# BlueSCSI 1.0-b to 1.0-c
:toc: macro
## Introduction
2022-06-17 11:52:11 +00:00
1.0-c was a small change to fix an issue with machines that provide low or no `TERMPOWER` over the SCSI bus. If you received a fully-assembled BlueSCSI after April 1st, 2021 then this was done for you. If you have a kit labeled 1.0-b you can make these modifications to become a 1.0-c.
2021-04-03 19:43:12 +00:00
## Steps
2022-06-17 11:52:11 +00:00
### Disconnect `TERMPOWER` from 220 Pull Up Jumper
2021-04-03 19:43:12 +00:00
Use a cutting tool to cut the small trace between the `TERMPOWR` and 220 Pull Up Jumper pictured below.
2022-06-17 11:52:11 +00:00
Make sure continuity from `TERMPOWER` to the diode still flows correctly but is disconnected from the jumper.
2021-04-03 19:43:12 +00:00
image::images/1.0-b-bodge-1.jpg[]
2022-06-17 11:52:11 +00:00
### Connect 5V to 220 Pull Up Jumper
2021-04-03 19:43:12 +00:00
2022-06-17 11:52:11 +00:00
Now we will provide pull up from the 5V provided by the BluePill.
2021-04-03 19:43:12 +00:00
image::images/1.0-b-bodge-2.png[]
### Complete!
2022-06-17 11:52:11 +00:00
Thats it! 5V to the Pull Up resistors will now work when powered externally.