Benoît Thébaudeau ba6a0bc381 enc28j60: Add workaround for erratum #2 "CLKRDY set early"
A delay of 1 ms must be added after the System Reset Command. Still wait
for ESTAT.CLKRDY afterwards as a precaution.

Signed-off-by: Benoît Thébaudeau <benoit.thebaudeau.dev@gmail.com>
2015-07-16 21:14:13 +02:00
..