mirror of
https://github.com/fadden/6502bench.git
synced 2024-11-29 10:50:28 +00:00
Fix application of reloc info in data areas
The test wasn't correctly excluding instructions, so it was possible to create a situation where a two-byte data item had an instruction starting in the second byte. We also weren't checking the length of the instruction to ensure that it was wider than the reloc data. This could get weird for an immediate constant when the M/X flags are wrong. When in doubt, don't overwrite.
This commit is contained in:
parent
bc15178a8e
commit
f4fe3af050
@ -235,7 +235,10 @@ namespace Asm65 {
|
||||
/// (8-bit) accumulator.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// This is where we decide how to treat ambiguous status flags.
|
||||
/// This is (mostly) where we decide how to treat ambiguous status flags. We favor
|
||||
/// short flags because, when we get it wrong, it tends to be easier to spot (e.g.
|
||||
/// LDA #$00xx becomes LDA+BRK). Mistakenly guessing "long" also tends to result in
|
||||
/// instructions with other instructions embedded in them, which can be confusing.
|
||||
/// </remarks>
|
||||
public bool IsShortM {
|
||||
get {
|
||||
|
@ -225,6 +225,11 @@ namespace SourceGen {
|
||||
return IsInlineData && DataDescriptor != null;
|
||||
}
|
||||
}
|
||||
public bool IsUntyped {
|
||||
get {
|
||||
return !IsInstruction && !IsData && !IsInlineData;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Get the target memory address for this byte.
|
||||
|
@ -165,11 +165,16 @@ namespace SourceGen {
|
||||
// Check for a relocation. It'll be at offset+1 because it's on the operand,
|
||||
// not the opcode byte. (Make sure to check the length, or an RTS followed
|
||||
// by relocated data will freak out.)
|
||||
//
|
||||
// We don't check for embedded instructions here. If that did somehow happen,
|
||||
// it's probably intentional, so we should do the replacement.
|
||||
//
|
||||
// TODO(someday): this won't get the second byte of an MVN/MVP, which is fine
|
||||
// since we don't currently support two formats on one instruction.
|
||||
if (mAnalysisParams.UseRelocData) {
|
||||
if (attr.Length > 1 && mProject.RelocList.TryGetValue(offset + 1,
|
||||
out DisasmProject.RelocData reloc)) {
|
||||
out DisasmProject.RelocData reloc) &&
|
||||
attr.Length > reloc.Width) {
|
||||
// The relocation address differs from what the analyzer came up
|
||||
// with. This may be because of incorrect assumptions about the
|
||||
// bank (assuming B==K) or because the partial address refers to
|
||||
@ -245,15 +250,15 @@ namespace SourceGen {
|
||||
// There shouldn't be any data items inside other data items, so we
|
||||
// can just skip forward.
|
||||
offset += mAnattribs[offset].DataDescriptor.Length - 1;
|
||||
} else if (mAnalysisParams.UseRelocData &&
|
||||
!attr.IsInstruction && !attr.IsData && !attr.IsInlineData &&
|
||||
} else if (mAnalysisParams.UseRelocData && attr.IsUntyped &&
|
||||
mProject.RelocList.TryGetValue(offset,
|
||||
out DisasmProject.RelocData reloc)) {
|
||||
// Byte is unformatted, but there's relocation data here. If the full
|
||||
// range of bytes is unformatted, create a symbolic reference.
|
||||
bool allClear = true;
|
||||
for (int i = 1; i < reloc.Width; i++) {
|
||||
if (mAnattribs[offset + i].DataDescriptor != null) {
|
||||
if (!mAnattribs[offset + i].IsUntyped ||
|
||||
mAnattribs[offset + i].DataDescriptor != null) {
|
||||
allClear = false;
|
||||
break;
|
||||
}
|
||||
@ -382,6 +387,8 @@ namespace SourceGen {
|
||||
// and offsets identified by users or scripts have been categorized.)
|
||||
//
|
||||
// ?? Can we use GetBaseOperandOffset(), which searches for IsStart?
|
||||
//
|
||||
// TODO(performance): we spend a significant amount of time in this loop.
|
||||
int scanOffset = targetOffset;
|
||||
while (--scanOffset >= 0) {
|
||||
FormatDescriptor dfd = mAnattribs[scanOffset].DataDescriptor;
|
||||
|