single row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style1 pin1 left +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x06_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x06, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x06 1.00mm single row style2 pin1 right +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical +Through hole straight socket strip, 1x07, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x07 1.00mm single row +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style1 pin1 left +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x07_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x07, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x07 1.00mm single row style2 pin1 right +0 +7 +7 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical +Through hole straight socket strip, 1x08, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x08 1.00mm single row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style1 pin1 left +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x08_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x08, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x08 1.00mm single row style2 pin1 right +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical +Through hole straight socket strip, 1x09, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x09 1.00mm single row +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style1 pin1 left +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x09_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x09, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x09 1.00mm single row style2 pin1 right +0 +9 +9 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical +Through hole straight socket strip, 1x10, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x10 1.00mm single row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style1 pin1 left +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x10_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x10, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x10 1.00mm single row style2 pin1 right +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical +Through hole straight socket strip, 1x11, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x11 1.00mm single row +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style1 pin1 left +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x11_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x11, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x11 1.00mm single row style2 pin1 right +0 +11 +11 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical +Through hole straight socket strip, 1x12, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x12 1.00mm single row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style1 pin1 left +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x12_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x12, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x12 1.00mm single row style2 pin1 right +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical +Through hole straight socket strip, 1x13, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x13 1.00mm single row +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style1 pin1 left +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x13_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x13, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x13 1.00mm single row style2 pin1 right +0 +13 +13 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical +Through hole straight socket strip, 1x14, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x14 1.00mm single row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style1 pin1 left +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x14_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x14, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x14 1.00mm single row style2 pin1 right +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical +Through hole straight socket strip, 1x15, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x15 1.00mm single row +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style1 pin1 left +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x15_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x15, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x15 1.00mm single row style2 pin1 right +0 +15 +15 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical +Through hole straight socket strip, 1x16, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x16 1.00mm single row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style1 pin1 left +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x16_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x16, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x16 1.00mm single row style2 pin1 right +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical +Through hole straight socket strip, 1x17, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x17 1.00mm single row +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style1 pin1 left +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x17_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x17, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x17 1.00mm single row style2 pin1 right +0 +17 +17 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical +Through hole straight socket strip, 1x18, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x18 1.00mm single row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style1 pin1 left +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x18_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x18, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x18 1.00mm single row style2 pin1 right +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical +Through hole straight socket strip, 1x19, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x19 1.00mm single row +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style1 pin1 left +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x19_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x19, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x19 1.00mm single row style2 pin1 right +0 +19 +19 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical +Through hole straight socket strip, 1x20, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x20 1.00mm single row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style1 pin1 left +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x20_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x20, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x20 1.00mm single row style2 pin1 right +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical +Through hole straight socket strip, 1x21, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x21 1.00mm single row +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style1 pin1 left +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x21_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x21, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x21 1.00mm single row style2 pin1 right +0 +21 +21 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical +Through hole straight socket strip, 1x22, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x22 1.00mm single row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style1 pin1 left +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x22_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x22, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x22 1.00mm single row style2 pin1 right +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical +Through hole straight socket strip, 1x23, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x23 1.00mm single row +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style1 pin1 left +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x23_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x23, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x23 1.00mm single row style2 pin1 right +0 +23 +23 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical +Through hole straight socket strip, 1x24, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x24 1.00mm single row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style1 pin1 left +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x24_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x24, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x24 1.00mm single row style2 pin1 right +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical +Through hole straight socket strip, 1x25, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x25 1.00mm single row +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style1 pin1 left +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x25_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x25, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x25 1.00mm single row style2 pin1 right +0 +25 +25 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical +Through hole straight socket strip, 1x26, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x26 1.00mm single row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style1 pin1 left +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x26_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x26, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x26 1.00mm single row style2 pin1 right +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical +Through hole straight socket strip, 1x27, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x27 1.00mm single row +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style1 pin1 left +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x27_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x27, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x27 1.00mm single row style2 pin1 right +0 +27 +27 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical +Through hole straight socket strip, 1x28, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x28 1.00mm single row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style1 pin1 left +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x28_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x28, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x28 1.00mm single row style2 pin1 right +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical +Through hole straight socket strip, 1x29, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x29 1.00mm single row +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style1 pin1 left +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x29_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x29, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x29 1.00mm single row style2 pin1 right +0 +29 +29 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical +Through hole straight socket strip, 1x30, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x30 1.00mm single row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style1 pin1 left +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x30_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x30, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x30 1.00mm single row style2 pin1 right +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical +Through hole straight socket strip, 1x31, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x31 1.00mm single row +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style1 pin1 left +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x31_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x31, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x31 1.00mm single row style2 pin1 right +0 +31 +31 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical +Through hole straight socket strip, 1x32, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x32 1.00mm single row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style1 pin1 left +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x32_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x32, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x32 1.00mm single row style2 pin1 right +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical +Through hole straight socket strip, 1x33, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x33 1.00mm single row +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style1 pin1 left +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x33_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x33, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x33 1.00mm single row style2 pin1 right +0 +33 +33 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical +Through hole straight socket strip, 1x34, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x34 1.00mm single row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style1 pin1 left +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x34_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x34, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x34 1.00mm single row style2 pin1 right +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical +Through hole straight socket strip, 1x35, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x35 1.00mm single row +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style1 pin1 left +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x35_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x35, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x35 1.00mm single row style2 pin1 right +0 +35 +35 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical +Through hole straight socket strip, 1x36, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x36 1.00mm single row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style1 pin1 left +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x36_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x36, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x36 1.00mm single row style2 pin1 right +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical +Through hole straight socket strip, 1x37, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x37 1.00mm single row +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style1 pin1 left +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x37_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x37, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x37 1.00mm single row style2 pin1 right +0 +37 +37 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical +Through hole straight socket strip, 1x38, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x38 1.00mm single row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style1 pin1 left +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x38_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x38, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x38 1.00mm single row style2 pin1 right +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical +Through hole straight socket strip, 1x39, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x39 1.00mm single row +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style1 pin1 left +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x39_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x39, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x39 1.00mm single row style2 pin1 right +0 +39 +39 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical +Through hole straight socket strip, 1x40, 1.00mm pitch, single row (https://gct.co/files/drawings/bc065.pdf), script generated +Through hole socket strip THT 1x40 1.00mm single row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Left +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 1 (pin 1 left) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style1 pin1 left +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_1x40_P1.00mm_Vertical_SMD_Pin1Right +surface-mounted straight socket strip, 1x40, 1.00mm pitch, single row, style 2 (pin 1 right) (https://gct.co/files/drawings/bc070.pdf), script generated +Surface mounted socket strip SMD 1x40 1.00mm single row style2 pin1 right +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x02_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x02, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x02 1.00mm double row +0 +4 +4 +Connector_PinSocket_1.00mm +PinSocket_2x03_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x03, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x03 1.00mm double row +0 +6 +6 +Connector_PinSocket_1.00mm +PinSocket_2x04_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x04, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x04 1.00mm double row +0 +8 +8 +Connector_PinSocket_1.00mm +PinSocket_2x05_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x05, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x05 1.00mm double row +0 +10 +10 +Connector_PinSocket_1.00mm +PinSocket_2x06_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x06, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x06 1.00mm double row +0 +12 +12 +Connector_PinSocket_1.00mm +PinSocket_2x07_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x07, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x07 1.00mm double row +0 +14 +14 +Connector_PinSocket_1.00mm +PinSocket_2x08_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x08, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x08 1.00mm double row +0 +16 +16 +Connector_PinSocket_1.00mm +PinSocket_2x09_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x09, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x09 1.00mm double row +0 +18 +18 +Connector_PinSocket_1.00mm +PinSocket_2x10_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x10, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x10 1.00mm double row +0 +20 +20 +Connector_PinSocket_1.00mm +PinSocket_2x11_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x11, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x11 1.00mm double row +0 +22 +22 +Connector_PinSocket_1.00mm +PinSocket_2x12_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x12, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x12 1.00mm double row +0 +24 +24 +Connector_PinSocket_1.00mm +PinSocket_2x13_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x13, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x13 1.00mm double row +0 +26 +26 +Connector_PinSocket_1.00mm +PinSocket_2x14_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x14, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x14 1.00mm double row +0 +28 +28 +Connector_PinSocket_1.00mm +PinSocket_2x15_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x15, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x15 1.00mm double row +0 +30 +30 +Connector_PinSocket_1.00mm +PinSocket_2x16_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x16, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x16 1.00mm double row +0 +32 +32 +Connector_PinSocket_1.00mm +PinSocket_2x17_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x17, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x17 1.00mm double row +0 +34 +34 +Connector_PinSocket_1.00mm +PinSocket_2x18_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x18, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x18 1.00mm double row +0 +36 +36 +Connector_PinSocket_1.00mm +PinSocket_2x19_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x19, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x19 1.00mm double row +0 +38 +38 +Connector_PinSocket_1.00mm +PinSocket_2x20_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x20, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x20 1.00mm double row +0 +40 +40 +Connector_PinSocket_1.00mm +PinSocket_2x21_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x21, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x21 1.00mm double row +0 +42 +42 +Connector_PinSocket_1.00mm +PinSocket_2x22_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x22, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x22 1.00mm double row +0 +44 +44 +Connector_PinSocket_1.00mm +PinSocket_2x23_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x23, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x23 1.00mm double row +0 +46 +46 +Connector_PinSocket_1.00mm +PinSocket_2x24_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x24, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x24 1.00mm double row +0 +48 +48 +Connector_PinSocket_1.00mm +PinSocket_2x25_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x25, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x25 1.00mm double row +0 +50 +50 +Connector_PinSocket_1.00mm +PinSocket_2x26_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x26, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x26 1.00mm double row +0 +52 +52 +Connector_PinSocket_1.00mm +PinSocket_2x27_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x27, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x27 1.00mm double row +0 +54 +54 +Connector_PinSocket_1.00mm +PinSocket_2x28_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x28, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x28 1.00mm double row +0 +56 +56 +Connector_PinSocket_1.00mm +PinSocket_2x29_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x29, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x29 1.00mm double row +0 +58 +58 +Connector_PinSocket_1.00mm +PinSocket_2x30_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x30, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x30 1.00mm double row +0 +60 +60 +Connector_PinSocket_1.00mm +PinSocket_2x31_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x31, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x31 1.00mm double row +0 +62 +62 +Connector_PinSocket_1.00mm +PinSocket_2x32_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x32, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x32 1.00mm double row +0 +64 +64 +Connector_PinSocket_1.00mm +PinSocket_2x33_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x33, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x33 1.00mm double row +0 +66 +66 +Connector_PinSocket_1.00mm +PinSocket_2x34_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x34, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x34 1.00mm double row +0 +68 +68 +Connector_PinSocket_1.00mm +PinSocket_2x35_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x35, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x35 1.00mm double row +0 +70 +70 +Connector_PinSocket_1.00mm +PinSocket_2x36_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x36, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x36 1.00mm double row +0 +72 +72 +Connector_PinSocket_1.00mm +PinSocket_2x37_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x37, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x37 1.00mm double row +0 +74 +74 +Connector_PinSocket_1.00mm +PinSocket_2x38_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x38, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x38 1.00mm double row +0 +76 +76 +Connector_PinSocket_1.00mm +PinSocket_2x39_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x39, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x39 1.00mm double row +0 +78 +78 +Connector_PinSocket_1.00mm +PinSocket_2x40_P1.00mm_Vertical_SMD +surface-mounted straight socket strip, 2x40, 1.00mm pitch, double cols (https://gct.co/files/drawings/bc085.pdf), script generated +Surface mounted socket strip SMD 2x40 1.00mm double row +0 +80 +80 +Connector_RJ +RJ12_Amphenol_54601 +RJ12 connector https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0082.pdf +RJ12 connector +0 +6 +6 +Connector_RJ +RJ14_Connfly_DS1133-S4_Horizontal +RJ14 connector 6P4C Horizontal http://www.connfly.com/userfiles/image/UpLoadFile/File/2012/10/26/DS1133.pdf +RJ14 connector 6P4C Connfly DS1133 +0 +4 +4 +Connector_RJ +RJ25_Wayconn_MJEA-660X1_Horizontal +RJ25 6P6C Socket 90 degrees, https://wayconn.com/wp-content/themes/way/datasheet/MJEA-660X1XXX_RJ25_6P6C_PCB_RA.pdf +RJ12 RJ18 RJ25 jack connector 6P6C +0 +6 +6 +Connector_RJ +RJ45_Abracon_ARJP11A-MA_Horizontal +Shielded RJ45 ethernet connector with transformer and POE (https://abracon.com/Magnetics/lan/ARJP11A.PDF) +ethernet 8p8c transformer poe rj45 +0 +15 +14 +Connector_RJ +RJ45_Amphenol_54602-x08_Horizontal +8 Pol Shallow Latch Connector, Modjack, RJ45 (https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/c-bmj-0102.pdf) +RJ45 +0 +8 +8 +Connector_RJ +RJ45_Amphenol_RJHSE538X +Shielded, 2 LED, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +14 +13 +Connector_RJ +RJ45_Amphenol_RJHSE538X-02 +Shielded, 2 LED, 2 Ports, http://www.amphenolinfocom.eu/NavData/Drawings/RJHSE-538X-02-REVC.pdf +RJ45 8p8c dual ethernet cat5 +0 +26 +25 +Connector_RJ +RJ45_Amphenol_RJHSE5380 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X.pdf +RJ45 8p8c ethernet cat5 +0 +10 +9 +Connector_RJ +RJ45_Amphenol_RJHSE5380-08 +Shielded, https://www.amphenolcanada.com/ProductSearch/drawings/AC/RJHSE538X08.pdf +RJ45 8p8c ethernet cat5 +0 +68 +65 +Connector_RJ +RJ45_Amphenol_RJMG1BD3B8K1ANR +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, AutoMDIX, https://www.amphenolcanada.com/ProductSearch/Drawings/AC/RJMG1BD3B8K1ANR.PDF +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_BEL_SS74301-00x_Vertical +https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-74301-001-ss-74301-002-ss-74301-005.pdf +RJ45 Vertical Shield LED Green Yellow +0 +14 +13 +Connector_RJ +RJ45_Bel_SI-60062-F +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, AutoMDIX, https://belfuse.com/resources/drawings/magneticsolutions/dr-mag-si-60062-f.pdf +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Cetus_J1B1211CCD_Horizontal +1 Port RJ45 Magjack Connector Through Hole 10/100 Base-T, Cetus, used and distributed by WIZnet (https://wizwiki.net/wiki/lib/exe/fetch.php?media=products:wiz550web:wiz550webds_kr:j1b1211ccd.pdf) +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Hanrun_HR911105A +http://www.kosmodrom.com.ua/pdf/HR911105A.pdf +RJ45 Magjack +0 +14 +13 +Connector_RJ +RJ45_Kycon_G7LX-A88S7-BP-xx_Horizontal +10/100Base-T RJ45 ethernet magnetic transformer connector horizontal with green/yellow LEDs http://www.kycon.com/Pub_Eng_Draw/G7LX-A88S7-BP-GY.pdf +RJ45 ethernet magnetic +0 +16 +15 +Connector_RJ +RJ45_Molex_0855135013_Vertical +1 Port, RJ45, Series 85513, vertical, SMD, https://www.molex.com/pdm_docs/sd/855135013_sd.pdf +RJ45 Vertical +0 +9 +9 +Connector_RJ +RJ45_Ninigi_GE +1 port ethernet throughhole connector, https://en.ninigi.com/product/rj45ge/pdf +RJ45 ethernet 8p8c +0 +10 +9 +Connector_RJ +RJ45_OST_PJ012-8P8CX_Vertical +RJ45 vertical connector https://www.on-shore.com/wp-content/uploads/PJ012-8P8CX.pdf +RJ45 PJ012 +0 +8 +8 +Connector_RJ +RJ45_Plug_Metz_AJP92A8813 +plug, ethernet, 8P8C, RJ45 Plug +AJP92A8813 8P8C RJ45 ethernet plug +0 +8 +8 +Connector_RJ +RJ45_Pulse_JK0654219NL_Horizontal +10/100/1000 Base-T RJ45 single port with LEDs https://media.digikey.com/pdf/Data%20Sheets/Pulse%20PDFs/JK%20Series.pdf#page=2 +RJ45 8p8c ethernet +0 +18 +17 +Connector_RJ +RJ45_Pulse_JXD6-0001NL_Horizontal +RJ45 ethernet transformer with magnetics (https://productfinder.pulseeng.com/doc_type/WEB301/doc_num/JXD6-0001NL/doc_part/JXD6-0001NL.pdf) +ethernet 8p8c transformer magjack +0 +12 +11 +Connector_RJ +RJ45_UDE_RB1-125B8G1A +1 Port RJ45 Connector Through Hole 10/100/1000 Base-T, https://datasheet.lcsc.com/szlcsc/1901091107_UDE-Corp-RB1-125B8G1A_C363353.pdf#page=3 +RJ45 ethernet +0 +16 +15 +Connector_RJ +RJ45_Wuerth_7499010001A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal https://katalog.we-online.de/pbs/datasheet/7499010001A.pdf +RJ45 ethernet magnetic +0 +10 +9 +Connector_RJ +RJ45_Wuerth_7499010121A_Horizontal +10/100Base-TX RJ45 ethernet magnetic transformer connector horizontal with green/orange LEDs https://katalog.we-online.de/pbs/datasheet/7499010121A.pdf +RJ45 ethernet magnetic +0 +14 +13 +Connector_RJ +RJ45_Wuerth_7499111446_Horizontal +LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT +ethernet lan connector +0 +16 +15 +Connector_RJ +RJ45_Wuerth_7499151120_Horizontal +Wuerth 7499151120, LAN-Transformer WE-RJ45LAN 10/100/1000 BaseT, Dual Ethernet Jack (http://katalog.we-online.de/pbs/datasheet/7499151120.pdf) +ethernet lan connector +0 +32 +29 +Connector_RJ +RJ45_Wuerth_74980111211_Horizontal +RJ45 LAN Transformer 10/100BaseT (https://katalog.we-online.de/pbs/datasheet/74980111211.pdf) +lan magnetics transformer +0 +14 +13 +Connector_SATA_SAS +SAS-mini_TEConnectivity_1888174_Vertical +36pin mini SAS connector, http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=1888174&DocType=Customer+Drawing&DocLang=English +SAS mini connector +0 +44 +44 +Connector_SATA_SAS +SATA_Amphenol_10029364-001LF_Horizontal +https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10029364.pdf +SATA +0 +24 +23 +Connector_Samtec +Samtec_FMC_ASP-134486-01_10x40_P1.27mm_Vertical +http://suddendocs.samtec.com/prints/asp-134486-01-mkt.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134602-01_10x40_P1.27mm_Vertical +https://www.marutsu.co.jp/contents/shop/marutsu/ds/asp-134602-01.pdf +FMC HPC +0 +400 +400 +Connector_Samtec +Samtec_FMC_ASP-134604-01_4x40_Vertical +http://www.samtec.com/standards/vita.aspx +FMC LPC VITA +0 +162 +160 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-N_2x05_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-N, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +10 +10 +Connector_Samtec +Samtec_LSHM-105-xx.x-x-DV-S_2x05-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-105-xx.x-x-DV-S, 5 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +12 +11 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-N_2x10_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-N, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +20 +20 +Connector_Samtec +Samtec_LSHM-110-xx.x-x-DV-S_2x10-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-110-xx.x-x-DV-S, 10 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +22 +21 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-N_2x20_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-N, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +40 +40 +Connector_Samtec +Samtec_LSHM-120-xx.x-x-DV-S_2x20-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-120-xx.x-x-DV-S, 20 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +42 +41 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-N_2x30_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-N, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +60 +60 +Connector_Samtec +Samtec_LSHM-130-xx.x-x-DV-S_2x30-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-130-xx.x-x-DV-S, 30 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +62 +61 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-N_2x40_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-N, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +80 +80 +Connector_Samtec +Samtec_LSHM-140-xx.x-x-DV-S_2x40-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-140-xx.x-x-DV-S, 40 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +82 +81 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-N_2x50_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-N, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +100 +100 +Connector_Samtec +Samtec_LSHM-150-xx.x-x-DV-S_2x50-1SH_P0.50mm_Vertical +Molex LSHM 0.50 mm Razor Beam High-Speed Hermaphroditic Terminal/Socket Strip, LSHM-150-xx.x-x-DV-S, 50 Pins per row (http://suddendocs.samtec.com/prints/lshm-1xx-xx.x-x-dv-a-x-x-tr-footprint.pdf), generated with kicad-footprint-generator +connector Samtec side entry +0 +102 +101 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE-LC_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE-LC, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-PE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-PE (compatible alternatives: HLE-104-02-xx-DV-PE-BE), 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-104-02-xx-DV-TE_2x04_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-104-02-xx-DV-TE, 4 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +8 +8 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE-LC_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE-LC, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-PE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-PE (compatible alternatives: HLE-105-02-xx-DV-PE-BE), 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-105-02-xx-DV-TE_2x05_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-105-02-xx-DV-TE, 5 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +10 +10 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE-LC_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE-LC, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-PE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-PE (compatible alternatives: HLE-106-02-xx-DV-PE-BE), 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-106-02-xx-DV-TE_2x06_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-106-02-xx-DV-TE, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +12 +12 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE-LC_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE-LC, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-PE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-PE (compatible alternatives: HLE-107-02-xx-DV-PE-BE), 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-107-02-xx-DV-TE_2x07_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-107-02-xx-DV-TE, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +14 +14 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE-LC_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE-LC, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-PE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE (compatible alternatives: HLE-108-02-xx-DV-PE-BE), 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-108-02-xx-DV-TE_2x08_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-TE, 8 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +16 +16 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE-LC_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE-LC, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-PE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE (compatible alternatives: HLE-109-02-xx-DV-PE-BE), 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-109-02-xx-DV-TE_2x09_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-TE, 9 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +18 +18 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE-LC_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE-LC, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-PE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-PE (compatible alternatives: HLE-110-02-xx-DV-PE-BE), 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-110-02-xx-DV-TE_2x10_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-110-02-xx-DV-TE, 10 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +20 +20 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE-LC_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE-LC, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-PE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-PE (compatible alternatives: HLE-111-02-xx-DV-PE-BE), 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-111-02-xx-DV-TE_2x11_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-TE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +22 +22 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE-LC_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE-LC, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-PE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-PE (compatible alternatives: HLE-112-02-xx-DV-PE-BE), 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-112-02-xx-DV-TE_2x12_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-112-02-xx-DV-TE, 12 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +24 +24 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE-LC_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE-LC, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-PE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-PE (compatible alternatives: HLE-113-02-xx-DV-PE-BE), 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-113-02-xx-DV-TE_2x13_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-TE, 13 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +26 +26 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE-LC_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE-LC, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-PE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-PE (compatible alternatives: HLE-114-02-xx-DV-PE-BE), 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-114-02-xx-DV-TE_2x14_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-114-02-xx-DV-TE, 14 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +28 +28 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE-LC_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE-LC, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-PE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-PE (compatible alternatives: HLE-115-02-xx-DV-PE-BE), 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-115-02-xx-DV-TE_2x15_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xx-DV-TE, 15 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +30 +30 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE-LC_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE-LC, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-PE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-PE (compatible alternatives: HLE-116-02-xx-DV-PE-BE), 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-116-02-xx-DV-TE_2x16_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-116-02-xx-DV-TE, 16 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +32 +32 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE-LC_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE-LC, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-PE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-PE (compatible alternatives: HLE-117-02-xx-DV-PE-BE), 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-117-02-xx-DV-TE_2x17_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-117-02-xx-DV-TE, 17 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +34 +34 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE-LC_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE-LC, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-PE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-PE (compatible alternatives: HLE-118-02-xx-DV-PE-BE), 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-118-02-xx-DV-TE_2x18_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-118-02-xx-DV-TE, 18 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +36 +36 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE-LC_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE-LC, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-PE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-PE (compatible alternatives: HLE-119-02-xx-DV-PE-BE), 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-119-02-xx-DV-TE_2x19_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-TE, 19 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +38 +38 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE-LC_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE-LC, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-PE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-PE (compatible alternatives: HLE-120-02-xx-DV-PE-BE), 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-120-02-xx-DV-TE_2x20_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-120-02-xx-DV-TE, 20 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +40 +40 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE-LC_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE-LC, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-PE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-PE (compatible alternatives: HLE-121-02-xx-DV-PE-BE), 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-121-02-xx-DV-TE_2x21_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-121-02-xx-DV-TE, 21 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +42 +42 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE-LC_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE-LC, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-PE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-PE (compatible alternatives: HLE-122-02-xx-DV-PE-BE), 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-122-02-xx-DV-TE_2x22_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-122-02-xx-DV-TE, 22 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +44 +44 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE-LC_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE-LC, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-PE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-PE (compatible alternatives: HLE-123-02-xx-DV-PE-BE), 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-123-02-xx-DV-TE_2x23_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-123-02-xx-DV-TE, 23 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +46 +46 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE-LC_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE-LC, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-PE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-PE (compatible alternatives: HLE-124-02-xx-DV-PE-BE), 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-124-02-xx-DV-TE_2x24_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-124-02-xx-DV-TE, 24 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +48 +48 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE-LC_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE-LC, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-PE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-PE (compatible alternatives: HLE-125-02-xx-DV-PE-BE), 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-125-02-xx-DV-TE_2x25_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-125-02-xx-DV-TE, 25 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +50 +50 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE-LC_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE-LC, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-PE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-PE (compatible alternatives: HLE-126-02-xx-DV-PE-BE), 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-126-02-xx-DV-TE_2x26_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-126-02-xx-DV-TE, 26 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +52 +52 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE-LC_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE-LC, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-PE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-PE (compatible alternatives: HLE-127-02-xx-DV-PE-BE), 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-127-02-xx-DV-TE_2x27_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-127-02-xx-DV-TE, 27 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +54 +54 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE-LC_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE-LC, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-PE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-PE (compatible alternatives: HLE-128-02-xx-DV-PE-BE), 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-128-02-xx-DV-TE_2x28_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xx-DV-TE, 28 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +56 +56 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE-LC_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE-LC, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-PE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-PE (compatible alternatives: HLE-129-02-xx-DV-PE-BE), 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-129-02-xx-DV-TE_2x29_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-129-02-xx-DV-TE, 29 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +58 +58 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE-LC_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE-LC, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-PE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-PE (compatible alternatives: HLE-130-02-xx-DV-PE-BE), 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-130-02-xx-DV-TE_2x30_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-130-02-xx-DV-TE, 30 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +60 +60 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE-LC_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE-LC, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-PE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-PE (compatible alternatives: HLE-131-02-xx-DV-PE-BE), 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-131-02-xx-DV-TE_2x31_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-131-02-xx-DV-TE, 31 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +62 +62 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE-LC_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE-LC, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-PE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-PE (compatible alternatives: HLE-132-02-xx-DV-PE-BE), 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-132-02-xx-DV-TE_2x32_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-132-02-xx-DV-TE, 32 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +64 +64 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE-LC_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE-LC, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-PE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-PE (compatible alternatives: HLE-133-02-xx-DV-PE-BE), 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-133-02-xx-DV-TE_2x33_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-133-02-xx-DV-TE, 33 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +66 +66 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE-LC_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE-LC, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-PE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-PE (compatible alternatives: HLE-134-02-xx-DV-PE-BE), 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-134-02-xx-DV-TE_2x34_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-134-02-xx-DV-TE, 34 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +68 +68 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE-LC_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE-LC, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-PE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-PE (compatible alternatives: HLE-135-02-xx-DV-PE-BE), 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-135-02-xx-DV-TE_2x35_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-135-02-xx-DV-TE, 35 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +70 +70 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE-LC_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE-LC, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-PE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-PE (compatible alternatives: HLE-136-02-xx-DV-PE-BE), 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-136-02-xx-DV-TE_2x36_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-136-02-xx-DV-TE, 36 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +72 +72 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE-LC_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE-LC, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-PE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-PE (compatible alternatives: HLE-137-02-xx-DV-PE-BE), 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-137-02-xx-DV-TE_2x37_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-137-02-xx-DV-TE, 37 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +74 +74 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE-LC_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE-LC, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-PE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-PE (compatible alternatives: HLE-138-02-xx-DV-PE-BE), 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-138-02-xx-DV-TE_2x38_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-138-02-xx-DV-TE, 38 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +76 +76 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE-LC_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE-LC, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-PE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-PE (compatible alternatives: HLE-139-02-xx-DV-PE-BE), 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-139-02-xx-DV-TE_2x39_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-139-02-xx-DV-TE, 39 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +78 +78 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE-LC_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE-LC, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-PE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-PE (compatible alternatives: HLE-140-02-xx-DV-PE-BE), 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-140-02-xx-DV-TE_2x40_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-140-02-xx-DV-TE, 40 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +80 +80 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE-LC_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE-LC, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-PE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-PE (compatible alternatives: HLE-141-02-xx-DV-PE-BE), 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-141-02-xx-DV-TE_2x41_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-141-02-xx-DV-TE, 41 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +82 +82 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE-LC_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE-LC, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-PE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-PE (compatible alternatives: HLE-142-02-xx-DV-PE-BE), 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-142-02-xx-DV-TE_2x42_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-142-02-xx-DV-TE, 42 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +84 +84 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE-LC_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE-LC, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-PE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-PE (compatible alternatives: HLE-143-02-xx-DV-PE-BE), 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-143-02-xx-DV-TE_2x43_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-143-02-xx-DV-TE, 43 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +86 +86 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE-LC_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE-LC, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-PE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-PE (compatible alternatives: HLE-144-02-xx-DV-PE-BE), 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-144-02-xx-DV-TE_2x44_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-144-02-xx-DV-TE, 44 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +88 +88 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE-LC_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE-LC, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-PE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-PE (compatible alternatives: HLE-145-02-xx-DV-PE-BE), 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-145-02-xx-DV-TE_2x45_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-145-02-xx-DV-TE, 45 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +90 +90 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE-LC_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE-LC, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-PE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-PE (compatible alternatives: HLE-146-02-xx-DV-PE-BE), 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-146-02-xx-DV-TE_2x46_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-146-02-xx-DV-TE, 46 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +92 +92 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE-LC_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE-LC, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-PE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-PE (compatible alternatives: HLE-147-02-xx-DV-PE-BE), 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-147-02-xx-DV-TE_2x47_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-147-02-xx-DV-TE, 47 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +94 +94 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE-LC_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE-LC, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-PE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-PE (compatible alternatives: HLE-148-02-xx-DV-PE-BE), 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-148-02-xx-DV-TE_2x48_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-148-02-xx-DV-TE, 48 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +96 +96 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE-LC_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE-LC, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-PE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-PE (compatible alternatives: HLE-149-02-xx-DV-PE-BE), 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-149-02-xx-DV-TE_2x49_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-149-02-xx-DV-TE, 49 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +98 +98 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE-LC_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE-LC, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-PE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-PE (compatible alternatives: HLE-150-02-xx-DV-PE-BE), 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_Samtec_HLE_THT +Samtec_HLE-150-02-xx-DV-TE_2x50_P2.54mm_Horizontal +Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-150-02-xx-DV-TE, 50 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator +connector Samtec HLE top entry +0 +100 +100 +Connector_USB +USB3_A_Molex_48393-001 +USB 3.0, type A, right angle (http://www.molex.com/pdm_docs/sd/483930003_sd.pdf) +USB 3.0 type A right angle +0 +13 +10 +Connector_USB +USB3_A_Plug_Wuerth_692112030100_Horizontal +USB3 type A Plug, Horizontal, http://katalog.we-online.de/em/datasheet/692112030100.pdf +usb A plug horizontal +0 +11 +10 +Connector_USB +USB_A_CNCTech_1001-011-01101_Horizontal +USB type A Plug, Horizontal, http://cnctech.us/pdfs/1001-011-01101.pdf +USB-A +0 +6 +5 +Connector_USB +USB_A_CONNFLY_DS1095-WNR0 +http://www.connfly.com/userfiles/image/UpLoadFile/File/2013/5/6/DS1095.pdf +USB-A receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_A_Molex_67643_Horizontal +USB type A, Horizontal, https://www.molex.com/pdm_docs/sd/676433910_sd.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Molex_105057_Vertical +https://www.molex.com/pdm_docs/sd/1050570001_sd.pdf +USB A Vertical +0 +7 +5 +Connector_USB +USB_A_Stewart_SS-52100-001_Horizontal +USB A connector https://belfuse.com/resources/drawings/stewartconnector/dr-stw-ss-52100-001.pdf +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_TE_292303-7_Horizontal +USB type A, Horizontal, https://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=292303&DocType=Customer+Drawing&DocLang=English +USB_A Female Connector receptacle +0 +6 +5 +Connector_USB +USB_A_Wuerth_614004134726_Horizontal +USB A connector https://www.we-online.com/catalog/datasheet/614004134726.pdf +USB_A Female Connector receptacle +0 +8 +5 +Connector_USB +USB_A_Wuerth_61400826021_Horizontal_Stacked +Stacked USB A connector http://katalog.we-online.de/em/datasheet/61400826021.pdf +Wuerth stacked USB_A +0 +12 +9 +Connector_USB +USB_B_Amphenol_MUSB-D511_Vertical_Rugged +A,phenol MUSB_D511, USB B female connector, straight, rugged, https://www.amphenolcanada.com/ProductSearch/drawings/AC/MUSBD511XX.pdf +USB_B_MUSB_Straight female connector straight rugged MUSB D511 +0 +6 +5 +Connector_USB +USB_B_Lumberg_2411_02_Horizontal +USB 2.0 receptacle type B, horizontal version, through-hole, https://downloads.lumberg.com/datenblaetter/en/2411_02.pdf +USB B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_OST_USB-B1HSxx_Horizontal +USB B receptacle, Horizontal, through-hole, http://www.on-shore.com/wp-content/uploads/2015/09/usb-b1hsxx.pdf +USB-B receptacle horizontal through-hole +0 +6 +5 +Connector_USB +USB_B_TE_5787834_Vertical +http://www.mouser.com/ds/2/418/NG_CD_5787834_A4-669110.pdf +USB_B USB B vertical female connector +0 +6 +5 +Connector_USB +USB_C_Plug_JAE_DX07P024AJ1 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, https://www.jae.com/en/searchfilter/?topics_keyword=DX07P024AJ1&mainItemSelect=1 +USB Type-C Plug Edge Mount +0 +30 +25 +Connector_USB +USB_C_Plug_Molex_105444 +Universal Serial Bus (USB) Shielded I/O Plug, Type C, Right Angle, Surface Mount, http://www.molex.com/pdm_docs/sd/1054440001_sd.pdf +USB Type-C Plug Edge Mount +0 +24 +23 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401548E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, Hybrid, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401548E4%7e2A +USB C Type-C Receptacle Hybrid +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Amphenol_12401610E4-2A_CircularHoles +USB TYPE C, RA RCPT PCB, SMT, https://www.amphenolcanada.com/StockAvailabilityPrice.aspx?From=&PartNum=12401610E4%7e2A +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_GCT_USB4085 +USB 2.0 Type C Receptacle, https://gct.co/Files/Drawings/USB4085.pdf +USB Type-C Receptacle Through-hole Right angle +0 +20 +17 +Connector_USB +USB_C_Receptacle_HRO_TYPE-C-31-M-12 +USB Type-C receptacle for USB 2.0 and PD, http://www.krhro.com/uploads/soft/180320/1-1P320120243.pdf +usb usb-c 2.0 pd +0 +20 +17 +Connector_USB +USB_C_Receptacle_JAE_DX07S016JA1R1500 +USB TYPE C, USB 2.0, SMT, https://www.jae.com/en/connectors/series/detail/product/id=91780 +USB C Type-C Receptacle SMD USB 2.0 +0 +22 +17 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ1R350 +http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117219.pdf +USB C Type-C Receptacle SMD +0 +30 +25 +Connector_USB +USB_C_Receptacle_JAE_DX07S024WJ3R400 +USB TYPE C, VERT RCPT PCB, SMT, http://www.jae.com/z-en/pdf_download_exec.cfm?param=SJ117928.pdf +USB C Type-C Receptacle SMD +0 +28 +25 +Connector_USB +USB_C_Receptacle_Palconn_UTC16-G +http://www.palpilot.com/wp-content/uploads/2017/05/UTC027-GKN-OR-Rev-A.pdf +USB C Type-C Receptacle USB2.0 +0 +20 +17 +Connector_USB +USB_C_Receptacle_XKB_U262-16XN-4BVC11 +USB Type C, right-angle, SMT, https://datasheet.lcsc.com/szlcsc/1811141824_XKB-Enterprise-U262-161N-4BVC11_C319148.pdf +USB C Type-C Receptacle SMD +0 +20 +17 +Connector_USB +USB_Micro-AB_Molex_47590-0001 +Micro USB AB receptable, right-angle inverted (https://www.molex.com/pdm_docs/sd/475900001_sd.pdf) +Micro AB USB SMD +0 +14 +6 +Connector_USB +USB_Micro-B_Amphenol_10103594-0001LF_Horizontal +Micro USB Type B 10103594-0001LF, http://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10103594.pdf +USB USB_B USB_micro USB_OTG +0 +17 +6 +Connector_USB +USB_Micro-B_Amphenol_10104110_Horizontal +USB Micro-B, horizontal, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10104110.pdf +USB Micro B horizontal +0 +9 +6 +Connector_USB +USB_Micro-B_Amphenol_10118194_Horizontal +USB Micro-B receptacle, horizontal, SMD, 10118194, https://cdn.amphenol-icc.com/media/wysiwyg/files/drawing/10118194.pdf +USB Micro B horizontal SMD +0 +17 +6 +Connector_USB +USB_Micro-B_GCT_USB3076-30-A +GCT Micro USB https://gct.co/files/drawings/usb3076.pdf +Micro-USB SMD Typ-B GCT +0 +11 +6 +Connector_USB +USB_Micro-B_Molex-105017-0001 +http://www.molex.com/pdm_docs/sd/1050170001_sd.pdf +Micro-USB SMD Typ-B +0 +13 +6 +Connector_USB +USB_Micro-B_Molex-105133-0001 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330001_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex-105133-0031 +Molex Vertical Micro USB Typ-B (http://www.molex.com/pdm_docs/sd/1051330031_sd.pdf) +Micro-USB SMD Typ-B Vertical +0 +8 +6 +Connector_USB +USB_Micro-B_Molex_47346-0001 +Micro USB B receptable with flange, bottom-mount, SMD, right-angle (http://www.molex.com/pdm_docs/sd/473460001_sd.pdf) +Micro B USB SMD +0 +11 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_614105150721_Vertical_CircularHoles +USB Micro-B receptacle, through-hole, vertical, http://katalog.we-online.de/em/datasheet/614105150721.pdf +usb micro receptacle vertical +0 +7 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521 +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Micro-B_Wuerth_629105150521_CircularHoles +USB Micro-B receptacle, http://www.mouser.com/ds/2/445/629105150521-469306.pdf +usb micro receptacle +0 +9 +6 +Connector_USB +USB_Mini-B_AdamTech_MUSB-B5-S-VT-TSMT-1_SMD_Vertical +http://www.adam-tech.com/upload/MUSB-B5-S-VT-TSMT-1.pdf +USB Mini-B +0 +7 +6 +Connector_USB +USB_Mini-B_Lumberg_2486_01_Horizontal +USB Mini-B 5-pin SMD connector, http://downloads.lumberg.com/datenblaetter/en/2486_01.pdf +USB USB_B USB_Mini connector +0 +9 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Tensility_54-00023_Vertical_CircularHoles +http://www.tensility.com/pdffiles/54-00023.pdf +usb mini receptacle vertical +0 +7 +6 +Connector_USB +USB_Mini-B_Wuerth_65100516121_Horizontal +Mini USB 2.0 Type B SMT Horizontal 5 Contacts (https://katalog.we-online.de/em/datasheet/65100516121.pdf) +Mini USB 2.0 Type B +0 +9 +6 +Connector_Wago +Wago_734-132_1x02_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-132 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +2 +2 +Connector_Wago +Wago_734-133_1x03_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-133 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +3 +3 +Connector_Wago +Wago_734-134_1x04_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-134 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +4 +4 +Connector_Wago +Wago_734-135_1x05_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-135 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +5 +5 +Connector_Wago +Wago_734-136_1x06_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-136 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +6 +6 +Connector_Wago +Wago_734-137_1x07_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-137 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +7 +7 +Connector_Wago +Wago_734-138_1x08_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-138 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +8 +8 +Connector_Wago +Wago_734-139_1x09_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-139 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +9 +9 +Connector_Wago +Wago_734-140_1x10_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-140 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +10 +10 +Connector_Wago +Wago_734-141_1x11_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-141 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +11 +11 +Connector_Wago +Wago_734-142_1x12_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-142 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +12 +12 +Connector_Wago +Wago_734-143_1x13_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-143 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +13 +13 +Connector_Wago +Wago_734-144_1x14_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-144 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +14 +14 +Connector_Wago +Wago_734-146_1x16_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-146 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +16 +16 +Connector_Wago +Wago_734-148_1x18_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-148 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +18 +18 +Connector_Wago +Wago_734-150_1x20_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-150 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +20 +20 +Connector_Wago +Wago_734-154_1x24_P3.50mm_Vertical +Molex 734 Male header (for PCBs); Straight solder pin 1 x 1 mm, 734-154 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago side entry +0 +24 +24 +Connector_Wago +Wago_734-162_1x02_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-162 , 2 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +2 +2 +Connector_Wago +Wago_734-163_1x03_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-163 , 3 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +3 +3 +Connector_Wago +Wago_734-164_1x04_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-164 , 4 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +4 +4 +Connector_Wago +Wago_734-165_1x05_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-165 , 5 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +5 +5 +Connector_Wago +Wago_734-166_1x06_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-166 , 6 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +6 +6 +Connector_Wago +Wago_734-167_1x07_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-167 , 7 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +7 +7 +Connector_Wago +Wago_734-168_1x08_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-168 , 8 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +8 +8 +Connector_Wago +Wago_734-169_1x09_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-169 , 9 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +9 +9 +Connector_Wago +Wago_734-170_1x10_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-170 , 10 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +10 +10 +Connector_Wago +Wago_734-171_1x11_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-171 , 11 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +11 +11 +Connector_Wago +Wago_734-172_1x12_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-172 , 12 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +12 +12 +Connector_Wago +Wago_734-173_1x13_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-173 , 13 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +13 +13 +Connector_Wago +Wago_734-174_1x14_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-174 , 14 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +14 +14 +Connector_Wago +Wago_734-176_1x16_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-176 , 16 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +16 +16 +Connector_Wago +Wago_734-178_1x18_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-178 , 18 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +18 +18 +Connector_Wago +Wago_734-180_1x20_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-180 , 20 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +20 +20 +Connector_Wago +Wago_734-184_1x24_P3.50mm_Horizontal +Molex 734 Male header (for PCBs); Angled solder pin 1 x 1 mm, 734-184 , 24 Pins (http://www.farnell.com/datasheets/2157639.pdf), generated with kicad-footprint-generator +connector Wago top entry +0 +24 +24