1. Registry functions
The set of functions are changed to consistently use bool arguments.
The macros are changed to inline functions to improve type checking.
RegSaveValue() are overloaded with help of templates to reduce
typecasting at call sites. For instance, bool value would be converted
consistently instead of relying on call sites to convert bool to int values.
2. Memory functions
BOOL usages were unnecessary. Mostly internal usages which can simply be bool.
3. FrameBase
Some member variables are changed to bool.
BOOL was used because of those Registry functions.
Additional changes:
- Some expressions are forced to be bool when assigning to bool variables.
* Snapshot_GetDefaultFilenameAndPath(): fix segfault. SLOT7 -> i
* Disk & HardDisk: tidy up casts and iterations.
Signed-off-by: Andrea Odetti <mariofutire@gmail.com>
. On selecting a new card in a slot, then reset to the card's default options
. On opening Config dialog, reset config for empty slots
. On HDD insert: check for dup image-name against all other 7 units
. Add PropSheetPage: Slots (and include 'Reset to Default')
- include config options for some cards
. Remove PropSheetPages: Sound & Disk
. Config page: refactor and add 'Reset all to Default'
. Input page: refactor
. Advanced page: refactor
Better support the IIe's aux slot when it's empty or has the 80-col(1KiB) card.
- any h/w using this alternate CPU emulation, (ie. aux=empty or 80-col(1KiB)), then the 'mem' cache is completely bypassed.
Debugger: change all the direct 'mem' accesses to go via ReadByteFromMemory().
TestCPU6502: test the alt CPU emulation code too.
Support FORMAT cmd:
. HDC firmware: byte $FE, b3=1 (format supported)
. HDC firmware: allow both SmartPort and BLK FORMAT cmd (and check that SP FORMAT only has 1 parameter)
SmartPort Controller:
. Format will just zero all blocks (if not write-protected)
. Write cmd: if write-protected return NOWRITE
. SP Status cmd: 'General Status': set format-allowed & write-protected flags
If HDD image is read-only then support as write-protected.
. On Insert() setup m_bWriteProtected flag correctly
Added new SmartPort Harddisk Controller (HDC) firmware for Enhanced //e. (@burniouf)
. remove the old DOSMaster entrypoints.
. firmware ID byte (at $FE) defaults to 4 ProDOS block devices (was 2 with older v2 f/w).
Enhanced //e defaults to using SP f/w, and older Apple II's still use the older v2 f/w.
Support up to 8 units per HDC (currently limited to 4GiB capacity for each unit).
Save-state: save HDC firmware in state file.
New slot-specific switches to configure each HDC's firmware: -s<N> -hdc-[sp|bm2|bm4].
New switch to select old non-SP firmware for all HDCs: -hdc-firmware-v2.
* New command line option to force a size for autoexpanding use.
* New HDD Controller firmware uses a separate v2 name and folder.
* Harddisk.cpp now loads HDD Controller firmware v2 by default.
* Save-state for 'Generic HDD' bumped to v4
When the debugger is active (eg. breakpoints enabled) then trap on HDD r/w's that match the BPM[R|W].
NB. the breakpoint will fire after the whole HDD r/w operation has completed.
Support VidHD in slot 3 (via Config GUI or '-s3 vidhd') for SHR video modes only.
- AppleWin window is slightly enlarged when VidHD card is inserted.
Support IIgs 320x200 (and fill mode) and 640x200 video modes.
Debugger: add 'shr' command to view video
CUI: Allow user to specify width & height (for full-screen); and allow separate x,y scaling in full-screen mode.
. Add user-protection when unchecking HDD controller (as images aren't restored on a 'cancel')
. Fix possible crash when removing (via Config->Disk) either Disk2 card(s5) or HDD card(s7), then cancelling during emulation
. Fix m_buf[] size
Initially all cards are removed before loading save-state.
Use new Registry "Configuration/Slot 2" location to save SSC's port name.
Use new Registry "Configuration/Slot 7" location to save HDV's image names.
Use new Registry "Configuration/Slot n" (and "Configuration/Slot Auxiliary") locations to save all other card types.
Command line: -s<slot> (eg. -s7 empty) now get persisted to the Registry.
Only update 'HDV Starting Directory' for slot7 & drive1.