unified_retro_keyboard/hardware/interface-ascii/bom.ini

125 lines
4.1 KiB
INI
Raw Normal View History

[BOM_OPTIONS]
; General BoM options here
; If 'ignore_dnf' option is set to 1, rows that are not to be fitted on the PCB will not be written to the BoM file
ignore_dnf = 0
; If 'html_generate_dnf' option is set to 1, also generate a list of components not fitted on the PCB (HTML only)
html_generate_dnf = 1
; If 'use_alt' option is set to 1, grouped references will be printed in the alternate compressed style eg: R1-R7,R18
use_alt = 1
; If 'alt_wrap' option is set to and integer N, the references field will wrap after N entries are printed
alt_wrap = 0
; If 'number_rows' option is set to 1, each row in the BoM will be prepended with an incrementing row number
number_rows = 1
; If 'group_connectors' option is set to 1, connectors with the same footprints will be grouped together, independent of the name of the connector
group_connectors = 1
; If 'test_regex' option is set to 1, each component group will be tested against a number of regular-expressions (specified, per column, below). If any matches are found, the row is ignored in the output file
test_regex = 1
; If 'merge_blank_fields' option is set to 1, component groups with blank fields will be merged into the most compatible group, where possible
merge_blank_fields = 1
; Specify output file name format, %O is the defined output name, %v is the version, %V is the variant name which will be ammended according to 'variant_file_name_format'.
output_file_name = %O_bom_%v%V
; Specify the variant file name format, this is a unique field as the variant is not always used/specified. When it is unused you will want to strip all of this.
variant_file_name_format = _(%V)
; Field name used to determine if a particular part is to be fitted
fit_field = Fitted
; Make a backup of the bom before generating the new one, using the following template
make_backup = %O.tmp
; Default number of boards to produce if none given on CLI with -n
number_boards = 1
; Default PCB variant if none given on CLI with -r
board_variant = ['default']
; Whether to hide headers from output file
hide_headers = False
; Whether to hide PCB info from output file
hide_pcb_info = False
[IGNORE_COLUMNS]
; Any column heading that appears here will be excluded from the Generated BoM
; Titles are case-insensitive
Class
Component Type
Footprint
Footprint Lib
Material
Number of Pins
Package Variant
Part
Part Lib
Power Rating
RoHS China Link
RoHS Europe Link
SheetPath
Standards Version
Temp (Operating)
Temp (Soldering)
Temp (Storage)
Temp Coeff.
Tolerance
Value
Voltage Rating
Current Rating
[COLUMN_ORDER]
; Columns will apear in the order they are listed here
; Titles are case-insensitive
References
Fitted
Quantity Per PCB
Description
Part Value
Manufacturer
Manufacturer PN
Label
BOM Comment
[GROUP_FIELDS]
; List of fields used for sorting individual components into groups
; Components which match (comparing *all* fields) will be grouped together
; Field names are case-insensitive
Part
Part Lib
Value
Footprint
Footprint Lib
[COMPONENT_ALIASES]
; A series of values which are considered to be equivalent for the part name
; Each line represents a list of equivalent component name values separated by white space
; e.g. 'c c_small cap' will ensure the equivalent capacitor symbols can be grouped together
; Aliases are case-insensitive
c c_small cap capacitor
r r_small res resistor
sw switch
l l_small inductor
zener zenersmall
d diode d_small
[REGEX_INCLUDE]
; A series of regular expressions used to include parts in the BoM
; If there are any regex defined here, only components that match against ANY of them will be included in the BOM
; Column names are case-insensitive
; Format is: "[ColumName] [Regex]" (white-space separated)
[REGEX_EXCLUDE]
; A series of regular expressions used to exclude parts from the BoM
; If a component matches ANY of these, it will be excluded from the BoM
; Column names are case-insensitive
; Format is: "[ColumName] [Regex]" (white-space separated)
References ^TP[0-9]*
References ^FID
Part mount.*hole
Part solder.*bridge
Part test.*point
Footprint test.*point
Footprint mount.*hole
Footprint fiducial
Allow Substitution
Tracking
Package
Manufacturer Link
Component Value
Datasheet