module CNT( /* FSB clock and E clock inputs */ input CLK, input E, /* Refresh request */ output reg RefReq, output reg RefUrg, /* Reset, button */ output reg nRESout, input nRESin, input nIPL2, /* Mac PDS bus master control outputs */ output reg AoutOE, output reg nBR_IOB, /* QoS control */ input BACT, input QoSCS, output reg QoSEN); /* E clock synchronization */ reg [1:0] Er; always @(posedge CLK) Er[1:0] <= { Er[0], E }; wire EFall = Er[1] && !Er[0]; /* NMI and reset synchronization */ reg nIPL2r; always @(posedge CLK) nIPL2r <= nIPL2; reg nRESr; always @(posedge CLK) nRESr <= nRESin; /* Startup sequence state */ reg [1:0] IS = 0; /* Timer counts from 0 to 1010 (10) -- 11 states == 14.042 us * Refresh timer sequence * | Timer | RefReq | RefUrg | * |---------|--------|-----------| * | 0 0000 | 0 | 0 | * | 1 0001 | 1 | 0 | * | 2 0010 | 1 | 0 | * | 3 0011 | 1 | 0 | * | 4 0100 | 1 | 0 | * | 5 0101 | 1 | 0 | * | 6 0110 | 1 | 0 | * | 7 0111 | 1 | 0 | * | 8 1000 | 1 | 0 | * | 9 1001 | 1 | 1 | * | 10 1010 | 1 | 1 | * back to timer==0 */ reg [3:0] Timer = 0; reg TimerTC; always @(posedge CLK) begin if (EFall) begin if (TimerTC) Timer <= 0; else Timer <= Timer+1; RefUrg <= Timer==8 || Timer==9; RefReq <= Timer!=10; TimerTC <= Timer==9; end end /* During init (IS!=3) long timer counts from 0 to 4095. * 4096 states == 57.516 ms */ reg [11:0] LTimer; reg LTimerTC; always @(posedge CLK) begin if (EFall && TimerTC) begin LTimer <= LTimer+1; LTimerTC <= LTimer[11:0]==12'hFFE; end end /* QoS select latch */ reg QoSCSr; always @(posedge CLK) if (BACT) QoSCSr <= QoSCS; /* QoS timer * In the absence of a QoS trigger, QS==0. * When Qos triggered, QS is set to 1 and counts 1, 2, 3, 0. * While QS!=0, QoS is enabled. * QoS enable period is 28.124 us - 42.240 us */ reg [1:0] QS; always @(posedge CLK) begin if (!nRESr || QoSCSr) QS[1:0] <= 1; else if (QS==0) QS[1:0] <= 0; else if (EFall && TimerTC) QS[1:0] <= QS+1; end /* QoS enable control */ always @(posedge CLK) if (!BACT) QoSEN <= QoSCSr || QS!=0; /* Startup sequence state control */ wire ISTC = EFall && TimerTC && LTimerTC; always @(posedge CLK) begin case (IS[1:0]) 0: begin AoutOE <= 0; // Tristate PDS address and control nRESout <= 0; // Hold reset low nBR_IOB <= 0; // Default to request bus if (ISTC) IS <= 1; end 1: begin AoutOE <= 0; nRESout <= 0; nBR_IOB <= !(!nBR_IOB && nIPL2r); // Disable bus request if NMI pressed if (ISTC && nIPL2r) IS <= 2; end 2: begin AoutOE <= !nBR_IOB; nRESout <= 0; if (ISTC) IS <= 3; end 3: begin nRESout <= 1; // Release reset IS <= 3; end endcase end endmodule