Copied the extension script tutorial files out of the Scripts
directory and into the Tutorial directory. This makes more sense,
and makes it possible to expand the script sample without altering
the tutorial.
Reverted the Scripts sample to be an actual sample, rather than a
tutorial.
Renumbered the last two tutorials and added them to the ToC. This
gives them actual numbers rather than treating them as add-ons to
the advanced tutorial.
Moved the source files for the tutorial binaries into a subdirectory
to reduce clutter.
This does mean we have two separate copies of the inline string
sample plugins, but that's an artifact of our attempts at security.
The code that found a nearby data target for an instruction operand
was searching backward but not forward. We now take one step
forward, so that "LDA TABLE-1,Y" fills in automatically.
This altered 2008-address-changes, which had just this situation.
It didn't alter 2010-target-adjustment, but the existing tests were
insufficient and have been improved.
The fix for Shift+F3 required briefly switching the code list view
to single-select mode. Unfortunately, while in that mode the
control throws an exception if you touch SelectedItems (plural)
rather than SelectedItem (singular), and in an unusual case the
selection-changed event handler was doing just that.
If a local variable table gets buried, it won't appear in the code
list, so most things ignore it. Unfortunately, the code that adds
new entries and edits tables was finding them, which was causing
variable definitions to appear to fall into a black hole.
This is addressed in two ways. First, we now add a message to the
log when a hidden table is noticed. Second, the code that finds
the nearest prior table now keeps track of hidden vs. not hidden.
If a non-hidden table is available, that is returned. If the only
option is a hidden table, we will return that, because the callers
have already assumed that a table exists by virtue of its presence
in the LvTable list.
Project symbol address values are now limited to positive 24-bit
integers, just as they are for platform symbols. Constants may
still be 32-bit values.
While disassembling some code I found that I wanted the ROM entry
points, but the zero page usage was significantly different and the
ROM labels were distracting. Splitting the symbol file in two was
a possibility, but I'm afraid this will lead to a very large
collection of very small files, and we'll lose any sense of relation
between the ROM entry points and the ZP addresses used to pass
arguments.
Platform symbols have the lowest priority when resolving by address,
but using that to hide the unwanted labels requires creating project
symbols or local variables for things that you might not know what
they do yet. It's possible to hide a platform symbol by adding
another symbol with the same label and an invalid value.
This change formalizes and extends the "hiding" of platform symbols
to full erasure, so that they don't clutter up the symbol table.
This also tightens up the platform symbol parser to only accept
values in the range 0 <= value <= 0x00ffffff (24-bit positive
integers).
An "F8-ROM-nozp" symbol file is now part of the standard set. A
project can include that to erase the zero-page definitions.
(I'm not entirely convinced this is the right approach, so I'm not
doing this treatment on other symbol files... consider this an
experiment. Another approach would be some sort of conditional
inclusion, or perhaps erase-by-tag, but that requires some UI work
in the app to define what you want included or excluded.)
- Allow user to "unnecessarily" set an address override. This is
a handy thing to do when dealing with code that does a lot of
relocations.
- Moved "save needed" text to the end of the title string.
- Updated F8-ROM syms.
- Added ProDOS 8 error code constants
If we detect a problem that requires intervention during loading,
e.g. we find unknown elements because we're loading a file created
by a newer version, default to read-only mode.
Read only mode (1) refuses to apply changes, (2) refuses to add
changes to the undo/redo list, and (3) disables Save/SaveAs. The
mode is indicated in the title bar.
Also, flipped the order of items in the title bar so that "6502bench
SourceGen" comes last. This allows you to read the project name in
short window title snippets. (Visual Studio, Notepad, and others
do it this way as well.)
While adding a message log entry for failing alignment directives,
I noticed that the assembler source generator's test for valid
alignment was allowing some bad alignment values through.
I'm holding off on reporting the message to the log because not all
format changes cause a data-reanalysis, which means the log entry
doesn't always appear and disappear when it should. If we decide
this is an important message we can add a scan for "softer" errors.
In the assembler output, add a blank line between the constants
and addresses in the long list of equates.
The earlier change that corrected the BIT instruction caused test
2009-branches-and-banks to fail, because it was relying on the idea
that BIT made the carry flag indeterminate. Changing a BCC to a
BVS restored the desired behavior.
Not a huge improvement, but things are slightly more organized, and
there's a splash of color in the form of a border around the text
describing the format of code and data lines.
Added an "IsConstant" property to Symbol.
Sometimes code relocates a few bits of itself but not others. We
don't currently have a way to say, "go back to where we would have
been". As a cheap alternative, we now show the "load address", i.e.
where we'd be if there were no address map entries after the first.
The "affected flags" constants were incorrect for BIT, BRK, COP,
RTI, XCE, and the undocmented instructions ANE, DCP, and SAX. The
constants are used for the changed-flag summary shown in the info
window and the instruction chart.
Of greater import: the status flag updater for BIT was incorrectly
marking N/V/C as indeterminate instead of N/V/Z. The undocmented
instructions ANE, DCP, and SAX were also incorrect.
The cycle counts shown in line comments are computed correctly, but
the counts shown in the info window and instruction chart were
displaying the full set of modifiers, ignoring the CPU type. That's
okay for the info window, which spells the modifiers out, though
it'd be better if the bits were explicitly marked as being applicable
to the current CPU or a different one.
Mark the "info" window as read-only.
When the project closes, clear the contents of the Symbols and
Notes windows.
Clarify some Apple II I/O definitions.
This adds a window that displays all of the instructions for a
given CPU in a summary grid. Undocumented instructions are
included, but shown in grey italics.
Also, tweaked AppSettings to not mark itself as dirty if a "set"
operation doesn't actually change anything.
Implemented show/hide mechanic, using a button on the right side of
the status bar to show status and to trigger un-hide.
Also, show I/O direction in project symbols editor list.
This converts the "problem list viewer" tool to a grid that appears
below the code list view when non-empty. Not all messages are
problems, so it's being renamed to "message list".
Created a Navigate menu, and put the menu items for Find and Go To
in it. Added menu items for nav-forward and nav-backward, which
until now were only available as toolbar buttons.
This began with a change to support "BRK <operand>" in cc65. The
assembler only supports this for 65816 projects, so we detect that
and enable it when available.
While fiddling with some test code an assertion fired. This
revealed a minor issue in the code analyzer: when overwriting inline
data with instructions, we weren't resetting the format descriptor.
The code that exercises it, which requires two-byte BRKs and an
inline BRK handler in an extension script, has been added to test
2022-extension-scripts.
The new regression test revealed a flaw in the 64tass code
generator's character encoding scanner that caused it to hang.
Fixed.
Sometimes there's a bunch of junk in the binary that isn't used for
anything. Often it's there to make things line up at the start of
a page boundary.
This adds a ".junk" directive that tells the disassembler that it
can safely disregard the contents of a region. If the region ends
on a power-of-two boundary, an alignment value can be specified.
The assembly source generators will output an alignment directive
when possible, a .fill directive when appropriate, and a .dense
directive when all else fails. Because we're required to regenerate
the original data file, it's not always possible to avoid generating
a hex dump.
Sort of silly to have every handler immediately pull the operand out
of the file data. (This is arguably less efficient, since we now
have to serialize the argument across the AppDomain boundary, but
we should be okay spending a few extra nanoseconds here.)
Memory-mapped I/O locations can have different behavior when read
vs. written. This is part 1 of a change to allow two different
symbols to represent the same address, based on I/O direction.
This also adds a set of address masks for systems like the Atari
2600 that map hardware addresses to multiple locations.
This change updates the data structures, .sym65 file reader,
project serialization, and DefSymbol editor.
We were failing to update properly when a label changed if the label
was one that a plugin cared about. The problem is that a label
add/remove operation skips the code analysis, and a label edit skips
everything but the display update. Plugins only run during the code
analysis pass, so changes weren't being reflected in the display
list until something caused it to refresh.
The solution is to ask the plugin if the label being changed is one
that it cares about. This allows the plugin to use the same
wildcard-match logic that it uses elsewhere.
For efficiency, and to reduce clutter in plugins that don't care
about symbols, a new interface class has been created to handle the
"here are the symbols" call and the "do you care about this label"
call.
The program in Examples/Scripts has been updated to show a very
simple single-call plugin and a slightly more complex multi-call
plugin.
Test case:
1. create a label FOO
(can be referenced or unreferenced)
2. add a platform symbol file that also defines FOO
(the platform symbol will be masked by the user label)
3. rename FOO to BAR
(platform symbol should appear)
4. hit "undo"
(platform symbol should disappear)
5. delete label FOO
(platform symbol should appear)
6. hit "undo"
(platform symbol should disappear)
This will fail to update the display list properly, and/or crash
when we try to add FOO to a symbol table that already has a
symbol with that label.
The problem is the optimization that tries to avoid running the
data analysis pass if we're just renaming a user label. We need to
check to see if the rename overlaps with project/platform symbols,
because we need to update the active def symbol set in that case.
To avoid the crash, we just need to use table[key]=value syntax
instead of table.Add(key,value).
Most of SourceGen uses standard WPF controls, which get their default
style from the system theme. The main disassembly list uses a
custom style, and always looks like the Windows default theme.
Some people greatly prefer white text on a black background, so we
now provide a way to get that. This also requires muting the colors
used for Notes, since those were chosen to contrast with black text.
This does not affect anything other than the ListView used for
code, because everything else can be set through the Windows
"personalization" interface. We might want to change the way the
Notes window looks though, to avoid having glowing bookmarks on
the side.
The last two tabs in the Edit App Settings dialog have "quick set"
buttons configure all fields for a particular assembler, or reset
them to default values. The previous UI was a little annoying,
because you had to pick something from the combo box and then hit
"set" to push the change. It was also confusing, because if you
came back later the combo box was just set to the first entry, not
the thing you picked last.
Now, picking an entry from the combo box immediately updates all
fields. The combo box selection is set to reflect the actual
contents (so if you set everything just right, the combo box will
change to a specific assembler). If nothing matches, a special
entry labeled "Custom" is selected.
Also, rearranged the tutorial sections in the manual so the
address table formatting comes last, and appears in the local TOC.
If you link to the file without escaping the '#', the browser will
think it's an anchor inside the page. Easier on everyone to just
alter the filename.
Changed the sort order on EQU lines so that constants come before
address definitions. This caused trivial changes to three of the
regression tests.
Added the ability to jump directly to an EQU line when an opcode
is double-clicked on.
If you select a local variable, double-click on a reference entry,
and then hit "back", you aren't taken back to the correct place in
the local variable table. This is annoying if you're trying to
explore how a local variable is used.
The NavStack Location object now has a "line delta" that can be
applied to position the selection correctly. This isn't stable
across undo/redo, but it solves the common cases.
This makes LineListGen's "Top" class redundant, so uses of that have
been replaced with Location.